首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A series of 12 chiral arylcarboxylic acids were chromatographed on an immobilized human serum albumin chiral stationary phase (HSA-CSP). The effects of solute structure on chromatographic retentions and enantioselective separations were examined by linear regression analysis and the construction of quantitative structure-enantioselective retention relationships. Competitive displacement studies were also conducted using R-ibuprofen as the displacing agent. The results indicate that the enantioselective retention of the solutes takes place at the indole-benzodiazepine site (site II) on the HSA molecule and that chiral recognition is affected by the hydrophobicity and steric volume of the solutes. The displacement studies also identified a cooperative allosteric interaction induced by the binding of R-ibuprofen to site II. Chirality 9:178–183, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

2.
The enantioselective resolution of trans-stilbene oxide and of 23 chiral sulfoxides was investigated on cellulose and amylose tris(arylcarbamate) stationary phases coated on aminopropylated 7 μm spherical silica with 500 Å diameter pores. Cellulose tris-(3,5 dimethylphenylcarbamate) showed good resolving power for many of the sulfoxides and amylose tris-(3,5 dimethoxyphenylcarbamate) showed advantages for the resolution of certain sulfoxides which were not separated on other phases. © 1994 Wiley-Liss, Inc.  相似文献   

3.
Wang P  Liu D  Jiang S  Gu X  Zhou Z 《Chirality》2007,19(2):114-119
Amylopectin-tris(phenylcarbamate) was synthesized and coated to aminopropylsilica to prepare chiral stationary phase. The chiral separations of fungicide enantiomers were performed by the CSP using high-performance liquid chromatography. Mobile phase was n-hexane and isopropanol, and flow rate was 1.0 ml/min. Detection wavelength was 230 nm. The influence of the percentage of isopropanol in the mobile phase on the separations was studied. Twelve chiral fungicides were tested and seven of them were found to show stereoselectivity on the CSP. The enantiomers of metalaxyl and benalaxyl got near baseline separations and myclobutanil, hexconazole, tebuconazole, uniconazole, and paclobutrazol enantiomers were completely separated. The decreasing percentage of isopropanol in the mobile phase resulted in better separation and longer analysis time. The enantiomers were identified by a circular dichroism (CD) detector and the CD spectra of the individual enantiomers were also studied by online scanning.  相似文献   

4.
A stereospecific HPLC method for separation of Frovatriptan enantiomers in bulk drug and pharmaceutical formulations was developed and validated on a normal-phase amylose derivertized chiral column. The effects of the organic modifiers namely 2-propanol, ethanol and diethyl amine (DEA) in the mobile phase were optimized to obtain the best enantiomeric separation. Calibration curves were linear over the range of 200-6150 ng/mL, with a regression coefficient (R(2)) of 0.9998. The limit of detection (LOD) and limit of quantification (LOQ) were 65 ng/mL and 200 ng/mL, respectively. The method was accurate and precise and suitable for the intended purpose. Analysis results were compared with the results obtained by using a validated chiral CE method and found to be in very good agreement. This method can be successfully applied to the enantiomeric purity analysis of Frovatriptan in pharmaceutical bulk drug samples and formulations.  相似文献   

5.
The stereochemical separation of free and derivatized amino acids on active alpha-chymotrypsin bonded to silica is governed by two mechanisms based on the structure of the solutes or on the enzymatic activity of the enzyme. The deactivation of the hydrolytically active site of the enzyme demonstrated that a significant portion of the retention on this support is due to hydrophobic interactions at other sites. These sites appear to be stereoselective for the ester derivatives of amino acids but not for the other studied solutes.  相似文献   

6.
A chiral anion-exchanger stationary phase based on cinchonidine (CD) was developed. Two columns were packed with and without endcapping (EC) treatment (CD-chiral stationary phase[CD-CSP(EC)] and [CD-CSP], respectively) and studied for their ability to separate N-2,4-dinitrophenyl α-amino acids (DNP-amino acids) enantiomers over a temperature range of 10-40 °C with a hydro-organic buffer mobile phase. The more hydrophobic, endcapped stationary phase showed significantly larger retentive capacity than the non-endcapped one. The apparent thermodynamic transfer parameters of the enantiomers from the mobile to both CSPs were estimated from van't Hoff plots within the cited temperature range. Similar studies with two natural quinine-based columns (QN-CSP and QN-CSP(EC)) were previously reported. In this work, a critical comparison in the chiral recognition ability to DNP-amino acids of these cinchonidine and QN-based chiral columns was drawn. It has been found that QN-based CSPs show greater chiral recognition capability towards these derivatives than CD-CSPs. The influence of the QN methoxy group on the equilibrium constants of the enantioselective interaction between these DNP-amino acids with these two cinchona CSPs could be assessed.  相似文献   

