首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A beacon aptamer-based biosensor for the detection of thrombin was developed using electrochemical transduction method. Gold surface was modified with a beacon aptamer covalently linked at 5'-terminus with a linker containing a primary aliphatic amine. Methylene blue (MB) was intercalated into the beacon sequence, and used as an electrochemical marker. When the beacon aptamer immobilized on gold surface encounters thrombin, the hairpin forming beacon aptamer is conformationally changed to release the intercalated MB, resulting a decrease in electrical current intensity in voltamogram. The peak signal of the MB is clearly decreased by the binding of thrombin onto the beacon aptamer. The linear range of the signal was observed between 0 and 50.8 nM of thrombin with 0.999 correlation factor. This method was able to linearly and selectively detect thrombin with a detection limit of 11 nM.  相似文献   

2.
Aptamer beacons for the direct detection of proteins.   总被引:9,自引:0,他引:9  
We have designed a new class of molecules, which we term aptamer beacons, for detecting a wide range of ligands. Similar to molecular beacons, aptamer beacons can adopt two or more conformations, one of which allows ligand binding. A fluorescence-quenching pair is used to report changes in conformation induced by ligand binding. An anti-thrombin aptamer was engineered into an aptamer beacon by adding nucleotides to the 5'-end which are complementary to nucleotides at the 3'-end of the aptamer. In the absence of thrombin, the added nucleotides will form a duplex with the 3'-end, forcing the aptamer beacon into a stem-loop structure. In the presence of thrombin, the aptamer beacon forms the ligand-binding structure. This conformational change causes a change in the distance between a fluorophore attached to the 5'-end and a quencher attached to the 3'-end. Aptamer beacon can be a sensitive tool for detecting proteins and other chemical compounds.  相似文献   

3.
Cho M  Kim Y  Han SY  Min K  Rahman MA  Shim YB  Ban C 《BMB reports》2008,41(2):126-131
The folding of aptamer immobilized on an Au electrode was successfully detected using label-free electrochemical methods. A thrombin binding DNA aptamer was used as a model system in the presence of various monovalent cations. Impedance spectra showed that the extent to which monovalent cations assist in folding of aptamer is ordered as K(+) > NH(4)(+) > Na(+) > Cs(+). Our XPS analysis also showed that K(+) and NH(4)(+) caused a conformational change of the aptamer in which it forms a stable complex with these monovalent ions. Impedance results for the interaction between aptamer and thrombin indicated that thrombin interacts more with folded aptamer than with unfolded aptamer. The EQCM technique provided a quantitative analysis of these results. In particular, the present impedance results showed that thrombin participates a folding of aptamer to some extent, and XPS analysis confirmed that thrombin stabilizes and induces the folding of aptamer.  相似文献   

4.
Different assay formats based on the coupling of magnetic beads with electrochemical transduction were compared here for the detection of thrombin by using a thrombin specific aptamer. By using the thrombin-binding aptamer, a direct and an indirect competitive assay for thrombin have been developed by immobilising the aptamer or the protein, respectively. Moreover, another strategy was based on the direct measurement of the enzymatic product of thrombin captured by the immobilised aptamer. All the assays were developed by coupling the electrochemical transduction with the innovative and advantageous use of magnetic beads.

The assays based on the immobilisation of the protein were not successful since no binding was recorded between thrombin and its aptamer. With the direct competitive assay, when the aptamer was immobilised onto the magnetic beads, a detection limit of 430 nM for thrombin was achieved. A lower detection limit for the protein (175 nM) was instead obtained by detecting the product of the enzymatic reaction catalysed by thrombin. All these assays were finally compared with a sandwich assay which reached a detection limit of 0.45 nM of thrombin demonstrating the best analytical performances.

