 共查询到20条相似文献,搜索用时 31 毫秒
1.
Semiconductor detectors, such as Cadmium Zinc Telluride (CZT), offer improved energy resolution (ER) and potentially improved tumor contrast in breast imaging. We evaluated the effect of changes in ER on tumor contrast. Studies were performed on a prototype CZT detector, a commercial CZT-based system, a multicrystal CsI system and a conventional NaI system. The same low energy high resolution collimator was used on each system and the same total counts (250 kcts) were acquired in each image. CZ-Tmodules in a detector can exhibit different ERs. We imaged a breast phantom containing 4 tumors (diameters 4.9, 7.2, 7.2, and 9.8 mm) over individual CZT modules with intrinsic ers of 5.8–17.5%. Tumor to background ratio was 6.2:1 and tumors were placed 1 and 4 cm deep in the 6-cm thick breast phantom. A standard ±10% energy window and narrower energy windows (−5%/+10% and −7%/ +10%) were used. Tumor contrast was determined by maximum tumor intensity divided by mean background intensity. Tumor contrast was not significantly affected by differences in ER between CZT modules. Tumor contrast improved by 2–10% with a narrow energy window. At the same ER, the CZT systems yielded slightly better contrast than the CsI system. All pixilated systems performed better than the NaI system. Scatter in the breast was found to be low and accounts for only ∼11% of counts in a ±10% energy window for a 6 cm- thick breast. No strong relationship was observed between ER and tumor detectability, which may be due to low scatter in the breast. Detector element size in pixilated systems appears to be more important than ER in determining tumor contrast.  相似文献   

2.
High resolution positron emission mammography (PEM) can address the current clinical needs of breast cancer patients and the requirements for future translational work. Combining the quantitative capabilities of positron emission tomography (PET) with millimeter resolution, PEM can image the earliest in situ forms of breast cancer as well as putative cancer precursor lesions (e.g., atypical ductal hyperplasia) whose behavior is important for prevention studies. The importance of the ability to detect intraductal cancer cannot be overemphasized, for several reasons: at least one-third of new cancers are detected at this intraductal stage, intervention at this stage represents the best opportunity for complete cure, and a significant number of invasive cancers contain an intraductal component. Without knowledge of the extent of the intraductal component, surgeons are unable to completely excise cancers about a third of the time, leading to unnecessary re-excisions or radiation therapy. Current investigations aimed at specifying best practices in radiotherapy of DCIS patients are stymied by the lack of objective quantitative methods of rapidly assessing response. Other future applications of PEM are suggested, including an information technology project built on PEM that promises to individualize therapy and facilitate surveillance of high risk populations. The high overall accuracy of PEM (i.e., both specificity and sensitivity) is an unusual and welcome development in the history of breast imaging. With this high accuracy, and continued technical innovation to reduce radiation dose, PEM may someday replace X-ray mammography as a first line approach to breast cancer detection.  相似文献   

3.
It has been proposed that the enhanced metabolic activity of tumor cells is accompanied by an increased expression of facilitative hexose transporters (GLUTs). However, a previous immunohistochemical analysis of GLUT1 expression in 154 malignant human neoplasms failed to detect the GLUT1 isoform in 87 tumors. We used 146 normal human tissues and 215 tumor samples to reassess GLUT1 expression. A similar number of samples were used to compare the expression of GLUT2-6 and 9. The classical expression of GLUT1-5 in different normal human tissues was confirmed, however, we were unable to detect GLUT2 in human pancreatic islet cells. GLUT6 was principally detected in testis germinal cells and GLUT9 was localized in kidney, liver, heart, and adrenal. In tumor samples, GLUT1, 2, and 5 were the main transporters detected. GLUT1 was the most widely expressed transporter, however, 42% of the samples had very low-to-negative expression levels. GLUT2 was detected in 31% of the samples, being mainly expressed in breast, colon, and liver carcinoma. GLUT5 was detected in 27% of breast and colon adenocarcinoma, liver carcinoma, lymphomas, and testis seminoma samples. In situ RT-PCR and ultrastructural immunohistochemistry confirmed GLUT5 expression in breast cancer. GLUT6 and 9 are not clearly over-expressed in human cancer. The extensive expression of GLUT2 and 5 (glucose/fructose and fructose transporters, respectively) in malignant human tissues indicates that fructose may be a good energy substrate in tumor cells. Our functional data obtained in vitro in different tumor cells support this hypothesis. Additionally, these results suggest that fructose uptake could be used for positron emission tomography imaging and, may possibly represent a novel target for the development of therapeutic agents in different human cancers.  相似文献   

