首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Bone contact forces on the distal tibia during the stance phase of running   总被引:1,自引:0,他引:1  
Although the tibia is a common site of stress fractures in runners, the loading of the tibia during running is not well understood. An integrated experimental and modeling approach was therefore used to estimate the bone contact forces acting on the distal end of the tibia during the stance phase of running, and the contributions of external and internal sources to these forces. Motion capture and force plate data were recorded for 10 male runners as they ran at 3.5-4 m/s. From these data, the joint reaction force (JRF), muscle forces, and bone contact force on the tibia were computed at the ankle using inverse dynamics and optimization methods. The distal end of the tibia was compressed and sheared posteriorly throughout most of stance, with respective peak forces of 9.00+/-1.13 and 0.57+/-0.18 body weights occurring during mid stance. Internal muscle forces were the primary source of tibial compression, whereas the JRF was the primary source of tibial shear due to the forward inclination of the leg relative to the external ground reaction force. The muscle forces and JRF both acted to compress the tibia, but induced tibial shear forces in opposing directions during stance, magnifying tibial compression and reducing tibial shear. The superposition of the peak compressive and posterior shear forces at mid stance may contribute to stress fractures in the posterior face of the tibia. The implications are that changes in running technique could potentially reduce stress fracture risk.  相似文献   

2.
The functional adaptation of juvenile mammalian limb bone to mechanical loading is necessary to maintain bone strength. Diaphyseal size and shape are modified during growth through the process of bone modeling. Although bone modeling is a well-documented response to increased mechanical stress on growing diaphyseal bone, the effect of proximodistal location on bone modeling remains unclear. Distal limb elements in cursorial mammals are longer and thinner, most likely to conserve energy during locomotion because they require less energy to move. Therefore, distal elements are hypothesized to experience greater mechanical loading during locomotion and may be expected to exhibit a greater modeling response to exercise. In this study, histomorphometric comparisons are made between femora and tibiae of mice treated with voluntary exercise and a control group (N = 20). We find that femora of exercised mice exhibit both greater bone growth rates and growth areas than do controls (P < 0.05). The femora of exercised mice also have significantly greater cortical area, bending rigidity, and torsional rigidity (P < 0.05), although bending and torsional rigidity are comparable when standardized by bone length. Histomorphometric and cross-section geometric properties of the tibial midshaft of exercised and control mice did not differ significantly, although tibial length was significantly greater in exercised mice (P < 0.05). Femora of exercised mice were able to adapt to increased mechanical loading through increases in compressive, bending, and torsional rigidity. No such adaptations were found in the tibia. It is unclear if this is a biomechanical adaptation to greater stress in proximal elements or if distal elements are ontogenetically constrained in a tradeoff of bone strength of distal elements for bioenergetic efficiency during locomotion.  相似文献   

3.
Articular cartilage and its supporting bone functional conditions are tightly coupled as injuries of either adversely affects joint mechanical environment. The objective of this study was set to quantitatively investigate the extent of alterations in the mechanical environment of cartilage and knee joint in presence of commonly observed osteochondral defects. An existing validated finite element model of a knee joint was used to construct a refined model of the tibial lateral compartment including proximal tibial bony structures. The response was computed under compression forces up to 2000 N while simulating localized bone damage, cartilage–bone horizontal split, bone overgrowth and absence of deep vertical collagen fibrils.Localized tibial bone damage increased overall joint compliance and substantially altered pattern and magnitude of contact pressures and cartilage strains in both tibia and femur. These alterations were further exacerbated when bone damage was combined with base cartilage split and absence of deep vertical collagen fibrils. Local bone boss markedly changed contact pressures and strain patterns in neighbouring cartilage. Bone bruise/fracture and overgrowth adversely perturbed the homeostatic balance in the mechanical environment of articulate cartilage surrounding and opposing the lesion as well as the joint compliance. As such, they potentially contribute to the initiation and development of post-traumatic osteoarthritis.  相似文献   

