首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Summary Three rice (Oryza sativa L.) mutants resistant to hydroxy-L-proline (Hyp), HYP 101, HYP 202 and HYP 203, were selected from an ethylene imine mutagenized M2 population of the original variety, Nipponbare, and their biochemical and genetical characteristics were investigated. The sensitivity of the mutants to Hyp could be clearly differentiated from that of the original variety when seeds were germinated and cultured with 10–410–3 M Hyp for 10 days. A difference in Hyp sensitivity was also observed among the HYP mutant lines, HYP 101 being the most resistant line. When free amino acids in seeds and 15-day-old seedlings were analyzed, the composition of the amino acids in the mutants was somewhat different from that found in the original variety. However, free proline accumulation was not detected in either the HYP mutants or the original variety. In each mutant line, HYP resistance was transmitted with a single recessive nuclear gene (hpr). These results suggest that the mechanism of Hyp resistance controlled by the recessive gene do not involve free proline accumulation.Abbreviations Hyp hydroxy-L-proline - T-Pro thioproline  相似文献   

2.
A high-performance liquid chromatographic method for the analysis of hydroxyproline and proline has been developed. The method is based on the derivatization of the secondary amino group with dabsyl-chloride after blocking of the primary amino group with o-phthalaldehyde. Dabsyl-hydroxyproline and dabsyl-proline were separated from other amino acids by high-performance liquid chromatography in the gradient elution mode, and eluted at 10.27 and 16.02 min, respectively. The correlations between the peak areas of dabsyl-hydroxyproline and dabsyl-proline were linear in the range from 20–200 pmol, with equations y = 1.10x − 0.80 (r = 0.999) and y = 1.12x − 0.52 (r = 0.999), respectively. The method was applied to the analysis of rat tail collagen, and the contents of hydroxyproline and proline were 1.55 ± 0.04 and 2.03 ± 0.04 nmol/μg, respectively.  相似文献   

3.
This paper describes a simple high-performance liquid chromatographic method for the determination of PGT/1A (3- -pyroglutamyl- -thiazolidine-4-carboxylic acid), a new immunostimulating drug, in plasma and urine. The column was packed with LiChrospher-NH2 (5 μm), the mobile phase was 0.02 M monobasic potassium phosphate (pH 3.2 with concentrated phosphoric acid)—acetonitrile (25:75, v/v), the flow-rate was 1.2 ml/min, the detection wavelength was 210 nm and the apparatus was a Varian Model 5000. Plasma (1 ml) was added to 1.2 ml of acetonitrile and the supernatant injected; the urine was diluted 1:5. The retention time of PGT/1A was 9.4 min in plasma and 9.9 min in urine. The method was validated for recovery, accuracy and reproducibility. The results after intravenous injection in twelve volunteers are also given.  相似文献   

4.
A rapid and simple high-performance liquid chromatographic method with amperometric detection has been developed for the quantitation of cilazapril and its active metabolite and degradation product cilazaprilat in urine and tablets. The chromatographic system consisted of a μBondapak C18 column, using a mixture of methanol–5 mM phosphoric acid (50:50, v/v) as mobile phase, which was pumped at a flow-rate of 1.0 ml/min. The column was kept at a constant temperature of (40±0.2)°C. Detection was performed using a glassy carbon electrode at a potential of 1350 mV. Sample preparation for urine consisted of a solid-phase extraction using C8 cartridges. This procedure allowed recoveries greater than 85% for both compounds. The method proved to be accurate, precise and sensitive enough to be applied to pharmacokinetic studies and it has been applied to urine samples obtained from four hypertensive patients (detection limit of 50 ng/ml for cilazapril and 40 ng/ml for cilazaprilat in urine). Results were in good agreement with pharmacokinetic data.  相似文献   

