首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
Two different automated immunoanalysis systems are presented. Both are based on the principles of flow-injection analysis and were developed to provide reliable, rapid monitoring of relevant proteins in animal cell cultivation processes. One system uses a turbidimetric analysis, and the other employs a heterogeneous chemistry with immobilized immunocomponents. For both systems, the analysis time is in the range of a few minutes, and a complete analysis cycle, including triplicate analyses and various washing steps, is in the range of 20–30 minutes. Samples from cultivation processes can be analyzed directly without dilution. Quantitation of proteins such as rt-PA or monoclonal antibodies can be performed over an analyte concentration range of 1–1000 mg/L. Both systems were compared to conventional ELISA assays on microtiter plates. The turbidimetric analysis system also included a biosensor for simultaneous glucose determination.  相似文献   

2.
L. Ball  A. Jones  P. Boogaard  W. Will  P. Aston 《Biomarkers》2013,18(2-3):127-137
Abstract

Propylene oxide (PO) is an important industrial compound and a directly acting mutagen. Human exposure to PO can be monitored by the determination of haemoglobin adducts. An immunoassay that quantifies the N-terminal adduct N-(2-hydroxypropyl)valine in whole haemoglobin was developed and its potential usefulness as a tool for biologically monitoring occupational exposure was demonstrated. Analytical reliability was confirmed in a comparative study with GC-MS (range 3.7–992 nmol g?1 haemoglobin (Hb), correlation coefficient 0.99, n=10). The assay has been configured as a competitive enzyme-linked immunosorbent assay to facilitate the rapid throughput of samples. The assay employs a whole blood matrix and has a working range of 2–250 pmol g?1 Hb. It does not appear to be affected by structurally similar metabolites and has been used to determine adducts in human blood samples. The first results in potentially exposed workers indicate the assay's high potential usefulness in routine occupational biomonitoring of exposure to PO.  相似文献   

3.
Ethylene oxide (EO) is an important industrial compound and a directly acting mutagen. Human exposure to it can be monitored by the determination of haemoglobin (Hb) adducts. An immunoassay that quantifies the N-terminal adduct N-(2-hydroxyethyl)valine in whole blood was developed and its potential usefulness as a tool for biologically monitoring occupational exposure demonstrated. Analytical reliability was confirmed in a comparative study with gas chromatography-mass spectrometry (range 0.040-589 nmol g-1 Hb, correlation coefficient 0.98, n=10). The assay was configured as a competitive enzyme-linked immunosorbent assay to facilitate the rapid throughput of samples. The assay uses a whole blood matrix and has a working range of 10-10 000 pmol N-(2-hydroxethyl)valine g-1 Hb. The assay does not appear to be affected by structurally similar metabolites and has been used to determine adducts in human blood samples. The first results from potentially exposed workers indicate the assay might be a powerful tool for the routine occupational biomonitoring of EO exposure.  相似文献   

4.
Ethylene oxide (EO) is an important industrial compound and a directly acting mutagen. Human exposure to it can be monitored by the determination of haemoglobin (Hb) adducts. An immunoassay that quantifies the N-terminal adduct N-(2-hydroxyethyl)valine in whole blood was developed and its potential usefulness as a tool for biologically monitoring occupational exposure demonstrated. Analytical reliability was confirmed in a comparative study with gas chromatography-mass spectrometry (range 0.040–589?nmol?g?1 Hb, correlation coefficient 0.98, n=10). The assay was configured as a competitive enzyme-linked immunosorbent assay to facilitate the rapid throughput of samples. The assay uses a whole blood matrix and has a working range of 10–10?000 pmol N-(2-hydroxethyl)valine?g?1 Hb. The assay does not appear to be affected by structurally similar metabolites and has been used to determine adducts in human blood samples. The first results from potentially exposed workers indicate the assay might be a powerful tool for the routine occupational biomonitoring of EO exposure.  相似文献   

5.
Recently we have described the design and operation of a miniature bioreactor system in which 4-16 fermentations can be performed (Gill et al., Biochem Eng J 39:164-176, 2008). Here we report on the use of thermal profiling techniques for parallel on-line monitoring of cell growth in these bioreactors based on the natural heat generated by microbial culture. Results show that the integrated heat profile during E. coli TOP10 pQR239 fermentations followed the same pattern as off-line optical density (OD) measurements. The maximum specific growth rates calculated from off-line OD and on-line thermal profiling data were in good agreement, at 0.66+/-0.04 and 0.69+/-0.05 h(-1) respectively. The combination of a parallel miniature bioreactor system with a non-invasive on-line technique for estimation of culture kinetic parameters provides a valuable approach for the rapid optimisation of microbial fermentation processes.  相似文献   

