首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, rapid, sensitive and reproducible method based on solid-phase extraction (SPE) and acidified silica clean-up was developed for the measurement of 12 polybrominated diphenyl ethers (PBDEs), including BDE 209, and 2,2',4,4',5,5'-hexabromobiphenyl (BB 153) in human serum. Several solid-phase sorbents (Empore C(18), Isolute Phenyl, Isolute ENV+ and OASIS HLB) were tested and it was found that OASIStrade mark HLB (500 mg) gives the highest absolute recoveries (between 64% and 95%, R.S.D.<17%, n=3) for all tested analytes and internal standards. Removal of co-extracted biogenic materials was performed using a 6 ml disposable cartridge containing (from bottom to top) silica impregnated with sulphuric acid, activated silica and anhydrous sodium sulphate. PBDEs and BB 153 were quantified using a gas chromatograph coupled with a mass spectrometer (MS) operated in electron-capture negative ionization mode. The method limits of quantification (LOQ) ranged between 0.2 and 25 pg/ml serum (0.1 and 4 ng/g lipid weight). LOQs were dependent on the analyte levels in procedural blanks which resulted in the highest LOQs for PBDE congeners found in higher concentrations in blanks (e.g. BDE 47, 99 and 209). The use of OASIS HLB SPE cartridge allowed a good method repeatability (within- and between-day precision<12% for all congeners, except for BDE 209<17%, n=3). The method was applied to serum samples from a random Belgian population. The obtained results were within the range of PBDE levels in other non-exposed population from Europe.  相似文献   

2.
In this study, a method for partly automated sample preparation and fully automated solid-phase extraction method for plasma, kidney and liver samples for various retinoids like all-trans-4-oxo-retinoic acid, 13-cis-4-oxo-retinoic acid, 13-cis-retinoic acid, 9-cis-retinoic acid, all-trans-retinoic acid, retinol and retinyl palmitate was established. Plasma, embryo-, kidney-and liver-homogenates were automatically mixed and extracted on multiple usage solid-phase (C2) extraction cartridges immediately before HPLC analysis. Automated cleaning, preconditioning and incorporation of the loaded cartridge to fully automated HPLC separation and quantification of the various retinoids in a single HPLC run was established. The recovery of the retinoids was generally between 80 and 90%. Intra-day repeatability was < 11.7%. As little as 1.2 ng/ml could be quantified in lipid-mixture standard samples. This method allows a highly automated sample preparation and a fully automated solid-phase extraction with good selectivity for the study of endogenous retinoids and retinoids after nutritional supplementations and pharmacological applications in several biological samples.  相似文献   

3.
The separation of organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), and polybrominated diphenyl ether (PBDE) congeners was evaluated on four capillary columns: 60 m x 0.25 mm i.d., 0.25 microm film thickness RTX-5MS and DB-XLB capillary columns, and 60 m x 0.18 mm i.d., 0.25 microm film thickness DB-XLB and DB-5MS capillary columns. Based on performance, capacity, and cost, the RTX-5MS (60 m x 0.25 mm i.d., 0.25 microm thickness) and the DB-XLB (60 m x 0.25 mm i.d., 0.25 microm film thickness) were selected for the analysis of human serum extracts by using gas chromatography/electron-capture detection. In contrast to previous studies, the oven temperature program affords the separation of congeners that are not separated by using other combinations of capillary columns, most notably PBDE-47 and PCB 180. In addition, the method enables determination of OCPs, PCBs, and PBDEs prevalent in a single extract of serum, which can lead to considerable time savings in the analysis of large number of samples collected for epidemiologic studies.  相似文献   

4.
An new method for the determination of polychlorinated biphenyls (PCBs) in serum samples of up to 1 ml has been developed. The procedure consisted in the solid-phase extraction (SPE) of the analytes on an Oasis cartridge and the subsequent on-line elimination of the fat by directly dropping of the eluate from the SPE cartridge on a multilayer column placed below the cartridge. This configuration allowed minimising of the sample manipulation as well as the time, solvent and sorbent consumption (i.e. complete sample preparation can be accomplished in about 1 h with only 3 ml of toluene and 300 mg of silica). The SPE plus clean-up method developed showed a satisfactory performance for the analysis of PCBs in rat serum samples providing similar recoveries (i.e. range 73-128% for most of the congeners selected) at the different spiking levels investigated (1.25, 0.50 and 0.25 ng/ml). Detection limits using a microelectron capture detector were in the range 0.01-0.30 ng/ml of serum and the relative standard deviations of the complete method better than 18% irrespective of the PCB concentration. The validated method has been applied to the evaluation for the first time of the PCB levels in serum samples of up to 1 ml from individuals of an Egyptian Vulture colony in Spain.  相似文献   

