首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The characteristics of the mass spectra of vitamin D3 related compounds were investigated by GC–MS and LC–MS using 22-oxacalcitriol (OCT), an analog of 1,25-dihydroxyvitamin D3, and related compounds. Fragmentation during GC–MS (electron impact ionization) of TMS-derivatives of OCT and the postulated metabolites gave useful structural information concerning the vitamin D3-skeleton and its side-chain, especially with respect to the oxidation positions of metabolites. In contrast, few fragment ions were observed in LC–MS (atmospheric pressure chemical ionization), showing that LC–MS gave poor structural information, except for molecular mass. However, when comparing the signal-to-noise ratio (S/N) observed during GC–MS and LC–MS analysis for OCT in plasma extracts, the S/N in LC–MS was over ten-times greater than in GC–MS, possibly due to the low recovery on derivatization and thermal-isomerization in GC–MS. Furthermore, both the GC–MS and the LC–MS allowed the analysis of many postulated metabolites in a single injection without any prior isolation of target metabolites from biological fluids by LC. These results suggest that GC–MS and LC–MS analysis for vitamin D3 related compounds such as OCT each have unique and distinct advantages. Therefore, the complementary use of both techniques enables the rapid and detailed characterization of vitamin D3 related compounds.  相似文献   

2.
Positive ion mass spectra were obtained from several coumarin oral anticoagulants (phenprocoumon, warfarin, acenocoumarol and dicoumarol) and derivatives by liquid chromatography—thermospray mass spectrometry (LC—TSP-MS) and liquid chromatography—electron impact mass spectrometry (LC—EI-MS) to assess the use of LC—MS methods for the determination of these compounds in biological materials. LC—TSP mass spectra showed a single [M + 1]+ ion with no fragmentation; LC—EI mass spectra showed fragment ions which were similar in mass and relative intensities to those obtained by conventional EI-MS. These data should serve as a basis for the development of LC—MS methods for the qualitative and quantitative analysis of coumarin anticoagulants in biological samples. LC—TSP-MS was applied to the determination of phenprocoumon in a plasma extract from an anticoagulated patient.  相似文献   

3.
In an isotope dilution assay, prostaglandin (PG) E2, 6-keto-PGF, thromboxane (Tx) B2 and their metabolites PGE-M (11α-hydroxy-9,15-dioxo-2,3,4,5,20-pentanor-19-carboxyprostanoic acid), 2,3-dinor-6-keto-PGF, 2,3-dinor-TxB2 and 11-dehydro-TxB2 were determined in urine by gas chromatography—triple stage quadrupole mass spectrometry (GC—MS—MS). After addition of deuterated internal standards, the prostaglandins were derivatized to their methoximes and extracted with ethyl acetate—hexane. The sample was further derivatized to the pentafluorobenzylesters and purified by thin-layer chromatography (TLC). Three zones were scraped from the TLC plate. The prostanoid derivatives were converted to their trimethylsilyl ethers and the products were quantified by GC—MS—MS. In each run, two or three prostanoids were determined.  相似文献   

4.
A specific method for the determination of erythromycin 2'-ethylsuccinate (EM-ES) in plasma is described. The method involves a liquid—liquid extraction procedure followed by the analysis of extracts using phase-system switching (PSS) continuous-flow fast atom bombardment (CF-FAB) liquid chromatography—mass spectrometry (LC—MS). In PSS EM-ES is enriched after analytical separation on a short trapping column, from which it is desorbed to the LC—MS interface. In this way, favourable mobile phases can be used for the LC separation and for the MS detection. Using the PSS approach a flow-rate reduction from 1.0 ml/min in the LC system to 15 μl/min going into the mass spectrometer was achieved without splitting. The determination limit for EM-ES was 0.1 μg/ml.  相似文献   

5.
Pentachlorophenyl (PCP) esters of five free bile acids (FBA) were obtained by reacting the FBA and Kovacs' complex (KC) in a 1:8 molar ratio in acetone at 65°C, and were purified by column chromatography on silica gel. The esters were crystallized from benzene—hexane, derivatized as trimethylsilyl ethers for gas chromatography on a DB-1 capillary column and for gas chromatography—mass spectrometry with a DB-5 column, and mass spectrometry (MS) in the electron-impact (EI) positive-ion mode at 70 eV. The reaction is specific for FBA even in the presence of glycine and taurine conjugates of bile acids. The PCP esters were treated with benzylamine in chloroform or methanol to produce N-benzyl derivatives of FBA. The N-benzylamides were separated by high-performance liquid chromatography (HPLC) on a 4-μm Nova-Pak C18 column, studied by thermospray—LC—MS, and in the direct insertion probe—EI positive-ion mode.  相似文献   

