1.
A study was performed to assess the feasibility of anaerobic treatment of slaughterhouse wastewaters in a UASB (Upflow Anaerobic Sludge Blanket) reactor and in an AF (Anaerobic Filter). Among the different streams generated, the slaughter line showed the highest organic content with an average COD of 8000 mg/l, of which 70% was proteins. The suspended solids content represented between 15 and 30% of the COD. Both reactors had a working volume of 21. They were operated at 37°C. The UASB reactor was run at OLR (Organic Loading Rates) of 1–6.5 kg COD/m3/day. The COD removal was 90% for OLR up to 5 kg COD/m3/day and 60% for an OLR of 6.5 kg COD/m3/day. For similar organic loading rates, the AF showed lower removal efficiencies and lower percentages of methanization. At higher OLR sludge, flotation occurred and consequently the active biomass was washed out from the filter. The results indicated that anaerobic treatment systems are applicable to slaughterhouse wastewaters and that the UASB reactor shows a better performance, giving higher COD removal efficiencies than the AF.  相似文献   

2.
Anaerobic co-digestion of fruit and vegetable waste (FVW) and abattoir wastewater (AW) was investigated using anaerobic sequencing batch reactors (ASBRs). The effects of hydraulic retention time (HRT) and temperature variations on digesters performances were examined. At both 20 and 10 days biogas production for co-digestion was greater thanks to the improved balance of nutrients. The high specific gas productions for the different digestion processes were 0.56, 0.61 and 0.85 l g−1 total volatile solids (TVS) removal for digesters treating AW, FVW and AW + FVW, respectively. At an HRT of 20 days, biogas production rates from thermophilic digesters were higher on average than from mesophilic AW, FVW and AW + FVW digestion by 28.5, 44.5 and 25%, respectively. However, at 10 days of HRT results showed a decrease of biogas production rate for AW and AW + FVW digestion processes due to the high amount of free ammonia at high organic loading rate (OLR).  相似文献   

3.
Kim HW  Nam JY  Shin HS 《Bioresource technology》2011,102(15):7272-7279
Assessing contemporary anaerobic biotechnologies requires proofs on reliable performance in terms of renewable bioenergy recovery such as methane (CH4) production rate, CH4 yield while removing volatile solid (VS) effectively. This study, therefore, aims to evaluate temperature-phased anaerobic sequencing batch reactor (TPASBR) system that is a promising approach for the sustainable treatment of organic fraction of municipal solid wastes (OFMSW). TPASBR system is compared with a conventional system, mesophilic two-stage anaerobic sequencing batch reactor system, which differs in operating temperature of 1st-stage. Results demonstrate that TPASBR system can obtain 44% VS removal from co-substrate of sewage sludge and food waste while producing 1.2 m3CH4/m3system/d (0.2 m3CH4/kgVSadded) at organic loading rate of 6.1 gVS/L/d through the synergy of sequencing-batch operation, co-digestion, and temperature-phasing. Consequently, the rapid and balanced anaerobic metabolism at thermophilic stage makes TPASBR system to afford high organic loading rate showing superior performance on OFMSW stabilization.  相似文献   

4.
Wang W  Ma W  Han H  Li H  Yuan M 《Bioresource technology》2011,102(3):2441-2447
Lurgi coal gasification wastewater (LCGW) is a refractory wastewater, whose anaerobic treatment has been a severe problem due to its toxicity and poor biodegradability. Using a mesophilic (35 ± 2 °C) reactor as a control, thermophilic anaerobic digestion (55 ± 2 °C) of LCGW was investigated in a UASB reactor. After 120 days of operation, the removal of COD and total phenols by the thermophilic reactor could reach 50-55% and 50-60% respectively, at an organic loading rate of 2.5 kg COD/(m3 d) and HRT of 24 h; the corresponding efficiencies were both only 20-30% in the mesophilic reactor. After thermophilic digestion, the wastewater concentrations of the aerobic effluent COD could reach below 200 mg/L compared with around 294 mg/L if mesophilic digestion was done and around 375 mg/L if sole aerobic pretreatment was done. The results suggested that thermophilic anaerobic digestion improved significantly both anaerobic and aerobic biodegradation of LCGW.  相似文献   

