 共查询到20条相似文献,搜索用时 109 毫秒
1.
Integral membrane proteins are notoriously difficult to identify and analyze by mass spectrometry because of their low abundance and limited number of trypsin cleavage sites. Our strategy to address this problem is based on a novel technology for MALDI-MS peptide sample preparation that increases the success rate of membrane protein identification by increasing the sensitivity of the MALDI-TOF system. For this, we used sample plates with predeposited matrix spots of CHCA crystals prepared by vacuum sublimation onto an extremely low wettable (ultraphobic) surface. In experiments using standard peptides, an up to 10-fold gain of sensitivity was found for on-chip preparations compared with classical dried-droplet preparations on a steel target. In order to assess the performance of the chips with membrane proteins, three model proteins (bacteriorhodopsin, subunit IV(a) of ATP synthase, and the cp47 subunit from photosystem II) were analyzed. To mimic realistic analysis conditions, purified proteins were separated by SDS-PAGE and digested with trypsin. The digest MALDI samples were prepared either by dried-droplet technique on steel plates using CHCA as matrix, or applied directly onto the matrix spots of the chip surface. Significantly higher signal-to-noise ratios were observed for all of the spectra resulting from on-chip preparations of different peptides.In a second series of experiments, the membrane proteome of Rhodococcus jostii RHA1 was investigated by AIEC/SDS-PAGE in combination with MALDI-TOF MS/MS. As in the first experiments, Coomassie-stained SDS-PAGE bands were digested and the two different preparation methods were compared. For preparations on the Mass·Spec·Turbo Chip, 43 of 60 proteins were identified, whereas only 30 proteins were reliably identified after classical sample preparation. Comparison of the obtained Mascot scores, which reflect the confidence level of the protein identifications, revealed that for 70% of the identified proteins, higher scores were obtained by on-chip sample preparation. Typically, this gain was a consequence of higher sequence coverage due to increased sensitivity.  相似文献   

2.
High-resolution capillary electrophoresis has been coupled to MALDI-TOF and TOF/TOF MS through off-line vacuum deposition onto standard stainless steel MALDI targets. This off-line approach allowed the decoupling of the separation from the MS analysis, thus allowing each to be independently optimized in terms of time. Using BSA tryptic digest as a model sample, the deposited streaks, roughly 100-microm wide, were first analyzed in the MS mode, consuming only a fraction of the sample. After data analysis, segments of the deposited trace, containing unidentified peptides, as well as several species chosen for sequence confirmation, were reanalyzed in the MS/MS mode using MALDI-TOF/TOF MS. Additionally, it is shown that the shot-to-shot reproducibility of the vacuum-deposited trace (5% RSD) is 1 order of magnitude lower than that found for the standard dried droplet method. Moreover, a linear dependence of signal intensities (relative to an internal standard) over 3 orders of magnitude was found for a peptide sample with concentrations ranging from 1 to 1000 nM. This paper demonstrates the potential of off-line coupling of high-resolution separations to MALDI-MS and MALDI-MS/MS using vacuum deposition for the analysis of complex peptide mixtures from protein digests.  相似文献   

3.
Analysis and characterization of membrane proteins and hydrophobic peptides by matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is a considerable challenge because of their lower ionization efficiency. Detergents are used to solubilize hydrophobic peptides and proteins. However, in MALDI-MS, the presence of detergents can cause considerable loss of signal intensity. The extent of interference depends on the matrix/sample preparation method and experimental conditions. In the present study, we have analyzed the MALDI response of multiple fatty acylated peptides in the presence of the matrices alpha-cyano-4-hydroxy cinnamic acid (HCCA) and 2,5-dihydroxy benzoic acid (DHB). The effect of adding the nonionic detergent n-octylglucoside (OG) was also examined. The presence of OG facilitated detection of tetrapalmitoylated peptide, particularly when HCCA was used as the matrix. When DHB was used as the matrix, good signal intensity was observed in the absence of OG. Lower laser pulse rate in the linear mode of analysis resulted in good signal intensity for the tetrapalmitoylated peptide. Conditions for obtaining good signal intensities for dipalmitoylated and N-myristoyl peptides with both HCCA and DHB as matrices were also investigated.  相似文献   

4.