With this comparison the importance of a deep study on the different analytical approaches for thrombin detection to reach the performances of the best assay configuration has been demonstrated.  相似文献   


5.
Aptamers have been utilized as biosensors because they can be readily adapted to sensor platforms and signal transduction schemes through both rational design and selection. One highly generalizable scheme for the generation of the so‐called aptamer beacons involves denaturing the aptamer with antisense oligonucleotides. For example, rational design methods have been utilized to adapt anti‐thrombin aptamers to function as biosensors by hybridizing an antisense oligonucleotide containing a quencher to the aptamer containing a fluorescent label. In the presence of thrombin, the binding equilibrium is shifted, the antisense oligonucleotide dissociates, and the beacon lights up. By changing the affinity of the antisense oligonucleotide for the aptamer beacon, it has proven possible to change the extent of activation of the beacon. More importantly, modulating interactions between the antisense oligonucleotide and the aptamer strongly influences the kinetics of activation. Comparisons across multiple, designed aptamer beacons indicate that there is a strong inverse correlation between the thermodynamics of hybridization and the speed of activation, a finding that should prove to be generally useful in the design of future biosensors. By pre‐organizing the thrombin‐binding quadruplex within the aptamer the speed of response can be greatly increased. By integrating these various interactions, we were ultimately able to design aptamer beacons that were activated by threefold within 1 min of the addition of thrombin. Biotechnol. Bioeng. 2009;103: 1049–1059. © 2009 Wiley Periodicals, Inc.  相似文献   

6.
Zhang J  Chen P  Wu X  Chen J  Xu L  Chen G  Fu F 《Biosensors & bioelectronics》2011,26(5):2645-2650
A novel signal-on junction-probe electrogenerated chemiluminescence (ECL) aptamer biosensor has been developed for the detection of ultratrace thrombin based on a structure-switching ECL-quenching mechanism. The ECL aptamer biosensor comprises two main parts: an ECL substrate and an ECL intensity switch. The ECL substrate was made by modifying the complex of Au nanoparticle and ruthenium (II) tris-bipyridine (Ru(bpy)(3)(2+)-AuNPs) on the surface of gold electrode (GE), and the ECL intensity switch contains three probes designed according to the "junction-probe" strategy. The first probe is capture probe (Cp) which was functionalized with a thiol group at one end and covalently attached to Ru(bpy)(3)(2+)-AuNPs modified GE through S-Au bonding. The second probe is aptamer probe (Ap), which containing 15-base anti-thrombin DNA aptamer. The third one is ferrocene-labeled probe (Fp), which was functionalized with ferrocene tag at one end. We demonstrated that, in the absence of thrombin, Cp, Ap and Fp will hybridize to form a ternary "Y" junction structure and resulted in a quenching of ECL of Ru(bpy)(3)(2+). Whereas, in the presence of thrombin, the Ap prefers to form the G-quadruplex aptamer-thrombin complex and lead to an obvious recovery of ECL of Ru(bpy)(3)(2+), which provided a sensing platform for the detection of thrombin. Using this reusable sensing platform, a simple, rapid and selective signal-on ECL aptamer biosensor for the detection of thrombin with a detection limit of 8.0×10(-15) M has been developed. The success in the present biosensor served as a significant step towards the development of monitoring ultratrace thrombin in clinical detection.  相似文献   

7.
A solid-state electrochemiluminescence (ECL) aptasensor based on target-induced aptamer displacement for highly sensitive detection of thrombin was developed successfully using 4-(dimethylamino)butyric acid (DMBA)@PtNPs labeling as enhancer. Such a special aptasensor included three main parts: ECL substrate, ECL intensity amplification and target-induced aptamer displacement. The ECL substrate was made by modifying the complex of Pt nanoparticles (PtNPs) and tris(2,2-bipyridyl) ruthenium (II) (Ru(bpy)(3)(2+)) (Ru-PtNPs) onto nafion@multi-walled carbon nanotubes (nafion@MWCNTs) modified electrode surface. A complementary thrombin aptamer labeled by DMBA@PtNPs (Aptamer II) acted as the ECL intensity amplification. The thrombin aptamer (TBA) was applied to hybridize with the labeled complementary thrombin aptamer, yielding a duplex complex of TBA-Aptamer II on the electrode surface. The introduction of thrombin triggered the displacement of Aptamer II from the self-assembled duplex into the solution and the association of inert protein thrombin on the electrode surface, decreasing the amount of DMBA@PtNPs and increasing the electron transfer resistance of the aptasensor and thus resulting large decrease in ECL signal. With the synergistic amplification of DMBA and PtNPs to Ru(bpy)(3)(2+) ECL, the aptasensor showed an enlarged ECL intensity change before and after the detection of thrombin. As a result, the change of ECL intensity has a direct relationship with the logarithm of thrombin concentration in the range of 0.001-30 nM. The detection limit of the proposed aptasensor is 0.4 pM. Thus, the approach is expected to open new opportunities for protein diagnostics in clinical as well as bioanalysis in general.  相似文献   