4.
Two-dimensional, finite element studies were conducted of the proximal tibia before and after joint arthroplasty. Equivalent-thickness models projected onto the mid-frontal plane were created for the natural, proximal tibia and for the proximal tibia with four different types of tibial plateau components. All components simulated bony ingrowth fixation, i.e. no cement layer existed between component and bone. In addition, the interface between component and bone was assumed to be intimately connected, representing complete bony ingrowth and a rigid state of fixation. Loads consisted of bi-condylar and uni-condylar forces. Results indicated that conventional plateau designs with central posts or multiple pegs led to higher stress magnitudes in the trabecular bone near the distal ends of the post/pegs and stress shielding at more proximal locations. A design without posts or pegs whose interface geometry mimics the epiphyseal plate minimizes bone stress shielding. An implant consisting of separate components covering each condyle was found effective in limiting component tilting and the consequent tensile stresses caused by non-symmetrical, uni-condylar loading.  相似文献   

5.
To enhance new bone formation for the treating of patients with osteopenia and osteoporosis, various mechanical loading regimens have been developed. Although a wide spectrum of loading frequencies is proposed in those regimens, a potential linkage between loading frequencies and locations of loading-induced bone formation is not well understood. In this study, we addressed a question: Does mechanical resonance play a role in frequency-dependent bone formation? If so, can the locations of enhanced bone formation be predicted through the modes of vibration? Our hypothesis is that mechanical loads applied at a frequency near the resonant frequencies enhance bone formation, specifically in areas that experience high principal strains. To test the hypothesis, we conducted axial tibia loading using low, medium, or high frequency to the mouse tibia, as well as finite element analysis. The experimental data demonstrated dependence of the maximum bone formation on location and frequency of loading. Samples loaded with the low-frequency waveform exhibited peak enhancement of bone formation in the proximal tibia, while the high-frequency waveform offered the greatest enhancement in the midshaft and distal sections. Furthermore, the observed dependence on loading frequencies was correlated to the principal strains in the first five resonance modes at 8.0–42.9 Hz. Collectively, the results suggest that resonance is a contributor to the frequencies and locations of maximum bone formation. Further investigation of the observed effects of resonance may lead to the prescribing of personalized mechanical loading treatments.  相似文献   

6.
Yu YY  Lieu S  Hu D  Miclau T  Colnot C 《PloS one》2012,7(2):e31771
Numerous factors can affect skeletal regeneration, including the extent of bone injury, mechanical loading, inflammation and exogenous molecules. Bisphosphonates are anticatabolic agents that have been widely used to treat a variety of metabolic bone diseases. Zoledronate (ZA), a nitrogen-containing bisphosphonate (N-BP), is the most potent bisphosphonate among the clinically approved bisphosphonates. Cases of bisphosphonate-induced osteonecrosis of the jaw have been reported in patients receiving long term N-BP treatment. Yet, osteonecrosis does not occur in long bones. The aim of this study was to compare the effects of zoledronate on long bone and cranial bone regeneration using a previously established model of non-stabilized tibial fractures and a new model of mandibular fracture repair. Contrary to tibial fractures, which heal mainly through endochondral ossification, mandibular fractures healed via endochondral and intramembranous ossification with a lesser degree of endochondral ossification compared to tibial fractures. In the tibia, ZA reduced callus and cartilage formation during the early stages of repair. In parallel, we found a delay in cartilage hypertrophy and a decrease in angiogenesis during the soft callus phase of repair. During later stages of repair, ZA delayed callus, cartilage and bone remodeling. In the mandible, ZA delayed callus, cartilage and bone remodeling in correlation with a decrease in osteoclast number during the soft and hard callus phases of repair. These results reveal a more profound impact of ZA on cartilage and bone remodeling in the mandible compared to the tibia. This may predispose mandible bone to adverse effects of ZA in disease conditions. These results also imply that therapeutic effects of ZA may need to be optimized using time and dose-specific treatments in cranial versus long bones.  相似文献   

7.
Use of the posterior tibial flap pedicled on the posterior tibial vessels has been described by several authors, but with it there is the major disadvantage of an unavoidable transection of the posterior tibial artery. To overcome this disadvantage, we anatomically studied the perforators from the posterior tibial artery and used posterior tibial perforator-based flaps clinically. Based on our anatomic study of 25 cadaveric legs, the cutaneous perforators were considered to be distributed from the distal to the proximal sides of the lower leg through the medial border of the tibia, and they were classified into three types: septocutaneous perforators mainly located in the distal third of the leg, muscle perforators located in the proximal half, and periosteal perforators in the proximal third of the leg. The average size and number of perforators was 0.8 mm and 3.1 in one leg, respectively. A considerable number were located at sites from 70 to 140 mm superior to the medial malleolus. Based on our clinical cases repaired with flaps, we consider this flap to be useful as a free flap for the repair of defects of the extremities and as an island flap for reconstruction of defects on the anteromedial aspect of the lower leg. The territory of the flap is relatively wide, being 19 x 13 cm. The long saphenous vein can be used safely as the venous drainage system in the case of free-flap transfer.  相似文献   

