 共查询到20条相似文献,搜索用时 156 毫秒
1.
A novel flexible sensor was developed for the noninvasive oxygen metabolism measurement of cultivated cells and tissues. This device is composed of a transparent double-layered polymer sheet of ethylene-vinyl alcohol (EVOH) and poly(dimethylsiloxane) (PDMS) having an array of microhole structures of 90 μm diameter and 50 μm depth on its surface. All the microhole structures were equipped with a 1-μm-thick optical chemical sensing layer of platinum porphyrin-fluoropolymer on their bottom. The three-dimensional microstructures of the sensor were fabricated by a newly developed simple and low-cost production method named self-aligned hot embossing. The device was designed to be attached slightly above the cells cultivated on a dish to form a temporarily closed microspace over the target cells during measurement. Since the change in oxygen concentration is relatively fast in the microcompartmentalized culture medium, a rapid evaluation of the oxygen consumption rate is possible by measuring the phosphorescence lifetime of the platinum porphyrin-fluoropolymer. The combined use of the device and an automated optical measurement system enabled the high-throughput sensing of cellular oxygen consumption (100 points/min). We monitored the oxygen metabolism of the human breast cancer cell line MCF7 on a Petri dish and evaluated the oxygen consumption rate to be 0.72 ± 0.12 fmol/min/cell. Furthermore, to demonstrate the utility of the developed sensing system, we demonstrated the mapping of the oxygen consumption rate of rat brain slices and succeeded in visualizing a clear difference among the layer structures of the hippocampus, i.e., the cornu ammonis (CA1 and CA3) and dentate gyrus (DG).  相似文献   

2.
The oxygen distribution in various bio-hybrid systems composed of cellular tissue on an artificial scaffold was estimated by mathematically modeling the oxygen consumption and diffusion. Mathematical models were established for practical systems such as bio-hybrid artificial liver (BAL) and bio-hybrid blood vessels, and the calculated results were compared with corresponding experimental data. Analysis of a spherical organoid (“spheroid”) composed of hepatic cells suggested that the oxygen consumption rate in hepatocyte spheroids incubated in a BAL is one or two orders of magnitude larger than the total average value that had been calculated for various organs. A model was established for a BAL system on a scaffold of commercially available hollow fiber (typical inner and outer radii of 150 and 200 μm) to determine the optimal conditions under which the hepatocytes can be packed as closely as possible into the hollow fiber lumen while still maintaining viability without falling into oxygen deficiency. A model of bio-hybrid blood vessels formed by vascular endothelial cells incubated on the inner wall of a hollow fiber scaffold was used to estimate the maximum thickness of viable endothelial tissue under various conditions of outer partial oxygen pressure and different sizes and permeabilities of the hollow fiber scaffold. The model suggested that the oxygen supply becomes quite restricted when the hollow fiber membrane is thicker than 100 μm; the thickness of the endothelium in a 500 μm-thick hollow fiber membrane was estimated to be 7 μm at most, even when the membrane permeability was as large as that of the culture medium.  相似文献   

