首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A selective semi-automated solid-phase extraction (SPE) of the non-steroidal anti-inflammatory drugs diclofenac sodium, indomethacin and phenylbutazone from urine prior to high-performance liquid chromatography was investigated. The drugs were recovered from urine buffered at pH 5.0 using C18 Bond-Elut cartridges as solid sorbent material and mixtures of methanol–aqueous buffer or acetonitrile–aqueous buffer as washing and elution solvents. The extracts were chromatographed on a reversed-phase ODS column using 10 mM acetate buffer (pH 4.0)–acetonitrile (58:42, v/v) as the mobile phase, and the effluent from the column was monitored at 210 nm with ultraviolet detection. Absolute recoveries of the anti-inflammatory drugs within the range 0.02–1.0 μg/ml were about 85% for diclofenac and indomethacin, and 50% for phenylbutazone without any interference from endogenous compounds of the urine. The within-day and between-day repeatabilities were in all cases less than 5% and 10%, respectively. Limits of detection were 0.007 μg/ml for diclofenac sodium and indomethacin and 0.035 μg/ml for phenylbutazone, whereas limits of quantitation were 0.02 μg/ml for diclofenac and indomethacin and 0.1 μg/ml for phenylbutazone.  相似文献   

2.
A high-performance liquid chromatographic (HPLC) assay has been developed for the determination of the antifungal drug fluconazole in saliva and plasma of patients infected with the human immunodeficiency virus (HIV). Samples can be heated at 60°C for 30 min to inactivate the virus without loss of the analyte. The sample pretreatment involves a liquid-liquid extraction with chloroform-1-propanol (4:1, v/v). The chromatographic analysis is performed on a Lichrosorb RP-18 (5 μm) column by isocratic elution with a mobile phase of 0.01 M acetate buffer (pH 5.0)-methanol (70:30, v/v) and ultraviolet (UV) detection at 261 nm. The lower limit of is 100 ng/ml in plasma (using 500-μl samples) and 1 μg/ml in saliva (using 250-μl samples) and the method is linear up to 100 μg/ml in plasma and saliva. At a concentration of 5 μg/ml the within-day and between-day precision in plasma are 7.1 and 5.7%, respectively. In saliva the within-day and between-day precision is 10.8% (at 5 μg/ml). The methodology is now being used in pharmacokinetic studies in HIV-infected patients in our hospital.  相似文献   

3.
A system of an automatic sample preparation procedure followed by on-line injection of the sample extract into a gas chromatograph-mass spectrometer (GC–MS) was developed for the simultaneous analysis of seven barbiturates in human serum. A sample clean-up was performed by a solid-phase extraction (SPE) on a C18 disposable cartridge. A SPE cartridge was preconditioned with methanol and 0.1 M phosphate buffer. After loading 1.5 ml of a diluted serum sample into the SPE cartridge, the cartridge was washed with 2.5 ml of methanol–water (1:9, v/v). Barbiturates were eluted with 1.0 ml of chloroform–isopropanol (3:1, v/v) from the cartridge. The eluate (1 μl) was injected into the GC–MS. The calibration curves, using an internal standard method, demonstrated a good linearity throughout the concentration range from 0.1 to 10 μg ml−1 for all barbiturates extracted. The proposed method was applied to 27 clinical serum samples from three patients who were administrated secobarbital.  相似文献   

4.
An isocratic high-performance liquid chromatographic method has been developed and validated for the quantitative determination of paclitaxel (Taxol®), a novel antimitotic, anticancer agent, in human plasma. The analysis required 0.5 ml of plasma, and was accomplished by detection of the UV absorbance of paclitaxel at 227 nm following extraction and concentration. The method involved extraction of paclitaxel from plasma, buffered with 0.5 ml of 0.2 M ammonium acetate (pH 5.0), onto 1-ml cyano Bond Elut columns. The eluent was evaporated under nitrogen and low heat, and reconstituted with the mobile phase, acetonitrile-methanol-water (4:1:5, v/v/v) containing 0.01 M ammonium acetate (pH 5.0). The samples were chromatographed on a reversed-phase octyl 5 μm column. The retention time of paclitaxel was 10 min. The validated quantitation range of the method was 10–1000 ng/ml (0.012–1.17 μM) of paclitaxel in plasma. Standard curve correlation coefficients of 0.995 or greater were obtained during validation experiments and analysis of clinical study samples. The observed recovery for paclitaxel was 83%. Epitaxol, a biologically active stereoisomer, and baccatin III, a degradation product, were also chromatographically separated from taxol by this assay. The method was applied to samples from a clinical study of paclitaxel in cancer patients, providing a pharmacokinetic profiling of paclitaxel.  相似文献   