6.
Concentrations of substrates, glucose, and ammionia in biological processes have been on-line monitored by using glucose-flow injection (FIA) and ammonia-FIA systems. Based on the on-line monitored data the concentrations of substrates have been controlled by an on-off controller, a PID controller, and a neural network (NN) based controller. A simulation program has been developed to test the control quality of each controller and to estimate the control parameters. The on-off controller often produced high oscillations at the set point due to its low robustness. The control quality of a PID controller could have been improved by a high analysis frequency and by a short residence time of sample in a FIA system. A NN-based controller with 3 layers has been developed, and a 3(input)-2(hidden)-1(output) network structure has been found to be optimal for the NN-based controller. The performance of the three controllers has been tested in a simulated process as well as in a cultivation process ofSaccharomyces cerevisiae, and the performance has also been compared to simulation results. The NN-based controller with the 3-2-1 network structure was robust and stable against some disturbances, such as a sudden injection of distilled water into a biological process.  相似文献   

7.
The paper presents the study correlating the profile of on-line monitoring parameters and nutrient removal in an intermittent cyclic process bioreactor (ICPBR) system, thereby utilizing the parameters as operational tool. A laboratory scale ICPBR was employed to treat low C/N ratio domestic wastewater from a township. The study was conducted for correlating biological nutrient removal and on-line monitored parameters pH, dissolved oxygen (DO) and oxidation-reduction potential (ORP). The results revealed that pH, DO and ORP related with the dynamic behavior of nutrient concentration (NH4-N, NO3-N, and PO4-P) during treatment in an ICPBR system. The variation in pH and ORP of the reactor liquor correlate to conversion of ammonia (NH4-N) and nitrate (NO3-N) concentrations, respectively. As the bioconversion of ammonia nitrogen and phosphorus are related to the varying profile of the on-line monitored parameters, the profiles could possibly be used as onsite process control parameters.  相似文献   

8.
Standard enzyme immunoassays (EIAs) require washing steps to remove excess enzyme-antibody complexes. Such washing is laborious, lengthens assay time, and increases assay scatter. Recently, so-called precipitate-enhanced immunoassays (PEIAs) were introduced. Instead of color formation due to enzymatic conversion of a chromogenic substrate, this technique measures the rate of precipitate formation due to conversion of a substrate with a precipitating product. Such precipitation can be measured in the presence of active enzyme-antibody complexes in the buffer and no washing is required. In the present study this technique was used in a one-step PEIA, without washing steps, for the measurement of plasma concentrations of fatty-acid-binding protein. Horseradish peroxidase was used as tagging enzyme and diaminobenzidine as precipitating substrate. Precipitate formation was measured by ellipsometry. Assay time of the one-step PEIA was much shorter than that for an existing standard EIA. Test results can be obtained within minutes, depending on the sensitivity required. Assay precision of the one-step PEIA was better than that of the standard EIA. In the one-step assay, loss of surface-bound conjugate due to washing is prevented, which could explain part of the improved sensitivity compared to that of the two-step PEIA. More importantly, the presence of substrate-converting enzyme-antibody complexes in the buffer caused a large enhancement of precipitation.  相似文献   

9.
A new immunoassay method called specific analyte labeling and recapture assay (SALRA) to quantitatively measure protein abundance was developed, and the assay conditions were optimized. The key features of this method include labeling the antigen bound to the capture antibody, eluting the labeled antigen, and recapturing it by the same capture antibody on the detection plate. The reporter molecules on the labeled antigen provide a convenient and reliable means for signal detection. We demonstrated that the dose-response curve of SALRA was comparable to that of sandwich enzyme-linked immunosorbent assay (ELISA) and better than that of the antigen direct labeling method. In addition, multiple proteins can be measured simultaneously by SALRA. Using the SALRA method, the detection limit for most of the cytokines tested was approximately 0.01 ng/ml. Further SALRA tests on interleukin 6 (IL-6) showed the linear dose-response was 3.3 to 0.01 ng/ml, the accuracy of the test was 71 to 91%, the intraassay variation was 3.6 to 7.4%, and the interassay variation was 3.8 to 10.0%. The applications of SALRA include quantitatively measuring proteins for which there are no ELISA tools available and providing a new platform for protein microarrays.  相似文献   

