首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A recombinant pore-forming peptide of Clonorchis sinensis, clonorin, was evaluated for serodiagnostic reagent of clonorchiasis by enzyme-linked immunosorbent assay detecting IgG antibody. Recombinant clonorin showed 100% specificity and low sensitivity for sera of human clonorchiasis. In contrast, C. sinensis crude antigen revealed lower specificity and higher sensitivity than recombinant clonorin did. In sera of experimental rabbits, clonorin-specific IgG antibody was increased remarkably 8 weeks after the infection and retained around level of OD(490)=0.2 for 1 year. With excellent antigenic specificity, it is suggested that the recombinant clonorin can be used as an ingredient of the cocktail antigen for serodiagnosis of clonorchiasis from early stages of the infection.  相似文献   

2.
Antibodies specific for Echinococcus granulosus were affinity purified from dog serum on transfer blots containing putative serodiagnostic antigens. These antibodies and serum pools derived from dogs with E. granulosus infections were used to screen a lambda gt11 cDNA library constructed using E. granulosus protoscolex mRNA. Nine definitive antigenic clones were isolated and characterized, of which one (c10P1) gave strong specific reactions in plaque immunoassay with sera from E. granulosus infected dogs. These clones were all subcloned into the plasmid vector pGEX-1. Antigenicity of clones was confirmed in colony immunoassay and/or immunoblot. Glutathione S-transferase (GST) fusion proteins of individual subclones were produced in Escherichia coli, purified by affinity chromatography and evaluated in ELISA using sera from dogs with infections of E. granulosus, Taenia spp. or nematodes, and helminth-free dog sera. The GST fusion protein 10P1 showed a specificity of 100% in ELISA for diagnosis of E. granulosus infection in dogs despite its relatively low sensitivity. Further investigations aim to identify additional recombinant antigens and test 10P1 expressed in alternative expression systems to increase diagnostic sensitivity of the ELISA.  相似文献   

3.
A mu-class glutathione S-transferase (Cs26GST) of molecular mass 26 kDa was characterized from Clonorchis sinensis. In adult C. sinensis, the distribution of the Cs26GST was investigated by immuno-histochemistry and electron microscopy. Cs26GST was localized to the tegument and parenchyma. Immunogold labeling was strong in the tegumental cell bodies and moderate in the tegument and ova in the oviduct. It is suggested that Cs26GST plays a role in the metabolism and fecundity of C. sinensis.  相似文献   

4.
The objective of this study was expression of a recombinant fusion protein p24-gp41 to gain a proper folding pattern of the proteins which could be recognized by specific antibodies against human immunodeficiency virus type 1 (HIV-1) for development of a reliable serodiagnostic kit. Serodiagnostic method using enzyme-linked immunosorbent assay (ELISA) with the expressed recombinant fusion protein p24-gp41 was carried out to test the sensitivity and specificity of the protein using human sera and various reference panels from Boston Biomedica Inc. (BBI). The level of the expression was determined to be 30% and the final recovery from fermentation and purification process was calculated as 80 mg/L with more than 98% purity. The developed ELISA assay was demonstrated to have 100 and 99.5% sensitivity and specificity, respectively, detecting anti-HIV-1 antibody using 900 positive and 10,000 negative human sera. The developed assay showed reliable results in comparison with other reference HIV ELISA kits using various BBI panels as well. In conclusion, the recombinant fusion protein p24-gp41 was expressed and used to develop a serodiagnostic kit for screening of the HIV-1 with high sensitivity (100%) and specificity (99.5%) which could be useful for screening large groups of blood donors.  相似文献   