Background

We developed a new version of the open source software package Peptrix that can yet compare large numbers of Orbitrap? LC-MS data. The peptide profiling results for Peptrix on MS1 spectra were compared with those obtained from a small selection of open source and commercial software packages: msInspect, Sieve? and Progenesis?. The properties compared in these packages were speed, total number of detected masses, redundancy of masses, reproducibility in numbers and CV of intensity, overlap of masses, and differences in peptide peak intensities. Reproducibility measurements were taken for the different MS1 software applications by measuring in triplicate a complex peptide mixture of immunoglobulin on the Orbitrap? mass spectrometer. Values of peptide masses detected from the high intensity peaks of the MS1 spectra by peptide profiling were verified with values of the MS2 fragmented and sequenced masses that resulted in protein identifications with a significant score.

Findings

Peptrix finds about the same number of peptide features as the other packages, but peptide masses are in some cases approximately 5 to 10 times less redundant present in the peptide profile matrix. The Peptrix profile matrix displays the largest overlap when comparing the number of masses in a pair between two software applications. The overlap of peptide masses between software packages of low intensity peaks in the spectra is remarkably low with about 50% of the detected masses in the individual packages. Peptrix does not differ from the other packages in detecting 96% of the masses that relate to highly abundant sequenced proteins. MS1 peak intensities vary between the applications in a non linear way as they are not processed using the same method.

Conclusions

Peptrix is capable of peptide profiling using Orbitrap? files and finding differential expressed peptides in body fluid and tissue samples. The number of peptide masses detected in Orbitrap? files can be increased by using more MS1 peptide profiling applications, including Peptrix, since it appears from the comparison of Peptrix with the other applications that all software packages have likely a high false negative rate of low intensity peptide peaks (missing peptides).  相似文献   

5.
This study addressed the question of which properties in MALDI-TOF spectra are relevant to the task of identifying mass and abundance of a peptide species in human serum. Data of this type are common to biomarker studies, but significant within- and between-spectrum variabilities make quantifying biologically induced features difficult. We investigated this signal content and quantified the existence, or lack, of peptide-induced signal (as manifest in a multiresolution decomposition) by generating spectra from human serum in which the abundance of peptides of specific masses is controlled by a sequence of dilutions. The intensities of the corresponding features were directly proportional to peptide concentration. The primary goal was to exhibit some quantifiable properties of raw spectra from this application of MALDI-TOF mass spectrometry. Although no recommendations are given regarding the best method for processing these data, the results confirm the utility of a simple method, based on wavelets, for defining and quantifying features related to low abundance peptide species in a heterogeneous set of complex spectra. Estimates on lower limits of detectable peptide abundance (in the 20-nmol range) and on the number of features present in a spectrum are made possible by the controlled experimental design, the use of a large external reference data set, and dependence on relatively few modeling assumptions.  相似文献   

6.
Human follicular fluid (HFF) has been suggested to influence oocyte development potential, and some of HFF proteins may be potential markers for oocyte maturation during follicular development. Using matrix-assisted laser desorption /ionization-time of flight mass spectrometry (MALDI-TOF MS), the presence of specific peptide peaks in HFF which could represent the follicle development potential was evaluated. HFF from different developmental stages were first digested and the resultant peptide mixtures were directly analyzed by MALDI-TOF MS. It was shown that the frequencies of specific peaks demonstrated higher reproducibility than peak intensities after multiple measurements (>or=6 times) per sample. Using this approach, a reliable peak list for each different sample could be generated by combining the information from multiple measurements. By comparing the peak lists from different samples at different growth stages, we found that 5 specific peaks appeared in the 100% frequency category of 6 replicates in all the HFF samples containing mature oocyte. Similarly, such 25 peptide peaks were also identified for HFF containing immature oocyte. These specific peaks could be used to distinguish HFF from different stages as biomarkers related to follicle development and maturation. After searching the protein database, some proteins that are known to be involved in the development and maturation of oocyte were identified, such as apolipoprotein A-I, collagen type IV, integrin, et al. Identification of such proteins in our experiment further proved that the direct analysis of tryptic digests could be of practical value.  相似文献   

