首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The 1,536-well microplate format has widely supplanted the 384-well microplate format for high-throughput screening and for IC(50) assays. Previously, liquid chromatography/mass spectrometry (LC/MS) analyses of such samples required manual transfers of the wells of interest from a 1,536-well plate into a 384-well plate. Because this manual transfer introduced a source of potential error, it became clear that a more appropriate solution would be to sample directly from the 1,536-well plates. Currently, commercially available 1,536-well plate auto samplers are not compatible with Waters LC/MS systems. The authors have modified their CTC PAL autosampler to support injection from up to twenty-four 1,536-well plates. This allows them to cherry-pick any sample from up to 36,864 wells on the autosampler. Because of its success at this Institute, sampling from 1,536-well plates has not only become the preferred method for LC/MS analysis from IC(50) plates but also become the standard format used for the handling of and the sampling from large combinatorial libraries.  相似文献   

2.

Background

Protein crystallisation screening involves the parallel testing of large numbers of candidate conditions with the aim of identifying conditions suitable as a starting point for the production of diffraction quality crystals. Generally, condition screening is performed in 96-well plates. While previous studies have examined the effects of protein construct, protein purity, or crystallisation condition ingredients on protein crystallisation, few have examined the effect of the crystallisation plate.

Methodology/Principal Findings

We performed a statistically rigorous examination of protein crystallisation, and evaluated interactions between crystallisation success and plate row/column, different plates of same make, different plate makes and different proteins. From our analysis of protein crystallisation, we found a significant interaction between plate make and the specific protein being crystallised.

Conclusions/Significance

Protein crystal structure determination is the principal method for determining protein structure but is limited by the need to produce crystals of the protein under study. Many important proteins are difficult to crystallise, so that identification of factors that assist crystallisation could open up the structure determination of these more challenging targets. Our findings suggest that protein crystallisation success may be improved by matching a protein with its optimal plate make.  相似文献   

3.
This report describes the development and validation of a robust robotic system that fully integrates all peripheral devices needed for the automated preparation of plasma samples by protein precipitation. The liquid handling system consisted of a Tecan Freedom EVO 200 liquid handling platform equipped with an 8-channel liquid handling arm, two robotic plate-handling arms, and two plate shakers. Important additional components integrated into the platform were a robotic temperature-controlled centrifuge, a plate sealer, and a plate seal piercing station. These enabled unattended operation starting from a stock solution of the test compound, a set of test plasma samples and associated reagents. The stock solution of the test compound was used to prepare plasma calibration and quality control samples. Once calibration and quality control samples were prepared, precipitation of plasma proteins was achieved by addition of three volumes of acetonitrile. Integration of the peripheral devices allowed automated sequential completion of the centrifugation, plate sealing, piercing and supernatant transferral steps. The method produced a sealed, injection-ready 96-well plate of plasma extracts. Accuracy and precision of the automated system were satisfactory for the intended use: intra-day and the inter-day precision were excellent (C.V.<5%), while the intra-day and inter-day accuracies were acceptable (relative error<8%). The flexibility of the platform was sufficient to accommodate pharmacokinetic studies of different numbers of animals and time points. To the best of our knowledge, this represents the first complete automation of the protein precipitation method for plasma sample analysis.  相似文献   

4.
In bioprocess development, the 96-well plate format has been widely used for high-throughput screening of production cell line or culture conditions. However, suspension cell cultures in conventional 96-well plates often fail to reach high cell density under normal agitation presumably due to constraints in oxygen transfer. Although more vigorous agitation can improve gas transfer in 96-well plate format, it often requires specialized instruments. In this report, we employed Fluorinert, a biologically inert perfluorocarbon, to improve oxygen transfer in 96-well plate and to enable the growth of a Chinese Hamster Ovary cell line expressing a recombinant monoclonal antibody. When different amounts of Fluorinert were added to the cell culture medium, a dose-dependent improvement in cell growth was observed in both conventional and deep square 96-well plates. When sufficient Fluorinert was present in the culture, the cell growth rate, the peak cell density, and recombinant protein production levels achieved in deep square 96-wells were comparable to cultures in ventilated shake flasks. Although Fluorinert is known to dissolve gases such as oxygen and CO(2), it does not dissolve nor extract medium components, such as glucose, lactate, or amino acids. We conclude that mixing Fluorinert with culture media is a suitable model for miniaturization of cell line development and process optimization. Proper cell growth and cellular productivity can be obtained with a standard shaker without the need for any additional aeration or vigorous agitation.  相似文献   