5.
The sponge Dysidea herbacea was collected from the Mandapam Coast, Tamilnadu, India. Isolated gram quantities of hydroxylated polybrominated diphenyl ether (HO-PBDE) and semi-synthesized a series of new PBDEs derivatives and tested them for antibacterial and cytotoxic activities.  相似文献   

6.
A method for the isolation of polychlorinated biphenyls (PCBs) from human blood using solid-phase extraction (SPE) has been developed. The procedure incorporates decomposition of lipids by concentrated sulphuric acid directly on the SPE column. Conditions for transferring PCBs onto the SPE column and washing the decomposed blood components from the SPE column were optimised. After clean-up the extracts were analysed using gas chromatography with electron capture detection. An average recovery of PCBs from spiked blood samples was about 78±8% and an average precision was about 109±7%. Quantitation has been done using four internal standards and calibration curves based on five concentration levels. Low procedural blanks made it possible to determine PCBs in blood quantitatively at a level down to 2–10 pg g−1. The integrated method for blood is fast, less laborious than methods using liquid–liquid extraction and has a low consumption of organic solvents.  相似文献   

7.
A sensitive and specific method using reversed-phase liquid chromatography coupled with electrospray ionization-mass spectrometry (LC-ESI-MS) has been developed for the quantitative determination of flunitrazepam (F) and its metabolites 7-aminoflunitrazepam (7-AF), N-desmethylflunitrazepam (N-DMF) and 3-hydroxyflunitrazepam (3-OHF) in biological fluids. After the addition of deuterium labelled standards of F,7-AF and N-DMF, the drugs were isolated from urine or plasma by automated solid-phase extraction, then chromatographed in an isocratic elution mode with a salt-free eluent. The quantification was performed using selected ion monitoring of protonated molecular ions (M+H(+)). Experiments were carried out to improve the extraction recovery (81-100%) and the sensitivity (limit of detection 0.025 ng/ml for F and 7-AF, 0.040 ng/ml for N-DMF and 0.200 ng/ml for 3-OHF). The method was applied to the determination of F and metabolites in drug addicts including withdrawal urine samples and in one date-rape plasma and urine sample.  相似文献   

8.
Polybrominated diphenyl ethers (PBDEs), as a specific group of brominated flame retardants (BFR), are used in a variety of consumer products including electronics and household furnishings. In recent years, a marked increase in the levels of PBDEs in human biological tissues and fluids, especially breast milk, has been reported in several countries. However, few data are available from countries in the Asia-pacific region, including Singapore. This study presents a validated method procedure and the first available data of the concentrations of PBDE congeners: PBDE-47 (2,2,4,4-Tetrabromodiphenyl ether), PBDE-99 (2,2',4,4',5-Pentabromodiphenyl ether), PBDE-100 (2,2',4,4',6-Pentabromodiphenyl ether), PBDE-153 (2,2',4,4',5,5'-Hexabromodiphenyl ether), PBDE-154 (2,2',4,4',5,6'-Hexabromodiphenyl ether) in maternal adipose tissue collected from inhabitants of Singapore. Microwave-assisted extraction (MAE) of PBDEs spiked adipose tissues coupled with GC-MS analysis achieved comparable recoveries to a conventional Soxhlet Extraction (SE) procedure of between 70 and 130%. MAE also yielded comparable precision data (variance less than 13%) relative to the SE procedure. Spiked Carbon-13 PBDE congeners were also used as surrogates for MAE quality assurance and confirmed the efficiency of the procedure. PBDE congeners were detected in all of 16 maternal adipose tissues collected in Singapore, where levels were comparable to available data from Belgium.  相似文献   

9.
多溴二苯醚动物毒理学研究进展及其生态毒理学展望   总被引:4,自引:0,他引:4  
多溴二苯醚(PBDEs)作为阻燃剂,已被广泛应用于工业产品和家庭用品中.近年来,在土壤、沉积物、大气和生物体中普遍检测出PBDEs.PBDEs对哺乳动物、鸟类和鱼类都存在不同程度的毒害作用,其分布的广泛性、难降解性和对人体健康的不确定性已引起人们的普遍关注.基于国外动物毒理学研究成果,综合论述了PBDEs在生物体内的累积和排泄及其对动物肝酶活性、甲状腺、生殖和发育、神经系统和免疫系统等的影响及其潜在的人体健康危害,并分析了目前PBDEs毒理学研究中的问题,展望了未来PBDEs生态毒理学的研究方向.  相似文献   

