首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Quartz has a dissipation factor of approximately 10(-4), which is an order of magnitude less than that of the best glasses previously used to fabricate patch pipettes; it's dielectric constant of 3.8 is also lower than that of other glasses. On the basis of these electrical characteristics it is expected that patch pipettes pulled from quartz tubing will produce significantly less noise than pipettes made from other glasses. Our work confirms these expectations and we describe theoretical and practical aspects of the use of quartz pipettes for single channel patch voltage clamp measurements. Methods for pulling quartz pipettes with a laser-based puller and coating them with low-loss elastomers are discussed, as are precautions that are necessary to achieve low noise recordings. We have shown that quartz pipettes can be pulled from tubing with outer diameter to inner diameter ratios as large as 3 and a method of applying heavy elastomer coatings all the way to the tip of pipettes is presented. Noise sources arising from the pipette and its holder are described theoretically, and it is shown that measured noise is in good agreement with such predictions. With low noise capacitive feedback electronics, small geometry holders, and thick-walled quartz pipettes coated with low-loss elastomers we have been routinely able to achieve noise of 100 fA rms or less in a 5-kHz bandwidth with real cell patches and a pipette immersion depth of approximately 2 mm. On occasion we have achieved noise as low as 60 fA rms in this bandwidth.  相似文献   

2.
A variant of the whole-cell patch clamp technique is described which allows measurement of whole-cell ionic currents in small cells while minimizing cell dialysis with the pipette solution. The technique involves the application of negative pressure to the inside of small (less than 1 micron) tip diameter pipettes placed on the cell surface to achieve high resistance seals and membrane rupture. The technique has been used successfully in a variety of different types of cells to study membrane currents carried by Ca and K, currents generated by exchange carriers as well as electrical coupling between cells. Overall, the technique seems well suited for the study of ionic currents in small cells, and provides an alternative to conventional patch clamping techniques which necessitate intracellular dialysis.  相似文献   

3.
A novel concentric design of double-barrelled Ca2+-selective microelectrode, with an inner pipette tip that protrudes beyond an outer one, has recently been developed and is described. This configuration of pipettes was produced from concentric capillaries in one step using a horizontal pipette puller. For the tip of the inner barrel to protrude, Corning 1724 aluminosilicate glass was selected, as it has a higher melting point than the 1723 glass which is used for the outer barrel. To reduce electrode resistance the inner capillary was best made with a triangular shape. It was preferentially silanized in a dry box by injection of methyltrichlorosilane into only the inner barrel. The Ca2+ neutral carrier-based liquid membrane (ETH 1001) was back-filled from the tip to the shank of the inner pipette and above this CaCl2 solution was added. KCl, which contained EGTA and was buffered to pCa 7, was used to fill the reference barrel. These Ca2+ electrodes showed linear response with slope approximately equal to 30 mV for changes in Ca2+ concentration between 10(-3) and 10(-7) M in the presence of constant [K+]. They offer a number of advantages including a low noise level achieved by the presence of the external concentric KCl electrode, and a simple mechanical structure that allows applications to a variety of small cells.  相似文献   

4.
We have developed techniques for studying patch-clamped membranes inside glass pipettes using high voltage electron microscopy (HVEM). To preserve the patch structure with the least possible distortion, we rapidly froze and freeze dried the pipette tip. The pipette is transparent for more than 50 microns from the tip. HVEM images of patches confirm light microscopy observations that the patch is not a bare bilayer, but a membrane-covered bleb of cytoplasm that may include organelles and cytoskeleton. The membrane that spans the pipette is commonly tens of micrometers from the tip of the pipette and occasionally as far as 100 microns. The structure of patches taken from a single cell type is variable but there are consistent differences between patches made from different cell types. With suction applied to the pipette before seal formation, we have seen in the light microscope vesicles swept from the plasmalemma up the pipette. These vesicles are visible in electron micrographs, particularly those made from chick cardiac muscle. Colloidal gold labeling of the patch permitted identification of lectin-binding sites and acetylcholine receptors. In young cultures of Xenopus myocytes, the receptors were diffuse. In 1-wk-old cultures, the receptors formed densely packed arrays. The patch pipette can serve, not only as a recording device, but as a tool for sampling discrete regions of the cell surface. Because the pipette has a constant path length for axial rotation, it is a unique specimen holder for microtomography. We have made preliminary tomographic reconstructions of a patch from Xenopus oocyte.  相似文献   