6.
The applicability of LC–MS/MS in precursor ion scan mode for the detection of urinary stanozolol metabolites has been studied. The product ion at m/z 81 has been selected as specific for stanozolol metabolites without a modification in A- or N-rings and the product ions at m/z 97 and 145 for the metabolites hydroxylated in the N-ring and 4-hydroxy-stanozolol metabolites, respectively. Under these conditions, the parent drug and up to 15 metabolites were found in a positive doping test sample. The study of a sample from a chimeric uPA-SCID mouse collected after the administration of stanozolol revealed the presence of 4 additional metabolites. The information obtained from the product ion spectra was used to develop a SRM method for the detection of 19 compounds. This SRM method was applied to several doping positive samples. All the metabolites were detected in both the uPA-SCID mouse sample and positive human samples and were not detected in none of the blank samples tested; confirming the metabolic nature of all the detected compounds. In addition, the application of the SRM method to a single human excretion study revealed that one of the metabolites (4ξ,16ξ-dihydroxy-stanozolol) could be detected in negative ionization mode for a longer period than those commonly used in the screening for stanozolol misuse (3′-hydroxy-stanozolol, 16β-hydroxy-stanozolol and 4β-hydroxy-stanozolol) in doping analysis. The application of the developed approach to several positive doping samples confirmed the usefulness of this metabolite for the screening of stanozolol misuse. Finally, a tentative structure for each detected metabolite has been proposed based on the product ion spectra measured with accurate masses using UPLC–QTOF MS.  相似文献   

7.
The optimal extraction of information from untargeted metabolomics analyses is a continuing challenge. Here, we describe an approach that combines stable isotope labeling, liquid chromatography– mass spectrometry (LC–MS), and a computational pipeline to automatically identify metabolites produced from a selected metabolic precursor. We identified the subset of the soluble metabolome generated from phenylalanine (Phe) in Arabidopsis thaliana, which we refer to as the Phe-derived metabolome (FDM) In addition to identifying Phe-derived metabolites present in a single wild-type reference accession, the FDM was established in nine enzymatic and regulatory mutants in the phenylpropanoid pathway. To identify genes associated with variation in Phe-derived metabolites in Arabidopsis, MS features collected by untargeted metabolite profiling of an Arabidopsis diversity panel were retrospectively annotated to the FDM and natural genetic variants responsible for differences in accumulation of FDM features were identified by genome-wide association. Large differences in Phe-derived metabolite accumulation and presence/absence variation of abundant metabolites were observed in the nine mutants as well as between accessions from the diversity panel. Many Phe-derived metabolites that accumulated in mutants also accumulated in non-Col-0 accessions and was associated to genes with known or suspected functions in the phenylpropanoid pathway as well as genes with no known functions. Overall, we show that cataloguing a biochemical pathway’s products through isotopic labeling across genetic variants can substantially contribute to the identification of metabolites and genes associated with their biosynthesis.

An isotopic labeling and LC–MS pipeline to identify metabolites produced from Phe and its integration with genome-wide association identifies genes associated with the phenylpropanoid pathway.  相似文献   

8.
A rapid, sensitive and specific assay method has been developed to determine plasma concentrations of olopatadine hydrochloride (A) and its metabolites, M1 (B), M2 (C) and M3 (D), using high-performance liquid chromatography with electrospray ionization tandem mass spectrometry (LC–ESI-MS–MS). Olopatadine, its metabolites, and internal standard, KF11796 (E), were separated from plasma using solid-phase extraction (Bond Elut C18 cartridge). The eluate was dried, reconstituted and injected into the LC–ESI-MS–MS system. The calibration curves showed good linearity over the ranges 1–200 ng/ml for olopatadine and M3, and 2–100 ng/ml for M1 and M2, and the method was thoroughly validated and applied to the determination of olopatadine and its metabolites in plasma collected during Phase I clinical trials. Furthermore, the assay values were compared with those determined by the radioimmunoassay method, which has been routinely used to determine olopatadine in plasma.  相似文献   

