首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
The role of the intrinsic finger flexor muscles was investigated during finger flexion tasks. A suspension system was used to measure isometric finger forces when the point of force application varied along fingers in a distal-proximal direction. Two biomechanical models, with consideration of extensor mechanism Extensor Mechanism Model (EMM) and without consideration of extensor mechanism Flexor Model (FM), were used to calculate forces of extrinsic and intrinsic finger flexors. When the point of force application was at the distal phalanx, the extrinsic flexor muscles flexor digitorum profundus, FDP, and flexor digitorum superficialis, FDS, accounted for over 80% of the summed force of all flexors, and therefore were the major contributors to the joint flexion at the distal interphalangeal (DIP), proximal interphalangeal (PIP), and metacarpophalangeal (MCP) joints. When the point of force application was at the DIP joint, the FDS accounted for more than 70% of the total force of all flexors, and was the major contributor to the PIP and MCP joint flexion. When the force of application was at the PIP joint, the intrinsic muscle group was the major contributor for MCP flexion, accounting for more than 70% of the combined force of all flexors. The results suggest that the effects of the extensor mechanism on the flexors are relatively small when the location of force application is distal to the PIP joint. When the external force is applied proximally to the PIP joint, the extensor mechanism has large influence on force production of all flexors. The current study provides an experimental protocol and biomechanical models that allow estimation of the effects of extensor mechanism on both the extrinsic and intrinsic flexors in various loading conditions, as well as differentiating the contribution of the intrinsic and extrinsic finger flexors during isometric flexion.  相似文献   

2.
A biomechanical model of a thumb would be useful for exploring the mechanical loadings in the musculoskeletal system, which cannot be measured in vivo. The purpose of the current study is to develop a practical kinematic thumb model using the commercial software Anybody (Anybody Technology, Aalborg, Denmark), which includes real CT-scans of the bony sections and realistic tendon/muscle attachments on the bones. The thumb model consists of a trapezium, a metacarpal bone, a proximal and a distal phalanx. These four bony sections are linked via three joints, i.e., IP (interphalangeal), MP (metacarpophalangeal) and CMC (carpometacarpal) joints. Nine muscles were included in the proposed model. The theoretically calculated moment arms of the tendons are compared with the corresponding experimental data by Smutz et al. [1998. Mechanical advantage of the thumb muscles. J. Biomech. 31(6), 565–570]. The predicted muscle moment arms of the majority of the muscle/tendon units agree well with the experimental data in the entire range of motion. Close to the end of the motion range, the predicted moment arms of several muscles (i.e., ADPt and ADPo (transverse and oblique heads of the adductor pollicis, respectively) muscles for CMC abduction/adduction and ADPt and FPB (flexor pollicis brevis) muscle for MP extension/flexion) deviate from the experimental data. The predicted moment potentials for all muscles are consistent with the experimental data. The findings thus suggest that, in a biomechanical model of the thumb, the mechanical functions of muscle–tendon units with small physiological cross-sectional areas (PCSAs) can be well represented using single strings, while those with large PCSAs (flat-wide attachments, e.g., ADPt and ADPo) can be represented by the averaged excursions of two strings. Our results show that the tendons with large PCSAs can be well represented biomechanically using the proposed approach in the major range of motion.  相似文献   

3.
A novel technique to estimate the contribution of finger extensor tendons to joint moment generation was proposed. Effective static moment arms (ESMAs), which represent the net effects of the tendon force on joint moments in static finger postures, were estimated for the 4 degrees of freedom (DOFs) in the index finger. Specifically, the ESMAs for the five tendons contributing to the finger extensor apparatus were estimated by directly correlating the applied tendon force to the measured resultant joint moments in cadaveric hand specimens. Repeated measures analysis of variance revealed that the finger posture, specifically interphalangeal joint angles, had significant effects on the measured ESMA values in 7 out of 20 conditions (four DOFs for each of the five muscles). Extensor digitorum communis and extensor indicis proprius tendons were found to have greater MCP ESMA values when IP joints are flexed, whereas abduction ESMAs of all muscles except extensor digitorum profundus were mainly affected by MCP flexion. The ESMAs were generally smaller than the moment arms estimated in previous studies that employed kinematic measurement techniques. Tendon force distribution within the extensor hood and dissipation into adjacent structures are believed to contribute to the joint moment reductions, which result in smaller ESMA values.  相似文献   