5.
Clonorchiasis caused by Clonorchis sinensis is endemic in East Asia; approximately 15 million people have been infected thus far. To diagnose the infection, serodiagnostic tests with excellent functionality should be performed. First, 607 expressed sequence tags encoding polypeptides with a secretory signal were expressed into recombinant proteins using an in vitro translation system. By protein array-based screening using C. sinensis-infected sera, 18 antigen candidate proteins were selected and assayed for cross-reactivity against Opisthorchis viverrini-infected sera. Of the six antigenic proteins selected, four were synthesized on large scale in vitro and evaluated for antigenicity against the flukes-infected human sera using ELISA. CsAg17 antigen showed the highest sensitivity (77.1%) and specificity (71.2%). The sensitivity and specificity of the bacterially produced CsAg17-28GST fusion antigen was similar to those of CsAg17 antigen. CsAg17 antigen can be used to develop point-of-care serodiagnostic tests for clonorchiasis.  相似文献   

6.
Crimean-Congo Hemorrhagic Fever Virus (CCHFV) is a geographically widespread tick-borne arbovirus that has been recognized by the WHO as an emerging pathogen needing urgent attention to ensure preparedness for potential outbreaks. Therefore, availability of accurate diagnostic tools for identification of acute cases is necessary.A panel comprising 121 sequential serum samples collected during acute, convalescent and subsided phase of PCR-proven CCHFV infection from 16 Kosovar patients was used to assess sensitivity. Serum samples from 60 healthy Kosovar blood donors were used to assess specificity. All samples were tested with two IgM/IgG immunofluorescence assays (IFA) from BNITM, the CCHFV Mosaic 2 IgG and IgM indirect immunofluorescence tests (IIFT) from EUROIMMUN, two BlackBox ELISAs for the detection of CCHFV-specific IgM and IgG antibodies (BNITM), two Anti-CCHFV ELISAs IgM and IgG from EUROIMMUN using recombinant structural proteins of CCHFV antigens, and two ELISAs from Vector-Best (IgM: μ-capture ELISA, IgG: indirect ELISA using immobilized CCHFV antigen). Diagnostic performances were compared between methods using sensitivity, specificity, concordance and degree of agreement with particular focus on the phase of the infection.In early and convalescent phases of infection, the sensitivities for detecting specific IgG antibodies differed for the ELISA test. The BlackBox IgG ELISA yielded the highest, followed by the EUROIMMUN IgG ELISA and finally the VectorBest IgG ELISA with the lowest sensitivities. In the subsided phase, the VectorBest IgM ELISA detected a high rate of samples that were positive for anti-CCHFV IgM antibodies. Both test systems based on immunofluorescence showed an identical sensitivity for detection of anti-CCHFV IgM antibodies in acute and convalescent phases of infection.Available serological test systems detect anti-CCHFV IgM and IgG antibodies accurately, but their diagnostic performances vary with respect to the phase of the infection.  相似文献   

7.
A 28-kDa glutathione S-transferase (Cs28GST) was purified from a Clonorchis sinensis cytosolic fraction through anion-exchange and glutathione-affinity column chromatographies. A monoclonal antibody raised against Cs28GST reacted specifically to the C. sinensis antigen among trematode proteins. A putative peptide of 212 amino residues deduced from a cDNA clone appeared homologous with 28-kDa GST of trematodes, and its secondary structural elements predicted a GSH-binding site. Recombinant Cs28GST showed GST enzyme activity with CDNB substrate and was sensitive to the model inhibitors. The recombinant Cs28GST was antigenically indistinguishable from the native form and was recognized specifically by C. sinensis-infected human sera. The Cs28GST was localized in the tegument and underlying mesenchymal tissues. It is suggested that Cs28GST may play significant physiological roles against bioreactive molecules and be a useful reagent for serodiagnosis of clonorchiasis.  相似文献   

8.
A serodiagnostic ELISA (rL-ELISA) using recombinant truncated leukotoxin protein PL2 (aa 311–644) of Fusobacterium necrophorum as antigen was developed for detection of antibodies against F. necrophorum from cattle footrot. In rL-ELISA, the recombinant diagnostic antigen showed no cross-reaction with antisera against bovine foot and mouth disease virus, bovine rhinotracheitis virus, bovine viral diarrhea virus, bovine rotavirus type A, bovine Escherichia coli, and bovine Salmonella. The rL-ELISA could confirm the existence of antibodies against F. necrophorum at day 7 after infection. Detection of the field samples indicated relative sensitivity of rL-ELISA to nL-ELISA using the purified native leukotoxin A as antigen was 96.43%, and relative specificity of rL-ELISA to nL-ELISA was 94.26%. These data demonstrated the rL-ELISA would have a potential use for early diagnosis of cattle footrot caused by F. necrophorum.  相似文献   

