1.
We are developing a high resolution, high sensitivity PET camera dedicated to breast cancer imaging. We are studying two novel detector technologies for this imaging system: a scintillation detector comprising layers of small lutetium oxyorthosilicate (LSO) crystals coupled to new position sensitive avalanche photodiodes (PSAPDs), and a pure semiconductor detector comprising cadmium zinc telluride (CZT) crystal slabs with thin anode and cathode strips deposited in orthogonal directions on either side of each slab. Both detectors achieve 1 mm spatial resolution with 3–5 mm directly measured photon interaction depth resolution, which promotes uniform reconstructed spatial resolution throughout a compact, breast-size field of view. Both detector types also achieve outstanding energy resolution (<3% and <12%, respectively for LSO-PSAPD and CZT at 511 keV). This paper studies the effects that this excellent energy resolution has on the expected system performance. Results indicate the importance that high energy resolution and narrow energy window settings have in reducing background random as well as scatter coincidences without compromising statistical quality of the dedicated breast PET data. Simulations predict that using either detector type the excellent performance and novel arrangement of these detectors proposed for the system facilitate ∼20% instrument sensitivity at the system center and a peak noise-equivalent count rate of >4 kcps for 200 microCi in a simulated breast phantom.  相似文献   

2.
The Hybrid Compact Gamma Camera (HCGC) is a small field of view (SFOV) portable hybrid gamma-optical camera intended for small organ imaging at the patient bedside. In this study, a thyroid phantom was used to determine the suitability of the HCGC for clinical thyroid imaging through comparison with large field of view (LFOV) system performance.A direct comparison with LFOV contrast performance showed that the lower sensitivity of the HCGC had a detrimental effect on image quality. Despite this, the contrast of HCGC images exceeded those of the LFOV cameras for some image features particularly when a high-resolution pinhole collimator was used.A clinical simulation showed that thyroid morphology was visible in a 5 min integrated image acquisition with an expected dependency on the activity within the thyroid. The first clinical use of the HCGC for imaging thyroid uptake of 123I is also presented.Measurements indicate that the HCGC has promising utility in thyroid imaging, particularly as its small size allows it to be brought into closer proximity with a patient. Future development of the energy response of the HCGC is expected to further improve image detectability.  相似文献   

3.
The aim of this work was to assess the performance of a prototype compact gamma camera (MediPROBE) based on a CdTe semiconductor hybrid pixel detector, for coded aperture imaging. This probe can be adopted for various tasks in nuclear medicine such as preoperative sentinel lymph node localization, breast imaging with 99mTc radiotracers and thyroid imaging, and in general in radioguided surgery tasks. The hybrid detector is an assembly of a 1-mm thick CdTe semiconductor detector bump-bonded to a photon-counting CMOS readout circuit of the Medipix2 series or energy-sensitive Timepix detector. MediPROBE was equipped with a set of two coded aperture masks with 0.07-mm or 0.08-mm diameter holes. We performed laboratory measurements of field of view, system spatial resolution, and signal-difference-to-noise ratio, by using gamma-emitting radioactive sources (109Cd, 125I, 241Am, 99mTc). The system spatial resolution in the lateral direction was 0.56 mm FWHM (coded aperture mask with holes of 0.08 mm and a 60 keV source) at a source-collimator distance of 50 mm and a field of view of 40 mm by side. Correspondingly, the longitudinal resolution in 3D source localization tasks was about 3 mm. MediPROBE showed a significant improvement in terms of spatial resolution when equipped with the high-resolution coded apertures, with respect to the performance previously reported with 1–2 mm pinhole apertures as well as with respect to adopting a 0.35 mm pinhole aperture.  相似文献   

4.
A handheld, high-resolution small field of view (SFOV) pinhole gamma camera has been characterised using a new set of protocols adapted from standards previously developed for large field of view (LFOV) systems. Parameters investigated include intrinsic and extrinsic spatial resolution, spatial linearity, uniformity, sensitivity, count rate capability and energy resolution. Camera characteristics are compared to some clinical LFOV gamma cameras and also to other SFOV cameras in development.  相似文献   

