共查询到20条相似文献,搜索用时 28 毫秒
1.
Objective
To determine whether the baseline retinal sensitivity can predict the best-corrected visual acuity (BCVA) at 1 month after intravitreal bevacizumab (IVB) in eyes with macular edema (ME) associated with a branch retinal vein occlusion (BRVO).Subjects and Methods
We evaluated 16 eyes of 16 patients who had ME associated with a BRVO. The mean ± standard deviation age was 69.1 ± 8.9 years, and all had a single IVB injection. The BCVA, central macular thickness (CMT), integrity of the ellipsoid zone (EZ) of the photoreceptors, and retinal sensitivity were determined before (baseline) and at 1 day, 1 week, and 1 month following the IVB. The average threshold retinal sensitivity (AT) within the central 10° was determined by Macular Integrity Assessment. The correlations between the BCVA at 1 month and the CMT, integrity of the EZ, and AT at each visit were determined.Results
One month after IVB, the BCVA improved significantly from 0.56 ± 0.27 logMAR units to 0.32 ± 0.28 logMAR units, and the CMT from 611.4 ± 209.3 μm to 258.7 ± 64.0 μm (P <0.05). The AT improved significantly from 17.9 ± 5.3 dB to 21.2 ± 5.0 dB (P <0.05). At 1 day after the treatment, both the integrity of the EZ (r = 0.59) and the retinal sensitivity (r = 0.76) were moderately correlated with the BCVA at 1 month.Conclusion
These results indicate that both the integrity of the EZ and the AT at 1 day after the IVB can predict the BCVA after treatment for ME associated with BRVO. There is a possibility that these parameters will predict the effectiveness of IVB for each case. 相似文献2.
Michele Carbonelli Chiara La Morgia Giacomo Savini Maria Lucia Cascavilla Enrico Borrelli Filipe Chicani Carolina do V. F. Ramos Solange R. Salomao Vincenzo Parisi Jerry Sebag Francesco Bandello Alfredo A. Sadun Valerio Carelli Piero Barboni 《PloS one》2015,10(6)
Purpose
To investigate the thickness of the retinal layers and to assess the prevalence of macular microcysts (MM) in the inner nuclear layer (INL) of patients with mitochondrial optic neuropathies (MON).Methods
All patients with molecularly confirmed MON, i.e. Leber’s Hereditary Optic Neuropathy (LHON) and Dominant Optic Atrophy (DOA), referred between 2010 and 2012 were enrolled. Eight patients with MM were compared with two control groups: MON patients without MM matched by age, peripapillary retinal nerve fiber layer (RNFL) thickness, and visual acuity, as well as age-matched controls. Retinal segmentation was performed using specific Optical coherence tomography (OCT) software (Carl Zeiss Meditec). Macular segmentation thickness values of the three groups were compared by one-way analysis of variance with Bonferroni post hoc corrections.Results
MM were identified in 5/90 (5.6%) patients with LHON and 3/58 (5.2%) with DOA. The INL was thicker in patients with MON compared to controls regardless of the presence of MM [133.1±7μm vs 122.3±9μm in MM patients (p<0.01) and 128.5±8μm vs. 122.3±9μm in no-MM patients (p<0.05)], however the outer nuclear layer (ONL) was thicker in patients with MM (101.4±1mμ) compared to patients without MM [77.5±8mμ (p<0.001)] and controls [78.4±7mμ (p<0.001)]. ONL thickness did not significantly differ between patients without MM and controls.Conclusion
The prevalence of MM in MON is low (5-6%), but associated with ONL thickening. We speculate that in MON patients with MM, vitreo-retinal traction contributes to the thickening of ONL as well as to the production of cystic spaces. 相似文献3.
