首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Measurement of serum aldosterone is clinically important in the diagnosis of hypertension. While isotope dilution gas chromatography-mass spectrometry (ID-GC-MS) provides reliable results, it requires derivatization and is lengthy and time-consuming. Detection by liquid chromatography-mass spectrometry (LC-MS) is a potentially superior method. The analysis utilizes 0.5mL of serum. The samples were extracted with dichloromethane-ether. The extract was evaporated to dryness and aldosterone was analyzed by LC-MS/MS operating in the negative mode ESI after separation on a reversed-phase column. Aldosterone was also measured by RIA. The calibration curves for analysis of serum aldosterone exhibited consistent linearity and reproducibility in the range of 60-3000pmol/L. Interassay CVs were 4.3-7.5% at aldosterone concentrations of 97-993pmol/L. The lower limit of quantitation (LOQ) was 30pmol/L (signal to noise ratio=10). The mean recovery of the analyte added to serum ranged from 95 to 102%. The regression equation by LC-MS/MS (x) and RIA (y) method was: y=1.33x+185 (r=0.95; n=124). Sensitivity and specificity of the LC-MS/MS method for serum aldosterone offer advantages over GC-MS by eliminating derivatization. The novel method is rapid, reliable and simple to perform with a routine LC-MS/MS spectrometer. The sensitivity is adequate for patient samples. Aldosterone concentrations reported by nonextraction RIA were consistently higher than those produced by LC-MS/MS.  相似文献   

2.
A liquid chromatography-tandem mass spectrometric (LC-MS-MS) method with a rapid and simple sample preparation was developed and validated for the determination of Tirofiban in biological fluids. Tirofiban in serum samples was extracted and cleaned up by using an automated solid phase extraction method. An external calibration was used. The mass spectrometer was operated in the multiple reaction monitoring mode (MRM). A good linear response over the range of 2-200ng/ml was demonstrated. The accuracy for Tirofiban ranged from 94.8 to 110.8% within-day and from 103.0 to 104.7% between-day. The lower limit of quantification was 2ng/ml. This method is suitable for pharmacokinetic studies.  相似文献   

3.
In the present paper we report the LC-MS/MS determination of residues of 12 anabolic steroids in bovine serum, as an expansion of our work protocols for steroids determination in biological matrices. Steroids analyzed included α-zearalanol, β-zearalanol, α-trenbolone, β-trenbolone, methyltestosterone, α-estradiol, β-estradiol, ethynylestradiol, α-boldenone, β-boldenone, α-nortestosterone and β-nortestosterone. Following protein precipitation, serum samples were cleaned up by solid-phase extraction using Oasis HLB and Amino cartridges. Atmospheric pressure chemical ionization (APCI) in both positive and negative ionization modes was used and mass spectrometry detection was carried out in multiple reaction monitoring mode following two or (in most cases) three product ions per precursor ion. The method was validated in accordance with the Commission Decision 2002/657/EC. The decision limit (CCα) values obtained, ranged from 0.01 to 0.07 ng/ml and the detection capability (CCβ) values obtained ranged from 0.02 to 0.12 ng/ml. The recoveries ranged from 70.2% to 118.2%. The developed method is suitable for routine and confirmatory purposes such as control of illegal use in livestock production.  相似文献   

4.
A new developed gas chromatographic-high resolution mass spectrometric method for the sensitive simultaneous determination of trans-chrysanthemumdicarboxylic acid, cis- and trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane carboxylic acid, cis-3-(2,2-dibromovinyl)-2,2-dimethylcyclopropane carboxylic acid, 3-phenoxybenzoic acid and 4-fluoro-3-phenoxybenzoic acid in human urine is presented. These metabolites are biomarkers for an exposure to pyrethrum, allethrin, resmethrin, phenothrin, tetramethrin, cyfluthrin, cypermethrin, deltamethrin or permethrin. Therefore, with the help of this method for the first time a complete assessment of exposure to pyrethroid and pyrethrin insecticides is possible. After acid hydrolysis and extraction with tert-butyl-methyl-ether the residue is derivatized with 1,1,1,3,3,3-hexafluoroisopropanol and analyzed by GC/HRMS in electron impact mode (detection limits < 0.1 microg/l) as well as in negative chemical ionization mode (detection limit < 0.05 microg/l urine).  相似文献   

