首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Manumycin A is a natural antibiotic produced by Streptomyces parvulus that has antineoplastic activity against a variety of human cancers in nude mouse models. We have developed a highly sensitive reverse phase high-performance liquid chromatography (HPLC) method based on ultraviolet (UV) detection for the determination of manumycin A in mouse plasma. Manumycin A was isolated from mouse plasma by solid-phase extraction. A gradient elution of methanol and 0.05 M H(3)PO(4) with 0.2% triethylamine mobile phase was employed and separation was achieved with a C(18) analytical column. Manumycin A was detected by UV absorption at 345 nm. Retention time for manumycin A was 8.9+/-0.2 min. The manumycin A peak was baseline resolved, with the nearest peak at 1.5 min distance and no interfering peaks detected. Inter- and intra-day coefficients of variance were less than 6.1 and 5.1%, respectively. Based on an extracted manumycin A standard plasma sample of 0.25 microg/ml, the assay precision was 99.8% with a mean accuracy of 95.1%. At plasma concentrations of 0.5 and 5 microg/ml, the mean recovery rates of manumycin A were 59.64 and 60.28%, respectively. The lower limit of detection (LLD) for manumycin A was 0.1 microg/ml in mouse plasma. The lower limit of quantification (LLQ) for manumycin A was 0.125 microg/ml. Results of the stability study indicated that when frozen at -80 degrees C, manumycin A was stable in mouse plasma for up to 2 weeks. This method is useful in quantification of manumycin A in mouse plasma for clinical pharmacology studies in mice.  相似文献   

2.
Karenitecin is a novel, highly lipophilic camptothecin derivative with potent anticancer potential. We have developed a sensitive high-performance liquid chromatographic method for the determination of karenitecin concentration in human plasma and urine. Karenitecin was isolated from human plasma and urine using solid-phase extraction. Separation was achieved by gradient elution, using a water and acetonitrile mobile phase, on an ODS analytical column. Karenitecin was detected using fluorescence detection at excitation and emission wavelengths of 370 and 490 nm, respectively. Retention time for karenitecin was 16.2±0.5 min and 8.0±0.2 min for camptothecin, the internal standard. The karenitecin peak was baseline resolved, with the nearest peak at 3.1 min distance. Using normal volunteer plasma and urine from multiple individuals, as well as samples from the 50 patients analyzed to date, no interfering peaks were detected. Inter- and intra-day coefficients of variance were <4.4 and 7.1% for plasma and <4.9 and 11.6% for urine. Assay precision, based on an extracted karenitecin standard plasma sample of 2.5 ng/ml, was +4.46% with a mean accuracy of 92.4%. For extracted karenitecin standard urine samples of 2.5 ng/ml assay precision was +2.35% with a mean accuracy of 99.5%. The mean recovery of karenitecin, at plasma concentrations of 1.0 and 50 ng/ml, was 81.9 and 87.8% respectively. In urine, at concentrations of 1.5 and 50 ng/ml, the mean recoveries were 90.3 and 78.4% respectively. The lower limit of detection (LLD) for karenitecin was 0.5 ng/ml in plasma and 1.0 ng/ml in urine. The lower limit of quantification (LLQ) for karenitecin was 1 ng/ml and 1.5 ng/ml for plasma and urine, respectively. Stability studies indicate that when frozen at −70°C, karenitecin is stable in human plasma for up to 3 months and in human urine for up to 1 month. This method is useful for the quantification of karenitecin in plasma and urine samples for clinical pharmacology studies in patients receiving this agent in clinical trials.  相似文献   