4.
Estimation of instantaneous moment arms of lower-leg muscles   总被引:2,自引:0,他引:2  
Muscle moment arms at the human knee and ankle were estimated from muscle length changes measured as a function of joint flexion angle in cadaver specimens. Nearly all lower-leg muscles were studied: extensor digitorum longus, extensor hallucis longus, flexor digitorum longus, flexor hallucis longus, gastrocnemius lateralis, gastrocnemius medialis, peroneus brevis, peroneus longus, peroneus tertius, plantaris, soleus, tibialis anterior, and tibialis posterior. Noise in measured muscle length was filtered by means of quintic splines. Moment arms of the mm. gastrocnemii appear to be much more dependent on joint flexion angles than was generally assumed by other investigators. Some consequences for earlier analyses are mentioned.  相似文献   

5.
The role of the forearm (extrinsic) finger flexor muscles in initiating rotation of the metacarpophalangeal (MCP) joint and in coordinating flexion at the MCP, the proximal interphalangeal (PIP), and distal interphalangeal (DIP) joints remains a matter of some debate. To address the biomechanical feasibility of the extrinsic flexors performing these actions, a computer simulation of the index finger was created. The model consisted of a planar open-link chain comprised of three revolute joints and four links, driven by the change in length of the flexor muscles. Passive joint characteristics, included in the model, were obtained from system identification experiments involving the application of angular perturbations to the joint of interest. Simulation results reveal that in the absence of passive joint torque, shortening of the extrinsic flexors results in PIP flexion (80°), but DIP (8°) and MCP (7°) joint extension. The inclusion of normal physiological levels of passive joint torque, however, results in simultaneous flexion of all three joints (63° for DIP, 75° for PIP, and 43° for MCP). Applicability of the simulation results was confirmed by recording finger motion produced by electrical stimulation of the extrinsic flexor muscles for the index finger. These findings support the view that the extrinsic flexor muscles can initiate MCP flexion, and produce simultaneous motion at the MCP, PIP, and DIP joints.  相似文献   

6.
This study examined the effect of computer keyboard keyswitch design on muscle activity patterns during finger tapping. In a repeated-measures laboratory experiment, six participants tapped with their index fingers on five isolated keyswitch designs with varying force–displacement characteristics that provided pairwise comparisons for the design factors of (1) activation force (0.31 N vs. 0.59 N; 0.55 N vs. 0.93 N), (2) key travel (2.5 mm vs. 3.5 mm), and (3) shape of the force–displacement curve as realized through buckling-spring vs. rubber-dome switch designs. A load cell underneath the keyswitch measured vertical fingertip forces, and intramuscular fine wire EMG electrodes measured muscle activity patterns of two intrinsic (first lumbricalis, first dorsal interossei) and three extrinsic (flexor digitorum superficialis, flexor digitorum profundus, and extensor digitorum communis) index finger muscles. The amplitude of muscle activity for the first dorsal interossei increased 25.9% with larger activation forces, but not for the extrinsic muscles. The amplitude of muscle activity for the first lumbricalis and the duration of muscle activities for the first dorsal interossei and both extrinsic flexor muscles decreased up to 40.4% with longer key travel. The amplitude of muscle activity in the first dorsal interossei increased 36.6% and the duration of muscle activity for all muscles, except flexor digitorum profundus, decreased up to 49.1% with the buckling-spring design relative to the rubber-dome design. These findings suggest that simply changing the force–displacement characteristics of a keyswitch changes the dynamic loading of the muscles, especially in the intrinsic muscles, during keyboard work.  相似文献   

