首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ultrafiltration of human plasma in combination with LC-MS/MS has been increasingly used in the quantitative analysis of the free fraction of drug candidates for PK/efficacy assessment. In addition to controlling the pre-incubation and centrifugation temperatures, some important factors that must be investigated and addressed include: (1) possible nonspecific binding, (2) possible impact of freeze/thaw cycles of plasma samples and extended storage of plasma samples at room temperature on the analyte recovery prior to ultrafiltration, and (3) identification of the appropriate assay dynamic range to avoid unnecessary dilutions. These factors were explored in the development and validation of a robust LC-MS/MS assay for the quantitative analysis of unbound vadimezan (ASA404) in human plasma. First, to mimic human physiological conditions, all plasma samples were incubated at ~37°C for a minimum of 30 min after thawing and prior to centrifugation to obtain the ultrafiltrate. Second, by passing the calibration standards and QC samples in plasma ultrafiltrate through the ultrafiltration membrane, the observed non-specific binding of the analyte due to the membrane was corrected. Third, the effects of multiple freeze/thaw cycles and/or storage at room temperature for various periods (4, 8, 16 and 24h) were evaluated to determine the impact on analyte concentrations in the ultrafiltrate from the plasma QC samples. Fourth, the appropriate dynamic range was established to accommodate the expected incurred sample free analyte concentrations. The validated assay has a dynamic range of 30.0-30,000 ng/ml for ASA404 in human plasma ultrafiltrate using a sample volume of 30 μl. Quality control pools containing the analyte were prepared at concentrations of 30.0-22,500 ng/ml to cover the assay calibration range. The intra-assay and inter-assay precision and accuracy were ≤ 15% (CV) and within ± 15% (bias) of the nominal values, respectively, for all measured QC concentrations, including the LLOQ. Freeze/thaw for up to three cycles of the plasma samples and/or the extended human plasma sample exposure to room temperature for up to 24h were confirmed to have no impact on the assay results for the free analyte. The validated method was successfully implemented to support clinical studies for the compound.  相似文献   

2.
Measurement of oxalate in human plasma ultrafiltrate by ion chromatography   总被引:2,自引:0,他引:2  
An improved ion chromatographic method for the measurement of oxalate in human plasma ultrafiltrate is described. Ultrafiltration was carried out using an appropriate device and procedure. Centrifugation of 0.5 ml heparin plasma at 4°C for 50 min yielded water-clear ultrafiltrate in amounts allowing replicate measurements of oxalate. The specificity of the method was confirmed. The recovery of oxalate added to plasma was approximately 80%, whereas dilution of plasma, and of an oxalate-containing salt solution, resulted in falsely high values; the mechanism(s) underlying this phenomenon are insufficiently understood at present. The intra-assay of the method was assessed and from replicates of a pool plasma, the inter-assay precision from ten measurements of the same plasma on different days; the observed ranges of oxalate were 1.32-1.56 (mean 1.42) and 1.42-1.64 (mean 1.53) μmol/l, respectively. In plasma ultrafiltrate of a limited number of healthy volunteers the range of oxalate was 1.81-2.50 μmol/l, thus permitting renal oxalate handling to be studied.  相似文献   

3.
Cisplatin is a cytotoxic platinum compound, used in the treatment of several solid tumors. Cisplatin and to a greater extent its hydrolysis product monohydrated cisplatin are responsible for side-effects like nephrotoxicity. A sensitive, accurate and precise method was developed to simultaneously determine cisplatin and monohydrated cisplatin in plasma. The compounds were separated by high-performance liquid chromatography and quantified by off-line furnace atomic absorption spectrophotometry. The linear ranges for cisplatin and monohydrated cisplatin in deproteinized plasma were 60-600 and 87.5-700 nM, respectively. From plasma, the mean recovery of cisplatin was 83.2% and that of monohydrated cisplatin 79.1%. The lower limits of quantification of cisplatin and monohydrated cisplatin in deproteinized plasma were 60 and 87.5 nM, respectively. Over the whole calibration range, the within- and between-day accuracy of intact cisplatin ranged from 100.7 to 111.4 and 94.8-102.0%, respectively. The within- and between-day accuracy of monohydrated cisplatin ranged from 107.1 to 113.3 and 101.4-104.9%, respectively. The within-day and between-day precision of cisplatin ranged from 3.4 to 11.5 and 7.3-10.3%, respectively. For monohydrated cisplatin, the within-day and between-day precision ranged from 3.7 to 6.2 and 5.6-7.9%, respectively. Currently, the developed assay has been implemented in pharmacokinetic studies of patients treated with cisplatin alone or in combination with other drugs.  相似文献   