Mathieu Uro Olivier Beauchet Mehdi Cherif Alix Graffe Dan Milea Cedric Annweiler 《PloS one》2015,10(6)
Background
Vitamin D deficiency is associated with smaller volume of optic chiasm in older adults, indicating a possible loss of the visual axons and their cellular bodies. Our objective was to determine whether vitamin D deficiency in older adults is associated with reduced thickness of the ganglion cell complex(GCC) and of the retinal nerve fibre layer(RNFL), as measured with high-definition optical coherence tomography(HD-OCT).Methods
Eighty-five French older community-dwellers without open-angle glaucoma and patent age-related macular degeneration(mean, 71.1±4.7years; 45.9%female) from the GAIT study were separated into 2 groups according to serum 25OHD level(i.e., deficient≤25nmol/L or sufficient>25nmol/L). Measurements of GCC and RNFL thickness were performed using HD-OCT. Age, gender, body mass index, number of comorbidities, dementia, functional autonomy, intracranial volume, visual acuity, serum calcium concentration and season of testing were considered as potential confounders.Results
Mean serum 25OHD concentration was 58.4±26.8nmol/L. Mean logMAR visual acuity was 0.03±0.06. Mean visual field mean deviation was -1.25±2.29dB. Patients with vitamin D deficiency(n=11) had a reduced mean GCC thickness compared to those without vitamin D deficiency(72.1±7.4μm versus 77.5±7.5μm, P=0.028). There was no difference of the mean RNFL thickness in these two groups(P=0.133). After adjustment for potential confounders, vitamin D deficiency was associated with reduced GCC thickness(ß=-5.12, P=0.048) but not RNFL thickness(ß=-9.98, P=0.061). Specifically, vitamin D deficiency correlated with the superior medial GCC area(P=0.017) and superior temporal GCC area(P=0.010).Conclusions
Vitamin D deficiency in older patients is associated with reduced mean GCC thickness, which can represent an early stage of optic nerve damage, prior to RNFL loss. 相似文献4.
Purpose
To investigate repeatability and reproducibility of thickness of eight individual retinal layers at axial and lateral foveal locations, as well as foveal width, measured from Spectralis spectral domain optical coherence tomography (SD-OCT) scans using newly available retinal layer segmentation software.Methods
High-resolution SD-OCT scans were acquired for 40 eyes of 40 young healthy volunteers. Two scans were obtained in a single visit for each participant. Using new Spectralis segmentation software, two investigators independently obtained thickness of each of eight individual retinal layers at 0°, 2° and 5° eccentricities nasal and temporal to foveal centre, as well as foveal width measurements. Bland-Altman Coefficient of Repeatability (CoR) was calculated for inter-investigator and inter-scan agreement of all retinal measurements. Spearman''s ρ indicated correlation of manually located central retinal thickness (RT0) with automated minimum foveal thickness (MFT) measurements. In addition, we investigated nasal-temporal symmetry of individual retinal layer thickness within the foveal pit.Results
Inter-scan CoR values ranged from 3.1μm for axial retinal nerve fibre layer thickness to 15.0μm for the ganglion cell layer at 5° eccentricity. Mean foveal width was 2550μm ± 322μm with a CoR of 13μm for inter-investigator and 40μm for inter-scan agreement. Correlation of RT0 and MFT was very good (ρ = 0.97, P < 0.0005). There were no significant differences in thickness of any individual retinal layers at 2° nasal compared to temporal to fovea (P > 0.05); however this symmetry could not be found at 5° eccentricity.Conclusions
We demonstrate excellent repeatability and reproducibility of each of eight individual retinal layer thickness measurements within the fovea as well as foveal width using Spectralis SD-OCT segmentation software in a young, healthy cohort. Thickness of all individual retinal layers were symmetrical at 2°, but not at 5° eccentricity away from the fovea. 相似文献5.
Purpose
To compare the abilities of spectral-domain optical coherence tomography (OCT) (SD-OCT; Spectralis, Heidelberg Engineering) and swept-source OCT (SS-OCT; DRI-OCT1 Atlantis system, Topcon) for analyzing the macular inner retinal layers in diagnosing glaucoma.Methods
The study included 60 patients with primary open-angle glaucoma (POAG) and 60 healthy control subjects. Macular cube area was scanned using SD-OCT and SS-OCT on the same day to assess the thicknesses of the macular retinal nerve fiber layer (mRNFL), ganglion cell layer plus inner plexiform layer (GCIPL), and total retinal layer in nine subfields defined by the Early Treatment Diabetic Retinopathy Study (ETDRS). The abilities of the parameters to discriminate between the POAG and control groups were assessed using areas under the receiver operating characteristic curves (AUCs).Results
Glaucoma-associated mRNFL and GCIPL thinning was more common in the outer zones than inner zones for both SD-OCT and SS-OCT. The mRNFL and GCIPL measurements showed distinct pattern differences between SD-OCT and SS-OCT in each ETDRS subfield. Although the glaucoma-diagnosis ability was comparable between SD-OCT and SS-OCT for most of the parameters, AUC was significantly larger for SD-OCT measurements of the GCIPL thickness in the outer temporal zones (p = 0.003) and of the mRNFL thickness in the outer nasal zones (p = 0.001), with the former having the largest AUC for discriminating POAG from healthy eyes (AUC = 0.894).Conclusion
Spectralis SD-OCT and DRI SS-OCT have similar glaucoma-diagnosis abilities based on macular inner layer thickness analysis. However, Spectralis SD-OCT was potentially superior to DRI SS-OCT in detecting GCIPL thinning in the outer temporal zone, where the glaucomatous damage predominantly occurs. 相似文献6.