5.
Pressure-polishing is a method for shaping glass pipettes for patch-clamp recording. We first developed this method for fabricating pipettes suitable for recording from small (<3 m) neuronal cell bodies. The basic principal is similar to glass-blowing and combines air pressure and heat to modify the shape of patch pipettes prepared by a conventional micropipette puller. It can be applied to so-called soft (soda lime) and hard (borosilicate) glasses. Generally speaking, pressure polishing can reduce pipette resistance by 25% without decreasing the diameter of the tip opening (Goodman and Lockery, 2000). It can be applied to virtually any type of glass and requires only the addition of a high-pressure valve and fitting to a microforge. This technique is essential for recording from ultrasmall cells (<5 m) and can also improve single-channel recording by minimizing pipette resistance. The blunt shape is also useful for perforated-patch clamp recording since this tip shape results in a larger membrane bleb available for perforation.Download video file.(62M, mp4)  相似文献   

6.
Whole cell patch clamp recording performed on a planar glass chip   总被引:6,自引:0,他引:6       下载免费PDF全文
The state of the art technology for the study of ion channels is the patch clamp technique. Ion channels mediate electrical current flow, have crucial roles in cellular physiology, and are important drug targets. The most popular (whole cell) variant of the technique detects the ensemble current over the entire cell membrane. Patch clamping is still a laborious process, requiring a skilled experimenter to micromanipulate a glass pipette under a microscope to record from one cell at a time. Here we report on a planar, microstructured quartz chip for whole cell patch clamp measurements without micromanipulation or visual control. A quartz substrate of 200 microm thickness is perforated by wet etching techniques resulting in apertures with diameters of approximately 1 microm. The apertures replace the tip of glass pipettes commonly used for patch clamp recording. Cells are positioned onto the apertures from suspension by application of suction. Whole cell recordings from different cell types (CHO, N1E-115 neuroblastoma) are performed with microstructured chips studying K(+) channels and voltage gated Ca(2+) channels.  相似文献   

7.
Summary A variant of the whole-cell patch clamp technique is described which allows measurement of whole-cell ionic currents in small cells while minimizing cell dialysis with the pipette solution. The technique involves the application of negative pressure to the inside of small (< 1 µm) tip diameter pipettes placed on the cell surface to achieve high resistance seals and membrane rupture. The technique has been used successfully in a variety of different types of cells to study membrane currents carried by Ca and K, currents generated by exchange carriers as well as electrical coupling between cells. Overall, the technique seems well suited for the study of ionic currents in small cells, and provides an alternative to conventional patch clamping techniques which necessitate intracellular dialysis.  相似文献   

8.
The phototransduction enzymatic cascade in cones is less understood than in rods, and the zebrafish is an ideal model with which to investigate vertebrate and human vision. Therefore, here, for the first time, the zebrafish green cone photoresponse is characterized also to obtain a firm basis for evaluating how it is modulated by exogenous molecules. To this aim, a powerful method was developed to obtain long-lasting recordings with low access resistance, employing pressure-polished patch pipettes. This method also enabled fast, efficient delivery of molecules via a perfusion system coupled with pulled quartz or plastic perfusion tubes, inserted very close to the enlarged pipette tip. Sub-saturating flashes elicited responses in different cells with similar rising phase kinetics but with very different recovery kinetics, suggesting the existence of physiologically distinct cones having different Ca2+ dynamics. Theoretical considerations demonstrate that the different recovery kinetics can be modelled by simulating changes in the Ca2+-buffering capacity of the outer segment. Importantly, the Ca2+-buffer action preserves the fast response rising phase, when the Ca2+-dependent negative feedback is activated by the light-induced decline in intracellular Ca2+.  相似文献   

