1.
The determination of 18 aromatic and arylaliphatic carboxylic acids in honey from different floral origin using solid-phase extraction (SPE) and reversed-phase high performance liquid chromatography (RP-HPLC) is reported. The behaviour of the solutes on SPE cartridges was predicted from preliminary calculations involving the pK(a) constants of the carboxylic groups, the n-octanol:water partition coefficients and the distribution coefficients at different pH values of the conditioning and washing solvents. The proposed SPE isolation and pre-concentration of the acids was achieved on reversed-phase Bond Elut C18 cartridges using an acetonitrile:tetrahydrofuran (1:1, v/v) elution system. RP-HPLC separations were performed on a Spherisorb ODS-2 column using linear gradient elution with a mobile phase composed of 20 mm phosphate buffer (pH 2.92) and methanol, and with UV detection. The reported SPE and RP-HPLC methods were applied to the analysis of 49 authentic honey samples from various floral sources and the results indicate that they may serve with respect to the quantitative control of a number of phenolic acids in plant-derived foods and medicinal plants.  相似文献   

2.
A highly sensitive quantitative method based on LC-MS/MS was developed to directly measure 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) and 2'-deoxyguanosine (dG) in crude DNA hydrolysates. With the use of isotopic internal standards and online solid-phase extraction (SPE), this method has overcome the artifactual response often observed during electrospray ionization by optimizing the washing conditions of online SPE to remove excess dG and allows 8-oxodG and dG to be accurately and simultaneously monitored by mass spectrometry. The detection limit of this method was estimated as 1.8 fmol for 8-oxodG. With this method, we further investigated the artifactual oxidation that occurred during concentration and purification of the DNA hydrolysates, commonly used before sample analysis. Our results demonstrated that drying under vacuum or purification with C18 cartridges led to a significant increase in the measured 8-oxodG by 6.8-30 8-oxodG/10(6) dG. The artifactual formation of 8-oxodG can be reduced only by adding desferrioxamine (DFO) and not 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO). However, DFO still failed to offer complete protection against oxidation during DNA hydrolysate concentration and purification. Therefore, to effectively prevent the artifacts formed during workup, the simplest approach is to use a direct measurement method involving an online enrichment/purification technique as proposed in this study.  相似文献   

3.
The newly established hyphenated instrumentation of LC/DAD/SPE/NMR and LC/UV/(ESI)MS techniques have been applied for separation and structure verification of the major known constituents present in Greek Hypericum perforatum extracts. The chromatographic separation was performed on a C18 column. Acetonitrile-water was used as a mobile phase. For the on-line NMR detection, the analytes eluted from column were trapped one by one onto separate SPE cartridges, and hereafter transported into the NMR flow-cell. LC/DAD/SPE/NMR and LC/UV/MS allowed the characterization of constituents of Greek H. perforatum, mainly naphtodianthrones (hypericin, pseudohypericin, protohypericin, protopseudohypericin), phloroglucinols (hyperforin, adhyperforin), flavonoids (quercetin, quercitrin, isoquercitrin, hyperoside, astilbin, miquelianin, I3,II8-biapigenin) and phenolic acids (chlorogenic acid, 3-O-coumaroylquinic acid). Two phloroglucinols (hyperfirin and adhyperfirin) were detected for the first time, which have been previously reported to be precursors in the biosynthesis of hyperforin and adhyperforin.  相似文献   

4.
Results of the simultaneous determination of the structurally different antibiotics cefazoline, cefotiame, cefuroxime, chloramphenicol, ciprofloxacin, ofloxacin, sulfamethoxazole and trimethoprim from environmental and biological monitoring using high-performance liquid chromatography with UV, single mass and tandem mass spectrometry were compared. For sample enrichment and clean-up a SPE method using bakerbond C18 cartridges was developed. Mean recovery rates were above 70%. Because of the complex urine matrix, only the wipe samples could be analyzed by UV-detection. However, UV-detection and single MS-detection are useful for control measurements after spillage, e.g. (LOD=1-2 ng/cm(2)). Samples from biological monitoring of occupational uptake should be analyzed by LC-MS/MS. The limits of detection (LOD) in urine ranged from 0.4 to 70 microg/L for LC-MS and 0.01 to 0.9 microg/L for LC-MS/MS detection. The limits of detection in wipe samples ranged from 0.003 to 0.13 ng/cm(2).  相似文献   

