1.
An ion-pairing high-performance liquid chromatographic method for the determination of N-acetylaspartate and N-acetylglutamate using a C-18 column and a UV detection at 210 nm wavelength, by means of a diode array detector, is presented. A buffer containing 2.8 mM tetrabutylammonium hydroxide, 25 mM KH(2)PO(4), 1.25% methanol, pH 7. 00, is utilized for the isocratic separation of these N-acetylated amino acids, at a flow rate of 1 ml/min and a column temperature of 23 degrees C. The suitability of this chromatographic separation (without additional chromatographic steps prior to HPLC assay) to monitor variations both of N-acetylaspartate and of N-acetylglutamate in perchloric acid brain extracts from rats subjected to the impact acceleration model of diffuse brain injury is also reported. According to the data presented, this HPLC method allows the separation of the two N-acetylated amino acids considered from the many possible interfering compounds, commonly present in extracts of cerebral tissue, which have high extinction coefficients at 210 nm wavelength. Values of N-acetylaspartate and N-acetylglutamate determined by this method showed that cerebral trauma negatively affects both compounds, according to the severity of trauma itself.  相似文献   

2.
The phenylthiohydantoin (PTH) derivatives of protein amino acids have been separated by reverse-phase high performance liquid chromatography (HPLC) on a fully end-capped C18 column using an isocratic solvent system. The developing solvent was 0.01 M sodium acetate buffer (pH 4.5) containing 39.5% acetonitrile and 0.02% sodium dodecylsulfate (SDS). With an automated liquid chromatography equipped with a dual-channel detector, operating at 254 and 313 nm, the present isocratic separation system was quite useful for routine microanalysis of PTH-amino acids released with a "gas-phase" sequencer. The time for one run was approximately 23 min and the limit of analysis approximately 2.5 pmol of a PTH-amino acid.  相似文献   

3.
A micro-method adaptation of Borchers' cuprizone amino acid assay was ideal for the rapid determination of the concentrations and, thus the utilization, of sole amino acids in microbiological cultures. While the method has been in the literature for ≈ 30 yr, it does not seem to have been widely used. This communication report on the usefulness of the method in routine microbiological analyses and shows that interfering compounds were generally not a problem. Standard medium components were shown either not to interfere at all, or to be easily corrected for using a medium blank. A wide range of amino acids and a number of other N-containing compounds could be measured. The accuracy of the method was estimated at ±4.5%. a Thermus strain was grown on -glutamate and substrate utilization was followed using this method.  相似文献   

4.
Reversed phase microcolumns have been widely used for peptide pretreatment to desalt and remove interferences before tandem LC–MS in proteomics studies. However, few studies have characterized the effects of experimental parameters as well as column characteristics on the composition of identified peptides. In this study, several parameters including the concentration of ACN in washing buffer, the microcolumn's purification effect, the peptide recovery rate, and the dynamic‐binding capacity were characterized in detail, based upon stable isotope labeling by amino acids in a cell culture quantitative approach. The results showed that peptide losses can be reduced with low ACN concentration in washing buffers resulting in a recovery rate of approximately 82%. Furthermore, the effects of ACN concentration and loading amount on the properties of identified peptides were also evaluated. We found that the dynamic‐binding capacity of the column was approximately 26 μg. With increased loading amounts, more hydrophilic peptides were replaced by hydrophobic peptides.  相似文献   

5.
A new approach for the separation of 6-aminoquinolyl-carbamyl (AQC)-derivatized amino acids has been proposed. The chromatography used ion-pairing mechanism to increase the method selectivity. Mobile phase was based on triethylamine buffer containing N,N-dimethyloctylamine as a modifier. A number of factors, buffer composition and pH, counterion concentration, temperature and acetonitrile gradient profile, were optimized to achieve final chromatographic conditions. With the presented analytical method, the separation and identification of 34 AQC-amino acids and amino compounds present in human plasma is possible. The results of validation proved the applicability of the method for quantification of 27 amino acids in biological samples. The ultrafiltration proposed as deproteinization procedure gave repeatable and reliable results for the amino acids under investigation. This method introduced in routine testing can be a suitable tool for amino acid profiling in plasma including all aspects of clinical application.  相似文献   