5.
This report describes a rapid, simple and sensitive isocratic high-performance liquid chromatography with diode array UV detection for micro-sample analysis of paclitaxel in mouse plasma. The analysis utilized a Capcell-pak octadecyl analytical column and a mobile phase consisting of acetonitrile–0.1% phosphoric acid in deionized water (55:45, v/v). Paclitaxel and n-hexyl p-hydroxybenzoic acid (internal standard) were extracted from plasma by one-step extraction with tert.-butyl methyl ether. Peak purity was determined over a UV wavelength range of 200 to 400 nm. Paclitaxel and the internal standard were eluted at 3.4 min and 5.4 min, respectively, at a mobile phase flow-rate of 1.3 ml/min. No interfering peaks were observed and the total run time was 10 min. The standard curve was linear (r=0.9999) over the concentration range of 0.010–500 μg/ml. The extraction recovery was >90% for both paclitaxel and n-hexyl p-hydroxybenzoic acid. The intra- and inter-day assay variabilities of paclitaxel ranged from 0.4 to 2.2% and 0.6 to 7.8%, respectively. The LOD and LOQ were 5 and 10 ng/ml, respectively, for paclitaxel using a plasma sample volume of 100 μl. This highly sensitive and simple assay method was successfully applied to a pharmacokinetic study after i.v. administration of paclitaxel 20 mg/kg to mice.  相似文献   

6.
The pharmacokinetic studies of fenofibrate require a rapid, selective and robust method to allow the determination of fenofibric acid, its active metabolite, in different biological matrixes (such as plasma, serum or urine). A new fully automated method for the determination of fenofibric acid in plasma has been developed, which involves the solid-phase extraction (SPE) of the analyte from plasma on disposable extraction cartridges (DECs) and reversed-phase HPLC with UV detection. The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with octadecyl silica was first conditioned with methanol and pH 7.4 phosphate buffer. A 0.8-ml volume of diluted plasma sample containing the internal standard (sulindac) was then applied on the DEC. The washing step was performed with the same buffer (pH 7.4). Finally, the analytes were successively eluted with methanol (1.0 ml) and 0.04 M phosphoric acid (1.0 ml). After a mixing step, 100 μl of the resultant extract was directly introduced into the HPLC system. The liquid chromatographic (LC) separation of the analytes was achieved on a Nucleosil RP-8 stationary phase (5 μm). The mobile phase consisted of a mixture of methanol and 0.04 M phosphoric acid (60:40, v/v). The analyte was monitored photometrically at 288 nm. The method developed was validated. In these conditions, the absolute recovery of fenofibric acid was close to 100% and a linear calibration curve was obtained in the concentration range from 0.25 to 20 μg/ml. The mean RSD values for repeatability and intermediate precision were 1.7 and 3.9% for fenofibric acid. The method developed was successfully used to investigate the bioequivalence between a micronized fenofibrate capsule formulation and a fenofibrate Lidose™ formulation.  相似文献   

7.
A high-performance liquid chromatographic method for the determination of the histamine H1-receptor antagonist cetirizine in human urine was developed. Cetirizine and the internal standard are extracted from acidified (pH 5) urine (0.5 ml) into chloroform and the organic layer is evaporated to dryness. The residue is chromatographed on a Spherisorb 5ODS-2 column using Pic A (5 mM aqueous tetrabutylammonium phosphate)—methanol—tetrahydrofuran (33:65:2, v/v) as the mobile phase with ultraviolet detection (230 nm). The calibration graph is linear from 0.1 to 10 μg/ml and using 0.5 ml of urine the detection limit is 20 ng/ml. The within-run relative standard deviation is <6% and the accuracy is within 10% of the theoretical value at concentrations between 0.1 and 10 μg/ml in urine. There is a good correlation (r = 0.99606) with a previously described capillary gas chromatographic assay.  相似文献   