5.
New technologies are available in myocardial perfusion imaging. They include new software that recovers image resolution and limits image noise, multifocal collimators and dedicated cardiac cameras in which solid-state detectors are used and all available detectors are constrained to imaging just the cardiac field of view.These innovations resulted in shortened study times or reduced administered activity to patients, while preserving image quality.Many single center and some multicenter studies have been published during the introduction of these innovations in the clinical practice. Most of these studies were lead in the framework of “agreement studies” between different methods of clinical measurement. They aimed to demonstrate that these new software/hardware solutions allow the acquisition of images with reduced acquisition time or administered activity with comparable results (as for image quality, image interpretation, perfusion defect quantification, left ventricular volumes and ejection fraction) to the standard-time or standard-dose SPECT acquired with a conventional gamma camera and reconstructed with the traditional FBP method, considered as the gold standard.The purpose of this review is to provide the reader with a comprehensive understanding of the pro and cons of the different approaches summarizing the achievements reached so far and the issues that need further investigations.  相似文献   

6.
We introduce and demonstrate the utility of coded aperture (CA) nuclear scintigraphy for imaging small animals. CA imaging uses multiple pinholes in a carefully designed mask pattern, mounted on a conventional gamma camera. System performance was assessed using point sources and phantoms, while several animal experiments were performed to test the usefulness of the imaging system in vivo, with commonly used radiopharmaceuticals. The sensitivity of the CA system for 99mTc was 4.2 x 10(3) cps/Bq (9400 cpm/microCi), compared to 4.4 x 10(4) cps/Bq (990 cpm/microCi) for a conventional collimator system. The system resolution was 1.7 mm, as compared to 4-6 mm for the conventional imaging system (using a high-sensitivity low-energy collimator). Animal imaging demonstrated artifact-free imaging with superior resolution and image quality compared to conventional collimator images in several mouse and rat models. We conclude that: (a) CA imaging is a useful nuclear imaging technique for small animal imaging. The advantage in signal-to-noise can be traded to achieve higher resolution, decreased dose or reduced imaging time. (b) CA imaging works best for images where activity is concentrated in small volumes; a low count outline may be better demonstrated using conventional collimator imaging. Thus, CA imaging should be viewed as a technique to complement rather than replace traditional nuclear imaging methods. (c) CA hardware and software can be readily adapted to existing gamma cameras, making their implementation a relatively inexpensive retrofit to most systems.  相似文献   

7.
The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone''s camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples.  相似文献   

8.
For three-dimensional (3D) structure determination of large macromolecular complexes, single-particle electron cryomicroscopy is considered the method of choice. Within this field, structure determination de novo, as opposed to refinement of known structures, still presents a major challenge, especially for macromolecules without point-group symmetry. This is primarily because of technical issues: one of these is poor image contrast, and another is the often low particle concentration and sample heterogeneity imposed by the practical limits of biochemical purification. In this work, we tested a state-of-the art 4 k x 4 k charge-coupled device (CCD) detector (TVIPS TemCam-F415) to see whether or not it can contribute to improving the image features that are especially important for structure determination de novo. The present study is therefore focused on a comparison of film and CCD detector in the acquisition of images in the low-to-medium ( approximately 10-25 A) resolution range using a 200 kV electron microscope equipped with field emission gun. For comparison, biological specimens and radiation-insensitive carbon layers were imaged under various conditions to test the image phase transmission, spatial signal-to-noise ratio, visual image quality and power-spectral signal decay for the complete image-processing chain. At all settings of the camera, the phase transmission and spectral signal-to-noise ratio were significantly better on CCD than on film in the low-to-medium resolution range. Thus, the number of particle images needed for initial structure determination is reduced and the overall quality of the initial computed 3D models is improved. However, at high resolution, film is still significantly better than the CCD camera: without binning of the CCD camera and at a magnification of 70 kx, film is better beyond 21 A resolution. With 4-fold binning of the CCD camera and at very high magnification (> 300 kx) film is still superior beyond 7 A resolution.  相似文献   