5.
Cancer cell spheroids present a relevant in vitro model of avascular tumors for anti-cancer drug testing applications. A detailed protocol for producing both mono-culture and co-culture spheroids in a high throughput 96-well plate format is described in this work. This approach utilizes an aqueous two-phase system to confine cells into a drop of the denser aqueous phase immersed within the second aqueous phase. The drop rests on the well surface and keeps cells in close proximity to form a single spheroid. This technology has been adapted to a robotic liquid handler to produce size-controlled spheroids and expedite the process of spheroid production for compound screening applications. Spheroids treated with a clinically-used drug show reduced cell viability with increase in the drug dose. The use of a standard micro-well plate for spheroid generation makes it straightforward to analyze viability of cancer cells of drug-treated spheroids with a micro-plate reader. This technology is straightforward to implement both robotically and with other liquid handling tools such as manual pipettes.  相似文献   

6.
There is a pressing need to develop new antimicrobial drugs because of the increasing resistance of pathogenic bacteria to existing antibiotics. The preliminary development and validation of a novel methodology for the high-throughput screening of antimicrobial compounds and inhibitors of bacterial motility is described. This method uses a bacterial motility swarming agar assay, combined with the use of offset inoculation of the wells in a standard, clear, 96-well plate, to enable rapid screening of compounds for potential antibiotic and antimotility properties with a standard absorbance microplate reader. Thus, the methodology should be compatible with 96-well laboratory automation technology used in drug discovery and chemical biology studies. To validate the screening method, the Genesis Plus structurally diverse library of 960 biologically active compounds was screened against a motile strain of the gram-negative bacterial pathogen Salmonella typhimurium. The average Z' value for the positive and negative motility controls on all 12 compound plates was 0.67 +/- 0.14, and the signal-to-baseline ratio calculated from the positive and negative controls was 5.9 +/- 1.1. A collection of 70 compounds with well-known antimicrobial properties was successfully identified using this assay.  相似文献   

7.
The use of automated protein precipitation by filtration in the 96-well format as a rapid sample preparation technique for high throughput bioanalysis using liquid chromatography tandem mass spectrometry is reported. A robotic sample processor is used to aspirate sequentially a plasma sample and acetonitrile separated by air gaps. These are then mixed by being dispensed into individual channels of a 96-well filter block. The resulting supernatant is separated from the precipitated plasma proteins by the application of gentle vacuum using a custom manifold. The filtered supernatants are collected into a deep well microtitre plate, evaporated to dryness using a heated 96-well dry down station and reconstituted in water prior to analysis. The efficiency of the extraction procedure is measured by the Lowry method for determining protein concentration. This method was used to optimise both the volume and the order of reagent addition, and to compare several prototype 96-well filter blocks. Using the optimised procedure a specific, precise and accurate method was developed for the β-agonist salbutamol in rabbit plasma with a calibration range of 1 to 100 ng/ml from 100 μl of sample.  相似文献   

8.
We describe a system that applies image processing and robotic techniques to automatically pick individual colonies from square petri dishes and array them in 96-well microtiter plates. Digital images of the colony distribution in the dishes are acquired using a video camera and frame buffer. Commercial image processing software is used to identify individual colonies and determine their locations. A Hewlett-Packard Microassay System robot reads the resulting coordinate file for each dish, picks cells from each identified colony and transfers the cells into a microtiter plate well. A disposable pipet tip is used as the sterile implement for colony picking. Custom holders position the dishes accurately and provide common coordinate systems for imaging and picking. The system is calibrated to account for the depth of agar in the dishes. The robot can process up to 10 dishes and 20 plates (1920 colonies) in a single run. It has successfully arrayed a cosmid library of the S. pombe genome consisting of approximately 6000 colonies in 30 petri dishes in about 40 hours of robot time. Future enhancements to the system are discussed.  相似文献   

