首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An UV spectrophotometric method for protein determination using microplates is described. Using the SPECTRAmax PLUS reader, the UVStar 96- and 384-well microplates and a 96 or 384 parallel channel liquid handling technique, large-scale determinations can be performed with intraassay precision better than 3% CV (coefficient of variation) in the range from 1 to 8000 microg of protein/ml, measuring at 205, 215, and 280 nm and using different volume-dependent light-path lengths. Since the absorbance coefficient at 205 nm is found to be 30 ml/(mgxcm) for eight different proteins with a CV of 5.6% only with the Path Check option of the reader, protein concentration can be determined without any individual calibration. Samples in the volume range of 60-250 microl can be analyzed without time-consuming and expensive treatment and without sample loss. Using a special 96 or 384 parallel dialyzing device, low molecular weight substances which interfere with the analysis by their UV absorbance, such as buffers and detergents, can effectively be removed. Application examples for serum protein separation are also shown in the presence of the strongly UV absorbing detergent Triton X-100.  相似文献   

2.
A method based on liquid chromatography tandem mass spectrometry (LC-MSMS) applying atmospheric pressure chemical ionisation (APCI) in the positive ion mode was developed for the direct determination of nicotine, cotinine, trans-3'-hydroxycotinine, their corresponding glucuronide conjugates as well as cotinine-N-oxide, norcotinine, and nicotine-N'-oxide in the urine of smokers. The assay involves filtration of crude urine, fast liquid chromatography on a reversed-phase column and mass-specific detection using MSMS transitions. Deuterium-labeled nicotine, cotinine, and trans-3'-hydroxycotinine were used as internal standards. Glucuronides used as reference material were either chemically (cotinine-N-glucuronide) or enzymatically synthesized (nicotine-N-glucuronide and trans-3'-hydroxycotinine-O-glucuronide). Precision for the major nicotine analytes at levels observable in urine of smokers was better than 10%. Accuracy expressed in recovery rates in urine matrix for nicotine, cotinine, trans-3'-hydroxycotinine, and cotinine-N-glucuronide ranged from 87 to 113%. Quantitative results for the three glucuronides in urine samples of 15 smokers were compared to an indirect method in which the aglycons were determined with gas chromatography and nitrogen-selective detection (GC-NPD) before and after enzymatic splitting of the conjugates. Good agreement was found for cotinine-N-glucuronide (coefficient of variation, CV: 9%) and trans-3'-hydroxycotinine-O-glucuronide (CV: 20%), whereas the accordance between both methods was moderate for nicotine-N-glucuronide (CV: 33%). The described LC-MSMS method allows the simultaneous determination of nicotine and eight of its major metabolites in urine of smokers with good precision and accuracy. Since the method requires a minimum of sample clean-up and a very short time for chromatography (3 min), it is suitable for determining the nicotine dose in large-scale human biomonitoring studies.  相似文献   

3.
Due to its fundamental role in cellular energetics, metabolic regulation and cellular signalling, determination of intracellular adenosine-5'-triphosphate (ATP) is an irreplaceable tool in the characterization of cellular physiology. Classical protocols describing the measurement of ATP from cells usually suffer from the use of relatively high reaction volumes and the according use of cuvettes for ATP determination, thus making them impractical for processing high sample numbers. We therefore present two methods for the fast and reliable measurement of intracellular ATP levels of cells cultured in 96-well microplates. The procedures are compared with each other concerning detection limit, dynamic range, precision and practicability. Both methods described allow the fast and standardized measurement of intracellular ATP using the 96-well microplate format that is applicable for both, high-throughput cell culture and subsequent determination of intracellular ATP.  相似文献   

4.
A simple and rapid HPLC method that includes ultrafiltration to remove plasma and peritoneal fluid protein was developed to determine doripenem concentrations in human plasma and peritoneal fluid. Doripenem was stabilized by immediate mixing of the plasma or peritoneal fluid with 1M 3-morpholinopropanesulfonic acid buffer (pH 7.0) (1:1). Doripenem and an internal standard were detected by measuring their ultraviolet absorbance at 300 nm. The calibration curves for doripenem in human plasma and peritoneal fluid were linear from 0.05 to 100 microg/mL. For plasma, both the intra- and the interday precision were less than 3.41% (CV), and the accuracy was between 97.4 and 101.7% above 0.05 microg/mL. For peritoneal fluid, the intra- and the interday precision were less than 2.98% (CV), and the accuracy was between 94.4 and 103.9% above 0.05 microg/mL. The limit of detection was 0.02 microg/mL in both plasma and peritoneal fluid. The assay has been applied to the therapeutic drug monitoring of doripenem in both plasma and peritoneal fluid.  相似文献   