8.
Surgical treatment of proximal humeral fractures remains challenging in elderly patients, primarily due to insufficient implant fixation. Both bone quality and physiological-like loading conditions are commonly overlooked during pre-clinical in vitro evaluation. However, this knowledge is necessary in order to improve surgical treatment of the proximal humerus and the mechanical behavior of implants, particularly in patients with complex fractures and weak bone stock. We hypothesize that the bone quality has a high influence on the bone straining, independent of the arm position. The goal of this study was to determine the straining of the intact and fractured proximal humerus under physiological-like loading conditions. Furthermore, the impact of augmentation on tissue straining was evaluated.

Two representative humeri were selected for this study, one osteoporotic and one reference quality, and scanned using both QCT and DEXA (average DEXA VALUE=0.26 and 0.49 g/cm2 respectively). Subcaptial defects were generated, then stabilized with a plate prior to mechanical stiffness testing. From the QCT data, finite element models were generated and the in vitro stiffness tests analytically simulated. Under physiological-like loading conditions, the straining of the bone and implant were analyzed for 0°, 90° forward flexion, and 90° abduction.

Maximal strain values were found for the intact and fractured bone at 90° abduction. This study demonstrates that the straining in a fractured bone of poor quality leads to considerably higher bone strains (up to +30%) than in a more healthy bone. Augmentation of a central void under physiological-like loading with commercial cement led to mechanical failure at the bone–cement interface.

New concepts for the surgical treatment of complex fractures of the proximal humerus should take bone distribution into account and thereby allow effective treatment of fractures in osteoporotic patients. The ultimate salvage procedure of augmentation has mechanical limitations as long as current cement materials are used in osteoporotic patients.  相似文献   


9.
This report describes a case of a 29-year old patient with congenital pseudoarthrosis of the distal tibia previously treated unsuccessfully by a conventional surgical method. Tibial congenital pseudoarthrosis is a rare disease characterized by segmental osseous weakness resulting in deformation of the bone and spontaneous fractures which progresses to a tibial nonunion. In our case we used intramedullary stabilization with bone grafting and six month after operation congenital pseudarthrosis of the tibia healed.  相似文献   

10.
Prolonged exposure to micro-gravity causes substantial bone loss (Leblanc et al., Journal of Bone Mineral Research 11 (1996) S323) and treadmill exercise under gravity replacement loads (GRLs) has been advocated as a countermeasure. To date, the magnitudes of GRLs employed for locomotion in space have been substantially less than the loads imposed in the earthbound 1G environment, which may account for the poor performance of locomotion as an intervention. The success of future treadmill interventions will likely require GRLs of greater magnitude. It is widely held that mechanical tissue strain is an important intermediary signal in the transduction pathway linking the external loading environment to bone maintenance and functional adaptation; yet, to our knowledge, no data exist linking alterations in external skeletal loading to alterations in bone strain. In this preliminary study, we used unique cadaver simulations of micro-gravity locomotion to determine relationships between localized tibial bone strains and external loading as a means to better predict the efficacy of future exercise interventions proposed for bone maintenance on orbit. Bone strain magnitudes in the distal tibia were found to be linearly related to ground reaction force magnitude (R(2)>0.7). Strain distributions indicated that the primary mode of tibial loading was in bending, with little variation in the neutral axis over the stance phase of gait. The greatest strains, as well as the greatest strain sensitivity to altered external loading, occurred within the anterior crest and posterior aspect of the tibia, the sites furthest removed from the neutral axis of bending. We established a technique for estimating local strain magnitudes from external loads, and equations for predicting strain during simulated micro-gravity walking are presented.  相似文献   

11.
This study set out to establish the effect of transplanting perichondreum on bone healing at sites of tibial bone defects in an experimental dog model. Transplantation of free, autologous, non-vascularised, perichondreal grafts to the distal of right anteromedial plane side of the tibia was compared with non-transplantation on the proximal side of the same bone.

In experimental dogs (n = 7), a 5 cm piece segment of perichondreum, that has been excised from the thirteenth rib of the same animal, was transplanted to the middle defect fracture site of bone, but not to the control proximal defect fracture site.

