首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background—Aim

Massively parallel sequencing (MPS) holds promise for expanding cancer translational research and diagnostics. As yet, it has been applied on paraffin DNA (FFPE) with commercially available highly multiplexed gene panels (100s of DNA targets), while custom panels of low multiplexing are used for re-sequencing. Here, we evaluated the performance of two highly multiplexed custom panels on FFPE DNA.

Methods

Two custom multiplex amplification panels (B, 373 amplicons; T, 286 amplicons) were coupled with semiconductor sequencing on DNA samples from FFPE breast tumors and matched peripheral blood samples (n samples: 316; n libraries: 332). The two panels shared 37% DNA targets (common or shifted amplicons). Panel performance was evaluated in paired sample groups and quartets of libraries, where possible.

Results

Amplicon read ratios yielded similar patterns per gene with the same panel in FFPE and blood samples; however, performance of common amplicons differed between panels (p<0.001). FFPE genotypes were compared for 1267 coding and non-coding variant replicates, 999 out of which (78.8%) were concordant in different paired sample combinations. Variant frequency was highly reproducible (Spearman’s rho 0.959). Repeatedly discordant variants were of high coverage / low frequency (p<0.001). Genotype concordance was (a) high, for intra-run duplicates with the same panel (mean±SD: 97.2±4.7, 95%CI: 94.8–99.7, p<0.001); (b) modest, when the same DNA was analyzed with different panels (mean±SD: 81.1±20.3, 95%CI: 66.1–95.1, p = 0.004); and (c) low, when different DNA samples from the same tumor were compared with the same panel (mean±SD: 59.9±24.0; 95%CI: 43.3–76.5; p = 0.282). Low coverage / low frequency variants were validated with Sanger sequencing even in samples with unfavourable DNA quality.

Conclusions

Custom MPS may yield novel information on genomic alterations, provided that data evaluation is adjusted to tumor tissue FFPE DNA. To this scope, eligibility of all amplicons along with variant coverage and frequency need to be assessed.  相似文献   

2.
3.

Background

Thyroid nodules are common, and approximately 5% of these nodules are malignant. Pleiotrophin (PTN) is a heparin-binding growth factor which is overexpressed in many cancers. The expression of PTN in papillary thyroid cancer (PTC) is unknown.

Method and Findings

74 subjects (age 47 ± 12 y, 15 males) who had thyroidectomy with a histological diagnosis: 79 benign nodules and 23 PTCs (10 classic, 6 tall cell, 6 follicular variant and 1 undetermined). Fine-needle aspiration (FNA) samples were obtained ex vivo from surgically excised tissue and assayed for PTN and thyroglobulin (Tg). Immunohistochemistry (IHC) was performed on tissue sections. In FNA samples, PTN concentration normalized to Tg was significantly higher in PTC than in benign nodules (16 ± 6 vs 0.3 ± 0.1 ng/mg, p < 0.001). In follicular variant of PTC (n = 6), the PTN/Tg ratio was also higher than in benign nodules (1.3 ± 0.6 vs 0.3 ± 0.1 ng/mg, P < 0.001, respectively). IHC showed cytoplasmic localization of PTN in PTC cells.

Conclusion

In ex vivo FNA samples, the PTN to thyroglobulin ratio was higher in PTCs, including follicular variant PTC, than in benign thyroid nodules. The findings raise the possibility that measurement of the PTN to Tg ratio may provide useful diagnostic and/or prognostic information in the evaluation of thyroid nodules.  相似文献   

4.

Background

This study determines ‘correlation constants’ between the gold standard histological measurement of retinal thickness and the newer spectral-domain optical coherence tomography (SD-OCT) technology in adult C57BL/6 mice.

Methods

Forty-eight eyes from adult mice underwent SD-OCT imaging and then were histologically prepared for frozen sectioning with H&E staining. Retinal thickness was measured via 10x light microscopy. SD-OCT images and histological sections were standardized to three anatomical sites relative to the optic nerve head (ONH) location. The ratios between SD-OCT to histological thickness for total retinal thickness (TRT) and six sublayers were defined as ‘correlation constants’.

