首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Two experiments were conducted to determine whether cannulation of the jugular vein in gilts alters serum concentrations of LH, FSH, prolactin (PRL) or cortisol (C). In Experiment 1, 12 crossbred prepubertal gilts weighing 95 +/- 1.3 kg were immobilized by snaring, and tygon tubing was threaded into the anterior vena cava through a 12-gauge needle inserted into the jugular vein. Five hours later, blood samples were drawn at 20-min intervals for 4 h (Day 0). Samples were also drawn at 20-min intervals for 4-h periods 24 h (Day 1) and 48 h (Day 2) after cannulation. Serum concentrations of LH were similar (P=0.26) among Day 0 (0.40 ng/ml), Day 1 (0.39 ng/ml) and Day 2 (0.34 ng/ml). Serum PRL was similar (P=0.07) among Day 0 (4.10 ng/ml), Day 1 (3.87 ng/ml) and Day 2 (3.43 ng/ml). Serum concentrations of C were greater (P < 0.001) on Day 0 (8.32 ng/ml) than Day 1 (4.48 ng/ml) or Day 2 (3.54 ng/ml). In Experiment 2, cannulas were placed in 29 prepubertal gilts. Two days after initial cannulation, six blood samples were drawn at 20-min intervals. Gilts were then immobilized by snaring, and a second cannulae was inserted into the contralateral vein. Five blood samples were taken at 2-min intervals during the second cannulation and then six samples were drawn at 20-min intervals. Serum LH and FSH were not altered by cannulation or elevated during the subsequent 2-h sampling period (P>0.05). In contrast, serum concentrations of PRL rose slowly (P<0.05) during cannulation and remained elevated for 60 min before returning to baseline. Serum concentrations of C rose within 6 min of cannulation, remained elevated for 30 min, and then declined over the next 90 min. From these two experiments, it appears that secretory patterns of LH and FSH can be accurately assessed immediately after cannulation in prepubertal gilts. Measurements of serum PRL and C that reflect nonstressed conditions, however, cannot be obtained until at least 2 h or 1 d after cannulation, respectively.  相似文献   

2.
A rapid and non-surgical method for jugular catheterization in pigs was set up in 30 piglets of 6.2 kg, 23 pigs of 46 kg and 84 kg and two lactating multiparous sows. The animal was restrained on a V-shaped table (piglets) or with a rope around the mandible (slaughter pigs and sows). The vein was located with the Vacutainer system and a wire guide was inserted into the Vacutainer needle up to the vein lumen. When the needle was removed, the catheter was inserted over the wire guide and advanced until it penetrated the skin and thereafter, the vein wall. The catheter was fixed outside by a large tape and coiled inside a patch just behind the ears. The technique utilizes readily available material and is no more risky for the animal than a single blood sampling. Moreover, it can be performed within 15 to 20 min (including animal restraint) within pens. This new approach might have important implications not only for research purposes by facilitating repeated blood samplings but also for projects which require a rapid and easy method for testing of any kind of pharmaceutical or other type of products under husbandry conditions.  相似文献   

3.
A rapid, simplified technique of intravenous catheterization of the unanesthetized rat was developed for continuous infusion. A 19-gauge thin-walled needle was inserted percutaneously into the dilated tail vein, and polyethylene tubing was advanced through the needle into the vein. The catheter was protected by wire mesh electrical sheathing taped securely to the tail. This approach eliminated the need for anesthesia and surgery which were traumatic to the animal and time consuming for the investigator. This method was used successfully in 32 rats given continous infusion for up to 5 days.  相似文献   

4.
Long-term blood sampling technique in the marmoset   总被引:1,自引:0,他引:1  
A simple and reliable method for long-term blood sampling from the restrained marmoset is described. Cannulae were chronically inserted into the internal jugular vein, exteriorized and housed in a backpack system. The cannulae remained patent for 1-7 months. This system allows for rapid collection of blood samples and hence detailed analysis of circulating hormone levels.  相似文献   

5.
Long-term blood-sampling technique in piglets   总被引:1,自引:0,他引:1  
A technique to enable long-term blood sampling from piglets aged 2-3 months is described. Piglets were housed individually in expandable cages and a heparinized polyurethane catheter was inserted into the external jugular vein. A technique was used which prevented the catheter from pulling out of the vein with growth of the animals. Blood samples could be obtained for more than 1 month, and levels of cortisol, glucose, white blood cell count, haematocrit, rectal temperature and heart rate were compared for samples obtained from simulated conventional venopunctures and from the cannula using this technique. It was shown that restraint and needle pricks raised these levels considerably.  相似文献   