Yong Woo Kim Jin Wook Jeoung Dai Woo Kim Michael J. A. Girard Jean Martial Mari Ki Ho Park Dong Myung Kim 《PloS one》2016,11(3)
Purpose
Quantitative evaluation of lamina cribrosa (LC) posterior bowing in primary open-angle glaucoma (POAG) eyes using swept-source optical coherence tomography.Methods
Patients with POAG (n = 123 eyes) and healthy individuals of a similar age (n = 92 eyes) were prospectively recruited. Anterior laminar insertion depth (ALID) was defined as the vertical distance between the anterior laminar insertion and a reference plane connecting the Bruch’s membrane openings (BMO). The mean LC depth (mLCD) was approximated by dividing the area enclosed by the anterior LC, the BMO reference plane, and the two vertical lines for ALID measurement by the length between those two vertical lines. The LC curvature index was defined as the difference between the mLCD and the ALID. The factors influencing the LC curvature index were evaluated.Results
The ALID and mLCD were significantly larger in POAG eyes than in healthy controls (P < 0.05). The LC curvature index was significantly larger in POAG eyes than in healthy controls on both the horizontal (85.8 ± 34.1 vs. 68.2 ± 32.3 μm) and vertical meridians (49.8 ± 38.5 vs. 32.2 ± 31.1 μm, all P < 0.001). Multivariate regression showed significant associations of greater disc area (P < 0.001), vertical C/D ratio (P < 0.001) and mLCD (P < 0.001), smaller rim area (P = 0.001), thinner average RNFLT (P < 0.001), and myopic refraction (P = 0.049) with increased LC curvature index. There was no difference in the LC curvature index between mild (MD > –6 dB) and moderate-to-advanced glaucoma (MD < –6 dB, P = 0.95).Conclusions
LC posterior bowing was increased in POAG eyes, and was significantly associated with structural optic nerve head (ONH) changes but not with functional glaucoma severity. Quantitative evaluation of LC curvature can facilitate assessment of glaucomatous ONH change. 相似文献7.
Enting Gao Binyao Chen Jianling Yang Fei Shi Weifang Zhu Dehui Xiang Haoyu Chen Mingzhi Zhang Xinjian Chen 《PloS one》2015,10(6)
Purpose
To assess the correlation and agreement between the Topcon built-in algorithm and our graph-based algorithm in measuring the total and regional macular thickness for normal and glaucoma subjects.Methods
A total of 228 normal eyes and 93 glaucomatous eyes were enrolled in our study. All patients underwent comprehensive ophthalmic examination and Topcon 3D-OCT 2000 scan. One eye was randomly selected for each subject. The thickness of each layer and the total and regional macular thickness on an Early Treatment of Diabetic Retinopathy Study (ETDRS) chart were measured using the Topcon algorithm and our three-dimensional graph-based algorithm. Correlation and agreement analyses between these two algorithms were performed.Results
Our graph search algorithm exhibited a strong correlation with Topcon algorithm. The macular GCC thickness values for normal and glaucoma subjects ranged from 0.86 to 0.91 and from 0.78 to 0.90, and the regional macular thickness values ranged from 0.79 to 0.96 and 0.70 to 0.95, respectively. Small differences were observed between the Topcon algorithm and our graph-based algorithm. The span of 95% limits of agreement of macular GCC thickness was less than 28 μm in both normal and glaucoma subjects, respectively. These limits of total and regional macular thickness were 15.5 μm and 23.1 μm for normal subjects and 29.1 μm and 46.4 μm for glaucoma subjects, respectively.Conclusion
Our graph-based algorithm exhibited a high degree of agreement with the Topcon algorithm with respect to thickness measurements in normal and glaucoma subjects. Moreover, our graph-based algorithm can segment the retina into more layers than the Topcon algorithm does. 相似文献8.