5.
A method for the determination of tetrabromobisphenol A (TBBPA) in human serum utilizing solid-phase extractions (SPEs) and liquid chromatography (LC) with electrospray ionization tandem MS (MS/MS) has been developed. After purification and concentration of TBBPA using consecutive SPEs on reversed-phase and normal-phase cartridges, the serum sample was subjected to LC. TBBPA was separated on a C18 reversed-phase column by gradient elution with a mixture of water, methanol, and acetonitrile as the mobile phase, and then detected with electrospray ionization MS/MS in negative ion mode. 13C12-TBBPA was suitable as an internal standard for the reproducible determination of TBBPA in human serum samples (5 g). The method has been validated in TBBPA concentration range of 5-100 pg per g serum, and the recoveries in the concentration range were higher than 83.3%. The repeatabilities of the proposed method of non-spiked control serum (6.3 pg per g serum) and spiked serum (added 5-100 pg per g serum) were within 10.0% as relative standard deviations. The limit of quantification (LOQ) for TBBPA was 4.1 pg per g serum, which was corresponded to 0.63 fmol on column.  相似文献   

6.
A rapid, sensitive and specific high-performance liquid chromatography–electrospray tandem mass spectrometric method has been developed for the determination of gestrinone (R 2323) in human serum using mifepristone (RU 486) as an internal standard. R 2323 was extracted from human serum by an ether extraction procedure. Multiple reaction monitoring was used to detect R 2323 and RU 486. The calibration curve was linear over the range of 3.5–177 ng/ml (r2≥0.99) with the limitation of detection of 0.8 ng/ml. The intra-day precision and accuracy, expressed as C.V. and RE, ranged from 2.3–13.7 to −4.8–3.0%. The inter-day precision and accuracy ranged from 5.5–14.8 to −6.7–3.1%. The mean recovery was 91.0% for R 2323, and 90.6% for the internal standard. The method was successfully applied to the pharmacokinetic study of R 2323.  相似文献   

7.
A highly sensitive and specific method of rapid resolution liquid chromatography tandem mass spectrometry (RRLC-MS/MS) in positive ionization mode has been developed and validated for pharmacokinetic study of puerarin in rat plasma. Chromatography was carried out on a Zorbax XDB C18 reversed-phase column using a mobile phase comprising a mixture of methanol and 0.05% acetic acid in water (35:65, v/v) with a flow rate of 0.3 mL/min from 0 min to 5.4 min and then 0.6 mL/min from 5.41 min to 12 min. The mass spectrometer operated in ESI positive ionization mode. Multiple reaction monitoring (MRM) was used to measure puerarin and tectoridin (internal standard). The method was sensitive with a detection limit of 0.33 ng/mL. A good linear response was observed over a range of 10-2000 ng/mL in rat plasma. The inter- and intra-day precision ranged from 2.97% to 7.52% and accuracy from 93.70% to 101.60%. This validated method was applied successfully to a pharmacokinetic study in rat plasma after intravenous administration of puerarin. The main pharmacokinetic parameters were as follows: AUC(0→t) 45.37±13.19 (mgh/L), AUC(0→∞) 47.03±14.78 (mgh/L), MRT 1.03±0.46 (h), T(1/2) 1.31±0.31 (h), V(ss) 0.09±0.02 (L), V(z) 0.17±0.04 (L), Cl 0.10±0.04 (L/h).  相似文献   

8.
A high-performance liquid chromatographic (HPLC) method with a detection limit of 5 ng/ml was developed for the analysis of trimethoprim in bovine serum. Trimethoprim and the internal standard, ormetoprim, under alkaline conditions, were first extracted into dichloromethane and then back-extracted into dilute sulphuric acid (0.15 M) and cleaned-up on a C18 cartridge. Trimethoprim was quantified on a C18 column using a triethylammonium acetate—acetonitrile—methanol (16:3:1, v/v/v) mobile phase at a flow-rate of 1.5 ml/min, with ultraviolet detection at 225 nm. This method was used to verify the accuracy of test responses obtained with the Brilliant Black Reduction test, a rapid screening method, for trimethoprim levels in the serum of steers treated with Trivetrin. Confirmation of the presence of trimethoprim in the sample extract was obtained by thermospray HPLC—mass spectrometry.  相似文献   

