首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 630 毫秒
1.

Introduction

Prosthetic mesh infection constitutes one of the major complications following hernia repair. Antimicrobial, non-antibiotic biomaterials have the potential to reduce bacterial adhesion to the mesh surface and adjacent tissues while avoiding the development of novel antibiotic resistance. This study assesses the efficacy of presoaking reticular polypropylene meshes in chlorhexidine or a chlorhexidine and allicin combination (a natural antibacterial agent) for preventing bacterial infection in a short-time hernia-repair rabbit model.

Methods

Partial hernia defects (5 x 2 cm) were created on the lateral right side of the abdominal wall of New Zealand White rabbits (n = 21). The defects were inoculated with 0.5 mL of a 106 CFU/mL Staphylococcus aureus ATCC25923 strain and repaired with a DualMesh Plus antimicrobial mesh or a Surgipro mesh presoaked in either chlorhexidine (0.05%) or allicin-chlorhexidine (900 μg/mL-0.05%). Fourteen days post-implant, mesh contraction was measured and tissue specimens were harvested to evaluate bacterial adhesion to the implant surface (via sonication, S. aureus immunolabeling), host-tissue incorporation (via staining, scanning electron microscopy) and macrophage response (via RAM-11 immunolabeling).

Results

The polypropylene mesh showed improved tissue integration relative to the DualMesh Plus. Both the DualMesh Plus and the chlorhexidine-soaked polypropylene meshes exhibited high bacterial clearance, with the latter material showing lower bacterial yields. The implants from the allicin-chlorhexidine group displayed a neoformed tissue containing differently sized abscesses and living bacteria, as well as a diminished macrophage response. The allicin-chlorhexidine coated implants exhibited the highest contraction.

Conclusions

The presoaking of reticular polypropylene materials with a low concentration of chlorhexidine provides the mesh with antibacterial activity without disrupting tissue integration. Due to the similarities found with the antimicrobial DualMesh Plus material, the chlorhexidine concentration tested could be utilized as a prophylactic treatment to resist infection by prosthetic mesh during hernia repair.  相似文献   

2.

Purpose

To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM) images using Photoshop software and to assess its intraobserver and interobserver reproducibility.

Methods

Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA), posterior chamber area (PCA), iris cross-section area (ICA) and angle recess area (ARA) were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV), and intraclass correlation coefficient (ICC).

Results

All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (p<0.001).

Conclusion

Measurements of ocular anterior segment areas on UBM images by Photoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.  相似文献   

3.

Background

Vascular risk factors may be associated with disability independently of vascular events. We examined whether the American Heart Association’s 7 ideal cardiovascular health (CVH) metrics were independently associated with disability in a nationally representative cohort.

Methods

Adults age ≥20 years from the National Health and Nutrition Examination Survey 2005–2012 were included. Ideal CVH was calculated as a composite of 7 measures, each scored 0–2. Primary predictors were number of ideal CVH metrics and score of CVH metrics. The outcome was a dichotomous score from 20 activities of daily living (ADL) and instrumental ADLs. Unadjusted and adjusted weighted logistic models estimated associations between ideal CVH and disability. The data were analyzed in 2015.

Results

Among 22692 participants, mean age was 46.9 years. Cardiac disease and stroke were present in 6.6% and 2.8%; 90.3% had poor physical activity and 89.9% poor diet. Among 3975 individuals with full CVH data, in fully adjusted models, OR for disability was 0.90 (95% CI 0.83–0.98) per point increase in ideal CVH score, and 0.84 (0.73–0.97) per additional number of ideal CVH metrics.

Conclusions

CVH metrics were strongly and significantly associated with reduced odds of disability independently of vascular and non-vascular conditions. Poorer CVH may cause subclinical vascular disease resulting in disability.  相似文献   

4.