Purpose
To describe the ethnic differences in central corneal thickness (CCT) in population-based samples of ethnic Bai, Yi and Han people living in rural China.Methods
6504 adults (2119 ethnic Bai, 2202 ethnic Yi and 2183 ethnic Han) aged 50 years or older participated in the study. Each subject underwent standardized ocular examinations and interviewer-administered questionnaires for risk factor assessment. CCT was measured for both eyes using an ultrasound pachymeter. Regression and principal component analysis were performed to examine the relationship of ethnicity and other factors with CCT.Results
The mean CCT readings were 536.4 ± 34.2 μm in ethnic Bai, 532.1 ± 32.1 μm in ethnic Yi and 529.6 ± 32.7 μm in ethnic Han adults (P<0.001), respectively. There was a decreasing trend of mean CCT with increasing age across all ethnic groups. In multivariate linear regression models, increasing CCT was associated with younger age (P<0.001), male gender (P<0.001), Bai (P<0.001) or Yi (P<0.001) ethnicity, greater body mass index (P<0.001), higher systolic blood pressure (P<0.001), greater corneal curvature (P<0.001), deeper anterior chamber (P < 0.001), and thicker lens (P<0.001). Ethnicity contributed significantly to presence of thin cornea (60%; P< 0.001) compared with other factors. CCT had similar impact on intraocular pressure readings across all ethnic groups.Conclusions
This study of more than 6500 multiethnic participants demonstrates significant ethnic variations in CCT, with Han ethnicity having the thinnest cornea compared with ethnic minorities. These data are essential to guide future multiethnic clinical trials on CCT-related ocular conditions such as glaucoma. 相似文献9.
Kazuko Omodaka Takaaki Horii Seri Takahashi Tsutomu Kikawa Akiko Matsumoto Yukihiro Shiga Kazuichi Maruyama Tetsuya Yuasa Masahiro Akiba Toru Nakazawa 《PloS one》2015,10(4)
Purpose
Although the lamina cribrosa (LC) is the primary site of axonal damage in glaucoma, adequate methods to image and measure it are currently lacking. Here, we describe a noninvasive, in vivo method of evaluating the LC, based on swept-source optical coherence tomography (SS-OCT), and determine this method’s ability to quantify LC thickness.Methods
This study comprised 54 eyes, including normal (n = 18), preperimetric glaucoma (PPG; n = 18), and normal tension glaucoma (NTG; n = 18) eyes. We used SS-OCT to obtain 3 x 3 mm cube scans of an area centered on the optic disc, and then synchronized reconstructed B- and en-face images from this data. We identified the LC in these B-scan images by marking the visible borders of the LC pores. We marked points on the anterior and posterior borders of the LC in 12 B-scan images in order to create a skeleton model of the LC. Finally, we used B-spline interpolation to form a 3D model of the LC, including only reliably measured scan areas. We calculated the average LC thickness (avgLCT) in this model and used Spearman''s rank correlation coefficient to compare it with circumpapillary retinal nerve fiber layer thickness (cpRNFLT).Results
We found that the correlation coefficient of avgLCT and cpRNFLT was 0.64 (p < 0.01). The coefficient of variation for avgLCT was 5.1%. AvgLCT differed significantly in the groups (normal: 282.6 ± 20.6 μm, PPG: 261.4 ± 15.8 μm, NTG: 232.6 ± 33.3 μm). The normal, PPG and NTG groups did not significantly differ in age, sex, refractive error or intraocular pressure (IOP), although the normal and NTG groups differed significantly in cpRNFLT and Humphrey field analyzer measurements of mean deviation.Conclusion
Thus, our results indicate that the parameters of our newly developed method of measuring LC thickness with SS-OCT may provide useful and important data for glaucoma diagnosis and research. 相似文献10.
Purpose
To study the relationship between amplitude of spontaneous retinal venous pulsatility (SRVP) and retinal nerve fibre layer (RNFL) thickness in glaucomatous eyes, and to determine if this parameter may be a potential marker for glaucoma severity.Method
85 subjects including 50 glaucoma (21 males, 67±10 yrs) and 35 normals (16 males, 62±11 yrs) were studied. SRVP amplitude was measured using the Dynamic Vessel Analyser (DVA, Imedos, Germany) at four regions of the retina simultaneously within one disc diameter from the optic disc—temporal-superior (TS), nasal-superior (NS), temporal-inferior (TI) and nasal-inferior (NI)). This was followed by RNFL thickness measurement using spectral domain optical coherence tomography (Spectralis OCT). The correlation between SRVP amplitude and corresponding sectoral RNFL thickness was assessed by means of non-linear regression (i.e. logarithmic). Linear regression was also applied and slopes were compared using analysis of covariance (ANCOVA).Results
Greater SRVP amplitude was associated with thicker RNFL. Global SRVP amplitude was significantly lower in glaucoma eyes compared with normals (p<0.0001). The correlation coefficient of the linear regression between RNFL and SRVP at TS, NS, TI and NI quadrants in the glaucoma group were r = 0.5, 0.5, 0.48, 0.62. Mean SRVP amplitude and RNFL thickness for TS, NS, TI and NI quadrants were 4.3±1.5, 3.5±1.3, 4.7±1.6, 3.1±1 μm and 96±30, 75±22, 89±35 and 88±30 μm, respectively. The ANCOVA test showed that the slope of linear regression between the four quadrants was not significant (p>0.05). Since the slopes are not significantly different, it is possible to calculate one slope for all the data. The pooled slope equals 10.8 (i.e. RNFL = 10.8SRVP+41).Conclusion
While SRVP was present and measurable in all individuals, the amplitude of SRVP is reduced in glaucoma with increasing RNFL loss. Our findings suggest the degree of SRVP may be an additional marker for glaucoma severity. Further studies are needed to determine the mechanism of reduction in SRVP, and whether changes can predict increased risk of progression. 相似文献11.
