首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, sensitive and reproducible method was developed for the determination of lamotrigine in whole blood with on-line solid phase extraction followed by HPLC separation with UV detection. Whole blood samples were diluted 1:1 with water and then injected directly on a clean-up column dry-packed with 40microm C8 silica and separated on a C18 reversed-phase column (150x4.6mm) at room temperature. The extraction column was activated with methanol and conditioned with phosphate buffer of pH 4.5. Mobile phases consisted of phosphate buffer of pH 4.5 for the extraction column and of phosphate buffer of pH 4.5 - acetonitrile (60:40, v/v) for the analytical column. At a flow rate of 1.0ml/min and a connection time of 1.0min, the complete cycle time was 10.0min. Detection was carried out at 260nm. No internal standard was necessary. The method was linear over concentration range 0.2-20.0microg/ml for lamotrigine. Recovery was 98%. Within-day and between-day coefficients of variation ranged from 1.8 to 6.7%.  相似文献   

2.
A simple, rapid and reproducible reversed-phase high-performance liquid chromatographic method for the simultaneous determination of benzoic acid (BA), phenylacetic acid (PAA) and their respective glycine conjugates hippuric acid (HA) and phenaceturic acid (PA) in sheep urine is described. The procedure involves only direct injection of a diluted urine sample, thus obviating the need for an extraction step or an internal standard. The compounds were separated on a Nova-Pak C18 column with isocratic elution with acetate buffer (25 mM, pH 4.5)—methanol (95:5). A flow-rate of 1.0 ml/min, a column temperature of 35°C and detection at 230 nm were employed. These conditions were optimized by investigating the effects of pH, molarity, methanol concentration in the mobile phase and column temperature on the resolution of the metabolites. The total analysis time was less than 15 min per sample. At a signal-to-noise ratio of 3 the detection limits for ten-fold diluted urine were 1.0 μg/ml for BA and HA and 5.0 μg/ml for PAA and PA with a 20-μl injection.  相似文献   

3.
A column-switching, reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of a new carbapenem antibiotic assay using ultraviolet detection has been developed for a new carbapenem antibiotic L-749,345 in human plasma and urine. A plasma sample is centrifuged and then injected onto an extraction column using 25 mM phosphate buffer, pH 6.5. After 3 min, using a column-switching valve, the analyte is back-flushed with 10.5% methanol–phosphate buffer for 3 min onto a Hypersil 5 μm C18 BDS 100×4.6 mm analytical column and then detected by absorbance at 300 nm. The sample preparation and HPLC conditions for the urine assay are similar, except for a longer analytical column 150×4.6 mm. The plasma assay is specific and linear from 0.125 to 50 μg/ml; the urine assay is linear from 1.25 to 100 μg/ml.  相似文献   

4.
An improved protocol has been developed to isolate homovanillic acid (HVA) and vanilmandelic acid (VMA) from urine with strong anion-exchange resin. The sample is diluted with acetate buffer and passed through a disposable column. HVA, uric acid, and many hydrophobic organic acids are removed with 1.0 M acetic acid—ethanol, Then VMA is eluted with 0.5 M phosphoric acid. Two isocratic mobile phases allow rapid high-performance liquid chromatographic measurement of VMA (5 min) and HVA (8 mins) on a 5-μm ODS column. Selective conditions were developed with dual-electrode coulometric detection to permit specific measurement of VMA, HVA, and internal standards, with less than 5% between-run variation.  相似文献   

5.
A new high-performance liquid chromatographic method with column switching has been developed for the simultaneous determination of metampicillin and its metabolite ampicillin in biological fluids. The plasma, urine and bile samples were injected onto a precolumn packed with LiChrosorb RP-8 (25–40 μm) after simple dilution with an internal standard solution in 0.05 M phosphate buffer (pH 7.0). The polar plasma components were washed out using 0.05 M phosphate buffer (pH 7.0). After valve switching, the concentrated drugs were eluted in the back-flush mode and separated by an Ultracarb 5 ODS-30 column with a gradient system of acetonitrile-0.02 M phosphate buffer (pH 7.0) as the mobile phase. The method showed excellent precision, accuracy and speed with a detection limit of 0.1 μg/ml. The total analysis time per sample was less than 40 min and the coefficients of variation for intra- and inter-assay were less than 5.1%. This method has been successfully applied to plasma, urine and bile samples from rats after intravenous injection of metampicillin.  相似文献   