Objectives

Respiration-induced motion in the liver causes potential errors on the measurement of contrast medium in abdominal artery from multiphase hepatic CT scans. In this study, we investigated the use of hepatic CT images to quantitatively estimate the abdominal artery motion due to respiration by optical flow method.

Materials and Methods

A total of 132 consecutive patients were included in our patient cohort. We apply the optical flow method to compute the motion of the abdominal artery due to respiration.

Results

The minimum and maximum displacements of the abdominal artery motion were 0.02 and 30.87 mm by manual delineation, 0.03 and 40.75 mm calculated by optical flow method, respectively. Both high consistency and correlation between the present method and the physicians’ manual delineations were acquired with the regression equation of movement, y = 0.81x+0.25, r = 0.95, p<0.001.

Conclusion

We estimated the motion of abdominal artery due to respiration using the optical flow method in multiphase hepatic CT scans and the motion estimations were validated with the visualization of physicians. The quantitative analysis of respiration-related movement of abdominal artery could be used for motion correction in the measurement of contrast medium passing though abdominal artery in multiphase CT liver scans.  相似文献   

5.

Introduction

Presoaking meshes for hernia repair with antiseptics prior to implantation could decrease the adhesion of microorganisms to the material surface and reduce the risk of antibiotic resistances. In this work, we evaluate chlorhexidine and allicin (natural antiseptic not yet tested for these purposes) against vancomycin as antiseptics to be used in the pretreatment of a heavyweight polypropylene mesh using an in vitro model of bacterial contamination.

Methods

Solutions of saline, vancomycin (40 µg/mL), allicin (1,000 µg/mL), chlorhexidine (2%-0.05%) and the combination allicin-chlorhexidine (900 µg/mL-0.05%) were analyzed with agar diffusion tests in the presence of 106 CFU Staphylococcus aureus ATCC25923. Additionally, sterile fragments of Surgipro (1 cm2) were soaked with the solutions and cultured onto contaminated agar plates for 24/48/72 h. The antimicrobial material DualMesh Plus was utilized as positive control. At every time, the inhibition zones were measured and the bacterial adhesion to the mesh surface quantified (sonication, scanning electron microscopy). Cytotoxicity of the treatments was examined (alamarBlue) using rabbit skin fibroblasts.

Results

The largest zones of inhibition were created by allicin-chlorhexidine. Chlorhexidine was more effective than vancomycin, and allicin lost its effectiveness after 24 h. No bacteria adhered to the surface of the DualMesh Plus or the meshes soaked with vancomycin, chlorhexidine and allicin-chlorhexidine. On the contrary, saline and allicin allowed adherence of high loads of bacteria. Vancomycin had no toxic effects on fibroblasts, while allicin and chlorhexidine exerted high toxicity. Cytotoxicity was significantly reduced with the allicin-chlorhexidine combination.

Conclusions

The use of antiseptics such as chlorhexidine, alone or combined with others like allicin, could represent an adequate prophylactic strategy to be used for hernia repair materials because soaking with these agents provides the mesh with similar antibacterial properties to those observed after soaking with vancomycin, similar to the effect of DualMesh Plus.  相似文献   

6.

Background

The role of the sino-nasal microbiome in CRS remains unclear. We hypothesized that the bacteria within mucosal-associated biofilms may be different from the more superficial-lying, free-floating bacteria in the sinuses and that this may impact on the microbiome results obtained. This study investigates whether there is a significant difference in the microbiota of a sinonasal mucosal tissue sample versus a swab sample.

Methods

Cross-sectional study with paired design. Mucosal biopsy and swab samples were obtained intra-operatively from the ethmoid sinuses of 6 patients with CRS. Extracted DNA was sequenced on a Roche-454 sequencer using 16S-rRNA gene targeted primers. Data were analyzed using QIIME 1.8 software package.

