首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Dynamic performance characteristics of the liquid metal strain gage   总被引:2,自引:0,他引:2  
Performance characteristics of the liquid metal strain gage (LMSG) were evaluated by both static and dynamic bench testing. Statically, the devices were found to have outputs closely proportional to engineering strains, up to strain levels of 40%. While individual gage factors varied appreciably (up to 50%), each of the gages studied showed excellent reproducibility of behavior. Dynamically, the response to sinusoidal strain inputs was frequency-independent up to 50 Hz, and there was no detectable phase shift. Similarly, the LMSG response to constant-speed displacement inputs was velocity-independent over the range of nominal strain rates from 20 s-1 to 0.02 s-1. The devices proved capable of maintaining stable outputs when held stretched to fixed lengths, even if such tests were performed immediately following stepwise displacement inputs. Thermal artifacts were found to be modest (0.185% apparent strain per degree C), and there was no appreciable sensitivity to non-axial strains. When mounted on an in vitro ligament preparation, the LMSG measured apparent ligament strain similar to that detected by a video dimension analyzer. A protocol by which an implanted LMSG could be used to infer in vivo muscle forces was demonstrated, based on recordings of tendo-Achilles strains developed by a rabbit during slow hopping.  相似文献   

2.
Biological tools allow extensive exploration of muscle physiology and pathology. The progressive appraisal of muscle function, as a result of research carried out to investigate myopathies has been a significant scientific advancement. This progress was followed by the development of biological markers that allow the study of very different situations in vivo. The current tests can be automated with immunochemical machines producing reliable results in a short period of time. Emergency response in trauma or evaluation is thus enhanced.  相似文献   

3.
This paper describes a technique for characterizing strains and stresses induced in vivo in the rat tibia during application of an external four-point bending load. An external load was applied through the muscle and soft tissue with a four-point bending device, to induce strain in a 11 mm section of the right tibiae of ten adult female Sprague-Dawley rats. Induced strains were measured in vivo on the lateral surface of the tibia. Inter-rat difference, leg positioning and strain gage placement were evaluated as sources of variability of applied strains. Beam bending theory was used to predict externally induced in vivo strains. Finite element analysis was used to quantify the magnitude of shear stresses induced by this type of loading. There was a linear relationship between applied load and induced in vivo strains. In vivo strains induced by external loading were linearly correlated (R2 = 0.87) with the strains calculated using beam bending theory. The finite element analysis predicted shear stresses at less than 10% of the longitudinal stresses resulting from four-point bending. Strains predicted along the tibia by finite element analysis and beam bending theory were well-correlated. Inter-rat variability due to tibia size and shape difference was the most important source of variation in induced strain (CV = 21.6%). Leg positioning was less important (CV = 9.5%).  相似文献   

4.
An axial extensometer able to measure global bone strain magnitudes and rates encountered during physiological activity, and suitable for use in vivo in human subjects, is described. The extensometer uses paired capacitive sensors mounted to intraosseus pins and allows measurement of strain due to bending in the plane of the extensometer as well as uniaxial compression or tension. Data are presented for validation of the device against a surface-mounted strain gage in an acrylic specimen under dynamic four-point bending, with square wave and sinusoidal loading inputs up to 1500 mu epsilon and 20 Hz, representative of physiological strain magnitudes and frequencies. Pearson's correlation coefficient (r) between extensometer and strain gage ranged from 0.960 to 0.999. Mean differences between extensometer and strain gage ranged up to 15.3 mu epsilon. Errors in the extensometer output were directly proportional to the degree of bending that occurs in the specimen, however, these errors were predictable and less than 1 mu epsilon for the loading regime studied. The device is capable of tracking strain rates in excess of 90,000 mu epsilon/s.  相似文献   

5.
A quick and easy method by which reliable and accurate liquid metal strain gages (LMSG) can be manufactured for use in measuring large strains within biological tissues has been developed. The circuitry used to power the gages is also simple and allows gage voltages to be recorded without the need for instrumentation amplifiers. An added advantage is that the gage output indicates absolute gage length rather than change in gage length. Lastly, evaluation of these gages error sensitivity has shown them to be acceptable for measurement of strains of magnitudes occurring within many soft tissues.  相似文献   