3.
This protocol describes an electron spin resonance (ESR) micro-imaging method for three-dimensional mapping of oxygen levels in the immediate environment of live cells with micron-scale resolution1. Oxygen is one of the most important molecules in the cycle of life. It serves as the terminal electron acceptor of oxidative phosphorylation in the mitochondria and is used in the production of reactive oxygen species. Measurements of oxygen are important for the study of mitochondrial and metabolic functions, signaling pathways, effects of various stimuli, membrane permeability, and disease differentiation. Oxygen consumption is therefore an informative marker of cellular metabolism, which is broadly applicable to various biological systems from mitochondria to cells to whole organisms. Due to its importance, many methods have been developed for the measurements of oxygen in live systems. Current attempts to provide high-resolution oxygen imaging are based mainly on optical fluorescence and phosphorescence methods that fail to provide satisfactory results as they employ probes with high photo-toxicity and low oxygen sensitivity. ESR, which measures the signal from exogenous paramagnetic probes in the sample, is known to provide very accurate measurements of oxygen concentration. In a typical case, ESR measurements map the probe''s lineshape broadening and/or relaxation-time shortening that are linked directly to the local oxygen concentration. (Oxygen is paramagnetic; therefore, when colliding with the exogenous paramagnetic probe, it shortness its relaxation times.) Traditionally, these types of experiments are carried out with low resolution, millimeter-scale ESR for small animals imaging. Here we show how ESR imaging can also be carried out in the micron-scale for the examination of small live samples. ESR micro-imaging is a relatively new methodology that enables the acquisition of spatially-resolved ESR signals with a resolution approaching 1 micron at room temperature2. The main aim of this protocol-paper is to show how this new method, along with newly developed oxygen-sensitive probes, can be applied to the mapping of oxygen levels in small live samples. A spatial resolution of ~30 x 30 x 100 μm is demonstrated, with near-micromolar oxygen concentration sensitivity and sub-femtomole absolute oxygen sensitivity per voxel. The use of ESR micro-imaging for oxygen mapping near cells complements the currently available techniques based on micro-electrodes or fluorescence/phosphorescence. Furthermore, with the proper paramagnetic probe, it will also be readily applicable for intracellular oxygen micro-imaging, a capability which other methods find very difficult to achieve.  相似文献   

4.
目的: 在初步验证超快反应聚合物基质光纤氧传感器及其测定系统记录颈动脉氧分压(PaO2)连续动态变化使用基础上,为了分析探讨肺通气对PaO2连续动态变化的影响,我们设计本活体整体动物实验观察研究。方法: 选择杂种山羊4只,全身麻醉气管插管空气机械通气下,切皮直接暴露把后接测定系统的氧传感器直接插入左侧颈动脉连续记录PaO2动态变化。正常分钟通气量机械通气分别通过三种潮气量实施:正常潮气量(潮气量VT=15 ml/kg、呼吸频率Rf=20 bpm)、减半潮气量(VT减半、Rf加倍)和加倍潮气量(VT加倍、Rf减半)。三种潮气量通气时间分别稳定10~15 min,选取后180 s分析计算PaO2平均值、呼吸间PaO2变化的升降幅度和肺-颈动脉延迟时间。以ANOVA及两两比较统计学差异分析不同潮气量的影响。结果: 活体山羊正常通气量机械通气实验时心率和血压均稳定;肺-颈动脉延迟时间为1.4~1.8 s(约为此时的3次心跳)。机械通气正常潮气量下PaO2平均值在(102.94±2.40,99.38~106.16)mmHg,升降幅度是(21.43±1.65,19.21~23.59)mmHg,占平均值的(20.80±1.34,18.65~22.22)%;减半潮气量下,PaO2平均值维持在(101.01±4.25,94.09~105.66)mmHg,虽略降但不显著(与正常机械通气比较P>0.05),但PaO2升降变化幅度却显著降低为(18.14±1.43,16.46~20.05) mmHg,占平均值的(17.95±1.07,16.16~18.98)%(与正常机械通气比较P<0.01);加倍潮气量机械通气下,虽仅略升的PaO2平均值维持在(106.42±4.74,101.19~114.08)mmHg(与正常机械通气比较P>0.05,与减半潮气量机械通气比较P<0.05),但PaO2升降幅度却显著增大为(26.58±1.88,23.46~28.46)mmHg,占平均值的24.99%±1.58%(与正常机械通气和减半潮气量比较P均<0.01)。结论: 正常肺通气的吸气和呼气是颈动脉PaO2上升和下降的始动因素。正常通气量机械通气下减半潮气量和倍增潮气量显著改变PaO2升降幅度,但PaO2平均值仅小幅改变,而肺-颈动脉延迟时间相近。  相似文献   