Ningning Gao Qixi Zhai Yinyan Li Kun Huang Donglin Bian Xuemei Wang Caigang Liu Hong Xu Teng Zhang 《PloS one》2015,10(11)
Objective
To explore the relationship between TβRII [type II TGFβ (transforming growth factor β) receptor] expression and clinicopathological characteristics, and to evaluate the prognostic significance of TβRII expression in breast cancer.Methods
Clinicopathological data and prognostic information of 108 patients with histologically confirmed breast cancer who were surgically treated at China Medical University between January 2007 and September 2008 were reviewed and the association between the clinicopathological characteristics and TβRII expression was analyzed by chi-square test and multivariate analysis. The expression of TβRII was assessed by immunohistochemistry.Results
Of the 108 patients, 60 cases were TβRII positive and 48 cases were negative. There was no significant association between TβRII expression of the patients older than 40 years and that of the younger than 40 years (56.0% vs 50.0%; P = 0.742). The TβRII expression rate was significantly increased in patients with lymph node metastasis compared to those without lymph node metastasis (67.40% vs 46.8%; P = 0.033). Statistically significant relationships were found between increasing tumor clinical stage and high TβRII expression (P = 0.011). TβRII expression was not associated with the expression of ER(estrogen receptor)、PR, (progesterone receptor)、Her-2 (human epidermal growth factor receptor 2) (P = 0.925,P = 0.861, and P = 0.840, respectively). Patients with high TβRII expression showed poorer 5-year disease-free survival (DFS) compared to those with low expression (66.7% vs 45.6%; P = 0.028) by univariate analysis. Survival analysis demonstrated that TβRII was associated with poor DFS (P = 0.011). Subgroup analysis revealed that TβRII expression was associated with shorter DFS in patients with lymph node metastasis, ER-positive, PR-positive or Her-2-negative tumors (P = 0.006, P = 0.016, P = 0.022, and P = 0.033, respectively). Cox regression analysis revealed that high TβRII expression was related to poor 5-year DFS, and it was an independent factor for predicting the poor outcome for breast cancer patients (P = 0.016).Conclusions
High levels of TβRII expression were associated with lymph node metastasis, increasing tumor clinical stage, and poorer 5-year DFS in patients with breast cancer. TβRII may be a potential prognostic marker for breast cancer. 相似文献12.
Qiao Hu Xiao-Yan Wang Li-Ke Kang Hai-Ming Wei Chun-Mei Xu Tao Wang Zong-Hua Wen 《PloS one》2016,11(2)
Objective
To prepare arginine-glycine-aspartate (RGD)-targeted ultrasound contrast microbubbles (MBs) and explore the feasibility of their use in assessing dynamic changes in αvβ3 integrin expression in a murine model of tumor angiogenesis.Methods
RGD peptides were conjugated to the surfaces of microbubbles via biotin-avidin linkage. Microbubbles bearing RADfK peptides were prepared as controls. The RGD-MBs were characterized using an Accusizer 780 and optical microscopy. The binding specificity of the RGD-MBs for ανβ3-expressing endothelial cells (bEnd.3) was demonstrated in vitro by a competitive inhibition experiment. In an in vivo study, mice bearing tumors of three different stages were intravenously injected with RGD-MBs and subjected to targeted, contrast-enhanced, high-frequency ultrasound. Subsequently, tumors were harvested and sectioned for immunofluorescence analysis of ανβ3 expression.Results
The mean size of the RGD-MBs was 2.36 ± 1.7 μm. The RGD-MBs showed significantly higher adhesion levels to bEnd.3 cells compared to control MBs (P < 0.01). There was rarely binding of RGD-MBs to αvβ3-negative MCF-7 cells. Adhesion of the RGD-MBs to the bEnd.3 cells was significantly inhibited following treatment with anti-alpha(v) antibodies. The quantitative acoustic video intensity for high-frequency, contrast-enhanced ultrasound imaging of subcutaneous human laryngeal carcinoma (Hep-2) tumor xenografts was significantly higher in small tumors (19.89 ± 2.49) than in medium tumors (11.25 ± 2.23) and large tumors (3.38 ± 0.67) (P < 0.01).Conclusions
RGD-MBs enable noninvasive in vivo visualization of changes in tumor angiogenesis during tumor growth in subcutaneous cancer xenografts. 相似文献13.