4.
The immunosuppressant drug mycophenolic acid (MPA) and its major metabolite, mycophenolic acid glucuronide (MPAG), are highly bound to albumin. An HPLC-tandem-MS (HPLC/MS/MS) and an HPLC-UV assay were developed to measure free (unbound) concentrations of MPA and MPAG, respectively. Ultrafiltrate was prepared from plasma (500 microl) by ultrafiltration at 3000 x g for 20 min (20 degrees C). Both MPA and MPAG were isolated from ultrafiltrate (100 microl) by acidification and C18 solid-phase extraction. Free MPA was measured by electrospray tandem mass spectrometry using selected reactant monitoring (MPA: m/z 338.2--> 206.9) in positive ionisation mode. Chromatography was performed on a PFPP column (50 mm x 2 mm, 5 microm). Total analysis time was 7 min. The assay was linear over the range 1-200 microg/l with a limit of quantification of 1 microg/l. The inter-day accuracy and imprecision of quality controls (7.5, 40, 150 microg/l) were 94-99% and < 7%, respectively. Free MPAG was chromatographed on a C18 Nova-Pak column (150 mm x 3.9 mm, 5 microm) using a binary gradient over 20 min. The eluent was monitored at 254 nm. The assay was linear over the range 1-50 mg/l with the limit of quantification at 2.5 mg/l. The inter-day accuracy and imprecision of quality controls (5, 20, 45 mg/l) was 101-107% and < 8% (n = 4), respectively. For both methods no interfering substances were found in ultrafiltrate from patients not receiving MPA. The methods described have a suitable dynamic linear range to facilitate the investigation of free MPA and MPAG pharmacokinetics in transplant patients. Further, this is the first reported HPLC-UV method to determine free MPAG concentrations.  相似文献   

5.
Ertapenem is a new once-a-day antibiotic with excellent coverage of common community gram negative and gram positive aerobes and anaerobes. It demonstrates nonlinear protein binding in human plasma (about 94% bound). An assay for unbound drug was developed to study the pharmacokinetics of unbound ertapenem in plasma. Unbound drug is separated from plasma samples (1.0 ml) by ultrafiltration using a Centrifree((R)) centrifugal filter device. Ertapenem (vulnerable to hydrolysis of the beta-lactam moiety) is stabilized in the filtrate by adding an equal volume of 0.1 M MES buffer, pH 6.5 and then is analyzed by reversed-phase high-performance liquid chromatography (HPLC) with ultraviolet (UV) absorbance detection (300 nm). Non-specific binding to the Centrifree((R)) device is <3%. A suitable internal standard is not available. The assay is specific and linear over the concentration range of 0.25 to 100 microgram/ml in plasma filtrate. The lower limit of quantitation (LLOQ) is 0.25 microgram/ml. Intra-day precision is C.V.<10% and accuracy ranges from 97 to 101% of nominal concentration. Inter-day precision and accuracy were determined using quality control samples (QCs) prepared in plasma ultrafiltrate at 0.5, 12 and 80 microgram/ml and stored at -70 degrees C with stabilizer. Inter-day assay accuracy and precision ranged from 100 to 111% of nominal concentration and 1.8 to 5.3% C.V. (n=40), respectively. The assay has been used to analyze plasma samples from subjects receiving 500 and 2000 mg i.v. doses of ertapenem (30 min infusion).  相似文献   