Results

At a maximum subsampling depth of 1,100 reads, the mean observed species richness was 33.3 species (30.6 for swab, versus 36 for mucosa; p > 0.05). There was no significant difference in phylogenetic and non-phylogenetic alpha diversity metrics (Faith’s PD_Whole_Tree and Shannon’s index) between the two sampling methods (p > 0.05). The type of sample also had no significant effect on phylogenetic and non-phylogenetic beta diversity metrics (Unifrac and Bray-Curtis; p > 0.05).

Conclusion

We observed no significant difference between the microbiota of mucosal tissue and swab samples. This suggests that less invasive swab samples are representative of the sinonasal mucosa microbiome and can be used for future sinonasal microbiome studies.  相似文献   

7.

Overview

Eight years of octopus fishery records from southwest Madagascar reveal significant positive impacts from 36 periodic closures on: (a) fishery catches and (b) village fishery income, such that (c) economic benefits from increased landings outweigh costs of foregone catch. Closures covered ~20% of a village’s fished area and lasted 2-7 months.

Fishery Catches from Each Closed Site

Octopus landings and catch per unit effort (CPUE) significantly increased in the 30 days following a closure’s reopening, relative to the 30 days before a closure (landings: +718%, p<0.0001; CPUE: +87%, p<0.0001; n = 36). Open-access control sites showed no before/after change when they occurred independently of other management (“no ban”, n = 17/36). On the other hand, open-access control sites showed modest catch increases when they extended a 6-week seasonal fishery shutdown (“ban”, n = 19/36). The seasonal fishery shutdown affects the entire region, so confound all potential control sites.

Fishery Income in Implementing Villages

In villages implementing a closure, octopus fishery income doubled in the 30 days after a closure, relative to 30 days before (+132%, p<0.001, n = 28). Control villages not implementing a closure showed no increase in income after “no ban” closures and modest increases after “ban” closures. Villages did not show a significant decline in income during closure events.

Net Economic Benefits from Each Closed Site

Landings in closure sites generated more revenue than simulated landings assuming continued open-access fishing at that site (27/36 show positive net earnings; mean +$305/closure; mean +57.7% monthly). Benefits accrued faster than local fishers’ time preferences during 17-27 of the 36 closures. High reported rates of illegal fishing during closures correlated with poor economic performance.

Broader Co-Management

We discuss the implications of our findings for broader co-management arrangements, particularly for catalyzing more comprehensive management.  相似文献   

8.

Introduction

Pectopexy, a laparoscopic method for prolapse surgery, showed promising results in recent literature. Further improving this approach by reducing surgical time may decrease complication rates and patient morbidity. Since laparoscopic suturing is a time consuming task, we propose a single suture /mesh ileo-pectineal ligament fixation as opposed to the commonly used continues approach.

Methods

Evaluation was performed on human non-embalmed, fresh cadaver pelves. A total of 33 trials was performed. Eight female pelves with an average age of 75, were used. This resulted in 16 available ligaments. Recorded parameters were ultimate load, displacement at failure and stiffness.

Results

The ultimate load for the mesh + simplified single “interrupted” suture (MIS) group was 35 (± 12) N and 48 (± 7) N for the mesh + continuous suture (MCS) group. There was no significant difference in the ultimate load between both groups (p> 0.05). This was also true for displacement at failure measured at 37 (± 12) mm and 36 (±5) mm respectively. There was also no significant difference in stiffness and failure modes.

Conclusion

Given the data above we must conclude that a continuous suture is not necessary in laparoscopic mesh / ileo-pectineal ligament fixation during pectopexy. Ultimate load and displacement at failure results clearly indicate that a single suture is not inferior to a continuous approach. The use of two single sutures may improve ligamental fixation. However, overall stability should not benefit since the surgical mesh remains the limiting factor.  相似文献   

9.

Objective

To quantitatively evaluate the anterior segment using anterior segment optical coherence tomography (AS-OCT) following Boston keratoprosthesis type 1.