10.
Cytokinins occur in a diversity of forms and determination of their individual levels requires extensive purification. However, determination of the total level of each major base in free, riboside and nucleotide forms would often be adequate. Hence, a methanolysis procedure which releases cytokinin bases from 9-ribosyl derivatives was developed and applied to plant extracts. A simple procedure, involving low pressure column chromatography, for purification of the cytokinin bases in treated extracts, and a scintillation proximity immunoassay for their quantification, were developed. The total level of each cytokinin base [N6-(2-isopentenyl)adenine, zeatin and dihydrozeatin] in free and ribosylated forms determined by these methods is reported for several plant tissues and the results are compared with those obtained after additional purification by HPLC. Values for zeatin were not changed by HPLC but isopentenyl-adenine and dihydrozeatin levels were usually reduced indicating the presence of unknown compounds which cross-react in the immunoassay. Modifications to the above purification method to quantify O-glucosyl cytokinins are also described.
The methods described facilitate the quantification of the total amount of each cytokinin base in forms closely associated with cytokinin action, and the detection of cytokinin biosynthesis by labelled precursor incorporation.  相似文献   

11.
The importance of mammalian cell cultures for biotechnological production processes is steadily increasing, despite the high demands of these organisms on their culture conditions. Efforts towards a more efficient bioprocess generally concentrate on maximizing the culture's life time, the cell number, and the product concentration. Here recombinant BHK 21 c13 cells are used to produce rh-AT III, an anticoagulant of high therapeutic value. The influence of the process mode (batch, repeated batch, continuous perfusion) and the process temperature (30°C vs. 37°C) on the above mentioned parameters is investigated. It is possible to increase the length of the culture from 140 h (batch) to more than 500 h (continuous perfusion culture), while concomitantly increasing the cell density from 0.72 106/ml (batch) to 2.27 106/ml (repeated batch) and 2.87 106/ml (continuous perfusion culture). The accumulation of toxic metabolites, such as lactate, can be curtailed by reducing the bioreactor temperature from 37°C to 30°C during the later part of the exponential growth phase. Fast and reliable product monitoring became essential during process optimization. Capillary zone electrophoresis (CZE) in uncoated fused silica capillaries was studied for that purpose and compared to the standard ELISA. Under optimized conditions an AT III quantification could be done within 2 min with CZE. The detection limit was 5 g/ml. A relative standard deviation of less than 0.9% was calculated. The detection limit could be lowered by one order of magnitude by using a two dimensional system, where an liquid chromatographic (LC) system is coupled to the CZE. Concomitantly the resolution is improved. The two-dimensional analysis required 5 min. Membrane adsorbers (MA) were used as stationary phase in the LC-system, to allow the application of high flow rates (5–10 ml/min). The correlation between the LC-CZE analysis and the standard AT III-ELISA was excellent, with r2: 0.965. Using the assay for at line product monitoring, it is shown, that the process temperature is of no consequence for the productivity whereas the process mode strongly influences this parameter.  相似文献   

12.
Plasma renin activity (PRA) is a well-established biomarker for assessing the efficacy of various antihypertensive agents such as direct renin inhibitors, angiotensin receptor blockers, and angiotensin-converting enzyme inhibitors (ACEIs). PRA measurements are obtained through the detection and quantification of angiotensin I (Ang I) produced by the action of renin on its natural substrate angiotensinogen. The most accepted and reproducible method for PRA measurement uses an antibody capture Ang I methodology that employs specific antibodies that recognize and protect Ang I against angiotensinase activities contained in plasma. The amount of Ang I is then quantified by either radioimmunoassay (RIA) or enzyme immunoassay (EIA). In the current report, we describe the optimization of a novel homogeneous immunoassay based on the AlphaScreen technology for the detection and quantification of antibody-captured Ang I using AlphaLISA acceptor beads in buffer and in the plasma of various species (human, rat, and mouse). Ex vivo measurements of renin activity were performed using 10 μl or less of a reaction mixture, and concentrations as low as 1 nM Ang I were quantified. Titration curves obtained for the quantification of Ang I in buffer and plasma gave similar EC50 values of 5.6 and 14.4 nM, respectively. Both matrices generated an equivalent dynamic range that varies from approximately 1 to 50 nM. Renin inhibitors have been successfully titrated and IC50 values obtained correlated well with those obtained using EIA methodology (r2 = 0.80). This assay is sensitive, robust, fast, and less tedious than measurements performed using nonhomogeneous EIA. The AlphaLISA methodology is homogeneous, does not require wash steps prior to the addition of reagents, and does not generate radioactive waste.  相似文献   