6.
A reversed-phase HPLC assay has been developed to determine the concentration of the anti-metabolite 2',2'-difluorodeoxycytidine (gemcitabine, dFdC) in human plasma over the concentration range of 0.5-150 microM (0.13-39.44 microg/ml), and 2',2'-difluorodeoxyuridine (dFdU), the deaminated, inactive metabolite, over the range of 1.0-227 microM (0.26-60 microg/ml). After the addition of 20 nmol 2'-fluorodeoxycytidine (FdC) as an internal standard, 0.5-ml samples of plasma were subjected to acetonitrile precipitation, followed by analysis using a gradient reversed-phase HPLC assay with UV detection. A Phenomenex Columbus C(18) column, 5 microm, 150 x 4.6 mm, and a Waters C(18), 4 microm, Nova-Pak Sentry guard column were used to achieve separation. FdC, dFdC and dFdU were monitored at 282, 269 and 258 nm, respectively, on a Waters 996 photodiode array detector. The mobile phase, run at a total flow-rate of 1.5 ml/min, was composed of two solvents: 50 mM ammonium acetate pH 5.0 in either 2% (solvent A) or 10% methanol (solvent B, v/v); 100% solvent A was run for 17 min, followed by a linear gradient to 100% solvent B over 14 min. FdC, dFdC and dFdU were resolved from endogenous compounds and had retention times of 13.6+/-0.5, 18.1+/-1.1 and 29.0+/-0.6 min, respectively. The assay was useful in measuring the plasma levels of both analytes in samples obtained from adult cancer patients participating in a Phase I trial of gemcitabine given as either a 1- or 2-h infusion weekly for 3 of 4 weeks.  相似文献   

7.
A miniaturized temperature-programmed packed capillary liquid chromatographic method with on-column large volume injection and UV detection for the simultaneous determination of the three selective serotonin reuptake inhibitors citalopram, fluoxetine, paroxetine and their metabolites in plasma is presented. An established reversed-phase C8 solid-phase extraction method was employed, and the separation was carried out on a 3.5-microm Kromasil C18 0.32x300 mm column with temperature-programming from 35 (3 min) to 100 degrees C (10 min) at 1.3 degrees C/min. The mobile phase consisted of acetonitrile-45 mM ammonium formate (pH 4.00) (25:75, v/v). The non-eluting sample focusing solvent composition acetonitrile-45 mM ammonium formate (pH 4.00) (3:97, v/v) allowed injection of 10 microl or more of the plasma extracts. The method was validated for the concentration range 0.05-5.0 microM, and the calibration curves were linear with coefficients of correlation >0.993. The limits of quantification for the antidepressants and their metabolites ranged from 0.05 to 0.26 microM. The within and between assay precision of relative peak height were in the range 2-22 and 2-15% relative standard deviation, respectively. The within and between assay recoveries were in the 61-99 and 54-92% range for the antidepressants, respectively, and between 52-102 and 51-102% for the metabolites.  相似文献   

8.
A quantitative liquid chromatography positive ion electrospray tandem mass spectrometric method for the simultaneous determination of sulforaphane, iberin and their metabolites in human urine and plasma is described. The stability of the metabolites was determined in aqueous solution and in human plasma. Gradient liquid chromatographic separation was performed on a Zorbax SB-Aq 3.5 microm (100 x 2.1mm) column, using a mobile phase (flow rate 0.25 mL/min) consisting of ammonium acetate buffer at pH 4 and acetonitrile. Butyl thiocarbamoyl l-cysteine was used as internal standard. The assay was linear (r(2)>0.99) over the range of 0.03-300 microM in urine and 0.03-15 microM in plasma with intra- and inter-day assay precision (<10% CV) and accuracy (<20%). The lower limits of quantitation were in the range of 10-150 nmol/L. The method has been used to report, for the first time, individual quantitative measurement of each of the mercapturic acid pathway metabolites of sulforaphane and iberin in both human plasma and urine following a dietary study of broccoli consumption.  相似文献   