9.
We developed an automated, high-throughput, bioluminescence-monitoring apparatus that can monitor 1920 individual plant seedlings under uniform light conditions. The apparatus is composed of five units: (i) a plate platform that can hold 20 96-well microplates under uniform light conditions, (ii) a scintillation counter, (iii) a robot that conveys plates between the plate platform and a scintillation counter, (iv) a sequence controller, and (v) an external computer that collects and analyzes bioluminescence data automatically. The apparatus gave reproducible and reliable results for both bioluminescence photon counts and period length of bioluminescence rhythms; neither was affected by the well position in a plate or the plate position on the platform. The apparatus is a powerful tool for both large-scale detailed analysis of gene expression and large-scale screening of mutants.  相似文献   

10.
Biological samples are normally collected and stored frozen in capped tubes until analysis. To obtain aliquots of biological samples for analysis, the sample tubes have to be thawed, uncapped, samples removed and then recapped for further storage. In this paper, we report an automated method of sample transfer devised to eliminate the uncapping and recapping process. This sampling method was incorporated into an automated liquid-liquid extraction procedure of plasma samples. Using a robotic system, the plasma samples were transferred directly from pierceable capped tubes into microtubes contained in a 96-position block. The aliquoted samples were extracted with methyl-tert-butyl ether in the same microtubes. The supernatant organic layers were transferred to a 96-well collection plate and evaporated to dryness. The dried extracts were reconstituted and injected from the same plate for analysis by liquid chromatography with tandem mass spectrometry.  相似文献   

11.
Three extraction procedures were developed for the quantitative determination of a carboxylic acid containing analyte (I) in human plasma by high-performance liquid chromatography (HPLC) with negative ion electrospray tandem mass spectrometry (MS–MS). The first procedure was based on the manual liquid–liquid extraction (LLE) of the acidified plasma samples with methyl tert.-butyl ether. The second procedure was based on the automation of the manual LLE procedure using 96-well collection plates and a robotic liquid handling system. The third approach was based on automated solid-phase extraction (SPE) using 96-well SPE plates and a robotic liquid handling system. A lower limit of quantitation of 50 pg/ml was achieved using all three extraction procedures. The total time required to prepare calibration curve standards, aliquot the standards and plasma samples, and process a total of 96 standards and samples by manual LLE was three-times longer than the time required for 96-well SPE or 96-well LLE (4 h, 50 min vs. 1 h, 43 min). Even more importantly, the time the bioanalyst physically spent on the 96-well LLE or 96-well SPE procedure was only a small fraction of the time spent on the manual LLE procedure (<10 min vs. 4 h, 10 min). It should be noted that the 96-well SPE procedure incorporated the two steps of evaporation of the eluates to dryness and subsequent reconstitution of the dried extract. The total time required for the 96-well SPE could be reduced by 50% if the eluates were injected directly, eliminating the drying and reconstitution steps, which is achievable when sensitivity is less of an issue.  相似文献   

12.
Aldosterone plays a key role in the pathogenesis of hypertension, congestive heart failure, and chronic kidney disease. Aldosterone biosynthesis involves three membrane-bound enzymes: aldosterone synthase, adrenodoxin, and adrenodoxin reductase. Here, we report the development of a mass spectrometry-based high-throughput whole cell-based assay for aldosterone synthesis. A human adrenal carcinoma cell line (H295R) overexpressing human aldosterone synthase cDNA was established. The production of aldosterone in these cells was initiated with the addition of 11-deoxycorticosterone, the immediate substrate of aldosterone synthase. An automatic liquid handler was used to gently distribute cells uniformly to well plates. The adaption of a second automated liquid handling system to extract aldosterone from the cell culture medium into organic solvent enabled the development of 96- and 384-well plate formats for this cellular assay. A high-performance liquid chromatography–tandem mass spectrometry method was established for the detection of aldosterone. Production of aldosterone was linear with time and saturable with increasing substrate concentration. The assay was highly reproducible with an overall average Z′ value = 0.49. This high-throughput assay would enable high-throughput screening for inhibitors of aldosterone biosynthesis.  相似文献   