4.
The aim of the study was to evaluate sensitivity and specificity of positron emission tomography (PET) and 18F-fluorodesoxyglucose (18F-FDG) in breast cancer diagnosis and to assess tumor dissemination. Sixty two patients were examined: 10 without mammary disease, 10 with fibrous cystic mastopathy, and 42 with breast cancer, which was hystologically verified. PET scanning was recorded in the "Whole body" mode 70-90 min later administration of 370-420 MBq 18F-FDG. It was shown that PET has a high diagnostic accuracy in breast cancer detection. There were no False-positive cases in our investigations. PET scanning in the "Whole body" mode was allowed to assess dissemination of tumor process with high accuracy. Metastatic involvement of local lymph nodes was detected in 82.8% cases and bone metastases--86% in cases.  相似文献   

5.
This study compared the detectability of simulated tumors using a high-energy X-ray inline phase sensitive digital breast tomosynthesis (DBT) prototype and a commercial attenuation-based DBT system. Each system imaged a 5-cm thick modular breast phantom with 50–50 adipose-glandular percentage density containing contrast-detail (CD) test objects to simulate different tumor sizes. A commercial DBT system acquired 15 projection views over 15 degrees (15d-15p) was used to acquire the attenuation-based projection views and to reconstruct the conventional DBT slices. Attenuation-based projection views were acquired at 32 kV, 46 mAs with a mean glandular dose (Dg) of 1.6 mGy. For acquiring phase sensitive projection views, the prototype utilized two acquisition geometries: 11 projection views were acquired over 15 degrees (15d-11p), and 17 projection views were acquired over 16 degrees (16d-17p) at 120 kV, 5.27 mAs with 1.51 mGy under the magnification (M) of 2. A phase retrieval algorithm based on the phase-attenuation duality (PAD) was applied to each projection view, and a modified Feldkamp-Davis-Kress (FDK) algorithm was used to reconstruct the phase sensitive DBT slices. Simulated tumor margins were rated as more conspicuous and better visualized for both phase sensitive acquisition geometries versus conventional DBT imaging. The CD curves confirmed the improvement in both contrast and spatial resolutions with the phase sensitive DBT imaging. The superiority of the phase sensitive DBT imaging was further endorsed by higher contrast to noise ratio (CNR) and figure-of-merit (FOM) values. The CNR improvements provided by the phase sensitive DBT prototype were sufficient to offset the noise reduction provided by the attenuation-based DBT imaging.  相似文献   

6.
Down-regulation of laminin-5 in breast carcinoma cells.   总被引:5,自引:0,他引:5       下载免费PDF全文
BACKGROUND: Laminin-5 (ln-5), a large heterotrimeric glycoprotein consisting of an alpha 3, beta 3, and gamma 2 chain, is a component of epithelial cell basement membranes that functions as a ligand of the alpha 3 beta 1 and alpha 6 beta 4 integrins to regulate cell adhesion, migration, and morphogenesis. The ln-5 chains show tissue-specific patterns of regulation in tumors derived from different tissues. For example, ln-5 is often up-regulated in gliomas, gastric carcinomas, and squamous carcinomas and down-regulated in prostate and basal cell carcinomas. Ln-5 expression patterns may represent useful tumor markers and help to elucidate the role of ln-5 in tumor progression in different tissue types. MATERIALS AND METHODS: We have studied ln-5 expression patterns in the breast. mRNA levels were examined in tumor and normal breast epithelial cell lines, tissue samples, and immunomagnetically sorted primary cultures using differential display, Northern blotting, and hybridization arrays. Protein levels were examined by immunoprecipitation. Gene integrity was assessed by Southern blotting of representative cell types. RESULTS: Ln-5 alpha 3, beta 3, and gamma 2 mRNA expression was found to be markedly down-regulated in a panel of breast tumor cell lines when compared with normal breast epithelial cells. Ln-5 mRNA was expressed at relatively high levels in MCF-10A immortal normal breast epithelial cells, long-term cultures of normal breast cells, and sorted primary cultures of normal breast luminal epithelial and myoepithelial cells. Reduced, but detectable, levels of ln-5 tended to be expressed in cell lines derived from early-stage breast tumors, whereas expression was generally not detected in cell lines derived from later-stage tumors. In breast tumor tissue specimens, expression of ln alpha 3 and beta 3 mRNAs tended to be reduced relative to levels observed in adjacent nontumor tissue, whereas in gamma 2 levels were elevated in specimens with increased amounts of myoepithelial cells. These ln-5 expression changes could not be attributed to large-scale mutations or gene rearrangements. Ln-5 protein levels were found to reflect mRNA levels in representative cell lines. At senescence, a growth state believed to suppress tumorigenesis, expression of all three ln-5 mRNAs was up-regulated. CONCLUSION: The down-regulation of ln-5 mRNA expression in breast tumors cells provides a new molecular marker and suggests that ln-5 functions to control tumor progression in the breast.  相似文献   