9.
A system for taking static thyroid 99mTc images was devised by using multiple imaging plates (IPs) and a low-energy high resolution collimator. System spatial resolution of the IP systems and the gamma camera was determined by referring to standards set by the National Electrical Manufacturers Association. Sensitivity was represented by using lower detection limits (LDLs). The sensitivity and resolution of IP systems using 16 IP probes connecting two collimators and 9 IPs were determined by using a 20 ml thyroid phantom, and compared with the sensitivity of gamma cameras. The sensitivity of the IP systems increased in proportion to the number of IPs. The sensitivity and resolution of a probe using 6 IPs and a high resolution collimator were equivalent to or superior to the gamma camera for taking static thyroid 99mTc images. IP systems can be applied clinically as mobile static nuclear imaging devices. The performance of IP systems should be thoroughly investigated for combinations of various collimators and the number of IPs in order to verify their efficacy for imaging all organs.  相似文献   

10.
The small-animal High-Resolution SPECT (HiReSPECT) is a dedicated dual-head gamma camera recently designed and developed in our laboratory for imaging of murine models. Each detector is composed of an array of 1.2 × 1.2 mm2 (pitch) pixelated CsI(Na) crystals. Two position-sensitive photomultiplier tubes (H8500) are coupled to each head's crystal. In this paper, we report on a resolution-recovery-embedded image reconstruction code applicable to the system and present the experimental results achieved using different phantoms and mouse scans. Collimator-detector response functions (CDRFs) were measured via a pixel-driven method using capillary sources at finite distances from the head within the field of view (FOV). CDRFs were then fitted by independent Gaussian functions. Thereafter, linear interpolations were applied to the standard deviation (σ) values of the fitted Gaussians, yielding a continuous map of CDRF at varying distances from the head. A rotation-based maximum-likelihood expectation maximization (MLEM) method was used for reconstruction. A fast rotation algorithm was developed to rotate the image matrix according to the desired angle by means of pre-generated rotation maps. The experiments demonstrated improved resolution utilizing our resolution-recovery-embedded image reconstruction. While the full-width at half-maximum (FWHM) radial and tangential resolution measurements of the system were over 2 mm in nearly all positions within the FOV without resolution recovery, reaching around 2.5 mm in some locations, they fell below 1.8 mm everywhere within the FOV using the resolution-recovery algorithm. The noise performance of the system was also acceptable; the standard deviation of the average counts per voxel in the reconstructed images was 6.6% and 8.3% without and with resolution recovery, respectively.  相似文献   

11.
We have developed and tested a GSO position sensitive gamma detector which can be used with positron and single-photon radionuclides for imaging breast cancer or sentinel lymph node detection. Because GSO has a relatively good energy resolution for annihilation gammas as well as low energy gamma photons, and does not contain any natural radioisotopes it can be used for positron imaging and lower energy single-photon imaging. The imaging detector consists of a GSO block, 2-inch square multichannel position sensitive photo-multiplier tube (PSPMT), and associated electronics. For the positron imaging, coincidence between the imaging detector and a single gamma probe is measured. For the single-photon imaging, a tungsten collimator is mounted in front of the imaging detector. With this configuration, it was possible to image both positron radionuclides and low energyu single-photon radionuclides.  相似文献   