5.
Anaerobic co-digestion of press mud with water or sewage at ratios of 1:7.5, 1:10 and 1:12.5 were performed in continuously fed UASB reactors for hydrogen production. At a constant hydraulic retention time of 30 h, the specific hydrogen production rate was 187 mL/g volatile solids (VS) reduced during maximum biohydrogen production of 7960 mL/day at a 1:10 ratio of press mud to sewage. Chemical oxygen demand (COD) and VS reductions of 61% and 59% were noted on peak biohydrogen yield. A pH range of 5-6 was suitable at ambient temperature for entire process; a lower pH was inhibitory. Co-digestion of acidic press mud with sewage controlled pH for fermentation. Hence press mud can be exploited for biohydrogen production.  相似文献   

6.
Hwu CS  Lu CJ 《Biotechnology letters》2008,30(9):1589-1593
Influences of hydraulic retention time (HRT) on dechlorination of tetrachloroethene (PCE) were investigated in an upflow anaerobic sludge blanket (UASB) reactor inoculated with anaerobic granular sludge non-pre-exposed to chlorinated compounds. PCE was introduced into the reactor at a loading rate of 3 mg/l d. PCE removal increased from 51 +/- 5% to 87 +/- 3% when HRT increased from 1 to 4 d, corresponding to an increase in the PCE biotransformation rate from 10.5 +/- 2.3 to 21.3 +/- 3.7 mumol/d. A higher ethene production rate, 0.9 +/- 0.2 mumol/d, was attained without accumulation of dichloroethenes at the HRT of 4 d. Dehalococcoides-like species were detected in sludge granules by fluorescence in situ hybridization, with signal strength in proportion to the extent of PCE dechlorination.  相似文献   

7.
The anaerobic digestion of cheese whey was studied in a UASB reactor. The profiles of the reactor, i.e., the distributions of the substrate concentration and pH under different operating conditions were developed. From the concentrations of substrates measured at various levels above the bottom of the reactor, two reaction stages, namely acidogenesis and methanogenesis, were distinguished. The instability caused by high influent concentration was interpreted as the accumulation of VFAs in the acidogenic stage beyond the assimilative capacity of the methanogenic stage. A range of stable operating conditions was predicted from the results of the profile measurements. The optimal influent concentration was found to be between 25 and 30 g COD/L at an HRT of 5 days for system stability. Other options fro stability control were discussed. (c) 1993 John Wiley & Sons, Inc.  相似文献   

8.
Khanh D  Quan L  Zhang W  Hira D  Furukawa K 《Bioresource technology》2011,102(24):11147-11154
The feasibility of treating low-strength wastewater with an up-flow anaerobic sludge blanket (UASB) reactor, using a poly(vinyl alcohol)-gel carrier, at various temperatures and hydraulic retention times (HRTs) was examined. The temperature was decreased from 35°C to 25°C and then to 15°C. The HRT was reduced from 2.0 h to 0.22 h. The COD removal rate reached 28 kg-COD m(-3)d(-1) at 35°C, 16 kg-COD m(-3)d(-1) at 25°C, and 6 kg-COD m(-3)d(-1) at 15°C. The COD removal rate was reduced by half for each temperature reduction of 10°C.  相似文献   