6.
The phosphoinositide 3-kinase/Akt pathway is thought to be essential for normal insulin action and glucose metabolism in skeletal muscle and has been shown to be dysregulated in insulin resistance. However, the specific roles of and signaling pathways triggered by Akt isoforms have not been fully assessed in muscle in vivo. We overexpressed constitutively active (ca-) Akt-1 or Akt-2 constructs in muscle using in vivo electrotransfer and, after 1 wk, assessed the roles of each isoform on glucose metabolism and fiber growth. We achieved greater than 2.5-fold increases in total Ser473 phosphorylation in muscles expressing ca-Akt-1 and ca-Akt-2, respectively. Both isoforms caused hypertrophy of muscle fibers, consistent with increases in p70S6kinase phosphorylation, and a 60% increase in glycogen accumulation, although only Akt-1 increased glycogen synthase kinase-3beta phosphorylation. Akt-2, but not Akt-1, increased basal glucose uptake (by 33%, P = 0.004) and incorporation into glycogen and lipids, suggesting a specific effect on glucose transport. Consistent with this, short hairpin RNA-mediated silencing of Akt-2 caused reductions in glycogen storage and glucose uptake. Consistent with Akt-mediated insulin receptor substrate 1 (IRS-1) degradation, we observed approximately 30% reductions in IRS-1 protein in muscle overexpressing ca-Akt-1 or ca-Akt-2. Despite this, we observed no decrease in insulin-stimulated glucose uptake. Furthermore, a 68% reduction in IRS-1 levels induced using short hairpin RNAs targeting IRS-1 also did not affect glucose disposal after a glucose load. These data indicate distinct roles for Akt-1 and Akt-2 in muscle glucose metabolism and that moderate reductions in IRS-1 expression do not result in the development of insulin resistance in skeletal muscle in vivo.  相似文献   

7.
Single element foil strain gages were bonded to mandibular cortical bone in eight specimens of Galago crassicaudatus. The gage was bonded below the Pm4 or M2 adjacent to the lower border of the mandible. The bonded strain gage was connected to form one arm of a Wheatstone bridge. Following recovery from the general anesthetic, the restrained Galago bit either a piece of wood, a food object, or a bite force transducer. During these biting episodes, mandibular bone strain deformed the strain gage and the resulting change in electrical resistance of the gage caused voltage changes across the Wheatstone bridge. These changes, directly proportional to the amount of bone strain along the gage site, were recovered by a strip chart recorder. Bone strain was measured on both the working and balancing sides of the jaws. Maximum values of bone strain and bite force were 435 microstrain (compression) and 8.2 kilograms respectively. During bending of the mandible, the correlation between bone strain (tension or compression) and bite force ranged from -0.893 (tension) to 0.997 (compression). The experiments reported here demonstrate that only a small percentage of the Galago bite force is due to balancing side muscle force during isometric unilateral molar biting. In addition, these experiments demonstrate that the Galago mandible is bent in a predictable manner during biting. The amount of apparent mandibular bone strain is dependent on (1) the magnitude of the bite force and (2) the position of the bite point.  相似文献   

8.
The forelimb digital flexors of the horse display remarkable diversity in muscle architecture despite each muscle-tendon unit having a similar mechanical advantage across the fetlock joint. We focus on two distinct muscles of the digital flexor system: short compartment deep digital flexor (DDF(sc)) and the superficial digital flexor (SDF). The objectives were to investigate force-length behavior and work performance of these two muscles in vivo during locomotion, and to determine how muscle architecture contributes to in vivo function in this system. We directly recorded muscle force (via tendon strain gauges) and muscle fascicle length (via sonomicrometry crystals) as horses walked (1.7 m s(-1)), trotted (4.1 m s(-1)) and cantered (7.0 m s(-1)) on a motorized treadmill. Over the range of gaits and speeds, DDF(sc) fascicles shortened while producing relatively low force, generating modest positive net work. In contrast, SDF fascicles initially shortened, then lengthened while producing high force, resulting in substantial negative net work. These findings suggest the long fibered, unipennate DDF(sc) supplements mechanical work during running, whereas the short fibered, multipennate SDF is specialized for economical high force and enhanced elastic energy storage. Apparent in vivo functions match well with the distinct architectural features of each muscle.  相似文献   

9.
In vivo electroporation is increasingly being used to deliver small molecules as well as DNA to tissues. The aim of this study was to quantitatively investigate in vivo electroporation of skeletal muscle, and to determine the threshold for permeabilization. We designed a quantitative method to study in vivo electroporation, by measuring uptake of (51)Cr-EDTA. As electrode configuration influences electric field (E-field) distribution, we developed a method to calculate this. Electroporation of mouse muscle tissue was investigated using either external plate electrodes or internal needle electrodes placed 4 mm apart, and eight pulses of 99 micros duration at a frequency of 1 Hz. The applied voltage to electrode distance ratio was varied from 0 to 2.0 kV/cm. We found that: (1) the threshold for permeabilization of skeletal muscle tissue using short duration pulses was at an applied voltage to electrode distance ratio of 0.53 kV/cm (+/-0.03 kV/cm), corresponding to an E-field of 0.45 kV/cm; (2) there were two phases in the uptake of (51)Cr-EDTA, the first indicating increasing permeabilization and the second indicating beginning irreversible membrane damage; and (3) the calculated E-field distribution was more homogeneous for plate than for needle electrodes, which was reflected in the experimental results.  相似文献   

