首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple high-performance liquid chromatographic procedure was developed for the determination of ranitidine in human plasma. The method entailed direct injection of the plasma samples after deproteination using perchloric acid. The chromatographic separation was accomplished with an isocratic elution using mobile phase consisting of 21 mM disodium hydrogen phosphate–triethylamine-acetonitrile (1000:60:150, v/v), pH 3.5. Analyses were run at a flow-rate of 1.3 ml/min using a μbondapak C18 column and ultraviolet detection at a wavelength of 320 nm. The method was specific and sensitive, with a quantification limit of approximately 20 ng/ml and a detection limit of 5 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery was about 96%, while the within- and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The linearity was assessed in the range of 20–1000 ng/ml plasma, with a correlation coefficient of greater than 0.999. This method has been used to analyze several hundred human plasma samples for bioavailability studies.  相似文献   

2.
A rapid and sensitive high-performance liquid chromatographic method for the determination of the novel ergoline derivatives sergolexole (compound I), its acid metabolite (compound II) and cis-n-(2-hydroxycyclopentyl)-6-methyl-1-(1-methylethyl) ergoline-8-carboxamide (LY215840, compound III) in human plasma is reported. The compounds were extracted from plasma by automated solid-phase extraction and analysed on a reversed-phase C8 column with fluorescence detection. The limit of quantification for all compounds was 10 ng/ml and the response was linear over the range 10–1000 ng/ml. Validation studies showed the method to be both repeatable and reproducible with no interference from human plasma. The method has been used to support pharmacokinetic studies and has proved to be robust and effective.  相似文献   

3.
Niosomes suggest a versatile vesicle delivery system with possible transport of drugs via topical route for skin delivery. The aim of the present research was to optimize niosome gel formulation of acyclovir and to evaluate in both in vitro and in vivo rabbit model. Niosome formulations were formulated by coacervation phase separation technique with different ratios of nonionic surfactants, phospholipids and cholesterol using 32 factorial design. Altering the surfactant concentration has influenced the drug entrapment, but not vesicle size. At high surfactant combinations, the acyclovir release from niosomes was strongly influenced by cholesterol:lecithin ratio. Ex vivo drug permeation data indicate substantial difference in flux values and was influenced by the niosome composition. Ex vivo studies using formulation (B8) for drug deposition indicate greater amount of niosome being diffused into the skin layers and formed a depot, compared to commercial acyclovir cream (control). Two distinct dermatopharmacokinetic profiles were observed, in vivo, for niosome gel formulation (B8) and control, which were analog to the profiles observed with ex vivo deposition studies. In vivo plasma drug level suggests low systemic exposure of acyclovir (Cmax: 9.44?±?2.27?ng/mL and 14.54?±?3.11?ng/mL for niosome formulation and control, respectively). Comparison of kinetic data of acyclovir in the stratum corneum and plasma signifies that the niosome formulation forms a depot in the epidermis or dermis region. This study concludes that the niosome gel formulation (B8) could be a viable vesicular system for an impressive transdermal delivery of acyclovir by topical application.  相似文献   

4.
A rapid, sensitive, specific liquid chromatographic method has been developed for the determination of therapeutic levels of ganciclovir in human plasma. Plasma (1 ml) and acyclovir (I.S.) were treated with 50% trichloroacetic acid. The supernatant was neutralized with 2 M NaOH and purified with chloroform. The aqueous phase (80 μl) was analyzed by a 3-μm Hypersil ODS C18 column with 0.04 M triethylamine–0.1 M sodium dihydrogen phosphate monohydrate as the mobile phase (1 ml/min) and ultraviolet detection at 254 nm. Calibration was linear from 50 to 10 000 ng/ml. Intra- and inter-day C.V. did no exceed 6.65%. The detection limit was about 10 ng/ml.  相似文献   