9.
The treatment of high strength sewage was investigated in a one-stage upflow anaerobic sludge blanket (UASB) reactor and a UASB-digester system. The one-stage UASB reactor was operated in Palestine at a hydraulic retention time (HRT) of 10h and at ambient air temperature for a period of more than a year in order to asses the system response to the Mediterranean climatic seasonal temperature fluctuation. Afterwards, the one-stage UASB reactor was modified to a UASB-digester system by incorporating a digester operated at 35 degrees C. The achieved removal efficiencies in the one-stage UASB reactor for total, suspended, colloidal, dissolved and VFA COD were 54, 71, 34, 23%, and -7%, respectively during the first warm six months of the year, and achieved only 32% removal efficiency for COD total over the following cold six months of the year. The modification of the one-stage UASB reactor to a UASB-digester system had remarkably improved the UASB reactor performance as the UASB-digester achieved removal efficiencies for total, suspended, colloidal, dissolved and VFA COD of 72, 74, 74, 62 and 70%. Therefore, the anaerobic treatment of high strength sewage during the hot period in Palestine in a UASB-digester system is very promising.  相似文献   

10.
An anaerobic digestion technique was applied to textile dye wastewater aiming at the colour and COD removal. Pet bottles of 5 L capacity were used as reactor which contains methanogenic sludge of half a liter capacity which was used for the treatment of combined synthetic textile dye and starch wastewater at different mixing ratios of 20:80, 30:70, 40:60, 50:50 and 60:40 with initial COD concentrations as 3520, 3440, 3360, 3264 and 3144 mg L−1, respectively. The reactor was maintained at room temperature (30 ± 3 °C) with initial pH of 7. The maximum COD and colour removal were 81.0% and 87.3% at an optimum mixing ratio of 30:70 of textile dye and starch wastewaters. Both Monod’s and Haldane’s models were adopted in this study. The kinetic constants of cell growth under Haldane’s model were satisfactory when compared to Monod’s model. The kinetic constants obtained by Haldane’s model were found to be in the range of μmax = 0.037-0.146 h−1, Ks = 651.04-1372.88 mg L−1 and Ki = 5681.81-18727.59 mg L−1.  相似文献   

11.
Li Y  Yan XL  Fan JP  Zhu JH  Zhou WB 《Bioresource technology》2011,102(11):6458-6463
The objective of this work was to examine the feasibility of biogas production from the anaerobic co-digestion of herbal-extraction residues with swine manure. Batch and semi-continuous experiments were carried out under mesophilic anaerobic conditions. Batch experiments revealed that the highest specific biogas yield was 294 mL CH4 g−1 volatile solids added, obtained at 50% of herbal-extraction residues and 3.50 g volatile solids g−1 mixed liquor suspended solids. Specific methane yield from swine manure alone was 207 mL CH4 g−1 volatile solid added d−1 at 3.50 g volatile solids g−1 mixed liquor suspended solids. Furthermore, specific methane yields were 162, 180 and 220 mL CH4 g−1 volatile solids added d−1 for the reactors co-digesting mixtures with 10%, 25% and 50% herbal-extraction residues, respectively. These results suggested that biogas production could be enhanced efficiently by the anaerobic co-digestion of herbal-extraction residues with swine manure.  相似文献   

12.
Li J  Wang J  Luan Z  Deng Y  Chen L 《Bioresource technology》2011,102(10):5709-5716
A two-stage UASB reactor was employed to pretreat acrylic fiber manufacturing wastewater. Mesophilic operation (35 ± 0.5 °C) was performed with hydraulic retention time (HRT) varied between 28 and 40 h. Mixed liquor suspended solids (MLSS) in the reactor was maintained about 8000 mg/L. The results showed COD and sulfate removal could be kept at 51% and 75%, respectively, when the HRT was no less than 38 h. Sulfate reduction mainly occurred in the acidification-stage reactor while methane production mainly occurred in the methane-stage reactor. The size of granule formed in the acidification-stage reactor ranged between 1 and 5 mm while the largest size of granule in the methane-stage reactor ranged from 0.5 to 2 mm. Compared to microbial populations in the acidification-stage reactor, the microbial diversity in methane-stage reactor was more abundant. In the acidification-stage reactor, the Syntrophobacter sulfatireducens devoted to both sulfate reduction and acetate production.  相似文献   

