首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Tissue softening is commonly reported during mechanical testing of biological tissues in vitro. The loss of stiffness may be due to viscoelasticity-induced softening (the time-history of load-caused softening) and strain-induced stress softening (the maximum previous load-caused softening). However, the knowledge about tissue softening behaviour is presently poor. The aims of this study were to distinguish whether the loss of the stiffness during preconditioning was due to strain softening or viscoelasticity and to test the tissue softening in circumferential and longitudinal direction in the guinea pig oesophagus. Eight repeated pressure controlled ramp distensions and eight uniaxial tensile-release ramp stretches in three series were done on eight guinea pig oesophagi. The stress–strain curves were used to display the time-dependency (viscoelasticity) and the maximum previous load-caused softening (strain softening) in circumferential and longitudinal directions. For both the longitudinal and the circumferential softening, the peak stress and stiffness produced during the first loading were bigger than those produced in the remaining loadings. The stress loss due to strain softening was about three times more than that due to viscoelasticity in the longitudinal direction. The strain increased more than two times between the strain softening and viscoelastic softening in the circumferential direction. With a stress level of 20 kPa, the stiffness in the circumferential direction lost more than that in the longitudinal direction (P<0.05), indicating the anisotropic softening properties in the oesophagus. In conclusion, the stiffness loss during preconditioning is mainly attributed to strain softening, appears irreversible and is anisotropic.  相似文献   

2.
Visual impairment and intracranial pressure (VIIP) syndrome is characterized by a number of permanent ophthalmic changes, including loss of visual function. It occurs in some astronauts during long-duration spaceflight missions. Thus, understanding the pathophysiology of VIIP is currently a major priority in space medicine research. It is hypothesized that maladaptive remodeling of the optic nerve sheath (ONS), in response to microgravity-induced elevations in intracranial pressure (ICP), contributes to VIIP. However, little is known about ONS biomechanics. In this study, we developed a custom mechanical testing system that allowed for unconfined lengthening, twisting, and circumferential distension of the porcine ONS during inflation and axial loading. Data were fit to a four-fiber family constitutive equation to extract material and structural parameters. Inflation testing showed a characteristic “cross-over point” in the pressure–diameter curves under different axial loads in all samples that were tested; the cross-over pressure was \(10.3 \pm 0.95\) mmHg (\(\hbox {mean} \pm \hbox {SEM}\)). Large sample-to-sample variations were observed in the circumferential strain, while only modest variations were observed in the circumferential stress. Multiphoton microscopy revealed that the collagen fibers of the ONS were primarily oriented axially when the tissue was loaded. The existence of this cross-over behavior is expected to be neuroprotective, as it would avoid optic nerve compression during routine changes in gaze angle, so long as ICP was within the normal range. Including these observations into computational models of VIIP will help provide insight into the pathophysiology of VIIP and could help identify risk factors and potential interventions.  相似文献   

3.
The stress and strain in the vessel wall are important determinants of vascular physiology and pathophysiology. Vessels are constrained radially by the surrounding tissue. The hypothesis in this work is that the surrounding tissue takes up a considerable portion of the intravascular pressure and significantly reduces the wall strain and stress. Ten swine of either sex were used to test this hypothesis. An impedance catheter was inserted into the carotid or femoral artery, and after mechanical preconditioning pressure-cross-sectional area relations were obtained with the surrounding tissue intact and dissected away (untethered), respectively. The radial constraint of the surrounding tissue was quantified as an effective perivascular pressure on the outer surface of the vessel, which was estimated as 50% or more of the intravascular pressure. For carotid arteries at pressure of 100 mmHg, the circumferential wall stretch ratio in the intact state was approximately 20% lower than in the untethered state and the average circumferential stress was reduced by approximately 70%. For femoral arteries, the reductions were approximately 15% and 70%, respectively. These experimental data support the proposed hypothesis and suggest that in vitro and in vivo measurements of the mechanical properties of vessels must be interpreted with consideration of the constraint of the surrounding tissue.  相似文献   