Methods

A retrospective study consisted of AS-OCT imaging at a single time point postoperatively in 52 eyes. Main outcomes measures include anatomical and functional anterior chamber depth (ACD), angle (ACA) and peripheral and proximal synechiae.

Results

The mean time point of imaging was 19.3 months postoperatively. Average anatomical and functional ACD was 2.0 and 0.21 mm respectively, and mean ACA ranged from 2.5° to 6.14° in representative meridians. An average of 8.7 clock hours of angle closure was observed in the 25 eyes in which all meridians were imaged. The majority of eyes showed peripheral (86.5%) and proximal (67.3%) synechiae.

Conclusions

AS-OCT is a useful tool for quantitative evaluation of anterior segment and angle after keratoprosthesis, which is otherwise poorly visible. The majority of eyes showed shallow ACD, extensive angle closure and synechiae formation.  相似文献   

10.

Purpose

To assess the measurement variability of subsolid nodules (SSNs) in follow-up situations and to compare the degree of variability between measurement metrics.

Methods

Two same-day repeat-CT scans of 69 patients (24 men and 45 women) with 69 SSNs were randomly assigned as initial or follow-up scans and were read by the same (situation 1) or different readers (situation 2). SSN size and solid portion size were measured in both situations. Measurement variability was calculated and coefficients of variation were used for comparisons.

Results

Measurement variability for the longest and average diameter of SSNs was ±1.3 mm (±13.0%) and ±1.3 mm (±14.4%) in situation 1, and ±2.2 mm (±21.0%) and ±2.1 mm (±21.3%) in situation 2, respectively. For solid portion, measurement variability on lung and mediastinal windows was ±1.2 mm (±27.1%) and ±0.8 mm (±24.0%) in situation 1, and ±3.7 mm (±61.0%) and ±1.5 mm (±47.3%) in situation 2, respectively. There were no significant differences in the degree of variability between the longest and average diameters and between the lung and mediastinal window settings (p>0.05). However, measurement variability significantly increased when the follow-up and initial CT readers were different (p<0.001).

Conclusions

A cutoff of ±2.2 mm can be reliably used to determine true nodule growth on follow-up CT. Solid portion measurements were not reliable in evaluating SSNs’ change when readers of initial and follow-up CT were different.  相似文献   

11.

Background

Hernia repair is the most common surgical procedure in the world. Augmentation with synthetic meshes has gained importance in recent decades. Most of the published work about hernia meshes focuses on the surgical technique, outcome in terms of mortality and morbidity and the recurrence rate. Appropriate biomechanical and engineering terminology is frequently absent. Meshes are under continuous development but there is little knowledge in the public domain about their mechanical properties. In the presented experimental study we investigated the mechanical properties of several widely available meshes according to German Industrial Standards (DIN ISO).

Methodology/Principal Findings

Six different meshes were assessed considering longitudinal and transverse direction in a uni-axial tensile test. Based on the force/displacement curve, the maximum force, breaking strain, and stiffness were computed. According to the maximum force the values were assigned to the groups weak and strong to determine a base for comparison. We discovered differences in the maximum force (11.1±6.4 to 100.9±9.4 N/cm), stiffness (0.3±0.1 to 4.6±0.5 N/mm), and breaking strain (150±6% to 340±20%) considering the direction of tension.

Conclusions/Significance

The measured stiffness and breaking strength vary widely among available mesh materials for hernia repair, and most of the materials show significant anisotropy in their mechanical behavior. Considering the forces present in the abdominal wall, our results suggest that some meshes should be implanted in an appropriate orientation, and that information regarding the directionality of their mechanical properties should be provided by the manufacturers.  相似文献   

12.

Purpose

A novel phantom for image quality testing for functional magnetic resonance imaging (fMRI) scans is described.