5.
Because the regulation of microcirculation in the cerebral cortex cannot be analyzed without measuring the blood flow dynamics and oxygen concentration in cerebral microvessels, we developed a fluorescence and phosphorescence system for estimating red blood cell velocity and oxygen tension in cerebral microcirculation noninvasively and continuously with high spatial resolution. Using red blood cells labeled with fluorescent isothiocyanate to visualize red cell distribution and using the oxygen quenching of Pd-meso-tetra-(4-carboxyphenyl)-porphyrin phosphorescence to measure oxygen tension enabled simultaneous measurement of blood velocity and oxygen tension. We examined how the measurement accuracy was affected by the spatial resolution and by the excitation laser light passing through the targeted microvessel and exciting the oxygen probe dye in the tissue beneath it. Focusing the excitation light into the microvessel stabilized the phosphorescence lifetime at each spatial resolution; moreover, it greatly reduced phosphorescence from the brain tissue. Animal experiments involving acute hemorrhagic shock demonstrated the feasibility of our system by showing that the changes in venular velocity and oxygen tension are synchronized to the change in mean arterial pressure. Our system measures the red cell velocity and oxygen concentration in the cerebral microcirculation by using the differences in luminescence and wavelength between fluorescence and phosphorescence, making it possible to easily acquire information about cerebral microcirculatory distribution and oxygen tension simultaneously.  相似文献   

6.
Metabolic responses of mammalian cells toward declining oxygen concentration are generally thought to occur when oxygen limits mitochondrial ATP production. However, at oxygen concentrations markedly above those limiting to mitochondria, several mammalian cell types display reduced rates of oxygen consumption without energy stress or compensatory increases in glycolytic ATP production. We used mammalian Jurkat T cells as a model system to identify mechanisms responsible for these changes in metabolic rate. Oxygen consumption was 31% greater at high oxygen (150–200 μM) compared to low oxygen (5–10 μM). Hydrogen peroxide was implicated in the response as catalase prevented the increase in oxygen consumption normally associated with high oxygen. Cell-derived hydrogen peroxide, predominately from the mitochondria, was elevated with high oxygen. Oxygen consumption related to intracellular calcium turnover was shown, through EDTA chelation and dantrolene antagonism of the ryanodine receptor, to account for 70% of the response. Oligomycin inhibition of oxygen consumption indicated that mitochondrial proton leak was also sensitive to changes in oxygen concentration. Our results point toward a mechanism in which changes in oxygen concentration influence the rate of hydrogen peroxide production by mitochondria, which, in turn, alters cellular ATP use associated with intracellular calcium turnover and energy wastage through mitochondrial proton leak.  相似文献   

7.
This study describes the use of two-photon excitation phosphorescence lifetime measurements for quantitative oxygen determination in vivo. Doubling the excitation wavelength of Pd-porphyrin from visible light to the infrared allows for deeper tissue penetration and a more precise and confined selection of the excitation volume due to the nonlinear two-photon effect. By using a focused laser beam from a 1,064-nm Q-switched laser, providing 10-ns pulses of 10 mJ, albumin-bound Pd-porphyrin was effectively excited and oxygen-dependent decay of phosphorescence was observed. In vitro calibration of phosphorescence lifetime vs. oxygen tension was performed. The obtained calibration constants were kq = 356 Torr(-1) x s(-1) (quenching constant) and tau0 = 550 micros (lifetime at zero-oxygen conditions) at 37 degrees C. The phosphorescence intensity showed a squared dependency to the excitation intensity, typical for two-photon excitation. In vivo demonstration of two-photon excitation phosphorescence lifetime measurements is shown by step-wise PO2 measurements through the cortex of rat kidney. It is concluded that quantitative oxygen measurements can be made, both in vitro and in vivo, using two-photon excitation oxygen-dependent quenching of phosphorescence. The use of two-photon excitation has the potential to lead to new applications of the phosphorescence lifetime technique, e.g., noninvasive oxygen scanning in tissue at high spatial resolution. To our knowledge, this is the first report in which two-photon excitation is used in the setting of oxygen-dependent quenching of phosphorescence lifetime measurements.  相似文献   