9.
Although several pathways of bitter taste signal transduction have been proposed in taste cells, these mechanisms have not been elucidated in detail. To investigate the diversity of responses to bitter stimuli, we recorded the electrophysiological responses to quinine, denatonium and naringin using whole-cell patch clamp technique in isolated taste cells of C57BL/6J mice. Ten mM quinine induced depolarizing response under the current clamp mode, and inward current response under the voltage-clamp mode (holding potential -80 mV) using both K+ (with pseudo intracellular solution) and Cs+ (K+ was substituted by Cs+ in the pseudo intracellular solution) pipettes. However, when the K+ pipette was used, the membrane conductance was suppressed and activated in succession. On the other hand, the membrane conductance was only activated when the Cs+ pipette was used. Half to one mM denatonium induced depolarizing response under the current clamp mode, and outward current response under the voltage clamp mode with both pipettes. Using these pipettes, the membrane conductance was activated or suppressed in the individual case. Naringin-induced responses were not detected in these measurements. These electrophysiological recordings suggest that multiple transduction mechanisms are involved in bitter taste perception in mouse taste cells.  相似文献   

10.
Micropipettes as research instruments are well established in cell biology, including blood rheology. However, the experimental results are, to some extent, dependent on the quality of the pipette itself; it is usually critical to have the desired pipette internal diameter and a perpendicular tip. Pipette fabrication is a two-step procedure involving: a) the pulling of the pipette from a glass capillary; b) the trimming of the pipette tip. A common method to trim and fracture the pipette tip is the use of a melted glass bead on a heated tungsten wire. Previous devices using this method were often associated with problems because the heated wire varied in length with temperature. As a result, the bead together with the attached pipette tip moved markedly and thus hampered the possibility to obtain a perpendicularly cut pipette tip. An improved design, based on the same principle with a melted glass bead, is thus suggested; it eliminates the problem with a moving glass bead and, in addition, allows semi-automatic pipette trimming by utilizing the heat-induced elongation/retraction of the heated wire to fracture the tip without requiring manual assistance. Furthermore, a simple pipette storing technique is suggested, based on standard laboratory utensils, in order to more easily handle fragile pipettes without risk of breakage.  相似文献   

11.
To investigate the mechanism for the delayed activation by voltage of the predominant mechanosensitive (MS) channel in Xenopus oocytes, currents were recorded from on-cell and excised patches of membrane with the patch clamp technique and from intact oocytes with the two-electrode voltage clamp technique. MS channels could be activated by stretch in inside-out, on-cell, and outside-out patch configurations, using pipettes formed of either borosilicate or soft glass. In inside-out patches formed with borosilicate glass pipettes, depolarizing voltage steps activated MS channels in a cooperative manner after delays of seconds. This voltage-dependent activation was not observed for outside-out patches. Voltage-dependent activation was also not observed when the borosilicate pipettes were either replaced with soft glass pipettes or coated with soft glass. When depolarizing voltage steps were applied to the whole oocyte with a two-electrode voltage clamp, currents that could be attributed to MS channels were not observed. Yet the same depolarizing steps activated MS channels in on-cell patches formed with borosilicate pipettes on the same oocyte. These observations suggest that the delayed cooperative activation of MS channels by depolarization is not an intrinsic property of the channels, but requires interaction between the membrane and patch pipette.  相似文献   

12.
Lipid-glass adhesion in giga-sealed patch-clamped membranes.   总被引:5,自引:0,他引:5       下载免费PDF全文
Adhesion between patch-clamped lipid membranes and glass micropipettes is measured by high contrast video imaging of the mechanical response to the application of suction pressure across the patch. The free patch of membrane reversibly alters both its contact angle and radius of curvature on pressure changes. The assumption that an adhesive force between the membrane and the pipette can sustain normal tension up to a maximum Ta at the edge of the free patch accounts for the observed mechanical responses. When the normal component of the pressure-induced membrane tension exceeds Ta membrane at the contact point between the free patch and the lipid-glass interface is pulled away from the pipette wall, resulting in a decreased radius of curvature for the patch and an increased contact angle. Measurements of the membrane radius of curvature as a function of the suction pressure and pipette radius determine line adhesion tensions Ta which range from 0.5 to 4.0 dyn/cm. Similar behavior of patch-clamped cell membranes implies similar adhesion mechanics.  相似文献   