Jeffrey R. Peterson Lauren S. Blieden Alice Z. Chuang Laura A. Baker Mohammed Rigi Robert M. Feldman Nicholas P. Bell 《PloS one》2016,11(1)
Purpose
Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT).Methods
Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18–35, 36–45, 46–55, 56–65, and 66–79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter.Results
Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age.Conclusion
This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states. 相似文献14.
Purpose
To assess whether macular Bruch´s membrane gets lengthened in axial myopia.Methods
Using the enhanced depth imaging mode of spectral-domain optical coherence tomography and examining a subgroup of participants of the population-based cross-sectional Beijing Eye Study, we measured the length of Bruch´s membrane (“MacBMLength”) from the fovea to the temporal edge of parapapillary gamma zone, and the distance between the fovea and the temporal optic disc border. Parapapillary gamma zone was defined as the parapapillary region without Bruch´s membrane. We additionally measured ocular biometric parameters and assessed non-ophthalmologic variables.Results
Measurements of MacBMLength were performed on 322 individuals. MacBMLength (mean: 3.99±0.33 mm; range: 3.17–4.93 mm) was not significantly associated with any systemic parameter or ocular biometric parameter. Gamma zone width (mean: 0.18±0.30mm; range: 0.00–2.61mm) was associated (multivariate analysis; correlation coefficient r:0.80) with longer axial length (P<0.001; standardized correlation coefficient beta: 0.60; non-standardized correlation coefficient B:0.11; 95%CI: 0.09,0.14) and with longer fovea-optic disc border distance (P<0.001; beta:0.28; B:0.19; 95%CI:0.14,0.25), but not with MacBMLength (P = 0.42). Fovea-temporal disc border distance (mean: 4.16±0.44mm; range: 3.17–5.86mm) was associated (overall correlation coefficient: 0.68) with longer axial length (P<0.001; beta: 0.36; B: 0.10; 95%CI: 0.06, 0.13), after adjusting for flatter anterior chamber depth (P = 0.003; beta:-0.14; B:-0.14; 95%CI: -0.23,-0.05) and wider parapapillary gamma zone (P<0.001; beta:0.42; B:0.62; 95%CI:0.44,0.81).Conclusions
In contrast to parapapillary gamma zone width and fovea-disc border distance, MacBMLength was not significantly associated with axial length. Axial elongation associated increase in fovea-disc distance may predominantly occur through development or elongation of parapapillary gamma zone, while macular Bruch´s membrane may mostly be independent of axial elongation. 相似文献15.
Zhe Xu Meixiao Shen Liang Hu Xiran Zhuang Mei Peng Di Hu Jing Liu Jianhua Wang Jia Qu Fan Lu 《PloS one》2015,10(5)
Purpose
To determine the impact of flap creation methods for sub-Bowman’s keratomileusis (SBK) on central Bowman’s layer thickness.Methods
SBK flaps were made by Moria microkeratome for 20 subjects and by femtosecond (FEMTO) laser for 21 subjects. Corneal sublayer thicknesses were measured by ultra-high resolution optical coherence tomography before SBK and at 1 day, 1 week, 2 weeks, and 1 month afterwards. Each subject was imaged twice on each visit. Thicknesses of central epithelium, Bowman’s layer, flap, and total cornea were calculated using a custom-made automated image processing algorithm. The repeatability of sublayer thickness measurements was tested by the intraclass correlation coefficient (ICC) and by the coefficient of repeatability (CoR) at 1 week post-SBK.Results
ICCs of the Moria and FEMTO groups were ≥0.959 and ≥0.961 respectively for all sublayer measurements. The segmentation CoRs were less than 6.78% and 5.63% respectively. For both groups, microdistortions were present in the epithelium and Bowman’s layer after SKB. The flap thickness of the Moria group was 9.8 μm (95% confidence interval: 4.8 – 14.8μm) thinner than the FEMTO group one day after SBK (independent samples t-test, P < 0.05). Bowman’s layer became thicker by 1.6 ± 1.1 μm and 1.7 ± 1.6 μm one day post-SBK for the Moria and FEMTO groups (repeated ANOVA, P < 0.05) and then remained stable. Corneal and sublayer thickness were similar between the two groups.Conclusions
Central Bowman’s layer thickness increased 1 day post-SBK. Flap creation by Moria microkeratome and femtosecond laser did not have significantly different impacts on Bowman’s layer thickness following SBK.Trial Registration
Chinese Clinical Trial Registry (ChiCTR) NO: ChiCTR-OCH-14004525 相似文献16.
