首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and sensitive method was developed for the quantification of amikacin in human plasma and urine samples. The method involves centrifugation of body fluid plasma after dilution with an ethanol/sodium carbonate mixture, and then an aliquot of the supernatant is directly injected into the chromatograph. After separation on a reversed-phase C18 column (runtime 20 min), aminoglycoside is detected on the basis of its complex formation reaction with Cu(II), the catalyst of the luminol/hydrogen peroxide chemiluminescence system. Using a volume of 500 microl biological sample, linearity is established over the concentration range 0.15-2.0 microg/ml and the limit of detection (LOD) is ca. 50 microg/l in plasma or urine. The intra-day and inter-day precision (measured by relative standard deviation, R.S.D.%) are always less than 9%, and relative recoveries are found to be over 92%.  相似文献   

2.
Atomoxetine is the first, non-stimulant alternative to other stimulant medications used for the treatment of Attention-Deficit/Hyperactivity Disorder (ADHD). Reported methods for the determination of atomoxetine include expensive liquid chromatography tandem mass spectrometry (LCMS) and high performance liquid chromatography (HPLC) with liquid scintillation counting (LSC) detection. Till date, no method has been reported in literature to determine atomoxetine using HPLC with UV detection. In this paper, we describe a new HPLC method for the determination of atomoxetine using liquid-liquid extraction with tertiary butyl methyl ether and UV detector. This method was found to be linear over the concentration range of 0.05-3.0 microg/ml. The limit of quantification was 0.05 microg/ml. Intra- and inter-day precision was <15% and accuracy was in the range of 95.67-108.80%. Stability studies showed that atomoxetine was stable in human plasma for short- and long-term period for sample preparation and analysis. This method was used for sample analysis in a pharmacokinetic study of atomoxetine (25mg) in five healthy adult female volunteers. The observed mean+/-S.D. pharmacokinetic parameters Cmax, Tmax and AUC(0-t) were 0.40+/-0.06 microg/ml, 3.40+/-0.42 h and 1.34+/-0.52 microg h/ml, respectively.  相似文献   

3.
A liquid chromatography-mass spectrometry (LC-MS) method was developed for the analysis of vancomycin (VCM) in human serum. The method was based on full scan data with extracted ions for the accurate masses of VCM and the atenolol internal standard obtained by Fourier transform MS. VCM was extracted from serum using strong cation exchange (SCX) solid phase extraction (SPE). The method was found to be linear in the range 0.05-10 microg/ml, which was adequate for quantification of VCM in serum samples, with a limit of quantification (LOQ) of 0.005 microg/ml and a limit of detection (LOD) of 0.001 microg/ml. Intra-day precision (n=5) was +/-3.5%, +/-2.5%, +/-0.7% at 0.05, 0.5 and 5 microg/ml, respectively. Inter-day precision (n=5) was +/-7.6%, +/-6.4%, +/-3.9% at 0.05, 0.5 and 5 microg/ml, respectively. The process efficiency for VCM was in the range 89.2-98.1% with the recovery for the atenolol internal standard (IS) being 97.3%. The method was used to determine VCM levels in patients during peri-operative infusion of the drug, which was found to result in drug levels within the required therapeutic window.  相似文献   

4.
A modified specific, sensitive and reproducible chiral gas chromatographic (GC) method for the resolution and quantification of ethosuximide enantiomers in urine and plasma was developed. The samples were extracted by liquid-liquid extraction, using diethylether and the enantiomers were separated and quantified on a chiral gas chromatographic column (25QC2 / CYDEX- beta 0.25). The method involved the use of GC/MS instrumentation for the acquisition of data in the electron impact selective-ion monitoring mode, collecting ions characteristic of both ethosuximide and alpha, alpha - dimethyl - beta - methylsuccinimide, the internal standard and of mass-to-charge ratio (m/z) exactly equal to 55 and 70 units. The limit of quantitation of the method was 2.5 microg/ml for both urine and plasma with both enantiomers. The method proved to be linear, precise and reproducible in the 5-300 microg/ml concentration range for urine samples and in the 10-250 microg/ml concentration range for plasma samples. Future research work envisaged the application of this method in pharmacokinetic and pharmacodynamic studies.  相似文献   