The dogs were allowed to recover from the operation and were kept 21 days in cages, with free-range. On days 30 (Group I) and 45 (Group II) after operations, the dogs were euthanatized. Histopathologically, defects in 30 days treated perichondreum group were filled by new ossified tissue while control defects in the same period were not fully resurfaced. The new ossified tissue consisted of a thin and inadequate trabeculae. In 45 days treated groups, defects with transplanting perichondreum were filled by thick trabeculae converting into a compact bone tissue. The control defects of this group, however, were filled by an extreme callus overflowing to medulla and bone surface.

This study has provided evidence to show that autologous, non-vascularized perichondreum retains an osteogenic ability when transplanted to tibial bone defect sites. It appears that callus formation occurred within the perichondreum grafting which resembles that of enchondral and intramembranous ossification.  相似文献   


12.
胫骨干骨折是最常见的长骨骨折,对于不稳定的胫骨骨折,胫骨髓内钉因其独特的优势逐渐成为首选治疗方式。当前对于胫骨干髓内钉入路主要分为髌骨上入路和髌骨下入路。髌骨上入路放置髓内钉时,患肢半伸直位有利于胫骨干骨折的复位与固定,但可能会造成髌骨关节面损伤。髌骨下入路患肢屈曲位可能会造成胫骨干复位的丢失,进而影响患者的预后。因此,胫骨髓内钉置入不同入路可能造成不同临床结局,会对临床结局造成不同的影响。目前对于胫骨髓内钉最佳入路仍然存在争议,针对最近发表的相关文献我们对胫骨髓内钉入路及其优缺点进行讨论综述。  相似文献   

13.
Malalignment is the main cause of tibial component loosening. Implants that migrate rapidly in the first two post-operative years are likely to present aseptic loosening. It has been suggested that cancellous bone stresses can be correlated with tibial component migration. A recent study has shown that patient-specific finite element (FE) models have the power to predict the short-term behavior of tibial trays. The stresses generated within the implanted tibia are dependent on the kinematics of the joint; however, previous studies have ignored the kinematics and only applied static loads. Using explicit FE, it is possible to simultaneously predict the kinematics and stresses during a gait cycle. The aim of this study was to examine the cancellous bone strains during the stance phase of the gait cycle, for varying degrees of varus/valgus eccentric loading using explicit FE. A patient-specific model of a proximal tibia was created from CT scan images, including heterogeneous bone properties. The proximal tibia was implanted with a commercial total knee replacement (TKR) model. The stance phase of gait was simulated and the applied loads and boundary conditions were based on those used for the Stanmore knee simulator. Eccentric loading was simulated. As well as examining the tibial bone strains (minimum and maximum principal strain), the kinematics of the bone-implant construct are also reported. The maximum anterior-posterior displacements and internal-external rotations were produced by the model with 20 mm offset. The peak minimum and maximum principal strain values increased as the load was shifted laterally, reaching a maximum magnitude for -20 mm offset. This suggests that when in varus, the load transferred to the bone is shifted medially, and as the bone supporting this load is stiffer, the resulting peak bone strains are lower than when the load is shifted laterally (valgus). For this particular patient, the TKR design analyzed produced the highest cancellous bone strains when in valgus. This study has provided an insight in the variations produced in bone strain distribution when the axial load is applied eccentrically. To the authors' knowledge, this is the first time that the bone strain distribution of a proximal implanted tibia has been examined, also accounting for the kinematics of the tibio-femoral joint as part of the simulation. This approach gives greater insight into the overall performance of TKR.  相似文献   

14.
Long bones respond to mechanical loading through functional adaptation in a suite of morphological characteristics that together ensure structural competence to in vivo loading. As such, adult bone structure is often used to make inferences about past behavior from archaeological remains. However, such biomechanical approaches often investigate change in just one aspect of morphology, typically cross‐sectional morphology or trabecular structure. The relationship between longitudinal bone curvature and mobility patterns is less well understood, particularly in the tibia, and it is unknown how tibial curvature and diaphyseal cross‐sectional geometry interact to meet the structural requirements of loading. This study examines tibial curvature and its relationship with diaphyseal cross‐sectional geometry (CSG) and body size in preindustrial Central Europeans spanning ~6150 years following the introduction of agriculture in the region. Anteroposterior centroid displacement from the proximo‐distal longitudinal axis was quantified at nine diaphyseal section locations (collectively representative of diaphyseal curvature) in 216 tibial three‐dimensional laser scans. Results documented significant and corresponding temporal declines in midshaft centroid displacement and CSG properties. Significant correlations were found between mid‐diaphyseal centroid displacement and all mobility‐related CSG properties, while the relationship weakened toward the diaphyseal ends. No significant relationship was found between centroid displacement and body size variables with the exception of the most distal section location. Results support a relationship between tibial curvature and cross‐sectional geometry among prehistoric Central European agricultural populations, and suggest that changes in mechanical loading may have influenced a suite of morphological features related to bone adaptation in the lower limb. Am J Phys Anthropol 157:260–275, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