Results

Mean (± SE) TRT for SD-OCT and histological sections was 210.95 µm (±1.09) and 219.58 µm (±2.67), respectively. The mean ‘correlation constant’ for TRT between the SD-OCT and histological sections was 0.96. The retinal thickness for all sublayers measured by SD-OCT vs. histology were also similar, the ‘correlation constant’ values ranged from 0.70 to 1.17. All SD-OCT and histological measurements demonstrated highly significant (p<0.01) strong positive correlations.

Conclusion

This study establishes conversion factors for the translation of ex vivo data into in vivo information; thus enhancing the applicability of SD-OCT in translational research.  相似文献   

5.

Purpose

To assess the measurement variability of subsolid nodules (SSNs) in follow-up situations and to compare the degree of variability between measurement metrics.

Methods

Two same-day repeat-CT scans of 69 patients (24 men and 45 women) with 69 SSNs were randomly assigned as initial or follow-up scans and were read by the same (situation 1) or different readers (situation 2). SSN size and solid portion size were measured in both situations. Measurement variability was calculated and coefficients of variation were used for comparisons.

Results

Measurement variability for the longest and average diameter of SSNs was ±1.3 mm (±13.0%) and ±1.3 mm (±14.4%) in situation 1, and ±2.2 mm (±21.0%) and ±2.1 mm (±21.3%) in situation 2, respectively. For solid portion, measurement variability on lung and mediastinal windows was ±1.2 mm (±27.1%) and ±0.8 mm (±24.0%) in situation 1, and ±3.7 mm (±61.0%) and ±1.5 mm (±47.3%) in situation 2, respectively. There were no significant differences in the degree of variability between the longest and average diameters and between the lung and mediastinal window settings (p>0.05). However, measurement variability significantly increased when the follow-up and initial CT readers were different (p<0.001).

Conclusions

A cutoff of ±2.2 mm can be reliably used to determine true nodule growth on follow-up CT. Solid portion measurements were not reliable in evaluating SSNs’ change when readers of initial and follow-up CT were different.  相似文献   

6.

Objective

To ascertain accurate measurements of, and the relationships between, the normative parameters of the tracheobronchial trees in the Chinese population using multi-slice spiral computed tomography (CT) and multi-planar reconstruction (MPR).

Materials and Methods

Measurements were performed on 2107 patients who underwent thoracic CT scans in the PLA General Hospital. The lengths of the trachea and the main stem bronchi, and the sizes of the subcarinal angle were obtained through CT or MPR imaging. Multi-variance analyses were performed to detect potential correlations between obtained parameters.

Results

The mean length of the trachea was 104.9 ± 13.4 mm (107.8 ± 13.2 mm for men and 101.4 ± 12.8 mm for women). The mean lengths of the right and left main stem bronchi were 13.6 ± 4.3 and 48.3 ± 6.5 mm, respectively. The right bronchus angle and the left bronchus angle were 34.9 and 42.5 degrees, respectively. Significant gender differences were found in all the parameters measured except for the angle of the right upper lobe bronchus. There are no statistically significant correlations among these parameters.

Conclusions

The normal reference values and the likely ranges of distribution of the tracheobronchial trees in the Chinese population have been established. Significant gender differences exist in the dimensions of the trachea, with the exception of the Right upper bronchial angle (RUA).  相似文献   

7.

Background

Neuropilin (NRP) receptors are overexpressed in glioma tumor tissue, and therefore may be a potential target for imaging markers. We investigated whether labelled tLyP-1, an NRP targeting peptide, could be used as the targeting ligand for developing reagents for imaging glioma tumors.

Methods

The tLyP-1 peptide (CGNKRTR) was labeled with 5-carboxyfluorescein (FAM) or 18F-fluoride. A control peptide (MAQKTSH) was also labeled with FAM. The in vitro binding between FAM-tLyP-1 and U87MG cells and in vivo biodistribution of FAM-tLyP-1 in a U87MG glioblastoma xenograft model (nude mouse) were determined. The in vivo biodistribution of 18F-tLyP-1 was also determined by microPET/CT.