8.
As a part of a pilot clinical study, a high-performance reversed-phase liquid chromatography analysis was developed to quantify temozolomide in plasma and urine of patients undergoing a chemotherapy cycle with temozolomide. All samples were immediately stabilized with 1 M HCl (1 + 10 of biological sample), frozen and stored at −20°C prior to analysis. The clean-up procedure involved a solid-phase extraction (SPE) of clinical sample (100 μl) on a 100-mg C18-endcapped cartridge. Matrix components were eliminated with 750 μl of 0.5% acetic acid (AcOH). Temozolomide was subsequently eluted with 1250 μl of methanol (MeOH). The resulting eluate was evaporated under nitrogen at RT and reconstituted in 200 μl of 0.5% AcOH and subjected to HPLC analysis on an ODS-column (MeOH-0.5% AcOH, 10:90) with UV detection at 330 nm. The calibration curves were linear over the concentration range 0.4–20 μg/ml and 2–150 μg/ml for plasma and urine, respectively. THe extraction recovery of temozolomide was 86–90% from plasma and 103–105% from urine over the range of concentrations considered. The stability of temozolomide was studied in vitro in buffered solutions at RT, and in plasma and urine at 37°C. An acidic pH (<5–6) shoul be maintained throughout the collection, the processing and the analysis of the sample to preserve the integrity of the drug. The method reported here was validated for use in a clinical study of temozolomide for the treatment of metastatic melanoma and high grade glioma.  相似文献   

9.
High-temperature headspace solid-phase microextraction (SPME) with simultaneous (“in situ”) derivatisation (acetylation or silylation) is a new sample preparation technique for the screening of illicit drugs in urine and for the confirmation analysis in serum by GC–MS. After extraction of urine with a small portion of an organic solvent mixture (e.g., 2 ml of hexane–ethyl acetate) at pH 9, the organic layer is separated and evaporated to dryness in a small headspace vial. A SPME-fiber (e.g., polyacrylate) doped with acetic anhydride–pyridine (for acetylation) is exposed to the vapour phase for 10 min at 200°C in a blockheater. The SPME fiber is then injected into the GC–MS for thermal desorption and analysis. After addition of perchloric acid and extraction with n-hexane to remove lipids, the serum can be analysed after adjusting to pH 9 as described for urine. Very clean extracts are obtained. The various drugs investigated could be detected and identified in urine by the total ion current technique at the following concentrations: amphetamines (200 μg/l), barbiturates (500 μg/l), benzodiazepines (100 μg/l), benzoylecgonine (150 μg/l), methadone (100 μg/l) and opiates (200 μg/l). In serum all drugs could be detected by the selected ion monitoring technique within their therapeutic range. As compared to liquid–liquid extraction only small amounts of organic solvent are needed and larger amounts of the pertinent analytes could be transferred to the GC column. In contrast to solid-phase extraction (SPE), the SPME-fiber is reusable several times (as there is no contamination by endogenous compounds). The method is time-saving and can be mechanised by the use of a dedicated autosampler.  相似文献   

10.
A simple high-performance liquid chromatographic method was developed for the determination of vanillin and its vanillic acid metabolite in human plasma, red blood cells and urine. The mobile phase consisted of aqueous acetic acid (1%, v/v)–acetonitrile (85:15, v/v), pH 2.9 and was used with an octadecylsilane analytical column and ultraviolet absorbance detection. The plasma method demonstrated linearity from 2 to 100 μg/ml and the urine method was linear from 2 to 40 μg/ml. The method had a detection limit of 1 μg/ml for vanillin and vanillic acid using 5 μl of prepared plasma, red blood cells or urine. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of vanillin in patients undergoing treatment for sickle cell anemia.  相似文献   

11.
A reversed-phase high-performance liquid chromatographic method for oxazepam in human urine samples has been developed. The sample preparation consists of an enzymatic hydrolysis with β-glucuronidase, followed by a solid-phase extraction process using Bond-Elut C2 cartridges. The mobile phase used was a methanol—water (60:40, v/v) mixture at a flow-rate of 0.50 ml/min. The column was a 3.5 cm × 4.6 mm I.D. C18 reversed-phase column. The detection system was based on a fluorescence post-column derivatization of oxazepam in mixtures of methanol and acetic acid. A linear range from 0.01 to 1 μg/ml of urine and a limit of detection of 4 ng/ml of urine were attained. Within-day recoveries and reproducibilities from urine samples spiked with 0.2 and 0.02 μg/ml oxazepam were 97.9 and 95.0 and 2.1 and 9.4%, respectively.  相似文献   