5.
A rapid, sensitive and accurate high-performance liquid chromatographic method with UV detection was developed and validated for the quantification of gabapentin in human plasma. Gabapentin was quantified using pre-column derivatization with 1-fluoro-2,4-dinitrobenzene following protein precipitation of plasma with acetonitrile. Amlodipine was used as internal standard. The chromatographic separation was carried out on a Nova-Pak C(18) column using a mixture of 50 mM NaH(2)PO(4) (pH=2.5)-acetonitrile (30:70, v/v) as mobile phase with UV detection at 360 nm. The flow rate was set at 1.5 ml/min. The method was linear over the range of 0.05-5 microg/ml of gabapentin in plasma (r(2)>0.999). The within-day and between-day precision values were in the range of 2-5%. The limit of quantification of the method was 0.05 microg/ml. The method was successfully used to study the pharmacokinetics of gabapentin in healthy volunteers.  相似文献   

6.
A high-performance liquid chromatographic (HPLC) assay for quantification of lipopolysaccharides (LPSs, endotoxins) in outer membrane vesicle vaccines against meningococcal disease has been developed. The LPS constituent, 3-hydroxy-lauric acid, served as marker substance for the quantification. LPS from the vaccine was precipitated by ethanol and the fatty acid constituents, including 3-hydroxy-lauric acid, were released by acidic hydrolysis, collected and purified by solid phase extraction on C18 disc-cartridges and converted into phenacyl esters for UV detection at 240 nm. Quantification of the derivatized 3-hydroxy-lauric acid was achieved by HPLC using a Brownlee RP-18 reversed phase column with acetonitrile/water (68:32, v/v) as mobile phase. The method was found to be linear over the range 3-49 microg LPS/ml with a sensitivity of 1.6 (microg/ml)(-1). The repeatability (within-day precision) of the method at three levels (3-49 microg LPS/ml) was 6-14% relative standard deviation and the intermediate (between-day) precision was 7% relative standard deviation (at level 15 microg LPS/ml). The method has been successfully used in the quality control of a meningococcal B outer membrane vesicle vaccine, containing 4-8% LPS relative to protein (w/w), in our laboratory for three years.  相似文献   

7.
A simple and sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) method to determine the enantiomers of the muscle relaxant baclofen in human plasma and cerebrospinal fluid (CSF) has been developed. A commercially available ultrafiltration membrane is used to prepare the sample. A chiral CROWNPAK CR(+) stationary phase column is then used to perform complete resolution of the S(+)- and R(-)-enantiomers of baclofen. This method was used to analyze human plasma and CSF spiked with baclofen, and the calibration curves for both biologic samples were linear over a concentration range of 0.15-150 ng enantiomer/ml. The lower limit of quantification was 0.15 ng enantiomer/ml in both fluids. Finally, the method was tested with an artificial CSF as an alternative to authentic human CSF. The results showed that no matrix effects and no interfering peaks were observed using this artificial CSF.  相似文献   

8.
Sodium tanshinone IIA sulfonate (STS), a hydrophilic ionic substance, is used as a cardiovascular drug. An ion-pair reversed-phase high-performance liquid chromatography (IP-RP-HPLC) method for the determination of STS in mouse plasma was initially developed. The assay involved a rapid and simple extraction process and subsequent detection at 271 nm. The retention time for STS was 7.5 min. Based on extracted STS standard mouse plasma at 1.5,10 and 50 microg/ml, the assay precision were 2.7, 2.1 and 1.7% with a mean accuracy of 96.7, 98.5 and 99.4%, respectively. At plasma concentration of 1.5, 50 and 75 microg/ml, the mean recovery of STS were 93.1, 96.3 and 97.5%. The limit of detection (LOD) and limit of quantification (LOQ) for STS was 0.1 microg/ml and 0.5 microg/ml, respectively. Linear responses were observed over a wide concentration range (0.5-100 microg/ml) for STS in mouse plasma. STS can be detected after intravenous administration. This method was performed for the first time in pharmacokinetic studies of STS in the mouse.  相似文献   