8.
Geometry of tapered fiber sensors critically affects the response of an evanescent field sensor to cell suspensions. Single-mode fibers (nominally at 1300 nm) were tapered to symmetric or asymmetric tapers with diameters in the range of 3–20 μm, and overall lengths of 1–7 mm. Their transmission characteristics in air, water and in the presence of Escherichia coli (JM101 strain) at concentrations of 100, 1000, 7000 and 7 million cells/mL were measured in the 400–800 nm range and gave rich spectral data that lead to the following conclusions. (1) No change in transmission was observed due to E. coli with tapers that showed no relative change in transmission in water compared to air. (2) Tapers that exhibited a significant difference in transmission in water compared to air gave weak response to the presence of the E. coli. Of these, tapers with low waist diameters (6 μm) showed sensitivity to E. coli at 7000 cells/mL and higher concentration. (3) Tapers that showed modest difference in water transmission compared to air, and those that had small waist diameters gave excellent response to E. coli at 100–7000 cells/mL. In addition, mathematical modeling showed that: (1) at low wavelength (470 nm) and small waist diameter (6 μm), transmission with water in the waist region is higher than in air. (2) Small changes in waist diameter (0.05 μm) can cause larger changes in transmission at 470 nm than at 550 nm at waist diameter of 6 μm. (3) For the same overall geometry, a 5.5 μm diameter taper showed larger refractive index sensitivity compared to a 6.25 μm taper at 470 nm.  相似文献   

9.
We investigated the fluorescence lifetime of pyrene butyric acid (PBA) using various O2 concentrations in cells. Both in living and freshly fixed cells, PBA lifetime decreased with oxygen concentration. We recorded decay curves in single cells and measured PBA lifetime and NAD(P)H intensity values. Under nitrogen atmosphere, the probe lifetime differences (199 and 209 ns in living and freshly fixed cells, respectively) suggest a supplemental pathway for the deactivation of the probe when the cell functions are not stopped. We propose reactive oxygen species (ROS) to be the additional quenchers that cause this decrease. We further studied the effect of drugs generating ROS the anthracycline doxorubicin (adriamycin). For living cells, PBA lifetime decreased after adriamycin (ADR) treatment (200 and 1000 ng/ml). This supports our hypothesis that under nitrogen atmosphere and for freshly fixed cells, PBA lifetimes increase to an unchanging value due to absence of quenchers.  相似文献   

10.
New optical nanoresonance effects enabled us to study the effect of ions on nanometric carbohydrate thin layers on chips. Immobilization was done via spin coating of the derivatized carbohydrate polymer at a metallized chip surface forming ultrathin films (about 50-300 nm thick) followed by photochemical cross-linking. Deposition of metal-nanoclusters, synthesized by chemical means and sputter coating on top of the polymer, induced an optical resonance effect, which transduced changes of polymer structure quantitatively into an optical signal that can be observed directly as resonance shift of a narrow optical peak. The response of the sensor chip even visible to the eye was quantified spectroscopically in the visible and ir range of the spectrum. The lifetime of thin film was good, and thus application as a sensor was limited only by the mechanical stability of the reactive matrix, but not by photobleaching or molecular leakage. Due to the inherent hydrophilic nature of the alginate polymer, the response time of this new sensor is governed by simple aqueous diffusion of the ionic calcium for up to 300 nm completed within less than one second. Monitoring of calcium fluctuations in a high background of magnesium and even serum was demonstrated with a dynamic range optimal for physiological measurements and a linear response up to 5 mM. Surface and alignment of polymer chain were influenced by the nanostructure of the supporting metal film-contrary to alginic acid, chitosan was deposited well aligned to the nanocrystals of the support.  相似文献   

11.
Uncovering principles that regulate energy metabolism in the brain requires mapping of partial pressure of oxygen (PO(2)) and blood flow with high spatial and temporal resolution. Using two-photon phosphorescence lifetime microscopy (2PLM) and the oxygen probe PtP-C343, we show that PO(2) can be accurately measured in the brain at depths up to 300 μm with micron-scale resolution. In addition, 2PLM allowed simultaneous measurements of blood flow and of PO(2) in capillaries with less than one-second temporal resolution. Using this approach, we detected erythrocyte-associated transients (EATs) in oxygen in the rat olfactory bulb and showed the existence of diffusion-based arterio-venous shunts. Sensory stimulation evoked functional hyperemia, accompanied by an increase in PO(2) in capillaries and by a biphasic PO(2) response in the neuropil, consisting of an 'initial dip' and a rebound. 2PLM of PO(2) opens new avenues for studies of brain metabolism and blood flow regulation.  相似文献   