4.
Uniaxial and biaxial mechanical properties of purified elastic tissue from the proximal thoracic aorta were studied to understand physiological load distributions within the arterial wall. Stress–strain behaviour was non-linear in uniaxial and inflation tests. Elastic tissue was 40% stiffer in the circumferential direction compared to axial in uniaxial tests and~100% stiffer in vessels at an axial stretch ratio of 1.2 or 1.3 and inflated to physiological pressure. Poisson’s ratio vθz averaged 0.2 and vzθ increased with circumferential stretch from ~0.2 to ~0.4. Axial stretch had little impact on circumferential behaviour. In intact (unpurified) vessels at constant length, axial forces decreased with pressure at low axial stretches but remained constant at higher stretches. Such a constant axial force is characteristic of incrementally isotropic arteries at their in vivo dimensions. In purified elastic tissue, force decreased with pressure at all axial strains, showing no trend towards isotropy. Analysis of the force–length–pressure data indicated a vessel with vθz≈0.2 would stretch axially 2–4% with the cardiac pulse yet maintain constant axial force. We compared the ability of 4 mathematical models to predict the pressure-circumferential stretch behaviour of tethered, purified elastic tissue. Models that assumed isotropy could not predict the stretch at zero pressure. The neo-Hookean model overestimated the non-linearity of the response and two non-linear models underestimated it. A model incorporating contributions from orthogonal fibres captured the non-linearity but not the zero-pressure response. Models incorporating anisotropy and non-linearity should better predict the mechanical behaviour of elastic tissue of the proximal thoracic aorta.  相似文献   

5.
The transforming growth factor-β (TGF-β) signaling pathway is often misregulated during cancer progression. In early stages of tumorigenesis, TGF-β acts as a tumor suppressor by inhibiting proliferation and inducing apoptosis. However, as the disease progresses, TGF-β switches to promote tumorigenic cell functions, such as epithelial-mesenchymal transition (EMT) and increased cell motility. Dramatic changes in the cellular microenvironment are also correlated with tumor progression, including an increase in tissue stiffness. However, it is unknown whether these changes in tissue stiffness can regulate the effects of TGF-β. To this end, we examined normal murine mammary gland cells and Madin-Darby canine kidney epithelial cells cultured on polyacrylamide gels with varying rigidity and treated with TGF-β1. Varying matrix rigidity switched the functional response to TGF-β1. Decreasing rigidity increased TGF-β1-induced apoptosis, whereas increasing rigidity resulted in EMT. Matrix rigidity did not change Smad signaling, but instead regulated the PI3K/Akt signaling pathway. Direct genetic and pharmacologic manipulations further demonstrated a role for PI3K/Akt signaling in the apoptotic and EMT responses. These findings demonstrate that matrix rigidity regulates a previously undescribed switch in TGF-β-induced cell functions and provide insight into how changes in tissue mechanics during disease might contribute to the cellular response to TGF-β.  相似文献   

6.
Unexplained length-dependence of flexural rigidity and Young's modulus of microtubules is studied using an orthotropic elastic shell model. It is showed that vibration frequencies and buckling load predicted by the accurate orthotropic shell model are much lower than that given by the approximate isotropic beam model for shorter microtubules, although the two models give almost identical results for sufficiently long microtubules. It is this inaccuracy of the isotropic beam model used by all previous researchers that leads to reported lower flexural rigidity and Young's modulus for shorter microtubules. In particular, much lower shear modulus and circumferential Young's modulus, which only weaken flexural rigidity of shorter microtubules, are responsible for the observed length-dependence of the flexural rigidity. These results confirm that longitudinal Young's modulus of microtubules is length-independent, and the observed length-dependence of the flexural rigidity and Young's modulus is a result of strongly anisotropic elastic properties of microtubules which have a length-dependent weakening effect on flexural rigidity of shorter microtubules.  相似文献   