9.
A simple, accurate, precise, specific and reproducible high-performance liquid chromatography (HPLC) method was developed for determination of trans-polydatin, a natural strong anti-oxidative compound, in rat plasma and cell suspension. The assay procedure involved simple liquid-liquid extraction, the supernatant liquid was added an equal volume of water to avoid solvent effect. The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 303 nm. The analysis used a Hypersil ODS2 C18 column (5 microm, 4.6 mm x 250 mm) and methanol/distilled water as the mobile phase (flow rate=1 mL/min). A total analytical run was achieved within 6.0 min and calibration curve was linear over a wide concentration range of 0.25-40 microg/mL for plasma sample and 1.0-500 microM for cell suspension, the coefficients of correlation were 0.9997 and 0.9999 or better, respectively. There was 80.7+/-7.86%, 96.8+/-3.20% and 102.7+/-9.72% recovery from 0.5, 10, and 40 microg/mL plasma samples, respectively. Intra- and inter-batch accuracy and precision were acceptable for the both matrices. The RSD of intra- and inter-day assay variations were all less than 10%. Both analyte and IS were stable in the battery of stability studies, freeze-thaw cycles. The described assay method was applied to pharmacokinetic studies in rats and a human colon adenocarcinoma cell line (Caco-2) successfully. The application of the assay to determine the pharmacokinetic is described.  相似文献   

10.
A reversed-phase high-performance liquid chromatographic assay for the simultaneous determination of phenytoin and fosphenytoin, a prodrug for phenytoin, in human plasma and plasma ultrafiltrate is described. For plasma, the method involves simple extraction of drugs with diethyl ether and evaporation of solvent, followed by injection of the reconstituted sample onto a reversed-phase C18 column. Plasma ultrafiltrate is injected directly into the HPLC column. Compounds are eluted using an ion-pair mobile phase containing 20% acetonitrile. The eluent is monitored by UV absorbance at 210 nm. The fosphenytoin standard curves are linear in the concentration range 0.4 to 400 μg/ml for plasma and 0.03 to 80 μg/ml for ultrafiltrate. Phenytoin standard curves are linear from 0.08 to 40 μg/ml for plasma and from 0.02 to 5.0 μg/ml for ultrafiltrate. No interferences with the assay procedure were found in drug-free blank plasma or plasma ultrafiltrate. Relative standard deviation for replicate plasma or ultrafiltrate samples was less than 5% at concentrations above the limit of quantitation for both within- and between-run calculations.  相似文献   

11.
Paclitaxel is pharmaceutically formulated in a mixture of Cremophor EL and ethanol (1:1, v/v). The unbound fraction of the anticancer drug paclitaxel in plasma is dependent on both plasma protein binding and entrapment in Cremophor EL micelles. We have developed a simple and reproducible method for the quantification of the unbound paclitaxel fraction in human plasma. Human plasma was spiked with [3H]paclitaxel and [14C]glucose (unbound reference) and incubated at 37 degrees C for 30 min. Plasma ultrafiltrate was prepared by a micropartition system (MPS-1) and collected in a sample cup containing 100 microl of plasma to prevent the loss of paclitaxel due to adsorption. The radionuclides were separated after combustion of the biological samples using a sample oxidizer and the radioactivity was determined by liquid scintillation counting. The unbound fraction of paclitaxel was calculated by dividing the ratios of 3H and 14C in plasma ultrafiltrate and in plasma. The method was thoroughly validated using human plasma spiked with pharmacologically relevant concentrations of paclitaxel (10-1000 ng/ml) and Cremophor EL (0.25-2.0%). The method was precise, with a within-day precision ranging from 3.9 to 11.0% and a between-day precision ranging from 5.8 to 13.1%. In patient plasma with low serum albumin values containing 1% of Cremophor EL, the unbound fraction appeared to be significantly higher than that in plasma with normal albumin values. The determination of the unbound fraction of paclitaxel proved to be stable during a 10-week storage at -20 degrees C. Furthermore, the assay was applicable in patient samples. This assay can be used to determine the unbound fraction of paclitaxel in plasma. Moreover, its design should allow the determination of the unbound concentrations of other hydrophobic drugs.  相似文献   