6.
2-Oxoadipic acid, a key metabolite of tryptophan and lysine, reacted with 1,2-diamino-4,5-methylenebenzene in an acidic solution to produce a fluorescent derivative. The reaction product was separated using a Tosoh ODS-80Ts column with 20 mmol/L of KH?PO?-K?HPO? buffer (pH 7.0) containing 26% methanol at a flow rate 0.8 mL/min. The excitation wavelength of detection was 367 nm, and the emission wavelength was 446 nm. The limit of quantification was 1 pmol per injection, sufficiently sensitive for the determination of 2-oxoadipic acid in human and experimental animal urine.  相似文献   

7.
A validated, high pressure liquid chromatographic (HPLC) method for simultaneous quantitation of urinary catecholic acids 4-hydroxy-3-methoxymandelic acid (HMMA) (vanylmandelic acid) (VMA), 4-hydroxy-3-methoxyphenylacetic acid (HVA) and 5-hydroxyindole-3-acetic acid (5-HIAA) was developed. Sample preparation involved liquid–liquid extraction of acidified urine, containing iso-HMMA (IS) as internal standard, with ether, evaporation of the organic extract, followed by reconstitution of the residue in phosphate buffer at pH 3.3. After reversed-phase HPLC at 35 °C and separation on a Licrospher 125 mm × 4 mm C18 column (5 μm particle size) with phosphate buffer (pH 3.5)–acetone (950:50, v/v) as eluent, quantitation is achieved by electrochemical detection using coulometric detection at a potential of +350 mV. The method was successfully applied to routine diagnosis of neuroblastoma, carcinoid syndrome and pheochromocytoma.  相似文献   

8.
The performance of monolithic HPLC columns Chromolith (made by Merck, Germany) and conventional C18 columns Discovery (Supelco, Sigma-Aldrich, Prague, Czech Republic) was tested and the comparison for two topical preparations Ketoprofen gel and Estrogel gel was made. The composition of mobile phases - for Ketoprofen analysis a mixture of acetonitrile, water and phosphate buffer adjusted to pH 3.5 (40:58:2) and for Estrogel analysis a mixture of acetonitrile, methanol, water (23:24:53) - was usually not optimal for analyses at all types of columns. Thus an adjustment of components ratio was necessary for sufficient resolution of the compounds analysed. Various flow rates (1.0-5.0 ml/min) and mobile phases (usually increasing ratio of water content) were applied. Determination of active substances, preservatives and impurities and comparison of retention times and system suitability test parameters was accomplished. For Estrogel gel, following chromatographic conditions were found: using Chromolith Flash RP-18e monolith column, mobile phase was acetonitrile, methanol, water (13:24:63, v/v/v) and flow-rate 3.0 ml/min. Using monolith column ChromolithSpeedROD RP-18e, the mobile phase was acetonitrile, methanol, water (18:24:58, v/v/v) and flow-rate 4.0 ml/min. For the monolith column Chromolith Performance RP-18e, the mobile phase was acetonitrile, methanol, water (23:24:53, v/v/v), flow-rate 3.0ml/min. Analysis of Ketoprofen gel gave the best results using following analytical conditions: for monolith column Chromolith Flash RP-18e, mobile phase as a mixture of acetonitrile, water, phosphate buffer pH 3.5 (30:68:2, v/v/v) was used, at flow-rate 2.0 ml/min. For ChromolithSpeedROD RP-18e monolith column, acetonitrile, water, phosphate buffer pH 3.5 (35:63:2, v/v/v) was used as a mobile phase at flow-rate 3.0 ml/min. Chromolith Performance RP-18e gave the best results using mobile phase acetonitrile, water, phosphate buffer pH 3.5 (30:68:2, v/v/v) at the flow-rate 5.0 ml/min. It was proved that monolith columns, due to their porosity and low back-pressure, can save analysis time by about a factor of three with sufficient separation efficiency. Thus, for example 11 min long analysis can be performed in 4 min with comparable results.  相似文献   