9.
A simple method for the quantification of tipranavir, the first non-peptidic HIV protease inhibitor, was developed and validated. Quinoxaline, as internal standard, was added to 50 microl of plasma before a liquid-liquid extraction by 600 microl of protein precipitation solution. The extracts were diluted before being injected in the chromatographic system. Chromatographic separation was made on a C18 column using potassium phosphate buffer (pH 3.2) and acetonitrile with gradient. Detection was performed by an UV detector at 260 nm. Relative error at three control quality concentrations ranged from -1.81 to 1.72%. Intra-day (CV%) and inter-day (CV%) precision ranged from 0.94 to 2.55% and from 3.07 to 4.24%, respectively. LOQ and LOD were 0.090 microg/ml and 0.035 microg/ml, respectively. Mean recovery was 87.1%+/-2.4%. Calibration curve was linear up to 180 microg/ml. Concentration range when optimized (0.703-180 microg/ml) proved to be adequate to measure tipranavir concentration in HIV-1-positive patients, therefore this method could be suitable for therapeutic drug monitoring of this drug.  相似文献   

10.
A sensitive reversed-phase high-performance liquid chromatographic (RP-HPLC) assay with on-line extraction was developed for quantifying ertapenem in human cerebrospinal fluid (CSF). This assay is at least five times more sensitive than previously published ertapenem methods with a lower limit of quantitation at 0.025 microg/ml. In this assay, a CSF sample is extracted on-line using a RP extraction column and an aqueous acidic mobile phase (0.1% formic acid) to wash away polar endogenous materials, while ertapenem is retained on the column. Ertapenem is then back-flushed off the extraction column and directed to a RP analytical column using an acidic mobile phase with an organic modifier (acetonitrile/0.1% formic acid, 15:85 (v/v)) and detected using UV absorbance. The acidic mobile phase provided a sharper chromatographic peak and on-line extraction allowed large injection volumes (> or = 150 microl) of buffered CSF to be injected without compromising column integrity. These assay conditions were necessary to quantify ertapenem at levels expected to be found in human CSF (< 0.05 microg/ml). The method was successfully validated and implemented for a clinical study: intraday precision and accuracy of the CSF assay for calibration standards (0.025-10 microg/ml) and quality control samples (0.1, 0.5, and 2.5 microg/ml) were < 6.2% coefficient of variation and 96.8-104.0% of nominal concentration, respectively.  相似文献   

11.
An aminoglycoside antibiotic, amikacin, is used to treat severe and recurring bacterial infections. Due to the absence of a chromophore, however, amikacin must be extensively derivatized before being quantified, both in analytical and bioanalytical samples. In this study, for the first time, we developed a simple and sensitive method for measuring amikacin sulfate using spectrofluorimetry with a 96-well plate reader, based on the design of the experiment's approach. To develop a robust and reproducible spectrofluorimetric method, the influence of essential attributes, namely pH of the buffer, heating temperature, and concentration of reagents, were evaluated using univariate analysis followed by multivariate analysis (central composite design). International Conference of Harmonization guidelines were used to validate the optimized method. The developed technique is linear from 1.9 to 10 μg/ml with a regression coefficient of 0.9991. The detection and quantification limits were 0.649 μg/ml and 1.9 μg/ml, respectively. For the developed method, both intraday and interday precision (%RSD) were less than 5%. Using the method, amikacin concentrations were quantified in prepared amikacin liposomes and commercial formulations of Amicin®. The developed method greatly reduces sample volume and is a rapid, high throughput microplate-based fluorescence approach for the convenient and cost-effective measurement of amikacin in pharmaceutical formulations. In comparison with previously published approaches, the suggested method allowed for quick analysis of a high number of samples in a short amount of time (96 samples in 125 sec), resulting in an average duration of analysis of 1.3 sec per sample.  相似文献   