8.
A dominant aptamer loop structure from a library of nearly 100 candidate aptamer sequences developed against immobilized 25‐hydroxyvitamin D3 (calcidiol) was converted into a 5′‐TYE 665 and 3′‐Iowa black‐labelled aptamer beacon. The aptamer beacon exhibited a mild 'lights on' reaction in buffer as a function of increasing concentrations of several vitamin D analogues and metabolites, with a limit of detection of approximately 200 ng/mL, and was not specific for any particular congener. In 10% or 50% human serum, the same aptamer beacon inverted its fluorescence behaviour to become a more intense 'lights off' reaction with an improved limit of detection in the range 4–16 ng/mL. We hypothesized that this drastic change in fluorescence behaviour was due to the presence of creatinine and urea in serum, which might destabilize the quenched beacon, causing an increase in fluorescence followed by decreasing fluorescence as a function of vitamin D concentrations that may bind and quench increasingly greater fractions of the denatured beacons. However, the results of several control experiments in the presence of physiological or greater concentrations of creatinine and urea, alone or combined in buffer, failed to produce the beacon fluorescence inversion. Other possible mechanistic hypotheses are also discussed. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
Novel electrochemical detection system for protein in sandwich manner using the aptamers was developed. Two different aptamers, which recognize different positions of thrombin, were chosen to construct sandwich type sensing system for protein, and one was immobilized onto the gold electrode for capturing thrombin onto the electrode and the other was used for detection. To obtain the signal, the aptamer for detection was labeled with pyrroquinoline quinone glucose dehydrogenase ((PQQ)GDH), and the electrical current, generated from glucose addition after the formation of the complex of thrombin, gold immobilized aptamer and the (PQQ)GDH labeled aptamer on the electrode, was measured. The increase of the electric current generated by (PQQ)GDH was observed in dependent manner of the concentration of thrombin added, and more than 10nM thrombin was detected selectively. The batch type protein sensing system was constructed using the two different aptamers sandwiching thrombin and it showed linear response to the increase of the thrombin concentration in the range of 40-100 nM.  相似文献   

10.
The serine protease coagulation factor thrombin functions primarily in hemostasis, but is also involved in atherosclerosis, thromboembolic disease, cancer and inflammatory disease. Direct measurement of coagulation proteins including thrombin in plasma samples poses a significant challenge because of lack of specific probes and low thrombin concentrations. In addition, high plasma protein concentrations in samples can result in high backgrounds. These challenges were overcome using a bi-cell surface plasmon resonance (SPR) spectrometer with an immobilized thrombin aptamer to measure thrombin in samples passed through a low volume flow cell. For thrombin in Tris-EDTA buffer, the limit of detection (LOD) was 25 nM. Coefficient of variation (CV) for detection of 50 nM was 12.2% and 12.4% for intra and inter-day measurements respectively. This detection was specific for both thrombin aptamer and for thrombin. Using serum samples spiked with thrombin, the LOD was 50 nM with a linear range of detection from 50 nM to 200 nM. However use of serum samples was associated with consistent, low-level background drift. The contributions of nonspecific protein absorption onto the sensor surface and sample flow speed were assessed, and strategies to reduce this background drift were explored. We conclude that the bi-cell SPR platform with an aptamer capture probe can be employed as a highly sensitive real-time, label-free biosensor for the detection of coagulation factors in plasma samples.  相似文献   

11.
A novel electrochemical method for the detection of bioaffinity interactions based on a gold-nanoparticles sensing platform and on the usage of stripping voltammetry technique was developed. The oxidation of gold surface (resulted in gold oxide formation) upon polarization served as a basis for analytical response. As a model, thrombin-thrombin binding aptamer couple was chosen. The aptamer was immobilized on a screen-printed electrode modified with gold-nanoparticles by avidin-biotin technology. Cathodic peak area was found proportional to thrombin quantity specifically adsorbed onto electrode surface. Sigmoid calibration curve as is typical for immunoassay was obtained, with thrombin detection limit of 10(-9)M. Linear range corresponds from 10(-8) to 10(-5)M thrombin concentration or 2 x 10(-14) to 2 x 10(-11)mol/electrode (R=0.996). Binding of thrombin to an aptamer has also been detected using the ferricyanide/ferrocyanide redox couple as electrochemical indicator.  相似文献   