Purpose
To investigate the association between blood lead levels and prevalence of age-related macular degeneration (AMD).Methods
A nationwide population-based cross-sectional study included 4,933 subjects aged over 40 years who participated in the 2008–2012 Korean National Health and Nutrition Examination Survey, and for whom fundus photographs were available. All participants underwent a standardized interview, evaluation of blood lead concentration, and a comprehensive ophthalmic examination. Digital fundus photographs (45°) were taken of both eyes under physiological mydriasis. All fundus photographs were graded using an international classification and grading system.Results
Mean blood lead levels were 3.15 μg/dL in men and 2.27 μg/dL in women (P < 0.001). After adjusting for potential confounders including age, gender, smoking status, total cholesterol levels, triglyceride levels, heart problems and strokes, the adjusted odds ratio (OR) in women for any AMD was 1.86 (95% Confidence Interval [CI], 1.03–3.36) and for early AMD was 1.92 (95% CI, 1.06–3.48), for those in the highest quintile of lead level compared with the lowest quintile. In men, however, blood lead level was not significantly associated with AMD.Conclusions
Blood lead levels were higher in men, but were only associated with AMD in women. Increased levels of blood lead may be involved in the pathogenesis of AMD development in women. 相似文献17.
Aris Konstantopoulos Xiao Wei Tan Gwendoline Tze Wei Goh Padmanabhan Saraswathi Liyan Chen Chan Lwin Nyein Lei Zhou Roger Beuerman Donald Tiang Hwee Tan Jod Mehta 《PloS one》2015,10(10)
Background
Artificial cornea transplantation, keratoprosthesis, improves vision for patients at high risk of failure with human cadaveric cornea. However, post-operative infection can cause visual loss and implant extrusion in 3.2–17% of eyes. Long-term vancomycin drops are recommended following keratoprosthesis to prevent bacterial keratitis. Evidence, though, in support of this practice is poor. We investigated whether prophylactic vancomycin drops prevented bacterial keratitis in an animal keratoprosthesis model.Methodology
Twenty-three rabbits were assigned either to a prophylactic group (n = 13) that received vancomycin 1.4% drops 5 times/day from keratoprosthesis implantation to sacrifice, or a non-prophylactic group (n = 10) that received no drops. All rabbits had Staphylococcus aureus inoculation into the cornea at 7–12 days post-implantation and were sacrificed at predetermined time-points. Prophylactic and non-prophylactic groups were compared with slit-lamp photography (SLP), anterior segment optical coherence tomography (AS-OCT), and histology, immunohistochemistry and bacterial quantification of excised corneas. Corneal vancomycin pharmacokinetics were studied in 8 additional rabbits.Results
On day 1 post-inoculation, the median SLP score and mean±SEM AS-OCT corneal thickness (CT) were greater in the non-prophylactic than the prophylactic group (11 vs. 1, p = 0.049 and 486.9±61.2 vs. 327.4±37.1 μm, p = 0.029 respectively). On days 2 and 4, SLP scores and CT were not significantly different. Immunohistochemistry showed a greater CD11b+ve/non-CD11b+ve cell ratio in the non-prophylactic group (1.45 vs. 0.71) on day 2. Bacterial counts were not significantly different between the two groups. Corneal vancomycin concentration (2.835±0.383 μg/ml) exceeded minimum inhibitory concentration (MIC) for Staphylococcus aureus only after 16 days of vancomycin drops. Two of 3 rabbits still developed infection despite bacterial inoculation after 16 days of prophylactic drops.Conclusions
Prophylactic vancomycin drops provided short-term benefit, but did not prevent infection. Achieving MIC in the cornea was not sufficient to prevent Staphylococcus aureus keratitis. Patients should continue to be counselled regarding the risk of infection following keratoprosthesis. 相似文献18.