12.
An analytical method is described for the quantification of S-nitrosoglutathione (GSNO), a potent physiological vasodilator and inhibitor of platelet aggregation, in the presence of a high excess of reduced glutathione (GSH). The method is based on the quantitative elimination of GSH by N-ethylmaleimide, the conversion of GSNO by 2-mercaptoethanol to GSH, its reaction with o-phthalaldehyde (OPA) to form a highly fluorescent and UV-absorbing tricyclic isoindole derivative, and subsequent high-performance liquid chromatographic (HPLC) separation with fluorescence and/or UV absorbance detection. The OPA derivatives of GSH and GSNO obtained by this method were found to be identical by mass spectrometry. GSH (up to 50 microM) did not interfere with the analysis of GSNO (up to 1000 nM). The limits of detection of the method for buffered aqueous solutions of GSNO were determined as 3 nM using fluorescence and 70 nM using UV absorbance detection. Isolation of GSNO by HPLC analysis (pH 7.0) of plasma ultrafiltrate samples (200 microl) prior to derivatization allows specific and artifact-free quantification of GSNO in human and rat plasma. Reduced and oxidized glutathione, nitrite, and cysteine did not interfere with the measurement of GSNO in human and rat plasma. The limit of quantitation (LOQ) of the combined method was determined as 100 nM of GSNO in human plasma ultrafiltrate using fluorescence detection. No endogenous GSNO could be detected in ultrafiltrate samples of plasma of 10 healthy humans at concentrations exceeding the LOQ of the method. After iv infusion of GSNO (125 micromol/kg body wt) in a rat for 20 min GSNO and GSH were detected in rat plasma at 60 and 130 microM, respectively. The method should be useful to investigate formation, metabolism, and reactions of GSNO in vitro and in vivo at physiologically relevant concentrations.  相似文献   

13.
The properties of membrane lipids in sensitive A(549) and resistant A(549)/DDP cells to cis-dichlorodiammine platinum[II] (cisplatin) were examined by combining different approaches. The results showed that fluorescence intensity (deltaF) of Merocyanine 540 (MC540) was 93.5 +/- 21.8 for the sensitive A(549) cells and 49.5 +/- 11.2 for the resistive A(549)/DDP cells, monitored by flow cytometry, which may indicate that membrane lipid packing of the sensitive A(549) cells were looser than that of the resistant A(549)/DDP cells. Diffusion rate of N-(7-nitro-2,1,3-benzoxadiazol-4-yl)-1,2-hexadecanoyl-Sn-glycero-3-phosphatidyl-ethanolamine (NBD-PE) was slower in A(549)/DDP cells than in A(549) cells as detected by fluorescence recovery after photobleaching (FRAP) technique. Fatty acid analysis of the membrane lipids showed 21.6, 27.0 and 31.8% increase in the amount of C(18:1), C(18:2) and C(18:3) fatty acid, respectively, in A(549) cells as compared to A(549)/DDP cells. The total amount of unsaturated fatty acids in the plasma membrane lipid is 69.13% +/- 2.2% for A(549), and 55.08% +/- 1.8% for A(549)/DDP cells, respectively. The resistance to cisplatin in A(549)/DDP cells was confirmed by the measurements of the transmembrane influx of Rhodamine-123, cisplatin or Bodipy-cisplatin by fluorescence assay and inductively coupled plasma mass spectrometry (ICP-MS). From the results described previously, it is concluded that changes in the membrane lipids "composition" cause a change in the physical state of the plasma membrane lipids and that this may be associated with the resistance of A(549)/DDP cells to cisplatin.  相似文献   

