IntroductionThe stereotactic irradiation is a new approach for low-risk prostate cancer. The aim of the present study was to evaluate a schema of stereotactic irradiation of the prostate with an integrated-boost into the tumor.Material and methodsThe prostate and the tumor were delineated by a radiologist on CT/MRI fusion. A 9-coplanar fields IMRT plan was optimized with three different dose levels: 1) 5 × 6.5 Gy to the PTV1 (plan 1), 2) 5 × 8 Gy to the PTV1 (plan 2) and 3) 5 × 6.5 Gy on the PTV1 with 5 × 8 Gy on the PTV2 (plan 3). The maximum dose (MaxD), mean dose (MD) and doses received by 2% (D2), 5% (D5), 10% (D10) and 25% (D25) of the rectum and bladder walls were used to compare the 3 IMRT plans.ResultsA dose escalation to entire prostate from 6.5 Gy to 8 Gy increased the rectum MD, MaxD, D2, D5, D10 and D25 by 3.75 Gy, 8.42 Gy, 7.88 Gy, 7.36 Gy, 6.67 Gy and 5.54 Gy. Similar results were observed for the bladder with 1.72 Gy, 8.28 Gy, 7.01 Gy, 5.69 Gy, 4.36 Gy and 2.42 Gy for the same dosimetric parameters. An integrated SBRT boost only to PTV2 reduced by about 50% the dose difference for rectum and bladder compared to a homogenous prostate dose escalation. Thereby, the MD, D2, D5, D10 and D25 for rectum were increased by 1.51 Gy, 4.24 Gy, 3.08 Gy, 2.84 Gy and 2.37 Gy in plan 3 compared to plan 1.ConclusionsThe present planning study of an integrated SBRT boost limits the doses received by the rectum and bladder if compared to a whole prostate dose escalation for SBRT approach.  相似文献   

2.
AimTo assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction.BackgroundImplementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution.Materials and methodsSeventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed.ResultsIn 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively.ConclusionSufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.  相似文献   

3.
4.
PurposeVentricular tachycardia (VT) is a life-threatening heart disorder. The aim of this preliminary study is to assess the feasibility of stereotactic body radiation therapy (SBRT) photon and proton therapy (PT) plans for the treatment of VT, adopting robust optimization technique for both irradiation techniques.MethodsECG gated CT images (in breath hold) were acquired for one patient. Conventional planning target volume (PTV) and robust optimized plans (25GyE in single fraction) were simulated for both photon (IMRT, 5 and 9 beams) and proton (SFO, 2 beams) plans. Robust optimized plans were obtained both for protons and photons considering in the optimization setup errors (5 mm in the three orthogonal directions), range (±3.5%) and the clinical target volume (CTV) motion due to heartbeat and breath-hold variability.ResultsThe photon robust optimization method, compared to PTV-based plans, showed a reduction in the average dose to the heart by about 25%; robust optimization allowed also reducing the mean dose to the left lung from 3.4. to 2.8 Gy for 9-beams configuration and from 4.1 to 2.9 Gy for 5-beams configuration. Robust optimization with protons, allowed further reducing the OAR doses: average dose to the heart and to the left lung decreased from 7.3 Gy to 5.2 GyE and from 2.9 Gy to 2.2 GyE, respectively.ConclusionsOur study demonstrates the importance of the optimization technique adopted in the treatment planning system for VT treatment. It has been shown that robust optimization can significantly reduce the dose to healthy cardiac tissues and that PT further increases this gain.  相似文献   