12.
We report here on a low-cost, optical oxygen sensor as an attractive alternative to the widely used amperometric Clark-type oxygen electrode for measuring dissolved oxygen tensions in cell cultures and bioreactor. Our sensor is based on the defferential quenching of the fluorescence lifetime of chromophore in response to the partial pressure of oxygen. This is measured as a phase shift in fluorescence emission from the chromophore due to oxygen quenching when excited by an intensity modulated beam of light. In this article we demonstrate the advantages of lifetime-based optical methods over both intensity based optical methods and amperometric electrodes. Our sensor is particularly suitable for measuring dissolved oxygen in bioreactors. It is autoclavable, is free of maintenance requirements, and solvents the problems of long-term stability, calibration drifts, and reliable measurement of low oxygen tensions in dense microbial cultures that limit the utility of Clark-type elcectordes. (c) 1994 John Wiley & Sons, Inc.  相似文献   

13.
We have developed an optical method for the evaluation of the oxygen consumption (Vo(2)) in microscopic volumes of spinotrapezius muscle. Using phosphorescence quenching microscopy (PQM) for the measurement of interstitial Po(2), together with rapid pneumatic compression of the organ, we recorded the oxygen disappearance curve (ODC) in the muscle of the anesthetized rats. A 0.6-mm diameter area in the tissue, preloaded with the phosphorescent oxygen probe, was excited once a second by a 532-nm Q-switched laser with pulse duration of 15 ns. Each of the evoked phosphorescence decays was analyzed to obtain a sequence of Po(2) values that constituted the ODC. Following flow arrest and tissue compression, the interstitial Po(2) decreased rapidly and the initial slope of the ODC was used to calculate the Vo(2). Special analysis of instrumental factors affecting the ODC was performed, and the resulting model was used for evaluation of Vo(2). The calculation was based on the observation of only a small amount of residual blood in the tissue after compression. The contribution of oxygen photoconsumption by PQM and oxygen inflow from external sources was evaluated in specially designed tests. The average oxygen consumption of the rat spinotrapezius muscle was Vo(2) = 123.4 ± 13.4 (SE) nl O(2)/cm(3) · s (N = 38, within 6 muscles) at a baseline interstitial Po(2) of 50.8 ± 2.9 mmHg. This technique has opened the opportunity for monitoring respiration rates in microscopic volumes of functioning skeletal muscle.  相似文献   

14.
Intra-aortic measurement of nitric oxide (NO) would provide valuable insights into NO bioavailability in systemic circulation and vascular endothelial function. In the present study, we thus developed a catheter-type NO sensor to measure intra-aortic NO concentration in vivo. An NO sensor was encased and fixed in a 4-Fr catheter. The sensor was then located in the thoracic aorta via the femoral artery through a 7-Fr catheter to measure intra-aortic plasma NO concentration in vivo in anesthetized dogs. Infusion of acetylcholine (10 microg/kg) increased base-to-peak plasma NO level in the aorta by 2.4+/-0.4 nM (n=7). After 20-min infusion of N(G)-methyl-L-arginine (NO synthase inhibitor), changes in plasma NO concentration in response to acetylcholine were attenuated significantly (1.8+/-0.4 nM, P<0.003, n=7). In conclusion, the newly developed catheter-type NO sensor successfully measured acetylcholine-induced changes in intra-aortic plasma concentration of endothelium-derived NO in vivo and demonstrated applicability to direct evaluation of intravascular NO bioavailability.  相似文献   