13.
We present a simplified model to identify and analyze the important variables governing the diffusion of substances from pipettes into canine cardiac Purkinje cells in the whole cell patch clamp configuration. We show that diffusion of substances through the pipette is the major barrier for equilibration of the pipette and cellular contents. We solve numerically the one-dimensional diffusion equation for different pipette geometries, and we derive a simple analytic equation which allows one to estimate the time necessary to reach the steady state of intracellular concentration. The time constant of the transient to steady state is given by a pipette geometric factor times the cell volume divided by the diffusion coefficient of the substance of interest. The geometric factor is shown to be given by the ratio of pipette resistance to the resistivity of the filling solution. Additionally from our modeling, we concluded that pipette perfusion at distances greater than 20 microns from the pipette tip would not substantially reduce the time necessary to achieve the steady state.  相似文献   

14.
通过膜片钳玻璃微电极内插管进行胞内透析   总被引:5,自引:0,他引:5  
Li GH  Li ZW  Wang SD  Wei JB  Zheng XK 《生理学报》2002,54(2):179-182
本文介绍一种膜片钳微电极内插管进行胞内透析的方法。利用通用的微电极夹持器在其抽吸负压的侧管上方钻一斜孔直通夹持器中央管腔。插入微量移液管头拉制成的细管(外径约0.1mm),后者与Ag-AgCl电极一起伸出夹持器口端。通过相连的注射器,可以很方便地进行电极内液置换及胞内药物透析,此法和二次钳压技术及国外介绍的微插管电极内液置换相比,更加简便易行,结果更可靠。  相似文献   

15.
Efforts to develop novel methods for recording from ion channels have been receiving increased attention in recent years. In this study, the authors report a unique "inside-out" whole-cell configuration of patch-clamp recording that has been developed. This method entails adding cells into a standard patch pipette and, with positive pressure, obtaining a gigaseal recording from a cell at the inside tip of the electrode. In this configuration, the cell may be moved through the air, first rupturing part of the cellular membrane and enabling bath access to the intracellular side of the membrane, and then into a series of wells containing differing solutions, enabling robotic control of all the steps in an experiment. The robotic system developed here fully automates the electrophysiological experiments, including gigaseal formation, obtaining whole-cell configuration, data acquisition, and drug application. Proof-of-principle experiments consisting of application of intracellularly acting potassium channel blockers to K+ channel cell lines resulted in a very rapid block, as well as block reversal, of the current. This technique allows compound application directly to the intracellular side of ion channels and enables the dissociation of compound in activities due to cellular barrier limitations. This technique should allow for parallel implementation of recording pipettes and the future development of larger array-based screening methods.  相似文献   

16.
We have developed techniques for micromanipulation under high power video microscopy. We have used these to study the structure and motion of patch-clamped membranes when driven by pressure steps. Patch-clamped membranes do not consist of just a membrane, but rather a plug of membrane-covered cytoplasm. There are organelles and vesicles within the cytoplasm in the pipette tip of both cell-attached and excised patches. The cytoplasm is capable of active contraction normal to the plane of the membrane. With suction applied before seal formation, vesicles may be swept from the cell surface by shear stress generated from the flow of saline over the cell surface. In this case, patch recordings are made from membrane that was not originally present under the tip. The vesicles may break, or fuse and break, to form the gigasealed patch. Patch membranes adhere strongly to the wall of the pipette so that at zero transmural pressure the membranes tend to be normal to the wall. With transmural pressure gradients, the membranes generally become spherical; the radius of curvature decreasing with increasing pressure. Some patches have nonuniform curvature demonstrating that forces normal to the membrane may be significant. Membranes often do not respond quickly to changes in pipette pressure, probably because viscoelastic cytoplasm reduces the rate of flow through the tip of the pipette. Inside-out patches may be peeled from the walls of the pipette, and even everted (with positive pressure), without losing the seal. This suggests that the gigaseal is a distributed property of the membrane-glass interface.  相似文献   