9.
A rapid, selective and sensitive method for the determination of the angiotensin II receptor antagonist, telmisartan, in human plasma has been developed. Telmisartan and the internal standard, diphenhydramine, were extracted from plasma using diethyl ether-dichloromethane (60:40, v/v), and separated on a Zorbax extend C(18) column using methanol-10mM ammonium acetate (85:15, v/v) adjusted to pH 4.5 after mixing with formic acid as mobile phase. Detection was carried out by multiple reaction monitoring on a Q-trap LC-MS/MS system with an ESI interface. The assay was linear over the range 0.5-600.0 ng/ml with a limit of quantitation of 0.5 ng/ml and a limit of detection of 0.05 ng/ml. Intra- and inter-day precision were <6.7% and <8.1%, respectively, and the accuracy was in the range 88.9-111.0%. The assay was applied to a pharmacokinetic study of telmisartan given as a single oral dose (80 mg) to healthy volunteers.  相似文献   

10.
A sensitive and specific high-performance liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for dioscin in rat plasma was developed. Ginsenoside Rh2 was employed as an internal standard. Dioscin is a naturally occurring saponin present in many traditional Chinese medicinal plants. Dioscin was determined after the acetonitrile-mediated plasma protein precipitation. The mobile phase consisted of acetonitrile:10 mmol/l aqueous ammonium acetate (95:5, v:v), which was pumped at 0.8 ml/min. The analytical column (100 mm x 4.6 mm i.d.) was packed with Hypersil ODS material (5 microm). The standard curve was linear from 1 to 100 ng/ml. The assay was specific, accurate (percentage deviations from nominal concentrations were <10%), precise and reproducible (within- and between-day coefficients of variation <10%). Dioscin in rat plasma was stable over three freeze-thaw cycles and at ambient temperatures for 24 h. The utility of the assay was demonstrated by determining dioscin plasma concentrations in five rats for 120 h following a single oral gavage dose of 90 mg/kg.  相似文献   

11.
Protodioscin (3-O-[alpha-L-rhamnopyranosyl-(1-->2)-{alpha-L-rhamnopyranosyl-(1-->4)}-beta-D-glucopyranosyl]-26-O-[beta-D-glucopyranosyl]-(25 R)-furost-5-ene-3 beta,26-diol) is a naturally occurring saponin present in many oriental vegetables and traditional medicinal plants, which has been associated with potent bioactivity. However, there is no specific and sensitive assay for quantitative determination of protodioscin in biological samples. We have established a rapid, sensitive and selective LC-ESI-MS/MS method to measure protodioscin in rat plasma and investigated the pharmacokinetics of protodioscin after intravenous administrations. Plasma samples were prepared after plasma protein precipitation, and a aliquot of the supernatant was injected directly onto an analytical column with a mobile phase consisted of acetonitrile-water-formic acid (80:20:0.1, v/v/v). Analytes were detected with a LC-ESI-MS/MS system in positive selected multiple reaction-monitoring mode. The lower limit of quantification (LLOQ) was 20.0 ng/mL and a linear range of 20-125,000 ng/mL. The intra- and inter-day relative standard deviation (R.S.D.) across three validation runs over the entire concentration range was <8.0%. Accuracy determined at three concentrations (50, 5000 and 50,000 ng/mL for protodioscin) ranged from 0.2 to 1.8% as terms of relative error (R.E.). Each plasma sample was chromatographed within 3.5 min. This LC-ESI-MS/MS method allows accurate, high-throughput analysis of protodioscin in small amounts of plasma.  相似文献   

12.
A sensitive method was developed for quantitation of the cytotoxic antibiotic l-alanosine in human plasma. Alanosine was extracted from plasma by anion-exchange solid phase extraction, derivatized with dansyl chloride and analyzed by liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization in negative mode. Dansylation led to 50-fold improvement of method sensitivity over non-dansylated alanosine with a resulting 20 ng/ml limit of alanosine quantitation in plasma being achieved. The method was validated and applied for clinical studies of alanosine administered to cancer patients.  相似文献   