3.
Current compendial (USP) methods of assay for the analysis of biperiden in bulk form and pharmaceutical dosage forms involve the use of titrimetric and spectrophotometric procedures, respectively. These are non-selective and non-stability-indicating techniques. In this work, a stability-indicating high performance liquid chromatographic assay procedure has been developed and validated for biperiden. The liquid chromatographic separation was achieved isocratically on a symmetry C8 column (150 mm x 3.9 mm i.d., 5 microm particle size) using a mobile phase containing methanol-buffer (50:50, v/v, pH 2.50) at a flow rate of 1 ml/min and UV detection at 205 nm. The buffer was composed of sodium dihydrogen phosphate (50 mM) and 1-heptanesulfonic acid sodium salt (5 mM). The method was linear over the concentration range of 0.5-25 microg/ml (r=0.9998) with a limit of detection and quantitation 0.03 and 0.1 microg/ml, respectively. The method has the requisite accuracy, selectivity, sensitivity and precision to assay biperiden in bulk form and pharmaceutical dosage forms. Degradation products resulting from the stress studies did not interfere with the detection of biperiden and the assay is thus stability-indicating.  相似文献   

4.
A sensitive assay for the determination of unbound ertapenem in human plasma and bronchoalveolar lavage (BAL) was developed using ultrafiltration of plasma and BAL samples. A rapid HPLC method was used with ultraviolet detection set at a wavelength of 305 nm and a separation on a Prontosil AQ C18 column, with imipenem used as internal standard. This assay was linear over the concentration range of 0.5-100 microg/mL and 0.25-50 microg/mL in plasma and BAL, respectively. Limits of detection and quantitation were respectively 0.05 and 0.25 microg/mL. Validation data for accuracy and precision were CV<2.48 and 8.25%, accuracy in the range 98.1-104.2% and 102.2-108.4%, respectively, for intra and inter-day.  相似文献   

5.
A simple method for the measurement of the active leflunomide metabolite A77 1726 in human plasma by HPLC is presented. The sample workup was simple, using acetonitrile for protein precipitation. Chromatographic separation of A77 1726 and the internal standard, alpha-phenylcinnamic acid, was achieved using a C(18) column with UV detection at 305 nm. The assay displayed reproducible linearity for A77 1726 with determination coefficients (r2) > 0.997 over the concentration range 0.5-60.0 microg/ml. The reproducibility (%CV) for intra- and inter-day assays of spiked controls was <5%. The limit of quantification was 0.8 microg/ml. The average absolute recovery was approximately 100%. This assay is suitable for the determination of A77 1726 in plasma of patients taking leflunomide, and is simpler to use than other HPLC methods reported previously.  相似文献   

6.
Hydroxyurea is an antitumor drug widely used in the treatment of sickle cell disease. The drug has been analyzed in biological fluids by a number of high-performance liquid chromatography (HPLC) methods. This paper describes a fast and highly reliable capillary gas chromatography-mass spectrometry (GC-MS) procedure that was developed for the detection and quantitation of hydroxyurea in plasma. The compound and its labeled internal standard were liquid extracted from plasma and derivatized with BSTFA before analysis. The detection limit of the assay was 0.078 microg/ml and the limit of quantitation was 0.313 microg/ml with linearity up to 500 microg/ml. Intra-day variation, as coefficient of variation (C.V., %) over the selected concentration range, was 0.3-8.7% and inter-day variation was 0.4-9.6%.  相似文献   

7.
A stereoselective reversed-phase HPLC assay to determine S-(-) and R-(+) enantiomers of esmolol in human plasma was developed. The method involved liquid-liquid extraction of esmolol from human plasma, using S-(-)-propranolol as the internal standard, and employed 2,3,4,6-tetra-O-acetyl-beta-d-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The derivatized products were separated on a 5-microm reversed-phase C18 column with a mixture of acetonitrile/0.02 mol/L phosphate buffer (pH 4.5) (55:45, v/v) as mobile phase. The detection of esmolol derivatives was made at lambda=224 nm with UV detector. The assay was linear from 0.035 to 12 microg/ml for each enantiomer. The analytical method afforded average recoveries of 94.8% and 95.5% for S-(-)- and R-(+)-esmolol, respectively. For each enantiomer, the limit of detection was 0.003 microg/ml and the limit of quantification for the method was 0.035 microg/ml (RSD<14%). The reproducibility of the assay was satisfactory.  相似文献   