Methods

The cylindrical, rotatable, ~4.5L phantom, with eight wedge-shaped compartments, is used to simulate rest and activated states. The compartments contain NiCl2 doped agar gel with alternating concentrations of agar (1.4%, 1.6%) to produce T1 and T2 values approximating brain grey matter. The Jacard index was used to compare the image distortions for echo planar imaging (EPI) and gradient recalled echo (GRE) scans. Contrast to noise ratio (CNR) was compared across the imaging volume for GRE and EPI.

Results

The mean T2 for the two agar concentrations were found to be 106.5±4.8, 94.5±4.7 ms, and T1 of 1500±40 and 1485±30 ms, respectively. The Jacard index for GRE was generally found to be higher than for EPI (0.95 versus 0.8). The CNR varied from 20 to 50 across the slices and echo times used for EPI scans, and from 20 to 40 across the slices for the GRE scans. The phantom provided a reproducible CNR over 25 days.

Conclusions

The phantom provides a quantifiable signal change over a head-size imaging volume with EPI and GRE sequences, which was used for image quality assessment.  相似文献   

13.

Introduction

The capability of CT perfusion (CTP) Alberta Stroke Program Early CT Score (ASPECTS) to predict outcome and identify ischemia severity in acute ischemic stroke (AIS) patients is still questioned.

Methods

62 patients with AIS were imaged within 8 hours of symptom onset by non-contrast CT, CT angiography and CTP scans at admission and 24 hours. CTP ASPECTS was calculated on the affected hemisphere using cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) maps by subtracting 1 point for any abnormalities visually detected or measured within multiple cortical circular regions of interest according to previously established thresholds. MTT-CBV ASPECTS was considered as CTP ASPECTS mismatch. Hemorrhagic transformation (HT), recanalization status and reperfusion grade at 24 hours, final infarct volume at 7 days and modified Rankin scale (mRS) at 3 months after onset were recorded.

Results

Semi-quantitative and quantitative CTP ASPECTS were highly correlated (p<0.00001). CBF, CBV and MTT ASPECTS were higher in patients with no HT and mRS≤2 and inversely associated with final infarct volume and mRS (p values: from p<0.05 to p<0.00001). CTP ASPECTS mismatch was slightly associated with radiological and clinical outcomes (p values: from p<0.05 to p<0.02) only if evaluated quantitatively. A CBV ASPECTS of 9 was the optimal semi-quantitative value for predicting outcome.

Conclusions

Our findings suggest that visual inspection of CTP ASPECTS recognizes infarct and ischemic absolute values. Semi-quantitative CBV ASPECTS, but not CTP ASPECTS mismatch, represents a strong prognostic indicator, implying that core extent is the main determinant of outcome, irrespective of penumbra size.  相似文献   

14.
15.

Objective

To identify early changes in brain structure and function that are associated with cardiovascular risk factors (CVRF).

Design

Cross-sectional brain Magnetic Resonance I (MRI) study.

Setting

Community based cohort in three U.S. sites.

Participants

A Caucasian and African-American sub-sample (n= 680; mean age 50.3 yrs) attending the 25 year follow-up exam of the Coronary Artery Risk Development in Young Adults Study.

Primary and Secondary Outcomes

3T brain MR images processed for quantitative estimates of: total brain (TBV) and abnormal white matter (AWM) volume; white matter fractional anisotropy (WM-FA); and gray matter cerebral blood flow (GM-CBF). Total intracranial volume is TBV plus cerebral spinal fluid (TICV). A Global Cognitive Function (GCF) score was derived from tests of speed, memory and executive function.

Results

Adjusting for TICV and demographic factors, current smoking was significantly associated with lower GM-CBF and TBV, and more AWM (all <0.05); SA with lower GM-CBF, WM-FA and TBV (p=0.01); increasing BMI with decreasing GM-CBF (p<0003); hypertension with lower GM-CBF, WM-FA, and TBV and higher AWM (all <0.05); and diabetes with lower TBV (p=0.007). The GCS was lower as TBV decreased, AWM increased, and WM-FA (all p<0.01).