13.
Although it is accepted that trifluoroacetic acid (TFA) can cause suppression of an analyte during LC/MS analysis, this paper presents a relatively sensitive gradient method that uses a TFA mobile phase for the improved quantification of small, polar drug-like compounds. The described method was developed in a discovery drug metabolism and pharmacokinetics (DMPK) laboratory for the screening measurement of compound concentrations to calculate PK parameters and CNS exposure of compounds from a chemical series that had poor chromatography under generic methods using formic acid mobile phase. The samples were collected by a Culex automated sampling unit, and the plasma proteins were precipitated by a Tecan robot in 96-well plates. After centrifugation, the supernatant was removed, dried down using a SPE-Dry unit, and the samples were reconstituted in aqueous buffer on the robot. The samples were analyzed on an Agilent LC/MSD using a 5-min gradient on a 5 cm phenyl column. No additional steps, such as the "TFA-fix", were necessary. Although sample batches were analyzed over 6h, no drift or degradation of signal was observed. The improved chromatography resulted in a method that was selective, rugged, and had a dynamic range from 5 to 20,000 nM, which was sufficient to quantitate low volume, serial plasma samples collected out to 8 h postdose.  相似文献   

14.
In traditional screening with 96-well plates, microliters of substrates are consumed for each reaction. Further miniaturization is limited by the special equipment and techniques required to dispense nanoliter volumes of fluid. Plug-based microfluidics confines reagents in nanoliter plugs (droplets surrounded by fluorinated carrier fluid), and uses simple pumps to control the flow of plugs. By using cartridges pre-loaded with nanoliter plugs of reagents, only two pumps and a merging junction are needed to set up a screen. Screening with preloaded cartridges uses only nanoliters of substrate per reaction, and requires no microfabrication. The low cost and simplicity of this method has the potential of replacing 96-well and other multi-well plates, and has been applied to enzymatic assays, protein crystallization and optimization of organic reactions.  相似文献   

15.
The usage of standard 96 well microplates for the screening of crystallization conditions of recombinant proteins offers several advantages when compared to commonly used crystallization plate formats. The adoption of robotic technology for plate and glass slide preparation within a "hanging drop" vapour diffusion crystallization experiment enables to work with an increased throughput at reduced costs. In addition to commercial pipetting devices with a 96-channel aspirator/dispenser, solenoid ink-jet technology was applied to form 250 nl droplets with a diameter of approximately 1 mm. This allows miniaturization of crystallization screening set-ups with an estimated ten-fold cost reduction when compared to commonly used 24 well plates.  相似文献   

16.
We have developed a robotic system for an automated parallel cell cultivation process that enables screening of induction parameters for the soluble expression of recombinant protein. The system is designed for parallelized and simultaneous cultivation of up to 24 different types of cells or a single type of cell at 24 different conditions. Twenty-four culture vessels of about 200 ml are arranged in four columns x six rows. The system is equipped with four independent thermostated waterbaths, each of which accommodates six culture vessels. A two-channel liquid handler is attached in order to distribute medium from the reservoir to the culture vessels, to transfer seed or other reagents, and to take an aliquot from the growing cells. Cells in each vessel are agitated and aerated by sparging filtered air. We tested the system by growing Escherichia coli BL21(DE3) cells harboring a plasmid for a model protein, and used it in optimizing protein expression conditions by varying the induction temperature and the inducer concentration. The results revealed the usefulness of our custom-made cell cultivation robot in screening optimal conditions for the expression of soluble proteins.  相似文献   

