首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
3.
Aims and objectivesTo compare dosimetrically the manual optimisation with IPSA using dose volume histograms (DVH) among patients treated for carcinoma of cervix with intracavitary brachytherapy.BackgroundWith the advent of advanced imaging modalities, there has been a shift from conventional X-ray based planning to three-dimensional planning. Manual optimisation is widely used across various institutions but it is time consuming and operator dependant. Inverse planning simulated annealing (IPSA) is now available in various brachytherapy planning systems. But there is a paucity of studies comparing manual optimisation and IPSA in treatment of carcinoma cervix with intracavitary brachytherapy and hence this study.Materials and methodsFifteen consecutive patients treated between December 2013 and March 2014 with intracavitary brachytherapy for carcinoma of cervix were selected for this study. All patients were initially treated with external beam radiotherapy followed by intracavitary brachytherapy. The DVH was evaluated and compared between manually optimised plans and IPSA in the same set of patients.ResultsThere was a significant improvement in the HRCTV coverage, mean V100 of 87.75% and 82.37% (p = 0.001) and conformity index 0.67 and 0.6 (p = 0.007) for plans generated using IPSA and manual optimisation, respectively. Homogeneity index and dose to the OARs remained similar between the two groups.ConclusionThe use of inverse planning in intracavitary brachytherapy of cervix has shown a significant improvement in the target volume coverage when compared with manual planning.  相似文献   

4.
AimTo present a proposed gastric cancer intensity-modulated radiotherapy (IMRT) treatment planning protocol for an institution that have not introduced volumetric modulated arc therapy in clinical practice. A secondary aim was to determine the impact of 2DkV set-up corrections on target coverage and organ at risk (OAR).Methods and MaterialsTwenty consecutive patients were treated with a specially-designed non-coplanar 7-field IMRT technique. The isocenter-shift method was used to estimate the impact of 2DkV-based set-up corrections on the original base plan (BP) coverage. An alternative plan was simulated (SP) by taking into account isocenter shifts. The SP and BP were compared using dose-volume histogram (DVH) plots calculated for the internal target volume (ITV) and OARs.ResultsBoth plans delivered a similar mean dose to the ITV (100.32 vs. 100.40%), with no significant differences between the plans in internal target coverage (5.37 vs. 4.96%). Similarly, no significant differences were observed between the maximal dose to the spinal cord (67.70 and 67.09%, respectively) and volume received 50% of the prescribed dose of: the liver (62.11 vs. 59.84%), the right (17.62 vs. 18.58%) and left kidney (29.40 vs. 30.48%). Set-up margins (SM) were computed as 7.80 mm, 10.17 mm and 6.71 mm in the left-right, cranio-caudal and anterior-posterior directions, respectively.ConclusionPresented IMRT protocol (OAR dose constraints with selected SM verified by 2DkV verification) for stomach treatment provided optimal dose distribution for the target and the critical organs. Comparison of DVH for the base and the modified plan (which considered set-up uncertainties) showed no significant differences.  相似文献   

5.
6.
Background and PurposeThe goal of our study was to quantify the limits of the EUD models for use in score functions in inverse planning software, and for clinical application.Materials and MethodsWe focused on oesophagus cancer irradiation. Our evaluation was based on theoretical dose volume histograms (DVH), and we analyzed them using volumetric and linear quadratic EUD models, average and maximum dose concepts, the linear quadratic model and the differential area between each DVH.ResultsWe evaluated our models using theoretical and more complex DVHs for the above regions of interest. We studied three types of DVH for the target volume: the first followed the ICRU dose homogeneity recommendations; the second was built out of the first requirements and the same average dose was built in for all cases; the third was truncated by a small dose hole. We also built theoretical DVHs for the organs at risk, in order to evaluate the limits of, and the ways to use both EUD(1) and EUD/LQ models, comparing them to the traditional ways of scoring a treatment plan. For each volume of interest we built theoretical treatment plans with differences in the fractionation.ConclusionWe concluded that both volumetric and linear quadratic EUDs should be used. Volumetric EUD(1) takes into account neither hot–cold spot compensation nor the differences in fractionation, but it is more sensitive to the increase of the irradiated volume. With linear quadratic EUD/LQ, a volumetric analysis of fractionation variation effort can be performed.  相似文献   