6.
本文报告了采用高效液相色谱法反相梯度洗脱,邻苯二甲醛和β-巯基乙醇柱前衍生化,荧光检测分血浆游离氨基酸。实验采用线性洗脱,在50分钟内可同时测定18种氨基酸,血浆样品的预处理简单,衍生化反应的时间仅需1分30秒,血浆样品的实际进样量少于1μl。本测定方法的精确度高,各个氨基酸保留时间的变异系数平均为0.89%±0.45%(SD),峰面积的变异系数平均为2.06%±1.76%(SD),各个氨基酸的浓度在15—150μmol/L的范围中,线性关系的相关系数平均为0.985±0.0305(SD)。准确性好,各个氨基酸的回收率平均为97.6%±5.1%(SD)。实验还讨论了氨基酸分离时溶液pH值、柱温、离心速度等因素对分析结果的影响。  相似文献   

7.
A gas chromatographic procedure was developed for determination of minute amounts of free amino acids in natural waters and laboratory models simulating biological systems. Sample pretreatment included removal of interfering organic substances by chloroform extraction and isolation of amino acids by cation exchange. Amino acids were converted to their N-heptafluorobutyryl isobutyl ester derivatives in glass capillary tubes, permitting considerable concentration of the sample prior to gc injection. The derivatives of 19 amino acids were successfully separated on either a glass column packed with a mixture of OV-101 and OV-17 on Chromosorb W, a glass capillary column coated with OV-101, or a support-coated capillary column supported with SE-30. One to five nanograms of individual amino acids were detected using flame ionization detector. The detection limit was reduced more than 100-fold using the electron capture detector and more than 1000-fold by mass fragmentography. The procedure allowed determination of less than 1 ppb of individual amino acids in lake and river water samples and was used to estimate the exeretion of free amino acids from microbial populations.  相似文献   

8.
A procedure was described for the rapid determination of glucosamine and galactosamine in total acid hydrolyzate of rat renal glomerular basement membrane (GBM) by the use of amino acid analyzer. Glucosamine and galactosamine, as well as other amino acids in glycoprotein hydrolyzate, were well identified and estimated simultaneously by using a short column of HITACHI I-PF-B spherical resin, eluted with a pH 6.09 buffer containing 8% methanol at 38°C.Total time consumed for elution of galactosamine was 60 min. This method is ideal for the separation of small amount of galactosamine from hydroxylysine-rich materials.  相似文献   

9.
本文报道了用2,4-二硝基氟苯柱前衍生反相高效液相色谱法测定氨基酸,15种常见的氨基酸可得到很好的分离。衍生物很稳定,在室温下保存两个月无明显变化,检测极限可达到5pmol。本法可应用于食品、药品等样品的氨基酸测定。  相似文献   

10.
The large-scale purification of plasmid DNA was achieved using fast protein liquid chromatography on a Hi-Load Q Sepharose column. This method allows for the purification of plasmids starting from crude plasmid DNA, prepared by a simple alkaline lysis procedure, to pure DNA in less than 5 h. In contrast to the previously described plasmid purification methods of CsCl gradient centrifugation or high-pressure liquid chromatography, this method does not require the use of any hazardous or expensive chemicals. More than 100 plasmids varying in size from 3 to 15 kb have been purified using this procedure. A Mono Q Sepharose column was initially used to purify plasmids smaller than 8.0 kb; however, a Hi-Load Q Sepharose column proved more effective with plasmids larger than 8 kb. The loading of plasmids larger than 8 kb on the Mono Q column resulted in a high back pressure and the plasmid DNA could not be eluted from the column. Thus, for routine purification we utilize the Hi-Load Q Sepharose column. Plasmids purified by this method had purity, yield, and transfection efficiency in mammalian cells similar to those of plasmids purified by CsCl density gradient centrifugation.  相似文献   