17.
A microbroth chemiluminometric version of the biochemical induction assay (BIA) was developed using a chemiluminescent substrate widely used to detect beta-galactosidase in high-throughput screening (HTS) laboratories. The assay was run in both 96-well and 384-well plate formats using the Zymark RapidPlate liquid handling system to transfer samples and reagents. Chemiluminescence was read using the Victor-2 multilabel counter. The new microbroth chemiluminometric method, the CBIA, allowed rapid screening of samples, crude extracts, and pure compounds for their DNA-damaging effects in bacteria. In screening a small subset of our natural products library samples by the agar plate BIA and the CBIA, the latter yielded a higher hit rate, suggesting it is more sensitive than the agar plate assay. The CBIA was unaffected by the colored samples often encountered during screening of crude natural products extracts.  相似文献   

18.
AequoScreen, a cellular aequorin-based functional assay, has been optimized for luminescent high-throughput screening (HTS) of G protein-coupled receptor (GPCRs). AequoScreen is a homogeneous assay in which the cells are loaded with the apoaequorin cofactor coelenterazine, diluted in assay buffer, and injected into plates containing the samples to be tested. A flash of light is emitted following the calcium increase resulting from the activation of the GPCR by the sample. Here we have validated a new plate reader, the Hamamatsu Photonics FDSS6000, for HTS in 96- and 384-well plates with CHO-K1 cells stably coexpressing mitochondrial apoaequorin and different GPCRs (AequoScreen cell lines). The acquisition time, plate type, and cell number per well have been optimized to obtain concentration-response curves with 4000 cells/well in 384-well plates and a high signal:background ratio. The FDSS6000 and AequoScreen cell lines allow reading of twenty 96- or 384-well plates in 1 h with Z' values of 0.71 and 0.78, respectively. These results bring new insights to functional assays, and therefore reinforce the interest in aequorin-based assays in a HTS environment.  相似文献   

19.
An analytical method was developed for the determination of ximelagatran, an oral direct thrombin inhibitor, its active metabolite melagatran, and the two intermediate metabolites, OH-melagatran and ethyl-melagatran in human plasma. Extraction of plasma was carried out on a mixed mode bonded sorbent material (C8/SO(3)(-)). All four analytes, including their isotope-labelled internal standards, were eluted at high ionic strength with a mixture of 50% methanol and 50% buffer (0.25 M ammonium acetate and 0.05 M formic acid, pH 5.3) with an extraction recovery above 80%. The extracts were demonstrated to be clean in terms of a low concentration of albumin and lysoPC. The sample extraction was fully automated and performed in 96-well plates using a Tecan Genesis pipetting robot. Analysis of the extracts were performed with liquid chromatography followed by positive electrospray ionization mass spectrometry. The low organic content and the low pH of the extracts allowed for, after dilution 1:3 with buffer, direct injection onto the LC-column. The four analytes were separated on a C18 analytical LC-column using gradient elution with the acetonitrile concentration varying from 10 to 30% (v/v) and the ammonium acetate and acetic acid concentration kept constant at 10 and 5 mmol/L, respectively, at a flow rate of 0.75 mL/min. Linearity was achieved over the calibrated range 0.010-4.0 micromol/L with accuracy and relative standard deviation in the range 96.9-101.2% and 6.6-17.1%, respectively at LLOQ, and in the range 94.7-102.6% and 2.7-6.8%, respectively at concentrations above 3 x LLOQ. The method replaces a manual method, and displays the advantages of having a fully automated sample clean-up, no evaporation/reconstitution step, high recovery, and complete LC-separation of all four analytes.  相似文献   

20.
A liquid chromatography-tandem mass spectrometry method was developed for the analysis of sildenafil (SIL) and its metabolite desmethylsildenafil (DMS) in human plasma. Samples were accurately transferred to 96-well plates using a liquid handler (Multiprobe II). Solid-phase extraction was carried out on a 96-channel programmable liquid handling workstation (Quadra 96) using a C8 and cation-exchange mixed-mode sorbent. The extract was injected onto a silica column with an aqueous-organic mobile phase, a combination that was novel for improving the method sensitivity. The low limit of quantitation was 1.0 ng/ml for both SIL and DMS. The method was validated to meet the criteria of current industrial guidance for quantitative bioanalytical methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号