Results

In vitro, FAM-tLyP-1 was strongly taken up by U87MG cells at very low concentrations (1μM). In vivo, FAM-tLyP-1 accumulated in glioma (U87MG) tumors, but uptake was minimal in the normal brain tissue 1 h after administration. The distribution of FAM-tLyP-1 in the tumor tissue was consistent with expression of NRP1. The tumor/brain fluorescence intensity ratio in mice treated with FAM-tLyP-1 was significantly higher than the control FAM-labeled peptide 1 h after administration (3.44 ± 0.83 vs. 1.32 ± 0.15; t = 5.547, P = 0.001). Uptake of FAM-tLyP-1 in glioma tumors could be blocked by administering an excess of non-conjugated tLyP-1 peptide. [Lys4] tLyP-1 was labeled with 18F to synthesis a PET (18F-tLyP-1). MicroPET/CT imaging showed the tumor was visualized clearly with a high tumor/brain radiolabel ratio at 60 min (2.69 ± 0.52) and 120 min (3.11±0.25).

Conclusion

Taken together, our results suggest that tLyP-1 could be developed as a novel fluorescent or radio labelled tracer for imaging glioma.  相似文献   

8.

Objective

To evaluate the clinical value of using monochromatic images in spectral CT pulmonary angiography to improve image quality of bronchial arteries.

Methods

We retrospectively analyzed the chest CT images of 38 patients who underwent contrast-enhanced spectral CT. These images included a set of 140kVp polychromatic images and the default 70keV monochromatic images. Using the standard Gemstone Spectral Imaging (GSI) viewer on an advanced workstation (AW4.6,GE Healthcare), an optimal energy level (in keV) for obtaining the best contrast-to-noise ratio (CNR) for the artery could be automatically obtained. The signal-to-noise ratio (SNR), CNR and objective image quality score (1–5) for these 3 image sets (140kVp, 70keV and optimal energy level) were obtained and, statistically compared. The image quality score consistency between the two observers was also evaluated using Kappa test.

Results

The optimal energy levels for obtaining the best CNR were 62.58±2.74keV.SNR and CNR from the 140kVp polychromatic, 70keV and optimal keV monochromatic images were (16.44±5.85, 13.24±5.52), (20.79±7.45, 16.69±6.27) and (24.9±9.91, 20.53±8.46), respectively. The corresponding subjective image quality scores were 1.97±0.82, 3.24±0.75, and 4.47±0.60. SNR, CNR and subjective scores had significant difference among groups (all p<0.001). The optimal keV monochromatic images were superior to the 70keV monochromatic and 140kVp polychromatic images, and there was high agreement between the two observers on image quality score (kappa>0.80).

Conclusions

Virtual monochromatic images at approximately 63keV in dual-energy spectral CT pulmonary angiography yielded the best CNR and highest diagnostic confidence for imaging bronchial arteries.  相似文献   

9.

Introduction

Numerous anti-angiogenic agents are currently developed to limit tumor growth and metastasis. While these drugs offer hope for cancer patients, their transient effect on tumor vasculature is difficult to assess in clinical settings. Confocal laser endomicroscopy (CLE) is a novel endoscopic imaging technology that enables histological examination of the gastrointestinal mucosa. The aim of the present study was to evaluate the feasibility of using CLE to image the vascular network in fresh biopsies of human colorectal tissue. For this purpose we have imaged normal and malignant biopsy tissue samples and compared the vascular network parameters obtained with CLE with established histopathology techniques.

Materials and Methods

Fresh non-fixed biopsy samples of both normal and malignant colorectal mucosa were stained with fluorescently labeled anti-CD31 antibodies and imaged by CLE using a dedicated endomicroscopy system. Corresponding biopsy samples underwent immunohistochemical staining for CD31, assessing the microvessel density (MVD) and vascular areas for comparison with CLE data, which were measured offline using specific software.