15.
Theoretical concerns about the use of cemented or press-fit stems in revision total knee arthroplasty (TKA) include stress shielding with adverse effects on prosthesis fixation. Revision TKA components are commonly stemmed to protect the limited autogenous bone stock remaining. Revision procedures with the use of stems can place abnormal stresses through even normal bone by their constrained design, type of materials and fixation method and may contribute for bone loss. Experimental quantification of strain shielding in the proximal synthetic tibia following TKA is the main purpose of the present study. In this study, cortical bone strains were measured experimentally with tri-axial strain gauges in synthetic tibias before and after in vitro knee surgery. Three tibias were implanted with cemented and press-fit stem augments and solely with a tibial tray (short monobloc stem) of the P.F.C. Sigma Modular Knee System. The difference between principal strains of the implanted and the intact tibia was calculated for each strain gauge position. The results demonstrated a pronounced strain-shielding effect in the proximal level, close to tibial tray with the cemented stem augment. The press-fit stem presented a minor effect of strain shielding but was more extensively throughout the stem. An increase of strains closely to the distal tip of the cemented and the press-fit stem augment was observed. This suggests for a physiological condition, a potential effect of bone resorption at the proximal region for the cemented stem augment. The localized increase of strains in stems tip can be related with the clinical finding of the pain, at the end of stem after revision TKA.  相似文献   

16.
Effect of initial interference fit on pull-out strength in cementless fixation between bovine tibia and smooth stainless steel post was investigated in this study.Compressive behavior of bovine spongious bone was studied using mechanical testing in order to evaluate the elastic-plastic properties in different regions of the proximal tibia.Friction tests were carried out in the aim to evaluate the friction behavior of the contact between bovine spongious bone and stainless steel.A cylindrical stainless steel post inserted in a pre-drilled bovine tibia with an initial interference fit was taken as an in vitro model to assess the contribution of post fixation to the initial stability of the Total Knee Arthroplasty (TKA) tibial component.Pull-out experiments were carried out for different initial interference fits.Finite Element Models (FEM) using local elastic-plastic properties of the bovine bone were developed for the analysis of the experimental ultimate pull-out force results.At the post/bone interface,Coulomb friction was considered in the FEM calculations with pressure-dependent friction coefficient.It was found that the FEM results of the ultimate force are in good agreement with the experimental results.The analysis of the FEM interfacial stresses indicates that the micro-slip initiation depends on the local bone properties.  相似文献   

17.
The purpose of this study was to determine the cause and effect relationship between tibial internal rotation and pronation of the foot during walking and heel-toe running. This would allow predictions of orthotic effectiveness in reducing knee pain related to excessive internal tibial rotation. Kinematic and force plate data were collected from twenty subjects performing ten running and ten walking trials across a force plate. Using a least-squares algorithm, attitude matrices for each segment in each frame were obtained and the angular velocity vector of the tibia was calculated. The intersegmental moment at the ankle was calculated from ground reaction force and kinematic data, and the power flow from foot to tibia associated with axial tibial rotation was calculated. In walking, all subjects exhibited a clear power flow from tibia to foot during most of the stance phase, indicating that the foot was following the body. This suggests that the use of foot orthoses to reduce knee pain associated with tibial rotation during walking will not be successful. During running, power flow was also mainly proximal to distal, but there were brief periods of opposite power flow. There was more variability between subjects during running, with five subjects having large distal to proximal power flow peaks. These observations may explain and support previous work that has found variable clinical effects of orthoses between patients.  相似文献   