7.
PurposeTo investigate the clinical significance of introducing model based dose calculation algorithms (MBDCAs) as an alternative to TG-43 in 192Ir interstitial breast brachytherapy.Materials and methodsA 57 patient cohort was used in a retrospective comparison between TG-43 based dosimetry data exported from a treatment planning system and Monte Carlo (MC) dosimetry performed using MCNP v. 6.1 with plan and anatomy information in DICOM-RT format. Comparison was performed for the target, ipsilateral lung, heart, skin, breast and ribs, using dose distributions, dose-volume histograms (DVH) and plan quality indices clinically used for plan evaluation, as well as radiobiological parameters.ResultsTG-43 overestimation of target DVH parameters is statistically significant but small (less than 2% for the target coverage indices and 4% for homogeneity indices, on average). Significant dose differences (>5%) were observed close to the skin and at relatively large distances from the implant leading to a TG-43 dose overestimation for the organs at risk. These differences correspond to low dose regions (<50% of the prescribed dose), being less than 2% of the prescribed dose. Detected dosimetric differences did not induce clinically significant differences in calculated tumor control probabilities (mean absolute difference <0.2%) and normal tissue complication probabilities.ConclusionWhile TG-43 shows a statistically significant overestimation of most indices used for plan evaluation, differences are small and therefore not clinically significant. Improved MBDCA dosimetry could be important for re-irradiation, technique inter-comparison and/or the assessment of secondary cancer induction risk, where accurate dosimetry in the whole patient anatomy is of the essence.  相似文献   

8.
《IRBM》2014,35(5):255-261
PurposeThis work sought to establish whether the choice of CT scanner calibration curve has a significant effect on dose computation using density correction methods for chest cancer.Material and methodsCIRS®062 phantom was used to calculate the Hounsfield Unit using 80, 120 and 140 kV. Four CT calibration curves were implanted in the Eclipse® TPS. Forty-two irradiation fields for 4 patients with lung cancer were included and analysed. The patients were treated with 3-dimensional radiation therapy. For each patient, 3 treatment plans were generated using exactly the same beam configuration. In plan 1, the dose was calculated using the Modified Batho (MB) method. In plan 2, the dose was calculated using the Batho power law (BPL) method. In plan 3, the dose was calculated using the Equivalent Tissue Air Ratio (ETAR) method. To evaluate the treatment plans computed by the three methods, the monitor units, dose volume histograms, conformity index, homogeneity index, planning target volumes conformity index, geometrical index and 2D gamma index were compared. The statistical analysis was carried out using Wilcoxon signed rank test.ResultsThe three density correction methods in plans 1, 2 and 3 using tested curves produced a difference less than 1% for MUs and DVH. Wilcoxon test showed a statically significant difference for MUs using ETAR method with calibration curves based on 80 and 120 kV. There was no significant difference for the quality indices between plan 1, 2 and 3, (P > 0.05), but a significant difference for the planning target volumes conformity index between plans 1, 2 and 3 (P < 0.05) was observed. The 2D gamma analysis showed that 100% of pixels had gamma  1.ConclusionThe impact of the modification of CT calibration curves on dose is negligible for chest cancer using density correction methods. One calibration curve can be used to take into account the density correction for lung.  相似文献   

9.
10.

Aim

The aim of this study was to investigate the sensitivity of the trajectory log file based quality assurance to detect potential errors such as MLC positioning and gantry positioning by comparing it with EPID measurement using the most commonly used criteria of 3%/3?mm.

Materials and methods

An in-house program was used to modified plans using information from log files, which can then be used to recalculate a new dose distribution. The recalculated dose volume histograms (DVH) were compared with the originals to assess differences in target and critical organ dose. The dose according to the differences in DVH was also compared with dosimetry from an electronic portal imaging device.