5.
Solid phase extraction (SPE) was coupled at line to capillary electrophoresis (CE) for the determination of three basic and neutral diabetic drugs (metformin, phenformin and glyburide) in human plasma. The SPE procedure employed a C(18) cartridge to remove most of the water and proteins from the plasma sample. Analyte detectability was increased due to trace enrichment during the SPE process. Elution of metformin, phenformin and glyburide was achieved with methanol+3% acetic acid. CE analysis was performed using a non-aqueous buffer, acetonitrile+5mM ammonium acetate+5% acetic acid, which afforded rapid separation of metformin from phenformin within 3 min. Glyburide, with a migration time longer than 6 min, did not cause any interference. The present SPE-CE method, with an electrokinetic injection time of 6s and UV detection at 240 nm, was useful for monitoring down to 1 microg/mL of metformin and phenformin in human plasma. When the electrokinetic injection time was increased to 36s, the detection limits were improved to 12 ng/mL for metformin and 6 ng/mL for phenformin.  相似文献   

6.
Sample pretreatment using solid-phase extraction (SPE) on cartridges filled with small-particle Styrosorb porous polystyrene-based sorbent has been used in the analysis of propranolol enantiomers in human serum by high-performance liquid chromatography (HPLC) with fluorescent detection. SPE on Sep-Pak C18 cartridges was used as a reference pretreatment method. The propranolol content of the samples was determined by achiral normal-phase HPLC and the enantiomeric ratio of propranolol (S/R) was then determined by chiral HPLC on a column with silica-bonded cellulose-tris(3,5-dimethylphenyl carbamate). Recoveries of propranolol from serum using SPE on Styrosorb and C18 phases were 97±5% and 96±5%, respectively. Detection and quantification limits for propranolol enantiomers were 4 and 7 ng/ml, respectively.  相似文献   

7.
Nanogram amounts of chlorimipramine, chlorpromazine and their Nor1- and Nor2-metabolites were detected in plasma by GLC with nitrogen-sensitive detection. Two extraction procedures were compared. The use of Sep Pak C18 cartridges produced a higher degree of accuracy and precision with significant time and materials saving, as compared to the use of organic solvents in a three steps extraction procedure.  相似文献   

8.
A rapid method to identify and quantify unconjugated progestogens in eggs is presented. Samples were prepared based on matrix solid-phase dispersion (MSPD) using C18 as dispersant, followed by a clean-up step with graphitized carbon black (GCB) solid-phase extraction (SPE) cartridges. The analytes were separated by very high pressure LC on a BEH C18 column for a period of 5 min. Electrospray ionization tandem mass spectrometry (ESI-MS/MS) was operated in the positive time-scheduled multi-reaction monitoring mode. Recovery studies were performed at two fortification levels. Average recoveries of the target compounds varied from 83.8% to 111.2% and relative standard deviations ranged from 10.5% to 23.7%. The limits of detection (LODs) and limits of quantitation (LOQs) were in the range of 0.2-2.0 microg kg(-1) and 0.6-5.0 microg kg(-1), respectively. Investigation of real samples indicated that the range of progesterone in eggs was 9.9-40.0 microg kg(-1).  相似文献   

9.
A novel analytical method employing MCX (mixed-mode cationic exchange) based solid phase extraction (SPE) coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed to detect 31 endocrine-disrupting compounds (EDCs) in surface water samples simultaneously. The target EDCs belong to five classes, including seven estrogens, eight androgens, six progesterones, five adrenocortical hormones and five industrial compounds. In order to simultaneously concentrate the target EDCs and eliminate matrix interferences in the water samples, MCX SPE cartridges were employed for SPE, and then followed by a simple and highly efficient three-step sequential elution procedure. Two electrospray ionization (ESI) detection modes, positive (ESI+) and (ESI-), were optimized for HPLC-MS/MS analysis to obtain the highest sensitivity for all the EDCs. The limits of detection (LODs) were 0.02-1.9 ng L(-1), which are lower than or comparable to these reported in references. Wide linear ranges (LOD-100 ng L(-1) for ESI+ mode, and LOD-200 ng L(-1) for ESI- mode) were obtained with determination coefficients (R(2)) higher than 0.99 for all the compounds. With five internal standards, good recoveries (84.4-103.0%) of all the target compounds were obtained in selected surface water samples. The developed method was successfully applied to investigate the EDCs occurrence in the surface water of Shanghai by analyzing surface water samples from 11 sites. The results showed that nearly all the target compounds (30 in 31) were present in the surface water samples of Shanghai, of which three industrial compounds (4-t-OP, BPA, and BPF) showed the highest concentrations (median concentrations were 11.88-23.50 ng L(-1)), suggesting that industrial compounds were the dominating EDCs in the surface water of Shanghai, and much more attention should be paid on these compounds. Our present research demonstrated that SPE with MCX cartridges combined with HPLC-MS/MS was convenient, efficient and reliable for multiclass analysis of EDCs in surface water.  相似文献   