5.
研究和建立一种基于酶标仪-96孔板高通量测定虫草酸含量的检测方法,并对该方法进行性能评价。以酶标仪为检测仪器,在96孔板内按照设定反应条件微量加入样品和试剂进行显色反应,利用酶标仪测定吸光度值并计算虫草酸含量。通过检测精密度、重复性、回收率,并与分光光度计法进行比较,综合评价该方法的准确度、精确度。结果表明,测定数据具有较高的精密度(样品CM1的RSD值0.829%;样品CM2的RSD值1.772%)、重复性(标准样品B40的RSD值2.061%;样品CM2的RSD值1.599%)、回收率(平均回收率99.24%,RSD值3.666%),测定结果与分光光度法检测结果无显著差异(P>0.05)。结果表明,酶标仪微量法测定准确、重复性好,并可大大减少样品和试剂的用量,该方法方便、快捷、高效,可以替代分光光度法用于虫草酸含量的测定。  相似文献   

6.
A magnetic resonance (MR) imaging scanner operated at 0.5 T with a specially constructed receiving coil was used to measure volumes of primary spontaneous tumors in rats and guinea pigs. The coil was used to improve the signal to noise ratio (S/N) of the MR images of tumors in these small animals. The tumor volume was determined by the summation of the volume of contiguous slices or ellipsoid approximation. The accuracy of the volume measurement was better when the numerical integration was used in calculating the slice volume. The open sided saddle (OSS) coil used as the receiving coil gave better S/N than that of the standard head coil.  相似文献   

7.
A key trend in high-throughput screening is assay miniaturization to control reagent costs and increase throughput. For this purpose, liquid-handling devices are used that transfer nano-to low-microliter volumes into all currently used microtiter well plates. One drawback of many available dispenser and pipetting systems are high dead volumes. Therefore, the authors were looking for an easy and simple solution to modify their standard liquid-handling device, PerkinElmer's FlexDrop Precision IV, allowing for a dead volume reduction to receive maximum benefit from miniaturized assay formats. Internal reservoirs were developed and constructed by Schering's Technical Development Laboratory (TDL), which are directly connected to the dispenser banks of FlexDrop without tubing. Using these newly built reservoirs, the dead volume was decreased by a factor of 5 in comparison to the manufacturer's reservoirs without compromising liquid-handling parameters such as accuracy and precision. The modified system displayed a high robustness and reliability under routine high-throughput screening conditions.  相似文献   

8.
A method for the quantification of 2′-deoxy-3′-thiacytidine (lamivudine, 3-TC), which incorporated the use of 3-isobutyl-methylxanthine as internal standard (I.S.) was developed and validated in human plasma, using HPLC with UV absorbance detection. Using solid-phase extraction, 3-TC and I.S. were selectively extracted from human plasma. Subsequently, chromatographic separation was performed using a YMC phenyl column with ion-pair chromatography and detection at 270 nm. The method was validated over a concentration range of 10 to 5000 ng/ml using 0.5 ml of human plasma. The extraction recovery for both 3-TC and I.S. was greater than 95%. The determination of inter- and intra-day precision (RSD) was less than 10% at all concentration levels, while the inter- and intra-day accuracy (% difference) was less than 6%.  相似文献   