14.
A rapid and sensitive high-performance liquid chromatographic (HPLC) assay has been developed to allow determination of total (i.e. bound and unbound) and free (i.e. unbound) topotecan (TPT) in mouse plasma in the presence and absence of anti-TPT antibodies. The chromatographic analysis was carried out using reversed-phase isocratic elution with a Nova-Pak C18 column (3.9 mm x 150 mm, 4 microm) protected by a Nova-Pak C18 guard column (3.9 mm x 20 mm, 4 microm), where 10 mM KH(2)PO(4)-methanol-triethylamine (72:26:2 (v/v/v), pH 3.5) was used as the mobile phase. Topotecan was quantified with fluorescence detection using an excitation wavelength of 361 nm and an emission wavelength of 527 nm. The retention time for the internal standard, acridine, and TPT were 7.4 and 9.0 min, respectively. The lower limit of quantitation (LOQ) for TPT was determined as 0.02 ng in mouse plasma and mouse plasma ultrafiltrate, corresponding to a concentration of 1 ng/ml in 20 microl mouse plasma. The assay was shown to be linear over a concentration range of 1-500 ng/ml. The recoveries of free and total TPT from spiked mouse plasma were within 10% of theoretical values (assessed at 1, 20 and 500 ng/ml). The validated HPLC assay was applied to evaluate TPT pharmacokinetics following administration of TPT to Swiss Webster mice and to hyperimmunized and control BALB/c mice. The assay has been shown to be capable for measuring total and free TPT in mouse plasma with high sensitivity and will allow the testing of the effect of anti-TPT antibodies on the disposition of TPT.  相似文献   

15.
Terbium (Tb3+) fluorescence was used to investigate the interaction of cisplatin with GH3/B6 pituitary tumor cells. The binding of cisplatin to GH3/B6 cells quenched the fluorescence intensity of bound Tb3+. The IC50 for cisplatin inhibition of Tb3+-GH3/B6 fluorescence was determined to be 190 microM. Cisplatin was found to non-competitively inhibit the cellular binding of Tb3+, causing a dramatic decrease in the maximum number of high-affinity Tb3+ binding sites (by 33%), without markedly affecting their binding affinity. The half-life for the cellular binding of cisplatin was calculated to be 2.7 min. It was suggested that the plasma membrane of GH3/B6 cells contain a specific protein receptor for binding cisplatin.  相似文献   

16.
A high-throughput ultrafiltration method with a direct injection assay has been developed to determine unbound concentrations of a high-protein binding compound, an alpha(v)beta(3) bone integrin antagonist (I), in human plasma for a clinical pharmacokinetic study. The 96-well MultiScreen filter plate with Ultracel-PPB membrane was evaluated for the separation of unbound from protein-bound compound I by ultrafiltration. The sample preparation was automated using a Packard MultiPROBE II EX liquid handling system to transfer the plasma samples to the 96-well PPB plate for centrifugation and to prepare ultrafiltrate samples for analysis. Using on-line extraction with a column-switching setup for sample clean-up and separation, the ultrafiltrate samples were directly injected onto a reversed-phase HPLC system and analyzed using a mass spectrometer interfaced with an electrospray ionization (ESI) source in the positive ionization mode (LC/ESI-MS/MS). The performance of the ultrafiltration using Ultracel-PPB 96-well plate for unbound I analysis was evaluated and optimized with respect to sample volume, centrifugation temperature, speed and time, and the relationship of the well positions of the PPB plate versus filtrate volumes and concentrations. The assay intraday accuracy and precision were between 93.9 and 104.8 and <7.3% (CV), respectively. The linear range of the calibration curve for the assay was 0.1-500 ng/mL on a Finnigan TSQ Quantum LC/ESI-MS/MS system. Evaluation and validation of the unbound plasma assay demonstrated it to be rapid, sensitive and reproducible.  相似文献   

17.
Prekallikrein was purified from human plasma with a final yield of 76% using as the principal step adsorption to immobilized chicken antikallikrein IgY. When purified prekallikrein (3.4 microM) was incubated in the presence of beta-Factor XIIa (0.068 microM) for 5 min at 37 degrees C and pH 7.5, alpha-kallikrein was obtained. Upon prolonged incubation (0.5-28 h), the Mr 52,000 heavy chain of alpha-kallikrein was progressively cleaved, resulting in the formation of beta-kallikrein. The formation of beta-kallikrein was characterized as an autolytic process because it was prevented by specific inhibitors of kallikrein, including aprotinin and antikallikrein antibody but not by corn trypsin inhibitor, an inhibitor specific for beta-Factor XIIa.  相似文献   

