首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A xanthine oxidase enzyme electrode (xanthine oxidase immobilized on electrochemically modified graphite and conveniently coated with gelatine electrode working surface) for quantitative analysis of xanthine is proposed. The detection of thus developed electrochemical system is based on the electroreduction of hydrogen peroxide generated in enzyme layer and offered L-ascorbic and uric acid reducing interference effect on the substrate determination. At a working potential -50 mV (vs. Ag/AgCl) the detection limit of 4.5 microM and the linearity of the amperometric signal up to substrate concentration of about 40 microM were found. At that working potential, the electrode is practically inert towards L-ascorbic- and uric acid present. The response time did not exceed 2 min.  相似文献   

2.
A micro-biosensor was constructed by incorporating the organic conducting salt tetrathiafulvalene-tetracyanoquinodimethane (TTF-TCNQ) into a platinized platinum (Pt) wire and further covering with the electrochemical polymerical heteropolypyrrole film, in which glucose oxidase (GOx) was entrapped. The enzyme electrode can sensitively determine glucose at a low working potential, mainly based on the oxidation of H2O2. The incorporated TTF-TCNQ can significantly improve the oxidation of H2O2 on the electrode, although a part of the TTF-TCNQ functions as a mediator. Compared with the same electrode prepared without TTF-TCNQ incorporated, the TTF-TCNQ modified electrode had better performance characteristics at a working potential of 200 mV (versus SCE). The response time to 90% of the steady value was shortened from about 40 s to less than 10 s, the lower limit of the linear response was greatly extended from about 1.6 mM to 10 microM, the linear range was shifted from 1.6-10.0 to 0.01-5 mM and the sensitivity was increased from about 1 to 1.5 microA/mM. The electrode was quite stable. For continuous operation, the electrode could work for about 5 weeks and only lost 60% of its original sensitivity. Stored at 4 degrees C for intermittent determinations, the electrode kept 80% sensitivity for over 6 months. Due to covering the electrode with a non-conductive heteropolypyrrole film, ascorbate, urate and 4-acetamidophenol caused only negligible current response at an applied potential of 200 mV.  相似文献   

3.
A competitive binding nonseparation electrochemical enzyme immunoassay (NEEIA) is described for the determination of microcystin-LR (MCLR) using a double-sided microporous gold electrode in cartridge-type cells. A gold film sputtered on one side of porous nylon membrane constitutes a working electrode, while another gold film formed on the opposite side serves as a pseudo reference electrode. After immobilizing MCLR antibody on working electrode by physical adsorption, the double-sided electrode was placed simply in a diffusion U-type or within a dry strip-type cell with a conjugate pad pre-loaded with a glucose oxidase labeled MCLR (GOx-MCLR) on working electrode side. Assays were performed in two steps: an MCLR-containing sample mixed with a known amount of GOx-MCLR conjugate either in buffer solution or in pre-loaded dry pad was incubated for an appropriate period (about 10 min) to induce competitive reaction with an immobilized anti-MCLR antibody on working electrode, and a fixed concentration of glucose solution (substrate) was then added to the backside of the working electrode. Due to the competitive nature of the assay, enzymatically generated product, hydrogen peroxide (H2O2), was detected at the working gold electrode (at +800 mV versus Au) by oxidation, and the magnitude of amperometric current was inversely proportional to the concentration of MCLR in the sample. The response time after substrate addition was about 30s. Mean recovery of MCLR added to tap water was 93.5%, with a coefficient of variation (CV) of 6.6%. The proposed competitive NEEIA system is in general comparable to existing heterogeneous enzyme immunoassays with a similar detection limit (100 pg/mL MCLR), and suitable for developing a disposable type biosensor for on-site monitoring of environment.  相似文献   

4.
Xanthine oxidase (E. C. 1.2.3.2) was immobilized by adsorption on electrochemically modified graphite plate to obtain an enzyme electrode. The current of the enzyme electrode in substrate (xanthine) solutions was found to be a result of the electrooxidation of H2O2 generated in the enzyme layer. The linearity of the amperometric signal was up to a substrate concentration of 65 microM at 0.6 V (vs. Ag/AgCl). The response time was 2 minutes. The enzyme electrode preserves 80% of its initial activity after a three-week storage in air at room temperature.  相似文献   