9.
The factors associated with the development, optimization, and validation of immunoassays for the detection of parasite-specific antibody in filariasis infections were investigated using the dog heartworm, Dirofilaria immitis as a model. We examined two assays, the Protein A solid-phase radioimmunoassay (SPRIA) and enzyme-linked immunosorbent assay (ELISA), for quantitation of specific antibody to the parasite in canine serum. Precision, reproducibility, and parallelism were examined using response-error relationships and precision profile analyses. A staphylococcal Protein A saturation analysis was applied to the standardization of IgG anti-parasite antibody reference sera in weight per volume units (microgram/ml). Using the mean minimal detectable dose + 3 SD and an intraassay precision profile less than 10% coefficient of variation (CV) as criteria for assay sensitivity, the SPRIA and ELISA displayed comparable positive thresholds of 1 microgram/ml IgG anti-parasite antibody/ml of serum. Both assays demonstrated good reproducibility (less than 15% interassay CV) and parallelism (less than 20% interdilutional CV) over their working ranges (SPRIA: 1-40 micrograms/ml; ELISA: 1-5 micrograms/ml). Specificity of each assay was enhanced by preadsorption of cross-reacting antibodies in canine serum (i.e., specific for Toxocara canis antigens) with solid-phase antigen prior to assay. Methods for comparing different immunoassay designs are considered in relation to the variables that influence the assays' performance characteristics.  相似文献   

10.
A gradient high-performance liquid chromatographic (HPLC) method is described for the quantification of KW-2149 and its two major metabolites in plasma. The method involves a sample clean-up by solid-phase extraction on C18 columns, separation of the respective compounds by HPLC on a YMC ODS-AQ column (5-μm particle size, 150×6 mm I.D.), using a methanol–water gradient system as an eluent, and measurement by UV absorbance detection at 375 nm. The limits of quantitation were 10 ng/ml for KW-2149 and M-16, and 15 ng/ml for M-18. Recoveries from plasma were higher than 92% on C18 extraction columns. Intra-day precision, expressed as %C.V., was between 1.4 and 6.5%. Intra-day accuracy ranged from 94 to 107%. Precision and accuracy of variability of inter-assays increased somewhat; however, were still within acceptable ranges. The ability of the method to quantify KW-2149 and two major metabolites simultaneously, with precision, accuracy and sensitivity, make it useful in monitoring the fate of this new mitomycin in cancer patients.  相似文献   

11.
分光光度法测定金荞麦(-)-表儿茶素含量的方法研究   总被引:1,自引:0,他引:1  
为建立香荚兰素-盐酸分光光度法对表儿茶素含量的测定方法,实验分别以乙醇和水作溶剂,在34.79~208.74μg范围内取样置50 mL容量瓶测定,结果发现:①以乙醇作溶剂时,测定波长为508 nm,1%香荚兰浓盐酸添加量应超过40mL(CV≤1.86%),测定时间以40 min后为宜(CV≤2.65%),标准曲线线性关系(R=0.999 3)与精确度(CV=2.66%)、准确度(P0.05)良好。②以水作溶剂时,测定波长为504 nm,显色反应不稳定,标准曲线线性关系(R=0.988 1)也较一般。③采用乙醇作溶剂时,测得金荞麦块根中(-)-表儿茶素类物质含量占干物质的2.22%(CV≤3.90%),该法操作简便,灵敏度高,重现性好。  相似文献   

12.
In the blood of normal subjects, the volumes of single erythrocytes are distributed with a coefficient of variation (CV) of 10.8 +/- 1.8%; while in hemoglobinopathies, CV increases proportionately to the degree of anemia produced. Using single cell Soret-band hemoglobinometry and focused-aperture impedance counting, we compared the distribution of red cell volume, area, hemoglobin content, and hemoglobin concentration in normals and subjects with anemic disorders. The CV, nondiscrete heterogeneity, is first, a general characteristic of biologic measurement, second, a sensitive indicator of abnormality of erythropoiesis, and third, consistently less for hemoglobin concentration than for volume, area, or hemoglobin content of the same cells.  相似文献   