13.
A liquid chromatography-electrospray tandem mass spectrometry method was developed and validated to quantitate solifenacin in human plasma. The assay was based on protein precipitation with methanol and liquid chromatography performed on a pentafluorophenylpropylsilica column (50×4mm, 3μm particles), the mobile phase consisted of methanol - 100mM ammonium acetate containing 1% of formic acid (90:10, v/v). Quantification was through positive-ion mode and selected reaction monitoring at m/z 363→193 and 368→198 for solifenacin and the internal standard solifenacin-D(5), respectively. The lower limit of quantitation was 0.47ng/ml using 0.25ml of plasma and linearity was demonstrated up to 42ng/ml. Intra-assay and inter-assay precision expressed by relative standard deviation was less than 11% and inaccuracy did not exceed 11% at all levels. The assay was applied to the analysis of samples from a pharmacokinetic study.  相似文献   

14.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.  相似文献   

15.
A liquid chromatographic-tandem mass spectrometric (LC-MS-MS) assay was developed and validated to quantitatively determine olanzapine (OLZ) concentrations in human blood. Liquid-liquid extraction, using n-butanol:cyclohexane (3:47, v/v), was used to isolate OLZ and its internal standard, LY170158, from the biological matrix. Chromatographic resolution of OLZ from endogenous interferences and known metabolites was accomplished with a MetaChem Monochrom HPLC column (4.6 x 150 mm, d(p) 5 microm). Detection occurred using a Perkin-Elmer Sciex API III Plus triple quadrupole mass spectrometer using positive ion APCI and multiple reaction monitoring (MRM). The linear dynamic range was from 5 to 500 ng ml(-1) based on a 0.25-ml aliquot of human blood. The inter-day precision (%RSD) and accuracy (%RE) ranged from 3.65 to 10.64 and from -2.14 to 3.07, respectively. Modifications to an existing assay for the determination of OLZ in human plasma were necessary. A different structural analog was used as the internal standard due to instability observed for the original analog when using human blood as the matrix. A second modification was the addition of the anti-oxidant sodium ascorbate to inhibit degradation of OLZ in human blood, as has been noted by other investigators. Upon fortification of human blood with sodium ascorbate (final concentration, 0.33 mM), OLZ was found to be stable for at least 1 week at -70 degrees C as well as through two freeze-thaw cycles. This assay, which will be used to investigate the distribution of OLZ in human blood, grants insight into the proper sample handling conditions needed to perform valid determinations of OLZ in human blood.  相似文献   

16.
Despite the new advances in bioanalytical techniques, the analysis of low-molecular-weight organic acids in complex matrices is still a challenge. Although new strategies applying liquid chromatography-tandem mass spectrometry (LC-MS/MS) seem to be promising, sample preparation methodologies hamper its application in most clinical laboratories. The quantitation of methylmalonic acid (MMA) in biological matrices is an emblematic example due to its low concentration, the need for derivatization to increase its molecular weight, and the presence of the physiologically more abundant isomer succinic acid. Here we present a new strategy for rapid and sensitive MMA quantitation by combining alkylative extraction and LC-MS/MS. Alkylative extraction conditions were optimized to allow endogenous detection of MMA using only 50 μL of serum with a short sample preparation procedure. The formation of a unique ion from the MMA dipentafluorobenzyl derivative in negative atmospheric pressure chemical ionization (APCI) allowed its detection with high sensitivity and with no interference from succinic acid, a more abundant physiologically present isomer.  相似文献   

17.
Liquid chromatographic/tandem mass spectrometric methods using pneumatically assisted electrospray ionisation (LC-ESI-MS/MS) was developed for determination of 18 mycotoxins and metabolites-ochratoxin A, zearalenone, alpha-zearalenol, beta-zearalenol, alpha-zearalanol (zeranol), beta-zearalanol (taleranol), fumonisin B1, fumonisin B2, T-2 toxin, HT-2 toxin, T-2 triol, diacetoxyscirpenol (DAS), 15-monoacetoxyscirpenol (MAS), deoxynivalenol (DON), 3-acetyldeoxynivalenol (3-AcDON), 15-acetyldeoxynivalenol (15-AcDON), deepoxy-deoxynivalenol (DOM-1) and aflatoxin M1--in milk. The mycotoxins were extracted and cleaned up simultaneously. Extraction and removal of lipophilic compounds was performed at pH 2 using a two-phase mixture of acetonitrile and hexane. The acetonitrile concentration of the aqueous phase was reduced and the pH was adjusted to 8.5 before clean up by solid phase extraction (SPE) on Oasis HLB. The toxins DON, DOM-1, 3-AcDON, 15-AcDON, ochratoxin A, zearalenone, alpha-zearalenol, beta-zearalenol, alpha-zearalanol and beta-zearalanol were detected in negative ion mode after separation on a Hypersil ENV analytical column, while the toxins T-2 toxin, HT-2 toxin, T-2 triol, DAS, MAS, fumonisin B1, fumonisin B2 and aflatoxin M1 were detected in positive ion mode after separation on a Luna C18 column. Two transition products were monitored for each compound. The extraction and SPE conditions were optimised to obtain maximum recovery and minimum signal suppression/enhancement. The detection capabilities related to the transition products of lowest abundance were in the range 0.020-0.15 microg/l. The mean true recoveries were in the range 76-108% at levels of 0.2-10 microg/l.  相似文献   