Conclusion

In middle age adults, CVRF are associated with brain health, reflected in MRI measures of structure and perfusion, and cognitive functioning. These findings suggest markers of mid-life cardiovascular and brain health should be considered as indication for early intervention and future risk of late-life cerebrovascular disease and dementia.  相似文献   

16.

Background

Understanding the three-dimensional (3-D) micro-architecture of lung tissue can provide insights into the pathology of lung disease. Micro computed tomography (µCT) has previously been used to elucidate lung 3D histology and morphometry in fixed samples that have been stained with contrast agents or air inflated and dried. However, non-destructive microstructural 3D imaging of formalin-fixed paraffin embedded (FFPE) tissues would facilitate retrospective analysis of extensive tissue archives of lung FFPE lung samples with linked clinical data.

Methods

FFPE human lung tissue samples (n = 4) were scanned using a Nikon metrology µCT scanner. Semi-automatic techniques were used to segment the 3D structure of airways and blood vessels. Airspace size (mean linear intercept, Lm) was measured on µCT images and on matched histological sections from the same FFPE samples imaged by light microscopy to validate µCT imaging.

Results

The µCT imaging protocol provided contrast between tissue and paraffin in FFPE samples (15mm x 7mm). Resolution (voxel size 6.7 µm) in the reconstructed images was sufficient for semi-automatic image segmentation of airways and blood vessels as well as quantitative airspace analysis. The scans were also used to scout for regions of interest, enabling time-efficient preparation of conventional histological sections. The Lm measurements from µCT images were not significantly different to those from matched histological sections.

Conclusion

We demonstrated how non-destructive imaging of routinely prepared FFPE samples by laboratory µCT can be used to visualize and assess the 3D morphology of the lung including by morphometric analysis.  相似文献   

17.

Background & Objectives

Cross-sectional magnetic resonance imaging (MRI) suggests that Parkinson’s disease (PD) is associated with changes in cerebral tissue volume, diffusion tensor imaging metrics, and perfusion values. Here, we performed a longitudinal multimodal MRI study—including structural, diffusion tensor imaging (DTI), and perfusion MRI—to investigate progressive brain changes over one year in a group of older PD patients at a moderate stage of disease.

Methods

Twenty-three non-demented PD (mean age (SD) = 69.5 (6.4) years, disease duration (SD) = 5.6 (4.3) years) and 23 matched control participants (mean age: 70.6 (6.8)) completed extensive neuropsychological and clinical assessment, and multimodal 3T MRI scanning at baseline and one year later. We used a voxel-based approach to assess change over time and group-by-time interactions for cerebral structural and perfusion metrics.

Results

Compared to controls, in PD participants there was localized grey matter atrophy over time in bilateral inferior and right middle temporal, and left orbito-frontal cortices. Using a voxel-based approach that focused on the centers of principal white matter tracts, the PD and control cohorts exhibited similar levels of change in DTI metrics. There was no significant change in perfusion, cognitive, or motor severity measures.

Conclusions

In a cohort of older, non-demented PD participants, macrostructural MRI detected atrophy in the PD group compared with the control group in temporal and orbito-frontal cortices. Changes in diffusion MRI along principal white matter tracts over one year were found, but this was not differentially affected by PD.  相似文献   

18.

Objective

To characterize parasomnia behaviors on arousal from NREM sleep in Parkinson’s Disease (PD) and Multiple System Atrophy (MSA).

Methods

From 30 patients with PD, Dementia with Lewy Bodies/Dementia associated with PD, or MSA undergoing nocturnal video-polysomnography for presumed dream enactment behavior, we were able to select 2 PD and 2 MSA patients featuring NREM Parasomnia Behviors (NPBs). We identified episodes during which the subjects seemed to enact dreams or presumed dream-like mentation (NPB arousals) versus episodes with physiological movements (no-NPB arousals). A time-frequency analysis (Morlet Wavelet Transform) of the scalp EEG signals around each NPB and no- NPB arousal onset was performed, and the amplitudes of the spectral frequencies were compared between NPB and no-NPB arousals.

