首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Breast cancer is a globally widespread disease whose detection has already been significantly improved by the introduction of screening programs. Nevertheless, mammography suffers from low soft tissue contrast and the superposition of diagnostically relevant anatomical structures as well as from low values for sensitivity and specificity especially for dense breast tissue. In recent years, two techniques for X-ray breast imaging have been developed that bring advances for the early detection of breast cancer. Grating-based phase-contrast mammography is a new imaging technique that is able to provide three image modalities simultaneously (absorption-contrast, phase-contrast and dark-field signal). Thus, an enhanced detection and delineation of cancerous structures in the phase-contrast image and an improved visualization and characterization of microcalcifications in the dark-field image is possible. Furthermore, latest studies about this approach show that dose-compatible imaging with polychromatic X-ray sources is feasible. In order to additionally overcome the limitations of projection-based imaging, efforts were also made towards the development of breast computed tomography (BCT), which recently led to the first clinical installation of an absorption-based BCT system. Further research combining the benefits of both imaging technologies is currently in progress. This review article summarizes the latest advances in phase-contrast imaging for the female breast (projection-based and three-dimensional view) with special focus on possible clinical implementations in the future.  相似文献   

2.
X-ray phase-contrast computed tomography is an emerging imaging technology with powerful capabilities for three-dimensional (3D) visualization of weakly absorbing objects such as biological soft tissues. This technique is an extension of existing X-ray applications because conventional attenuation-contrast images are simultaneously acquired. The complementary information provided by both the contrast modalities suggests that enhanced material characterization is possible when performing combined data analysis. In this study, we describe how protein, lipid, and water concentrations in each 3D voxel can be quantified by vector decomposition. Experimental results of dairy products, porcine fat and rind, and different human soft tissue types are presented. The results demonstrate the potential of phase-contrast imaging as a new analysis tool. The 3D representations of protein, lipid, and water contents open up new opportunities in the fields of biology, medicine, and food science.  相似文献   

3.
Tao Q  Li D  Zhang L  Luo S 《PloS one》2012,7(6):e39936
The purpose of this paper is to report the noninvasive imaging of hepatic tumors without contrast agents. Both normal tissues and tumor tissues can be detected, and tumor tissues in different stages can be classified quantitatively. We implanted BEL-7402 human hepatocellular carcinoma cells into the livers of nude mice and then imaged the livers using X-ray in-line phase-contrast imaging (ILPCI). The projection images' texture feature based on gray level co-occurrence matrix (GLCM) and dual-tree complex wavelet transforms (DTCWT) were extracted to discriminate normal tissues and tumor tissues. Different stages of hepatic tumors were classified using support vector machines (SVM). Images of livers from nude mice sacrificed 6 days after inoculation with cancer cells show diffuse distribution of the tumor tissue, but images of livers from nude mice sacrificed 9, 12, or 15 days after inoculation with cancer cells show necrotic lumps in the tumor tissue. The results of the principal component analysis (PCA) of the texture features based on GLCM of normal regions were positive, but those of tumor regions were negative. The results of PCA of the texture features based on DTCWT of normal regions were greater than those of tumor regions. The values of the texture features in low-frequency coefficient images increased monotonically with the growth of the tumors. Different stages of liver tumors can be classified using SVM, and the accuracy is 83.33%. Noninvasive and micron-scale imaging can be achieved by X-ray ILPCI. We can observe hepatic tumors and small vessels from the phase-contrast images. This new imaging approach for hepatic cancer is effective and has potential use in the early detection and classification of hepatic tumors.  相似文献   

4.
X-ray phase-contrast imaging shows improved soft-tissue contrast compared to standard absorption-based X-ray imaging. Especially the grating-based method seems to be one promising candidate for clinical implementation due to its extendibility to standard laboratory X-ray sources. Therefore the purpose of our study was to evaluate the potential of grating-based phase-contrast computed tomography in combination with a novel bi-lateral denoising method for imaging of focal liver lesions in an ex vivo feasibility study. Our study shows that grating-based phase-contrast CT (PCCT) significantly increases the soft-tissue contrast in the ex vivo liver specimens. Combining the information of both signals – absorption and phase-contrast – the bi-lateral filtering leads to an improvement of lesion detectability and higher contrast-to-noise ratios. The normal and the pathological tissue can be clearly delineated and even internal structures of the pathological tissue can be visualized, being invisible in the absorption-based CT alone. Histopathology confirmed the presence of the corresponding findings in the analyzed tissue. The results give strong evidence for a sufficiently high contrast for different liver lesions using non-contrast-enhanced PCCT. Thus, ex vivo imaging of liver lesions is possible with a polychromatic X-ray source and at a spatial resolution of ∼100 µm. The post-processing with the novel bi-lateral denoising method improves the image quality by combining the information from the absorption and the phase-contrast images.  相似文献   