18.
A rapid, simple and sensitive method was developed for the determination of para-aminohippuric acid (PAH) in rat plasma using liquid chromatography tandem mass spectrometry (LC-MS-MS). Acetaminophen was used as the internal standard. Chromatographic separation was performed using a Symmetry C18 column and the mobile phase was composed of A: 2 mM ammonium formate and 0.1% formic acid in water and B: 2 mM ammonium formate and 0.1% formic acid in acetonitrile (ACN) (A:B, 30:70, v/v). Detection was performed on a triple–quadrupole tandem mass spectrometer using positive ion mode electrospray ionization (ESI) in the multiple reaction monitoring (MRM) mode. The MS/MS ion transitions monitored were m/z 195.2 → 120.2 and 152.1 → 110.1 for PAH and acetaminophen, respectively. Good linearity is observed over the concentration range of 0.1–500 μg/ml. The method was proved to be accurate and reliable and was applied to a pharmacokinetic study in rat.  相似文献   

19.
A simple, rapid and specific high-performance liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS) has been developed and validated for the determination of ketoconazole in human plasma. The method used diethyl ether to extract the ketoconazole and the internal standard (I.S.) R51012 from alkalinized plasma sample. The LC separation was on a C(18) column (50 x 3 mm, 5 microm) using acetonitrile-water-formic acid (75:25:1, v/v/v) mobile phase. The retention times were approximately 1.8 min for both ketoconazole and the I.S. The MS-MS detection was by monitoring 531.2-->82.1 (m/z) for ketoconazole, and 733.5-->460.2 (m/z) for the I.S. The dynamic range was from 20.0 to 10000 ng/ml based on 0.1 ml plasma, with linear correlation coefficient of > or =0.9985. The run time was 2.5 min/injection. The recoveries of ketoconazole and the I.S. were 102 and 106%, respectively. The precision and accuracy of the control samples were with the relative standard deviations (RSDs) of < or =4.4% (n=6) and the relative errors (REs) from -0.6 to 1.4% for intra-day assay, and < or =8.6% RSD (n=18) and -1.4 to 0.9% RE for inter-day assay. The partial volume tests demonstrated good dilution integrity. Three freeze-thaw cycles, keeping plasma samples at ambient for 24 h, storing extracted samples at ambient for 24 h, and storing frozen plasma samples at approximately -20 degrees C for up to 2 months did not show substantial effects.  相似文献   

20.
Diesters of 1,2-benzenedicarboxylic acid are a family of industrial compounds called "phthalates." The physical and chemical properties of these diesters, and therefore their potential uses, depend on the structure of the dialkyl or alkyl/aryl side chain. The urinary concentrations of phthalate monoesters, which are metabolites, have been used as biomarkers of human exposure to specific phthalates. However, several phthalates, particularly those with side chains of eight or more carbon atoms, are complex mixtures of isomers. For these, the phthalate metabolites to be used as biomarkers of exposure have not been unequivocally identified. We developed a method for assessing total exposure to phthalates, including the isomeric mixtures of high molecular weight phthalates, by measuring the concentration of phthalic acid (PA) in human urine after acid hydrolysis of the phthalate metabolites to PA. The present method accurately assesses total exposure to phthalates without noticeable contamination from the ubiquitous phthalates in the environment, but it gives no information about the parent phthalate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号