10.
多溴二苯醚的环境暴露与生态毒理研究进展   总被引:22,自引:0,他引:22  
多溴二苯醚(PBDEs)是一类具有生态风险的新型环境有机污染物.作为阻燃剂,PBDEs已经被愈来愈广泛地添加到工业产品中,并因此对大气、水体、沉积物和土壤等环境介质及相关生态系统产生日益广泛的污染.鉴于这一环境新问题的产生,本文基于有限的资料,初步探讨了PBDEs的人为来源和环境暴露途径,大致给出了PBDEs在不同生物和人体不同组织器官中可能的存在及含量水平;在扼要介绍其基本性质的基础上,从甲状腺、神经系统和生殖发育毒性等三个方面分析了PBDEs对动物和人体可能产生的毒性效应与生态影响,以及PBDEs在生态系统中可能具有的生物积累和生物放大风险;并对今后研究PBDEs的环境暴露与生态效应以及人体健康影响等方面的工作重点进行了展望.  相似文献   

11.
An improved method for the determination of ethyl glucuronide (EtG) in human serum and urine was developed using solid-phase extraction (SPE) and gas chromatography (GC) with mass spectrometric detection (MS). EtG was isolated from serum and urine using aminopropyl SPE columns after deproteination with perchloric acid and hydrochloric acid, respectively. The chromatographic separation was performed on a DB 1701 fused-silica column. At a signal-to-noise ratio of 3:1, a quantification limit of 173 and 560 ng/ml and a detection limit of 37 and 168 ng/ml could be determined for serum and urine, respectively. This indicates high specificity and sensitivity of the described method. The mean absolute recovery was 85%, while intra- and inter-day precision of the assay were all less than 7.5%. The linearity of the calibration curves was satisfying as indicated by correlation coefficients of >0.993. The presented method provides the basis for determination and identification of EtG in human serum and urine samples in a low-concentration range for monitoring alcohol consumption during treatment for alcohol dependence and comorbid alcohol abuse of psychotherapy patients.  相似文献   

12.
A sensitive and automated method is described for determination of rifampicin in plasma samples for therapeutic drug monitoring by in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC). Important factors in the optimization of in-tube SPME are discussed, such as coating type, sample pH, sample draw/eject volume, number of draw/eject cycles, and draw/eject flow rate. Analyte pre-concentrated in the polyethylene glycol phase was directly transferred to the liquid chromatographic column by percolation of the mobile phase, without carryover. The method was linear over the 0.1-100 μg/mL range, with a linear coefficient value (r(2)) of 0.998. The inter-assay precision presented coefficient of variation ≤ 1.7%. The effectiveness and practicability of the proposed method are proven by analysis of plasma samples from ageing patients undergoing therapy with rifampicin.  相似文献   

13.
A review is presented of recent developments in the use of molecularly imprinted polymers (MIPs) as selective materials for solid-phase extraction. Compared with traditional sorbents, MIPs can not only concentrate but also selectively separate the target analytes from real samples, which is crucial for the quantitatively determination of analytes in complex samples. Consequently, as one of the most effective sorbents, MIPs have been successfully applied to the pretreatment of analytes in foods, drugs, and biological and environmental samples in the past five years.  相似文献   

14.
A review is presented of recent developments in the use of molecularly imprinted polymers (MIPs) as selective materials for solid-phase extraction. Compared with traditional sorbents, MIPs can not only concentrate but also selectively separate the target analytes from real samples, which is crucial for the quantitatively determination of analytes in complex samples. Consequently, as one of the most effective sorbents, MIPs have been successfully applied to the pretreatment of analytes in foods, drugs, and biological and environmental samples in the past five years.  相似文献   

15.
A fast automated extraction and clean-up procedure for low-level analysis of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and coplanar polychlorinated biphenyls (cPCBs) in biological fluids is presented. Online extraction of prepared fluids is carried out using disposable octadecyl bonded (C(18)) solid-phase extraction columns. Extracts are then cleaned up through disposable multi-layer silica (acidic, basic and neutral) and dispersed PX-21 carbon columns. This new methodology is compared with classical Soxhlet extraction and manual solid-phase extraction in terms of repeatability, reproducibility, accuracy and recovery rates for reference and certified materials. Robustness is evaluated on different matrices, such as cow's milk, breast milk and human serum. As a consequence of the reduced number of reusable glassware used, as well as lowering of solvent consumption, recorded blank levels are decreased in favor of limits of detection (LODs). Total analysis time and cost are further reduced using simultaneous sample preparation units and the sample throughput is increased compared to classical methods. As a result, this new approach appears to be suitable for the fast sample preparation often required for such fluids in case of emergency foodstuffs analysis or during large epidemiological studies.  相似文献   