7.
G T?r?k  A P?ter  D W Armstrong  D Tourw?  G T?th  J S?pi 《Chirality》2001,13(10):648-656
Direct high-performance liquid chromatographic chiral separation of numerous underivatized unnatural amino acids on a ristocetin A-bonded chiral stationary phase used in the reversed-phase and in the polar organic chromatographic modes is reported. The effects of different parameters such as mobile phase composition, temperature, and the structure of the analytes on the selectivity in both chromatographic modes are discussed. By variation of the parameters, the separation of the stereoisomers was optimized and, as a result, baseline resolution was achieved in most cases.  相似文献   

8.
Yubing Tang 《Chirality》1996,8(1):136-142
Eight randomly selected pharmaceuticals, which included ibuprofen, ketoprofen, albuterol, acebutolol, propafenone, betaxolol, methylphenidate, and homatropine, were directly separated on a cellulose tris(4-methylbenzoate) chiral stationary phase (CSP) without derivatization via normal phase mode HPLC. Enantioresolution was achieved by the optimization of the type and the ratio of mobile phase modifiers and additives. The modifiers included alcohols; the mobile phase additives were trifluoroacetic acid (TFA) and triethylamine (TEA). It was found that methanol and ethanol were superior to isopropanol as mobile phase modifiers for enhancing chiral separation of some of the chiral drugs. The results also demonstrated that TFA has a dominant effect on chiral separations for both acidic and basic chiral drugs, although for some basic drug such as homatropine, TEA was more beneficial at improving enantioseparation. The separation of acebutolol enantiomers was achieved for the first time by adding both TFA and TEA to the mobile phase. The purpose of this paper is to demonstrate that the applicability of cellulose based CSPs can be expanded by controlling the mobile phase compositions through the addition of trace amounts of achiral additives and the selection of the appropriate alcoholic modifier. © 1996 Wiley-Liss, Inc.  相似文献   

9.
We present a method for the enantioselective analysis of albendazole sulfoxide (ABZSO) in plasma for application in clinical pharmacokinetic studies. ABZSO enantiomers were separated on a 5-μm Chiralcel OB-H® column (4.6 × 150 mm) using hexane:ethanol (93:7, v/v) as the mobile phase and fluorescence detection. ABZSO was extracted with chloroform:isopropanol (8:2, v/v) from 500-μl aliquots of acidified plasma, with full drug recovery. The proposed method presented quantitation limits of 20 ng/ml for (−)ABZSO and 50 ng/ml for (+)ABZSO and was linear up to a concentration of 5,000 ng/ml of each enantiomer. Chirality 9:722–726, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

10.
Su X  Luo K  Xiang Q  Lan J  Xie R 《Chirality》2009,21(5):539-546
Two kinds of novel chiral molecular tweezers containing imidazoliums were synthesized from L-alanine, L-phenylalanine, and L-glutamic acid. They are constructed by the chiral imidazolium pincers and two different spacers which are 1,3-bis (bromomethyl)benzene and 2,6-bis(bromomethyl)pyridine, respectively. The enantioselective recognition of L- and D-amino acid derivatives by these molecular tweezers was investigated by UV spectroscopic titration experiments and good enantioselectivities were obtained, which are highly sensitive to whether the spacer has the binding site and the pincers has the other aromatic rings besides imidazolium ring. The host molecular 3b.2PF6- showed remarkable enantioselectivity for N-Boc protected histidine methyl ester, affording K(L)/K(D) of 5.10.  相似文献   

11.
A novel enantioselective potentiometric sensor was constructed based on optical active polyaniline (PAn) films. The sensor with high stability showed discrimination behavior toward one isomer of racemic phenylalanine (Phe). The (-) or (+) PAn-based electrodes exhibited an excellent Nernstian slope of approximately 60 mV per decade for L-Phe or D-Phe, respectively. In addition, when the sensor was exposed to the mixture of enantiomers, the slope of the response changed along with their proportions, which would be employed as an index of the enantiomeric purity of the mixture. At last, the mechanism of chiral discrimination for Phe was discussed.  相似文献   