13.
The development of a highly sensitive analytical method for oxytocin could be useful in the diagnosis and treatment of autistic spectrum disorder. We previously developed a colorimetric enzyme immunoassay (EIA) for plasma oxytocin measurement. In this study, we developed a method to measure oxytocin concentrations using a higher sensitivity bioluminescent EIA. Biotinylated oxytocin bridged with five lysine residues was used in a competitive format. The standard curve range for oxytocin was 1.0 to 1000 pg/assay. In addition, there was good correlation between the colorimetric and bioluminescent immunoassays in terms of measured oxytocin concentration (r = 0.9665, n = 48). The bioluminescent EIA for plasma oxytocin was more rapid and provided higher sensitivity than the colorimetric immunoassay, making it suitable for clinical application.  相似文献   

14.
Direct monitoring of recognition processes at the molecular level is a valuable tool for studying reaction kinetics to assess affinity constants (e.g. drugs to receptors) and for designing rapid single step immunoassays. Methods currently used to gain information about binding processes predominantly depend on surface plasmon resonance. These systems use excitation with coherent light in attenuated total reflection geometry to obtain discrimination between surface-bound and free molecules in solution. Therefore labeling of the compounds is not necessary, but due to the complexity of the measuring setup the method is rather costly. In this contribution we present a simple method for performing kinetic single step biorecognition assays with fluorophore labeled compounds using the fluorescence enhancement properties of surface bound silver colloids. Silver colloids are bound to standard microplates via silanization of the plastic surface. Fluorophores close to this colloid coated surface show a significant gain in fluorescence compared to fluorophores farther away in the bulk solution. Therefore discrimination between surface bound and free fluorophores is possible and the binding of, for example, fluorophore labeled antibodies to antigens immobilized on the colloid surface results in increasing fluorescence intensity. Utilization of standard microplates makes this method fully compatible with conventional microplate processing and reading devices. Neither excitation with coherent laser light nor ATR geometry is required, the measurement is performed in a standard fluorescence microplate reader in front face geometry with a xenon flash lamp as excitation source. Methods for the preparation of colloid-coated microplates and fluorescence-enhanced biorecognition assays are presented. Additionally the dependence of the system performance on the structure and properties of the metal colloid coated surface is described. A two-component biorecognition model system shows a detection limit in the subnanomolar range. The ease of colloid-surface preparation and the high sensitivity makes fluorescence enhancement at colloid-coated microplates a valuable tool for studying reaction kinetics and performing rapid single-step immunoassays.  相似文献   

15.
A solid-phase assay for detecting the binding of cartilage proteoglycan (PG) to hyaluronic acid (HA) is described. In the assay, HA is immobilized on protamine-treated microtiter wells, the wells are incubated with PG monomer and antibody to PG monomer, and then an ELISA system is used to detect binding of the PG to HA. The specificity of the assay is indicated by the failure to detect PG binding to chondroitin sulfate or albumin-coated microtiter wells, the absence of binding with tryptic fragments of PG monomer other than the HA-binding segment, the loss of binding after reduction and alkylation of PG monomer, and the inhibition of binding by preincubation of PG monomer with small amounts of HA. In contrast to the HA-PG interaction in solution, hyaluronidase digestion of HA does not affect its ability to inhibit the reaction of PG monomer with immobilized HA. The microtiter well-based assay appears to be a rapid, simple, and potentially versatile method for studying interactions with HA.  相似文献   