5.
Here, we present a hybrid approach for simulating an edge illumination X-ray phase-contrast imaging (EIXPCi) set-up using graphics processor units (GPU) with a high degree of accuracy. In this study, the applicability of pixel, mesh and non-uniform rational B-splines (NURBS) objects to carry out realistic maps of X-ray phase-contrast distribution at a human scale is accounted for by using numerical anthropomorphic phantoms and a very fast and robust simulation framework which integrates total interaction probabilities along selected X-ray paths. We exploit the mathematical and algorithmic properties of NURBS and describe how to represent human scale phantoms in an edge illumination X-ray phase-contrast model. The presented implementation allows the modeling of a variety of physical interactions of x-rays with different mathematically described objects and the recording of quantities, e.g. path integrals, interaction sites and deposited energies. Furthermore, our efficient, scalable and optimized hybrid Monte Carlo and ray-tracing projector can be used in iterative reconstruction algorithms on multi GPU heterogeneous systems. The preliminary results of our innovative approach show the fine performance of an edge illumination X-ray phase-contrast medical imaging system on various human-like soft tissues with noticeably reduced computation time. Our approach to the EIXPCi modeling confirms that building a true imaging system at a human scale should be possible and the simulations presented here aim at its future development.  相似文献   

6.
New types of X-ray computed tomography (CT), fluorescent X-ray CT and phase-contrast X-ray CT are being developed for biomedical research. While fluorescent scanning X-ray CT (FXCT) can detect specific contrast elements, or endogenous iodine, at very low content (less than 400 pg iodine of tissue in a volume of 8 x 10(-6) ml), the phase-contrast X-ray CT (PCCT) is a highly sensitive imaging technique to differentiate between different biological tissue types (based on their specific gravity variation) without the use of a contrast agent. Therefore, we can expect functional diagnosis with FXCT, and high contrast, high resolution biological imaging with PCCT. In this paper, a human thyroid gland imaged by FXCT, and a metastatic human cancerous lesion depicted using PCCT are presented. The latter method used a newly manufactured, large, monolithic, X-ray interferometer, which is described in this paper in detail.  相似文献   

7.
Reliable, noninvasive imaging modalities to characterize plaque components are clinically desirable for detecting unstable coronary plaques, which cause acute coronary syndrome. Although recent clinical developments in computed tomography (CT) have enabled the visualization of luminal narrowing and calcified plaques in coronary arteries, the identification of noncalcified plaque components remains difficult. Phase-contrast X-ray CT imaging has great potentials to reveal the structures inside biological soft tissues, because its sensitivity to light elements is almost 1,000 times greater than that of absorption-contrast X-ray imaging. Moreover, a specific mass density of tissue can be estimated using phase-contrast X-ray CT. Ex vivo phase-contrast X-ray CT was performed using a synchrotron radiation source (SPring-8, Japan) to investigate atherosclerotic plaque components of apolipoprotein E-deficient mice. Samples were also histologically analyzed. Phase-contrast X-ray CT at a spatial resolution of 10-20 mum revealed atherosclerotic plaque components easily, and thin fibrous caps were detected. The specific mass densities of these plaque components were quantitatively estimated. The mass density of lipid area was significantly lower (1.011 +/- 0.001766 g/ml) than that of smooth muscle area or collagen area (1.057 +/- 0.001407 and 1.080 +/- 0.001794 g/ml, respectively). Moreover, the three-dimensional assessment of plaques could provide their anatomical information. Phase-contrast X-ray CT can estimate the tissue mass density of atherosclerotic plaques and detect lipid-rich areas. It can be a promising noninvasive technique for the investigation of plaque components and detection of unstable coronary plaques.  相似文献   

8.

Background

Fibroadenoma is the most common benign solid breast lesion type and a very common cause for histologic assessment. To justify a conservative therapy, a highly specific discrimination between fibroadenomas and other breast lesions is crucial. Phase-contrast imaging offers improved soft-tissue contrast and differentiability of fine structures combined with the potential of 3-dimensional imaging. In this study we assessed the potential of grating-based phase-contrast CT imaging for visualizing diagnostically relevant features of fibroadenomas.