7.
Active systolic moduli for the circumferential (E theta) and longitudinal (E phi) axes of the left ventricle were determined along with circumferential and longitudinal contractile filament stress (sigma theta and sigma phi) and circumferential and longitudinal fiber strain (epsilon theta and epsilon phi). These material property parameters were determined at four points during cardiac systole. Thirty-nine patients comprising five clinical groups were evaluated using pressure and volume data acquired from single-plane cineangiography. The results indicate that the active moduli exponentially decrease during cardiac systole. Characteristic variations from normal differentiated the various pathological groups. With compensated volume overload, E theta was significantly reduced during the latter half of systole (p less than 0.25). With decompensated volume overload, both E theta and E phi were not significantly different from the normal group throughout cardiac systole. With compensated pressure overload, both E theta and E phi were significantly lower than the normal group at end-systole (p less than 0.005; p less than 0.005). With congestive cardiomyopathy, both E theta and E phi were significantly greater during the latter half of systole compared to the normal group (p less than 0.05 and p less than or equal to 0.025).  相似文献   

8.
The anatomy of young and old stems of Aristolochia macrophylla has been investigated for a better understanding of how secondary growth processes cause changes in the stem anatomy of a lianescent plant. In A. macrophylla, following an increase in volume of secondary vascular tissues, the cortical tissues are deformed and the outer sclerenchymatous cylinder ruptures. Morphometric measurements prove that the inner zone of the cortical parenchymatous tissue is compressed prior to the rupture of the outer sclerenchymatous cylinder. After the rupture has occurred, the radial width of the inner primary cortex slightly increases again. This could be caused by strain relaxation, suggesting that the inner primary cortex mechanically behaves similarly to cellular technical foam rubbers. Two different experiments were undertaken to test the outer cortical cylinders mechanically. The outer cortical cylinders comprise the outer sclerenchymatous cortical tissue and a collenchymatous sheath underneath the epidermis and the epidermis. In a first experiment, transverse compression loads were applied to the outside of the cortical cylinders causing ovalization of the cylinder until failure. This experiment allowed the Young's Modulus of the outer cortical cylinders to be determined. In a second set of experiments, radial hydraulic pressure was applied to the inside of the cortical cylinders, mimicking the mechanical effects of internal growth processes. The increase of the internal pressure finally led to rupture of the cortical cylinders. The circumferential stresses acting on the inner surface of the cortical cylinders were calculated. These data allow quantitative estimates of the radial and circumferential pressures effected by vascular secondary growth processes during ontogeny in A. macrophylla stems. The experimental results further indicate that the outer sclerenchymatous cylinder is the main contributor to mechanical stability of young A. macrophylla stems.  相似文献   

9.
The biomechanical response of normal and pathologic human abdominal aortic tissue to uniaxial loading conditions is insufficient for the characterization of its three-dimensional (3D) mechanical behavior. Planar biaxial mechanical evaluation allows for 3D constitutive modeling of nearly incompressible tissues, as well as the investigation of the nature of mechanical anisotropy. In the current study, 26 abdominal aortic aneurysm (AAA) tissue samples and 8 age-matched (> 60 years of age) nonaneurysmal abdominal aortic (AA) tissue samples were obtained and tested using a tension-controlled biaxial testing protocol. Graphical response functions (Sun et al., 2003. J. Biomech. Eng. 125, 372-380) were used as a guide to describe the pseudo-elastic response of AA and AAA. Based on the observed pseudo-elastic response, a four-parameter exponential strain energy function developed by Vito (1990. J. Biomech. Eng. 112, 153-159) was used from which both an individual specimen and group material parameter sets were determined for both AA and AAA. Peak Green strain values in the circumferential (Ethetatheta,max) and longitudinal (ELL,max) directions under an equibiaxial tension of 120 N/m were also compared. The strain energy function fit all of the individual specimens well with an average R2 of 0.95 +/- 0.02 and 0.90 +/- 0.02 (mean +/- SEM) for the AA and AAA groups, respectively. The average Ethetatheta,max at 200 N/m equibiaxial tension was found to be significantly smaller for AAAs as compared to AAs (0.07 +/- 0.01 versus 0.13 +/- 0.03, respectively; p < 0.01). There was also a pronounced increase in the circumferential stiffness for AAA tissue as compared to AA tissue, indicating a larger degree of anisotropy for this tissue as compared to age-matched AA tissue. We also observed that the four-parameter Fung-elastic model was not able to fit the AAA tissue mechanical response using physically realistic material parameter values. It was concluded that aneurysmal degeneration of the abdominal aorta is associated with an increase in mechanical anisotropy, with preferential stiffening in the circumferential direction.  相似文献   