5.
A high-performance liquid chromatographic method with electrochemical detection has been developed for the simultaneous determination of epirubicin, 13-S-dihydroepirubicin, doxorubicin and 13-S-dihydrodoxorubicin in human plasma. An aliquot of 200 μl plasma, spiked with internal standard, was extracted by solid-phase extraction using polymeric adsorbent columns. Chromatography was performed using a C18 reversed-phase column with a mobile phase consisting of water–acetonitrile (71:29, v/v) containing 0.05 M Na2HPO4 and 0.05% v/v triethylamine adjusted to pH 4.6 with citric acid. Linearity of the method was obtained in the concentration range of 1–500 ng/ml for all the analytes. Analytical recoveries of the analytes ranged from 89 to 93%. The assay can be used for the simultaneous determination of the four analytes, or for epirubicin and its metabolite or doxorubicin and its metabolite, using the other parent drug as an internal standard. The method was applied to analyze human plasma samples from patients treated with epirubicin using doxorubicin as an internal standard.  相似文献   

6.
A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been described for determination of acyclovir in human serum. Since acyclovir is a polar compound and soluble in aqueous medium and practically insoluble in most of organic solvents, its analysis in biological fluids in currently published HPLC methods, involve pre-treatment of acyclovir plasma sample including deproteinization or solid phase extraction. In present method liquid-liquid extraction of acyclovir and internal standard (vanillin) is achieved using dichloromethane-isopropyl alcohol (1:1, v/v) as an extracting solvent. Analysis was carried out on ODS column using methanol-phosphate buffer (0.05 M) containing sodium dodecyl sulfate (200 mg/L) and triethylamine (2 mL/L, v/v) as mobile phase (pH=2.3; 5:95, v/v) at flow rate of 2 ml/min. The method was shown to be selective and linear into the concentration range of 10-2560 ng/mL. Accuracy and precision of the method were also studied. The limit of quantitation was evaluated to be 10 ng/mL. This method was applied in bioequivalence study of two different acyclovir preparations after administration of 400mg in 12 healthy volunteers.  相似文献   

7.
A capillary electrophoresis (CE) procedure has been developed for the determination of piracetam in human plasma. Analyses were performed on an uncoated silica capillary using borax buffer modified with the addition of α-cyclodextrin. The detection was UV, operated at 200 nm. The detection limit of the authentic samples was 1 μg/ml. The calibration curve was linear over a range of 4 to 24 μg/ml (r=0.997). Inter-assay R.S.D. was below 9.3%. The described method has been successfully applied to the quantitative determination of piracetam in human plasma and should be useful for clinical and bioavailability investigations.  相似文献   

8.
A high-performance liquid chromatographic method has been developed for the determination of penicillin-V concentrations between 0.1 and 19 μg/ml in human plasma. Penicillin-V was isolated from plasma by solid-phase extraction on a C18/OH cartridge. The extracts were injected onto a reversed-phase HPLC system. A 125×4 mm C18 column was used to separate penicillin-V from its main metabolites, 5R- and 5S-penicilloic acid and endogenous compounds. The eluent consisted of 66% 0.02 M phosphoric acid buffer, to which tetrabutylammonium dihydrogenphosphate and 34% acetonitrile were added. The column effluent was monitored by ultraviolet spectrophotometry at 269 nm. Using this method, penicillin-V concentrations in plasma could be determined with an accuracy between −5.4 and 5.2% and a precision between 0.8 and 1.6%. The method has proved to be reliable and was used in biovailability studies for the development of a new oral penicillin-V formulation.  相似文献   