7.
Electrochemical treatment (EChT) with direct current delivered through implanted electrodes has been used for local control of solid tumors in humans. This study tested the hypothesis that rat breast cancer responses to EChT are dependent on electrode spacing and dose, and explored suitable parameters for treating breast cancers with EChT. Rat breast cancers were initiated by injecting 1 x 10(6) MTF-7 cells to the right mammary gland fat pad of Fisher 344 female rats. The rats were randomly divided into designated experimental groups when the tumors grew to approximately 2 x 2 x 2 cm. One hundred and thirty rats were used for a survival study and 129 for a pathology study. A 4-channel EChT machine was used to administer coulometric doses. The survival study indicated that local tumor control rate is less than 40% in the 40 coulomb (C) and 60 C groups and more than 70% in the 80 and 100 C groups. Sixty six rats died of primary tumors, including all 10 rats in the control group. Once a rat's primary tumor was controlled, no recurrence was found. The main reason for terminating the primary tumor-free rats (51) was lymph node metastasis. Thirteen tumor-free rats survived for more than 6 months. The pathology study showed a significant dose effect on EChT induced tumor necrosis. At 10, 20, 40, and 80 C, the fraction showing necrosis were 39.7, 52.3, 62, and 77.7%, respectively (P 相似文献   

8.
We evaluated the relationship between pre-treatment positron emission tomography (PET) using the hypoxic tracer 18F-[2-(2-nitro-1-H-imidazol-1-yl)-N-(2,2,3,3,3- pentafluoropropyl) acetamide] (18F-EF5) and the response of preclinical tumor models to a range of fractionated radiotherapies. Subcutaneous HT29, A549 and RKO tumors grown in nude mice were imaged using 18F-EF5 positron emission tomography (PET) in order to characterize the extent and heterogeneity of hypoxia in these systems. Based on these results, 80 A549 tumors were subsequently grown and imaged using 18F-EF5 PET, and then treated with one, two, or four fraction radiation treatments to a total dose of 10–40 Gy. Response was monitored by serial caliper measurements of tumor volume. Longitudinal post-treatment 18F-EF5 PET imaging was performed on a subset of tumors. Terminal histologic analysis was performed to validate 18F-EF5 PET measures of hypoxia. EF5-positive tumors responded more poorly to low dose single fraction irradiation relative to EF5-negative tumors, however both groups responded similarly to larger single fraction doses. Irradiated tumors exhibited reduced 18F-EF5 uptake one month after treatment compared to control tumors. These findings indicate that pre- treatment 18F-EF5 PET can predict the response of tumors to single fraction radiation treatment. However, increasing the number of fractions delivered abrogates the difference in response between tumors with high and low EF5 uptake pre-treatment, in agreement with traditional radiobiology.  相似文献   

9.
PURPOSE: We report on a novel preclinical pancreatic cancer research model that uses bioluminescence imaging (BLI)-guided irradiation of orthotopic xenograft tumors, sparing of surrounding normal tissues, and quantitative, noninvasive longitudinal assessment of treatment response. MATERIALS AND METHODS: Luciferase-expressing MiaPaCa-2 pancreatic carcinoma cells were orthotopically injected in nude mice. BLI was compared to pathologic tumor volume, and photon emission was assessed over time. BLI was correlated to positron emission tomography (PET)/computed tomography (CT) to estimate tumor dimensions. BLI and cone-beam CT (CBCT) were used to compare tumor centroid location and estimate setup error. BLI and CBCT fusion was performed to guide irradiation of tumors using the small animal radiation research platform (SARRP). DNA damage was assessed by γ-H2Ax staining. BLI was used to longitudinally monitor treatment response. RESULTS: Bioluminescence predicted tumor volume (R = 0.8984) and increased linearly as a function of time up to a 10-fold increase in tumor burden. BLI correlated with PET/CT and necropsy specimen in size (P < .05). Two-dimensional BLI centroid accuracy was 3.5 mm relative to CBCT. BLI-guided irradiated pancreatic tumors stained positively for γ-H2Ax, whereas surrounding normal tissues were spared. Longitudinal assessment of irradiated tumors with BLI revealed significant tumor growth delay of 20 days relative to controls. CONCLUSIONS: We have successfully applied the SARRP to a bioluminescent, orthotopic preclinical pancreas cancer model to noninvasively: 1) allow the identification of tumor burden before therapy, 2) facilitate image-guided focal radiation therapy, and 3) allow normalization of tumor burden and longitudinal assessment of treatment response.  相似文献   