9.
A simultaneous determination of vanilmandelic acid, homovanillic acid, creatinine and uric acid using capillary electrophoresis was investigated. The optimum conditions of buffer concentration, pH and surfactant concentration were studied, and high resolution was obtained using a 30 mM phosphate buffer (pH 7.0) containing 150 mM sodium dodecyl sulfate. The detection was by UV absorbance at 245 nm and the column was a fused-silica capillary of 67 cm×75 μm I.D.. The determination of these metabolites in human urine was completed within 15 min without any interferences.  相似文献   

10.
7-Fluoro-4-nitrobenzo-2-oxa-1,3-diazole is used as a precolumn fluorescent labeling reagent for high-performance liquid chromatography of amino acids, including proline and hydroxyproline. The reaction is run at pH 8.0 at 60°C for 5 min. The fluorophors (Asp, Glu, Hyp, Ser, Gly, Thr, Ala, Pro) are separated on a reversed-phase column (μBondapak C18) with 0.1 m phosphate buffer (pH 6.0) containing 6.75% methanol and 1.8% tetrahydrofuran, and are detected at the level of 10 fmol with excitation at 470 nm and emission at 530 nm.  相似文献   

11.
About 80 different muropeptides, the subunits which comprise the polymer murein of Escherichia coli, were resolved by high-performance liquid chromatography. The muropeptides were released from isolated murein by complete digestion with muramidase from Chalaropsis spec. The separation method is based on reversed phase chromatography of the sodium borohydride-reduced compounds using ODS (C18) columns and a linear gradient elution with sodium phosphate buffer and methanol as organic modifier. The effect of temperature, pH, ionic strength, and the steepness of the gradient and of different support materials on the separation of the muropeptides was investigated. The new method represents a major improvement over previous methods with respect to resolution, sensitivity, and speed. Analytical as well as preparative separations can be realized. Quantitative analysis of murein composition is achieved by a linear gradient from 50 mM sodium phosphate, pH 4.31, to 75 mM sodium phosphate, pH 4.95, containing 15% methanol for 135 min on a 250 X 4.6 mm 3-micron Hypersil ODS column at 55 degrees C using a flow rate of 0.5 ml/min. With uv detection at 205 nm about 20 micrograms of murein per analysis is sufficient. The detection limit per compound is about 5 ng. A method for the evaluation of the analytical data allowing a convenient comparison of different muropeptide pattern is described.  相似文献   

12.
Amygdalin and its metabolites in rat urine were identified using liquid chromatography-electrospray ionization (ESI) tandem ion-trap mass spectrometry. The purified rat urine sample was separated using a reversed-phase C18 column with 10 mM sodium phosphate buffer (pH 3.1) containing 30% methanol as the mobile phase, amygdalin and its metabolites were detected by on-line mass detector in selected ion monitoring (SIM) mode. The identification of the metabolites and elucidation of their structure were performed by comparing the changes in molecular masses (DeltaM), retention times and MS(2) spectral patterns of metabolites with those of parent drug. At least seven metabolites and the parent drug were found in rat urine after i.v. injection of 100 mg/kg doses of amygdalin. Among them, six metabolites were reported for the first time.  相似文献   

13.
Two procedures using liquid chromatography with electrochemical detection are described for the determination of dopamine (DA) and its two acidic metabolites, homovanillic acid (HVA) and 3,4-dihydroxyphenylacetic acid (DOPAC), in subregions of rat striatum and nucleus accumbens. A strong cation-exchange column was used for DA analysis and a C1 reversed-phase column was used for the analysis of the metabolites. Effects of pH, temperature and percentage of methanol on the retention time of HVA and DOPAC were studied. Levels of these compounds in the subregions of rat striatum and nucleus accumbens are reported.  相似文献   