Results

In all organs at risk (OARs) and planning target volumes (PTVs), there was a strong positive linear relationship between MLC positioning and dose error, in both IMRT and VMAT plans. However, gantry positioning errors exhibited little impact in VMAT delivery. For the ten clinical cases, no significant correlations were found between gamma passing rates under the criteria of 3%/3?mm for the composite dose and the mean dose error in DVH (r?<?0.3, P?>?0.05); however, a significant positive correlation was found between the gamma passing rate of 3%/3?mm (%) averaged over all fields and the mean dose error in the DVH of the VMAT plans (r?=?0.59, P?<?0.001).

Conclusions

This study has successfully shown the sensitivity of the trajectory log file to detect the impact of systematic MLC errors and random errors in dose delivery and analyzed the correlation of gamma passing rates with DVH.  相似文献   

11.
BackgroundThis dosimetric study aims to evaluate the dosimetric advantage of the irregular surface compensator (ISC) compared with the intensity-modulated radiotherapy (IMRT).Materials and methodsTen patients with whole breast irradiation were planned with the ISC and IMRT techniques. Six different beam directions were selected for IMRT and ISC plans. The treatment plans were evaluated with respect to planning target coverage, dose homogeneity index (DHI) and organs at risk (OARs) sparing. Monitor units (MUs) and the delivery time were analysed for treatment efficiency.ResultsThe ISC technique provides a better coverage of the PTV and statistically significantly better homogeneity of the dose distribution. For the ipsilateral lung and heart, ISC and IMRT techniques deliver almost the same dose in all plans. However, MU counts and delivery time were significantly lower with the IMRT technique (p < 0.05).ConclusionFor breast radiotherapy, when the ISC method was compared to the IMRT method, ISC provided better dose distribution for the target.  相似文献   

12.
PurposeRadiation therapy plans are assessed using dose volume metrics derived from clinical toxicity and outcome data. In this study, plans for patients with locally advanced non-small cell lung cancer (LA-NSCLC) are examined in the context of the implementation of the Acuros XB (AXB) dose calculation algorithm focussing on the impact on common metrics. Methods: Volumetric modulated arc therapy (VMAT) plans were generated for twenty patients, using the Analytical Anisotropic Algorithm (AAA) and recalculated with AXB for both dose to water (Dw) and dose to medium (Dm). Standard dose volume histogram (DVH) metrics for both targets and organs-at-risk (OARs) were extracted, in addition to tumour control probability (TCP) for targets. Results: Mean dose to the planning target volume (PTV) was not clinically different between the algorithms (within ±1.1 Gy) but differences were seen in the minimum dose, D99% and D98% as well as for conformity and homogeneity metrics. A difference in TCP was seen for AXBDm plans versus both AXBDw and AAA plans. No clinically relevant differences were seen in the lung metrics. For point doses to spinal cord and oesophagus, the AXBDm values were lower than AXBDw, by up to 1.0 Gy. Conclusion: Normalisation of plans to the mean/median dose to the target does not need to be adjusted when moving from AAA to AXB. OAR point doses may decrease by up to 1 Gy with AXBDm, which can be accounted for in clinical planning. Other OAR metrics do not need to be adjusted.  相似文献   