10.
In clinical practice, the measurement of urinary free cortisol (UFC) provides the most sensitive and specific diagnostic information for excess adrenal production of cortisol. The existing methodologies (RIA and HPLC) are time consuming, costly, involve tedious extractions, derivatizations and problems with non-specific interactions with cortisol metabolites in urine. In the present study, we describe the development of an SPE–CE method for the rapid analysis of UFC. UFC was concentrated using SPE C18 cartridges (3M Empore) under a vacuum and eluted with acetonitrile–SDS. The use of 10% acetone to wash cartridges before final elution with acetonitrile–SDS showed significant improvements in the free cortisol recovery. The complete extraction was accomplished in 10–15 min with a recovery of 89–94%. CE analysis was done on a Beckman P/ACE 5010 with detection at 254 nm using a neutral capillary. Detection limits of free cortisol in urine was improved to 10 μg/l with SPE compared to 500 μg/l without SPE. No interferences either from BSA or other urinary cortisol metabolites affected the free cortisol determinations. The results showed the feasibility of a rapid UFC detection with improved sample handling capacity.  相似文献   

11.
A novel solid-phase extraction (SPE) method and HPLC method were developed for the determination of methadone and its metabolite from spiked human urine. For sample cleanup, a spiked urine sample was pretreated with phosphoric acid followed by a well-thought-out SPE method using a 10-mg Oasis HLB 96-well extraction plate. In this SPE method, the concentration of methanol as well as the pH are optimized to preferentially isolate the analytes of interest from the sample matrix. Low elution volumes (200 μl) are achieved; this eliminates evaporation and reconstitution of the sample solution. Recoveries from human urine matrix were greater than 91% with RSD values less than 4.5%. For the HPLC analysis, the separation was obtained using a SymmetryShield RP18 column with a mobile phase of 0.1% TFA–methanol (60:40, v/v). Good peak shapes were obtained without the need of addition of any competing reagent to the mobile phase. Additionally, significant signal-to-noise enrichment was achieved by diluting the final SPE eluates four-fold with water.  相似文献   

12.
A pit-stop semi-nested PCR assay for the detection of toxigenic Vibrio cholerae in environmental water samples was developed and its performance evaluated. The PCR technique amplifies sequences within the cholera toxin operon specific for toxigenic V. cholerae. The PCR procedure coupled with an enrichment culture detected as few as four V. cholerae organisms in pure culture. Treated sewage, surface, ground and drinking water samples were seeded with V. cholerae and following enrichment, a detection limit of as few as 1 V. cholerae cfu ml(-1) was obtained with amplification reactions from crude bacterial lysates. The proposed method, which includes a combination of enrichment, rapid sample preparation and a pit-stop semi-nested PCR, could be applicable in the rapid detection of toxigenic V. cholerae in environmental water samples.  相似文献   

13.
Aims:  We performed a preliminary assessment of the eukaryotic 18S rDNA diversity present in finished drinking water samples from three different surface water treatment plants supplying water to the city of Paris (France).
Methods and Results:  A molecular analysis was performed on a sample from each site based on sequencing of PCR amplified and cloned 18S ribosomal RNA genes. Overall, the 18S rDNA sequences combined from all samples could be affiliated to the Amoebozoa (20·8% of the phylotypes), Ciliophora (25%), Metazoa (33·3%), Fungi (8·3%), Cercozoa (4·2%) and unclassified eukaryotes (8·3%) groups.
Conclusions:  The 18S rDNA sequences affiliated to the Amoebozoa, Ciliophora and Metazoa lineages were found to be the most abundant phylotypes observed in the drinking water samples. Phylotypes found to be present in two, or all three, samples (41·7% of the total) may represent groups with members adapted to drinking water treatment plant (DWTP) ecosystem conditions.
Significance and Impact of the Study:  This study shows that finished drinking water can contain 18S rDNA sequences representing a variety of eukaryotic taxa. Further research is needed to better characterize the eukaryotic biodiversity of DWTPs and the effects of the finished drinking water diversity on the downstream water distribution network.  相似文献   