7.
A program of controlled motion following repair of flexor tendons in the hand is presented. This regimen incorporates the features of active extension against rubber band passive flexion, as well as those of controlled passive extension and passive flexion. In this prospective study, 44 digits with complete lacerations of the flexor digitorum profundus and flexor digitorum superficialis in zone 2 were treated. Using the Strickland formula of total active motion of the interphalangeal joints, 36 fingers (82 percent) were rated "excellent"; 7 fingers (16 percent) were rated "good"; 1 finger (2 percent) was rated "fair"; none was rated "poor". There was no statistical difference between the results of delayed primary repair and immediate primary repair.  相似文献   

8.
The postoperative outcome of hand flexor tendon repair remains limited by tendon adhesions that prevent normal range of motion. Recent studies using in situ hybridization techniques have implicated transforming growth factor beta-1 (TGF-beta1) in both intrinsic and extrinsic mechanisms of repair. TGF-beta1 is a growth factor that plays multiple roles in wound healing and has also been implicated in the pathogenesis of excessive scar formation. The purpose of this study was to examine the effect of neutralizing antibody to TGF-beta1 in a rabbit zone II flexor tendon wound-healing model. Twenty-two adult New Zealand White rabbits underwent complete transection of the middle digit flexor digitorum profundus tendon in zone II. The tendons were immediately repaired and received intraoperative infiltration of one of the following substances: (1) control phosphate-buffered saline; (2) 50 microg neutralizing antibody to TGF-beta1; (3) 50 microg each of neutralizing antibody to TGF-beta1 and to TGF-beta2. Eight rabbits that had not been operated on underwent analysis for determination of normal flexion range of motion at their proximal and distal interphalangeal joints, using a 1.2-N axial load applied to the flexor digitorum profundus tendon. All rabbits that had been operated on were placed in casts for 8 weeks to allow maximal tendon adhesion and were then killed to determine their flexion range of motion. Statistical analysis was performed using the Student's unpaired t test. When a 1.2-N load was used on rabbit forepaws that had not been operated on, normal combined flexion range of motion at the proximal and distal interphalangeal joints was 93+/-6 degrees. Previous immobilization in casts did not reduce the range of motion in these forepaws (93+/-4 degrees). In the experimental groups, complete transection and repair of the flexor digitorum profundus tendon with infiltration of control phosphate-buffered saline solution resulted in significantly decreased range of motion between the proximal and distal phalanges [15+/-6 degrees (n = 8)]. However, in the tendon repairs infiltrated with neutralizing antibody to TGF-beta1, flexion range of motion increased to 32+/-9 degrees (n = 7; p = 0.002). Interestingly, a combination of neutralizing antibody to TGF-beta1 and that to TGF-beta2 did not improve postoperative range of motion [18+/-4 degrees (n = 7; p = 0.234)]. These data demonstrate that (1) the rabbit flexor tendon repair model is useful for quantifying tendon scar formation on the basis of degrees of flexion between proximal and distal phalanges; (2) intraoperative infiltration of neutralizing antibody to TGF-beta1 improves flexor tendon excursion; and (3) simultaneous infiltration of neutralizing antibody to TGF-beta2 nullifies this effect. Because TGF-beta1 is thought to contribute to the pathogenesis of excessive scar formation, the findings presented here suggest that intraoperative biochemical modulation of TGF-beta1 levels limits flexor tendon adhesion formation.  相似文献   