11.
An amino acid analysis by reversed-phase high-performance liquid chromatography after precolumn derivatization with phenyl isothiocyanate was adapted to the determination of free amino acids in plasma or other biological fluids and in tissue homogenates. Preparation of samples included deproteinization by 3% sulphosalicylic acid, and careful removal under high vacuum of residual phenyl isothiocyanate after derivatization. A Waters Pico-Tag column (15 cm long) was used, immersed in a water-bath at 38°C. In rat or human plasma, separation of 23 individual amino acids, plus the unresolved pair tryptophan and ornithine, was obtained within 13 min. Including the time for column washing and re-equilibration, samples could be chromatographed at 23-min intervals. Variability was tested for each amino acid by calculating the coefficients of variation of retention times (less than 1% in the average) and peak areas (less than 4% for both intra-day and inter-day determinations). The linearity for each standard amino acid was remarkable over the concentration range 3–50 nmol/ml. The mean recovery of amino acid standards added to plasma prior to derivatization was 97 ± 0.8%, except for aspartate (82%) and glutamate (81%). This method is rapid (almost three samples per hour can be analysed, more than in any other reported technique), with satisfactory precision, sensitivity and reproducibility. Therefore, it is well suited for routine analysis of free amino acids in both clinical and research work.  相似文献   

12.
A procedure for peptide sequencing using an immobilized exopeptidase column directly coupled to a thermospray mass spectrometer is described. The amino acids sequentially released from the C-terminus of the peptide chain are directly introduced into a thermospray ion source by a flowing aqueous buffer. The buffer is essential for the direct production of ions from solution. The method eliminates the need to derivatize the amino acids for detection and, by comparison to standard injections, amino acid sequence information can be obtained in less than two minutes. With the present configuration, detection limits are typically in the low picomolar range.  相似文献   

13.
A fast HPLC method using a monolithic silica column was developed for the measurement of amino acids. The amino acids were pre-column derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) and separated on a monolithic silica column (MonoClad C18-HS, 250 mm × 3 mm I.D.). The separation of 19 NBD-amino acids was achieved within 18 min, which was only one-fifth of the time taken by the methods using a conventional particle-packed column, with the gradient elution of a mobile phase at the flow rate of 1.4 mL/min. The sensitivity was good with a limit of detection for the individual amino acids ranging from 2.94 to 53.4 fmol. The calibration curves for all the amino acids were found to be linear in the range of 200 fmol to 20 pmol with correlation coefficients of 0.997 or better. The analytical method was successfully applied to determine the amino acids in a mouse plasma sample.  相似文献   

14.
We report a three-phase chromatographic method for the separation and analysis of δ13C values of underivatized amino acids from biological proteins (keratin, collagen, and casein) using liquid chromatography-isotope ratio mass spectrometry (LC-IRMS). Both precision and accuracy of δ13C values for standard amino acid mixtures over the range of approximately 8 to 1320 ng of carbon per amino acid on the column were assessed. The precision of δ13C values of amino acids was found to be better at higher concentrations, whereas accuracy improved at lower concentrations. The optimal performance for this method was achieved with between 80 and 660 ng of carbon of each amino acid on the column. At amino acid amounts lower than 20 ng of carbon on the column, precision and accuracy may become compromised. The application of this new three-phase chromatographic technique will allow the analysis of δ13C of amino acids to be carried out as a routine method and benefit fields of research such as biomedicine, forensics, ecology, nutrition, and palaeodiet reconstruction in archaeology.  相似文献   

15.
Wang C  Zhang W  Song F  Liu Z  Liu S 《Amino acids》2012,42(5):1889-1895
The analysis by electrospray-ionization tandem mass spectrometry of amino acids with butyl esterification and isotopically labeled internal standard is routine in newborn screening laboratories worldwide. In the present study, we established a direct analysis method of higher accuracy that uses a non-deuterated internal standard. The automatic sampler and the pump of an LC apparatus were used to inject sample and mobile phase to MS, but no LC column was needed. The dry blood spot (DBS) material was prepared at levels of low, medium and high concentration; the running time was 1 min. In parallel to the new procedure, we applied the established method to analyze nine amino acids on DBS of healthy newborns and phenylketonuria newborns. The newly proposed method of product ion confirmation scan along with multiple reaction monitoring resulted in a very accurate identification of each amino acid. Our innovative protocol had high sensitivity and specificity in the analysis of cases of suspected metabolic diseases.  相似文献   