9.
In this research project, a high-performance liquid chromatography (HPLC) method was developed for the determination of acyclovir (ACV) in plasma. The plasma samples, recharged with acyclovir and in presence of 5'-N-methylcarboxyamidoadenosine (MECA) as an internal standard, were purified using a solid-phase extraction technique with Waters Oasis HLB columns. The separation of the components from the extract was carried out in a LiChrospher 100 RP-18 column for further ultraviolet detection at a wavelength range of 250-260 nm. The mobile phase composition was 18% acetonitrile, sodium dodecylsulphate 5 mM and phosphate buffer at pH 2.6 with an analysis time of 13 min per sample. The average retention time for acyclovir was of 5.0 min and for the internal standard 11.2 min. The calibration curve was linear ranging between 0.05 and 1.80 microg/ml. The detection limit was 0.006 microg/ml with a quantification limit of 0.020 microg/ml. The ACV recuperation percentage for 250 microl of plasma was between 94.7 and 109.7% with a coefficient of variation not higher than 5.2%. This method was developed and validated for use in bioavailability and bioequivalence studies.  相似文献   

10.
13,14-Dihydro-17-phenyl-18,19,20-trinor-PGF-isopropyl ester (latanoprost) is a new prostaglandin drug developed for the treatment of glaucoma. In clinical trials a daily dose of 1.5 μg is effective in reducing the intraocular pressure. In toxicological studies doses from 2 μg/eye to 100 μg/eye have been used in various species. This paper reports the development and validation of a radioimmunoassay of latanoprost acid (PhXA85) and its application to toxicokinetic studies performed in monkeys. An antiserum was raised in rabbits by immunization with PhXA85 coupled to BSA at the carboxylic acid by the mixed anhydride method. The antibody titre was found to be about 1:2000 to 1:3000. The cross-reactivity with 13,14-dihydro-15(R,S)-17-phenyl-trinor-PGF, 13,14-dihydro-15(S)-17-phenyl-trinor-PGF, dinor-PhXA85, 17-phenyl-trinor-PGF, latanoprost and PGF was 46.4, 4.2, 7.6, 2.2, 0.1 and 0.039%, respectively. The intra-assay precision was between ± 7.7 and 11.7% (CV) at the level of 320 pg/ml and ±8.3 and 9.7% with 1280 pg/ml in plasma samples from man, monkey, rat and aqueous humour from human and rabbit. Similarly, the intra-assay accuracy varied between 95.9 and 102.5% and 89.0 and 109.0% for the low and high standards, respectively. The inter-assay precision and accuracy were between ±6.0 and 13.4% and 91.0 and 92.8% in the monkey plasma samples. The limit of detection was 3 pg/tube or 30 pg/ml. In a long-term study, the acid of latanoprost was rapidly cleared from plasma in monkeys treated with eye drops of latanoprost (2 × 3 μg/day) over a period of 1 year.  相似文献   

11.
Moguisteine is a novel peripheral non-narcotic antitussive agent. Pharmacokinetic studies in animal and in man showed that no unchanged drug is present in plasma, urine and faeces after oral administration. The main active metabolite, M1, is the free carboxylic acid of moguisteine, which maintains a stereogenic centre and consists of R(+)-M1 and S(−)-M1 enantiomers. M1 is partly metabolized to M2, its sulfoxidation derivative. A conventional HPLC method is described for the simultaneous determination of M1 and M2 in human plasma and urine after administration of therapeutic moguisteine doses. Plasma samples, previously acidified with phosphoric acid, are extracted with dichloromethane; urine samples are analyzed after appropriate dilution with methanol. Chromatography is performed using a Lichrosorb RP2 column and a linear gradient. M1 enantiomers can be determined in plasma extracts and urine samples by a chiral HPLC method using a β-cyclodextrin column. The analytical characteristics of both HPLC procedures proved to be adequate to analyze samples of subjects treated with therapeutic doses of moguisteine during clinical pharmacokinetic studies.  相似文献   