9.
LEARNING OBJECTIVES: After reviewing the article, the participant should be able to: (1) Describe the anatomy of the extensor tendons at the level of the forearm, wrist, hand, and fingers. (2) Recognize variations in the anatomy. (3) Master the hand examination and define the relevant findings in acute injuries of the extensor tendon(s). (4) Delineate the techniques for extensor repair in both acute and secondary (delayed) management. SUMMARY: Extension of the fingers is an intricate process that reflects the combined action of two independent systems. The interossei and lumbricals constitute the intrinsic musculature of the hand. These muscles innervated by the median and ulnar nerves extend the proximal interphalangeal and distal interphalangeal joints and flex the metacarpophalangeal joints. The extrinsic extensors are a group of muscles innervated by the radial nerve, originating proximal to the forearm. The extrinsic digital extensor muscles include the extensor digitorum communis, extensor indicis proprius, and extensor digiti quinti. The digital extensors function primarily to extend the metacarpophalangeal joints, but also extend the proximal interphalangeal and distal interphalangeal joints. Normal extensor physiology reflects a delicate balance between these two unique extensor systems. In the injured hand, a functioning intrinsic system may potentially compensate for an extrinsic deficit. An understanding of the relevant anatomy and an appreciation for the complex interplay involved in extensor physiology is necessary to recognize and manage these injuries.  相似文献   

10.
The present work displayed the first quantitative data of forces acting on tendons and pulleys during specific sport-climbing grip techniques. A three-dimensional static biomechanical model was used to estimate finger muscle tendon and pulley forces during the "slope" and the "crimp" grip. In the slope grip the finger joints are flexed, and in the crimp grip the distal interphalangeal (DIP) joint is hyperextended while the other joints are flexed. The tendons of the flexor digitorum profundus and superficialis (FDP and FDS), the extensor digitorum communis (EDC), the ulnar and radial interosseus (UI and RI), the lumbrical muscle (LU) and two annular pulleys (A2 and A4) were considered in the model. For the crimp grip in equilibrium conditions, a passive moment for the DIP joint was taken into account in the biomechanical model. This moment was quantified by relating the FDP intramuscular electromyogram (EMG) to the DIP joint external moment. Its intensity was estimated at a quarter of the external moment. The involvement of this parameter in the moment equilibrium equation for the DIP joint is thus essential. The FDP-to-FDS tendon-force ratio was 1.75:1 in the crimp grip and 0.88:1 in the slope grip. This result showed that the FDP was the prime finger flexor in the crimp grip, whereas the tendon tensions were equally distributed between the FDP and FDS tendons in the slope grip. The forces acting on the pulleys were 36 times lower for A2 in the slope grip than in the crimp grip, while the forces acting on A4 were 4 times lower. This current work provides both an experimental procedure and a biomechanical model that allows estimation of tendon tensions and pulley forces crucial for the knowledge about finger injuries in sport climbing.  相似文献   

11.
The human finger contains tendon/ligament mechanisms essential for proper control. One mechanism couples the movements of the interphalangeal joints when the (unloaded) finger is flexed with active deep flexor. This study’s aim was to accurately determine in a large finger sample the kinematics and variability of the coupled interphalangeal joint motions, for potential clinical and finger model validation applications. The data could also be applied to humanoid robotic hands. Sixty-eight fingers were measured in seventeen hands in nine subjects. Fingers exhibited great joint mobility variability, with passive proximal interphalangeal hyperextension ranging from zero to almost fifty degrees. Increased measurement accuracy was obtained by using marker frames to amplify finger segment motions. Gravitational forces on the marker frames were not found to invalidate measurements. The recorded interphalangeal joint trajectories were highly consistent, demonstrating the underlying coupling mechanism. The increased accuracy and large sample size allowed for evaluation of detailed trajectory variability, systematic differences between flexion and extension trajectories, and three trigger types, distinct from flexor tendon triggers, involving initial flexion deficits in either proximal or distal interphalangeal joint. The experimental methods, data and analysis should advance insight into normal and pathological finger biomechanics (e.g., swanneck deformities), and could help improve clinical differential diagnostics of trigger finger causes. The marker frame measuring method may be useful to quantify interphalangeal joints trajectories in surgical/rehabilitative outcome studies. The data as a whole provide the most comprehensive collection of interphalangeal joint trajectories for clinical reference and model validation known to us to date.  相似文献   