16.
In many biological reactors bicarbonate is the major species determining pH buffering capacity, or alkalinity. In anaerobic digesters bicarbonate levels should be within 10 to 50 mM for stable operation. Bicarbonate alkalinity in wastewater treatment processes in routinely measured off-line titrimetrically. Recently we have described the principle of a novel on-line method of measuring bicarbonate alkalinity. In the prototype device described here, a continuous stream (15 cm(3) min(-1)) of the substrate to be monitored was saturated with gaseous CO2, acidified by the addition of excess acid, and the rate of carbon dioxide evolution, proportional to the concentration of bicarbonate/carbonate in the liquid flow, continuously measured by a sensitive gas meter. The instrument was robust and its response was satisfactory for wastewater treatment process control applications, with linearity in the range 5 to 50 mM HCO3(-), a response time in the order of 30 min, and accuracy of the order of 7% in the concentration range 5 to 50 mM sodium bicarbonate. The device was not affected by interference from volatile fatty acids, does not make use of pH probes which in many wastes are subject to fouling, and may form the basis of a digester control strategy. (c) 1994 John Wiley & Sons, Inc.  相似文献   

17.
This article demonstrates the successful in situ real-time monitoring of the cell concentration of Perilla frutescens in a bioreactor by using a laser turbidimeter. It was found that turbidity measurements at 780 nm with the laser sensor were hardly affected by the red color of the anthocyanin produced by P. frutescens cells, nor by the aeration rate or agitation speed within the ranges investigated. There was an excellent linear relationship, with a correlation coefficient (r(2)) higher than 0.99, between the sensor's response and the cell concentration. The whole growth stage of the cells, i.e., lag, logarithmic, and stationary phases, in bioreactor cultivations, could be satisfactorily estimated on-line by means of the in situ turbidimeter. However, during the declining phase of the cells, an apparent deviation was observed between the on-line estimations and off-line measurements of cell concentrations by dry cell weight, while the wet cell weight could be estimated by the same turbidimeter system. We found that this deviation was caused by a decrease in the cell density due to an increase of the individual cell volume and a decrease of the cell dry weight during the declining phase. (c) 1993 John Wiley & Sons, Inc.  相似文献   

18.
Two liquid sampling systems, which are set in the bioreactor and can be sterilized in place, are described. They are composed primarily of an inorganic membrane filter which is either stationary or is set in a rotating motion. These systems have been tested during three types of fermentation processes (ethanol, lactic acid, and polysaccharide productions). The rotating system gave better filtration performances than the stationary sampler which can be used only in alcoholic fermentation. The rotating sampler was coupled with a high-pressure liquid chromatograph for the on-line quantitation of the major compounds present in the filtrate. The results are in good agreement with those obtained from off-line analysis on samples taken manually. (c) 1992 John Wiley & Sons, Inc.  相似文献   

19.
Dissolved carbon dioxide (dCO2) is a well-known critical parameter in bioprocesses due to its significant impact on cell metabolism and on product quality attributes. Processes run at small-scale faces many challenges due to limited options for modular sensors for online monitoring and control. Traditional sensors are bulky, costly, and invasive in nature and do not fit in small-scale systems. In this study, we present the implementation of a novel, rate-based technique for real-time monitoring of dCO2 in bioprocesses. A silicone sampling probe that allows the diffusion of CO2 through its wall was inserted inside a shake flask/bioreactor and then flushed with air to remove the CO2 that had diffused into the probe from the culture broth (sensor was calibrated using air as zero-point calibration). The gas inside the probe was then allowed to recirculate through gas-impermeable tubing to a CO2 monitor. We have shown that by measuring the initial diffusion rate of CO2 into the sampling probe we were able to determine the partial pressure of the dCO2 in the culture. This technique can be readily automated, and measurements can be made in minutes. Demonstration experiments conducted with baker's yeast and Yarrowia lipolytica yeast cells in both shake flasks and mini bioreactors showed that it can monitor dCO2 in real-time. Using the proposed sensor, we successfully implemented a dCO2-based control scheme, which resulted in significant improvement in process performance.  相似文献   

20.
On-line monitoring of hybridoma cell growth using a laser turbidity sensor   总被引:3,自引:0,他引:3  
A high-sensitivity turbidity probe was used for on-line monitoring of the cell concentration in batch hybridoma cultivation. Good correlation between off-line cell counts and the linearized sensor signal was found. The quality of the signal was sufficiently high to provide for on-line estimation of the specific growth rate using an efficient filtering procedure. These positive results suggest that such laser turbidity sensors will facilitate development of systems for on-line monitoring and control of animal cell cultivations. (c) 1992 John Wiley & Sons, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号