12.
We have developed and validated an assay, using liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS), for the quantification of the novel protease inhibitors (PIs) atazanavir and tipranavir. The sample pre-treatment consisted of protein precipitation with a mixture of methanol and acetronitrile using 100 microl plasma for atazanavir and 50 microl for tipranavir. Chromatographic separation was achieved on an Inertsil ODS3 column (50 mm x 2.0 mm i.d., particle size 5 microm), with a quick stepwise gradient using an acetate buffer (pH 5) and methanol, at a flow rate of 0.5 ml/min. The analytical run time was 5.5 min. The triple quadrupole mass spectrometer operated in the positive ion-mode and multiple reaction monitoring (MRM) was used for drug quantification. The assay was linear over a concentration range of 0.05-10 microg/ml for atazanavir and 0.1-75 microg/ml for tipranavir. Saquinavir-d5 was used as internal standard. The intra- and inter-day coefficients of variation were less than 3.8% for atazanavir and less than 10.4% for tipranavir. Accuracies were within +/-7.3 and +/-7.2% for atazanavir and tipranavir, respectively. Both drugs were stable under various relevant storage conditions. The validated concentration ranges proved to be adequate to measure concentrations of human immunodeficiency virus type-1 (HIV-1)-infected individuals. The developed method could easily be combined with a previously developed LC-MS/MS assay for the quantification of protease inhibitors.  相似文献   

13.
A simple, rapid, and sensitive method based on gas chromatography with flame ionization detection is described for the determination of finasteride in tablets. The method is based on the derivatization of finasteride with N,O-bis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 60 degrees C for 30 min. The method was validated for specificity, linearity, precision, accuracy, robustness, and limit of quantification. The degree of linearity of the calibration curves, the percentage recoveries of finasteride, and the limit of detection (LOD) and limit of quantification (LOQ) for the gas chromatographic method were determined. The assay was linear over the concentration range of 10 to 50 microg ml(-1) (R approximately 0.999). LOQ and LOD (signal/noise ratio = 10) were found to be 10 and 2 microg ml(-1), respectively. The method was found to be simple, specific, precise, accurate, and reproducible. All of the validation parameters were within the acceptance range. The developed method was applied successfully to estimate the amount of finasteride in tablets. The results were compared statistically with those obtained by the official method using t and F tests. There was no significant difference between the two methods with respect to mean values and standard deviations at the 95% confidence level.  相似文献   

14.
A method for the simultaneous determination of sulfadiazine and trimethoprim in plasma from Beagle dogs was developed and validated. Samples were deproteinized with acetonitrile and extracted with ethyl acetate. Sulfachloropyridazine and ormethoprim were used as internal standards for the sulfadiazine and trimethoprim analysis, respectively. The chromatography was carried out both on an LC-UV (liquid chromatography-ultraviolet detection) and ion-trap LC-MS(n) (liquid chromatography-mass spectrometric detection) instrument, operating in the positive APCI mode (atmospheric pressure chemical ionization). The purpose of this work was to compare the quantification results of both methods. Both the LC-UV and LC-MS-MS methods were validated for their linearity, accuracy, precision, limit of detection and limit of quantification, according to the requirements defined by the European Community. Calibration curves using plasma fortified between 0.1 and 1 microg/ml of sulfadiazine, 0.1 and 2 microg/ml of trimethoprim, 1 and 20 microg/ml of sulfadiazine showed a good linear correlation (r> or =0.9990, goodness-of-fit< or =8.4%). The results for the accuracy and precision at 1 microg/ml of sulfadiazine and trimethoprim and at 20 microg/ml of sulfadiazine fell within the ranges specified. The limits of quantification of both methods were 0.1 microg/ml. The limits of detection were 0.019 microg/ml of sulfadiazine and 0.024 microg/ml of trimethoprim for the LC-UV method, and 0.020 microg/ml of sulfadiazine and 0.062 microg/ml of trimethoprim for the LC-MS-MS method. The methods have been successfully applied in a pharmacokinetic study to determine the drug concentrations in plasma samples from dogs. A good correlation between the results of both methods was observed (R=0.9724, slope=1.0239, intercept=-0.2080 microg/ml for sulfadiazine and R=0.9357, slope=1.0433, intercept=0.0325 microg/ml for trimethoprim). The precision of both methods was also tested on the results of the same samples using an F-test (alpha=0.05), indicating that both methods did not differ in precision.  相似文献   