12.
13.
The intrinsic and extrinsic muscles are considered to stabilize the foot and contribute to propulsion during walking. This study aimed to clarify the functional relationship between intrinsic and extrinsic muscles during walking. Thirteen healthy men participated in this study. The muscle activities of the intrinsic muscles (quadratus plantae and abductor hallucis), and the extrinsic muscles (flexor hallucis longus, flexor digitorum longus, and tibialis posterior) were measured using fine-wire and surface electromyography during walking. The muscle onset timing after foot contact was calculated and compared among muscles using the one-way ANOVA. The stance phase was divided into early and late braking, and early and late propulsion phases. Muscle activity among phases was compared using repeated-measures ANOVA. The onset time of the abductor hallucis was significantly earlier than those of the flexor digitorum longus and tibialis posterior. The quadratus plantae demonstrated significantly earlier onset than that of the tibialis posterior. In the late propulsion phase, the activity of extrinsic muscles decreased, whereas intrinsic muscles were continuously active. Early activation of the intrinsic muscles may stabilize the foot for efficient torque production by the extrinsic muscles. Furthermore, the intrinsic muscles may contribute to the final push-off after the deactivation of extrinsic muscles.  相似文献   

14.
A detailed musculoskeletal model of the human hand is needed to investigate the pathomechanics of tendon disorders and carpal tunnel syndrome. The purpose of this study was to develop a biomechanical model with realistic flexor tendon excursions and moment arms. An existing upper extremity model served as a starting point, which included programmed movement of the index finger. Movement capabilities were added for the other fingers. Metacarpophalangeal articulations were modelled as universal joints to simulate flexion/extension and abduction/adduction while interphalangeal articulations used hinges to represent flexion. Flexor tendon paths were modelled using two approaches. The first method constrained tendons with control points, representing annular pulleys. The second technique used wrap objects at the joints as tendon constraints. Both control point and joint wrap models were iteratively adjusted to coincide with tendon excursions and moment arms from a anthropometric regression model using inputs for a 50th percentile male. Tendon excursions from the joint wrap method best matched the regression model even though anatomic features of the tendon paths were not preserved (absolute differences: mean<0.33 mm, peak<0.74 mm). The joint wrap model also produced similar moment arms to the regression (absolute differences: mean<0.63 mm, peak<1.58 mm). When a scaling algorithm was used to test anthropometrics, the scaled joint wrap models better matched the regression than the scaled control point models. Detailed patient-specific anatomical data will improve model outcomes for clinical use; however, population studies may benefit from simplified geometry, especially with anthropometric scaling.  相似文献   

15.
Subject-specific musculoskeletal models require accurate values of muscle moment arms. The aim of this study was to compare moment arms of wrist tendons obtained from non-invasive magnetic resonance imaging (MRI) to those obtained from an in vitro experimental approach. MRI was performed on ten upper limb cadaveric specimens to obtain the centrelines for the flexor carpi radialis (FCR), flexor carpi ulnaris (FCU), extensor carpi radialis longus (ECRL), extensor carpi radialis brevis (ECRB), extensor carpi ulnaris (ECU), and abductor pollicis longus (APL) tendons. From these, the anatomical moment arms about each of the flexion-extension (FE) and radioulnar deviation (RUD) axes of the wrist were calculated. Specimens were mounted on a physiologic wrist simulator to obtain functional measurements of the moment arms using the tendon excursion method. No differences were observed between anatomical and functional values of the FE and RUD moment arms of FCR, ECRL and ECRB, and the RUD moment arm of ECU (p > .075). Scaling the anatomical moment arms relative to ECRB in FE and ECU in RUD reduced differences in the FE moment arm of FCU and the RUD moment arm of APL to less than 15% (p > .139). However, differences persisted in moment arms of FCU in RUD, and ECU and APL in FE (p < .008). This study shows that while measurements of moment arms of wrist tendons using imaging do not always conform to values obtained using in vitro experimental approaches, a stricter protocol could result in the acquisition of subject-specific moment arms to personalise musculoskeletal models.  相似文献   