9.
Although stool examination is the standard diagnostic method of clonorchiasis, serodiagnosis by ELISA using crude antigen is now widely used because of its convenience. However, ELISA diagnosis still suffers from cross-reactions, and therefore there is a need to improve the present conventional ELISA. The present study was undertaken to evaluate the diagnostic value of ELISA using excretory-secretory antigen (ESA) instead of crude antigen (CA) of Clonorchis sinensis. The diagnostic sensitivity of ELISA using excretory-secretory antigen was 92.5%, which was higher than that of ELISA using crude Clonorchis sinensis antigen (88.2%). In addition, the specificity of excretory-secretory antigen was found 93.1% while that of crude antigen was 87.8%. In summary, Clonorchis sinensis ESA was found to be a better serodiagnostic antigen than CA for ELISA.  相似文献   

10.
肺炎支原体P1重组蛋白的提取纯化及应用研究   总被引:1,自引:0,他引:1  
提取纯化肺炎支原体(Mycoplasma pneumoniae,Mp)P1重组蛋白,建立酶联免疫吸附实验(ELISA)的方法,协助临床肺炎支原体感染的诊断。以GST融合蛋白层析柱提取、纯化Mp P1重组蛋白做抗原,以全肺炎支原体菌体成分做抗原对照,建立间接ELISA实验方法,检测40份正常献血者血清标本和51份疑似MP感染临床血清标本的IgG抗体。重组蛋白经SDS-PAGE可见诱导表达的样品在分子量大约59 ku处有明显条带,经Western blotting可与肺炎支原体免疫血清发生反应。ELISA实验检测51份临床标本,由P1重组蛋白抗原检测阳性31份,阳性率为60.78%。Mp检测阳性20份,阳性率为39.22%。实验精确度检测阳性混合血清的变异系数(CV值)为5.40%,阴性混合血清变异系数为1.10%。用Mp P1重组蛋白抗原建立的ELISA检测方法,其敏感性高于全肺炎支原体抗原,可用于临床肺炎支原体感染的诊断。  相似文献   

11.
Rapid serodiagnostic methods for Toxoplasma gondii infection in cats are urgently needed for effective control of transmission routes toward human infections. In this work, 4 recombinant T. gondii antigens (SAG1, SAG2, GRA3, and GRA6) were produced and tested for the development of rapid diagnostic test (RDT). The proteins were expressed in Escherichia coli, affinity-purified, and applied onto the nitrocellulose membrane of the test strip. The recombinant SAG1 (rSAG1) showed the strongest antigenic activity and highest specificity among them. We also performed clinical evaluation of the rSAG1-loaded RDT in 182 cat sera (55 household and 127 stray cats). The kit showed 0.88 of kappa value comparing with a commercialized ELISA kit, which indicated a significant correlation between rSAG1-loaded RDT and the ELISA kit. The overall sensitivity and specificity of the RDT were 100% (23/23) and 99.4% (158/159), respectively. The rSAG1-loaded RDT is rapid, easy to use, and highly accurate. Thus, it would be a suitable diagnostic tool for rapid detection of antibodies in T. gondii-infected cats under field conditions.  相似文献   