Results

The vessels were imaged by CLE in both normal and tumor samples. The average diameter of normal vessels was 8.5±0.9 µm whereas in tumor samples it was 13.5±0.7 µm (p = 0.0049). Vascular density was 188.7±24.9 vessels/mm2 in the normal tissue vs. 242.4±16.1 vessels/mm2 in the colorectal cancer samples (p = 0.1201). In the immunohistochemistry samples, the MVD was 211.2±42.9/mm2 and 351.3±39.6/mm2 for normal and malignant mucosa, respectively. The vascular area was 2.9±0.5% of total tissue area for the normal mucosa and 8.5±2.1% for primary colorectal cancer tissue.

Conclusion

Selective imaging of blood vessels with CLE is feasible in normal and tumor colorectal tissue by using fluorescently labeled antibodies targeted against an endothelial marker. The method could be translated into the clinical setting for monitoring of anti-angiogenic therapy.  相似文献   

10.

Purpose

Senescence is a terminal growth arrest that functions as a tumor suppressor in aging and precancerous cells and is a response to selected anticancer compounds. Lysosomal-β-galactosidase (GLB1) hydrolyzes β-galactose from glycoconjugates and is the origin of senescence-associated β-gal activity (SA-β-gal). Using a new GLB1 antibody, senescence biology was investigated in prostate cancer (PCa) tissues.

Experimental Design

In vitro characterization of GLB1 was determined in primary prostate epithelial cell cultures passaged to replicative senescence and in therapy-induced senescence in PCa lines using chemotherapeutic agents. FFPE tissue microarrays were subjected to immunofluorescent staining for GLB1, Ki67 and HP1γ and automated quantitative imaging initially using AQUA in exploratory samples and Vectra in a validation series.

Results

GLB1 expression accumulates in replicative and induced senescence and correlates with senescent morphology and P16 (CDKN2) expression. In tissue arrays, quantitative imaging detects increased GLB1 expression in high-grade prostatic intraepithelial neoplasia (HGPIN), known to contain senescent cells, and cancer compared to benign prostate tissues (p<0.01) and senescent cells contain low Ki67 and elevated HP1γ. Within primary tumors, elevated GLB1 associates with lower T stage (p=0.01), localized versus metastatic disease (p=0.0003) and improved PSA-free survival (p=0.03). Increased GLB1 stratifies better PSA-free survival in intermediate grade PCa (0.01). Tissues that elaborate higher GLB1 display increased uniformity of expression.

Conclusion

Increased GLB1 is a valuable marker in formalin-fixed paraffin-embedded (FFPE) tissues for the senescence-like phenotype and associates with improved cancer outcomes. This protein addresses a lack of senescence markers and should be applicable to study the biologic role of senescence in other cancers.  相似文献   

11.

Purpose

To investigate the changes of intraocular pressure (IOP) induced by 3-diopter (3 D) accommodation in progressing myopes, stable myopes and emmetropes.

Design

Cross-sectional study.

Participants

318 subjects including 270 myopes and 48 emmetropes.

Methods

195 progressing myopes, 75 stable myopes and 48 emmetropes participated in this study. All subjects had their IOP measured using iCare rebound tonometer while accommodative stimuli of 0 D and 3 D were presented.

Main Outcome Measures

IOP values without accommodation and with 3 D accommodation were measured in all subjects. Baseline IOPs and IOP changes were compared within and between groups.

Results

There was no significant difference in IOPs between progressing myopes, stable myopes and emmetropes when no accommodation was induced (17.47±3.46, 16.62±2.98 and 16.80±3.62 respectively, p>0.05). IOP experienced an insignificantly slight decrease after 3 D accommodation in three groups (mean change -0.19±2.16, -0.03±1.68 and -0.39±2.65 respectively, p>0.05). Subgroup analysis showed in progressing myopic group, IOP of children (<18 years old) declined with accommodation while IOP of adults (≥18 years) increased, and the difference was statistically significant (p = 0.008). However, after excluding the age factor, accommodation induced IOP changes of high progressing myopes (≤-6 D), low, moderate and non-myopes (>-6 D) was not significantly different after Bonferroni correction (p = 0.838).