5.
The aim of this study was to evaluate the dosimetric effect of continuous motion monitoring based localization (Calypso, Varian Medical Systems), gating and intrafraction motion correction in prostate SBRT. Delivered doses were modelled by reconstructing motion inclusive dose distributions for different localization strategies. Actually delivered dose (strategy A) utilized initial Calypso localization, CBCT and additional pre-treatment motion correction by kV-imaging and Calypso, and gating during the irradiation. The effect of gating was investigated by simulating non-gated treatments (strategy B). Additionally, non-gated and single image-guided (CBCT) localization was simulated (strategy C). A total of 308 fractions from 22 patients were reconstructed. The dosimetric effect was evaluated by comparing motion inclusive target and risk organ dose-volume parameters to planned values. Motion induced dose deficits were seen mainly in PTV and CTV to PTV margin regions, whereas CTV dose deficits were small in all strategies: mean ± SD difference in CTVD99% was –0.3 ± 0.4%, −0.4 ± 0.6% and –0.7 ± 1.2% in strategies A, B and C, respectively. Largest dose deficits were seen in individual fractions for strategy C (maximum dose reductions were −29.0% and –7.1% for PTVD95% and CTVD99%, respectively). The benefit of gating was minor, if additional motion correction was applied immediately prior to irradiation. Continuous motion monitoring based localization and motion correction ensured the target coverage and minimized the OAR exposure for every fraction and is recommended to use in prostate SBRT. The study is part of clinical trial NCT02319239.  相似文献   

6.
AimTo present the segmented photon beams technique (SPBT) for irradiation of postmastectomy patients.BackgroundIn majority of techniques for irradiation of posmastectomy patients, a few adjacent photon or electron beams were usually implemented in order to encompass different parts of the target. In the presented SPBT technique, the radiotherapy plan consists of 6 isocentric photon beams and the area CTV includes both the chest wall and the supraclavicular area. This makes it possible to provide a uniform dose to the CTV with no hot and cold points and enables the determination of doses for the entire volume of critical organs.Methods and materialThe treatment forward-IMRT plan comprises six isocentric 4 and 15 MV photon beams. Modulation of the dose distribution for each field was obtained by applying three segments on average. The total dose of 45 Gy was administered in 20 fractions. Dose distributions in target volume and organs at risk were evaluated for 70 randomly chosen patients.ResultsOn average, 94.8% of the CTV volume received doses within 95–107% of the prescribed dose. The average volume of the heart receiving a dose of 30 Gy and lager was 2% for patients with left breast cancer. The average dose to the lung on the irradiation side was always lower than 15.5 Gy and the average V20 Gy was below 35.5%.ConclusionsThe SPBT complies with requirements for high dose homogeneity within the target volume and satisfactory level of sparing of organs at risk.  相似文献   

7.
A method for quantitative visualization of the uncertainty in the predicted tumor control probability (TCP) and normal tissue complication probability (NTCP) in radiotherapy has been developed. Uncertainties of TCP and NTCP due to inter-individual variation of the underlying radiosensitivity parameters was simulated by sampling the prescribed dose from a uniform distribution and the radiosensitivity-parameters from a Gaussian distribution. The result is visualized as a scatter-plot superimposed to the population-based dose response curves using the prescribed dose as the common dosimetric variable. In addition, probability histograms are derived quantifying the probability of specific TCP- or NTCP-values for individual patients from the underlying population. The method is exemplified with a pleural mesothelioma case with the lung as organ at risk. A prescribed dose of 54 Gy together with radiosensitivity variations of 6% (tumor) and 10% (normal tissue) results in a TCP of 85% (range 68–94%, 90% confidence interval, CI) and an NTCP of 4% (range 3–6%, 90% CI), respectively. Increasing the radiosensitivity variation of the tumor to 15% and reducing the lung tolerance dose by 25% results in values of 84% (range 51–97%, 90% CI) for TCP and 9% (range 6–12%, 90% CI) for NTCP. Increasing the dose to 60 Gy leads to TCP- and NTCP-values of 93% (range 69–100%, 90% CI) and 12% (range 8–17%, 90% CI), respectively. The new method visualizes the uncertainty of TCP- and NTCP-values and hence of the therapeutic window. This can help the clinician to assess the treatment plan for the individual patient.  相似文献   