6.
A technique for long-term infusion into the inferior mesenteric artery was developed which allows simple and reliable regional infusion into the colorectal segment of unrestrained rats. The cannulation system consists of an injection port 'In Stoppers' as a flow swivel, connected to an injection needle, which is inserted into a polyethylene tube protected by a steel spiral. During infusion the animals are free to move in the cage with access to food and water ad libitum. The method is suitable for regional chemotherapy as well as for studies of colorectal tumours in rats. In this study 73% of the cannulae remained functional for continuous infusion over a 15 day period.  相似文献   

7.
Reliable short-term blood access in conscious swine was provided by implanting multiple silastic catheters. Catheters were inserted into the aorta, hepatic vein, portal vein, and inferior vena cava through a midline laparotomy incision. Multiple catheters also were placed into the external jugular vein through a separate cervical incision. Catheter patency rates for blood withdrawal on the sixth post-operative day were: arterial 100%, hepatic 91%, portal 86%, inferior vena cava 71%. No animal had major wound or catheter infection on the seventh post-operative day. The methods described allow metabolic studies, including measurements of splanchnic blood flow, to be carried out either acutely or for up to at least 7 days post-operatively.  相似文献   

8.
The object of this investigation was to study the feasibility of using a “Zyklomat roller peristaltic pump” for pulsatile administration of gonadotropin releasing hormone (Gn-RH) in primiparous lactating sows. Four primiparous sows were used. The pump catheter was inserted into a jugular vein on day 8 or day 22 of lactation. The pump delivered a 1 min Gn-RH pulse of 10 μg every 89 min for 7 days. The pump worked without any complication or detrimental effect on the sows throughout the experimental period. Two sows showed standing oestrus during lactation and one of them ovulated. It can be concluded that the “Zyklomat” pump can be used for pulsatile infusion of Gn-RH in lactating sows.  相似文献   

9.
Tsai TH  Huang CT  Shum AY  Chen CF 《Life sciences》1999,65(16):1647-1655
Biliary excretion and intestinal reabsorption in enterohepatic circulation play major dispositional roles for some drugs. To circumvent multiple blood sampling and interruption of enterohepatic circulation in conventional biliary cannulation, the present study utilized the minimally invasive sampling technique of microdialysis in pharmacokinetics and biliary excretion studies. Microdialysis probes were inserted into the jugular vein and bile duct in the anesthetized rat for simultaneous and continuous sampling following intravenous administration of esculetin, a bioactive coumarin derivative. Placements of the microdialysis probes were designed to minimize obstruction to normal flows of the body fluids. Separation and quantitation of esculetin in the dialysates were achieved using high performance liquid chromatography (HPLC) coupled to UV detection. The results indicated higher drug concentrations in the bile than in the blood, suggesting active biliary excretion. The study also provided an example of successful application of in vivo microdialysis as an interesting and feasible alternative for pharmacokinetics and biliary drug excretion studies.  相似文献   

10.
Cell delivery via the retrograde coronary route boasts less vessel embolism, myocardial injury, and arrhythmogenicity when compared with those via antegrade coronary administration or myocardial injection. However, conventional insertion into the coronary sinus and consequent bleeding complication prevent its application in small animals. To overcome the complication of bleeding, we described a modified coronary retroinfusion technique via the jugular vein route in rats with myocardial infarction (MI). A flexible wire with a bent end was inserted into the left internal jugular vein and advanced slowly along the left superior vena cava. Under direct vision, the wire was run into the left cardiac vein by rotating the wire and changing the position of its tip. A fine tube was then advanced along the wire to the left cardiac vein. This modified technique showed less lethal hemorrhage than the conventional technique. Retroinfusion via transjugular catheter enabled efficient fluid or cell dissemination to the majority areas of the free wall of the left ventricle, covering the infarcted anterior wall. In conclusion, transjugular cardiac vein catheterization may make retrocoronary infusion a more safe and practical route for delivering cell, drug, and gene therapy into the infarcted myocardium of rats.  相似文献   

11.
We have developed and validated a method that allows serial drawing of blood samples in freely moving mice using a cannula that is inserted via the jugular vein into the right atrium of the heart. The cannula was tunnelled subcutaneously to the head of the animal and attached to the skin by sutures, together with a metal spring, which was covered with PVC tubing for protection of the outer part of the cannula. Samples of blood up to 250 micro l could be taken at serial time points. The blood volume in the circulation was maintained by replacement with an equal volume of blood obtained from donor animals. The applicability of this method of blood sampling for pharmacokinetic purposes was validated by comparing plasma concentrations-time curves in six cannulated animals after receiving an intravenous bolus dose of 10 mg/kg of the anti-cancer agent docetaxel versus the results in plasma samples obtained by cardiac puncture of non-cannulated mice. The presented method may lead to improved pharmacokinetic data produced from a reduced number of mice.  相似文献   