10.
BackgroundThe calculation and measurement on the surface of the skin presents a significant dosimetric problem because of numerous factors which have an influence on the dose distribution in this region.AimThe overall aim of this study was to check the agreement between doses measured with thermoluminescent detectors (TLD) during tomotherapy photon beam irradiation of the skin area of a solid water cylindrical phantom with doses calculated with Hi-Art treatment planning system (TPS).Material and MethodThe measurements of the dose were made with the use of a solid water cylindrical phantom - Cheese Phantom. Two bolus phantoms were used: 5 mm and 10 mm Six different planning treatments were generated. The doses were measured using TL detectors.ResultsIn the case of a tumor located near the surface of the skin, the mean dose for 0.5 cm bolus was - 1.94 Gy, and for 1 cm bolus - 2.03 Gy. For the tumor located inside the phantom and organ at risk on the same side that TL detectors, for a 0.5 cm bolus, mean dose was 0.658 Gy, and for a 1 cm bolus, 0.62 Gy.ConclusionThe analysis of results showed that the relative percentage difference between measured and planned dose in the field of irradiation was less than 10%, while the largest differences were on the board of the field of radiation and outside of the field of irradiation, where the dose was 0.08 Gy to 1 Gy.  相似文献   

11.
Simultaneous, hybrid MR-PET is expected to improve PET image resolution in the plane perpendicular to the static magnetic field of the scanner. Previous papers have reported this either by simulation or experiment with simple sources and detector arrangements. Here, we extend those studies using a realistic brain phantom in a recently installed MR-PET system comprising a 9.4 T MRI-scanner and an APD-based BrainPET insert in the magnet bore. Point and line sources and a 3D brain phantom were filled with 18F (low-energy positron emitter), 68Ga (medium energy positron emitter) or 120I, a non-standard positron emitter (high positron energies of up to 4.6 MeV). Using the BrainPET insert, emission scans of the phantoms were recorded at different positions inside and outside the magnet bore such that the magnetic field was 0 T, 3 T, 7 T or 9.4 T. Brain phantom images, with the ‘grey matter’ compartment filled with 18F, showed no obvious resolution improvement with increasing field. This is confirmed by practically unchanged transaxial FWHM and ‘grey/white matter’ ratio values between at 0T and 9.4T. Field-dependent improvements in the resolution and contrast of transaxial PET images were clearly evident when the brain phantom was filled with 68Ga or 120I. The grey/white matter ratio increased by 7.3% and 16.3%, respectively. The greater reduction of the FWTM compared to FWHM in 68Ga or 120I line-spread images was in agreement with the improved contrast of 68Ga or 120I images. Notwithstanding elongations seen in the z-direction of 68Ga or 120I point source images acquired in foam, brain phantom images show no comparable extension. Our experimental study confirms that integrated MR-PET delivers improved PET image resolution and contrast for medium- and high-energy positron emitters even though the positron range is reduced only in directions perpendicular to the magnetic field.  相似文献   