17.
Glass microelectrodes (also called pipettes) have been a workhorse of electrophysiology for decades. Today, such pipettes are made from glass capillaries using a programmable puller. Such instruments heat the capillary using either a metal filament or a laser and draw out the glass using gravity, a motor or both. Pipettes for patch-clamp recording are formed using only heat and gravity, while sharp electrodes for intracellular recording use a combination of heat, gravity, and a motor. The procedure used to make intracellular recording pipettes is similar to that used to make injection needles for a variety of applications, including cRNA injection into Xenopus oocytes. In general, capillary glass <1.2 mm in diameter is used to make pipettes for patch clamp recording, while narrower glass is used for intracellular recording (outer diameter = 1.0 mm). For each tool, the puller is programmed slightly differently. This video shows how to make both kinds of recording pipettes using pre-established puller programs.Download video file.(65M, mp4)  相似文献   

18.
The biophysical properties and cellular distribution of ion channels largely determine the input/output relationships of electrically excitable cells. A variety of patch pipette voltage clamp techniques are available to characterize ionic currents. However, when used by themselves, such techniques are not well suited to the task of mapping low-density channel distributions. We describe here a new voltage clamp method (the whole cell loose patch (WCLP) method) that combines whole-cell recording through a tight-seal pipette with focal extracellular stimulation through a loose-seal pipette. By moving the stimulation pipette across the cell surface and using a stationary whole-cell pipette to record the evoked patch currents, this method should be suitable for mapping channel distributions, even on large cells possessing low channel densities. When we applied this method to the study of currents in cultured chick myotubes, we found that the cell cable properties and the series resistance of the recording pipette caused significant filtering of the membrane currents, and that the filter characteristics depended in part upon the distance between the stimulating and recording pipettes. We describe here how we determined the filter impulse response for each loose-seal pipette placement and subsequently recovered accurate estimates of patch membrane current through deconvolution.  相似文献   

19.
Single unit recording from olfactory cilia.   总被引:9,自引:1,他引:8       下载免费PDF全文
Sensory cilia from olfactory receptor cells can be pulled into a patch pipette located above the mucus layer of an olfactory mucosa. While the pipette does not form a tight electrical seal with the ciliary membrane, it nevertheless allows to record current transients driven by action potentials arising in the olfactory neuron. This method is an alternative to single-unit-recording with electrodes pushed into the mucosa and, in some respects, to patch clamp recordings from isolated olfactory cells. Its advantage is technical simplicity and minimal disturbance of the neuron from which signals are derived. Less than 5% of the chemosensitive apical surface of the neuron is covered by the pipette. The neuron remains in situ and its cilia remain covered with some mucus. (However, mucus is in part dissolved by the bathing solution). Odorant thresholds in the picomolar range were thus obtained.  相似文献   

20.
We aimed to develop and validate a reliable method for stable long-term recordings of EEG activity in zebrafish, which is less prone to artifacts than current invasive techniques. EEG activity was recorded with a blunt electrolyte-filled glass pipette placed on the zebrafish head mimicking surface EEG technology in man. In addition, paralysis of agarose-embedded fish using D-tubocurarine excluded movement artifacts associated with epileptic activity. This non-invasive recording technique allowed recordings for up to one hour and produced less artifacts than impaling the zebrafish optic tectum with a patch pipette. Paralyzed fish survived, and normal heartbeat could be monitored for over 1h. Our technique allowed the demonstration of specific epileptic activity in kcnj10a morphant fish (a model for EAST syndrome) closely resembling epileptic activity induced by pentylenetetrazol. This new method documented that seizures in the zebrafish EAST model were ameliorated by pentobarbitone, but not diazepam, validating its usefulness. In conclusion, non-invasive recordings in paralyzed EAST syndrome zebrafish proved stable, reliable and robust, showing qualitatively similar frequency spectra to those obtained from pentylenetetrazol-treated fish. This technique may prove particularly useful in zebrafish epilepsy models that show infrequent or conditional seizure activity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号