Materials and Methods

Grating-based phase-contrast CT was performed on six ex-vivo formalin-fixed breast specimens containing a fibroadenoma and three samples containing benign changes that resemble fibroadenomas using Talbot Lau interferometry and a polychromatic X-ray source. Phase-contrast and simultaneously acquired absorption-based 3D-datasets were manually matched with corresponding histological slices. The visibility of diagnostically valuable features was assessed in comparison with histology as the gold-standard.

Results

In all cases, matching of grating-based phase-contrast CT images and histology was successfully completed. Grating-based phase-contrast CT showed greatly improved differentiation of fine structures and provided accurate depiction of strands of fibrous tissue within the fibroadenomas as well as of the diagnostically valuable dilated, branched ductuli of the fibroadenomas. A clear demarcation of tumor boundaries in all cases was provided by phase- but not absorption-contrast CT.

Conclusions

Pending successful translation of the technology to a clinical setting and considerable reduction of the required dose, the data presented here suggest that grating-based phase-contrast CT may be used as a supplementary non-invasive diagnostic tool in breast diagnostics. Phase-contrast CT may thus contribute to the reduction of false positive findings and reduce the recall and core biopsy rate in population-based screening. Phase-contrast CT may further be used to assist during histopathological workup, offering a 3D view of the tumor and helping to identify diagnostically valuable tissue sections within large tumors.  相似文献   

9.
Phase-contrast mammography using laboratory X-ray sources is a promising approach to overcome the relatively low sensitivity and specificity of clinical, absorption-based screening. Current research is mostly centered on identifying potential diagnostic benefits arising from phase-contrast and dark-field mammography and benchmarking the latter with conventional state-of-the-art imaging methods. So far, little effort has been made to adjust this novel imaging technique to clinical needs. In this article, we address the key points for a successful implementation to a clinical routine in the near future and present the very first dose-compatible and rapid scan-time phase-contrast mammograms of both a freshly dissected, cancer-bearing mastectomy specimen and a mammographic accreditation phantom.  相似文献   

10.
Raman imaging (RI) is a novel method of medical diagnostics of human breast cancer and has a potential to become a routine optical biopsy. Up to date the present study is the most statistically reliable Raman analysis based on data of normal, benign, and cancerous breast tissues for 146 patients. This paper present the first Raman 'optical biopsy' images of the normal and cancerous breast tissue of the same patient. The results presented here demonstrate the ability of Raman spectroscopy to accurately characterize cancer tissue and distinguish between normal (noncancerous), and cancerous types. The results provide evidence that carotenoids and lipids composition of cancerous breast tissues differs significantly from that of the surrounding noncancerous breast tissue and may be a key factor responsible for mechanisms of carcinogenesis. We have found that fatty acid composition of the cancerous breast tissue is markedly different from that of the surrounding noncancerous breast tissue. The cancerous breast tissue seems to be dominated by the metabolism products of the arachidonic acid - derived cyclic eicosanoids catalyzed by cyclooxygenase, while the noncancerous breast tissue is dominated by monounsaturated oleic acid and its derivatives.  相似文献   

11.
PurposeThe purpose of this study was to assess whether grating-based X-ray imaging may have a role in imaging of pulmonary nodules on radiographs.Materials and methodsA mouse lung containing multiple lung tumors was imaged using a small-animal scanner with a conventional X-ray source and a grating interferometer for phase-contrast imaging. We qualitatively compared the signal characteristics of lung nodules on transmission, dark-field and phase-contrast images. Furthermore, we quantitatively compared signal characteristics of lung tumors and the adjacent lung tissue and calculated the corresponding contrast-to-noise ratios.ResultsOf the 5 tumors visualized on the transmission image, 3/5 tumors were clearly visualized and 1 tumor was faintly visualized in the dark-field image as areas of decreased small angle scattering. In the phase-contrast images, 3/5 tumors were clearly visualized, while the remaining 2 tumors were faintly visualized by the phase-shift occurring at their edges. No additional tumors were visualized in either the dark-field or phase-contrast images. Compared to the adjacent lung tissue, lung tumors were characterized by a significant decrease in transmission signal (median 0.86 vs. 0.91, p = 0.04) and increase in dark-field signal (median 0.71 vs. 0.65, p = 0.04). Median contrast-to-noise ratios for the visualization of lung nodules were 4.4 for transmission images and 1.7 for dark-field images (p = 0.04).ConclusionLung nodules can be visualized on all three radiograph modalities derived from grating-based X-ray imaging. However, our initial data suggest that grating-based multimodal X-ray imaging does not increase the sensitivity of chest radiographs for the detection of lung nodules.  相似文献   