12.
We have developed and validated a sensitive and selective assay for the quantification of paclitaxel and its metabolites 6α,3′-p-dihydroxypaclitaxel, 3′-p-hydroxypaclitaxel and 6α-hydroxypaclitaxel in plasma, tissue, urine and faeces specimens of mice. Tissue and faeces were homogenized (approximately 0.1–0.2 g/ml) in bovine serum albumin (40 g/I) in water, and urine was diluted (1:5, v/v) in blank human plasma. Sample pretreatment involved liquid-liquid extraction of 200–1000 μl of sample with diethyl ether followed by automated solid-phase extraction using cyano Bond Elut column. 2′-Methylpaclitaxel was used as internal standard. The overall recovery of the sample pretreatment procedure ranged from 76 ot 85%. In plasma, the lower limit of detection (LOD) and the lower limit of quantitation (LLQ) are 15 and 25 ng/ml, respectively, using 200 μl of sample. In tissues, faeces and urine the LLQs are 25–100 ng/g, 125 ng/g and 25 ng/ml, respectively, using 1000 μl (faeces: 200 μl) of homogenized or diluted sample. The concentrations in the various biological matrices, for validation procedures spiked with known amounts of the test compounds, are read from calibration curves constructed in blank human plasma in the range 25–100 000 ng/ml for paclitaxel and 25–500 ng/ml for the metabolites. The accuracy and precision of the assay fall within the generally accepted criteria for bio-analytical assays.  相似文献   

13.
A method for the determination of hexahydrophthalic acid, a metabolite of hexahydrophthalic anhydride, in human urine has been developed. The urine was worked-up by liquid—solid extraction, esterified with boron trifluoride—methanol, and analysed by capillary gas chromatography and selected-ion monitoring. Hexadeuterium-labelled hexahydrophthalic acid was used as the internal standard. The precision was 4% at 0.7 μg/ml and 5% at 0.07 μg/ml. The recovery of the acid for the overall method was 101% at 0.07 μg/ml of urine (with a coefficient of variation of 4%) and 95% at 0.7 μg/ml (coefficient of variation 2%). The limit of detection was 20 ng/ml urine.  相似文献   

14.
Automated procedures for the determination of CGP 33 101 in plasma and the simultaneous determination of CGP 33 101 and its carboxylic acid metabolite, CGP 47 292, in urine are described. Plasma was diluted with water and urine with a pH 2 buffer prior to extraction. The compounds were automatically extracted on reversed-phase extraction columns and injected onto an HPLC system by the automatic sample preparation with extraction columns (ASPEC) automate. A Supelcosil LC-18 (5 μm) column was used for chromatography. The mobile phase was a mixture of an aqueous solution of potassium dihydrogen phosphate, acetonitrile and methanol for the assay in plasma, and of an aqueous solution of tetrabutylammonium hydrogen sulfate, tripotassium phosphate and phosphoric acid and of acetonitrile for the assay in urine. The compounds were detected at 230 nm. The limit of quantitation was 0.11 μml/l (25 ng/mol) for the assay of CGP 33 101 in plasma, 11 μmol/l (2.5 μg/ml) for its assay in urine and 21 μmol/l (5 μg/ml) for the assay of CGP 47 292 in urine.  相似文献   

15.
A high-performance liquid chromatographic method for the determination of picotamide in human plasma and urine is described. After addition of an internal standard (bamifylline), the plasma and urine samples were subjected to liquid—liquid extraction and clean-up procedures. The final extracts were evaporated to dryness and the resulting residues were reconstituted in 100 μl of methanol—water (50:50, v/v) and chromatographed on a LiChrosorb RP-SELECT B reversed-phase column coupled to an ultraviolet detector monitored at 230 nm. Chromatographic analysis takes about 10 min per sample. The assay was linear over a wide range and has a limit of detection of 0.005 and 0.1 μg/ml in plasma and urine, respectively. It was selective for picotamide, accurate and robust and thus suitable for routine assays after therapeutic doses of picotamide.  相似文献   

16.
A novel solid-phase extraction (SPE) method and HPLC method were developed for the determination of methadone and its metabolite from spiked human urine. For sample cleanup, a spiked urine sample was pretreated with phosphoric acid followed by a well-thought-out SPE method using a 10-mg Oasis HLB 96-well extraction plate. In this SPE method, the concentration of methanol as well as the pH are optimized to preferentially isolate the analytes of interest from the sample matrix. Low elution volumes (200 μl) are achieved; this eliminates evaporation and reconstitution of the sample solution. Recoveries from human urine matrix were greater than 91% with RSD values less than 4.5%. For the HPLC analysis, the separation was obtained using a SymmetryShield RP18 column with a mobile phase of 0.1% TFA–methanol (60:40, v/v). Good peak shapes were obtained without the need of addition of any competing reagent to the mobile phase. Additionally, significant signal-to-noise enrichment was achieved by diluting the final SPE eluates four-fold with water.  相似文献   