5.
A high-performance liquid chromatographic method with fluorescence detection for the determination of methamphetamine and its related compounds is reported. Methamphetamine, amphetamine, norephedrine, p-hydroxymethamphetamine and 1-phenylethylamine as an internal standard were extracted from human urine, derivatized with fluorescein-4-isothiocyanate, and then separated on a reversed-phase column within 36 min. The fluorescence intensity of the effluent was monitored at excitation and emission wavelengths of 496 and 518 nm, respectively. Calibration curves were confirmed to be linear up to at least 100 pmol on the column with a correlation coefficient (r) of 0.994–0.999 for the target compounds. The detection limits (S/N=3) were 55–105 fmol per 20-μl injection. The method was successfully applied to urine samples taken from methamphetamine addicts.  相似文献   

6.
Manual and automated determination of

This paper describes the determination of

and its metabolite (E)-5-(2-bromovinyl)uracil in urine. The method involves sample clean-up by liquid-liquid extraction with ethyl acetate followed by high-performance liquid chromatographic (HPLC) analysis. The sample preparation may be performed either manually or automatically using a Zymark Py-robotic system. The chloro analog of the parent compound, CV-araU, is used as the internal standard. As low as 0.1 μg of analyte per ml of urine can be measured. This sensitivity is adequate for pharmacokinetic studies but could be improved quite easily if necessary.  相似文献   

7.
A reversed-phase high-performance liquid chromatographic assay for the analysis of γ-carboxyglutamic acid (Gla) in urine and bone protein hydrolyzates is described. The method employs precolumn derivatization with o-phthalaldehyde and mercaptoethanol. Gla was quantified by reference to an internal standard (β-carboxyaspartic acid). The “within-run” coefficient of variation of the assay for Gla in urine was between 2.1 and 3.4%, and that for bone protein hydrolyzates was 3.2%. The “between-run” coefficient of variation ranged from 4.1 to 5.5%. There was good agreement between the measurement of urinary Gla by high-performance liquid chromatography and amino acid analyzer. Free Gla could not be detected in serum.  相似文献   

8.
A sensitive and reproducible assay for the determination of chymotrypsin-like esterase activity is reported. This method is based on fluorimetric detection of a dansylated amino acid, 5-dimethylaminonaphthalene-1-sulfonyl- -phenylalanine, enzymatically formed from the substrate 5-dimethylaminonaphthalene-1-sulfonyl- -phenylalanine ethyl ester, after separation by high-performance liquid chromatography using a C18 reversed-phase column and isocratic elution. This method is sensitive enough to measure 5-dimethylaminonaphthalene-1-sulfonyl- -phenylalanine at concentrations as low as 40 pmol/ml, yields highly reproducible results and requires less than 9.5 min per sample for quantitation. The optimum pH for chymotrypsin-like esterase activity was 7.7–8.3. The Km and Vmax values were, respectively 25 μM and 0.241 pmol/μg protein/h with the use of enzyme extract obtained from mouse kidney. The approximate molecular mass of this enzyme was estimated to be 67 000 by gel filtration. Chymotrypsin-like esterase activity was strongly inhibited by N-tosyl- -phenylalaline chloromethyl ketone. Among the mouse organs examined, the highest specific activity of the enzyme was found in lung. This new method would be useful for clarification of the physiological role of this enzyme.  相似文献   

9.
A high-performance liquid chromatographic method was developed for the determination of a new non-narcotic analgesic, DA-5018 (I), in rat plasma, urine and bile samples, using propranolol for plasma samples and protriptyline for urine and bile samples as internal standards. The method involved extraction followed by injection of 100 μl of the aqueous layer onto a C18 reversed-phase column. The mobile phases were 5 mM methanesulfonic acid with 10 mM NaH2PO4 (pH 2.5)-acetonitrile, 70:30 (v/v) for plasma samples and 75:25 (v/v) for urine and bile samples. The flow-rates were 1.0 ml/min for plasma samples and 1.2 ml/min for urine and bile samples. The column effluent was monitored by a fluorescence detector with an excitation wavelength of 270 nm and an emission wavelength of 330 nm. The retention time for I was 4.8 min in plasma samples and 10.0 min in urine and bile samples. The detection limits for I in rat plasma, urine and bile were 20, 100 and 100 ng/ml, respectively. There was no interference from endogenous substances.  相似文献   