12.
Invasive cancer causes a change in density in the affected tissue, which can be visualized by x-ray phase-contrast tomography. However, the diagnostic value of this method has so far not been investigated in detail. Therefore, the purpose of this study was, in a blinded manner, to investigate whether malignancy could be revealed by non-invasive x-ray phase-contrast tomography in lymph nodes from breast cancer patients. Seventeen formalin-fixed paraffin-embedded lymph nodes from 10 female patients (age range 37–83 years) diagnosed with invasive ductal carcinomas were analyzed by X-ray phase-contrast tomography. Ten lymph nodes had metastatic deposits and 7 were benign. The phase-contrast images were analyzed according to standards for conventional CT images looking for characteristics usually only visible by pathological examinations. Histopathology was used as reference. The result of this study was that the diagnostic sensitivity of the image analysis for detecting malignancy was 100% and the specificity was 87%. The positive predictive value was 91% for detecting malignancy and the negative predictive value was 100%. We conclude that x-ray phase-contrast imaging can accurately detect density variations to obtain information regarding lymph node involvement previously inaccessible with standard absorption x-ray imaging.  相似文献   

13.
To explore the potential of grating-based x-ray phase-contrast computed tomography (CT) for preclinical research, a genetically engineered mouse model of pancreatic ductal adenocarcinoma (PDAC) was investigated. One ex-vivo mouse specimen was scanned with different grating-based phase-contrast CT imaging setups covering two different settings: i) high-resolution synchrotron radiation (SR) imaging and ii) dose-reduced imaging using either synchrotron radiation or a conventional x-ray tube source. These experimental settings were chosen to assess the potential of phase-contrast imaging for two different types of application: i) high-performance imaging for virtual microscopy applications and ii) biomedical imaging with increased soft-tissue contrast for in-vivo applications. For validation and as a reference, histological slicing and magnetic resonance imaging (MRI) were performed on the same mouse specimen. For each x-ray imaging setup, attenuation and phase-contrast images were compared visually with regard to contrast in general, and specifically concerning the recognizability of lesions and cancerous tissue. To quantitatively assess contrast, the contrast-to-noise ratios (CNR) of selected regions of interest (ROI) in the attenuation images and the phase images were analyzed and compared. It was found that both for virtual microscopy and for in-vivo applications, there is great potential for phase-contrast imaging: in the SR-based benchmarking data, fine details about tissue composition are accessible in the phase images and the visibility of solid tumor tissue under dose-reduced conditions is markedly superior in the phase images. The present study hence demonstrates improved diagnostic value with phase-contrast CT in a mouse model of a complex endogenous cancer, promoting the use and further development of grating-based phase-contrast CT for biomedical imaging applications.  相似文献   

14.
The reconstruction of the acoustic properties of a neonate finless porpoise’s head was performed using X-ray computed tomography (CT). The head of the deceased neonate porpoise was also segmented across the body axis and cut into slices. The averaged sound velocity and density were measured, and the Hounsfield units (HU) of the corresponding slices were obtained from computed tomography scanning. A regression analysis was employed to show the linear relationships between the Hounsfield unit and both sound velocity and density of samples. Furthermore, the CT imaging data were used to compare the HU value, sound velocity, density and acoustic characteristic impedance of the main tissues in the porpoise’s head. The results showed that the linear relationships between HU and both sound velocity and density were qualitatively consistent with previous studies on Indo-pacific humpback dolphins and Cuvier’s beaked whales. However, there was no significant increase of the sound velocity and acoustic impedance from the inner core to the outer layer in this neonate finless porpoise’s melon.  相似文献   

15.
《Palaeoworld》2019,28(4):562-571
Iodine staining combined with X-ray computed tomography (CT) has become a core approach in anatomy, offering three-dimensional and essentially non-destructive imaging of soft tissues. Although there have been rapid advances in methodologies and techniques, the mechanisms underlying diffusible iodine contrast-enhanced CT are not yet fully understood. The protocols for staining samples of differing sizes and tissue types have not yet been justified theoretically. Here we utilize mass transfer modeling to simulate iodine diffusion and predict iodine concentrations within distinct tissue types. We also undertake iodine staining experiments to visualize the detailed anatomy and contrast effects on whole-body avian specimens using different concentrations of iodine solution to compare with model simulation results. The simulations effectively explain most observed concentration changes in differently-sized samples over distinct iodine treatment durations. These results also provide insight into the mechanisms behind the efficacy of solution replenishment for enhancing staining effects. Both consistencies and inconsistencies between our simulation and experimental results regarding iodine concentration in tissues will inform further investigations to optimize iodine staining protocols.  相似文献   