8.
BackgroundThe most common site of recurrence of prostate cancer after definite radiation therapy is the dominant intraprostatic lesion (DIL). This study aimed to investigate the feasibility and safety of definite volumetric modulated arc therapy (VMAT) with simultaneous integrated boost (SIB) to the DIL in patients with unfavorable intermediate to high-risk prostate cancer.Materials and methodsIn this prospective uncontrolled clinical trial, patients were delivered VMAT at a dose of 87.75 Gy in 39 fractions or 70 Gy in 20 fractions to the DIL in combination with androgen deprivation therapy. Genitourinary (GU) and rectal toxicity, International Prostate Symptom Score (IPSS) and IPSS quality of life (IPSS-QOL) score were collected.ResultsForty-five patients with a median follow-up of 20 months were analyzed. The cumulative incidence of acute grade ≥ 2 GU and rectal toxicity was 33.1% and 9.5%, respectively. Regarding late toxicity, the cumulative incidence of grade ≥ 2 GU and rectal toxicity was 12.6% and 2.8%, respectively. During treatment, the mean increase of IPSS was +7.4 ± 4.2 and the mean increase of IPSS-QOL was +1.7 ± 1.3. However, both IPSS and IPSS-QOL scores returned to their baseline levels by 3-months post-treatment. No significant correlation between baseline characteristics and grade ≥ 2 GU or rectal toxicity was found.ConclusionFocal SIB to the DIL of ≥ 90 Gy EQD2 in unfavorable intermediate to high-risk prostate cancer patients resulted in tolerable toxicity profiles. The mean IPSS and IPSS-QOL scores both worsened during treatment; however, both scores returned to baseline level by 3 months after treatment.  相似文献   

9.
PurposeRadiation treatment planning inherently involves multiple conflicting planning goals, which makes it a suitable application for multicriteria optimization (MCO). This study investigates a MCO algorithm for VMAT planning (VMAT–MCO) for prostate cancer treatments including pelvic lymph nodes and uses standard inverse VMAT optimization (sVMAT) and Tomotherapy planning as benchmarks.MethodsFor each of ten prostate cancer patients, a two stage plan was generated, consisting of a stage 1 plan delivering 22 Gy to the prostate, and a stage 2 plan delivering 50.4 Gy to the lymph nodes and 56 Gy to the prostate with a simultaneous integrated boost. The single plans were generated by three planning techniques (VMAT–MCO, sVMAT, Tomotherapy) and subsequently compared with respect to plan quality and planning time efficiency.ResultsPlan quality was similar for all techniques, but sVMAT showed slightly better rectum (on average Dmean −7%) and bowel sparing (Dmean −17%) compared to VMAT–MCO in the whole pelvic treatments. Tomotherapy plans exhibited higher bladder dose (Dmean +42%) in stage 1 and lower rectum dose (Dmean −6%) in stage 2 than VMAT–MCO. Compared to manual planning, the planning time with MCO was reduced up to 12 and 38 min for stage 1 and 2 plans, respectively.ConclusionMCO can generate highly conformal prostate VMAT plans with minimal workload in the settings of prostate-only treatments and prostate plus lymph nodes irradiation. In the whole pelvic plan manual VMAT optimization led to slightly improved OAR sparing over VMAT–MCO, whereas for the primary prostate treatment plan quality was equal.  相似文献   