12.
Several efforts have been focusing on the development of detectors devoted to high solution 99mTc sestamibi scintimammography to improve sensitivity for non palpable lesions. To this aim new high resolution scintillation gamma camera was developed under the “Integiated Mammographic Imaging” project. The gamma camera, made by CAEN and Pol.Hi.Tech, has an overall dimension of 112×120×75mm3. It consists of an array of 1 in. PSPMTs Hamamatsu H8520-C12 closely packed, a NaI(T1) scintillation array (1.8×1.8×6mm3 pixel) and a general purpose collimator. By this gamma camera a clinical experience on a few patients with breast cancer suspicion was performed. In this paper we show how high resolution approach allows to better categorize the lesions on the basis of the morphology of the spatial distribution of the radiotracer in the breast tissue. By comparing conventional and high resolution images of a young patient (29 y.o.) with breast cancer suspicion, it appears clear how the Anger, camera images showed a defined hot spot, highly suggestive of malignant lesion; on the contrary, the high resolution scan shown a large and inhomogeneous uptake area with the absence of clear and focal character of the uptake, to be considered as a probably non malignant lesions. This resuh was confirmed by byoptical findings that diagnosed the echographic findings as a benign inflammatory lesion.  相似文献   

13.
Single-molecule switching nanoscopy overcomes the diffraction limit of light by stochastically switching single fluorescent molecules on and off, and then localizing their positions individually. Recent advances in this technique have greatly accelerated the data acquisition speed and improved the temporal resolution of super-resolution imaging. However, it has not been quantified whether this speed increase comes at the cost of compromised image quality. The spatial and temporal resolution depends on many factors, among which laser intensity and camera speed are the two most critical parameters. Here we quantitatively compare the image quality achieved when imaging Alexa Fluor 647-immunolabeled microtubules over an extended range of laser intensities and camera speeds using three criteria – localization precision, density of localized molecules, and resolution of reconstructed images based on Fourier Ring Correlation. We found that, with optimized parameters, single-molecule switching nanoscopy at high speeds can achieve the same image quality as imaging at conventional speeds in a 5–25 times shorter time period. Furthermore, we measured the photoswitching kinetics of Alexa Fluor 647 from single-molecule experiments, and, based on this kinetic data, we developed algorithms to simulate single-molecule switching nanoscopy images. We used this software tool to demonstrate how laser intensity and camera speed affect the density of active fluorophores and influence the achievable resolution. Our study provides guidelines for choosing appropriate laser intensities for imaging Alexa Fluor 647 at different speeds and a quantification protocol for future evaluations of other probes and imaging parameters.  相似文献   

14.
Radioluminescence microscopy (RLM) is a high‐resolution method for imaging radionuclide uptake in live cells within a fluorescence microscopy environment. Although RLM currently provides sufficient spatial resolution and sensitivity for cell imaging, it has not been systematically optimized. This study seeks to optimize the parameters of the system by computational simulation using a combination of numerical models for the system's various components: Monte‐Carlo simulation for radiation transport, 3D optical point‐spread function for the microscope, and stochastic photosensor model for the electron multiplying charge coupled device (EMCCD) camera. The relationship between key parameters and performance metrics relevant to image quality is examined. Results show that Lu2O3:Eu yields the best performance among 5 different scintillator materials, and a thickness: 8 μm can best balance spatial resolution and sensitivity. For this configuration, a spatial resolution of ~20 μm and sensitivity of 40% can be achieved for all 3 magnifications investigated, provided that the user adjusts pixel binning and electron multiplying (EM) gain accordingly. Hence the primary consideration for selecting the magnification should be the desired field of view and magnification for concurrent optical microscopy studies. In conclusion, this study estimates the optimal imaging performance achievable with RLM and promotes further development for more robust imaging of cellular processes using radiotracers.   相似文献   