13.
Brown PH  Balbo A  Zhao H  Ebel C  Schuck P 《PloS one》2011,6(10):e26221
The partial-specific volume of proteins is an important thermodynamic parameter required for the interpretation of data in several biophysical disciplines. Building on recent advances in the use of density variation sedimentation velocity analytical ultracentrifugation for the determination of macromolecular partial-specific volumes, we have explored a direct global modeling approach describing the sedimentation boundaries in different solvents with a joint differential sedimentation coefficient distribution. This takes full advantage of the influence of different macromolecular buoyancy on both the spread and the velocity of the sedimentation boundary. It should lend itself well to the study of interacting macromolecules and/or heterogeneous samples in microgram quantities. Model applications to three protein samples studied in either H(2)O, or isotopically enriched H(2) (18)O mixtures, indicate that partial-specific volumes can be determined with a statistical precision of better than 0.5%, provided signal/noise ratios of 50-100 can be achieved in the measurement of the macromolecular sedimentation velocity profiles. The approach is implemented in the global modeling software SEDPHAT.  相似文献   

14.
Methionine is an important amino acid involved in protein synthesis and transmethylation reactions. It is also the precursor of homocysteine and cysteine, two important risk factors for cardiovascular diseases. As homocysteine research has gained impulsion, the evaluation of plasma methionine concentrations has acquired importance. Methionine measurement generally has been performed by HPLC after o-phthalaldehyde derivatization. Its separation from other amino acids is time-consuming. We set up a new specific capillary electrophoresis method in which analyte derivatization was avoided by sample concentration before analysis. Methionine was detected by UV absorbance at 204 nm with a detection limit of 0.5 micromol/L. By a capillary with an effective length of 50 cm filled with 125 mmol/L Tris phosphate buffer at pH 2.3, the separation occurred in less than 14 min. Precision tests indicated a good test repeatability for both migration times (coefficient of variation [CV]<0.3%) and areas (CV<2.0%). Moreover, a good reproducibility of intraassay and interassay tests was obtained (CV<2.9% and CV<3.5%, respectively). The Passing-Bablok regression and the Bland-Altman test for methods comparison suggest that the data obtained by our method and by a reference HPLC assay are similar. Assay performance was evaluated measuring methionine concentrations in retinal venous occlusive disease.  相似文献   

15.
Differences in breast volume and contour are subjectively estimated by surgeons. 3D surface imaging using 3D scanners provides objective breast volume quantification, but precision and accuracy of the method requires verification. Breast volumes of five test individuals were assessed using a 3D surface scanner. Magnetic resonance imaging (MRI) reference volumes were obtained to verify and compare the 3D scan measurements. The anatomical thorax wall curvature was segmented using MRI data and compared to the interpolated curvature of the posterior breast volume delimitation of 3D scan data. MRI showed higher measurement precision, mean deviation (expressed as percentage of volume) of 1.10+/-0.34% compared to 1.63+/-0.53% for the 3D scanner. Mean MRI [right (left) breasts: 638 (629)+/-143 (138) cc] and 3D scan [right (left) breasts: 493 (497)+/-112 (116) cc] breast volumes significantly correlated [right (left) breasts: r=0.982 (0.977), p=0.003 (0.004)]. The posterior thorax wall of the 3D scan model showed high agreement with the MRI thorax wall curvature [mean positive (negative) deviation: 0.33 (-0.17)+/-0.37 cm]. High correspondence and correlation of 3D scan data with MRI-based verifications support 3D surface imaging as sufficiently precise and accurate for breast volume measurements.  相似文献   

16.
A sensitive and specific method for the simultaneous determination of the unchanged drug (solifenacin) and its major metabolite (M1, 4S-hydroxy solifenacin) in rat plasma was developed and validated. Both solifenacin and M1 were extracted from rat plasma by a two-step liquid-liquid extraction and analyzed by semi-micro HPLC with UV detection at an absorbance wavelength of 220 nm. The chromatographic separations were performed on a TSKgel ODS-80Ts (5 microm, 150 mmx2.0 mm i.d.) reversed-phase column with a mobile phase of 0.1 M phosphate buffer (pH 3.0):acetonitrile (71:29, v/v). The intra-day precision (expressed as coefficient of variation, CV) ranged from 0.4% to 1.7%, and the accuracy (expressed as relative error, RE) ranged from -5.2% to 2.0% for solifenacin. The corresponding precision ranged from 1.3% to 3.2%, and accuracy ranged from -4.0% to 8.6% for M1. The lower limit of quantitation for both solifenacin and M1 was 2 ng/ml when 1 ml of plasma was used. No endogenous interference was observed in rat plasma.  相似文献   