15.
Platinum(II) and palladium(II) complexes of porphyrins and related tetrapyrrolic pigments emit strong phosphorescence at room temperatures, which is characterized by long lifetimes falling into the sub-millisecond range and long-wave spectral characteristics. These features make the dyes useful as probes for a number of bioanalytical applications, particularly those employing time-resolved fluorescent detection. They can provide high sensitivity and selectivity, together with rather simple instrumental set-up. A number of analytical systems are now under development that are based on the use of phosphorescent porphyrin probes. Experimental results are presented on the following systems: (i) fibre-optic phosphorescence lifetime-based oxygen sensor on the basis of hydrophobic platinum-porphyrins and development of advanced sensing materials and prototype instrumentation; (ii) practical applications of the optical oxygen sensor, including a sensitive immunosensor that employs glucose oxidase labels, a rapid screening method for cell viability in microtitre-plate format, non-destructive measurement of oxygen in packaged foods and reagentless biosensors for metabolites (glucose, lactate); and (iii) the use of water-soluble platinum- and palladium-porphyrins as labels for ultra-sensitive time-resolved phosphorescence immunoassays.  相似文献   

16.
An optical polymeric biochip system based on the complementary metal oxide semiconductor (CMOS) photo array sensor and polymeric enzyme biochip for rapidly quantitating uric acid in a one-step procedure was developed. The CMOS sensor was designed with N+/P-well structure and manufactured using a standard 0.5 μm CMOS process. The polymeric enzyme biochip was immobilized with uricase–peroxidase and used to fill the reacting medium with the sample. This study encompasses the cloning of the Bacillus subtilis uricase gene and expression in Escherichia coli, as well as the purification of uricase and measurement of its activity. The cloned uricase gene included an open reading frame of 1491 nucleotides that encodes a protein of approximately 55 kDa. The expression of the putative MBP-fusion protein involved approximately 98 kDa of the protein. The CMOS sensor response was stronger at a higher temperature range of 20–40 °C, with optimal pH at 8.5. The calibration curve of purified uric acid was linear in the concentration range from 2.5 to 12.5 mg/dL. The results obtained for serum uric acid correlated quite closely with those obtained using the Beckman Synchron method.  相似文献   

17.
目的: 我们在中国尝试使用超快反应聚合物光纤氧感受器置入整体活体动物动脉血管,再通过光电转换测定系统以记录活体动物颈动脉PO2(PaO2)连续动态的快速变化,为完善整体整合生理学理论体系中循环参与呼吸调控和呼吸循环代谢一体化调控提供实验依据。方法: ①超快反应氧感受器制作、性能及其测定系统标定:在实验室加热总长2 m光纤的远端5 mm部分,拉动直到它成锥形尖端,清洁并干燥后,将1 mm锥形光纤尖端浸涂到发光体掺杂聚合物溶液中,在溶剂快速蒸发同时将其缓慢抽出来形成氧气感测尖端,室温干燥24 h。对完成制作的感受器进行性能标定,并于第37日重复标定。②动物实验:在潍坊医学院实验室对山羊全麻气管插管氧气机械通气下,切皮暴露双颈动脉和左侧股动脉,分别把超快反应氧传感器直接插入动脉中,通过光导纤维、激发与检测Y型光纤耦合器经光电转换连接到个人电脑,实现机械通气下活体山羊颈动脉PaO2的连续动态反应,主要分析PaO2的呼吸间波浪式交替升降和肺-颈动脉时间延迟。结果: 该置入式超快反应氧传感器在液相的响应时间为100 ms。活体山羊实验40%~60%氧气机械通气心率和血压稳定,左和右颈动脉PaO2随着呼吸机的吸气和呼气呈现波浪式上升和下降的呼吸交替现象,幅度高达15 mmHg;左侧股动脉位置记录的信息噪音显著干扰PaO2变化。肺-颈动脉时间延迟是在吸气和呼气开始后1.5~1.7 s左侧和右侧颈动脉PaO2都开始上升和下降;即肺通气开始后3次心跳,左心室可把肺毛细血管后动脉化的肺静脉血液送到外周化学感受器位置中断吸气切换为呼气和中断呼气切换为吸气,如此实现吸呼周而复始。结论: 活体动物置入动脉的超快反应氧传感器及其测定系统可测定PaO2生理性波浪式变化,能为整体整合生理学医学新理论体系中解释吸气和呼气相互切换的机制提供实验依据。  相似文献   