14.
Two novel methods for the analysis of ellagic acid in pomegranate (Punica granatum) rinds are proposed. Capillary electrophoresis (CE) was performed in a bare fused-silica capillary using a buffer solution of tri(hydroxymethyl)aminomethane:potassium dihydrogen phosphate (pH 8.4) with an applied voltage of 20 kV and UV detection at 254 nm. HPLC analysis was performed with a Zobax SB C(18) column and a mobile phase consisting of methanol:ethyl acetate:potassium dihydrogen phosphate: phosphoric acid at a flow rate of 1.0 mL/min. Under optimised conditions, the HPLC retention and the CE migration times for ellagic acid were 10.32 and 12.23 min, respectively. Calibration curves of peak area vs. concentration gave correlation coefficients of 0.9999 for HPLC and 0.9990 for CE. The detection limits for HPLC and CE were 2.8 and 2.2 microg/mL, respectively. Average recoveries were 98.32 +/- 1.2% for HPLC and 96.52 +/- 2.8% for CE. Both methods were shown to be suitable for the determination of ellagic acid in pomegranate rinds extraction; however, the CE method required less solvent and gave better column efficiency, whilst the HPLC provided superior precision.  相似文献   

15.
M Enquist  J Hermansson 《Chirality》1989,1(3):209-215
A method for the determination of (R)- and (S)-atenolol in human plasma and urine is described. The enantiomers of atenolol are extracted into dichloromethane containing 3% heptafluorobutanol followed by acetylation with acetic anhydride at 60 degrees C for 2 h. The acetylated enantiomers were separated on a chiral alpha 1-AGP column. Quantitation was performed using fluorescence detection. A phosphate buffer pH 7.1 (0.01 M phosphate) containing 0.25% (v/v) acetonitrile was used as mobile phase. The described procedure allows the detection of less than 6 ng of each enantiomer in 1 ml plasma. The relative standard deviation is 4.4% at 30 ng/ml of each enantiomer in plasma. The plasma concentration of (R)- and (S)-atenolol did not differ significantly in two subjects who received a single tablet of racemic atenolol. The R/S ratio of atenolol in urine was approximately 1.  相似文献   

16.
Homovanillic acid (HVA) and 5-hydroxyindoleacetic acid (5-HIAA) in animal brains were simultaneously purified by two steps of column chromatography on Sephadex G-10 and QAE-Sephadex A-25. Perchloric acid extracts of brain tissue were directly passed through a column of Sephadex G-10. The gel retained both HVA and 5-HIAA, thereby separating them from Cl0?4 which interferes with subsequent purification process and from endogenous substances which give blank fluorescence. HVA was loosely adsorbed on the gel and was easily desorbed with dilute acetic acid. This effluent was successively passed onto a column of QAE-Sephadex A-25 placed beneath the G-10 column and the adsorbed HVA was eluted with 0.1 M Na2HPO4. The 5-HIAA remaining on the Sephadex G-10 without being desorbed by acetic acid was eluted with dilute ammonia. The recovery of both acid metabolites by this column procedure was more than 90%. Thus, it is possible to determine the levels of HVA and 5-HIAA in single brains of small rodents.  相似文献   

17.
W H Lyness 《Life sciences》1982,31(14):1435-1443
An assay has been developed for brain tryptophan using reverse-phase liquid chromatography with electrochemical detection. The method simultaneously assays dopamine (DA) and its metabolites, dihydroxyphenylacetic acid (DOPAC) and homovanillic acid (HVA), as well as 5-hydroxytryptamine (5-HT) and 5-hydroxyindoleacetic acid (5-HIAA). The method does not require elution from ion exchange resins. After deproteinization and centrifugation samples are injected directly onto the chromatographic column. It was found that small changes in mobile phase pH markedly influenced the retention time of tryptophan while elution of the indoleamines and catecholamines did not change. The assay of these endogenous compounds in a single injection proved not expedient but inexpensive. Values obtained using alumina and ion exchange resins yielded comparable values.  相似文献   