12.
A reversed-phase ion-pair high-performance liquid chromatography method for the determination of acyclovir and its metabolite 9-carboxymethoxymethylguanine is described. The samples are purified by reversed-phase solid-phase extraction. The components are separated on a C18 column with a mobile phase containing 18% acetonitrile, 5 mM dodecyl sulphate and 30 mM phosphate buffer, pH 2.1, and measured by fluorescence detection using an excitation wavelength of 285 nm and an emission wavelenght of 380 nm. Detection limits are 0.12 μM (plasma)) and 0.60 μM (urine) for acyclovir, and 0.26 μM (plasma) and 1.3 μM (urine) for metabolite. Correlation coefficients that were better than 0.998 were obtained normally. This analytical method, which enables simultaneous measurement of parent compound and metabolite, has been used in kinetics studies and for therapeutic drug monitoring in different patient groups with variable degrees of renal dysfunction.  相似文献   

13.
A sensitive method has been developed for the determination of the vasoactive compounds cinnarizine and flunarizine in plasma, urine and milk samples from man and animals. The procedure involves the extraction of the drugs and their internal standard from the biological samples at alkaline pH, back-extraction into sulphuric acid and re-extraction into the organic phase (heptane—isoamyl alcohol).The analyses were carried out by gas chromatography using a nitrogen-selective thermionic specific detector. The detection limit was 0.5 ng/ml of biological fluid and extraction recoveries were sufficiently high (87–94%).The method was applied to plasma samples from bioavailability studies of both cinnarizine and flunarizine in healthy volunteers, and to plasma, urine and milk samples from flunarizine-treated dogs.  相似文献   

14.
An isocratic reversed-phase high-performance liquid chromatographic method for the simultaneous determination of denaverine and its N-monodemethyl metabolite (MD 6) in human plasma is described. The assay involves the extraction with an n-heptane–2-propanol mixture (9:1, v/v) followed by back extraction into 12.5% (w/w) phosphoric acid. The analytes of interest and the internal standard were separated on a Superspher RP8 column using a mobile phase of acetonitrile–0.12 M NH4H2PO4–tetrahydrofuran (24:17.2:1, v/v), adjusted to pH 3 with 85% (w/w) phosphoric acid. Ultraviolet detection was used at an operational wavelength of 220 nm. The retention times of MD 6, denaverine and the internal standard were 5.1, 6.3 and 10.2 min, respectively. The assay was validated according to international requirements and was found to be specific, accurate and precise with a linear range of 2.5–150 ng/ml for denaverine and MD 6. Extraction recoveries for denaverine and MD 6 ranged from 44 to 49% and from 42 to 47%, respectively. The stability of denaverine and MD 6 in plasma was demonstrated after 24 h storage at room temperature, after three freeze–thaw cycles and after 7 months frozen storage below −20°C. The stability of processed samples in the autosampler at room temperature was confirmed after 24 h storage. The analytical method has been applied to analyses of plasma samples from a pharmacokinetic study in man.  相似文献   

15.
A method was developed for the simultaneous determination of cyclandelate and mandelic acid concentrations in plasma, involving extraction from plasma followed by trimethylsilylation and chromatography of the derivatives on a glass capillary column with hydrogen flame-ionization detection. Calibration graphs were linear down to at least 20 μg/ml for each substance. The precision was excellent with a pooled relative standard deviation of 6.3% and 6.4% for cyclandelate and mandelic acid serum samples, respectively. Concentrations below 500 ng/ml of each substance could be detected in human plasma. The method was developed for use in bioavailability and metabolism studies.  相似文献   