16.
We report on the first experimental results of helical differential phase-contrast computed tomography (helical DPC-CT) with a laboratory X-ray tube source and a Talbot–Lau grating interferometer. The results experimentally verify the feasibility of helical data acquisition and reconstruction in phase-contrast imaging, in analogy to its use in clinical CT systems. This allows fast and continuous volumetric scans for long objects with lengths exceeding the dimension of the detector. Since helical CT revolutionized the field of medical CT several years ago, we anticipate that this method will bring the same significant impact on the future medical and industrial applications of X-ray DPC-CT.  相似文献   

17.
Several complementary methods able to visualize the internal structures of eyes are used in the clinical practice in the diagnosis of pathologies affecting a specific zone of the eye. Despite the significant technological progress, the visualization of the entire eyeball at micrometric resolution is yet an unsolved task both in clinical diagnostics and in laboratory research. With this respect, high resolution 3D images of the eyeball would be extremely useful, in the study of various pathologies of the retina, the lens, and of the optic nerve. In this work we combined the state-of-the-art of micro computed tomography technology with phase-contrast imaging, a recent highly sensitive technique well adapted to investigate soft tissues without the use of contrast agents; we applied the technique in the post-mortem analysis of monkey eyes, which share several similitudes with the human organ. We reported here vascular, nervous and anatomical details of monkey eyes imaged with a 3.1 × 3.1 × 3.1 µm3 voxel size as well as the first 3D visualisation of the entire globe of Macaca’s fascicularis eye. Results have also been compared with, and validated by, histological analysis.  相似文献   

18.
In order to acquire phase-contrast images with adequate contrast, conventional TEM requires large amount of defocus. Increasing the defocus improves the low-frequency components but attenuates the high-frequency ones. On the other hand, Zernike phase-contrast TEM (ZPC-TEM) can recover low-frequency components without losing the high-frequency ones under in-focus conditions. ZPC-TEM however, has another problem, especially in imaging of complex biological specimens such as cells and tissues; strong halos appear around specimen structures, and these halos hinder the interpretation of images. Due to this problem, the application of ZPC-TEM has been restricted to imaging of smaller particles. In order to improve the halo appearance, we fabricated a new quarter-wave thin film phase-plate with a smaller central hole and tested it on vitreous biological specimens. ZPC-TEM with the new plate could successfully visualize, in in-focus images, the intracellular fine features of cultured cells and brain tissues. This result indicates that reduction of the central hole diameter makes ZPC-TEM applicable on size scales ranging from protein particles to tissue sections. The application of ZPC-TEM to vitreous biological specimens will be a powerful method to advance the new field of imaging science for ultrastructures in close-to-physiological state.  相似文献   

19.
A method of selection of DNA aptamers to breast tumor tissue based on the use of postoperative material has been developed. Breast cancer tissues were used as the positive target; the negative targets included benign tumor tissue, adjacent healthy tissues, breast tissues from mastopathy patients, and also tissues of other types of malignant tumors. During selection a pool of DNA aptamers demonstrating selective binding to breast cancer cells and tissues and insignificant binding to breast benign tissues has been obtained. These DNA aptamers can be used for identification of protein markers, breast cancer diagnostics, and targeted delivery of anticancer drugs.  相似文献   

20.
Increasing attention has been focused on the use of nanostructures as contrast enhancement agents in medical imaging, especially in computed tomography (CT). To date, gold nanoparticles (GNPs) have been demonstrated to have great potential as contrast agents for CT imaging. This study was designed to evaluate any effect on X-ray attenuation that might result from employing GNPs with a variety of shapes, sizes, surface chemistries, and concentrations. Gold nanorods (GNRs) and spherical GNPs were synthesized for this application. X-ray attenuation was quantified by Hounsfield unit (HU) in CT. Our findings indicated that smaller spherical GNPs (13 nm) had higher X-ray attenuation than larger ones (60 nm) and GNRs with larger aspect ratio exhibited great effect on X-ray attenuation. Moreover, poly ethylene glycol (PEG) coating on GNRs declined X-ray attenuation as a result of limiting the aggregation of GNRs. We observed X-ray attenuation increased when mass concentration of GNPs was elevated. Overall, smaller spherical GNPs can be suggested as a better alternative to Omnipaque, a good contrast agent for CT imaging. This data can be also considered for the application of gold nanostructures in radiation dose enhancement where nanoparticles with high X-ray attenuation are applied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号