14.
A rapid and sensitive assay was developed for detection of small numbers of Campylobacter jejuni and Campylobacter coli cells in environmental water, sewage, and food samples. Water and sewage samples were filtered, and the filters were enriched overnight in a nonselective medium. The enrichment cultures were prepared for PCR by a rapid and simple procedure consisting of centrifugation, proteinase K treatment, and boiling. A seminested PCR based on specific amplification of the intergenic sequence between the two Campylobacter flagellin genes, flaA and flaB, was performed, and the PCR products were visualized by agarose gel electrophoresis. The assay allowed us to detect 3 to 15 CFU of C. jejuni per 100 ml in water samples containing a background flora consisting of up to 8, 700 heterotrophic organisms per ml and 10,000 CFU of coliform bacteria per 100 ml. Dilution of the enriched cultures 1:10 with sterile broth prior to the PCR was sometimes necessary to obtain positive results. The assay was also conducted with food samples analyzed with or without overnight enrichment. As few as 相似文献   

15.
Two simple, sensitive and reproducible methods for determination of total mycophenolic acid (MPA) and its glucuronide metabolite (MPAG) as well as unbound MPA (fMPA) was developed by the use of HPLC-UV and LC-MS/MS methods, respectively. For the total MPA/MPAG method, the analytes were extracted using Isolute C(2) solid-phase extraction (SPE) cartridges and analyzed at 254 nm over a Zorbax Rx C(8) column (150 mm x 4.6 mm, 5 microm). The mobile phase was a gradient mixture of methanol and water (containing 0.1% (v/v) phosphoric acid). The total run time was 18 min and the extraction recovery was 77% for MPA and 84% for MPAG. The method was precise and accurate with a lower limit of quantification (LLOQ) of 0.5 mg/l for MPA and 5.0 mg/l for MPAG. For the fMPA method, plasma was subjected to ultrafiltration followed by SPE using C(18) cartridges. Analytical column was the same as the HPLC-UV method and the mobile phase was a gradient composition of methanol:0.05% formic acid with a flow rate of 0.6 ml/min for the first 3 min and 0.7 ml for the last 4 min. The chromatographic method separated MPA from its metabolites MPAG and Acyl-MPAG. Mass transitions in negative ionization mode for MPA and the internal standard, indomethacin were m/z: 319-->190.9 and m/z: 356-->312.2, respectively. The assay was linear in the concentration range of 1-1000 microg/l for fMPA with a LLOQ of 1 microg/l and an accuracy of >95%. The two methods reported have an adequate degree of robustness and dynamic concentration range for the measurement of MPA, MPAG and fMPA for therapeutic drug monitoring purposes or pharmacokinetics investigations.  相似文献   

16.
Quantitative analysis of therapeutic compounds and their metabolites in biological matrix (such as plasma, serum or urine) nowadays requires sensitive and selective methods to allow the determination of concentrations in the ng/ml range. A new on-line LC–MS–MS method using atmospheric pressure chemical ionisation (APCI) as interface for the simultaneous determination of nifedipine (NIF) and its metabolite in human plasma, dehydronifedipine (DNIF) has been developed. The compounds were extracted from plasma using solid-phase extraction (SPE) on disposable extraction cartridges (DECs). The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with phenyl modified silica was first conditioned with methanol and water. The washing step was performed with water. Finally, the analytes were successively eluted with methanol and water. The liquid chromatographic (LC) separation of NIF and DNIF was achieved on a RP-18 stationary phase (4 μm). The mobile phase consisted of methanol–50 mM ammonium acetate solution (50:50, v/v). The LC was then coupled to tandem mass spectrometry with an APCI interface in the positive ion mode.