18.
A simple, rapid and specific high-performance liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS) has been developed and validated for the determination of ketoconazole in human plasma. The method used diethyl ether to extract the ketoconazole and the internal standard (I.S.) R51012 from alkalinized plasma sample. The LC separation was on a C(18) column (50 x 3 mm, 5 microm) using acetonitrile-water-formic acid (75:25:1, v/v/v) mobile phase. The retention times were approximately 1.8 min for both ketoconazole and the I.S. The MS-MS detection was by monitoring 531.2-->82.1 (m/z) for ketoconazole, and 733.5-->460.2 (m/z) for the I.S. The dynamic range was from 20.0 to 10000 ng/ml based on 0.1 ml plasma, with linear correlation coefficient of > or =0.9985. The run time was 2.5 min/injection. The recoveries of ketoconazole and the I.S. were 102 and 106%, respectively. The precision and accuracy of the control samples were with the relative standard deviations (RSDs) of < or =4.4% (n=6) and the relative errors (REs) from -0.6 to 1.4% for intra-day assay, and < or =8.6% RSD (n=18) and -1.4 to 0.9% RE for inter-day assay. The partial volume tests demonstrated good dilution integrity. Three freeze-thaw cycles, keeping plasma samples at ambient for 24 h, storing extracted samples at ambient for 24 h, and storing frozen plasma samples at approximately -20 degrees C for up to 2 months did not show substantial effects.  相似文献   

19.
Carboplatin is a platinum analogue that is used in a number of chemotherapeutic regimens for solid tumors, such as lung and ovarian carcinomas. Most often characterization of carboplatin's pharmacokinetic properties is based on measurement of platinum, rather than intact carboplatin. We have developed a sensitive LC-MS method for the determination of intact carboplatin in plasma ultrafiltrate and in tumor tissue. Carboplatin was extracted from rat plasma ultrafiltrate and tumor samples using solid-phase extraction cartridges and analyzed using reversed-phase chromatography with positive electrospray ionization followed by mass spectrometric detection. Using 50 microliter of plasma ultrafiltrate or 140 microliter of tumor homogenate supernatant, the extraction afforded a recovery of 58.7 and 45.8% for plasma and tumor, respectively. The mobile phase was 5% acetonitrile in 0.5% acetic acid at 0.2 ml/min that yielded a retention time of carboplatin of 2.2 min. The method has been validated at carboplatin plasma ultrafiltrate concentrations from 0.07 to 2.5 microgram/ml, and from 0.03 to 1.3 microgram/ml in tumor homogenates. The main advantages of this method compared with earlier methods are the ability to measure intact carboplatin in a sensitive and specific manner.  相似文献   

20.
A rapid, selective and sensitive high-performance liquid chromatographic method with spectrophotometric detection was developed for the determination of clarithromycin in human plasma. Liquid-liquid extraction of clarithromycin and norverapamil (as internal standard) from plasma samples was performed with n-hexane/1-butanol (98:2, v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using a CN column (250 mm x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-50 mM aqueous sodium dihydrogen phosphate (32:68, v/v), pH 4.5. Detection was made at 205 nm and analyses were run at a flow-rate of 1.0 ml/min at 40 degrees C. The analysis time was less than 11 min. The method was specific and sensitive with a quantification limit of 31.25 ng/ml and a detection limit of 10 ng/ml in plasma. The mean absolute recovery of clarithromycin from plasma was 95.9%, while the intra- and inter-day coefficient of variation and percent error values of the assay method were all less than 9.5%. Linearity was assessed in the range of 31.25-2000 ng/ml in plasma with a correlation coefficient of greater than 0.999. The method was used to analyze several hundred human plasma samples for bioavailability studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号