12.
Bartonella henselae P26 has been identified as an immunodominant antigen expressed during feline infection. We used antisera from cats experimentally infected with B. henselae (n = 6), B. clarridgeiae (n = 4), or B. koehlerae (n = 2) and from a sample of naturally infected cats (B. henselae, n = 34; B. clarridgeiae, n = 1) to evaluate recombinant P26 (rP26) as a serodiagnostic antigen. Immunoblots using antisera from cats infected with B. henselae and B. clarridgeiae reacted strongly with rP26, whereas B. koehlerae antisera did not. A capture ELISA was designed to evaluate the kinetics of rP26 IgG in sera from experimentally infected cats. For B. henselae and B. clarridgeiae antisera, the kinetic profiles of reactivity were similar for rP26 capture ELISA and Bartonella spp. indirect fluorescence assay. However, for B. koehlerae antisera, reactivity in rP26 capture ELISA was consistently low. The serodiagnostic potential of rP26 capture ELISA was evaluated using sera from cats with known Bartonella sp. exposure histories. All 24 (100%) uninfected cats were seronegative, and 33 of 35 (94.3%) cats bacteremic for Bartonella spp. were seropositive. We propose that rP26-based serology can serve as a useful adjunct tool for the diagnosis of feline infection with B. henselae and B. clarridgeiae, but it may not be useful for feline infection with B. koehlerae.  相似文献   

13.
为利用重组的完整弓形虫表面抗原P35 GST蛋白对弓形虫感染进行血清学诊断 ,构建了可表达P35 GST的JM10 9细胞株 .采用亲和层析对融合蛋白进行分离和纯化 ,用SDS 聚丙烯酰胺凝胶电泳 (SDS PAGE)和蛋白质印迹 (Westernblot)分析所表达的蛋白质 ,并用纯化的重组蛋白进行IgM 酶联免疫吸附测定法 (IgM ELISA)检测不同病人血清中的抗 P35抗体 .SDS PAGE分析发现P35 GST重组蛋白的大小约 6 0ku ,为一亲水性蛋白 ,蛋白质印迹分析表明该蛋白与弓形虫阳性感染病人的血清有特异性反应 .利用P35 GST为抗原 ,对 6 0例血清进行IgM ELISA分析 ,发现P35 GST可明显区分近期感染和既往感染 ,在弓形虫的诊断上有很大的应用前景 .  相似文献   

14.
Clonorchis sinensis is a common parasite of man in Korea. Researches on the specific antigens of C. sinensis would be valuable not only because those elucidate the molecular characteristics of this fluke but also because it is applicable to immunodiagnosis. Although many monoclonal antibodies have been used in the field of parasite immunology, few articles on monoclonal antibodies against C. sinensis have been published so far. The aim of this study was to analyze C. sinensis antigens recognized by monoclonal antibodies, and to set up ELISA-inhibition test using C. sinensis specific monoclonal antibodies for improved specificity of immunodiagnostic tests. By fusion between spleen cells of the mice immunized with C. sinensis water-soluble crude adult worm antigens and plasmacytoma cells of mouse origin, 29 hybridoma clones secreting anti-C. sinensis monoclonal antibodies were made, and 8 clones among those were found specific. After cell cloning, isotypes of 6 selected specific monoclonal antibodies were determined to be IgG1, IgG2b and IgA. Four exposed antigenic determinants of natural infection were recognized by different specific monoclonal antibodies. By enzyme-immunoelectrotransfer blot, 10 KD, 34 KD antigenic determinants were found to be reacted with CsHyb 0714-20, CsHyb 0605-10 monoclonal antibodies, respectively. The antigenic determinant recognized by CsHyb 0714-20 monoclonal antibody was revealed to be located at the surface and parenchyme of a parasite by indirect immunofluorescent antibody technique, and those reacted with CsHyb 0605-10, CsHyb 0714-25 monoclonal antibodies were found at the parenchyme and intestine. The antigenic determinant reacted with CsHyb 0605-23 monoclonal antibody was found mainly around the uterine eggs. Four antigenic determinants recognized by specific monoclonal antibodies were all found to be present in the early eluted fractions of C. sinensis antigens separated by Sephadex G-200 gel filtration. By conventional ELISA, 75% of clonorchiasis cases were found positive, but 7.1% of normal controls and 37.5% of paragonimiasis cases showed false positives. However, by ELISA-inhibition test using C. sinensis specific monoclonal antibody (CsHyb 0605-23), 77.1% of clonorchiasis cases were found positive, and there were no false positives in normal controls or paragonimiasis cases, indicating 100% specificity.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