10.
Assembly of smooth muscle myosin into side-polar filaments   总被引:9,自引:5,他引:4       下载免费PDF全文
The in vitro assembly of myosin purified from calf aorta muscle has been studied by electron microscopy. Two types of filament are formed: short bipolar filament similar to those formed from skeletal muscle myosin, and longer "side-polar" filaments having cross bridges with a single polarity along the entire length of one side and the opposite polarity along the other side. Unlike the case with skeletal myosin filaments, antiparallel interactions between myosin molecules occur along the whole length of side-polar filaments. The side-polar structure may be related to the in vivo form of myosin in vertebrate smooth muscle.  相似文献   

11.
It has been shown that airway smooth muscle in vitro is able to maintain active force over a large length range by adaptation in the absence of periodic stimulations at 4 degrees C (Wang L, Paré PD, and Seow CY. J Appl Physiol 90: 734-740, 2001). In this study, we show that such adaptation also takes place at body temperature and that long-term adaptation results in irreversible functional change in the muscle that could lead to airway hyperresponsiveness. Rabbit tracheal muscle explants were passively maintained at shortened and in situ length for 3 and 7-8 days in culture media; the length-tension relationship was then examined. The length associated with maximal force generation decreased by 10.5 +/- 3.8% (SE) after 3 days and 37.7 +/- 8.5% after 7 or 8 days of passive shortening. At day 3, the left shift in the length-tension curve due to adaptation at short lengths was reversible by readapting the muscle at a longer length. The shift was, however, not completely reversible after 7 days. The results suggest that long-term adaptation of airway smooth muscle could lead to increased muscle stiffness and force-generating ability at short lengths. Under in vivo condition, this could translate into resistance to stretch-induced relaxation and excessive airway narrowing.  相似文献   

12.
13.
Electrical stimulation of the sciatic nerve of the anaesthetized rat in vivo led to a time-dependent translocation of protein kinase C from the muscle cytosol to the particulate fraction. Maximum activity of protein kinase C in the particulate fraction occurred after 2 min of intermittent short tetanic contractions of the gastrocnemius-plantaris-soleus muscle group and coincided with the loss of activity from the cytosol. Translocation of protein kinase C may imply a role for this kinase in contraction-initiated changes in muscle metabolism.  相似文献   

14.
Recent work has employed video and sonometric analysis combined with hydrodynamic modeling to estimate power output by the feeding musculature of largemouth bass in feeding trials. The result was an estimate of approximately 69 W kg(-1) of power by the epaxial muscle during maximal feeding strikes. The present study employed in vitro measurements of force, work and power output by fast-twitch epaxial muscle bundles stimulated under activation conditions measured in vivo to evaluate the power output results of the feeding experiments. Isolated muscle bundles from the epaxial muscle, the sternohyoideus and the lateral red or slow-twitch muscle were tied into a muscle mechanics apparatus, and contractile properties during tetanic contractions and maximum shortening velocity (Vmax) were determined. For the epaxial muscles, work and power output during feeding events was determined by employing mean stimulation conditions derived from a select set of maximal feeding trials: 17% muscle shortening at 3.6 muscle lengths/s, with activation occurring 5 ms before the onset of shortening. Epaxial and sternohyoideus muscle displayed similar contractile properties, and both were considerably faster (Vmax approximately 11-13 ML s(-1)) than red muscle (Vmax approximately 5 ML s(-1)). Epaxial muscle stimulated under in vivo activation conditions generated approximately 60 W kg(-1) with a 17% strain and approximately 86 W kg(-1) with a 12% strain. These values are close to those estimated by hydrodynamic modeling. The short lag time (5 ms) between muscle activation and muscle shortening is apparently a limiting parameter during feeding strikes, with maximum power found at an offset of 15-20 ms. Further, feeding strikes employing a faster shortening velocity generated significantly higher power output. Power production during feeding strikes appears to be limited by the need for fast onset of movement and the hydrodynamic resistance to buccal expansion.  相似文献   