17.
A rapid HPLC method with solid-phase extraction (SPE) clean-up for malachite green (MG) and leucomalachite green (LMG) in eel plasma was developed. MG and LMG were extracted with a buffered methanolic solution. The extract was subjected to aromatic sulphonic acid SPE. MG and LMG were eluted from the SPE column with methanol after a treatment with ammonia gas. The reconstituted eluate was analyzed on a Chromspher B column with acetonitrile-ion-pair buffer (ph 4.0) (6:4, v/v) as the mobile phase and detection at 610 nm after post column oxidation with PbO2. The average recoveries for MG and LMG over the linear range of applicability (20–2500 ng/ml) were 82±1% and 83±1%, respectively. The limits of quantification were 5.0 μg/1 for MG and 0.9 μ/1 for LMG.  相似文献   

18.
A chromatographic method was developed for the T-514 determination in Karwinskia leaves, stems and roots. A C18 analytical column and a mobile phase consisting of methanol and McIlvaine buffer (pH 3) were used. T-514 was detected using a diode array detector and the chromatograms were recorded at 269 and 410 nm. A linear dependence of a peak area on the T-514 concentration (r=0.9991) was obtained in the range of 0.126–12.6 μg/ml. Limits of T-514 quantification (signal-to-noise ratio 10) in plant samples were 126 ng/ml at 410 nm and 28 ng/ml at 269 nm. T-514 was extracted from the plant material with ethyl acetate. Optimal extraction conditions were studied: number of extraction steps, volume of extracting agent and extraction time. The extracts were cleaned up using solid-phase extraction (SPE). SPE recoveries of 99.9% and 98.4% were achieved for the T-514 concentrations of 1.4 μg/ml and 0.26 μg/ml, respectively.  相似文献   

19.
A simple, rapid and reproducible reversed-phase high-performance liquid chromatographic method for the simultaneous determination of benzoic acid (BA), phenylacetic acid (PAA) and their respective glycine conjugates hippuric acid (HA) and phenaceturic acid (PA) in sheep urine is described. The procedure involves only direct injection of a diluted urine sample, thus obviating the need for an extraction step or an internal standard. The compounds were separated on a Nova-Pak C18 column with isocratic elution with acetate buffer (25 mM, pH 4.5)—methanol (95:5). A flow-rate of 1.0 ml/min, a column temperature of 35°C and detection at 230 nm were employed. These conditions were optimized by investigating the effects of pH, molarity, methanol concentration in the mobile phase and column temperature on the resolution of the metabolites. The total analysis time was less than 15 min per sample. At a signal-to-noise ratio of 3 the detection limits for ten-fold diluted urine were 1.0 μg/ml for BA and HA and 5.0 μg/ml for PAA and PA with a 20-μl injection.  相似文献   

20.
An automated reversed-phase high-performance liquid chromatographic (RP-HPLC) method, using a linear gradient elution, is described for the simultaneous analysis of caffeine and metabolites according to their elution order: 7-methyluric acid, 1-methyluric acid, 7-methylxanthine, 3-methylxanthine, 1-methylxanthine, 1,3-dimethyluric acid, theobromine, 1,7-dimethyluric acid, paraxanthine and theophylline. The analytical column, an MZ Kromasil C4, 250×4 mm, 5 μm, was operated at ambient temperature with back pressure values of 80–110 kg/cm2. The mobile phase consisted of an acetate buffer (pH 3.5)–methanol (97:3, v/v) changing to 80:20 v/v in 20 min time, delivered at a flow-rate of 1 ml/min. Paracetamol was used as internal standard at a concentration of 6.18 ng/μl. Detection was performed with a variable wavelength UV–visible detector at 275 nm, resulting in detection limits of 0.3 ng per 10-μl injection, while linearity held up to 8 ng/μl for most of analytes, except for paraxanthine and theophylline, for which it was 12 ng/μl and for caffeine for which it was 20 ng/μl. The statistical evaluation of the method was examined performing intra-day (n=6) and inter-day calibration (n=7) and was found to be satisfactory, with high accuracy and precision results. High extraction recoveries from biological matrices: blood serum and urine ranging from 84.6 to 103.0%, were achieved using Nexus SPE cartridges with hydrophilic and lipophilic properties and methanol–acetate buffer (pH 3.5) (50:50, v/v) as eluent, requiring small volumes, 40 μl of blood serum and 100 μl of urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号