7.
Peptidome analysis has received increasing attention in recent years. Cancer diagnosis by serum peptidome has also been reported by peptides' profiling for discovery of peptide biomarkers. Tissue, which may have a higher biomarker concentration than blood, has not been investigated extensively by means of peptidome analysis. Here, a method for the peptidome analysis of mouse liver was developed by the combination of size exclusion chromatography (SEC) prefractionation with nano-liquid chromatography-tamdem mass spectrometry (nanoLC-MS/MS) analysis. The extracted peptides from mouse liver were separated according to their molecular weight using a size exclusion column. MALDI-TOF MS was used to characterize the molecular weight distribution of the peptides in fractions eluted from the SEC column. The low molecular weight (LMW) (MW < 3000 Da) peptides in the collected fractions were directly analyzed by LC-MS/MS which resulted in the identification of 1181 unique peptides (from 371 proteins). The high molecular weight (HMW) (MW > 3000 Da) peptides in the early two fractions from the SEC column were first digested with trypsin, and the resulted digests were then analyzed by LC-MS/MS, which led to the identification of 123 and 127 progenitor proteins of the HMW peptides in fractions 1 and 2, respectively. Analysis of the peptides' cleavage sites showed that the peptides are cleaved in regulation, which may reflect the protease activity and distribution in body, and also represent the biological state of the tissue and provide a fresh source for biomarker discovery.  相似文献   

8.
The identification of peptides and proteins from fragmentation mass spectra is a very common approach in the field of proteomics. Contemporary high-throughput peptide identification pipelines can quickly produce large quantities of MS/MS data that contain valuable knowledge about the actual physicochemical processes involved in the peptide fragmentation process, which can be extracted through extensive data mining studies. As these studies attempt to exploit the intensity information contained in the MS/MS spectra, a critical step required for a meaningful comparison of this information between MS/MS spectra is peak intensity normalization. We here describe a procedure for quantifying the efficiency of different published normalization methods in terms of the quartile coefficient of dispersion (qcod) statistic. The quartile coefficient of dispersion is applied to measure the dispersion of the peak intensities between redundant MS/MS spectra, allowing the quantification of the differences in computed peak intensity reproducibility between the different normalization methods. We demonstrate that our results are independent of the data set used in the evaluation procedure, allowing us to provide generic guidance on the choice of normalization method to apply in a certain MS/MS pipeline application.  相似文献   

9.
Quantitative LC-MS/MS assays were designed for tryptic peptides representing 53 high and medium abundance proteins in human plasma using a multiplexed multiple reaction monitoring (MRM) approach. Of these, 47 produced acceptable quantitative data, demonstrating within-run coefficients of variation (CVs) (n = 10) of 2-22% (78% of assays had CV <10%). A number of peptides gave CVs in the range 2-7% in five experiments (10 replicate runs each) continuously measuring 137 MRMs, demonstrating the precision achievable in complex digests. Depletion of six high abundance proteins by immunosubtraction significantly improved CVs compared with whole plasma, but analytes could be detected in both sample types. Replicate digest and depletion/digest runs yielded correlation coefficients (R(2)) of 0.995 and 0.989, respectively. Absolute analyte specificity for each peptide was demonstrated using MRM-triggered MS/MS scans. Reliable detection of L-selectin (measured at 0.67 microg/ml) indicates that proteins down to the microg/ml level can be quantitated in plasma with minimal sample preparation, yielding a dynamic range of 4.5 orders of magnitude in a single experiment. Peptide MRM measurements in plasma digests thus provide a rapid and specific assay platform for biomarker validation, one that can be extended to lower abundance proteins by enrichment of specific target peptides (stable isotope standards and capture by anti-peptide antibodies (SISCAPA)).  相似文献   

10.
In this paper, we report MALDI-TOF ms analysis of 2-nitrobenzenesulfenyl (NBS) labeled peptides with the powerful aid of an LC-automatic spotting system. using this approach we analyzed mammalian sera (rat and mouse) as biological samples to demonstrate performance. The labeling was carried out using a binary set of 2-nitrobenzenesulfenyl chloride (heavy and light), which modified tryptophan residues in sample proteins. Approximately 1600 doublet peaks were detected in the mass spectrum, some of which had more than threefold differences in their intensities. systematic separation/spotting followed by mass analysis of the NBS-labeled peptides derived from biological samples is described for the first time. This method has proved to be an effective application of NBS-labeled peptides and can be a powerful technique for quantitative analysis of proteins expressed in biological systems.  相似文献   