Conclusions

Although no difference was detected between the baseline IOPs and accommodation induced IOP changes in progressing myopes, stable myopes and emmetropes, this study found accommodation could cause transient IOP elevation in adult progressing myopes.  相似文献   

12.

Background

The impact of cardiac surgery using cardiopulmonary bypass (CPB) on the respiratory mucociliary function is unknown. This study evaluated the effects of CPB and interruption of mechanical ventilation on the respiratory mucociliary system.

Methods

Twenty-two pigs were randomly assigned to the control (n = 10) or CPB group (n = 12). After the induction of anesthesia, a tracheostomy was performed, and tracheal tissue samples were excised (T0) from both groups. All animals underwent thoracotomy. In the CPB group, an aorto-bicaval CPB was installed and maintained for 90 minutes. During the CPB, mechanical ventilation was interrupted, and the tracheal tube was disconnected. A second tracheal tissue sample was obtained 180 minutes after the tracheostomy (T180). Mucus samples were collected from the trachea using a bronchoscope at T0, T90 and T180. Ciliary beat frequency (CBF) and in situ mucociliary transport (MCT) were studied in ex vivo tracheal epithelium. Mucus viscosity (MV) was assessed using a cone-plate viscometer. Qualitative tracheal histological analysis was performed at T180 tissue samples.

Results

CBF decreased in the CPB group (13.1 ± 1.9 Hz vs. 11.1 ± 2.1 Hz, p < 0.05) but not in the control group (13.1 ± 1 Hz vs. 13 ± 2.9 Hz). At T90, viscosity was increased in the CPB group compared to the control (p < 0.05). No significant differences were observed in in situ MCT. Tracheal histology in the CPB group showed areas of ciliated epithelium loss, submucosal edema and infiltration of inflammatory cells.

Conclusion

CPB acutely contributed to alterations in tracheal mucocilliary function.  相似文献   

13.

Background & Aims

The amount of drug-loaded lipiodol in an HCC tumor post-transarterial chemoembolization (TACE) correlates with the risk of local tumor recurrence. Lipiodol enhancement of a tumor on conventional CT, measured in Hounsfield units (HU), can predict tumor response. Here we investigate whether cone-beam CT (CBCT) can also be used to predict tumor response, providing the benefit of being able to optimize the patient’s treatment plan intra-procedurally.

Methods

A total of 82 HCC nodules (82 patients), ≤5 cm in diameter, were treated with balloon-occluded TACE using miriplatin between December 2013 and November 2014. For each patient, both CBCT and conventional CT images were obtained post-TACE. The degree of correlation between CBCT and conventional CT was determined by comparing identical regions of interest for each imaging modality using pixel values.

Results

The pixel values from conventional CT and CBCT were highly correlated, with a Pearson correlation coefficient of 0.912 (p<0.001). The location of the nodules within the liver did not affect the results; the correlation coefficient was 0.891 (p<0.001) for the left lobe and 0.926 (p<0.001) for the right lobe. The mean pixel value for conventional CT was 439 ± 279 HU, and the mean pixel value for CBCT was 416 ± 311 HU.

Conclusions

CBCT may be used as a substitute for conventional CT to quantitatively evaluate the amount of drug-loaded lipiodol within an HCC nodule and, hence, the efficacy of TACE treatment. The major benefit of using CBCT is the ability to predict the likelihood of local recurrence intra-procedurally, enabling subsequent treatment optimization.  相似文献   

14.

Objectives:

To describe muscle size and architecture of the gastrocnemius medialis (GM) muscle in eleven adult males with Duchenne Muscular Dystrophy (DMD, age 24.5±5.4 years), and a control group of eleven males without DMD (CTRL, age 22.1±0.9 years).

Methods:

GM anatomical cross sectional area (ACSA), volume (VOL), physiological cross sectional area (PCSA), fascicle length (Lf) and pennation angle (θ) were assessed using B-Mode Ultrasonography. GM ACSA was measured at 25, 50 and 75% of muscle length (Lm), from which VOL was calculated. At 50% of Lm, sagittal plane images were analysed to determine GM Lf and θ. GM PCSA was calculated as VOL/Lf. The ratio of Lf and Lm was also calculated.