16.
An improved method for the determination of selected organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in human serum was developed. The method requires low volume of serum (500 microl) and 48-96 samples per day can be prepared by one analyst without special automatic equipment. Initial extraction was performed using 96-well solid-phase extraction disk plates and was followed by a clean-up with silica gel/sulfuric acid. Different denaturation, elution and clean-up conditions were tested. Quantification was carried out by gas chromatography equipped with electron capture detector (GC-ECD) or mass spectrometer (GC-MS). Recoveries of PCB congeners 28, 52, 101, 118, 138, 153 and 180 and OCPs HCB, beta-HCH, p,p'-DDE and p,p'-DDT at two spiking levels (n=8) varied from 57 to 120%, and intra-day relative standard deviation from 1 to 11%, both depending on spiking level and compound. Inter-day relative standard deviation was <15% in all cases. Limit of quantification (LOQ) for these PCBs ranged from 0.08 to 0.13 ng/ml and for these OCPs from 0.16 to 0.40 ng/ml. The optimized method was applied to the analysis of 1000 serum samples from different places of Spain.  相似文献   

17.
A non-covalent molecularly imprinted polymer (MIP) was synthesised using naproxen (a non-steroidal, anti-inflammatory drug (NSAID)) as a template molecule. The MIP was chromatographically evaluated to confirm the imprinting effect, and was then applied as a selective sorbent in solid-phase extraction (SPE) to selectively extract naproxen. After this study, the MIP was used to extract naproxen from urine samples; it was demonstrated that by applying a selective washing step with acetonitrile (ACN) the compounds in the sample that were structurally related to naproxen could be eliminated.  相似文献   

18.
A bioanalytical method for the determination of piperaquine in 100 microL blood applied onto sampling paper, by solid-phase extraction and liquid chromatography, has been developed and validated. Blood spots were cut into small pieces prior to addition of 0.3M perchloric acid, acetonitrile and phosphate buffer containing an internal standard. The liquid phase was loaded onto a mixed phase cation-exchange (MPC) solid-phase extraction column. Piperaquine and the internal standard were analysed by liquid chromatography and separated on a Chromolith Performance (100 mm x 4.6 mm) column with acetonitrile:phosphate buffer pH 2.5, I = 0.1 (8:92, v/v) at the flow of 3.5 mL/min. The UV detection was performed at 345 nm. The intra-assay precision was 12.0% at 0.150 microM, 7.3% at 1.25 microM and 7.3% at 2.25 microM. The inter-assay precision was 1.8% at 0.150 microM, 5.2% at 1.25 microM and 2.8% at 2.25 microM. The lower limit of quantification (LLOQ) was determined to 0.050 microM where the precision was 14.7%.  相似文献   

19.
Hydroxylated polybrominated diphenyl ethers (OH-PBDEs) are a class of toxic environmental pollutants that are persistent, bioaccumulative, and difficult to degrade. Their structure is very similar to the thyroid hormone (T4) and uses the body’s thyroid transporter (TTR) binding to interfere with the endocrine balance, disrupting the body’s normal physiological activity. According to Fourier transform infrared spectroscopy and dynamics simulation of do_dssp module analysis, there are three kinds of OH-PBDEs that can induce TTR secondary structural changes. Fluorescence spectra and UV–Vis spectra show that for the three kinds of OH-PBDEs for TTR, the main methods of quenching are static quenching and non-radiative energy transfer. According to thermodynamic analysis, ΔG < 0, ΔH > 0, and ΔS > 0 combine to show that the hydrophobic interaction is the main driving force of the combination. From the molecular docking analysis, it was found that 4′-hydroxy-2,2′,4,5′- tetrabromodiphenyl ether (4′-OH-BDE49) and 4 hydroxy-2,2′,3,4′,5,6,6′- heptabromodiphenyl ether (4-OH-BDE188) had a cationic–π interaction with TTR, whereas 4 hydroxy-2,2′,3,4,5,5′,6- heptabromodiphenyl ether (4-OH-BDE187) was bonded to TTR by hydrogen bonds to form stable complexes. In this paper, we highlight the consistency of spectroscopic experiments and computer simulations so as to provide a reliable analytical method for the toxicological properties of small molecule contaminants.  相似文献   

20.
For the implementation and validation of an automated `high-throughput' solid-phase extraction (SPE) system, using microtiter solid-phase technology and a pipetting robot, a SPE method previously validated manually for cimetidine in human plasma was adapted. Sample cleanup was performed by means of SPE using Microlute extraction plates in the 96-well format, each well filled with 50 mg of Varian C18 sorbent. Separation was performed by reversed-phase high-performance liquid chromatography (HPLC) with UV detection at 234 nm. The validated calibration range was from 0.100 to 5.00 mg/l, with an inaccuracy and imprecision below 20% at all concentration levels. Validation results on linearity, specificity, precision, accuracy and stability are shown and are found to be adequate. Cross-check analysis of samples from a clinical trial showed that there is a good correlation between results obtained by the automated method and results obtained by the manual method. The average sample preparation time for a technician decreased from approximately 4 min per sample to 0.6 min. A sample throughput of at least 160 samples per day can be achieved, the HPLC analysis time being the rate-limiting step.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号