9.
A fast, robust and sensitive LC–MS–MS method for the determination of zearalenone (ZON) and its metabolites α-zearalenol (α-ZOL) and β-zearalenol (β-ZOL) in beer samples is described. Sample preparation was performed by direct RP-18 solid-phase extraction of undiluted beer samples followed by selective determination of analytes by LC–MS–MS applying an atmospheric pressure chemical ionization (APCI) interface. Using the negative ion mode limits of determination of 0.03–0.06 μg l−1 beer and limits of quantification of 0.07–0.15 μg l−1 beer were achieved, which was distinctly more sensitive than in the positive ion mode. Twenty-three beer samples from different countries, produced from different grains and under different brewing conditions, were investigated by this method, but only in one sample could β-ZOL and ZON be detected. Independently of the type of beer, relative standard deviations between 2.1% and 3.3%, a linear working range of 0.15 μg l−1 to 500 μg l−1 beer and recovery rates around 100% could be achieved when zearalanone (ZAN) was used as internal standard.  相似文献   

10.
Analytical methods for the determination of cloxacillin, ampicillin/hetacillin, and amoxicillin in bovine milk were developed. The methods involved ultrafiltration of milk diluted with methanol, acetonitrile, and water on a 10 000-dalton cut-off filter. Separation of penicillins from other milk components was accomplished by ion-paired chromatography using a microbore column. The penicillins were detected using ultraviolet photodiode array (UV-PDA) detection and confirmed by thermospray liquid chromatography—mass spectrometry (LC—MS). The thermospray spectra of these compounds exhibited [M + H]+ and [M + Na]+ ions along with several fragment ions. The limits of detection for these antibiotics were estimated to be 50 to 100 ppb for LC with UV-PDA detection and 100–200 ppb for thermospray LC—MS detection.  相似文献   

11.
Urinary metabolites of cannabidiol (CBD), a non-psychoactive cannabinoid of potential therapeutic interest, were extracted from dog, rat and human urine, concentrated by chromatography on Sephadex LH-20 and examined by gas chromatography—mass spectrometry as trimethylsilyl (TMS), [2H9]TMS, methyl ester—TMS and methyloxime—TMS derivatives. Fragmentation of the metabolites under electron-impact gave structurally informative fragment ions; computer-generated single-ion plots of these diagnostic ions were used extensively to aid metabolite identification. Over fifty metabolites were identified with considerable species variation. CBD was excreted in substantial concentration in human urine, both in the free state and as its glucuronide. In dog, unusual glucoside conjugates of three metabolites (4″- and 5″-hydroxy- and 6-oxo-CBD), not excreted in the unconjugated state, were found as the major metabolites at early times after drug administration. Other metabolites in all three species were mainly acids. Side-chain hydroxylated derivatives of CBD-7-oic acid were particularly abundant in human urine but much less so in dog. In the latter species the major oxidized metabolites were the products of β-oxidation with further hydroxylation at C-6. A related, but undefined pathway resulted in loss of three carbon atoms from the side-chain of CBD in man with production of 2″-hydroxy-tris,nor-CBD-7-oic acid. Metabolism by the epoxide-diol pathway, resulting in dihydro-diol formation from the Δ-8 double bond, gave metabolites in both dog and human urine. It was concluded that CBD could be used as a probe of the mechanism of several types of biotransformation; particularly those related to carboxylic acid metabolism as intermediates of the type not usually seen with endogenous compounds were excreted in substantial concentration.  相似文献   

12.
Strong anion-exchange (SAX) chromatography and reversed-phase liquid chromatography (RPLC) followed by different mass spectrometric techniques for the separation and identification of conjugated and unconjugated 14C-labelled eltanolone (5β-Pregnan-3α-ol-20-one) metabolites in biological fluids are presented. Conjugates of estradiol were used as model compounds for the development of a SAX based group separation of neutral steroids, glucuronides, sulfates and di-conjugated steroids. The usefulness of the technique is demonstrated by the analysis of 14C-labelled eltanolone metabolites in dog urine. The analytical SAX column used prior to RPLC improved the capacity to separate the metabolites from each other and from endogenous components, compared to a single reversed-phase system. Liquid chromatography negative ion electrospray-mass spectrometry (LC–ESI-MS) was used for the molecular mass determination of conjugated eltanolone metabolites. Unconjugated metabolites and hydrolysed conjugates were identified using gas chromatography–mass spectrometry with an electron impact ion source (GC–MS) after trimethylsilyl (TMS) derivatization. An unexpected finding in dog urine was the diglucuronide formation of eltanolone (presumably after enolisation of its carbonyl group).  相似文献   