10.
Recent studies have renewed interest in the effects of perivascular tethering on vascular mechanics, particularly growth and remodeling. We quantified effects of axial and circumferential tethering on rabbit pial arterioles from the ventral occipital lobe of the brain. The homeostatic axial pre-stretch, which is influenced by perivascular tethering, was measured in situ to be 1.24±0.04. Using a cannulated microvessel preparation, wall mechanics were then quantified in vitro for isolated arterioles at low (1.10) or normal (1.24) values of axial stretch and for tethered arterioles having perivascular support. Axial stretch did not significantly affect changes in circumferential stretch or stress upon pressurization, but circumferential tethering caused arteriolar geometry to change from a circular cross-section at normal pressure to an elliptical one at pressures above and below normal. Calculations suggested that the observed levels of ellipticity could cause a modest decrease in volumetric blood flow, but also a pronounced variation in shear stress around the circumference of the arteriole. An elliptical cross-section could thus increase vascular resistance or promote luminal remodeling at pressures different from normal. This characterization of effects of perivascular tethering on pial arterioles should prove useful in future studies of roles of perturbed cerebral blood flow on the propensity of the cerebral microcirculation to remodel.  相似文献   

11.
The annulus fibrosus of the intervertebral disk experiences multidirectional tension in vivo, yet the majority of mechanical property testing has been uniaxial. Therefore, our understanding of how this complex multilayered tissue responds to loading may be deficient. This study aimed to determine the mechanical properties of porcine annular samples under uniaxial and biaxial tensile loading. Two-layer annulus samples were isolated from porcine disks from four locations: anterior superficial, anterior deep, posterior superficial, and posterior deep. These tissues were then subjected to three deformation conditions each to a maximal stretch ratio of 1.23: uniaxial, constrained uniaxial, and biaxial. Uniaxial deformation was applied in the circumferential direction, while biaxial deformation was applied simultaneously in the circumferential and compressive directions. Constrained uniaxial consisted of a stretch ratio of 1.23 in the circumferential direction while holding the tissue stationary in the axial direction. The maximal stress and stress-stretch ratio (S-S) moduli determined from the biaxial tests were significantly higher than those observed during both the uniaxial tests (maximal stress, 97.1% higher during biaxial; p=0.002; S-S moduli, 117.9% higher during biaxial; p=0.0004) and the constrained uniaxial tests (maximal stress, 46.8% higher during biaxial; S-S moduli, 82.9% higher during biaxial). These findings suggest that the annulus is subjected to higher stresses in vivo when under multidirectional tension.  相似文献   