12.
A macrocyclic glycopeptide antibiotic containing a hydrophobic “tail” is covalently attached to silica gel via linkage chains. This material is extensively evaluated as a chiral stationary phase (CSP) for HPLC. The relevant structural features of the teicoplanin molecule which make it an effective chiral selector are discussed. The teicoplanin CSP appears to have excellent enantioselectivity for native amino acids, peptides, α-hydroxycarboxylic acids, and a variety of neutral analytes including cyclic amides and amines. Enantio-separations can be achieved in the reversed phase, normal phase, and “polar-organic” modes. This chiral selector is stable and the integrity of the CSP is excellent in all separation modes. Hence it can be considered a highly effective multimodal column. Optimization of these separations is discussed in terms of both selectivity and efficiency. Results indicate that the surface loading of the chiral selector affects all relevant separation parameters. A hypothesis is proposed to explain the enhanced efficiency obtained when using teicoplanin CSPs with higher surface coverage. It appears that teicoplanin is a widely applicable, highly effective chiral selector for HPLC enantioseparations. © 1995 Wiley-Liss, Inc.  相似文献   

13.
Chiral separation by normal phase high performance liquid chromatography is one of the most powerful technique to quantify the chiral purity of the compounds. In this study, a novel, simple, and specific analytical method was proposed to ascertain the chiral purity of alvimopan (ALV). The normal phase HPLC method was developed based on cellulose tris (3,5‐dichlorophenylcarbamate) stationary phase. The separation of ALV isomers achieved by using column CHIRALPAK IC (250 × 4.6 mm, 5 μm), mobile phase n‐hexane: isopropyl alcohol: ethanol: diethylamine (650:200:150:5 v/v), column oven temperature 30°C, flow rate 1.0 mL min?1, injection volume was 10 μL, chromatographic response monitored at 273 nm. The developed method was validated as per the ICH guidelines and found precise, accurate, and linear. The advantage of the method is a good separation of ALV isomers within 35 minutes of the analysis time. Therefore, this method is suitable for routine determination of chiral purity of ALV active pharmaceutical ingredient.  相似文献   

14.
We present a method for the enantioselective analysis of propafenone in human plasma for application in clinical pharmacokinetic studies. Propafenone enantiomers were resolved on a 10-μm Chiralcel OD-R column (250×4.6 mm I.D.) after solid-phase extraction using disposable solid-phase extraction tubes (RP-18). The mobile phase used for the resolution of propafenone enantiomers and the internal standard propranolol was 0.25 M sodium perchlorate (pH 4.0)–acetonitrile (60:40, v/v), at a flow-rate of 0.7 ml/min. The method showed a mean recovery of 99.9% for (S)-propafenone and 100.5% for (R)-propafenone, and the coefficients of variation obtained in the precision and accuracy study were below 10%. The proposed method presented quantitation limits of 25 ng/ml and was linear up to a concentration of 5000 ng/ml of each enantiomer.  相似文献   

15.
Enantioselective HPLC methods have been developed for the resolution of (RS)-2-phenylcyclohexanone (compound 1) and (RS)-2-phenyltetrahydropyran-4-one (compound 4) and the diastereoselective and enantioselective separations of their respective cis- and trans-alcohols; reduction of compound 1 yields trans- and cis-2-phenyl-1-cyclohexanol (compounds 2 and 3, respectively) and reduction of compound 4 yields trans- and cis-2-phenyl-tetrahydropyran-4-ol (compounds 5 and 6, respectively). Compounds 1, 2, and 3 were stereochemically resolved using a chiral stationary phase (CSP) based upon amylose tris(3,5-dimethylphenyl carbamate) coated on 10 μm silica-gel (Chiralpak AD-CSP). Compounds 4, 5, and 6 were stereochemically resolved on a coupled column system where a column containing a CSP based upon cellulose tris(3,5-dimethylphenyl carbamate) coated on 5 μm silica (Chiralcel OD-H-CSP) was coupled in series to the AD-CSP. The strategy employed in the identification of the peaks in the respective chromatograms is also discussed in this presentation. Chirality 8:551–555, 1996. © 1997 Wiley-Liss, Inc.  相似文献   