13.
PurposeTo investigate the feasibility of carotid sparing intensity modulated radiation therapy (CS-IMRT) to minimize the radiation dose to carotid arteries for comprehensive irradiation of breast cancer patients who have risk factors for atherosclerosis. The dose distribution of CS-IMRT technique and the conventional irradiation technique were also compared.Patients and methodsTen patients who were previously treated with comprehensive three-dimensional conformal radiation therapy (3DCRT) were selected. DICOM data were used to contour the carotid artery and to create the virtual CS-IMRT plans for each patient. 3DCRT and CS-IMRT plans were compared in terms of conformity index, homogeneity index, and the doses to organ at risk and carotid arteries.ResultsThe homogeneity and conformity indices were better with CS-IMRT plans compared to 3DCRT plan. The homogeneity index was 1.13 vs 1.11 (p = 0.007) for 3DCRT and CS-IMRT and the conformity index was 0.96 vs 0.97 (p = 0.006) for 3DCRT and CS-IMRT. The radiation dose to the carotid arteries were reduced by applying CS-IMRT without compromising the target volume coverage. When the carotid artery was considered as organ at risk for CS-IMRT planning, the median of V50 was decreased to 0% from 12.5% compared to 3DCRT plans (p = 0.017). The median of the maximum dose to the carotid artery was decreased under 50 Gy with CS-IMRT.ConclusionsCS-IMRT can significantly reduce the unnecessary radiation dose to the carotid arteries compared with conventional 3DCRT technique while maintaining target volume coverage. CS-IMRT technique can be considered for breast cancer patient with high risk of atherosclerosis.  相似文献   

14.
15.
The aim of this paper is to evaluate clinically relevant quality assurance (QA) tests for RapidArc prostate patients. 26 plans were verified by the COMPASS system that provides an independent angle response and a reconstruction of dose distribution in patient CT model. Plan data were imported from treatment planning system via DICOM. The fluencies, measured by a 2D detector, were used by COMPASS to forward calculate dose in CT patients and reconstruct dose-volume-histogram (DVH). The gamma analysis was performed, using both the criteria 3%-3-mm and 2%-2 mm, for the whole grid patient and the per-structure volume. A DVH-based analysis was accomplished for target and organs-at-risk (OAR). The correlation between gamma passing rates and DVH discrepancies was performed using Pearson's test. Sensitivity, specificity and accuracy of whole and per-structure gamma method were calculated.No significant DVH deviation was observed for target and OAR. Weak correlation between gamma passing rates and dosimetric deviations was observed, all significant r-values were negative. The whole gamma method shows lack of sensitivity to detect dosimetric deviations >5%. Instead, a better balance between sensitivity and specificity was obtained employing per structure gamma both with 3%-3 mm and 2%-2 mm criteria.Because of the poor correlation between DVH goals and gamma passing rates, we encourage the DVH-based gamma passing rates, when it is possible. At least, a gamma method specific for structure was strongly suggested.  相似文献   

16.
PurposeTo compare target volume coverage and critical organ dosimetry of intraoperative treatment plans for loose seed (LS) and stranded seed (SS) 125I permanent implants for low and intermediate risk prostate cancer.MethodsTwo hundred and five patients who underwent permanent seed brachytherapy were included in the study. For prostate dosimetry V90, V100, V150, V200, D90 and COIN were used. The dose to urethra and rectum was determined by the maximal dose and relative doses that cover specified volumes. Means and standard deviations were calculated and statistically compared.ResultsOn average, 54 (range, 30–78) and 48 (range, 31–67) seeds were implanted in the prostate with individual median activities of 0.62 U (range, 0.520.70 U) and 0.71 U (range, 0.65–0.71 U) for LS and SS technique, respectively. The target coverage was slightly better with SS (V100: 98% vs. 96%, p < 0.05; D90: 172 Gy vs. 166 Gy, p < 0.05), but more conformal dose distributions were observed with LS (COIN: 0.70 vs. 0.63, p < 0.05). The dose homogeneity did not differ significantly between the two groups. Regarding the dose to urethra and rectum all dose parameters were significantly lower with LS.ConclusionsLS resulted in less dose to the urethra and rectum compared to SS in intraoperative dosimetry. A slightly better target volume coverage with decreased conformity of dose distribution is reported with SS. More studies are necessary to determine how these results will affect postoperative dosimetry, and ultimately, clinical outcome.  相似文献   