15.
We recently described the first recombinant Schistosoma mansoni protein RP26, which was capable of acute infection diagnosis. The aim of the present work was to further characterize the RP26 diagnostic properties in immunoblot and enzyme-linked immunosorbent (ELISA) assays. Testing sera from uninfected donors and sera from patients with acute or chronic Schistosoma infection by Western blot immunoassay revealed 100% specificity and 100% sensitivity for acute infection identification. Sera from uninfected, acute, and chronic schistosomiasis were also probed for IgG, IgG4, IgA, and IgM reactivity to RP26 plus soluble egg antigens (SEA) in ELISA. The mean IgG reactivity to RP26 by sera from acute schistosomiasis patients was significantly higher than the chronic ones. The IgG4, IgA, and IgM reactivities to RP26 were low and similar in both infected groups. The mean IgA and IgM reactivities to SEA were significantly higher in the group of acute compared to chronic group, whereas mean IgG4 reactivity was higher in chronic group. To estimate the specificity of Schistosoma infection diagnosis sera from patients infected with other different parasites were tested to detect IgG reactivity to RP26 and IgA and IgM reactivity to SEA. For IgA against SEA detection, 72% of sera were positive and 48% of sera were positive for IgM detection. Based on these results we can suggest that detection of sera IgG binding to RP26 is a sensitive and specific method for acute schistosomiasis diagnosis. Therefore, RP26 is a candidate for immunodiagnostic kit development.  相似文献   

16.
Although all mammals, including humans, are vulnerable when they come into direct contact with infected animals, anthrax is primarily a disease of herbivorous animals. In countries like India, cutaneous anthrax is a public health problem in several regions. Hence, a simple and efficacious serodiagnostic assay for large scale surveillance of endemic populations is required. In the present study, a field‐usable, qualitative ELISA was developed for serodiagnosis of human anthrax. Results are assessed on a visual basis and no sophisticated instruments are required. Anti‐protective antigen (PA) IgG was determined by visual examination of ELISA results of 225 human serum samples (160 from healthy humans, 5 from PA vaccinated individuals and 60 from confirmed anthrax cases). Comparison of the ELISA results with the results obtained from optical density values showed compatible sensitivity and specificity. Assay sensitivity, specificity, and positive and negative predictive values were found to be 100%. The developed assay could be a very useful tool for serological diagnosis of anthrax infection in humans.  相似文献   

17.
Rats develop strong resistance to re-infection and super-infection by Clonorchis sinensis. The present study investigated the antibodies present in the sera and bile juice of rats that were primary infected and re-infected with C. sinensis. The serum level of specific IgG antibodies, which were elevated 2 wk of the primary infection, peaked at 4 wk and subsequently remained unchanged even during re-infection. The total IgE level in serum increased slowly from 388 ng / ml to 3,426 ng / ml beginning 2 wk after the primary infection, and remained high up to 8 wk but dropped to a normal level (259 ng / ml) after treatment. In resistant re-infected rats, the serum IgE level increased rapidly and peaked within 1 wk, whereas no increase was observed in immunosuppressed rats. The serum level of specific IgA antibodies was elevated beginning 1 wk after infection, and decreased 4 wk after treatment. The total bile IgA level unchanged during the primary infection but increased in treated and re-infected rats. The elevated levels of serum IgE and bile IgA indicate that these immunoglobulins may be correlated with the development of resistance to re-infection by C. sinensis in rats.  相似文献   