18.
A fast, simple, and a reliable high-performance liquid chromatography linked with electrochemical detector (HPLC-ECD) method for the assessment of lipoic acid (LA) and dihydrolipoic acid (DHLA) in plasma was developed using naproxen sodium as an internal standard (IS) and validated according to standard guidelines. Extraction of both analytes and IS from plasma (250 μl) was carried out with a single step liquid-liquid extraction applying dichloromethane. The separated organic layer was dried under stream of nitrogen at 40°C and the residue was reconstituted with the mobile phase. Complete separation of both compounds and IS at 30°C on Discovery HS C18 RP column (250 mm × 4.6 mm, 5 μm) was achieved in 9 min using acetonitrile: 0.05 M phosphate buffer (pH 2.4 adjusted with phosphoric acid) (52:48, v/v) as a mobile phase pumped at flow rate of 1.5 ml min(-1) using electrochemical detector in DC mode at the detector potential of 1.0 V. The limit of detection and limit of quantification for lipoic acid were 500 pg/ml and 3 ng/ml, and for dihydrolipoic acid were 3 ng/ml and 10 ng/ml, respectively. The absolute recoveries of lipoic acid and dihydrolipoic acid determined on three nominal concentrations were in the range of 93.40-97.06, and 93.00-97.10, respectively. Similarly coefficient of variations (% CV) for both intra-day and inter-day were between 0.829 and 3.097% for lipoic acid and between 1.620 and 5.681% for dihydrolipoic acid, respectively. This validated method was applied for the analysis of lipoic acid/dihydrolipoic acid in the plasma of human volunteers and will be used for the quantification of these compounds in patients with oxidative stress induced pathologies.  相似文献   

19.
Improved automated solid-phase microsequencing of peptides using DABITC   总被引:3,自引:0,他引:3  
The methylated purines O6-methyl- and 7-methylguanine were isolated from mouse liver DNA hydrolysates by means of a column cleanup employing a Sep Pak C-18 reverse-phase cartridge. The purine bases were eluted from the cartridge with methanol, evaporated to dryness, and then dissolved in mobile phase for liquid chromatographic analysis by normalphase chromatography. The system consisted of a LiChrosorb Si 60 column with a watersaturated mobile phase of 20% methanol in chloroform containing 0.001% H3PO4. The two methylated bases eluted before adenine or guanine. For extremely low-level (<300 pmol) quantitation, the peaks corresponding to O6-methyl- and 7-methylguanine were collected and then analyzed by reverse-phase chromotography with a LiChrosorb RP-18 column and a mobile phase of 5% methanol in pH 7 phosphate buffer (for 7-methylguanine) or 9.5% methanol/buffer (for O6-methylguanine). Comparisons were made with fluorescence detection and with scintillation counting (in animal studies where [14C]dimethylnitrosamine was used). Minimum detectable levels at 254 nm were about 3 ng (3:1 signal to noise ratio) for each of the title compounds. As low as 10 pmol/mg of each could be detected in DNA hydrolysates. Recoveries of O6-methyl- and 7-methylguanine from DNA spiked at 750 pmol/mg were greater than 80%.  相似文献   

20.
Serum retinol (bound to plasma retinol-binding protein, RBP) can be determined by direct injection of as little as 20 microliter of serum or plasma by using size-exclusion high-pressure liquid chromatography (SE-HPLC) with fluorescence detection. Toyo Soda TSK G-3000SW columns (0.75 X 7.5-cm guard column plus 0.75 X 30-cm analytical column) were eluted with 0.2 M NaCl/0.01 M phosphate buffer (pH 6.8) at 1 ml/min, with detection at 280 nm for protein elution. Fluorescence of the retinol-RBP complex was monitored with excitation at 334 nm (interference filter) and emission at 425 nm (long-pass filter). The retinol-RBP complex eluted as two peaks, the holo-RBP-transthyretin complex (apparent molecular weight 70,000) and holo-RBP (apparent molecular weight 9000). Identities of these peaks were established by immunodiffusion assay of the proteins and by extraction and analysis of retinol. Nonideal interactions with the column packing seem to be responsible for the low apparent molecular weight of holo-RBP. The first peak predominated when large volumes of serum (100 to 250 microliters) were injected, and the second when small volumes (5 to 50 microliters) were analyzed. The integrated area of the two fluorescence peaks due to retinol bound to RBP was proportional to the volume of a serum sample injected over the range 5 to 250 microliters.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号