5.
A new enzyme electrode for the determination of alcohols was developed by immobilizing alcohol oxidase in polvinylferrocenium matrix coated on a Pt electrode surface. The amperometric response due to the electrooxidation of enzymatically generated H(2)O(2) was measured at a constant potential of +0.70 V versus SCE. The effects of substrate, buffer and enzyme concentrations, pH and temperature on the response of the electrode were investigated. The optimum pH was found to be pH 8.0 at 30 degrees C. The steady-state current of this enzyme electrode was reproducible within +/-5.0% of the relative error. The sensitivity of the enzyme electrode decreased in the following order: methanol>ethanol>n-butanol>benzyl alcohol. The linear response was observed up to 3.7 mM for methanol, 3.0 mM for ethanol, 6.2 mM for n-butanol, and 5.2 mM for benzyl alcohol. The apparent Michaelis-Menten constant (K(Mapp)) value and the activation energy, E(a), of this immobilized enzyme system were found to be 5.78 mM and 38.07 kJ/mol for methanol, respectively.  相似文献   

6.
A simple method of enzyme immobilization was investigated, which is useful for development of enzyme electrodes based on polyvinylferrocenium perchlorate coated Pt electrode surface. Enzymes were incorporated into the polymer matrix via ion exchange process by immersing polyvinylferrocenium perchlorate coated Pt electrode in enzyme solution for several times. Choline and acetylcholine enzyme electrodes were developed by co-immobilizing choline oxidase and acetylcholinesterase in polyvinylferrocenium perchlorate matrix coated on a Pt electrode surface. The amperometric responses of the enzyme electrodes were measured at +0.70 V versus SCE, which was due to the electrooxidation of enzymatically produced H2O2. The effects of the thickness of the polymeric film, pH, temperature, substrate and enzyme concentrations on the response of the enzyme electrode were investigated. The optimum pH was found to be pH 7.4 at 25 degrees C. The steady-state current of these enzyme electrodes were reproducible within +/-5.0% of the relative error. Response time was found to be 30-50s and upper limit of the linear working portions was found to be 1.2mM choline and acetylcholine concentrations in which produced detectable currents were 1.0 x 10(-6)M substrate concentrations. The apparent Michaelis-Menten constant and the activation energy of this immobilized enzyme system were found to be 1.74 mM acetylcholine and 14.9 kJ mol(-1), respectively. The effects of interferents and stability of the enzyme electrodes were also investigated.  相似文献   

7.
The preparations and performances of the novel amperometric biosensors for glucose based on immobilized glucose oxidase (GOD) on modified Pt electrodes are described. Two types of modified electrodes for the enzyme immobilization were used in this study, polyvinylferrocene (PVF) coated Pt electrode and gold deposited PVF coated Pt electrode. A simple method for the immobilization of GOD enzyme on the modified electrodes was described. The enzyme electrodes developed in this study were called as PVF-GOD enzyme electrode and PVF-Au-GOD enzyme electrode, respectively. The amperometric responses of the enzyme electrodes were measured at constant potential, which was due to the electrooxidation of enzymatically produced H2O2. The electrocatalytic effects of the polymer, PVF, and the gold particles towards the electrooxidation of the enzymatically generated H2O2 offers sensitive and selective monitoring of glucose. The biosensor based on PVF-Au-GOD electrode has 6.6 times larger maximum current, 3.8 times higher sensitivity and 1.6 times larger linear working portion than those of the biosensor based on PVF-GOD electrode. The effects of the applied potential, the thickness of the polymeric film, the amount of the immobilized enzyme, pH, the amount of the deposited Au, temperature and substrate concentration on the responses of the biosensors were investigated. The optimum pH was found to be pH 7.4 at 25 degrees C. Finally the effects of interferents, stability of the biosensors and applicability to serum analysis of the biosensor were also investigated.  相似文献   

8.
Laccase purified from Ganoderma sp. was immobilized covalently onto electrochemically deposited silver nanoparticles (AgNPs)/carboxylated multiwalled carbon nanotubes (cMWCNT)/polyaniline (PANI) layer on the surface of gold (Au) electrode. A polyphenol biosensor was fabricated using this enzyme electrode (laccase/AgNPs/cMWCNT/PANI/Au electrode) as the working electrode, Ag/AgCl as the reference electrode, and platinum (Pt) wire as the auxiliary electrode connected through a potentiostat. The biosensor showed optimal response at pH 5.5 (0.1 M acetate buffer) and 35 °C when operated at a scan rate of 50 mV s−1. Linear range, response time, and detection limit were 0.1–500 μM, 6 s, and 0.1 μM, respectively. The sensor was employed for the determination of total phenolic content in tea, alcoholic beverages, and pharmaceutical formulations. The enzyme electrode was used 200 times over a period of 4 months when stored at 4 °C. The biosensor has an advantage over earlier enzyme sensors in that it has no leakage of enzyme during reuse and is unaffected by the external environment due to the protective PANI microenvironment.  相似文献   