15.
Qiu J  Wang Q  Zhu W  Jia G  Wang X  Zhou Z 《Chirality》2007,19(1):51-55
A chiral high-performance liquid chromatography method with diode array detector was developed and validated for stereoselective determination of benalaxyl (BX) in rabbit plasma. Good separation was achieved at 20 degrees C using cellulose tris-(3,5-dimethylphenylcarbamate) as chiral stationary phase, a mixture of n-hexane and 2-propanol (97:3) as mobile phase at a flow rate of 1.0 ml/min. The assay method was linear over a range of concentrations (0.25-25 microg/ml) in plasma and the mean recovery was greater than 90% for both enantiomers. The limits of quantification and detection for both enantiomers in plasma were 0.25 and 0.1 microg/ml, respectively. Intra- and interday relative standard deviations (RSDs) did not exceed 10% for three-tested concentrations. The method was successfully applied to pharmacokinetic studies of BX enantiomers in rabbits. The result suggested that the pharmacokinetics of BX enantiomers was stereoselective in rabbits.  相似文献   

16.
Abstract: A method for the quantification of 1-methylimidazole-4-acetic acid in human CSF was developed. Methylimidazole-acetic acid was identified and quantitated in CSF. The method involves concentration of the compound on a cation exchanger, extraction of the methyl ester with ethyl acetate, and preparation of a heptafluorobutyryl derivate of the methyl ester, which is finally purified by chromatography on silica gel and quantitated by gas chromatography-mass spectrometry with the deuterated analogue as internal standard. The coefficient of variation at 1 ng/ml was 13%. The limit of sensitivity was about 0.2 ng/ml. The concentration of methylimidazole-acetic acid in lumbar CSF from healthy volunteers was below 1 ng/ml. Ventricular CSF contained higher concentrations than lumbar fluid. The existence of a rostrocaudal concentration gradient was established. There was a correlation between the concentration of methylimidazole-acetic acid and tele-methylhistamine in CSF. The concentration of methylimidazole-acetic acid in lumbar CSF from schizophrenic patients, patients with subarachnoidal haemorrhage, or patients with rheumatic disease was in the range of that in healthy volunteers.  相似文献   

17.
Iodixanol is a widely used iso-osmolar contrast medium agent. Similar to iohexol, it can also be a good exogenous marker for the measurement of glomerular filtration rate (GFR). This article describes the development and validation of an HPLC-UV method for quantification of iodixanol in human plasma. Internal standard, iohexol (20 microl, 1 mg/ml), and perchloric acid (30 microl, 20%, v/v) were added to plasma samples (300 microl), followed by neutralization with 10 microl potassium carbonate (5M). Samples were centrifuged and 10 microl of the supernatant was injected onto a C(18) EPS analytical column (3 microm particle size, 150 mm x 4.6 mm). The extraction method yielded >95% recovery for both iodixanol and iohexol. The mobile phase consisted of 0.1% (w/v) sodium formate buffer and acetonitrile. Iohexol and iodixanol peaks were eluted at approximately 5 and 9 min, respectively using a fast gradient method. The assay lower limit of detection was 2.0 microg/ml and lower limit of quantification was 10 microg/ml. The calibration curves, assessed in six replicates, were linear over an iodixanol concentration range of 10-750 microg/ml. Intra- and inter-day accuracy was >95% and precision expressed as % coefficient of variation was <10%. This method is simple, accurate, precise and robust and can potentially be used for iodixanol quantification in large-scale clinical studies.  相似文献   