12.
In this paper the authors describe the surgical procedure to prepare rabbits for haemoperfusion experiments. The carotid artery and jugular vein are cannulated and a simple shunt device inserted to maintain patency of the vessels over a period of time. The cannulas and shunt remain patent and free of infection for some months. Specially designed outflow and inflow extracorporeal tubing sets minimize blood volume outside the body of the rabbit. The authors also illustrate the efficacy of this system in haemoperfusion trials to remove specific antibodies. Recently a system was described to remove mercury from the bloodstream of poisoned animals. The rabbit is a useful experimental animal for this type of haemoperfusion trial.  相似文献   

13.
The accuracy of real-time, B-mode ultrasonography was assessed in the visualization and placement of the cannula tip, cranial to the entrance of the ovarian veins as they enter the caudal vena cava of the bovine. A cannula containing a wire guide was introduced into the coccygeal vein via a 14-gauge needle, and was then directed cranially into the caudal vena cava. Once the caudal vena cava was successfully cannulated (7 of 14 cows), ultrasonography allowed for the visualization of the cannula in 7 out of 7 cows. The tip of the cannula was successfully placed cranial to the entrance of the ovarian effuent into the vena cava in 6 of these 7 animals using ultrasound guidance. This was confirmed using progesterone or prostaglandin F(2alpha) radioimmunoassay (RIA). The primary limitation to this technique was the initial catherization of the coccygeal vein which was not achieved in 7 of 14 cows attempted in this study. Successful cannulation was limited to large framed Holstein cows that had at least one calf. Results from this study indicate that real-time, B-mode, ultrasonography is an effective tool for the visualization and accurate placement of the cannula tip within the caudal vena cava. This finding could have implications for research in ovarian hormonal physiology in the cyclic, postpartum or anestrous cow.  相似文献   

14.
We devised a method for the atraumatic repeated collection of cerebrospinal fluid samples from conscious swine and sheep. Indwelling needles, with injection caps, were secured intracisternally and protected with plastic "crowns" attached to their skulls. The crowns permitted the animals freer movement with minimal risk of damage to the needles. With sheep, cerebrospinal fluid was withdrawn directly by puncturing the self-sealing injection caps attached to the hubs of the fixed needles. With the pigs, which are less amenable to handling, lengths of sterile polyethylene tubing inserted into the fixed needles enable collection without continuously disturbing the pigs. Serial samples were withdrawn from sheep (.10 to .30 ml) for up to 3 weeks with no problems, and from pigs (.05 to .15 ml) for 8 to 12 days, until the cannulae failed.  相似文献   

15.
We describe a procedure to secure a jugular vein catheter system at the dorsal nape of the neck in the hamster. An 8-cm piece of silicone tubing is connected with a 2.6 cm L-shaped metal tubing which is embedded in prosthetic material. The prosthetic material is placed underneath the neck skin of the hamster and keeps the metal end of the catheter system in a sturdy, upright position.  相似文献   

16.
Chronic double lumen intravenous cannulation was performed on the rat. The cannulation system consisted of a pulley assembly, protective tube, mounting post, and a double lumen cannula. Using a double lumen expanded catheter, a two-channel connection was made with the rat's vascular system through a single entry into the external jugular vein. The cannulation system permitted free animal movement in a large cage and simultaneous measurement of behavioral and physiologic variables. The procedure minimized stress and provided a simple alternative to other systems using two cannulas.  相似文献   