9.
An enzyme electrode for the specific determination of catechol was developed by using catechol oxidase (EC 1.10.3.1) from eggplant (Solanum melangena L.) in combination with a dissolved oxygen probe. Optimization studies of the prepared catechol oxidase enzyme electrode established a phosphate buffer 50 mM at pH 7.0 and 35°C to provide the optimum conditions for affirmative electrode response. The enzyme electrode response depended linearly on a catechol concentration range of 5?10-7-30?10-5 M with a response time of 25 sec and substrate specificity of the catechol oxidase electrode of 100%. The biosensor retained its enzyme activity for at least 70 days.  相似文献   

10.
An amperometric enzyme electrode for the determination of glucose under anaerobic solution conditions was developed by immobilizing glucose oxidase and then by adsorbing ferrocene in polyvinylferrocenium matrix coated on a Pt electrode surface. The amperometric response due to the electrooxidation of ferrocene that the reduced flavin adenine dinucleotide centers of glucose oxidase was measured at a constant potential. The response characteristics of the enzyme electrode were investigated. The effects of the thickness of the polymeric film, the amount of the enzyme immobilized, the amount of the mediator, the glucose concentration, the applied potential, operating pH and temperature on the response of the enzyme electrode were studied. The response time and the optimum pH were found to be 30-40 s and pH 7.4 at 25 degrees C, respectively. The linear response was observed up to 5.0 mM glucose concentration that the produced detectable current was 0.0075 mM glucose concentration. The activation energy (E(a)) of immobilized enzyme reaction was calculated to be 41.3 kJ mol(-1) from the Arrhenius plot. The apparent Michaelis-Menten constant (K(Mapp)) was found to be 6.05 mM glucose according to the Lineweaver-Burk graph of the Michaelis-Menten equation under the optimum conditions. The interference signal due to the most common electrochemical interfering species was also evaluated.  相似文献   

11.
The electrocatalytic reduction of H2O2 was studied for carbonaceous electrodes modified with horse-radish peroxidase (HRP), microperoxidase (MP), and lactoperoxidase (LP). The carbonaceous electrodes were of three different graphites, carbon and glassy carbon. The peroxidase modified electrode was inserted as the working electrode in a flow through amperometric cell of the wall jet type and connected to a flow injection system. The effect of different pretreatments of the electrode surface prior to adsorption of the enzyme was investigated. Heating the electrodes in a muffle furnace at 700°C for 1.5 min was found to yield the highest currents. The electrocatalytic current for HRP-modified electrodes starts at about +600 mV vs. Ag/AgCl (pH 7.0) and reaches a maximum value at about −200 mV. For MP- and LP-modified electrodes the currents start at a lower potential (≈ 300 mV). For the best electrode material for HRP, straight calibration curves were obtained between 1 and 500 μM H2O2 at 0 mV. The mechanism for the electron transfer from the electrode to the adsorbed peroxidase is discussed. Deliberate modification of the electrode surface with quinoid type electroactive species was found to mediate the reaction. It is proposed that spontaneously occurring electrochemically active surface groups mediate the electron transfer to the adsorbed enzyme. However, a contribution to the observed current from a direct electron transfer cannot be ruled out.  相似文献   

12.
The response characteristics of a new enzyme electrode for determining choline are reported. The enzyme electrode consists of a polyvinylferrocenium perchlorate coated Pt surface onto which the enzyme, choline oxidase, is attached. Choline oxidase catalyzes the oxidation of choline to betaine, producing H2O2. Current due to H2O2 oxidation catalyzed by polyvinylferrocenium centers was measured. The effects of choline concentration, the amount of enzyme immobilized and the operating pH and temperature on the response of the enzyme electrode were studied. The effects of interferents were also investigated. The response time was found to be 60–70 s and the upper limit of the linear working portion was found to be 1.2 mM choline concentration. The minimum substrate concentration that produced detectable current was 4.0×10−6 M choline concentration. The steady-state current of this enzyme electrode was reproducible within ±4.6% of relative error. The apparent Michaelis–Menten constant (KMapp) and the activation energy, Ea, of this immobilized enzyme system were found to be 2.32 mM and 38.91 kJ/mol, respectively.  相似文献   