10.
ObjectiveTo assess the feasibility of treatment planning for pancreatic tumours subject to respiratory motion using field-specific target volumes (FTV) and field-specific organs at risk (FOAR) using four-dimensional computed tomography (4DCT).MethodsFourteen pancreatic cancer patients underwent 4DCT. Radiation oncologists contoured the gross tumour volume (GTV), clinical target volume (CTV), spinal cord, duodenum, kidneys, and stomach. The gating duty cycle was set to 30 % around exhalation. FTV and FOAR were calculated using the 4DCT dataset. Planning target volumes (PTV) and planning organs at risk volumes (PRV) were defined as equal to FTV and FOAR, respectively. A dose of 55.2 Gy relative biological effectiveness (RBE) was planned to target the PTV from four beam angles. A single field uniform dose (SFUD) plan was selected. The dose distribution, including intrafractional motion changes, was generated.ResultsThe mean volume of target receiving 95 % of the planned doses was 96.4 ± 4.1 % to the GTV and 94.7 ± 0.9 % to the CTV. The highest dose to 2 cc of duodenal volume was 27.5 Gy (RBE). The volume of the stomach receiving ⩾30 Gy (RBE) was <7.0 cc in all patients. All metrics for OARs satisfied dose constraints.ConclusionDose to the CTV was covered sufficiently by the 4DCT-generated FTV, and dose to OARs was reduced by 4DCT-generated FOAR. This methodology may prevent adverse reactions while preserving local tumour control.  相似文献   

11.
PurposeStereotactic body image guided radiation therapy (SBRT) shows good results for lung cancer treatment. Better normal tissue sparing might be achieved with scanned carbon ion therapy (PT). Therefore an in silico trial was conducted to find potential advantages of and patients suited for PT.MethodsFor 19 patients treated with SBRT, PT plans were calculated on 4D-CTs with simulated breathing motion. Prescribed single fraction dose was 24 Gy and OAR constraints used for photon planning were respected. Motion was mitigated by rescanning and range-adapted ITVs. Doses were compared to the original SBRT plans.ResultsCTV coverage was the same in SBRT and PT. The field-specific PTV including range margins for PT was 1.5 (median, 25–75% 1.3–2.1) times larger than for SBRT. Nevertheless, maximum point dose and mean dose in OARs were higher in SBRT by 2.8 (1.6–3.7) Gy and 0.7 (0.3–1.6) Gy, respectively. Patients with a CTV >2.5 cc or with multiple lung lesions showed larger differences in OAR doses in favor of PT.ConclusionsPatients receive less dose in critical OARs such as heart, spinal cord, esophagus, trachea and aorta with PT, while maintaining the same target coverage. Patients with multiple or larger lesions are particularly suited for PT.  相似文献   

12.
Low dose rate prostate brachytherapy treatments began at the Royal Adelaide Hospital (RAH), Australia, in September 2004. This paper will focus on the evolution of treatment technique since then showing how procedural improvements have enabled timely diagnosis of under-dose and scheduling of top-up treatments for sub-optimum implants, and how significant time savings have been achieved for staff and patients. In addition, implant dosimetry trends over this period have been investigated and results are presented. Iodine-125 seeds (Oncura model 6711) have been used since LDR prostate treatments began, with an aim to deliver a prostate dose of 145 Gy. Three key changes in implant technique took place during the period Sept 2004 to Sept 2011. The live implant dosimetry trends of the prostate D90, urethra V150, and rectum D0.1cc and D2.0cc, were assessed to see if the change in technique had an impact on the treatment planning and seed deployment. The switch from manual loading of seeds to pre-loaded needles and the change from a two-step pre-planning procedure to live planning have realized the greatest time savings with approximately 1.0 FTE physicist day saved per 2 patient implant day and 2 patient visits saved per treatment. Dosimetric parameters also improved with mean implant D90s rising from 166 Gy to 180 Gy. The average Urethra D10 also increased over the study group, rising from 186 Gy to 199 Gy while the rectum dose remained unchanged. Both rectum and urethra dose remained below GEC-ESTRO guidelines despite the observed rise in urethral dose.  相似文献   