Results:

GM ACSA at 50% Lm, VOL and PCSA were smaller in DMD males compared to CTRL males by 36, 47 and 43%, respectively (P<0.01). There were no differences in Lf and θ. GM Lm was 29% shorter in DMD compared to CTRL. Lf/Lm was 29% longer in DMD (P<0.01).

Conclusions:

Unlike previous data in children with DMD, our results show significant atrophy in adult males with DMD, and no change in Lf or θ. The shorter Lm may have implications for joint flexibility.  相似文献   

15.
16.

Purpose

This study aimed to calculate the flexion-extension axis (FEA) of the knee through in-vivo knee kinematics data, and then compare it with two major anatomical axes of the femoral condyles: the transepicondylar axis (TEA) defined by connecting the medial sulcus and lateral prominence, and the cylinder axis (CA) defined by connecting the centers of posterior condyles.

Methods

The knee kinematics data of 20 healthy subjects were acquired under weight-bearing condition using bi-planar x-ray imaging and 3D-2D registration techniques. By tracking the vertical coordinate change of all points on the surface of femur during knee flexion, the FEA was determined as the line connecting the points with the least vertical shift in the medial and lateral condyles respectively. Angular deviation and distance among the TEA, CA and FEA were measured.

Results

The TEA-FEA angular deviation was significantly larger than that of the CA-FEA in 3D and transverse plane (3.45° vs. 1.98°, p < 0.001; 2.72° vs. 1.19°, p = 0.002), but not in the coronal plane (1.61° vs. 0.83°, p = 0.076). The TEA-FEA distance was significantly greater than that of the CA-FEA in the medial side (6.7 mm vs. 1.9 mm, p < 0.001), but not in the lateral side (3.2 mm vs. 2.0 mm, p = 0.16).

Conclusion

The CA is closer to the FEA compared with the TEA; it can better serve as an anatomical surrogate for the functional knee axis.  相似文献   

17.

Background

Low biomass in the bacterial lung tissue microbiome utilizes quantitative PCR (qPCR) 16S bacterial assays at their limit of detection. New technology like droplet digital PCR (ddPCR) could allow for higher sensitivity and accuracy of quantification. These attributes are needed if specific bacteria within the bacterial lung tissue microbiome are to be evaluated as potential contributors to diseases such as chronic obstructive pulmonary disease (COPD). We hypothesize that ddPCR is better at quantifying the total bacterial load in lung tissue versus qPCR.

Methods

Control (n = 16) and COPD GOLD 2 (n = 16) tissue samples were obtained from patients who underwent lung resection surgery, were cut on a cryotome, and sections were assigned for use in quantitative histology or for DNA extraction. qPCR and ddPCR were performed on these samples using primers spanning the V2 region on the 16S rRNA gene along with negative controls. Total 16S counts were compared between the two methods. Both methods were assessed for correlations with quantitative histology measurements of the tissue.

Results

There was no difference in the average total 16S counts (P>0.05) between the two methods. However, the negative controls contained significantly lower counts in the ddPCR (0.55 ± 0.28 16S/uL) than in the qPCR assay (1.00 ± 0.70 16S copies) (P <0.05). The coefficient of variation was significantly lower for the ddPCR assay (0.18 ± 0.14) versus the qPCR assay (0.62 ± 0.29) (P<0.05).

Conclusion

Overall the ddPCR 16S assay performed better by reducing the background noise in 16S of the negative controls compared with 16S qPCR assay.  相似文献   

18.

Background

High resolution μCT, and combined μPET/CT have emerged as non-invasive techniques to enhance or even replace dual energy X-ray absorptiometry (DXA) as the current preferred approach for fragility fracture risk assessment. The aim of this study was to assess the ability of µPET/CT imaging to differentiate changes in rat bone tissue density and microstructure induced by metabolic bone diseases more accurately than current available methods.