13.
In this study, a promising system consisting of up-flow anaerobic sludge blanket (UASB) reactor followed by down-flow hanging sponge (DHS) reactor was investigated for onion dehydration wastewater treatment. Laboratory experiments were conducted at two different phases, i.e., phase (1) at overall hydraulic retention time (HRT) of 11 h (UASB reactor: 6 h and DHS reactor: 5 h) and phase (2) at overall HRT of 9.4 h (UASB reactor: 5.2 h and DHS reactor: 4.2 h). Long-term operation results of the proposed system showed that its overall TCOD, TBOD, TSS, TKN and NH4N removal efficiencies were 92 ± 5, 95 ± 2, 95 ± 2, 72 ± 6 and 99 ± 1.3%, respectively (phase 1). Corresponding values for the 2nd phase were 85.4 ± 5, 86 ± 3, 87 ± 6, 65 ± 8 and 95 ± 2.8%. Based on the available results, the proposed system could be more viable option for treatment of wastewater generated from onion dehydration industry in regions with tropical or sub-tropical climates and with stringent discharge standards.  相似文献   

14.
In this paper, trace elements (TE) adding was investigated in one bench-scale UASB reactor treating solo simple molecule wastewater with the aim of evaluating its effect on enhancing biofilm formation. After adding sufficient TE (3 mL/L) in the influent, during 3 days, COD removal efficiency increased from 74% to 90% comparing to no adding TE. Over 55 days of operation, the organic loading rate (OLR) reached 11 g/L/day with COD removal efficiencies greater than 90%. While in the steady running period no effect even improvement on treatment performance was observed without any TE adding. The results illuminated that TE accounted for quick start-up of the UASB biofilm system rather than ever known biocatalyst.  相似文献   

15.
The performance of an anaerobic hybrid reactor (AHR) for treating penicillin-G wastewater was investigated at the ambient temperatures of 30-35 °C for 245 days in three phases. The experimental data were analysed by adopting an adaptive network-based fuzzy inference system (ANFIS) model, which combines the merits of both fuzzy systems and neural network technology. The statistical quality of the ANFIS model was significant due to its high correlation coefficient R2 between experimental and simulated COD values. The R2 was found to be 0.9718, 0.9268 and 0.9796 for the I, II and III phases, respectively. Furthermore, one to one correlation among the simulated and observed values was also observed. The results showed the proposed ANFIS model was well performed in predicting the performance of AHR.  相似文献   

16.
The anaerobic digestion of pure glycerol, which produces a baseline acetic acid to propionic acid ratio of 0.2, was studied in laboratory scale reactors (3 l working volume) at mesophilic temperature (37 °C) with 3000 mg chemical oxygen demand (COD) l−1d−1. During the experiment tVFA and C2-C6 VFA analysis and daily biogas yield measurement were carried out. Following 10 days of a 15% d−1 increase in the organic loading rate (OLR) of 3.0-10.5 g COD l−1d−1, the concentration of propionic acid increased to 6200-8000 mg l−1. Then the inoculum was divided into three parts feeding with 100% glycerol, 50% glycerol + 50% acetic acid, and 50% glycerol + 50% thick stillage, (presented in % of 2.60 g COD l−1d−1 OLR), respectively. The application of co-substrates reduced the recovery period by 5 days compared to feeding with pure glycerol. When the reactors were loaded with glycerol again (10% OLR raise per day) the previously applied co-substrates had a positive effect on the VFA composition and the biogas yield as well.  相似文献   