13.
Indirectly heated electrodes operating in a non-isothermal mode have been used as transducers for reagentless glucose biosensors. Pyrroloquinoline quinone-dependent soluble glucose dehydrogenase (PQQ-sGDH) was entrapped on the electrode surface within a redox hydrogel layer. Localized polymer film precipitation was invoked by electrochemically modulating the pH-value in the diffusion zone in front of the electrode. The resulting decrease in solubility of an anodic electrodeposition paint (EDP) functionalized with Osmium complexes leads to precipitation of the redox hydrogel concomitantly entrapping the enzyme. The resulting sensor architecture enables a fast electron transfer between enzyme and electrode surface. The glucose sensor was operated at pre-defined temperatures using a multiple current-pulse mode allowing reproducible indirect heating of the sensor. The sensor characteristics such as the apparent Michaelis constants K(M)(app) and maximum currents I(max)(app) were determined at different temperatures for the main substrate glucose as well as a potential interfering co-substrate maltose. The limit of detection increased with higher temperatures for both substrates (0.020 mM for glucose, and 0.023 mM for maltose at 48 degrees C). The substrate specificity of PQQ-sGDH is highly temperature dependent. Therefore, a mathematical model based on a multiple linear regression approach could be applied to discriminate between the current response for glucose and maltose. This allowed accurate determination of glucose in a concentration range of 0-0.1mM in the presence of unknown maltose concentrations ranging from 0 to 0.04 mM.  相似文献   

14.
A potentiometric enzyme electrode for the direct measurement of organophosphate (OP) nerve agents was developed. The basic element of this enzyme electrode was a pH electrode modified with an immobilized organophosphorus hydrolase (OPH) layer formed by cross-linking OPH with bovine serum albumin (BSA) and glutaradehyde. OPH catalyses the hydrolysis of organophosphorus pesticides to release protons, the concentration of which is proportional to the amount of hydrolysed substrate. The sensor signal and response time was optimized with respect to the buffer pH, ionic concentration of buffer, temperature, and units of OPH immobilized using paraoxon as substrate. The best sensitivity and response time were obtained using a sensor constructed with 500 IU of OPH and operating in pH 8.5, 1 mM HEPES buffer. Using these conditions, the biosensor was used to measure as low as 2 microM of paraoxon, ethyl parathion, methyl parathion and diazinon. The biosensor was completely stable for at least one month when stored in pH 8.5, 1 mM HEPES + 100 mM NaCl buffer at 4 degrees C.  相似文献   

15.
The aim of the present work is to design an electrode for biosensors by covalent immobilization of the redox enzyme. In the covalently modified electrode, the biocatalyst is located close to the electrode surface and this is expected to enhance the electron transfer rate from the enzyme to the electrode. Several methods of covalent immobilization of enzymes onto a glassy carbon surface are described. We have chosen horse radish peroxidase enzyme in our study but any other suitable enzyme can be immobilized depending on the intended use. A three step procedure that includes (i) heat treatment of matrix at l00-l10°C to remove volatiles and absorbates, (ii) chemjcal pretreatment to introduce functional groups like -OH, -NO2, -Br etc. followed by (iii) glutaraldehyde coupling of the enzyme (for the nitrated matix after subsequent reduction) or modification of the matrix by carboxymethylation and enzyme coupling using carbodiimide (for hydroxylated matrix) was followed. The amount of enzyme immobilized onto the carbon surface was estimated by spectrophotometric enzymatic activity assay, commonly used for the soluble enzyme. We found that simple nitration did not introduce any significant amount of functional groups and the matrix with hydrogen peroxide pretreatment showed the highest enzyme loading of 0.05 U/mg of carbon matrix. The HRP enzyme electrode was tested in a rotating disk experiment for its response with the substrate.  相似文献   

16.
Amperometric glucose biosensors have been developed based on entrapment on platinum (Pt) electrode using cyclic voltammetry technique in glucose oxidase (GOD) and pyrrole containing p-toluenesulfonic acid (pTSA) or sodium p-toluenesulfonate (NapTS) as supporting electrolyte solutions. Both of electrolyte solutions were suitable media for the formation and deposition of polypyrrole-GOD (PPy-GOD) layers on Pt substrate. Pt/PPy-GOD electrodes brought about in different morphological properties as well as different electrochemical and biochemical response. The highest responses obtained in pTSA and NapTS electrolytes were observed at pH of 4.5 and 7.0 for Pt/PPy-GOD electrodes, respectively. While linearity was observed between 0.0-1.0 mM glucose substrate for both electrodes, I(max) value of Pt/PPy-GOD(NapTS) electrode was approximately twice as high as that of Pt/PPy-GOD(pTSA) electrode as 25.4 and 14.2 microA, respectively. Five commercial drinks were tested with enzyme electrodes and compared with results obtained spectrophotometrically using glucose kit. Results revealed that Pt/PPy-GOD(NapTS) electrode exhibited better biosensor response.  相似文献   