13.
Morphine (MOR) is an opioid analgesic used for the treatment of moderate to severe pain. MOR is extensively metabolized to morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G). A rapid and sensitive method that was able to reliably detect at least 0.5 ng/ml of MOR and 1.0 ng/ml of M6G was required to define their pharmacokinetic profiles. An LC–MS–MS method was developed in our laboratory to quantify all three analytes with the required sensitivity and a rapid turnaround time. A solid-phase extraction (SPE) was used to isolate MOR, M3G, M6G, and their corresponding deuterated internal standards from heparinized plasma. The extract was injected on a LC tandem mass spectrometer with a turbo ion-spray interface. Baseline chromatographic separation among MOR, M3G, and M6G peaks was achieved on a silica column with an aqueous organic mobile phase consisting of formic acid, water, and acetonitrile. The total chromatographic run time was 3 min per injection, with retention times of 1.5, 1.9 and 2.4 min for MOR, M6G, and M3G, respectively. Chromatographic separation of M3G and M6G from MOR was paramount in establishing the LC–MS–MS method selectivity because of fragmentation of M3G and M6G to MOR at the LC–MS interface. The standard curve range in plasma was 0.5–50 ng/ml for MOR, 1.0–100 ng/ml for M6G, and 10–1000 ng/ml for M3G. The inter-day precision and accuracy of the quality control (QC) samples were <7% relative standard deviation (RSD) and <6% relative error (R.E.) for MOR, <9% RSD and <5% R.E. for M6G, and <3% RSD and <6% R.E. for M3G. Analyte stability during sample processing and storage were established. Method ruggedness was demonstrated by the reproducible performance from multiple analysts using several LC–MS–MS systems to analyze over one thousand samples from clinical trials.  相似文献   

14.
A rapid, simple, and sensitive liquid chromatography–atmospheric pressure chemical ionization tandem mass spectrometry (LC–APCI-MS/MS) method was developed for the identification and quantification of emodin metabolites in Raji cells, using aloe-emodin as an internal standard. Analyses were performed on an LC system employing a Cosmosil 5C18 AR-II column and a stepwise gradient elution with methanol–20 mM ammonium formate at a flow rate of 1.0 mL/min operating in the negative ion mode. As a result, the starting material emodin and its five metabolites were detected by analyzing extracts of Raji cells that had been cultivated in the presence of emodin. The identification of the metabolites and elucidation of their structures were performed by comparing their retention times and spectral patterns with those of synthetic samples. In addition to the major metabolite 8-O-methylemodin, four other metabolites were assigned as ω-hydroxyemodin, 3-O-methyl-ω-hydroxyemodin, 3-O-methylemodin (physcion), and chrysophanol.  相似文献   

15.
A gas chromatographic—mass spectrometric (GC—MS) method is described which quantitates 5-fluorouracil (5-FU) plasma levels ranging from 0.5 to 50 ng/ml. The analysis uses two internal standards, 1,3-[15N2]-5-fluorouracil and 5-chlorouracil. Extraction and derivatization of the pyrimidine bases were accomplished in a single step using acetonitrile. Compounds were analyzed as their 1,3-dipentafluorobenzyl derivatives by electron-impact MS, and the GC—MS analysis was automated with respect to sample injection and data reduction. Stability of the analysis was demonstrated by continuous unattended analysis of 5-FU in human plasma for periods of up to three days with no deterioration of the quantitative results. The method is applicable to quantitating 5-FU plasma levels in patients receiving protracted infusions of the drug for colorectal cancer or other malignancies.  相似文献   