11.
Though many software packages have been developed to perform label-free quantification of proteins in complex biological samples using peptide intensities generated by LC-MS/MS, two critical issues are generally ignored in this field: (i) peptides have multiple elution patterns across runs in an experiment, and (ii) many peptides cannot be used for protein quantification. To address these two key issues, we have developed a novel alignment method to enable accurate peptide peak retention time determination and multiple filters to eliminate unqualified peptides for protein quantification. Repeatability and linearity have been tested using six very different samples, i.e., standard peptides, kidney tissue lysates, HT29-MTX cell lysates, depleted human serum, human serum albumin-bound proteins, and standard proteins spiked in kidney tissue lysates. At least 90.8% of the proteins (up to 1,390) had CVs ≤ 30% across 10 technical replicates, and at least 93.6% (up to 2,013) had R(2) ≥ 0.9500 across 7 concentrations. Identical amounts of standard protein spiked in complex biological samples achieved a CV of 8.6% across eight injections of two groups. Further assessment was made by comparing mass spectrometric results to immunodetection, and consistent results were obtained. The new approach has novel and specific features enabling accurate label-free quantification.  相似文献   

12.
Protein cleavage-isotope dilution mass spectrometry (PC-IDMS) can be used to quantify proteins, with an isotope-labeled analogue of the peptide fragment used as an internal standard. Here, we investigate use of a standard LC-MS/MS platform for quantifying a model biomarker directly from serum by this technique. We synthesized a peptide (IVGGWECEK) identical to the N-terminal tryptic fragment of PSA but with each glycine containing two 13C atoms and one 15N atom. PSA-free human serum was denatured with urea followed by the introduction of PSA standard and the stable isotope labeled internal standard peptide. The sample was then proteolyzed with trypsin and subjected to quantification using LC-MS/ MS on a triple quadrupole mass spectrometer. A linear least squares calibration curve made from five different concentrations of PSA added to serum and digested (each made in triplicate and randomly injected three times) had a mean slope of 0.973 (SE = 0.023), intercept of -0.003 (SE = 0.022), and R2 of 0.971. Recovery of calibrators ranged from 70 to 85% with a mean run-to-run CV of 13% and a mean within-run CV of 5.7%. PC-IDMS is a promising technique for quantifying proteins covering a broad range of applications from standardizing immunoassays to monitoring post-translational modifications to quantifying newly discovered biomarkers prior to the development and implementation of an immunoassay, just to name a few. Issues surrounding the application of PC-IDMS for the absolute quantification of proteins include selection of a proteolytic fragment for quantification that can be cleaved and isolated reproducibly over a broad dynamic range, stable isotope labeled synthetic peptide standards that give consistent results, and LC-MS/MS methods that provide adequate sensitivity and reproducibility without creating impractical analysis times. The results presented here show that absolute quantification can be performed on the model biomarker PSA introduced into denatured serum when analyzed by LC-MS/MS. However, concerns still exist regarding sensitivity compared to existing immunoassays as well as the reproducibility of PC-IDMS performed in different matrixes.  相似文献   

13.
We designed a new cross‐linker bearing a CHCA moiety. The use of the CHCA‐tagged cross‐linker JMV 3378 in conjunction with a neutral MALDI matrix α‐cyano‐4‐hydroxycinnamic methyl ester enabled specific signal enhancement in MALDI‐TOF MS of cross‐link containing peptides. Discrimination between modified and non‐modified peptides can be achieved by comparison of two spectra, one using CHCA and the other using the α‐cyano‐4‐hydroxycinnamic methyl ester matrix. The methodology was validated using cytochrome c and apo‐myoglobine as model proteins.  相似文献   

14.
There is a great desire to relate the patterns of endogenous peptides in blood to human disease and drug response. The best practices for the preparation of blood fluids for analysis are not clear and also relatively few of the peptides in blood have been identified by tandem mass spectrometry. We compared a number of sample preparation methods to extract endogenous peptides including C18 reversed phase, precipitation, and ultrafiltration. We examined the results of these sample preparation methods by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) and liquid chromatography-tandem mass spectrometry (MS/MS) using MALDI-TOF/TOF and electrospray ionization-ion trap. Peptides from solid-phase extraction with C18 in the range of hundreds of femtomoles per spot were detected from the equivalent of 1 μL of serum by MALDI-TOF. We observed endogenous serum peptides from fibrinogen α- and β-chain, complement C3, α-2-HS-glycoprotein, albumin, serine (or cysteine) proteinase inhibitor, factor VIII, plasminogen, immunoglobulin, and other abundant blood proteins. However, we also recorded significant MS/MS spectra from tumor necrosis factor-α-, major histocompatibility complex-, and angiotensin-related peptides, as well as peptides from collagens and other low-abundance proteins. Amino acid substitutions were detected and a phosphorylated peptide was also observed. This is the first time the endogenous peptides of fetal serum have been examined by MS and where peptides from low-abundance proteins, phosphopeptides, and amino acid substitutions were detected.  相似文献   