12.
PurposeMagnetic Particle Imaging (MPI) is a new, background- and radiation-free tomographic imaging method that enables near real-time imaging of superparamagnetic iron-oxide nanoparticles (SPIONs) with high temporal and spatial resolution. This phantom study aims to investigate the potential of MPI for visualization of the stent lumen in intracranial flow diverters (FD).MethodsNitinol FD of different dimensions (outer diameter: 3.5 mm, 4.0 mm, 5.5 mm; total length: 22–40 mm) were scanned in vascular phantoms in a custom-built MPI scanner (in-plane resolution: ~ 2 mm, field of view: 65 mm length, 29 mm diameter). Phantoms were filled with diluted (1:50) SPION tracer agent Ferucarbotran (10 µmol (Fe)/ml; NaCL). Each phantom was measured in 32 different projections (overall acquisition time per image: 3200 ms, 5 averages). After image reconstruction from raw data, two radiologists assessed image quality using a 5-point Likert scale. The signal intensity profile was measured using a semi-automatic evaluation tool.ResultsMPI visualized the lumen of all FD without relevant differences between the stented vessel phantom and the reference phantom. At 3.5 mm image quality was slightly inferior to the larger diameters. The FD themselves neither generated an MPI signal nor did they lead to relevant imaging artifacts. Ratings of both radiologists showed no significant difference, interrater reliability was good (ICC 0.84). A quantitative evaluation of the signal intensity profile did not reveal any significant differences (p > 0.05) either.ConclusionMPI visualizes the lumen of nitinol FD stents in vessel phantoms without relevant stent-induced artifacts.  相似文献   

13.
OBJECTIVE: To evaluate the presence of allelic loss in 16q22.1, including the locus of E-cadherin, in pleural effusions in breast cancer patients. STUDY DESIGN: Molecular analysis of DNA was performed using a DNA extraction kit (NucleoSpin, Macherey-Nagel, Germany). Loss of heterozygosity (LOH) in primary tumors and pleural effusions was analyzed using a microsatellite marker of the CDH1 gene, D16S265, described in previous studies. LOH was evaluated by radioactive polymerase chain reaction assay in 17 samples of pleural effusions and breast tissues (primary tumors and nonneoplastic adjacent tissue) from breast cancer patients: 7 positive for neoplastic cells, 6 suspected and 4 cases without evidence of neoplastic cells in the effusions. RESULTS: Thirteen cases (76%) were informative. LOH was detected in 5 cases (38.5%). In 3 of them LOH was detected only in the cytologic sample, and in 2 of them LOH was detected in the primary tumor and cytologic sample. CONCLUSION: Results show that LOH in the CDH1 gene can identify tumor cells in pleural effusions when morphologic analysis is difficult.  相似文献   

14.
PURPOSE: To explore the effects of computed tomography (CT) slice thickness and reconstruction algorithm on quantification of image features to characterize tumors using a chest phantom. MATERIALS AND METHODS: Twenty-two phantom lesions of known sizes (10 and 20 mm), shapes (spherical, elliptical, lobulated, and spiculated), and densities [-630, -10, and +100 Hounsfield Unit (HU)] were inserted into an anthropomorphic thorax phantom and scanned three times with relocations. The raw data were reconstructed using six imaging settings, i.e., a combination of three slice thicknesses of 1.25, 2.5, and 5 mm and two reconstruction kernels of lung and standard. Lesions were segmented and 14 image features representing lesion size, shape, and texture were calculated. Differences in the measured image features due to slice thickness and reconstruction algorithm were compared using linear regression method by adjusting three confounding variables (size, density, and shape). RESULTS: All 14 features were significantly different between 1.25 and 5 mm slice images. The 1.25 and 2.5 mm slice thicknesses were better than 5 mm for volume, density mean, density SD gray-level co-occurrence matrix (GLCM) energy and homogeneity. As for the reconstruction algorithm, there was no significant difference in uni-dimension, volume, shape index 9, and compactness. Lung reconstruction was better for density mean, whereas standard reconstruction was better for density SD. CONCLUSIONS: CT slice thickness and reconstruction algorithm can significantly affect the quantification of image features. Thinner (1.25 and 2.5 mm) and thicker (5 mm) slice images should not be used interchangeably. Sharper and smoother reconstructions significantly affect the density-based features.  相似文献   

15.
Background: Human solid tumors undergo clonal evolution as they progress, but evidence for specific sequences of genetic changes that occur in individual tumors and are recapitulated in other tumors is difficult to obtain. Methods: Patterns of amplification of Her-2/neu, c-myc, and cyclin D1 were determined by fluorescence in situ hybridization (FISH) in relation to the presence of p53 dysfunction and ploidy in 60 primary human breast cancers. Results: We show that there are clusters of genophenotypic abnormalities that distinguish lobular breast cancers from nonlobular tumors; that cyclin D1 amplification occurs prior to the divergence of lobular breast cancers from nonlobular cancers; that p53 dysfunction, Her-2/neu amplification, and c-myc amplification are characteristic features of nonlobular breast cancers, but not of lobular breast cancers; and that the frequencies of amplification of all three oncogenes examined increase progressively with increasing aneuploidy, but that each gene exhibits a different profile of increasing amplification in relation to tumor progression. Early amplification of c-myc appears to be an especially prominent feature of hypertetraploid/hypertetrasomic tumors. Conclusions: The data suggest that in tumors containing multiple abnormalities, these abnormalities often accumulate in the same cells within each tumor. Furthermore, the same patterns of accumulation of multiple genophenotypic abnormalities are recapitulated in different tumors.  相似文献   