15.
Mammography remains the gold standard in breast cancer detection, although there remains a challenge for improvement in sensitivity of breast cancer detection and diagnosis. Although mammography is the most frequently utilized examination to screen for breast cancer, which has resulted in a reduction of breast cancer mortality, still some cancers are unable to be visualized on mammographic images. Mammography films are interpreted using an anatomic approach. A new approach to breast cancer diagnosis utilizes a breast specific gamma camera to measure radiotracer uptake of abnormal tissue in the breast in patients with an abnormal mammogram or palpble mass using technetium sestamibi. Images are taken using the same positioning techniques as mammography for comparison of both types of images. Multi-Institutional trials using a traditional gamma camera demonstrated potential for this approach. However, the inability of traditional gamma camera intrinsic resolution and non-optinuized breast imaging limited scintimammography. Therefore, a breast specific, high resolution gamma camera was developed to overcome these limitations.Results of clinical studies evaluating BSGI are promising and are increasingly being used. Additionally, means for minimally invasive imaging-guided acquisition of tissue are being developed so that biopsies will be avaibles for areas of interest based on radiotracer uptake.Breast specific gamma camera nuclear imaging of the breast is a developing and increasingly utilized approach to improving breast cancer detection and diagnosis.  相似文献   

16.
Scintimair mography is a molecular breast imaging technique using tumour-seeking radiopharmaceuticals; with standard gamma-cameras, is proved of value especially when mammography is indeterminate and in women with dense breasts; nevertheless, this technique shows a high sensitivity only for cancers >1 cm. The issue of detecting small cancers is critical for the future development and clinical usefulness of breast imaging with radiopharmaceuticals, because other modalities are increasingly employed for early identification of small abnormalities. The use of high-resolution dedicated cameras for breast imaging is the best option to improve small cancers' detection: they allow greater flexibility in patient positioning, and the availability of projections similar to those of mammography. Moreover, the detector can be placed directly against the breast, and a mild compression is possible, with the results of reducing breast thickness, increasing the target-to-background ratio and the sensitivity. Our first clinical findings using the dedicased camera Lumagem 3200S (Gamma Medica, Inc., Northridge, USA) are very satisfactory. Till now, 29 patients with BI-RADS category III and IV lesions ≤1 cm were prospectively evaluated using a conventional gamma-camera and the dedicated device. Four out nine (44%) of the malignant lesions were detected with the standard gamma-camera, whereas the high-resolution camera visualized all the breast cancers. The standard gamma-camera and the dedicated one showed the same specificity: 19 out of 20 (95%) benign lesions were negative. Our results indicate that molecular breast imaging with this dedicated camera is able to detect small cancers in patients with probably benign or low-suspicion to indeterminate mammographic findings.  相似文献   

17.
The use of carbon ion beams in cancer therapy (also known as hadron therapy) is steadily growing worldwide; therefore, the demand for more efficient dosimetry systems is also increasing because daily quality assurance (QA) measurements of hadron radiotherapy is one of the most complex and time consuming tasks. The aim of this study is to develop a two-dimensional dosimetry system that offers high spatial resolution, a large field of view, quick data response, and a linear dose–response relationship.We demonstrate the dose imaging performance of a novel digital dose imager using carbon ion beams for hadron therapy. The dose imager is based on a newly-developed gaseous detector, a well-type glass gas electron multiplier. The imager is successfully operated in a hadron therapy facility with clinical intensity beams for radiotherapy. It features a high spatial resolution of less than 1 mm and an almost linear dose–response relationship with no saturation and very low linear-energy-transfer dependence. Experimental results show that the dose imager has the potential to improve dosimetry accuracy for daily QA.  相似文献   