18.
[目的]克隆和表达肺炎嗜衣原体(Chlamydophila pneumoniae,Cpn)蛋白酶样活性因子(CPAF)免疫优势区基因,评价重组蛋白在早期感染诊断中的应用价值.[方法]挑选并克隆出Cpn CPAF免疫优势区基因,构建原核表达载体,诱导表达并纯化重组蛋白,分析其抗原特异性;间接ELISA法检测Cpn参考血清、临床血清标本中的特异性IgM抗体,以及呼吸道感染患者痰咽拭子中的Cpn抗原;检测沙眼衣原体(Chlamydia trachomatis,Ct)临床阳性血清和泌尿生殖道分泌物.[结果]高效表达和纯化出一相对分子量约51.3kDa的重组蛋白;Western blot证明其只与人抗Cpn抗血清发生特异性反应;间接ELISA法检测40份Cpn IgM参考血清,阴性和阳性结果的一致率均为100%(40/40);与"金标准"方法MIF对照,检测300例临床血清标本中的IgM抗体,符合率为98.3%;与PCR试剂对照,检测120份呼吸道感染患者痰咽拭子中的Cpn抗原,符合率为88.3%;检测Ct阳性血清和泌尿生殖道分泌物,与Ct没有交叉反应.[结论]制备的CPAF免疫优势区基因重组蛋白具有良好的抗原性,在Cpn感染早期诊断中具有较高的利用价值.  相似文献   

19.
A rat IgE mAb specific for larval Ag (26 kDa, 56 kDa) has been shown to protect rats against Schistosoma mansoni infection. Immunizations of Lou/M rats performed with this IgE (Ab1) induced the production of antiidiotypic antibodies (Ab2). Moreover, after this Ab2 production, anti-antiidiotypic antibodies (Ab3) were revealed. The screening of Ab3 isotypes showed the presence of IgG Ab3 and more interestingly of IgE Ab3, i.e., the same isotype as Ab1. These IgE and IgG antibodies recognized predominantly the 26-kDa Ag and were cytotoxic for schistosomula in the presence of platelets for IgE Ab3 and eosinophils for IgG Ab3. Both IgE and IgG Ab3 conferred by passive transfer protective immunity to infected rats (up to 50%). Thus the immunization with an IgE mAb led in part to the production of Ab3 of the same isotype as Ab1. In conclusion, these results suggest that the isotype selection of the antibodies of the third generation (Ab3) might be influenced by the Ab1. The respective role of the idiotope and isotype of Ab1 in isotype regulation is discussed.  相似文献   

20.
Strongyloides stercoralis is a widely distributed parasite that infects 30 to 100 million people worldwide. In the United States strongyloidiasis is recognized as an important infection in immigrants and refugees. Public health and commercial reference laboratories need a simple and reliable method for diagnosis of strongyloidiasis to identify and treat cases and to prevent transmission. The recognized laboratory test of choice for diagnosis of strongyloidiasis is detection of disease specific antibodies, most commonly using a crude parasite extract for detection of IgG antibodies. Recently, a luciferase tagged recombinant protein of S. stercoralis, Ss-NIE-1, has been used in a luciferase immunoprecipitation system (LIPS) to detect IgG and IgG4 specific antibodies. To promote wider adoption of immunoassays for strongyloidiasis, we used the Ss-NIE-1 recombinant antigen without the luciferase tag and developed ELISA and fluorescent bead (Luminex) assays to detect S. stercoralis specific IgG4. We evaluated the assays using well-characterized sera from persons with or without presumed strongyloidiasis. The sensitivity and specificity of Ss-NIE-1 IgG4 ELISA were 95% and 93%, respectively. For the IgG4 Luminex assay, the sensitivity and specificity were 93% and 95%, respectively. Specific IgG4 antibody decreased after treatment in a manner that was similar to the decrease of specific IgG measured in the crude IgG ELISA. The sensitivities of the Ss-NIE-1 IgG4 ELISA and Luminex assays were comparable to the crude IgG ELISA but with improved specificities. However, the Ss-NIE-1 based assays are not dependent on native parasite materials and can be performed using widely available laboratory equipment. In conclusion, these newly developed Ss-NIE-1 based immunoassays can be readily adopted by public health and commercial reference laboratories for routine screening and clinical diagnosis of S. stercoralis infection in refugees and immigrants in the United States.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号