16.
Puerarin, an isoflavone C-glycoside, has been identified as the major active component isolated from Pueraria lobata (Kudzu) responsible for suppression of alcohol drinking. In order to conduct clinical studies of Kudzu's efficacy, a method for measuring its bioavailability and pharmacokinetic profile is needed. We have developed a gradient reversed-phase HPLC system for pharmacokinetic study of puerarin in human plasma. Solid-phase extraction was performed on an abselut Nexus cartridge (60 mg/3 ml) possessing adsorbent function with a recovery of >97% and 4-hydroxybenzoic acid was used as an internal standard. The HPLC assay was performed on a YMC ODS-A column (150 mm x 4.6mm i.d., 5 microm particle size). The HPLC mobile phase consisted of methanol/0.5% acetic acid with 20-35% methanol gradient at a flow-rate of 0.8 ml/min. The UV wavelength was set at 254 nm. Calibration of the overall analytical procedure gave a linear signal (r>0.999) over a puerarin concentration range of 5-500 ng/ml in human plasma. The lower limit of quantification was ca. at 8 ng/ml of puerarin in plasma. The detection limit (defined as signal-to-noise ratio of about 3) was approximately 3 ng/ml. The preliminary pharmacokinetic study after oral administration of the Kudzu capsules containing 400mg of puerarin to a healthy volunteer confirmed that the present method was suitable for determining puerarin in human plasma.  相似文献   

17.
A high-performance liquid chromatographic method has been developed and tested for simultaneous extraction, elution and determination of doxorubicin and prochlorperazine content in human plasma samples. The procedure consists of extraction through a conditioned C18 solid-phase extraction cartridge, elution from a Spherisorb C8 reversed-phase column by an isocratic mobile phase (60% acetonitrile, 15% methanol and 25% buffer) followed by detection with electrochemical and fluorescence detectors. Recovery of doxorubicin and prochlorperazine from pooled human plasma samples (n=3) containing 100 ng/ml of the two drugs was 77.8±3.5% and 89.1±6.0%, respectively. The lower limits of quantitation for doxorubicin and prochlorperazine in plasma samples were 6.25 ng/ml and 10 ng/ml, respectively. A linear calibration curve was obtained for up to 2 μg/ml of doxorubicin and prochlorperazine. This combination method may be of particular value in clinical studies where phenothiazines such as prochlorperazine are used to enhance retention of doxorubicin in drug resistant tumor cells.  相似文献   

18.
A new and specific HPLC–DAD method for the direct determination of Prulifloxacin and its active metabolite, Ulifloxacin, in human plasma has been developed. Plasma samples were analysed after a simple solid phase extraction (SPE) clean-up using a new HILIC stationary phase based high-performance liquid chromatography (HPLC) column and an ammonium acetate buffer (5?mM, pH 5.8)/acetonitrile (both with 1% Et3N, v/v) mobile phase in isocratic elution mode, with Danofloxacin as the internal standard. Detection was performed using DAD from 200 to 500?nm and quantitative analyses were carried out at 278?nm. The LOQ of the method was 1?μg/mL of the cited analytes and the calibration curve showed a good linearity up to 25?μg/mL. For both analytes the precision (RSD%) and the trueness (bias%) of the method fulfil with International Guidelines. The method was applied for stability studies, at three QC concentration levels, in human plasma samples stored at different temperature of?+?25,?+?4 and ?20?°C in order to evaluate plasma stability profiles.  相似文献   

19.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantitation of tadalafil (I) in human plasma, a new selective, reversible phosphodiesterase 5 inhibitor. The analyte and internal standard (sildenafil, II) were extracted by liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on reverse phase Xterra MS C18 column with a mobile phase of 10mM ammonium formate/acetonitrile (10/90, v/v, pH adjusted to 3.0 with formic acid). The protonate of analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 390.4 --> 268.0 and m/z 475.5 --> 58.3 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 10-1000 ng/mL for tadalafil in human plasma. The lower limit of quantitation was 10 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. Run time of 1.2 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

20.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of dutasteride (I), a potent and the first specific dual inhibitor of 5alpha-reductase, in human plasma. The analyte and internal standard (finasteride (II)) were extracted by liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reverse phase Xterra MS C18 column with a mobile phase of 10 mM ammonium formate/acetonitrile (15/85, v/v, pH adjusted to 3.0 with formic acid). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 529.5 --> 461.5 and m/z 373.3 --> 317.4 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.1-25.0 ng/mL for dutasteride in human plasma. The lower limit of quantitation was 100 pg/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 1.2 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples/day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