16.
This study was carried out to investigate the suitability of using the optically stimulated luminescence dosimeter (OSLD) in measuring surface dose during radiotherapy. The water equivalent depth (WED) of the OSLD was first determined by comparing the surface dose measured using the OSLD with the percentage depth dose at the buildup region measured using a Markus ionization chamber. Surface doses were measured on a solid water phantom using the OSLD and compared against the Markus ionization chamber and Gafchromic EBT3 film measurements. The effect of incident beam angles on surface dose was also studied. The OSLD was subsequently used to measure surface dose during tangential breast radiotherapy treatments in a phantom study and in the clinical measurement of 10 patients. Surface dose to the treated breast or chest wall, and on the contralateral breast were measured. The WED of the OSLD was found to be at 0.4 mm. For surface dose measurement on a solid water phantom, the Markus ionization chamber measured 15.95% for 6 MV photon beam and 12.64% for 10 MV photon beam followed by EBT3 film (23.79% and 17.14%) and OSLD (37.77% and 25.38%). Surface dose increased with the increase of the incident beam angle. For phantom and patient breast surface dose measurement, the response of the OSLD was higher than EBT3 film. The in-vivo measurements were also compared with the treatment planning system predicted dose. The OSLD measured higher dose values compared to dose at the surface (Hp(0.0)) by a factor of 2.37 for 6 MV and 2.01 for 10 MV photon beams, respectively. The measurement of absorbed dose at the skin depth of 0.4 mm by the OSLD can still be a useful tool to assess radiation effects on the skin dermis layer. This knowledge can be used to prevent and manage potential acute skin reaction and late skin toxicity from radiotherapy treatments.  相似文献   

17.
We present a method for depth discrimination in parallel-plate, transmission mode, diffuse optical imaging. The method is based on scanning a set of detector pairs, where the two detectors in each pair are separated by a distance δDi along direction δ D i within the x-y scanning plane. A given optical inhomogeneity appears shifted by αi δ D i (with 0≤ αi ≤1) in the images collected with the two detection fibers of the i-th pair. Such a spatial shift can be translated into a measurement of the depth z of the inhomogeneity, and the depth measurements based on each detector pair are combined into a specially designed weighted average. This depth assessment is demonstrated on tissue-like phantoms for simple inhomogeneities such as straight rods in single-rod or multiple-rod configurations, and for more complex curved structures which mimic blood vessels in the female breast. In these phantom tests, the method has recovered the depth of single inhomogeneities in the central position of the phantom to within 4 mm of their actual value, and within 7 mm for more superficial inhomogeneities, where the thickness of the phantom was 65 mm. The application of this method to more complex images, such as optical mammograms, requires a robust approach to identify corresponding structures in the images collected with the two detectors of a given pair. To this aim, we propose an approach based on the inner product of the skeleton images collected with the two detectors of each pair, and we present an application of this approach to optical in vivo images of the female breast. This depth discrimination method can enhance the spatial information content of 2D projection images of the breast by assessing the depth of detected structures, and by allowing for 3D localization of breast tumors.  相似文献   

18.
C-11- or F-18-DOPA positron emission tomography (DOPA PET) is a new sensitive imaging technique for small neuroendocrine gastrointestinal tumors which evaluates the decarboxylase activity. To further characterize the dopaminergic system in neuroendocrine gastrointestinal tumor cells, we investigated the expression of both dopamine receptors and the transmembrane dopamine transporter (DAT) in the human neuroendocrine pancreatic cell line BON and in the neuroendocrine gut cell line STC-1. Both BON and STC-1 cells expressed mRNA of the dopamine receptors D2-D5 and DAT. mRNA of the dopamine receptor D1 was detected in BON cells only. Both in BON and STC-1 cells, expression of D2 and D5 receptors and DAT was also demonstrated immunocytochemically. For functional receptor characterization intracellular cAMP levels ([cAMP]i) were determined. Whereas in STC-1 cells dopamine and the D1-like (D1/D5) receptor agonist SKF 38393 increased [cAMP]i, [cAMP]i was decreased by dopamine or the D2-like (D2-D4) receptor agonist quinpirole in BON cells. Functional DAT activity was, however, not detected in either cell line. The presence of both dopamine receptors and of the DAT suggests an autocrine and/or paracrine function of dopamine in neuroendocrine gastrointestinal tumor cells. Yet neither the transmembrane dopamine transporter nor dopamine receptors are likely to contribute to positive DOPA PET imaging of neuroendocrine gastrointestinal tumors. However, these molecules may be of diagnostic importance when applying other dopaminergic system tracers.  相似文献   