17.
Objectives To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation.Data sources 15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature.Design Systematic review and meta-analysis of randomised controlled trials.Populations Patients scheduled for central venous access.Intervention reviewed Guidance using real time two dimensional ultrasonography or Doppler needles and probes compared with the anatomical landmark method of cannulation.Data extraction Risk of failed catheter placement (primary outcome), risk of complications from placement, risk of failure on first attempt at placement, number of attempts to successful catheterisation, and time (seconds) to successful catheterisation.Data synthesis 18 trials (1646 participants) were identified. Compared with the landmark method, real time two dimensional ultrasound guidance for cannulating the internal jugular vein in adults was associated with a significantly lower failure rate both overall (relative risk 0.14, 95% confidence interval 0.06 to 0.33) and on the first attempt (0.59, 0.39 to 0.88). Limited evidence favoured two dimensional ultrasound guidance for subclavian vein and femoral vein procedures in adults (0.14, 0.04 to 0.57 and 0.29, 0.07 to 1.21, respectively). Three studies in infants confirmed a higher success rate with two dimensional ultrasonography for internal jugular procedures (0.15, 0.03 to 0.64). Doppler guided cannulation of the internal jugular vein in adults was more successful than the landmark method (0.39, 0.17 to 0.92), but the landmark method was more successful for subclavian vein procedures (1.48, 1.03 to 2.14). No significant difference was found between these techniques for cannulation of the internal jugular vein in infants. An indirect comparison of relative risks suggested that two dimensional ultrasonography would be more successful than Doppler guidance for subclavian vein procedures in adults (0.09, 0.02 to 0.38).Conclusions Evidence supports the use of two dimensional ultrasonography for central venous cannulation.  相似文献   

18.
Gastal EL  Kot K  Ginther OJ 《Theriogenology》1995,44(7):1027-1037
A technique for intrafollicular treatment with a transvaginal ultrasound-guided injection needle was developed using equine chorionic gonadotropin (eCG) as the test substance. An injection was made into one growing follicle of a wave when the follicles were 20 to 23 mm. The treated follicles were injected with 1000 iu of eCG in 0.2 ml saline solution and control follicles were injected with 0.2 ml of the saline vehicle (10 mares per group, 1 follicle per mare). The injection system used an inner 25-gauge needle and an outer 20-gauge needle inserted together through the needle-guide channel of a linear-array trans vaginal transducer. The outer needle was pushed through the vaginal wall and the inner needle was then advanced into the follicle during monitoring on the ultrasound screen. The turbulence in the follicular fluid associated with injection was observable on the screen. Seven follicles were successfully injected in each group. The follicular fluid in the control follicles remained anechoic until the follicle was no longer identifiable or ovulated. All 7 follicles in the eCG group showed ultrasonic indications of luteinization, based on the formation of an echogenic, thickened wall or area. Five of the 7 developed a central area that had the ultrasonic appearance of a blood clot similar to the appearance of a corpus hemorrhagicum. Ovulation was not detected in any of the eCG-treated follicles. The maximum post-treatment diameter of follicles was greater (P < 0.05) for the eCG group (32.7 +/- 3.8 mm) than for the control group (23.4 +/- 1.8 mm). The mean diameter for the first 5 days post-treatment (before the occurrence of an ovulation in any mare) was also greater (P < 0.002) in the eCG group (21.6 +/- 0.8 mm vs 19.6 +/- 0.8 mm). Results indicated that this novel research approach is practical and has potential for studies on folliculogenesis. The technique provides a research model between the extremes of an in vitro culture system and treatment of the whole animal.  相似文献   

19.
Eighty-six adult, cyclic, anestrous and postpartum Ile-de-France ewes were placed under general anaesthesia. A catheter was inserted in the utero-ovarian vein (u.o.v.) of one or both ovaries in each ewe. The animals were kept unrestrained in pens and allowed to experience normal maternal behaviour, including suckling. Oestrus was detected with rams. Out of 167 catheters inserted, 70.7% allowed repetitive blood collection, 24.0% were obstructed for short periods and 5.4% remained completly blocked. Oestradiol- 17beta was assayed without extraction from the u.o.v. plasma samples. From these results, we conclude that this technique is suitable for investigating the mechanisms involved in the recovery of cyclical ovarian activity after parturition, particularly because the follicular response to endogenous gonadotropins can be assessed. This is not possible when plasma samples are obtained from a jugular vein.  相似文献   

20.
Current methods utilized for serial blood collection in the young pig are limited due to the stress and/or discomfort to which the pig is exposed. Thus, we have developed a non-surgical, minimally invasive cannulation technique which allows jugular vein catheter placement in the young pig without causing extended discomfort or stress. The procedure described is rapid (approximately 8 min/pig) and relatively simple, requiring only minimal anaesthesia for immobilization of the pig during the procedure. Routinely, 2-week-old piglets are standing in their pens within 15-20 min from initiation of the procedure. Piglets recover rapidly from the procedure and display no clinical indications of pain or discomfort. Serum concentrations of cortisol, a standard indicator of stress and/or discomfort, are asymptomatic within 2 h of completing the procedure (k = 26.14+/-3.03 ng/ml). Stress is limited to the initial immobilization of the piglets. With this technique of cannulation, we routinely maintain catheter patency for 2 days, and often for as long as 5 days.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号