16.
A convenient procedure for determination of seven betaine analogs and dimethylsulfoniopropionate (DMSP) in extracts of coral tissues using LC–MS stable isotope dilution is described. Extraction procedures were optimized for selective extraction of polar metabolites from coral tissues. The LC–MS protocol employed a pentafluorophenylpropyl (PFPP) column for HPLC separation, with chromatographic resolution of isobaric and isomeric zwitterionic metabolites optimized by adjusting the acidity of the mobile phase. A ternary gradient was used to exploit the unusual retention characteristics of cationic metabolites on the PFPP column, with incorporation of ammonium acetate in a later gradient stage promoting elution of more hydrophobic betaines which are retained at high organic content in the absence of ammonium acetate. We demonstrate that the new LC–MS based method provides accurate measurements from nanomolar to high micromolar concentrations, and can be applied for profiling of betaine metabolites and DMSP in corals or other aquatic organisms.  相似文献   

17.
A sensitive, simple and fast liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 1-(4-chlorophenyl)biguanide (4CPB), was developed and validated over a concentration range of 1-2000 ng/mL using only 50 microL of blood or plasma. After a simple solvent precipitation procedure, the supernatant was analysed directly by HPLC-MS/MS. Separation was achieved using an ethyl-linked phenyl reverse phase column with polar endcapping with an acetonitrile-water-formic acid gradient. Mass spectrometry was performed using a triple quadrupole mass spectrometer operating in positive electrospray ionization mode. The elution of PG (254.07-->169.99), CG (252.12-->195.02) and 4CPB (212.06-->153.06) was monitored using selected reaction monitoring. The three compounds and the internal standard (chloroproguanil) were well separated by HPLC and no interfering peaks were detected at the usual concentrations found in blood and plasma. The limit of quantification of PG and CG was 1 ng/mL and 5 ng/mL for 4CPB in rat blood and plasma. The extraction efficiency of PG, CG and 4CPB from rat blood and plasma was higher than 73%. The intra- and inter-assay variability of PG, CG and 4CPB were within 12% and the accuracy within +/-5%. This new assay offers higher sensitivity and a much shorter run time over earlier methods.  相似文献   

18.
The dioxopiperazine metabolites of quinapril in plasma and urine were extracted with hexane—dichloroethane (1:1) under acidic conditions. Following derivatization with pentafluorobenzyl bromide and purification of the desired reaction products using a column packed with silica gel, the metabolites were analysed separately by capillary column gas chromatography—electron-impact mass spectrometry with selected-ion monitoring. The limits of quantitation for the metabolites were 0.2 ng/ml in plasma and 1 ng/ml in urine. The limits of detection were 0.1 ng/ml in plasma and 0.5 ng/ml in urine, at a signal-to-noise ratio of > 3 and > 5, respectively. The proposed method is applicable to pharmacokinetic studies.  相似文献   

19.
A solid-phase extract from Protoceratium reticulatum was partitioned between water and butanol and the two fractions purified on an alumina column. Fractionation was monitored by ELISA and LC–MS. Results indicate that while almost all yessotoxin (1) was extracted into butanol, large amounts of yessotoxin analogs remained in the aqueous extract along with lesser amounts in the butanolic extract. NMR analysis of selected fractions from reverse-phase chromatography of the extracts confirmed the presence of yessotoxin analogs, although structure determinations were not possible due to the complexity of the mixtures. Analysis of fractions with LC–MS3 and neutral-loss LC–MS/MS indicated the presence of more than 90 yessotoxin analogs, although structures for most of these have not yet been determined. These analogs provide a mechanism to rationalise the discrepancy between ELISA and LC–MS analyses of algae and shellfish.  相似文献   

20.
A new simple and sensitive assay has been developed for the quantitative measurement of BN50730 at the picomole level in human plasma and urine. The drug and the internal standard (BN50765) were measured by combined liquid chromatography—negative chemical ionization mass spectrometry with methane as the reagent gas. A simple solid—liquid extraction procedure was used to isolate BN50730 from complex biological matrices. Mild operating conditions were required to assay the parent drug with a particle beam interface from Hewlett-Packard. The mass spectrometer was tuned to monitor the intense ion m/z 333, which was generated in the ion source by a dissociative capture process. This assay was performed with 1 ml of plasma or 0.1 ml of urine, and the quantification limit of the method was statistically calculated as 1 ng ml−1. The very low relative standard deviation and mean percentage of error calculated during the different within-day or between-day repeatability assays clearly demonstrate the ruggedness of the technique for the routine determination of BN50730 in the biological fluids. Some preliminary results on the pharmacokinetics of the drug are presented to illustrate the applicability of this new powerful LC—MS method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号