13.
IntroductionTo investigate the dosimetric impact of daily on-line repositioning during a full course of IMRT for prostate cancer.Materials and methodsTwenty patients were treated with image-guided IMRT. Each pre-treatment plan (Plan A) was compared with a post-treatment plan sum (Plan B) based on couch shifts measured. The delivered dose to the prostate without a daily repositioning was inferred by considering each daily couch shift during the whole course of image-guided IMRT (i.e. plan B). Dose metrics were compared for prostate CTV (P-CTV) and PTV (P-PTV) and for organs at risk. Ten patients were treated with a 5 mm margin and 10 patients with a 10 mm margin.ResultsFor plan A vs plan B: the average D95, D98, D50, D mean and EUD were: 76.4 Gy vs 73.9 Gy (p = 0.0007), 75.4 Gy vs 72.3 Gy (p = 0.001), 78.9 Gy vs 78.4 Gy (p = 0.014), 78.7 Gy vs 77.8 Gy (p = 0.003) and 78.1 Gy vs 75.9 Gy (p = 0.002), respectively for P-CTV, and 73.2 Gy vs 69.3 Gy (p = 0.0006), 70.7 Gy vs 66.0 Gy (p = 0.0008), 78.3 Gy vs 77.5 Gy (p = 0.001), 77.8 Gy vs 76.4 Gy (p = 0.0002) and 74.4 Gy vs 69.2 Gy (p = 0.003), respectively for P-PTV. Margin comparison showed no differences in dose metrics between the two plans except for D98 of the rectum in plan B which was significantly higher with a 10 mm margin.ConclusionsThe absence of daily image-guided IMRT resulted in a significantly less uniform and less homogeneous dose distribution to the prostate. A reduction in PTV margin showed neither a lower target coverage nor a better spare of OAR with and without daily image-guided IMRT.  相似文献   

14.
PurposeThis study aims to investigate the feasibility of using convolutional neural networks to predict an accurate and high resolution dose distribution from an approximated and low resolution input dose.MethodsSixty-six patients were treated for prostate cancer with VMAT. We created the treatment plans using the Acuros XB algorithm with 2 mm grid size, followed by the dose calculated using the anisotropic analytical algorithm with 5 mm grid with the same plan parameters. U-net model was used to predict 2 mm grid dose from 5 mm grid dose. We investigated the two models differing for the training data used as input, one used just the low resolution dose (D model) and the other combined the low resolution dose with CT data (DC model). Dice similarity coefficient (DSC) was calculated to ascertain how well the shape of the dose-volume is matched. We conducted gamma analysis for the following: DVH from the two models and the reference DVH for all prostate structures.ResultsThe DSC values in the DC model were significantly higher than those in the D model (p < 0.01). For the CTV, PTV, and bladder, the gamma passing rates in the DC model were significantly higher than those in the D model (p < 0.002–0.02). The mean doses in the CTV and PTV for the DC model were significantly better matched to those in the reference dose (p < 0.0001).ConclusionsThe proposed U-net model with dose and CT image used as input predicted more accurate dose.  相似文献   

15.
PurposeTo implement a daily CBCT based dose accumulation technique in order to assess ideal robust optimization (RO) parameters for IMPT treatment of prostate cancer.MethodsTen prostate cancer patients previously treated with VMAT and having daily CBCT were included. First, RO-IMPT plans were created with ± 3 mm and ± 5 mm patient setup and ± 3% proton range uncertainties, respectively. Second, the planning CT (pCT) was deformably registered to the CBCT to create a synthetic CT (sCT). Both daily and weekly sampling strategies were employed to determine optimal dose accumulation frequency. Doses were recalculated on sCTs for both ± 3 mm/±3% and ± 5 mm/±3% uncertainties and were accumulated back to the pCT. Accumulated doses generated from ± 3 mm/±3% and ± 5 mm/±3% RO-IMPT plans were evaluated using the clinical dose volume constraints for CTV, bladder, and rectum.ResultsDaily accumulated dose based on both ± 3mm/±3% and ±5 mm/±3% uncertainties for RO-IMPT plans resulted in satisfactory CTV coverage (RO-IMPT3mm/3% CTVV95 = 99.01 ± 0.87% vs. RO-IMPT5mm/3% CTVV95 = 99.81 ± 0.2%, P = 0.002). However, the accumulated dose based on ± 3 mm/3% RO-IMPT plans consistently provided greater OAR sparing than ±5 mm/±3% RO-IMPT plans (RO-IMPT3mm/3% rectumV65Gy = 2.93 ± 2.39% vs. RO-IMPT5mm/3% rectumV65Gy = 4.38 ± 3%, P < 0.01; RO-IMPT3mm/3% bladderV65Gy = 5.2 ± 7.12% vs. RO-IMPT5mm/3% bladderV65Gy = 7.12 ± 9.59%, P < 0.01). The gamma analysis showed high dosimetric agreement between weekly and daily accumulated dose distributions.ConclusionsThis study demonstrated that for RO-IMPT optimization, ±3mm/±3% uncertainty is sufficient to create plans that meet desired CTV coverage while achieving superior sparing to OARs when compared with ± 5 mm/±3% uncertainty. Furthermore, weekly dose accumulation can accurately estimate the overall dose delivered to prostate cancer patients.  相似文献   