17.
PurposeThis paper analyzes Tomotherapy-based intracranial stereotactic radiosurgery (HTSRS) of brain metastasis targeting two end-points: 1) evaluation of dose homogeneity, conformity and gradient scores for single and multiple lesions and 2) assay of dosimetric criticality of completion of HTSRS procedures.Methods42 treatment plans of 33 patients (53 brain lesions) treated with HTSRS were analyzed. Dose to healthy brain, homogeneity, conformity and gradient indexes were evaluated for each lesion. Influence of Field Length and multiple lesions cross-talk effect were assessed. Treatment interruption and completion was investigated using radiochromic films in order to examine the delivered dose and its robustness to patient intrafraction movement.ResultsThe average dose homogeneity index was 1.04 ± 0.02 (SD). Average dose conformity and gradient score indexes were 1.4 ± 0.2 and 50 ± 14 respectively. We found a strong correlation of the dose to healthy brain and conformity and gradient indexes with target(s) volume for which analytical functions were obtained. Field Length and cross-talk effect were significantly correlated with poor gradient scores, but were found not to affect dose conformity.ConclusionsHomogeneity and conformity of HTSRS plans achieved excellent scores, while dose falloff and dose to healthy brain were slightly larger when compared with non-coplanar SRS techniques. Care should be given if treating large (>3 cc) or multiple near in-plane lesions in order to reduce dose to healthy brain. Analysis of interrupted treatments suggests splitting HTSRS treatments in two consecutive fractions in order to prevent target miss and overdosage due to patient intrafraction movement.  相似文献   

18.
Background and purposeHelical tomotherapy (HT) can deliver highly conformal, uniform doses to the target volume. However, HT can only be delivered in a coplanar mode.The purpose of this study was to perform a dosimetric comparison of HT versus coplanar (cIMRT) and non-coplanar (n-cIMRT) beam arrangements on a conventional linear accelerator in a diverse group of brain tumors.Materials and methodsA total of 45 treatment plans were calculated retrospectively for 15 cases. For each case, 3 different delivery techniques (n-cIMRT, cIMRT and HT) were used. The treatment plans were compared using the parameters of the target coverage (conformity index; CI) and homogeneity (HI) for the planning target volume (PTV) and the maximum and mean doses for organs at risk (OARs).ResultsMedian HI and CI were the best for HT plans and the worst for cIMRT. The largest reduction of maximum dose for lenses and mean dose for both eyes was achieved for n-cIMRT plans. Mean dose for chiasm and the ipsilateral optic nerve were the lowest for HT. The contralateral optic nerve was most spared with n-cIMRT. For D1% in the brain stem, there was no significant difference between HT and the IMRT plans.ConclusionsBoth HT and n-cIMRT are capable of producing conformal and homogeneous treatment plans with a good sparing of OARs. However, due to the non-coplanar capabilities of IMRT, n-cIMRT led to a superior dose reduction to the lenses.  相似文献   

19.
20.

Aim

This prospective study aims to assess feasibility of helical tomotherapy (HT) for craniospinal irradiation (CSI) and perform dosimetric comparison of treatment plans for both HT and 3D conformal radiotherapy (3DCRT).

Background

CSI is a challenging procedure. Large PTV size requires field matching due to technical limitations of standard linear accelerators, which cannot irradiate such volumes as a single field. HT could help to avoid these limitations as irradiation of long fields is possible without field matching.

Materials and methods

Three adults were enrolled from 2009 to 2010. All patients received radiochemotherapy. Treatment plans in prone position for 3DCRT and in supine position for HT were generated. The superior plan was used for patients’ irradiation. Plans were compared with the application of DVH, Dx parameters – where x represents a percentage of the structure volume receiving a normalized dose and homogeneity index (HI).

Results

All patients received HT irradiation. The treatment was well tolerated. The HT plans resulted in a better dose coverage and uniformity in the PTV: HI were 5.4, 7.8, 6.8 for HT vs. 10.3, 6.6, 10.4 for 3DCRT. For most organs at risk (OARs), the D(V80) was higher for HT than for 3DCRT, whereas D(V5) was lower for HT.

Conclusions

HT is feasible for CSI, and in comparison with 3DCRT it improves PTV coverage. HT reduces high dose volumes of OARs, but larger volumes of normal tissue receive low radiation dose. HT requires further study to establish correlations between dosimetrical findings and clinical outcomes, especially with regard to late sequelae of treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号