8.
A reversed-phase high-performance liquid chromatographic method using a mobile phase of acetonitrile-methanol-trifluoroacetic acid-water (16.1:7.2:0.1:76.6, v/v/v/v) at a flow rate of 1.0 ml min(-1) on a LiChrospher RP-18 column with UV (254 nm) detection has been developed for the separation of sulfadoxine and its metabolite N-acetyl sulfadoxine in plasma. No interferences due to endogenous compounds or common antimalarial drugs were noticed. The limit of detection for sulfadoxine and N-acetyl sulfadoxine was 0.01 microg ml(-1) with a signal-to-noise ratio of 5:1 while the limit of quantification was 2.5 microg ml(-1). Intra-day mean relative standard deviations (RSD's) for sulfadoxine and N-acetyl sulfadoxine were 2.6 and 2.8%, respectively, while mean inter-day RSD's for sulfadoxine and N-acetyl sulfadoxine were 2.4 and 2.8%, respectively. Extraction recoveries averaged 90.6% for sulfadoxine and 86.9% for N-acetyl sulfadoxine. The method was applied for the assay of sulfadoxine and its metabolite N-acetyl sulfadoxine in plasma from Plasmodium falciparum malaria patients. Mean plasma sulfadoxine concentrations on day 2 (51 h) from samples collected from sensitive and resistant P. falciparum patients treated with three tablets of Fansidar were 62.8 and 60.5 microg ml(-1), respectively. Mean ratio of N-acetyl sulfadoxine to sulfadoxine was 9.1% for responders and 13.9% for non-responders which revealed that higher amounts of the metabolite N-acetyl sulfadoxine were present in non-responders. The method described should find an application in the therapeutic monitoring of malaria patients.  相似文献   

9.
A reversed-phase HPLC assay has been developed to determine the concentration of the anti-metabolite 2',2'-difluorodeoxycytidine (gemcitabine, dFdC) in human plasma over the concentration range of 0.5-150 microM (0.13-39.44 microg/ml), and 2',2'-difluorodeoxyuridine (dFdU), the deaminated, inactive metabolite, over the range of 1.0-227 microM (0.26-60 microg/ml). After the addition of 20 nmol 2'-fluorodeoxycytidine (FdC) as an internal standard, 0.5-ml samples of plasma were subjected to acetonitrile precipitation, followed by analysis using a gradient reversed-phase HPLC assay with UV detection. A Phenomenex Columbus C(18) column, 5 microm, 150 x 4.6 mm, and a Waters C(18), 4 microm, Nova-Pak Sentry guard column were used to achieve separation. FdC, dFdC and dFdU were monitored at 282, 269 and 258 nm, respectively, on a Waters 996 photodiode array detector. The mobile phase, run at a total flow-rate of 1.5 ml/min, was composed of two solvents: 50 mM ammonium acetate pH 5.0 in either 2% (solvent A) or 10% methanol (solvent B, v/v); 100% solvent A was run for 17 min, followed by a linear gradient to 100% solvent B over 14 min. FdC, dFdC and dFdU were resolved from endogenous compounds and had retention times of 13.6+/-0.5, 18.1+/-1.1 and 29.0+/-0.6 min, respectively. The assay was useful in measuring the plasma levels of both analytes in samples obtained from adult cancer patients participating in a Phase I trial of gemcitabine given as either a 1- or 2-h infusion weekly for 3 of 4 weeks.  相似文献   

10.
A high-performance liquid chromatography (HPLC) method was developed to measure levels of d-threo-1-phenyl-2-palmitoylamino-3-morpholino-1-propanol (d-threo-PPMP) in mouse plasma and liver. d-threo-PPMP was measured by HPLC with a Luna Pheny-Hexyl column (5 microm, 250 mm x 4.6 mm) employing UV detection at 210 nm using a mobile phase of potassium phosphate buffer (20mM, pH 3.0)-acetonitrile in a 45:55 (v/v) ratio. d-threo-1-phenyl-2-pentadecanoylamino-3-morpholino-1-propanol (PC15MP) was employed as an internal standard (IS). The lower limit of quantitation (LLOQ) was 0.3 microg/ml. The assay was linear over a concentration range of 0.3-10 microg/ml, with acceptable precision and accuracy. Assayed in plasma, the intra- and inter-day validation for all coefficients of variation (R.S.D.%) were found less than 15%. The method was applied to samples from athymic (nu/nu) mice treated with d-threo-PPMP by intraperitoneal injection. d-threo-PPMP levels of approximately 10-20 microg/ml ( approximately 20-40 microM) in plasma and approximately 45 microg/g in liver were obtained. The present method can be used to quantify d-threo-PPMP in mice for bioavailability and dose-response studies.  相似文献   