Duncan J. Campbell Jithendra B. Somaratne David L. Prior Michael Yii James F. Kenny Andrew E. Newcomb Darren J. Kelly Mary Jane Black 《PloS one》2013,8(11)
Background
Obesity is associated with diastolic dysfunction, lower maximal myocardial blood flow, impaired myocardial metabolism and increased risk of heart failure. We examined the association between obesity, left ventricular filling pressure and myocardial structure.Methods
We performed histological analysis of non-ischemic myocardium from 57 patients (46 men and 11 women) undergoing coronary artery bypass graft surgery who did not have previous cardiac surgery, myocardial infarction, heart failure, atrial fibrillation or loop diuretic therapy.Results
Non-obese (body mass index, BMI, ≤30 kg/m2, n=33) and obese patients (BMI >30 kg/m2, n=24) did not differ with respect to myocardial total, interstitial or perivascular fibrosis, arteriolar dimensions, or cardiomyocyte width. Obese patients had lower capillary length density (1145±239, mean±SD, vs. 1371±333 mm/mm3, P=0.007) and higher diffusion radius (16.9±1.5 vs. 15.6±2.0 μm, P=0.012), in comparison with non-obese patients. However, the diffusion radius/cardiomyocyte width ratio of obese patients (0.73±0.11 μm/μm) was not significantly different from that of non-obese patients (0.71±0.11 μm/μm), suggesting that differences in cardiomyocyte width explained in part the differences in capillary length density and diffusion radius between non-obese and obese patients. Increased BMI was associated with increased pulmonary capillary wedge pressure (PCWP, P<0.0001), and lower capillary length density was associated with both increased BMI (P=0.043) and increased PCWP (P=0.016).Conclusions
Obesity and its accompanying increase in left ventricular filling pressure were associated with lower coronary microvascular density, which may contribute to the lower maximal myocardial blood flow, impaired myocardial metabolism, diastolic dysfunction and higher risk of heart failure in obese individuals. 相似文献19.
Francesco De Cobelli Giulio Pezzetti Sergio Margari Antonio Esposito Francesco Giganti Giulia Agostini Alessandro Del Maschio 《PloS one》2015,10(4)
Introduction
Abdominal pain in PNH has never been investigated by in-vivo imaging studies. With MRI, we aimed to assess mesenteric vessels flow and small bowel wall perfusion to investigate the ischemic origin of abdominal pain.Materials and Methods
Six PNH patients with (AP) and six without (NOP) abdominal pain underwent MRI. In a blinded fashion, mean flow (MF, quantity of blood moving through a vessel within a second, in mL·s-1) and stroke volume (SV, volume of blood pumped out at each heart contraction, in mL) of Superior Mesenteric Vein (SMV) and Artery (SMA), areas under the curve at 60 (AUC60) and 90 seconds (AUC90) and Ktrans were assessed by two operators.Results
Mean total perfusion and flow parameters were lower in AP than in NOP group. AUC60: 84.81 ± 11.75 vs. 131.73 ± 18.89 (P < 0.001); AUC90: 102.33 ± 14.16 vs. 152.58 ± 22.70 (P < 0.001); Ktrans: 0.0346 min-1 ± 0.0019 vs. 0.0521 ± 0.0015 (P = 0.093 duodenum, 0.009 jejunum/ileum). SMV: MF 4.67 ml/s ± 0.85 vs. 8.32 ± 2.14 (P = 0.002); SV 3.85 ml ± 0.76 vs. 6.55 ± 1.57 (P = 0.02). SMA: MF 6.95 ± 2.61 vs. 11.2 ± 2.32 (P = 0.07); SV 6.52 ± 2.19 vs. 8.78 ± 1.63 (P = 0.07). We found a significant correlation between MF and SV of SMV and AUC60 (MF:ρ = 0.88, P < 0.001; SV: ρ = 0.644, P = 0.024), AUC90 (MF: ρ = 0.874, P < 0.001; SV:ρ = 0.774, P = 0.003) and Ktrans (MF:ρ = 0.734, P = 0.007; SV:ρ = 0.581, P = 0.047).Conclusions
Perfusion and flow MRI findings suggest that the impairment of small bowel blood supply is significantly associated with abdominal pain in PNH. 相似文献20.
Julie Boisramé-Helms Grégory Meyer Su Emmanuelle Degirmenci Mélanie Burban Valérie Schini-Kerth Luc Cynober Jean-Pascal De Bandt Michel Hasselmann Ferhat Meziani 《PloS one》2016,11(1)