16.
PurposeImage guided adaptive radiotherapy (IGART) strategies can be used to include the temporal aspects of radiotherapy treatment. A dosimetric evaluation of on- and off-line adaptive strategies are done in this study.MethodsA library of equivalent uniform dose (EUD)-based Intensity Modulated Radiotherapy Treatment plans with incrementally increasing clinical target volume (CTV)-to-planning target volume (PTV) margins were developed for 10 patients. Utilizing daily computed tomography (CT) images an on-line strategy using a margin-of-the-day (MOD) concept that selects the best plan from the library was employed. This was compared to an off-line strategy with full analysis of accumulated dose between fractions where dosimetric deviations from the treatment intent triggered plan adaptation. A fixed margin treatment approach was used as benchmark.ResultsUsing fixed margins of <15 mm lead to under-dosages of more than 5 Gy in total delivered dose. The average CTV EUD for the off-line and on-line strategy was 50.0 ± 5.0 Gy and 50.4 ± 2.0 Gy respectively and OAR doses were comparable.ConclusionA fixed margin treatment approach yields a significant probability of CTV under-dosage. Using EUD dose metrics CTV coverage can be restored in both the off-line and on-line adaptive strategies at acceptable OAR dose levels. Considering the workload and time on the treatment machine, the off-line strategy proves to be sufficient and more practical.  相似文献   

17.
PurposeTo compare target volume coverage and critical organ dosimetry of intraoperative treatment plans for loose seed (LS) and stranded seed (SS) 125I permanent implants for low and intermediate risk prostate cancer.MethodsTwo hundred and five patients who underwent permanent seed brachytherapy were included in the study. For prostate dosimetry V90, V100, V150, V200, D90 and COIN were used. The dose to urethra and rectum was determined by the maximal dose and relative doses that cover specified volumes. Means and standard deviations were calculated and statistically compared.ResultsOn average, 54 (range, 30–78) and 48 (range, 31–67) seeds were implanted in the prostate with individual median activities of 0.62 U (range, 0.520.70 U) and 0.71 U (range, 0.65–0.71 U) for LS and SS technique, respectively. The target coverage was slightly better with SS (V100: 98% vs. 96%, p < 0.05; D90: 172 Gy vs. 166 Gy, p < 0.05), but more conformal dose distributions were observed with LS (COIN: 0.70 vs. 0.63, p < 0.05). The dose homogeneity did not differ significantly between the two groups. Regarding the dose to urethra and rectum all dose parameters were significantly lower with LS.ConclusionsLS resulted in less dose to the urethra and rectum compared to SS in intraoperative dosimetry. A slightly better target volume coverage with decreased conformity of dose distribution is reported with SS. More studies are necessary to determine how these results will affect postoperative dosimetry, and ultimately, clinical outcome.  相似文献   