11.
A molecularly imprinted solid-phase extraction coupled with high performance liquid chromatography (MISPE-HPLC) method was developed for rapid screening of mycophenolic acid (MPA) in human plasma. MPA imprinted polymers (MPA-MIP) were synthesized and then tested for their performance both in organic and in aqueous solution. MPA was selectively trapped and preconcentrated on the MPA-MIP sorbent using different loading and washing conditions. The good selectivity of MPA-MIP enabled further clean-up of the interfering components in human plasma. For the proposed MISPE-HPLC method, the linearity between responses (peak area) and concentration was found over the range of 1-100microg/ml with a linear regression coefficient (R(2)) of 0.9989. The limit of detection (LOD) and theoretical limit of quantification (LOQ) for MPA in plasma were 0.10 and 0.32microg/ml, respectively. The precisions were 7.3, 3.5 and 4.7% RSD for intra-day assay and 9.2, 4.1 and 5.5% RSD for inter-day reproducibility, respectively, at three concentration levels of MPA in spiked plasma (1, 10 and 100microg/ml). Both recoveries for the extraction (more than 74%) and for the analytical method (more than 87%) were acceptable for screening MPA in plasma samples. Twelve-hour pharmacokinetic profile of MPA for a renal transplant recipient receiving chronic oral dosing of 500mg mycophenolate mofetil (MMF) was investigated. Results indicated that this method could be applied for therapeutic drug monitoring of mycophenolic acid in patient plasma.  相似文献   

12.
A novel sensor system equipped with a reactor packed with beads containing immobilized beta-1,3-glucanase and glucose oxidase was developed for the amperometric determination of laminarin concentration. The proposed sensor system consisted of a reactor, an oxygen electrode, a flow cell, a pump, a buffer tank, and a recorder. The measurement was performed with a flow injection system. The optimum conditions for the sensor system were as follows: transfer solution, pH 7.0; 0.1 M phosphate buffer solution; flow rate, 0.15 ml/min; and sample volume, 50 microl. The response was correlated to the laminarin concentration. The calibration curve was obtained between 50 and 0.5 mg/ml laminarin (R2 = 0.994). The detection limit was 50 microg/ml laminarin (the ratio of signal/noise = 3). The relative standard deviations were 2.0% (n = 15) and 2.5% (n = 15) for 0.4 and 1.0 mg/ml laminarin solutions, respectively. One assay was completed within 5 min. Results suggest that the sensor can be used not only for the analysis of seaweed and health-enhancing foods but also for monitoring the initial pollution of the marine environment.  相似文献   

13.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10-μm μBondapak phenyl column with an eluting solvent of water—methanol—1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(d-(-)-α-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 ± 6.3% (S.D.) in the concentration ranges of 0.1–20 μg per 0.2 ml of plasma with a limit of detection equivalent to 0.5 μg/ml plasma. The urine assay was validated over a concentration range of 0.025–5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 μg/ml) using a 0.1-ml urine specimen per assay.The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples.  相似文献   