18.
The use of vascularized bone grafts to reconstruct extremity and mandibular defects is now commonplace in reconstructive surgery. Fibula, scapula, iliac crest, rib, and metatarsal as well as the radial forearm osseocutaneous flaps have all been utilized for this purpose. Troublesome spiral fractures of the distal radius are the most common fractures associated with the use of the distal radius as a vascularized bone-graft donor site. This study was proposed to investigate the effect of donor-site bone loss on the strength of the radius under torsional (rotational) loading. Previous clinical series and experimental studies have not examined this aspect of distal radius loading after harvesting the bone graft. Fifty pairs of sheep tibiae were utilized in the experiment. Five pairs were used in a pilot study and 45 pairs were used in the main experiment. Five pairs of human radii were used for the control in the pilot study. The pilot study attempted to make a comparison between the human radius and the sheep tibia for experimental purposes. For the biomechanical study of donor-site defects, four study groups were examined with random assignment and matched pairs. The control group (group 1) had no alteration to the bone. Each test condition included five matched pairs of sheep tibiae. Experiment 1 compared the difference in the depth of the osteotomy defect. In doing this, one-third of the total length of the bone was removed in each of the following specimens to include (1a) 30 percent of the cross-sectional area of the total bone, (1b) 37 percent of the cross-sectional area of the total bone, and (1c) 50 percent of the cross-sectional area of the total bone. In experiment 2, the osteotomy shape was varied. Instead of the ends of the cuts being squared, the ends were beveled or rounded. Experiment 3 compared different lengths of bone removed in the osteotomy defect and included the following: In experiment 3a the diameter of the sheep tibia was measured at the incisura fibularis. This dimension was one diameter of bone, and a one-diameter length of bone was removed. In experiment 3b, a two-diameter length of bone was removed. In experiment 3c, a three-diameter length of bone was removed. In experiment 3d, a four-diameter length of bone was removed.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

19.
Bone strain is the governing stimuli for the remodeling process necessary in the maintenance of bone's structure and mechanical strength. Strain gages are the gold standard and workhorses of human bone experimental strain analysis in vivo. The objective of this systematic literature review is to provide an overview for direct in vivo human bone strain measurement studies and place the strain results within context of current theories of bone remodeling (i.e. mechanostat theory). We employed a standardized search strategy without imposing any time restriction to find English language studies indexed in PubMed and Web of Science databases that measured human bone strain in vivo. Twenty-four studies met our final inclusion criteria. Seven human bones were subjected to strain measurements in vivo including medial tibia, second metatarsal, calcaneus, proximal femur, distal radius, lamina of vertebra and dental alveolar. Peak strain magnitude recorded was 9096 με on the medial tibia during basketball rebounding and the peak strain rate magnitude was -85,500 με/s recorded at the distal radius during forward fall from standing, landing on extended hands. The tibia was the most exposed site for in vivo strain measurements due to accessibility and being a common pathologic site of stress fracture in the lower extremity. This systematic review revealed that most of the strains measured in vivo in different bones were generally within the physiological loading zone defined by the mechanostat theory, which implies stimulation of functional adaptation necessary to maintain bone mechanical integrity.  相似文献   

20.
The blood supply of the periosteum of the human tibia was investigated by anatomical dissection of 12 lower extremities which were filled with injection mass. By division of the tibia into 4 segments (proximal and distal fifths; proximal and distal diaphysis) a general supplying system of the periosteum was found. The proximal fifth of the tibial periosteum is nourished by branches of the arteriae recurrentes tibiales anterior et posterior and the aa. inferiores medialis et lateralis genus. At the proximal diaphysis (next three tenths of the tibia) periosteal branches arise from the aa. tibialis anterior and posterior, whereas the distal diaphysis is nourished exclusively by semicircular vessels of the a. tibialis anterior which twine around the bone and merge with each other at the facies medialis. Concerning the periosteal blood supply of the distal fifth of the tibia, two different types were found. In two thirds of the cases the lateral side was nourished by branches of the a. tibialis anterior, which are supported by vessels from the a. fibularis. In one third the latter branch was absent so that the rami periostales arising from the a. tibialis anterior nourished the lateral aspect of the distal tibia alone. The dorsal region was supplied in all cases by rami of the a. fibularis and a. tibialis posterior. On the medial side the periosteal nourishment is ensured only by anastomosis. Branches of the a. tibialis anterior supply the facies lateralis and facies posterior where it is supported by vessels of the a. tibialis posterior and in a minor region of rami of the a. fibularis (distal) and a. poplitea (proximal).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号