17.
The start-up tests of treating soybean protein wastewater by the integrated two-phase anaerobic reactor were studied. The results showed that the soybean protein wastewater could be successfully processed around 30 days when running under the situation of dosing seed sludge with the influent of approximately 2000 mg/L and an HRT of 40 h. When the start-up was finished, the removal rate of COD by the reactor was about 80%. In the zone I, biogas mainly revealed carbon dioxide (CO2) and hydrogen (H2). Methane was the main component in the zone 2 which ranged from 53% to 59% with an average of 55%. The methane content in biogas increased from the zone I to II. It indicated that the methane-producing capacity of the anaerobic sludge increased. It was found that the uniquely designed two-phase integrated anaerobic reactor played a key role in treating soybean protein wastewater. The acidogenic fermentation bacteria dominated in the zone I, while methanogen became dominant in the zone II. It realized the relatively effective separation of hydrolysis acidification and methanogenesis process in the reactor, which was benefit to promote a more reasonable space distribution of the microbial communities in the reactor. There were some differences between the activities of the sludge in the two reaction zones of the integrated two-phase anaerobic reactor. The activity of protease was higher in the reaction zone I. And the coenzyme F420 in the reaction zone II was twice than that in the reaction zone I, which indicated that the activity of the methanogens was stronger in the reaction zone II.  相似文献   

18.
Zhang L  Lee YW  Jahng D 《Bioresource technology》2011,102(8):5048-5059
The objective of this study was to evaluate the feasibility of anaerobic co-digestion of food waste and piggery wastewater, and to identify the key factors governing the co-digestion performance. The analytical results indicated that the food waste contained higher energy potential and lower concentrations of trace elements than the piggery wastewater. Anaerobic co-digestion showed a significantly improved biogas productivity and process stability. The results of co-digestion of the food waste with the different fractions of the piggery wastewater suggested that trace element might be the reason for enhancing the co-digestion performance. By supplementing the trace elements, a long-term anaerobic digestion of the food waste only resulted in a high methane yield of 0.396 m3/kg VSadded and 75.6% of VS destruction with no significant volatile fatty acid accumulation. These results suggested that the typical Korean food waste was deficient with some trace elements required for anaerobic digestion.  相似文献   

19.
Nitrobenzene (NB) is an important industrial raw material in organic synthesis. However, successful biological treatment is challenging since NB wastewater is biologically toxic. During the experiment, the performance was examined during the acclimation process of NB in an anaerobic baffled reactor (ABR). The removal efficiencies of NB and chemical oxygen demand were 98% and 90%, respectively. Furthermore, by applying polymerase chain reaction-denaturing gradient gel electrophoresis (DGGE) technology of 16SrDNA, this paper analyzes the structural change of the archaea community in the ABR before and after NB acclimation and identifies the dominant community. The sequence structure analysis of archaea 16S rDNA in DGGE profiles shows that after NB biodegradation, the archaea-dominant community primarily consists of Methanothrix soehngenii from Methanosarcina, Methanosaeta concilii from Methanosaeta, Methanobacterium beijingense 8-2, uncultured Archaeon TA04, and uncultured Methanobacterium sp. isolated from environmental samples, which may be the important functional archaea in an ABR for NB biodegradation. The study of the population structure distribution and the dominant archaea community is helpful for elucidating the mechanisms of the anaerobic biodegradation mechanism of NB.  相似文献   

20.
Diesel fuel spills have a major impact on the quality of groundwater. In this work, the performance of an Anaerobic Fluidized Bed Reactor (AFBR) treating synthetic wastewater is experimentally evaluated. The wastewater comprises tap water containing 100, 200 and 300 mg/L of diesel fuel and nutrients. Granular, inert, activated carbon particles are employed to provide support for biomass inside the reactor where diesel fuel is the sole source of carbon for anaerobic microorganisms. For different rates of organic loading, the AFBR performance is evaluated in terms of the removal of diesel fuel as well as chemical oxygen demand (COD) from wastewater. For the aforementioned diesel fuel concentrations and a wastewater flow rate of 1,200 L/day, the COD removal ranges between 61.9 and 84.1%. The concentration of diesel fuel in the effluent is less than 50 mg/L, and meets the Level II groundwater standards of the MUST guidelines of Alberta.  相似文献   