14.
The combination of two sensitive, selective and reproducible reversed phase liquid chromatographic (RP-HPLC) methods was developed for the determination of artesunate (AS), its active metabolite dihydroartemisinin (DHA) and mefloquine (MQ) in human plasma. Solid phase extraction (SPE) of the plasma samples was carried out on Supelclean LC-18 extraction cartridges. Chromatographic separation of AS, DHA and the internal standard, artemisinin (QHS) was obtained on a Hypersil C4 column with mobile phase consisting of acetonitrile-0.05 M acetic acid adjusted to pH 5.2 with 1.0M NaOH (42:58, v/v) at the flow rate of 1.50 ml/min. The analytes were detected using an electrochemical detector operating in the reductive mode. Chromatography of MQ and the internal standard, chlorpromazine hydrochloride (CPM) was carried out on an Inertsil C8-3 column using methanol-acetonitrile-0.05 M potassium dihydrogen phosphate adjusted to pH 3.9 with 0.5% orthophosphoric acid (50:8:42, v/v/v) at a flow rate of 1.00 ml/min with ultraviolet detection at 284 nm. The mean recoveries of AS and DHA over a concentration range of 30-750 ng/0.5 ml plasma and MQ over a concentration of 75-1500 ng/0.5 ml plasma were above 80% and the accuracy ranged from 91.1 to 103.5%. The within-day coefficients of variation were 1.0-1.4% for AS, 0.4-3.4% for DHA and 0.7-1.5% for MQ. The day-to-day coefficients of variation were 1.3-7.6%, 1.8-7.8% and 2.0-3.4%, respectively. Both the lower limit of quantifications for AS and DHA were at 10 ng/0.5 ml and the lower limit of quantification for MQ was at 25 ng/0.5 ml. The limit of detections were 4 ng/0.5 ml for AS and DHA and 15 ng/0.5 ml for MQ. The method was found to be suitable for use in clinical pharmacological studies.  相似文献   

15.
A stereoselective liquid chromatography-tandem mass spectrometry assay was developed and validated for quantification of S- and R-metoprolol at concentrations of 0.5-50 microg/L in human plasma. Metoprolol was extracted from plasma by liquid-liquid extraction with ethyl acetate (82% recovery). Chromatographic separation of the enantiomers was achieved on a chiral Chirobiotic T column using an isocratic mobile phase consisting of methanol/acetic acid/ammonia (100/0.15/0.15, v/v/v). An ion trap mass spectrometer with an electrospray interface was used for detection in the positive mode, monitoring the m/z transition 268-->191 for metoprolol. Standard curves for S- and R-metoprolol fitted quadratic functions (r(2)>or=0.9995) over the range 0.5-50 microg/L in plasma, with 0.5 microg/L representing the limit of quantification. In this range, relative standard deviations were <6% for intra-day precision and <10% for inter-day precision. The accuracy was within the range of 92-105%.  相似文献   

16.
A sensitive chromatographic assay has been developed for m-iodobenzylguanidine (MIBG) in human plasma based on the derivatization with benzoin. MIBG is first isolated from plasma using solid-phase extraction on a cyanopropyl-modified silica phase. After evaporation of the eluate, a fluorescent derivative is formed using benzoin. The derivative is analysed by reversed-phase liquid chromatography using a mixture 60% (v/v) acetonitrile, 30% (v/v) water and 10% (v/v) of the 0.5 M Tris buffer (pH 8.0) as the eluent and fluorescence detection at 320 nm for excitation and 435 nm for emission, respectively. In the evaluated concentration range (2–200 ng/ml) precisions 10% and accuracies in between 90 and 100% have been found, with 2 ng/ml being the lower limit of quantification using a 0.5-ml plasma sample volume. The assay can also be used without the internal standard benzylguanidine. The assay was successfully used to obtain a pharmacokinetic curve of MIBG.  相似文献   

17.
An isocratic and sensitive HPLC assay was developed allowing the determination of the new anticancer drug nilotinib (AMN107) in human plasma, urine, culture medium and cell samples. After protein precipitation with perchloric acid, AMN107 underwent an online enrichment using a Zirchrom-PBD precolumn, was separated on a Macherey-Nagel C18-HD column and finally quantified by UV-detection at 258 nm. The total run time is 25 min. The assay demonstrates linearity within a concentration range of 0.005-5.0 microg/ml in plasma (r(2)=0.9998) and 0.1-10.0 microg/ml in urine (r(2)=0.9913). The intra-day precision expressed as coefficients of variation ranged depending on the spiked concentration between 1.27-9.23% in plasma and 1.77-3.29% in urine, respectively. The coefficients of variation of inter-day precision was lower than 10%. Limit of detection was 0.002 microg/ml in plasma and 0.01 microg/ml in urine. The described method is stable, simple, economic and is routinely used for in vivo and in vitro pharmacokinetic studies of AMN107.  相似文献   