17.
A new zinc oxide nanoparticles/chitosan/carboxylated multiwall carbonnanotube/polyaniline (ZnO-NPs/CHIT/c-MWCNT/PANI) composite film has been synthesized on platinum (Pt) electrode using electrochemical techniques. Three enzymes, creatinine amidohydrolase (CA), creatine amidinohydrolase (CI) and sarcosine oxidase (SO) were immobilized on ZnO-NPs/CHIT/c-MWCNT/PANI/Pt electrode to construct the creatinine biosensor. The enzyme electrode was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy and electrochemical impedance spectroscopy (EIS). The enzyme electrode detects creatinine level as low as 0.5 μM at a signal to noise ratio of 3 within 10s at pH 7.5 and 30°C. The fabricated creatinine biosensor showed linear working range of 10-650 μM creatinine with a sensitivity of 0.030 μA μM(-1)cm(-2). The biosensor shows only 15% loss of its initial response over a period of 120 days when stored at 4°C. The fabricated biosensor was successfully employed for determination of creatinine in human blood serum.  相似文献   

18.
A mixture of commercial creatinine amidohydrolase (CA), creatine amidinohydrolase (CI), and sarcosine oxidase (SO) was coimmobilized covalently via N-ethyl-N′-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS) chemistry onto carboxylated multiwalled carbon nanotube (c-MWCNT)/polyaniline (PANI) nanocomposite film electrodeposited over the surface of a platinum (Pt) electrode. A creatinine biosensor was fabricated using enzyme/c-MWCNT/PANI/Pt as working electrode, Ag/AgCl as reference electrode, and Pt wire as auxiliary electrode connected through potentiostat. The enzyme electrode was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, and electrochemical impedance spectroscopy (EIS). The biosensor detected creatinine levels as low as 0.1 μM, estimated at a signal-to-noise ratio of 3, within 5 s at pH 7.5 and 35 °C. The optimized biosensor showed a linear response range of 10 to 750 μM creatinine with sensitivity of 40 μA/mM/cm2. The fabricated biosensor was successfully employed for determination of creatinine in human serum. The biosensor showed only 15% loss in its initial response after 180 days when stored at 4 °C.  相似文献   

19.
Lysine decarboxylase (L-lysine carboxylyase, E.C.4.1.1.18) is immobolized on a carbon dioxide gas-sensing electrode, by copolymerization with gelatin using the bifuncitional agent glutaraldehyde. The enzyme electrodes thus prepared are used in a continuous flow system to measure the concentration of L-lysine in a mixture of amino acids. The measuring time for each sample is about 3 min, including response and rinsing times. The electrode response is linear between 0.01-1 g/L and has a high specificity for L-lysine. The enzyme electrode response to lysine at concentrations below 0.5 g/L is stable on repeated use for at least 500 assays.  相似文献   

20.
A new silver nanoparticles (AgNPs)/carboxylated multiwalled carbon nanotubes (c-MWCNT)/polyaniline (PANI) film has been synthesized on Au electrode using electrochemical techniques. The enzyme glutathione oxidase (GSHOx) (EC 1.8.3.3) was immobilized covalently on the surface of AgNPs/c-MWCNT/PANI/Au electrode to construct the glutathione biosensor. The modified electrode was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and Fourier transform infrared (FTIR) spectrophotometry. The biosensor showed optimum response within 4s at +0.4V vs. Ag/AgCl, pH 6.0 and 35 °C, with a linear working range of 0.3-3500 μM and a detection limit of 0.3 μM. The glutathione biosensor was employed for measurement of glutathione content in hemolysated erythrocyte (RBC). The sensor was evaluated with 97.77% and 99.16% recovery of added glutathione in hemolysated RBC and 2.4% and 6.3% within and between batch coefficients of variation (CVs) respectively. The enzyme electrode lost 50% of its initial activity after 300 uses over a period of 3 months, when stored at 4 °C. The biosensor has the advantages over earlier biosensors in terms of greater stability, lower response time and no interference by a number of RBC hemolysate substances.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号