Methods

Thirty three rats were divided into three groups of control, ovariectomy and vitamin-D deficiency. At the conclusion of the study, animals were subjected to glucose (18FDG) and sodium fluoride (Na18F) PET/CT scanning. Then, specimens were subjected to µCT imaging and tensile mechanical testing.

Results

Compared to control, those allocated to ovariectomy and vitamin D deficiency groups showed 4% and 22% (significant) increase in 18FDG uptake values, respectively. DXA-based bone mineral density was higher in the vitamin D deficiency group when compared to the other groups (cortical bone), yet μCT-based apparent and mineral density results were not different between groups. DXA-based bone mineral density was lower in the ovariectomy group when compared to the other groups (cancellous bone); yet μCT-based mineral density results were not different between groups, and the μCT-based apparent density results were lower in the ovariectomy group compared to the other groups.

Conclusion

PET and micro-CT provide an accurate three-dimensional measurement of the changes in bone tissue mineral density, as well as microstructure for cortical and cancellous bone and metabolic activity. As osteomalacia is characterized by impaired bone mineralization, the use of densitometric analyses may lead to misinterpretation of the condition as osteoporosis. In contrast, µCT alone and in combination with the PET component certainly provides an accurate three-dimensional measurement of the changes in both bone tissue mineral density, as well as microstructure for cortical and cancellous bone and metabolic activity.  相似文献   

19.

Aim

To determine the optimal dose reduction level of iterative reconstruction technique for paediatric chest CT in pig models.

Materials and Methods

27 infant pigs underwent 640-slice volume chest CT with 80kVp and different mAs. Automatic exposure control technique was used, and the index of noise was set to SD10 (Group A, routine dose), SD12.5, SD15, SD17.5, SD20 (Groups from B to E) to reduce dose respectively. Group A was reconstructed with filtered back projection (FBP), and Groups from B to E were reconstructed using iterative reconstruction (IR). Objective and subjective image quality (IQ) among groups were compared to determine an optimal radiation reduction level.

Results

The noise and signal-to-noise ratio (SNR) in Group D had no significant statistical difference from that in Group A (P = 1.0). The scores of subjective IQ in Group A were not significantly different from those in Group D (P>0.05). There were no obvious statistical differences in the objective and subjective index values among the subgroups (small, medium and large subgroups) of Group D. The effective dose (ED) of Group D was 58.9% lower than that of Group A (0.20±0.05mSv vs 0.48±0.10mSv, p <0.001).

Conclusions

In infant pig chest CT, using iterative reconstruction can provide diagnostic image quality; furthermore, it can reduce the dosage by 58.9%.  相似文献   

20.

Background

Smokers have increased cell concentration in the lower respiratory tract indicating a chronic inflammatory state, which in some individuals may lead to development of chronic obstructive pulmonary disease (COPD). Computer tomography (CT) imaging provides means of quantifying pulmonary structure and early signs of disease. We investigated whether lung density on high resolution CT differs between smokers and never-smokers and if this were associated to intensity of inflammation.

Methods

Forty smoking volunteers with normal pulmonary function, 40 healthy never-smokers and 40 patients with COPD of GOLD stage I-II, were included. Mean lung attenuation and percentage of pixels in the lung with attenuation between −750 and −900 HU (percentage higher density spectrum (%HDS)) were calculated on inspiratory CT-scans. Markers of systemic inflammation in blood and cell counts in bronchoalveolar lavage (BAL) fluid were recorded.

Results

Lung density expressed as %HDS was increased in smokers (44.0 ± 5.8%) compared to both never-smokers (38.3 ± 5.8%) and patients with COPD (39.1 ± 5.8%), (p < 0.001, for both). Females had denser lungs than males, which was dependent on body height. Cell concentration in BAL were correlated to lung density in smokers (r = 0.50, p < 0.001).

Conclusions

Lung density on CT is associated with cell concentration in BAL in smokers and may mirror an inflammatory response in the lung. Gender difference in lung density is dependent on height. In COPD with emphysema, loss of lung tissue may counterbalance the expected increase in density due to inflammation. The findings may help to interpret high resolution CT in the context of smoking and gender and highlight the heterogeneity of structural changes in COPD.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号