16.
Abstract

To improve our understanding on the neuromechanics of finger movements, a comprehensive musculoskeletal model is needed. The aim of this study was to build a musculoskeletal model of the hand and wrist, based on one consistent data set of the relevant anatomical parameters. We built and tested a model including the hand and wrist segments, as well as the muscles of the forearm and hand in OpenSim. In total, the model comprises 19 segments (with the carpal bones modeled as one segment) with 23 degrees of freedom and 43 muscles. All required anatomical input data, including bone masses and inertias, joint axis positions and orientations as well as muscle morphological parameters (i.e. PCSA, mass, optimal fiber length and tendon length) were obtained from one cadaver of which the data set was recently published. Model validity was investigated by first comparing computed muscle moment arms at the index finger metacarpophalangeal (MCP) joint and wrist joint to published reference values. Secondly, the muscle forces during pinching were computed using static optimization and compared to previously measured intraoperative reference values. Computed and measured moment arms of muscles at both index MCP and wrist showed high correlation coefficients (r?=?0.88 averaged across all muscles) and modest root mean square deviation (RMSD?=?23% averaged across all muscles). Computed extrinsic flexor forces of the index finger during index pinch task were within one standard deviation of previously measured in-vivo tendon forces. These results provide an indication of model validity for use in estimating muscle forces during static tasks.  相似文献   

17.
A 7-year-old girl who was unable to flex her left thumb at the interphalangeal joint proved to have an extremely hypoplastic flexor pollicis longus with normal thenar muscles, which is very rare. The flexor digitorum superficialis of the ring finger was transferred to the inserting portion of the flexor pollicis longus tendon with good results. The patient's cooperation seems to be a factor determining the prognosis.  相似文献   

18.
Previous deterministic finger biomechanical models predicted that the flexor digitorum superficialis (FDS) was silent and the flexor digitorum profundus (FDP) was the only active flexor during finger flexion. Experimental studies in vivo, however, recorded activities of both flexors. In this study, in an attempt to elucidate the roles of the flexors, a probabilistic biodynamic model of the index finger was constructed to estimate the muscle–tendon forces during an experimentally measured index finger flexion movement.A Monte-Carlo simulation was performed with four model parameters, including moment arms, physiological cross sectional areas (PCSA), passive torques, and anthropometric measures as independent random variables. The muscle-tendon forces at each time point were determined using a nonlinear optimization technique. The model predicted that both FDS and FDP contributed to sustaining the movement and the FDS was not necessarily silent. The two distinct force patterns observed in vivo in experimental studies were also corroborated by the simulation. These findings, contrary to previous deterministic models’ predictions but in agreement with experimental measurements, explained the observed coactivation of FDS and FDP, and resolved the controversy regarding the roles of the flexors in finger movement dynamics.  相似文献   

19.
The microsurgical second toe wrap-around technique is an ideal treatment option for reconstruction of the distal half of the finger with circumferential loss of skin and nail associated with an uninjured proximal interphalangeal joint and an intact insertion of the flexor digitorum superficialis tendon. Follow-up of 13 flaps in 10 patients from 1986 to 1989 demonstrates rapid and adequate functional recovery as well as satisfactory aesthetic appearance in all patients.  相似文献   

20.
A mathematical model proposed by Hume et al., 1991. Journal of Hand Surgery-American Volume 16, 722-730 for the determination of the forces acting on the A2 and A4 pulley was used. The parameters necessary for this determination include the angle of flexion, the positioning of the pulley with respect to the centre of rotation in the proximal interphalangeal joint (PIP), the relative mismatch between bone and tendon width at the location of the respective pulleys as well as the tendon height at this position. This model was further developed to include the stiffness of the respective pulley, as well as the fact, that there are two flexor tendons of which only one passes through both pulleys. Each parameter was then evaluated using a sensitivity analysis proposed by Fasham et al., 1990. Journal of Marine Research 48, 591-639 in order to determine their relative importance for the outcome of the model. The most important parameter proofed to be the positioning of the pulley with respect to the centre of rotation in the PIP joint. This observation enabled us to give the best possible placement for a pulley graft after pulley rupture.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号