17.
The assumptions and performances of three light microscope techniques for measuring the amount of detritus in the diets of omnivorous fish were compared: area estimation, volume estimation with subsequent estimation of weight, and weight difference determination. Accuracy of the area method depends on the improbable assumption that the volume or weight of detritus particles in the diet is directly proportional to particle area. Accuracy of the difference determination is limited by the accumulation of measurement errors associated with each component of the calculation. Direct estimation of volume with subsequent conversion to ash free dry weight requires the fewest assumptions and offers greatest accuracy. Precision was greatest for the volume estimation technique and lowest for the difference determination. Time required per sample can be substantially reduced by using a digitizer for measurement and a microcomputer for calculations.  相似文献   

18.
A method for the simultaneous determination of +S and -R arotinolol in serum by micellar electrokinetic capillary chromatography is described. Stereoselective resolution of the arotinolol enantiomers was achieved using 5 mM sodium taurocholate in 10 mM sodium dihydrogen phosphate buffer of pH 2.5. A 72-cm uncoated fused-silica capillary at a constant voltage of 15 kV was used for the analysis. The analytes of interest were extracted from serum using solid phase extraction. An octadecyl cartridge gave good recoveries in excess of 87% for both +S and -R arotinolol without any interference. The calibration curves were linear over the range of 50-500 ng ml(-1) with +S propranolol as the internal standard and the coefficient of determination was greater than 0.999 (n = 3). The limit of quantitation was 50 ng ml(-1) for each enantiomer and the detection limit using 1 ml serum and a UV detection set et 220 nm was 25 ng ml(-1) (S/N = 2). Precision and accuracy of the method were in the range 0.8-2.7% and 1.2-6.4%, respectively, for +S arotinolol and 1.1-3.9% and 2.2-6.5%, respectively, for -R arotinolol.  相似文献   

19.
High‐throughput platforms for microalgae screening are not yet commercially available. In this study, the feasibility of 96‐well microplates was analyzed for microalgae research. Equivalence among wells, as culture microreactors, was investigated in controlled high CO2 conditions. Specific growth rates of two microalgae species, Scenedesmus sp. UTEX1589 and an environmental isolate, were significantly higher in border wells than in internal positions. Furthermore, growth rate gradients analyzed as contours throughout the platform were observed for Scenedesmus sp. However, the output variable exhibited high precision associated with a low coefficient of variation (CV), between 6.8 and 7.8%. In a demonstrative experiment to determine the effect of culture media dilution on six microalgae species, treatments were randomized in the central subset of a microplate. Results were consistent and statistically sound (CV 9.4–12.9%), and showed that microalgae species could grow with no detrimental effect in 50% (v/v) dilution of the culture medium. Provided border wells exclusion and a randomized design, 96‐well microplates are a practical and statistical robust platform for microalgae research. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 29:638–644, 2013  相似文献   

20.
A method for the determination of N-glucuronidation of nicotine and cotinine in human liver microsomes by high-performance liquid chromatography was developed. Nicotine or cotinine was incubated with human liver microsomes and UDP-glucuronic acid in a 200-microl incubation mixture. The nicotine N-glucuronide (Nic-glu) and cotinine N-glucuronide (Cot-glu) formed were analyzed by ion-pair chromatography with a C-18 column. The sensitivity of quantification at 260 nm absorption was improved by using a noise-base clean Uni-3, and the limit of quantification was 10 pmol/200 microl mixture for both Nic-glu and Cot-glu. Linear standard curves were obtained within the concentration ranges 25-1000 pmol/200 microl mixture for Nic-glu and 100-5000 pmol/200 microl mixture for Cot-glu. The intraassay precision and accuracy were < or =11.1% coefficient of variation (CV) and 97.5-106.6% for Nic-glu and < or =4.6% CV and 96.7-100.4% for Cot-glu. The interassay precision and accuracy were < or =7.2% CV and 98.2-106.1% for Nic-glu and < or =4.6% CV and 96.8-99.3% for Cot-glu. This is the first report of the in vitro determination of Nic-glu and Cot-glu in human liver microsomes. Furthermore, this highly sensitive HPLC method can be used for the determination of Nic-glu and Cot-glu in biological specimens in vivo.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号