10.
A simple, rapid and reproducible reversed-phase high-performance liquid chromatographic method for the simultaneous determination of benzoic acid (BA), phenylacetic acid (PAA) and their respective glycine conjugates hippuric acid (HA) and phenaceturic acid (PA) in sheep urine is described. The procedure involves only direct injection of a diluted urine sample, thus obviating the need for an extraction step or an internal standard. The compounds were separated on a Nova-Pak C18 column with isocratic elution with acetate buffer (25 mM, pH 4.5)—methanol (95:5). A flow-rate of 1.0 ml/min, a column temperature of 35°C and detection at 230 nm were employed. These conditions were optimized by investigating the effects of pH, molarity, methanol concentration in the mobile phase and column temperature on the resolution of the metabolites. The total analysis time was less than 15 min per sample. At a signal-to-noise ratio of 3 the detection limits for ten-fold diluted urine were 1.0 μg/ml for BA and HA and 5.0 μg/ml for PAA and PA with a 20-μl injection.  相似文献   

11.
A method for the determination of urinary

(M1) and

(M2) in man was developed. Clean-up of urine samples was obtained by a chromatographic technique using a short reversed-phase precolumn; purified samples were then deacetylated with porcine acylase I for 16 h at 37°C and deproteinized by centrifugal ultrafiltration. Derivatization was performed with o-phthaldialdehyde and 2-mercaptoethanol and the fluorescent derivatives were separated on a reversed-phase analytical column with a gradient mobile phase consisting of 50 mM acetate buffer (pH 6.5) and methanol. The retention times of the diastereoisomers of M1 (M1-“S” and M1-“R”) were 52.8 and 73.7 min, respectively; M2 diastereoisomers eluted as a single peak at 70.5 min. The fluorescence detector was set at 330 nm (excitation) and 440 nm (emission). The detection limit (at a signal-to-noise ratio of three) was about 7 μg/l. The method was applied to 25 urine samples from workers exposed to styrene. A relationship was found between urinary mandelic and phenylglyoxylic acids and mercapturic acids specific for styrene. Urine samples from ten non-exposed subjects showed no detectable amounts of analytes.  相似文献   

12.
A high-performance liquid chromatographic method with electrochemical detection (ED) has been developed for the determination of two diuretics: 4-phenoxy-3-(1-pyrrolidinyl)-5-sulfamoylbenzoic acid (piretanide) and 4-chloro-2-furfurylamino-5-sulfamoylbenzoic acid (furosemide). The chromatographic separation was performed on a μBondapak C18 column with a mobile phase of acetonitrile-water (40:60) containing 5 mM KH2PO4/K2HPO4 and with a flow-rate of 1 ml/min (69 bar). The temperature was optimized at 30 ± 0.2°C. The amperometric detector equipped with a glassy carbon electrode was operated at + 1200 mV versus Ag/AgCl in the direct current mode. The method was applied to the determination of these compounds in two concentration ranges (ppm and ppb), obtaining a reproducibility in terms of relative standard deviations lower than 1% for within-day and 4% for day-to-day and determination limits of 15 ppb for both compounds. Recoveries greater than 90% were obtained for spiked urine samples, using a liquid-liquid extraction method in the sample clean-up procedure. The LC-ED method was applied to commercially available pharmaceuticals (Seguril, furosemide 40 mg, and Perbilén, piretanide 6 mg) and urine samples obtained from healthy volunteers and hypertensive patients.  相似文献   