18.
A sensitive HPLC method has been developed for the assay of imatinib in human plasma, by off-line solid-phase extraction followed by HPLC coupled with UV-Diode Array Detection. Plasma (750 microl), with clozapine added as internal standard, is diluted 3 + 1 with water and subjected to a solid-phase extraction on a C18 cartridge. After matrix components elimination with 2000 microl of water (in two aliquots of 1000 microl), imatinib is eluted with 3 x 500 microl MeOH. The resulting eluate is evaporated under nitrogen at room temperature and is reconstituted in 180 microl 50% methanol. A 50 microl volume is injected onto a Nucleosil 100-5 microm C18 AB column. Imatinib is analyzed using a gradient elution program with solvent mixture constituted of methanol and water containing both 0.05% ammonium acetate. Imatinib is detected by UV at 261 nm. The calibration curves are linear between 0.1 and 10 microg/ml. The limit of quantification and detection are 0.05 and 0.01 microg/ml, respectively. The mean absolute recovery of imatinib is 96%. The method is precise with mean inter-day CVs within 1.1-2.4%, and accurate (range of inter-day deviations -0.6 to +0.7%). The method has been validated and is currently being applied in a clinical study assessing the imatinib plasma concentration variability in a population of chronic myeloid leukemia- and gastro-intestinal stromal tumor-patients.  相似文献   

19.
We present a specific method for the determination of disodium clodronate in human plasma and urine using a gas-chromatographic system with nitrogen phosphorus detector (NPD). The compound was extracted from plasma and urine samples by an anion-exchange resin and derivatizated with bistrimethylsilyltrifluoroacetamide (BSTFA). Sodium bromobisphosphonate was used as internal standard. The calibration curves were linear in both plasma and urine, with a regression coefficient r > 0.9975 in plasma and r > 0.9977 in urine.The limit of quantitation was 0.3 microg/ml in plasma and 0.5 microg/ml in urine. The method was validated by intra-day assays at three concentration levels. During the study we carried out inter-day assays to confirm the feasibility of the method. The precision in plasma at 0.5, 15, and 45 microg/ml was 12.4, 0.2, and 6.5% (n = 40), respectively; in urine at 0.8, 8, and 40 microg/ml it was 8.6, 6.4, and 9.3% (n = 40), respectively.The method was accurate and reproducible, and was successfully applied to determine the pharmacokinetic parameters of clodronate in healthy volunteers after intravenous infusion and intramuscular injection of 200 mg of the compound. The Cmax after intravenous infusion and intramuscular injection was 16.1 and 12.8 microg/ml, respectively. AUC(0-48 h) after infusion administration and intramuscular injection was 44.2 +/- 18.0 and 47.5 +/- 12.4 h microg/ml, respectively. The elimination half-life in both administrations was 6.31 +/- 2.7 h.  相似文献   

20.
We developed and validated a simple high-performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection system for determining penciclovir (active metabolite of famciclovir) levels in human plasma using acyclovir as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode by monitoring the transitions: m/z 254.00>152.09 for penciclovir and m/z 226.00>152.09 for IS. The analytes were chromatographed on a Capcellpak MGII C(18) reversed-phase chromatographic column by isocratic elution using 30% methanol and 70% Milli-Q water containing 10 mM ammonium formate (adjusted to pH 3.1 with formic acid). Results were linear over the studied range (0.05-10 microg/ml) with r(2)=0.9999, and the total analysis time for each run was 2 min. Intra- and inter-assay precisions were 2.3-7.8 and 3.7-7.5%, respectively, and intra- and inter-assay relative errors (RE) were 2.0-8.4 and 1.9-9.1%, respectively. The lower limit of quantification (LLOQ) was 0.05 microg/ml. At this concentration mean intra- and inter-assay precisions were 7.8 and 7.5%, respectively, and mean intra- and inter-assay relative errors were 2.2 and 9.1%, respectively. Penciclovir was found to be stable in plasma samples under short-, long-term storage and processing conditions. The developed assay was successfully applied to a bioequivalence study of penciclovir administered as a single oral dose (500 mg as famciclovir) to healthy volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号