18.
In this research project, a high-performance liquid chromatography (HPLC) method was developed for the determination of acyclovir (ACV) in plasma. The plasma samples, recharged with acyclovir and in presence of 5'-N-methylcarboxyamidoadenosine (MECA) as an internal standard, were purified using a solid-phase extraction technique with Waters Oasis HLB columns. The separation of the components from the extract was carried out in a LiChrospher 100 RP-18 column for further ultraviolet detection at a wavelength range of 250-260 nm. The mobile phase composition was 18% acetonitrile, sodium dodecylsulphate 5 mM and phosphate buffer at pH 2.6 with an analysis time of 13 min per sample. The average retention time for acyclovir was of 5.0 min and for the internal standard 11.2 min. The calibration curve was linear ranging between 0.05 and 1.80 microg/ml. The detection limit was 0.006 microg/ml with a quantification limit of 0.020 microg/ml. The ACV recuperation percentage for 250 microl of plasma was between 94.7 and 109.7% with a coefficient of variation not higher than 5.2%. This method was developed and validated for use in bioavailability and bioequivalence studies.  相似文献   

19.
A simple and sensitive high-performance liquid chromatographic method was developed for the simultaneous determination of dihydromyricetin (1) and myricetin (2) in rat plasma after orally administrating the decoction of Ampelopsis grossedentata. Plasma samples were acidified with 0.375% phosphoric acid and extracted with ethyl acetate. Analysis of the extract was performed on reversed-phase C(18) column with a gradient eluent composed of acetonitrile and 0.04% phosphoric acid. The flow rate was kept at 1 ml/min and the detection wavelength was set at 290 and 370 nm for 1 and 2, respectively. The calibration curves were linear in the range of 0.247-4.114 microg/ml and 0.150-2.501 microg/ml for 1 and 2, respectively. The intra-day and inter-day precisions were better than 4.9 and 6.2%, respectively. The limits of detection (LOD) for 1 and 2 in plasma were 21.600 and 52.530 ng/ml, and the limits of quantification (LOQ) were 0.247 and 0.150 microg/ml, respectively. The mean recoveries for 1 and 2 were 92.0 and 93.3%, respectively. The accuracy and precision were well within the acceptable range and R.S.D. of measured rat samples was less than 7.5%. This validated method has been successfully applied in the pharmacokinetics study of dihydromyricetin and myricetin in vivo after orally administrating the decoction of A. grossedentata to rats.  相似文献   

20.
A simple, rapid, specific, precise, accurate and sensitive method for determination of WCK 771 in human serum has been developed. The method uses high performance liquid chromatography with tandem mass spectrometric detection. Sample preparation involves protein precipitation method by addition of acetonitrile. Gatifloxacin was used as internal standard. The response was found to be linear from 0.312 to 40 microg/ml of serum with correlation coefficient greater than 0.99. Limit of detection and lower limit of quantification for WCK 771 was found to be 0.078 microg/ml and 0.312 microg/ml, respectively. The intra-day precision and accuracy from analysis of quality control (QC) samples at four concentrations was in the range of 2.36-2.58% and from 96.71 to 103.2%, respectively. The inter-day precision and accuracy from analysis of quality control samples at four concentrations was in the range of 3.14-6.82% and from 96.84 to 105.76%, respectively. WCK 771 was found to be stable for 24 h at auto-injector environment. WCK 771 was also found to be stable for 2h in serum at 25+/-3 degrees C and for 3 months at -20 degrees C. Mean absolute recovery at four different concentrations was 86.92% with standard deviation of 1.79. Throughput of the method is approximately one sample every 4 min. The method was also reproduced with monkey serum. The method was employed for estimation of drug serum levels during pre-clinical and clinical trials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号