The method developed was validated. The absolute recoveries evaluated over the whole concentration range were 95±2% and 95±4% for NIF and DNIF, respectively. The method was found to be linear in the 0.5–100 ng/ml concentration range for the two analytes (r2=0.999 for both NIF and DNIF). The mean R.S.D. values for repeatability and intermediate precision were 2.9 and 3.0% for NIF and 2.2–4.7% for the metabolite.The method developed was successfully used to investigate the plasma concentration of NIF and DNIF in the pharmacokinetic studies.  相似文献   


17.
Rapid and simple achiral and chiral HPLC assays have been developed for the determination of verapamil and its metabolites in serum samples. Two achiral reversed-phase columns, Hisep C18 (150×4.6 mm) and NovaPak C18 (150×3.9 mm) were used for the simultaneous separation of all analyzed compounds. An α1-AGP column (100×4.0 mm) was recommended for successful chiral separations of verapamil and its seven metabolites. All analyses were realised with fluorescence detection at λex=276 nm and λem=310 nm. Limits of quantitation were in the range 1.0 to 5 ng/ml for all compounds. Both off-line SPE (SepPak C18 cartridges) and the on-line SPE with a semipermeable surface SDS C8 pre-column, (10×4.6 mm) were used for the clean-up and sample preconcentration. Extraction recoveries for all analyzed compounds were 87.7±5.8 to 92.7±4.0% for off-line SPE and 94.3±4.2 to 98.2±5.1% for on-line SPE. The complete assay could be applied for achiral and chiral monitoring verapamil and all its metabolites in serum samples.  相似文献   

18.
AIMS: To use a published polymerase chain reaction (PCR) method for the detection and identification of thermotolerant Campylobacter species (Camp. jejuni, Camp. coli and Camp. lari) in tandem with a Most Probable Number (MPN) technique to enumerate these species in water samples. METHODS AND RESULTS: An initial study of 42 river water samples compared the use of conventional culture and PCR methods for the detection of Campylobacter in MPN enrichment tubes. It was found that all samples positive by culture were also positive by PCR. Thirty-seven percent more MPN tubes were positive by PCR compared with culture. The MPN/PCR technique was subsequently applied to 96 additional samples collected from rivers, drinking, roof and shallow ground water. Campylobacter was especially prevalent in river water (60% positive) and shallow ground water (75% positive) samples. Drinking water (29.2% positive) and roof water (37.5% positive) also contained Campylobacter, but the numbers detected were very low (maximum 0.3 and 0.56 MPN 100 ml-1, respectively). CONCLUSION: River waters contained Campylobacter at higher levels than any other water type and in a high percentage of the samples. Although Campylobacter was present in treated drinking water, the levels detected were low. SIGNIFICANCE AND IMPACT OF THE STUDY: These results suggest that water may act as a significant transmission route for human campylobacteriosis.  相似文献   

19.
Waterborne outbreaks associated with contamination of drinking water by Campylobacter jejuni are rather common in the Nordic countries Sweden, Norway, and Finland, where in sparsely populated districts groundwater is commonly used without disinfection. Campylobacters, Escherichia coli, or other coliforms have rarely been detected in potential sources. We studied three waterborne outbreaks in Finland caused by C. jejuni and used sample volumes of 4,000 to 20,000 ml for analysis of campylobacters and sample volumes of 1 to 5,000 ml for analysis of coliforms and E. coli, depending on the sampling site. Multiple samples obtained from possible sources (water distribution systems and environmental water sources) and the use of large sample volumes (several liters) increased the chance of detecting the pathogen C. jejuni in water. Filtration of a large volume (1,000 to 2,000 ml) also increased the rate of detection of coliforms and E. coli. To confirm the association between drinking water contamination and illness, a combination of Penner serotyping and pulsed-field gel electrophoresis (digestion with SmaI and KpnI) was found to be useful. This combination reliably verified similarity or dissimilarity of C. jejuni isolates from patient samples, from drinking water, and from other environmental sources, thus confirming the likely reservoir of an outbreak.  相似文献   

20.
A micronucleus test in gill cells of the freshwater mussel Anodonta cygnea has been proposed for the detection of drinking water genotoxicity. Animals were exposed for 28 days to a drinking water sample and collected every week. Highly significant increases in spontaneous MN frequency were observed at each sampling, especially after 13 days of exposure. As positive control 2 doses of mytomicin C (MMC) were used (10(-8) and 10(-7) M). A second experiment was performed at a municipal waterworks in order to assess the role of water treatment processes in the production of mutagenic compounds. The most prevalent genotoxic effects were detected after chlorination (mean: 10.47% +/- 3.05, p less than 0.001).  相似文献   