19.
The expression of mdm-2 oncoprotein (p90) was determined in a human breast tumor xenograft line (GI-101) that was derived from a 57 year old female cancer patient with recurrent, infiltrating ductal adenocarcinoma (Stage IIIa, T3N2MX). Immunoprecipitation coupled western blot analysis of the primary tumors that have been obtained from xenograft implanted athymic nude mice, using mdm-2 (Ab-1) mouse monoclonal antibody, primarily revealed high level expression of a 90 kD full length mdm-2 protein. In the GI-101 tumor the level of full length mdm-2 (p90) protein expression increased with the increase in the size of the tumor (100 to 2,000 mm(3)) and a maximum expression was detected in 2,000 mm(3) size tumors. In addition to the expression in the primary site, a significantly high level expression of mdm-2 protein (p90) was detected in the lung and liver tissues also, which are the known metastatic sites for GI-101 xenograft tumors. However, the level of mdm-2 protein expression was undetectable in the lung and liver tissues obtained from control mice. A cell line (GI-101A) derived from the GI-101 xenograft tumor also showed a high level expression of mdm-2 protein after several generations of cell passage. When the GI-101A cells were treated with DES (Diethylstilbestrol) the mdm-2 protein expression increased after 10 min treatment and reached a peak level at 40 min. Interestingly, DES (10 and 20 microM) treatment increased the total cell number also after 96 hr treatment compared to the non-treated cells. It appears that mdm-2 (p90) may have a significant role in supporting the tumor cell growth as well as the metastatic process of the GI-101A cells.  相似文献   

20.
Aromatase in the normal breast and breast cancer   总被引:9,自引:0,他引:9  
Adipose tissue and muscle constitute the larger proportion of body mass, and therefore aromatization in these tissues is the major source of circulating estrogens in postmenopausal women. Although plasma estrogen concentrations are very low, levels in breast cancers from postmenopausal patients are reported to be 10-fold higher than in plasma and normal tissue. Whereas studies on aromatase activity in the tumor suggest that estrogen may be produced locally, the significance of this contribution has been questioned. Using immunocytochemistry (ICC) to an anti-aromatase antibody, a relatively strong immunoreaction was detected in tumor epithelial cells as well as in the terminal ductal lobular units (TDLUs) of the normal breast. Aromatase expression was detected in the cytoplasm of tumor epithelial cells and the surrounding stromal cells of over 50% of tumors in a series of 19 breast cancers. In situ hybridization (ISH) to aromatase mRNA confirmed the immunocytochemical result that the epithelial cells are the primary site of estrogen synthesis in the breast and breast cancers. In the 10 tumors which showed immunoreaction to aromatase, the average aromatase activity measured in cryosections was 286.5 ± 18.6 fmol estrogen/mg protein/h (SE), whereas in nine tumors with weak aromatase immunoreaction, the enzyme activity was 154.7 ± 19.3 fmol estrogen/mg protein/h (P < 0.05) (SE). The functional significance of tumor aromatase and locally produced estrogens on the growth of tumors was suggested by the correlation between aromatase activity and proliferating cell nuclear antigen (PCNA), a marker of cell proliferation (P < 0.005). Although intratumoral aromatase activity did not correlate with steroid receptors significantly, there was a trend for estrogen receptor (ER)-positive tumors to express aromatase. In addition, proliferation ([3H]-thymidine incorporation into DNA) during histoculture, was increased by both estradiol and testosterone in tumors with high aromatase activity. Our results suggest that some tumors synthesize sufficient estrogen to stimulate their proliferation. It may thus be important to inhibit tumor aromatase as well as to reduce circulating levels of estrogen for effective breast cancer treatment.  相似文献   