12.
Isolated tracheal segments were studied in vitro to determine how inflation affects the length and tension of the contracted and relaxed trachealis muscle. Circumferential trachealis muscle lengths were measured from cross-sectional radiographs taken during stepwise inflation of intact 20-cm-long tracheal segments to an inflation pressure of 25 cmH2O. A tracheal length spanning two cartilage rings was then cut out and mounted in a tissue bath using clips attached at the points of muscle insertion into the cartilage. The ring was stretched open along the axis of the muscle, and the resulting forces of the relaxed and contracted muscle and the cartilage were measured. Muscle lengths and tensions during inflation of the trachea were determined by comparing pressure vs. length and force vs. length measurements. During inflation from 0 to 25 cmH2O, the circumferential length of the trachealis muscle contracted with 10(-5) M acetylcholine increased from 48 to 70% of its length of maximal active tension (Lmax), while the relaxed muscle increased from 80 to 93% Lmax. The length of the contracted muscle was maintained at a nearly constant proportion of its relaxed length at each pressure.  相似文献   

13.
Adventitial mechanics were studied on the basis of adventitial tube tests and associated stress analyses utilizing a thin-walled model. Inflation tests of 11 nonstenotic human femoral arteries (79.3 +/- 8.2 yr, means +/- SD) were performed during autopsy. Adventitial tubes were separated anatomically and underwent cyclic, quasistatic extension-inflation tests using physiological pressures and high pressures up to 100 kPa. Associated circumferential and axial stretches were typically <20%, indicating "adventitiosclerosis." Adventitias behaved nearly elastically for both loading domains, demonstrating high tensile strengths (>1 MPa). The anisotropic and strongly nonlinear mechanical responses were represented appropriately by two-dimensional Fung-type stored-energy functions. At physiological pressure (13.3 kPa), adventitias carry ~25% of the pressure load in situ, whereas their circumferential and axial stresses were similar to the total wall stresses (~50 kPa in both directions), supporting a "uniform stress hypothesis." At higher pressures, they became the mechanically predominant layer, carrying >50% of the pressure load. These significant load-carrying capabilities depended strongly on circumferential and axial in-vessel prestretches (mean values: 0.95 and 1.08). On the basis of these results, the mechanical role of the adventitia at physiological and hypertensive states and during balloon angioplasty was characterized.  相似文献   

14.
Hydraulic permeability is an important material property of cartilaginous tissues, governing the rate of fluid flow, which is crucial to tissue biomechanics and cellular nutrition. The effects of strain, anisotropy, and region on the hydraulic permeability in meniscus tissue have not been fully elucidated. Using a one-dimensional direct permeation test, we measured the hydraulic permeability within statically compressed porcine meniscus specimens, prepared such that the explants were in either the axial or circumferential direction of either the central or horn (axial direction only) region of the medial and lateral menisci. A constant flow was applied and the pressure difference was measured using pressure transducers. Specimens were tested under 10–20% compressive strain. Permeability values were in the range of 1.53–1.87 × 10−15 m4/Ns, which is comparable to values found in the literature. Permeability was significantly anisotropic, being higher in the circumferential direction than in the axial direction. Additionally, there was a significant negative correlation between strain level and permeability for all groups. Lastly, no statistically significant difference was found between permeability coefficients from different regional locations. This study provides important information regarding structure-function relationships in meniscal tissues that helps to elucidate biomechanics and transport in the tissue, and can aid in the understanding of the tissue’s role in the function of the knee joint and onset of osteoarthritis.  相似文献   

15.
Increased right atrial (RA) and ventricular (RV) chamber volumes are a late maladaptive response to chronic pulmonary hypertension. The purpose of the current investigation was to characterize the early compensatory changes that occur in the right heart during chronic RV pressure overload before the development of chamber dilation. Magnetic resonance imaging with radiofrequency tissue tagging was performed on dogs at baseline and after 10 wk of pulmonary artery banding to yield either mild RV pressure overload (36% rise in RV pressure; n = 5) or severe overload (250% rise in RV pressure; n = 4). The RV free wall was divided into three segments within a midventricular plane, and circumferential myocardial strain was calculated for each segment, the septum, and the left ventricle. Chamber volumes were calculated from stacked MRI images, and RA mechanics were characterized by calculating the RA reservoir, conduit, and pump contribution to RV filling. With mild RV overload, there were no changes in RV strain or RA function. With severe RV overload, RV circumferential strain diminished by 62% anterior (P = 0.04), 42% inferior (P = 0.03), and 50% in the septum (P = 0.02), with no change in the left ventricle (P = 0.12). RV filling became more dependent on RA conduit function, which increased from 30 ± 9 to 43 ± 13% (P = 0.01), than on RA reservoir function, which decreased from 47 ± 6 to 33 ± 4% (P = 0.04), with no change in RA pump function (P = 0.94). RA and RV volumes and RV ejection fraction were unchanged from baseline during either mild (P > 0.10) or severe RV pressure overload (P > 0.53). In response to severe RV pressure overload, RV myocardial strain is segmentally diminished and RV filling becomes more dependent on RA conduit rather than reservoir function. These compensatory mechanisms of the right heart occur early in chronic RV pressure overload before chamber dilation develops.  相似文献   