Results

19 NPBs were identified, 12 of which consisting of ‘elementary’ NPBs while 7 resembling confusional arousals. With quantitative EEG analysis, we found an amplitude reduction in the 5-6 Hz band 40 seconds before NPBs arousal as compared to no-NPB arousals at F4 and C4 derivations (p<0.01).

Conclusions

Many PD and MSA patients feature various NREM sleep-related behaviors, with clinical and electrophysiological differences and similarities with arousal parasomnias in the general population.

Significance

This study help bring to attention an overlooked phenomenon in neurodegenerative diseases.  相似文献   

19.

Purpose

This study aimed to calculate the flexion-extension axis (FEA) of the knee through in-vivo knee kinematics data, and then compare it with two major anatomical axes of the femoral condyles: the transepicondylar axis (TEA) defined by connecting the medial sulcus and lateral prominence, and the cylinder axis (CA) defined by connecting the centers of posterior condyles.

Methods

The knee kinematics data of 20 healthy subjects were acquired under weight-bearing condition using bi-planar x-ray imaging and 3D-2D registration techniques. By tracking the vertical coordinate change of all points on the surface of femur during knee flexion, the FEA was determined as the line connecting the points with the least vertical shift in the medial and lateral condyles respectively. Angular deviation and distance among the TEA, CA and FEA were measured.

Results

The TEA-FEA angular deviation was significantly larger than that of the CA-FEA in 3D and transverse plane (3.45° vs. 1.98°, p < 0.001; 2.72° vs. 1.19°, p = 0.002), but not in the coronal plane (1.61° vs. 0.83°, p = 0.076). The TEA-FEA distance was significantly greater than that of the CA-FEA in the medial side (6.7 mm vs. 1.9 mm, p < 0.001), but not in the lateral side (3.2 mm vs. 2.0 mm, p = 0.16).

Conclusion

The CA is closer to the FEA compared with the TEA; it can better serve as an anatomical surrogate for the functional knee axis.  相似文献   

20.

Purpose

To evaluate the ability of longitudinal Useful Field of View (UFOV) and simulated driving measurements to predict future occurrence of motor vehicle collision (MVC) in drivers with glaucoma.

Design

Prospective observational cohort study.

Participants

117 drivers with glaucoma followed for an average of 2.1 ± 0.5 years.

Methods

All subjects had standard automated perimetry (SAP), UFOV, driving simulator, and cognitive assessment obtained at baseline and every 6 months during follow-up. The driving simulator evaluated reaction times to high and low contrast peripheral divided attention stimuli presented while negotiating a winding country road, with central driving task performance assessed as “curve coherence”. Drivers with MVC during follow-up were identified from Department of Motor Vehicle records.

Main Outcome Measures

Survival models were used to evaluate the ability of driving simulator and UFOV to predict MVC over time, adjusting for potential confounding factors.

Results

Mean age at baseline was 64.5 ± 12.6 years. 11 of 117 (9.4%) drivers had a MVC during follow-up. In the multivariable models, low contrast reaction time was significantly predictive of MVC, with a hazard ratio (HR) of 2.19 per 1 SD slower reaction time (95% CI, 1.30 to 3.69; P = 0.003). UFOV divided attention was also significantly predictive of MVC with a HR of 1.98 per 1 SD worse (95% CI, 1.10 to 3.57; P = 0.022). Global SAP visual field indices in the better or worse eye were not predictive of MVC. The longitudinal model including driving simulator performance was a better predictor of MVC compared to UFOV (R2 = 0.41 vs R2 = 0.18).

Conclusions

Longitudinal divided attention metrics on the UFOV test and during simulated driving were significantly predictive of risk of MVC in glaucoma patients. These findings may help improve the understanding of factors associated with driving impairment related to glaucoma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号