18.
The impact of a rectal spacer and an increased near maximum target dose in VMAT prostate SBRT is studied.For a group of 11 patients (35 Gy-in-five-fractions VMAT prostate SBRT) a set of 4 plans were generated, namely two VMAT plans, with D2%  37.5 Gy (Hom) and with D2%  40.2 Gy (Het), were created for each of two CT scans taken before (NoSpc) and after (Spc) transperineal spacer insertion. Consequently the methodology for parameter invariant TCP (tumor control probability) plan ranking was applied for comparison of the plans in terms of tumor control. NTCPs (normal tissue complication probabilities) were calculated for rectum and bladder using Lyman’s model.For all 11 patients the TCP plan ranking has shown that the Het plans would perform considerably better in TCP terms than the Hom ones. The plans without rectal spacer were ranked worse compared to those with rectal spacer except for one set of Hom plans. The calculated NTCPs for rectum produced by the Het plans were quite similar to the NTCPs of the Hom ones. The rectal NTCPs of the Hom Spc plans were always lower than the NTCPs of the Hom NoSpc plans. The NTCP values for bladder were extremely low in all cases.The use of rectal spacer leads in general to lower risk of rectal complications, as expected, and even to better tumor control. Plans with increased near maximum target dose (D2%  40.2 Gy) are expected to perform much better in terms of tumor control than those with D2%  37.5 Gy.  相似文献   

19.
AimTo evaluate the treatment plans of 3D image-guided brachytherapy (BT) and stereotactic robotic radiotherapy with online image guidance – CyberKnife (CK) in patients with locally advanced cervix cancer.Methods and materialsTen pairs of plans for patients with locally advanced inoperable cervical cancer were created using MR based 3D brachytherapy and stereotaxis CK. The dose that covers 98% of the target volume (HR CTV D98) was taken as a reference and other parameters were compared.ResultsOf the ten studied cases, the dose from D100 GTV was comparable for both devices, on average, the BT GTV D90 was 10–20% higher than for CK. The HR CTV D90 was higher for CK with an average difference of 10–20%, but only fifteen percent of HR CTV (the peripheral part) received a higher dose from CK, while 85% of the target volume received higher doses from BT. We found a significant organ-sparing effect of CK compared to brachytherapy (20–30% lower doses in 0.1 cm3, 1 cm3, and 2 cm3).ConclusionBT remains to be the best method for dose escalation. Due to the significant organ-sparing effect of CK, patients that are not candidates for BT could benefit from stereotaxis more than from classical external beam radiotherapy.  相似文献   

20.
This study investigates the impact of breathing motion on proton breast treatment plans. Twelve patients with CT datasets acquired during breath-hold-at-inhalation (BHI), breath-hold-at-exhalation (BHE) and in free-breathing (FB) were included in the study. Proton plans were designed for the left breast for BHI and subsequently recalculated for BHE or designed for FB and recalculated for the extreme breath-hold phases. The plans were compared from the point of view of their target coverage and doses to organs-at-risk. The median amplitude of breathing motion determined from the positions of the sternum was 4.7 mm (range 0.5–14.6 mm). Breathing motion led to a degradation of the dose coverage of the target (heterogeneity index increased from 4–7% to 8–11%), but the degraded values of the dosimetric parameters of interest fulfilled the clinical criteria for plan acceptance. Exhalation decreased the lung burden [average dose 3.1–4.5 Gy (RBE)], while inhalation increased it [average dose 5.8–6.8 Gy (RBE)]. The individual values depended on the field arrangement. Smaller differences were seen for the heart [average dose 0.1–0.2 Gy (RBE)] and the LAD [1.9–4.6 Gy (RBE)]. Weak correlations were generally found between changes in dosimetric parameters and respiratory motion. The differences between dosimetric parameters for various breathing phases were small and their expected clinical impact is consequently quite small. The results indicated that the dosimetric parameters of the plans corresponding to the extreme breathing phases are little affected by breathing motion, thus suggesting that this motion might have little impact for the chosen beam orientations with scanned proton beams.  相似文献   