13.
Gliotoxin, a mycotoxin with antimicrobial and immunosuppressive capabilities, is produced by several genera of fungi including the pathogenic fungusAspergillus fumigatus. The ability of selected isolates ofA. fumigatus to produce gliotoxin on three different media was tested and a thin layer chromatographic and high performance liquid chromatographic method for quantitation of gliotoxin from rice culture was developed and is described. Rice cultures were extracted with chloroform and the resulting extract was partially purified by precipitation with petroleum ether and cleanup by gel permeation chromatography. Gliotoxin was detected by thin layer chromatography and quantitated by high performance liquid chromatography using a U.V. absorbance detector with a 254 nm filter and a mobile phase of methanol-water 4357 (V/V) with a flow rate of 2.0 ml/min. The retention time for gliotoxin was approximately 4.8 min. From rice samples spiked with gliotoxin concentrations of 0.67, 1.33, 2.67, 4.00 and 5.33g/g the average recovery was 83.8%.  相似文献   

14.
A sensitive, selective and reproducible reversed-phase high-performance liquid chromatographic method is described for the quantification of sotalol in human serum and urine. Sotalol and the internal standard, atenolol, were extracted from alkalinized serum and urine (pH 9.0) into 1-butanol—chloroform (20:60, v/v). The organic phase was evaporated, and to the residue was added 0.1 M sulphuric acid (serum analysis) or mobile phase (urie analysis). The mobile phase consisted of 0.01 M phosphate buffer (pH 3.2) and acetonitrile (20:80, v/v) containing 3 mM n-octylsodium sulphate. The flow-rate was 1.5 ml/min. The retention times of atenolol and sotalol were 7 and 10 min, respectively. Ultraviolet detection at 226 nm made it possible to achieve a detection limit of 0.03 μmol/l.  相似文献   

15.
An effective gradient high-performance liquid chromatographic method for baseline separation of urinary 2-thiothiazolidine-4-carboxylic acid (TTCA), with photodiode array detection at 271 nm was described. o-Methylhippuric acid was used as an internal standard (I.S.). A 1-ml urine sample was saturated with 300 mg of sodium sulphate, acidified with 100 μl of 6 M hydrochloric acid, extracted twice with 2 ml of diethyl ether, and after evaporation, the residue was taken up in 1 ml of 0.1% (v/v) phosphoric acid. The two mobile phases used for gradient elution were: (A) 10 mM ammonium dihydrogenphosphate (pH 3.5) and (B) same concentration of buffer but containing 20% (v/v) of methanol (pH 4.8). The flow-rate was set at 1.0 ml/min. TTCA and I.S. were detected at 2.2 and 9.1 min, respectively. The method was validated with urine samples collected from normal subjects and workers occupationally exposed to carbon disulphide. The present method enables the detection of urinary TTCA at a concentration of 0.025 mg/l. Analytical recovery and reproducibility generally exceeded 90%. The proposed method is considered more sensitive, specific and reliable than other existing methods.  相似文献   

16.
A method is described for the simultaneous determination of (+)- and (−)-homochlorcyclizine (HCZ) in human urine by high-performance liquid chromatography on a chiral stationary phase of ovomucoid-bonded silica. The pH of the buffer and organic modifier in the mobile phase markedly affected the chromatographic separation. A mobile phase of methanol—0.02 M acetate buffer (pH 4.7) (25:75, v/v) at a flow-rate of 1.0 ml/min was used for the urine assays. The ultraviolet absorption was monitored at 240 nm, and diphenhydramine was employed as the internal standard for the quantitation. (+)-HCZ, (−)-HCZ and the internal standard were eluted at retention times of 15, 25 and 8 min, respectively. The limit of determination for HCZ enantiomers was ca. 50 ng/ml of urine. One of the metabolites in human urine, which was a quaternary ammonium-linked glucuronide, could also be determined in a manner similar to unchanged HCZ after β-glucuronidase hydrolysis. A pharmacokinetic study was conducted with three healthy volunteers, who each received a single oral dose of racemic HCZ (20 mg). Distinct differences were found between the two enantiomers, particularly in the metabolic process, that is, the urinary excretion as (−)-HCZ-glucuronide within 48 h was ca. four times higher than that of the (+)-isomer. This method should be very useful for enantioselective pharmacokinetic studies of HCZ.  相似文献   