16.
A comparison of the enantiomeric resolution of (+/-)-threo-methylphenidate (MPH) (Ritalin) was achieved on different polysaccharide based chiral stationary phases. The mobile phase used was hexane-ethanol-methanol-trifluoroacetic acid (480:9.75:9.75:0.5, v/v/v/v). Benzoic acid and phenol were used as the mobile phase additives for the enantiomeric resolution of MPH on Chiralcel OB column only. The alpha values for the resolved enantiomers were 1.34, 1.29, 1.30, and 1.24 on Chiralpak AD, Chiralcel OD, Chiralcel OB (containing 0.2 mM benzoic acid in mobile phase), and Chiralcel OB (containing 0.2 mM phenol in mobile phase) columns, respectively. The R(s) values were 1.82, 1.53, 1.19, and 1.10 on Chiralpak AD, Chiralcel OD, Chiralcel OB (containing 0.2 mM benzoic acid in mobile phase), and Chiralcel OB (containing 0.2 mM phenol in mobile phase), respectively. The role of benzoic acid and phenol as mobile phase additives is discussed.  相似文献   

17.
Iwaniuk DP  Bentley KW  Wolf C 《Chirality》2012,24(7):584-589
Enantioselective induced circular dichroism analysis of amino alcohols has been accomplished using a conformationally flexible arylacetylene-based probe exhibiting two terminal aldehyde groups. The chirality of the amino alcohol substrates is imprinted on the stereodynamic receptor upon [1 + 2] condensation, which ultimately generates a strong chiroptical response. The distinct induced circular dichroism effects of the diimines obtained can be used for enantioselective sensing and enantiomeric excess determination of a wide range of substrates.  相似文献   

18.
Penbutolol is a β-adrenoceptor blocking agent, and it contains the clinically relevant (?)-S-enantiomer. It was reported that the (+)-R-enantiomer of penbutolol is pharmacologically 50 times less active than the (?)-S-isomer in β-sympatholysis and without intrinsic sympathomimetic activity and refractory period in the heart muscle. Furthermore, the (+)-R-enantiomer does possess mutagenic activity. A high-performance liquid chromatographic (HPLC) method is described for direct identification, stereochemical separation, and quantitation of (+)-R-enantiomer in the clinically used (?)-S-isomer. The method involves the use of cellulose tris-3,5-dimethylphenyl carbamate chiral stationary phase coated on silica gel (OD-Chiralcel column). The capacity factors (k′) for the first eluted enantiomer and stereochemical separation factor (α) obtained were 1.32 and 1.98, respectively. The maximum stereochemical resolution factor (R) was 5.05. The method could be applied for optical purity determination of (?)-(S)-penbutolol in pharmaceutical formulation to detect for the presence of the undesirable (+)-R-enantiomer.  相似文献   

19.
Mayani VJ  Abdi SH  Mayani SV  Kim HC  Park SK 《Chirality》2011,23(4):300-306
In modern chromatography, chiral stationary phase (CSP) and enantiomer self-disproportionation (ESD) are new inventions of packing material offer a guarantee for a successful enantiomeric separation. All CSPs were synthesized by chemical bonding of the relevant organic moieties onto a porous parent silica material for the separation of various racemic mixtures whereas achiral silica matrix was used for separation of non-racemic mixtures in ESD. Our present study provides to establish an understanding on the entire enantio-selective profile of amino alcohol based CSP as well as ESD and their precise utilization for high success rates for selective enantiomer separation with its appropriateness.  相似文献   

20.
In this study, tert-butyl carbamoylated quinine as chiral selector was immobilized on nonporous silica (NPS) 1.5 μm particles developed by MICRA, and this new chiral stationary phase (CSP) was packed into a 3.3 cm column (4.6 mm ID). A series of various N-protected α-amino acids was chosen as chiral selectands, including 3.5-dinitrobenzyloxycarbonyl amino acids (DNZ-AAs). In order to optimize the chromatographic conditions with this novel CSP and to apply it to the resolution of acidic analytes the following parameters have been varied and studied: pH of the mobile phase, buffer concentration, and percentage of methanol or acetonitrile in the mobile phase. DryLabR software was applied to optimize enantioseparation by simulating chromatographic functions of experimental conditions for isocratic and/or gradient runs. Thus, we were able to resolve a set of test compounds within several minutes, whereby our attention was particularly drawn to the resolution of DNZ-AA derivatives. Chirality 9:157–161, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号