12.
Wang Y  He X  Wang K  Ni X  Su J  Chen Z 《Biosensors & bioelectronics》2011,26(8):3536-3541
A sensitive and specific electrochemical assay for detection of thrombin based on aptamer and ferrocenylhexanethiol loaded silica nanocapsules (FcSH/SiNCs) amplification is described. In the protocol, a double aptamer sandwich structure was formed in the presence of thrombin, in which an aptamer-labeled FcSH/SiNCs for electrochemical detection, and a streptavidin-coated magnetic bead immobilized aptamer for rapid and specific separation of target protein. After separated from the sample mixture under a magnetic field, the sandwich complex was treated with NaOH to release the loaded ferrocenylhexanethiol (FcSH) from the silica nanocapsules (SiNCs). Differential pulse voltammetry (DPV) was employed to detect the released FcSH, which was related to the concentration of the thrombin. The method took advantage of sandwich binding of two affinity aptamers for increased specificity, high payload of FcSH in SiNCs for signal amplification, magnetic beads for fast magnetic separation. The peak current of released FcSH had a good linear relationship with the thrombin concentration in the range of 0.1-5 nmol/L, and the detection limit of thrombin in the method was 0.06 nmol/L. The detection was also specific for thrombin without being affected by other proteins, such as immunoglobulin G, bovine serum albumin, lysozyme and human serum albumin. The method has been used to detect thrombin in human serum albumin with minimum background interference.  相似文献   

13.
Molecular aptamer beacons for real-time protein recognition   总被引:13,自引:0,他引:13  
One of the most pressing problems facing those attempting to understand the regulation of gene expression and translation is the necessity to monitor protein production in a variety of metabolic states. Thus far, there is no easy solution that will either identify or quantitate proteins in real time. Here we introduce a novel protein probe, molecular aptamer beacon (MAB), for real time protein recognition and quantitative analysis. The MAB combines the signal transduction mechanism of molecular beacons and the molecular recognition specificity of aptamers. An MAB based on a thrombin-binding aptamer was prepared as a model to demonstrate the feasibility. Significant fluorescent signal change was observed when MAB was bound to thrombin, which is attributed to a significant conformational change in MAB from a loose random coil to a compact unimolecular quadruplex. The MAB recognizes its target protein with high specificity and high sensitivity (112 picomolar thrombin concentration) in homogeneous solutions. Ratiometric imaging has been conducted with MAB labeled with two fluorophores, which makes it feasible for protein quantitation in living specimen. The unique properties of the MAB will enable the development of a class of protein probes for real time protein tracing in living specimen and for efficient biomedical diagnosis in homogeneous solutions.  相似文献   

14.
Aptamer-based drugs represent an attractive approach in pharmacological therapy. The most studied aptamer, thrombin binding aptamer (TBA), folds into a well-defined quadruplex structure and binds to its target with good specificity and affinity. Modified aptamers with improved biophysical properties could constitute a new class of therapeutic aptamers. In this study we show that the modified thrombin binding aptamer (mTBA), 3′GGT5′-5′TGGTGTGGTTGG3′, which also folds into a quadruplex structure, is more stable than its unmodified counterpart and shows a higher thrombin affinity. The stability of the modified aptamer was investigated using differential scanning calorimetry, and the energetics of mTBA and TBA binding to thrombin was characterized by means of isothermal titration calorimetry (ITC). ITC data revealed that TBA/thrombin and mTBA/thrombin binding stoichiometry is 1:2 for both interactions. Structural models of the two complexes of thrombin with TBA and with mTBA were also obtained and subjected to molecular dynamics simulations in explicit water. Analysis of the models led to an improvement of the understanding of the aptamer-thrombin recognition at a molecular level.  相似文献   

15.
目的:验证适配子G81的纤维蛋白靶向性,评估适配子对凝血系统的影响。方法:以复钙法制备鼠源、人源体外纤维蛋白,将不同浓度Cy5.5标记的适配子溶液与之孵育,置于激光共聚焦显微镜下以固定的参数成像,用ImageJ软件进行相对荧光强度分析;将适配子G81溶液加入血浆中,通过倍比稀释法得到含浓度梯度适配子的血浆,采用SYSMEX CS-5100全自动血凝仪检测PT、APTT、TT,评估适配子G81对凝血功能的影响。结果:激光共聚焦显微镜显示适配子能与纤维蛋白结合,随着加入适配子量的增加其相对荧光强度逐渐增强,表明适配子可与纤维蛋白结合,统计分析提示荧光强度与适配子存在量效关系;人源、鼠源纤维蛋白结合的荧光强度无统计学差异(P0.05)。在抗凝活性检测中,血浆中适配子G81浓度达到200 pmoL/mL时,各浓度统计分析结果均显示P0.05,表明适配子对PT、APTT、TT的测量均没有统计学差异上的影响。结论:适配子G81具有纤维蛋白靶向性,且当加入的适配子剂量低于200 pmol/mL时对内、外源性凝血功能、凝血酶时间均无明显影响。  相似文献   