15.
Residual force enhancement (RFE) is a term describing the observation that muscle tension during a contraction that includes a stretch and hold remains above that during an isometric contraction at the hold length. RFE has been observed during in vitro and in vivo experiments, but results involving voluntary contractions are mixed, particularly with respect to large muscles. The purpose of this study was to determine if RFE can be observed in large muscles such as knee extensors and flexors at joint configurations corresponding to the ascending and descending limbs of the muscle force-length curve. Two groups of twenty participants (ten males and ten females per group) performed maximum voluntary contractions on a Biodex machine in purely isometric conditions and in isometric conditions immediately following eccentric stretch. Knee extension trials were performed at 40° (short muscles) and 100° (long muscles) flexion from full extension (0°), and knee flexion trials were performed at 70° (short muscles) and 10° (long muscles) flexion. Stretch-isometric trials terminated at these angles following 30° of eccentric motion at 30°/s. Statistically-significant RFE was observed for both tasks at long-muscle joint configurations, but was not observed for either task at short-muscle joint configurations. Passive torque enhancement was also observed following muscle relaxation at long-muscle joint configurations for both tasks, but for only knee flexion at short-muscle joint configurations. These results reinforce for voluntary contractions of large muscles the RFE behavior observed in smaller muscles, and provide further evidence that RFE occurs primarily on the descending limb of the muscle force-length curve.  相似文献   

16.
17.
A method is described to estimate the line of action of muscles in the three-dimensional space from serial images of parallel muscle sections obtained in vivo by means of CT or MRI scanning. The external shape of a muscle, reconstructed from the series of parallel sections, is mathematically divided into a series of imaginary slices directed arbitrarily in the three-dimensional space. The line of action is estimated initially as a regression line through the centroids of these mathematical slices. A new series of mathematical slices is constructed perpendicular to the regression line and a new estimate of the line of action is obtained from their centroids. This procedure is repeated until the estimated line of action is perpendicular to the mathematical slices; it can then be considered as a reliable estimate of the line of action. The accuracy of the method has been tested for various reconstruction parameters and muscle shapes. The results of these tests show that the accuracy is relatively independent of the direction in which the sectional images have been made and that, except for relatively short and thick muscles, the estimated lines of action deviated less than about 2 degrees from the theoretical one. The presented method is a relatively simple mathematical technique which can be used easily for muscles reconstructed in vivo from routinely obtained sectional MRI or CT images.  相似文献   

18.
Previous studies have reported that oxidizing free radical species are generated during exercise, and there has been considerable interest in the potential effects of these on exercising tissues. We hypothesized that contracting skeletal muscle was a major source of oxidizing free radical species and that untrained skeletal muscle would adapt to the oxidative stress of a single short period of contractile activity by upregulation of the activity of cytoprotective proteins in the absence of overt cellular damage. Fifteen minutes of aerobic contractile activity was found to induce a rapid release of superoxide anions from mouse skeletal muscle in vivo, and studies with contracting cultured skeletal muscle myotubes confirmed that this was due to release from myocytes rather than other cell types present within muscle tissue in vivo. This increased oxidant production caused a rapid, transient reduction in muscle protein thiol content, followed by increases in the activities of superoxide dismutase and catalase and in content of heat shock proteins. These changes occurred in the absence of overt damage to the muscle cells.  相似文献   

19.
Muscles behave as elastic springs during the initial strain phase, indicated as short range stiffness (SRS). Beyond a certain amount of strain the muscle demonstrates a more viscous behavior. The strain at which the muscle transits from elastic- to viscous-like behavior is called the elastic limit and is believed to be the result of breakage of cross-bridges between the contractile filaments. The aim of this study was to test whether the elastic limit, measured in vivo at the wrist joint, depended on the speed of lengthening. Brief extension rotations were imposed to the wrist joint (n=8) at four different speeds and at three different levels of voluntary torque using a servo controlled electrical motor. Using a recently published identification scheme, we quantified the elastic limit from measured joint angle and torque. The results showed that the elastic limit significantly increased with speed in a linear way, indicating to a constant time of approximately 30 ms before cross-bridges break. The implications for movement control of the joint are discussed.  相似文献   

20.
The passive properties of skeletal muscle are often overlooked in muscle studies, yet they play a key role in tissue function in vivo. Studies analyzing and modeling muscle passive properties, while not uncommon, have never investigated the role of fluid content within the tissue. Additionally, intramuscular pressure (IMP) has been shown to correlate with muscle force in vivo and could be used to predict muscle force in the clinic. In this study, a novel model of skeletal muscle was developed and validated to predict both muscle stress and IMP under passive conditions for the New Zealand White Rabbit tibialis anterior. This model is the first to include fluid content within the tissue and uses whole muscle geometry. A nonlinear optimization scheme was highly effective at fitting model stress output to experimental stress data (normalized mean square error or NMSE fit value of 0.993) and validation showed very good agreement to experimental data (NMSE fit values of 0.955 and 0.860 for IMP and stress, respectively). While future work to include muscle activation would broaden the physiological application of this model, the passive implementation could be used to guide surgeries where passive muscle is stretched.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号