18.
The phosphorescence emission of Cd-azurin from Pseudomonas aeruginosa was used as a probe of possible perturbations in the dynamical structure of the protein core that may be induced by protein-sorbent and protein-protein interactions occurring when the macromolecule is deposited into amorphous, thin solid films. Relative to the protein in aqueous solution, the spectrum is unrelaxed and the phosphorescence decay becomes highly heterogeneous, the average lifetime increasing sharply with film thickness and upon its dehydration. According to the lifetime parameter, adsorption of the protein to the substrate is found to produce a multiplicity of partially unfolded structures, an influence that propagates for several protein layers from the surface. Among the substrates used for film deposition, hydrophilic silica, dextran, DEAE-dextran, dextran sulfate, and hydrophobic octodecylamine, the perturbation is smallest with dextran sulfate and largest with octodecylamine. The destabilizing effect of protein-protein interactions, as monitored on 50-layer-thick films, is most evident at a relative humidity of 75%. Stabilizing agents were incorporated to attenuate the deleterious effects of protein aggregation. Among them, the most effective in preserving a more native-like structure are the disaccharides sucrose and trehalose in dry films and the polymer dextran in wet films. Interestingly, the polymer was found to achieve maximum efficacy at sensibly lower additive/protein ratios than the sugars.  相似文献   

19.
Molecular mobility modulates the chemical and physical stability of amorphous biomaterials. This study used steady-state and time-resolved phosphorescence of erythrosin B to monitor mobility in thin films of amorphous solid sucrose as a function of temperature. The phosphorescence intensity (lifetime), emission energy, and red-edge excitation effect were all sensitive to localized molecular mobility on the microsecond timescale in the glass and to more global modes of mobility activated at the glass transition. Blue shifts in the emission spectrum with time after excitation and systematic variations in the phosphorescence lifetime with wavelength indicated that emission originates from multiple sites ranging from short lifetime species with red-shifted emission spectrum to long lifetime species with blue-shifted emission spectrum; the activation energy for nonradiative decay of the triplet state was considerably larger for the blue-emitting species in both the glass and the melt. This study illustrates that phosphorescence from erythrosin B is sensitive both to local dipolar relaxations in the glass as well as more global relaxations in the sucrose melt and provides evidence of the value of phosphorescence as a probe of dynamic site heterogeneity as well as overall molecular mobility in amorphous biomaterials.  相似文献   

20.
Most commercially available optical oxygen sensors target the measuring range of 300 to 2 μmol L-1. However these are not suitable for investigating the nanomolar range which is relevant for many important environmental situations. We therefore developed a miniaturized phase fluorimeter based measurement system called the LUMOS (Luminescence Measuring Oxygen Sensor). It consists of a readout device and specialized “sensing chemistry” that relies on commercially available components. The sensor material is based on palladium(II)-5,10,15,20-tetrakis-(2,3,4,5,6-pentafluorphenyl)-porphyrin embedded in a Hyflon AD 60 polymer matrix and has a KSV of 6.25 x 10-3 ppmv-1. The applicable measurement range is from 1000 nM down to a detection limit of 0.5 nM. A second sensor material based on the platinum(II) analogue of the porphyrin is spectrally compatible with the readout device and has a measurement range of 20 μM down to 10 nM. The LUMOS device is a dedicated system optimized for a high signal to noise ratio, but in principle any phase flourimeter can be adapted to act as a readout device for the highly sensitive and robust sensing chemistry. Vise versa, the LUMOS fluorimeter can be used for read out of less sensitive optical oxygen sensors based on the same or similar indicator dyes, for example for monitoring oxygen at physiological conditions. The presented sensor system exhibits lower noise, higher resolution and higher sensitivity than the electrochemical STOX sensor previously used to measure nanomolar oxygen concentrations. Oxygen contamination in common sample containers has been investigated and microbial or enzymatic oxygen consumption at nanomolar concentrations is presented.  相似文献   