16.
A simple method for the determination of radioactivity of proline and hydroxyproline, particularly of small amounts, in hydrolysates of tissues is described. Specificity is assured by eliminating primary amino acids from the hydrolysates by deamination and then extraction before separation of proline from hydroxyproline by paper chromatography. Six to eight tissue samples may be compared simultaneously. The efficiency and reproducibility are good, as indicated by the use of labeled l-proline, labeled dl-hydroxyproline, a hydrolysate of a protein in which the amino acids (and proline) were labeled, and hydrolysates of tissues cultured in media containing radioactive l-proline. The method is particularly useful when ion-exchange column chromatography of amino acids is not in routine use.  相似文献   

17.
A sensitive and reproducible fully automated method for the determination of amino acids in plasma based on reversed-phase high-performance liquid chromatography and o-phthaldialdehyde pre-column derivatization is described. A 5-μm Spherisorb ODS 2 column (125 × 3 mm I.D.) was selected for routine determination. Over 40 physiological amino acids could be determined within 49 min (injection to injection) and 48 samples could be processed unattended. The coefficients of variation for most amino acids in plasma were below 4%. We were also able to measure trace amounts of amino acids in plasma normally not detected in a routine analysis. The results obtained with the method described compared favourably with those of conventional amino acid analysis (r = 0.997) and were in excellent agreement with those of other laboratories (r = 0.999).  相似文献   

18.
This study compared the effect of loading apoferritin either with ferrous ammonium sulfate in various buffers or with ceruloplasmin and chelated ferrous iron. It was shown that loading of apoferritin with ferrous ammonium sulfate was dependent on buffer and pH, and was directly related to the rate of iron autoxidation. The ceruloplasmin-dependent loading of apoferritin, however, was unaffected by these factors. Isoelectric focusing and amino acid analysis of the differently loaded ferritins showed that ferrous ammonium sulfate loading of apoferritin resulted in the depletion of the basic amino acids, lysine and histidine, probably as a result of protein oxidation. No significant differences in amino acid composition was noted for ceruloplasmin-loaded ferritin. Furthermore, ferritin loaded with ferrous ammonium sulfate released more iron than either native or ceruloplasmin-loaded ferritin when either paraquat or EDTA was used as an iron mobilizing agent. We suggest that the loading of apoferritin with ferrous ammonium sulfate occurred as a result of iron autoxidation and may result in oxidation of amino acids and loss of integrity of the protein, and that ceruloplasmin may act as a catalyst for the incorporation of iron into apoferritin in a manner more closely related to that occurring in vivo.  相似文献   

19.
The chiral selectivity of ristocetin A was examined in a countercurrent process in CE using a coated column to suppress electroosmotic flow. Excellent enantioseparations of several nonsteroidal antiinflammatories, dansylamino acids, dinitrophenyl‐derivatized amino acids, and other optically active compounds were achieved. The chiral selectivity of ristocetin A also was examined as a function of antibiotic concentration and pH. Enantioresolution was found to significantly improve with a slight increase in migration time upon increasing chiral selector concentration. Enantioselectivities were found to be greatly influenced by pH of the running buffer. Chirality 11:663–668, 1999. © 1999 Wiley‐Liss, Inc.  相似文献   

20.
An enzymatic method for hydrolyzing bovine milk proteins was developed. Purified milk proteins (alpha-lactalbumin, beta-lactoglobulin, and beta-casein) were hydrolyzed in 0.1 M Hepes buffer (pH 7.5) containing pronase E, aminopeptidase M, and prolidase at 37 degrees C for 20 h. Free glutamine and other amino acids were derivatized with phenylisothiocyanate and separated using a C18 Pico-Tag column. Amino acids were eluted from the column with an aqueous sodium acetate-acetonitrile gradient with detection at 254 nm. Glutamine recoveries from hydrolyzed alpha-lactalbumin, beta-lactoglobulin, and beta-casein were 78 +/- 4, 98 +/- 3, and 101 +/- 3% of the theoretical values, respectively. The recoveries of most amino acids were comparable with those obtained using acid hydrolysis, except for the recoveries of proline and acidic amino acids. These peptide bonds appeared to be resistant to enzymatic hydrolysis and also to inhibit the hydrolysis of adjacent amino acids. Free glutamine was found to be very stable (97% recovery) under the enzymatic hydrolysis conditions.  相似文献   