18.
Telepathology which is the diagnostic work of a pathologist at a distance has been developed to routine application within the last ten years. It can be classified in relation to application, technical solutions, or performance conditions. Diagnostic pathology performance distinguishes primary diagnosis (for example, frozen section statement) from secondary diagnosis (for example, expert consultation) and quality assurance (diagnostic accuracy, continuous education and training). Applications comprise (a) frozen section service; (b) expert consultations; (c) remote control measurements; and (d) education and training. The technical solutions distinguish active (remote control, live imaging) systems from passive (conventional microscope handling, static imaging), and the performance systems with interactive (on-line, live imaging) use from those with passive (offline, static imaging) practice. Intra-operative frozen section service is mainly performed with remote control systems; whereas expert consultations and education/training are commonly based upon Internet connections with static imaging in an off-line mode. The image quality, transfer rates, and screen resolution of active and passive telepathology systems are sufficient for an additional or primary judgment of histological slides and cytological smears. From the technical point of view, remote control telepathology requires a fast transfer and at least near on-line judgement of images, i.e., image acquisition, transfer and presentation can be considered one performance function. Thus, image size, line transfer rate and screen resolution define the practicability of the system. In expert consultation, the pixel resolution of images and natural color presentation are the main factors for diagnostic support, whereas the line transfer rate is of minor importance. These conditions define the technical compartments, especially size and resolution of camera and screen. The performance of commercially available systems has reached a high quality standard. Pathologists can be trained in a short time and use the systems in a routine manner. Several telepathology systems have been implemented in large Institutes of Pathology which serve for frozen section diagnosis in small hospitals located in the local area. In contrast, expert consultation is mainly performed with international connections. There is a remarkable increase of expert consultations by telepathology according to the experiences of the Armed Forces Institute of Pathology or the Department of Pathology, Thoraxklinik, Heidelberg. In expansion of these experiences, a "globalization" of telepathology can be expected. Telepathology can be used to shrink the period necessary for final diagnosis by request for diagnostic assistance to colleagues working in appropriate related time zones. Telepathology is, therefore, not a substitute of conventional diagnostic procedures but a real improvement in the world of pathology.  相似文献   

19.
From HO Anger's analogic gamma camera to digital camera, developed countries are at the time of hybrid cameras SPECT/CT and PET/CT. Sub-Saharan black Africa in the image of Côte d’Ivoire, a country with limited medical resources shows an important delay in the evolution of the health system in general and particularly in medical imaging equipment. The purpose of this paper was to approach the issues, challenges and sustainable strategy for the implementation of hybrid imaging SPECT/CT in a developing country where the rate of morbidity and mortality remains high due to infectious but also cancer diseases because of the inadequacy of the health technical platform. To address these challenges, Côte d’Ivoire like many countries in sub-Saharan Africa with limited medical resources must design, test and develop clinical strategies adapted to developing countries. Health authorities of this country must develop a policy for sustainable financing of medical imaging, including the training of the adequate health personnel according to a model of corporate leadership. In this perspective, Côte d’Ivoire must have a SPECT/CT instead of a simple gamma camera. This would allow to optimize its diagnostic health system in oncology, bone and joint disease and in many other medical disciplines. And especially since the SPECT/CT is a high-performance device that has largely demonstrated its diagnostic efficiency and that can be used as SPECT alone or as isolated CT. In addition, this country should take over digital imaging in the context of cooperation with some countries of Africa and Europe ahead in the field of modern medical imaging, seeking assistance from international organizations (IAEA, RAD-AID, WHO,…). Finally this country should implement methods of assessment, types of performance indicators to guide planning for future projects of its system.  相似文献   

20.
Magnetic resonance imaging (MRI) is a widely used method for non-invasive study of the structure and function of the human brain. Increasing magnetic field strengths enable higher resolution imaging; however, long scan times and high motion sensitivity mean that image quality is often limited by the involuntary motion of the subject. Prospective motion correction is a technique that addresses this problem by tracking head motion and continuously updating the imaging pulse sequence, locking the imaging volume position and orientation relative to the moving brain. The accuracy and precision of current MR-compatible tracking systems and navigator methods allows the quantification and correction of large-scale motion, but not the correction of very small involuntary movements in six degrees of freedom. In this work, we present an MR-compatible tracking system comprising a single camera and a single 15 mm marker that provides tracking precision in the order of 10 m and 0.01 degrees. We show preliminary results, which indicate that when used for prospective motion correction, the system enables improvement in image quality at both 3 T and 7 T, even in experienced and cooperative subjects trained to remain motionless during imaging. We also report direct observation and quantification of the mechanical ballistocardiogram (BCG) during simultaneous MR imaging. This is particularly apparent in the head-feet direction, with a peak-to-peak displacement of 140 m.  相似文献   