16.
In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements are subjects of current interest and investigation. The objectives of the current study were to (1) determine whether a transversely isotropic, linearly elastic, homogeneous material model of the meniscal tissue is necessary to achieve a normal contact pressure distribution on the tibial plateau, (2) determine which material and boundary condition (attachments) parameters affect the contact pressure distribution most strongly, and (3) set tolerances on these parameters to restore the contact pressure distribution to within a specified error. To satisfy these objectives, a finite element model of the tibio-femoral joint of a human cadaveric knee (including both menisci) was used to study the contact pressure distribution on the tibial plateau. To validate the model, the contact pressure distribution on the tibial plateau was measured experimentally in the same knee used to create the model. Within physiologically reasonable bounds on five material parameters and four attachment parameters associated with a meniscal replacement, an optimization was performed under 1200 N of compressive load on the set of nine parameters to minimize the difference between the experimental and model results. The error between the experimental and model contact variables was minimized to 5.4%. The contact pressure distribution of the tibial plateau was sensitive to the circumferential modulus, axial/radial modulus, and horn stiffness, but relatively insensitive to the remaining six parameters. Consequently, both the circumferential and axial/radial moduli are important determinants of the contact pressure distribution, and hence should be matched in the design and/or selection of meniscal replacements. In addition, during surgical implantation of a meniscal replacement, the horns should be attached with high stiffness bone plugs, and the attachments of the transverse ligament and deep medial collateral ligament should be restored to minimize changes in the contact pressure distribution, and thereby possibly prevent the degradation of articular cartilage.  相似文献   

17.
Analysis of the passive mechanical properties of rat carotid arteries   总被引:5,自引:1,他引:4  
The passive mechanical properties of rat carotid arteries were studied in vitro. Using a tensile testing machine and a piston pump, intact segments of carotid arteries were subjected to large deformations both in the longitudinal and circumferential directions. Internal pressure, external diameter, length and longitudinal force were measured during the experiment and compared with the in vivo dimensions of the segments prior to excision. The anisotropic mechanical properties of the vessel wall material were analyzed using incremental elastic moduli and incremental Poisson's ratios. The results suggest that there is a characteristic deformation pattern common to all vessels investigated which is highly correlated with the conditions of loading that occur in vivo. That is, under average physiological deformation of the vessel, the longitudinal force is nearly independent of internal pressure. In this range of loading the circumferential incremental elastic modulus is nearly independent of longitudinal strain. However, the longitudinal and radial incremental elastic moduli vary significantly with deformation in this direction. The values of the moduli in all three directions increase with raising internal pressure. The weak coupling between circumferential and longitudinal direction in the wall material of carotid arteries is shown by the small value of the corresponding incremental Poisson's ratios.  相似文献   