16.
17.
The occurrence of a G-triplex folding intermediate of thrombin binding aptamer (TBA) has been recently predicted by metadynamics calculations, and experimentally supported by Nuclear Magnetic Resonance (NMR), Circular Dichroism (CD) and Differential Scanning Calorimetry (DSC) data collected on a 3′ end TBA-truncated 11-mer oligonucleotide (11-mer-3′-t-TBA). Here we present the solution structure of 11-mer-3′-t-TBA in the presence of potassium ions. This structure is the first experimental example of a G-triplex folding, where a network of Hoogsteen-like hydrogen bonds stabilizes six guanines to form two G:G:G triad planes. The G-triplex folding of 11-mer-3′-t-TBA is stabilized by the potassium ion and destabilized by increasing the temperature. The superimposition of the experimental structure with that predicted by metadynamics shows a great similarity, with only significant differences involving two loops. These new structural data show that 11-mer-3′-t-TBA assumes a G-triplex DNA conformation as its stable form, reinforcing the idea that G-triplex folding intermediates may occur in vivo in human guanine-rich sequences. NMR and CD screening of eight different constructs obtained by removing from one to four bases at either the 3′ and the 5′ ends show that only the 11-mer-3′-t-TBA yields a relatively stable G-triplex.  相似文献   

18.
A colorimetric sandwich-type assay based on enzyme-linked aptamer assay has been developed for the fast and sensitive detection of as low as 25 fM of thrombin with high linearity. Aptamer-immobilized glass was used to capture the target analyte, whereas a second aptamer, functionalized with horseradish peroxidase (HRP), was employed for the conventional 3,5,3′,5′-tetramethylbenzidine (TMB)-based colorimetric detection. Without the troublesome antibody requirement of the conventional enzyme-linked immunosorbent assay (ELISA), as low as 25 fM of thrombin could be rapidly and reproducibly detected. This assay has superior, or at least equal, recovery and accuracy to that of conventional antibody-based ELISA.  相似文献   

19.
A novel molecular aptamer beacon (MAB) was designed by integrating a single-labeled hairpin-shaped aptamer and graphene oxide (GO). The hairpin-shaped aptamer was constructed with anti-ATP aptamer and another five nucleotides added to the 5'-end of the aptamer which are complementary to nucleotides at the 3'-end of the aptamer to form a hairpin-shaped probe. This newly designed MAB which acts as a low background signal platform was used for the ATP detection based on long-range resonance energy transfer (LrRET). In the absence of ATP, the adsorption of the dye-labeled hairpin-shaped aptamer on GO makes the dyes close proximity to GO surface resulting in high efficiency quenching of fluorescence of the dyes. Therefore, the fluorescence of the designed MAB is completely quenched by GO, and the system shows very low background. Conversely, and very importantly, upon the adding of ATP, the quenched fluorescence is recovered significantly, and ATP can be detected in a wide range of 5-2500μM with a detection limit of 2μM and good selectivity. Moreover, when the GO-based MAB was used in cellular ATP assays, preeminent fluorescence signals were obtained, thus the platform of GO-based MAB could be used to detect ATP in real-world samples.  相似文献   

20.
In the literature, the thrombin binding aptamer GGTTGGTGTGGTTGG is generally taken as a prototype of an intramolecular guanine tetraplex of DNA. Our results, however, show that this notion is not true in aqueous solutions. This conclusion is based on a dependence of the CD spectra on aptamer concentration, migration of the aptamer in polyacrylamide gels, and the Ferguson analysis of the gel migration data. The presented data document that the aptamer forms a bimolecular tetraplex. We furthermore show that only an extension of the aptamer by a sequence containing further guanines, or an elongation of loop regions, causes that its tetraplex folding is intramolecular.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号