17.
A sensitive high-performance liquid chromatographic method for the determination of paromomycin in human plasma and urine was developed. Paromomycin was quantitated following pre-column derivatization with 2,4-dinitrofluorobenzene (DNFB). The chromatographic separation was carried out on a C18 column at 50°C using a mobile phase consisting of 64% methanol in water adjusted to pH 3.0 with phosphoric acid. The eluents were monitored by UV detection at 350 nm. The linearity of response for paromomycin was demonstrated at concentrations from 0.5 to 50 μg/ml in plasma and 1 to 50 μg/ml in urine. The relative standard deviation of the assay procedure is less than 5%.  相似文献   

18.
An efficient method for the determination of atenolol in human plasma and urine was developed and validated. α-Hydroxymetoprolol, a compound with a similar polarity to atenolol, was used as the internal standard in the present high-performance liquid chromatographic analysis with fluorescence detection. The assay was validated for the concentration range of 2 to 5000 ng/ml in plasma and 1 to 20 μg.ml in urine. For both plasma and urine, the lower limit of detection was 1 ng/ml. The intra-day and inter-day variabilities for plasma samples at 40 and 900 ng/ml, and urine samples at 9.5 μg/ml were <3% (n=5).  相似文献   

19.
Direct evidence has been obtained for the presence of adenosine-3:5-cyclic monophosphate (cAMP) in tobacco (Nicotiana tabacum L.) callus tissue cultures, bean (Phaseolus vulgaris L.) seedlings and immature kernels of sweet corn (Zea mays L.) through the use of a highly specific and sensitive gas chromatography-mass spectrometric assay. Levels of endogenous cAMP ranged from 70 to 126 pmol/g fresh weight. Corresponding levels of cAMP determined for the same samples using radioimmunoassay were consistently three to four times higher. Contrary to previous reports for citrus plants, measurable levels of cAMP could not be detected in young lemon leaves within the limits of detection of the mass-spectrometric assay method. In the case of tobacco callus tissue, the coumarin glucoside, scopolin, which was present in large amounts and showed similar chromatographic behaviour to cAMP, interferred strongly with the mass-spectrometric measurements of cAMP in inadequately purified extracts. The use of high-performance liquid chromatography, in addition to standard chromatographic purification methods, produced highly purified plant extracts for quantitation of cAMP and also provided a method for the separation of cAMP from its 2:3-isomer.Abbreviations cAMP adenosine-3:5-cyclic monophosphate - 2:3-cAMP adenosine-2:3-cyclic monophosphate - GC-MS-MID combined gas chromatography-mass spectrometry with selected multiple-ion-detection - HPLC high-performance liquid chromatography - RIA radioimmunoassay - TLC thin-layer chromatography  相似文献   

20.
A reversed-phase high-performance liquid chromatographic method for oxazepam in human urine samples has been developed. The sample preparation consists of an enzymatic hydrolysis with β-glucuronidase, followed by a solid-phase extraction process using Bond-Elut C2 cartridges. The mobile phase used was a methanol—water (60:40, v/v) mixture at a flow-rate of 0.50 ml/min. The column was a 3.5 cm × 4.6 mm I.D. C18 reversed-phase column. The detection system was based on a fluorescence post-column derivatization of oxazepam in mixtures of methanol and acetic acid. A linear range from 0.01 to 1 μg/ml of urine and a limit of detection of 4 ng/ml of urine were attained. Within-day recoveries and reproducibilities from urine samples spiked with 0.2 and 0.02 μg/ml oxazepam were 97.9 and 95.0 and 2.1 and 9.4%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号