15.
16.
Separation and identification of hydrophobic membrane proteins is a major challenge in proteomics. Identification of such sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE)-separated proteins by peptide mass fingerprinting (PMF) via matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) is frequently hampered by the insufficient amount of peptides being generated and their low signal intensity. Using the seven helical transmembrane-spanning proton pump bacteriorhodopsin as model protein, we demonstrate here that SDS removal from hydrophobic proteins by ion-pair extraction prior to in-gel tryptic proteolysis leads to a tenfold higher sensitivity in mass spectrometric identification via PMF, with respect to initial protein load on SDS-PAGE. Furthermore, parallel sequencing of the generated peptides by electrospray ionization-mass spectrometry (ESI-MS) and tandem mass spectrometry (MS/MS) was possible without further sample cleanup. We also show identification of other membrane proteins by this protocol, as proof of general applicability.  相似文献   

17.
18.
A matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)-based kinase assay using a peptide substrate tagged with a biotinyl group has been developed. The peptide moiety was designed to serve as an efficient substrate for calcium/calmodulin-dependent protein kinase II, based on the in vivo phosphorylation site of phosrestin I, a Drosophila homolog of arrestin. In the assay, the quantitative relationship was determined from the ratio of the peak areas between the two peaks respectively representing the unphosphorylated and the phosphorylated substrate. Attempts to assay phosphorylated peptides directly from the reaction mixture, gave inaccurate results because of the high noise level caused by the presence of salts and detergents. In contrast, after purifying the substrate peptides with the biotin affinity tag using streptavidin-coated magnetic beads, peak areas accurately represented the ratio between the unphosphorylated and phosphorylated peptide. By changing the substrate peptide to a peptide sequence that serves as a kinase substrate, it is expected that an efficient non-radioactive protein kinase assay using MALDI-TOF MS can be developed for any type of protein kinase. We call this technique "Affinity-Tagged Phosphorylation Assay by MALDI-TOF MS (ATPA-MALDI)." ATPA-MALDI should serve as a quick and efficient non-radioactive protein kinase assay by MALDI-TOF MS.  相似文献   

19.
Despite the high sensitivity and relatively high tolerance for contaminants of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) there is often a need to purify and concentrate the sample solution, especially after in-gel digestion of proteins separated by two-dimensional gel electrophoresis (2-DE). A silicon microextraction chip (SMEC) for sample clean-up and trace enrichment of peptides was manufactured and investigated. The microchip structure was used to trap reversed-phase chromatography media (POROS R2 beads) that facilitates sample purification/enrichment of contaminated and dilute samples prior to the MALDI-TOF MS analysis. The validity of the SMEC sample preparation technique was successfully investigated by performing analysis on a 10 nM peptide mixture containing 2 m urea in 0.1 m phosphate-buffered saline with MALDI-TOF MS. It is demonstrated that the microchip sample clean-up and enrichment of peptides can facilitate identification of proteins from 2-DE separations. The microchip structure was also used to trap beads immobilized with trypsin, thereby effectively becoming a microreactor for enzymatic digestion of proteins. This microreactor was used to generate a peptide map from a 100 nM bovine serum albumin sample.  相似文献   

20.
Direct matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis of human serum yielded ion signals from only a fraction of the total number of peptides and proteins expected to be in the sample. We increased the number of peptide and protein ion signals observed in the MALDI-TOF mass spectra analysis of human serum by using a prefractionation protocol based on liquid phase isoelectric focusing electrophoresis. This pre-fractionation technique facilitated the MALDI-TOF MS detection of as many as 262 different peptide and protein ion signals from human serum. The results obtained from three replicate fractionation experiments on the same serum sample indicated that 148 different peptide and protein ion signals were reproducibly detected using our isoelectric focusing and MALDI-TOF MS protocol.  相似文献   