18.
Background: Physiotherapy of edema in cases with obstructed main lymphatics of lower limbs requires knowledge of how high external pressures should be applied manually or set in compression devices in order to generate tissue pressures high enough to move tissue fluid to nonswollen regions and to measure its flow rate. Methods: We measured tissue fluid pressure and flow in subcutaneous tissue of lymphedematous limbs stages II to IV at rest and during pneumatic compression under various pressures and inflation timing. An 8-chamber sequential compression device inflated to pressures 50-120?mmHg, for 50 sec each chamber, with no distal deflation, was used. Pressures were measured using a wick-in-needle and electronic manometer. Fluid flow was calculated from continuously recorded changes in limb circumference using strain gauge plethysmography. Results: Before massage, in all stages of lymphedema, stagnant tissue fluid pressures in subcutaneous tissue ranged between -1 and +10 mmHg and did not differ from those measured in normal subjects. Pressures generated in tissue fluid by pneumatic compression reached 40-100 mmHg and were lower than those in inflated chambers. High pressure gradient through the skin was caused by its rigidity (fibrosis) and dissipation of applied compression force to proximal noncompressed limb regions. The calculated volumes of displaced tissue fluid ranged from 10 to 30 ml per compression cycle, to reach in some cases 100 ml in the groin region. Conclusions: Tissue fluid pressures generated by a pneumatic device were found lower than in the compression chambers. The obtained results point to the necessity of applying high pressures and longer compression times to generate effective tissue fluid pressures and to provide enough time for moving the stagnant fluid.  相似文献   

19.
Approximately half of all cardiovascular deaths associated with acute coronary syndrome occur when the thin fibrous cap tissue overlying the necrotic core in a coronary vessel is torn, ripped or fissured under the action of high blood pressure. From a biomechanics point of view, the rupture of an atheroma is due to increased mechanical stresses in the lesion, in which the ultimate stress (i.e. peak circumferential stress (PCS) at failure) of the tissue is exceeded. Several factors including the cap thickness, morphology, residual stresses and tissue composition of the atheroma have been shown to affect the PCS. Also important, we recently demonstrated that microcalcifications (μCalcs>5 µm are a common feature in human atheroma caps, which behave as local stress concentrators, increasing the local tissue stress by at least a factor of two surpassing the ultimate stress threshold for cap tissue rupture. In the present study, we used both idealized µCalcs with spherical shape and actual µCalcs from human coronary atherosclerotic caps, to determine their effect on increasing the circumferential stress in the fibroatheroma cap using different hyperelastic constitutive models. We have found that the stress concentration factor (SCF) produced by μCalcs in the fibroatheroma cap is affected by the material tissue properties, μCalcs spacing, aspect ratio and their alignment relative to the tensile axis of the cap.  相似文献   

20.
Uniaxial tensile and relaxation tests were carried out on annulus fibrosus samples carved out in the circumferential direction. Images were shot perpendicularly to the loading direction. Digital image correlation techniques accurately measured the evolution of full displacement fields in both transverse directions: plane of fibres and plane of lamellae. In the fibre plane, strains were governed by the reorientation of fibres along the loading direction. This implies strong transverse shrinkage with quasi-linear behaviour. Conversely, a wide range of behaviour was observed in the lamella plane: from shrinkage to swelling. Strong nonlinear evolutions were generally obtained. The strain field in the lamella plane generally presented a central strip section with more pronounced swelling. Our physical interpretation relies on the porous nature of annulus tissue and its anisotropic stiffness. Indeed, the liquid over-pressure generated inside the sample by the strong shrinkage in the fibre plane discharges in the perpendicular direction since rigidity is lower in the lamella plane. Regarding the strain field measured in the lamella plane, this interpretation agrees with (a) symmetric strain distribution with respect to the longitudinal axis of samples, (b) the reversal in behaviour from shrinkage to swelling and (c) the decrease in strain during relaxation tests associated with outward flows. The variety of transverse behaviours observed experimentally could result from uncertainties regarding the initial reference state of tissue samples. Since the mechanical behaviour is highly nonlinear, experimental results underline that a slight uncertainty concerning the pre-stress applied to samples can lead to wide variability in the mechanical properties identified.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号