首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An amperometric immunosensor in the competitive format was developed for the detection of methamphetamine in urine. The electrodes consisted of carbon paste and Ag/AgCl screen printed on heat sealing film, respectively, and of monoclonal anti-methamphetamine antibody as the biorecognition element. Optimum amounts of methamphetamine- N -bovine serum albumin conjugate, monoclonal antibody and alkaline phosphatase-goat anti-mouse immunoglobulin G were 20, 10 ng and 1:10,000 dilution in 10 μl each, respectively. Methamphetamine was detected by the conversion of p -aminophenyl phosphate to electroactive p -aminophenol in the range of 200 ng/ml (lower detection limit) to 1,500 ng/ml methamphetamine in a nearly linear dose response curve. Within amphetamine concentrations of 0-1,500 ng/ml cross-reaction with methamphetamine was not observed. Working with urine samples spiked with methamphetamine, the accuracy and precision of the assay were 91.5-104.4% and 15.8-24.4%, respectively. This is a proof of concept in the clinical perspective for an amperometric immunosensor whose electrodes are amenable to future mass production.  相似文献   

2.
Liu G  Chen H  Peng H  Song S  Gao J  Lu J  Ding M  Li L  Ren S  Zou Z  Fan C 《Biosensors & bioelectronics》2011,28(1):308-313
Carbon nanotubes have shown their unique advantages of mechanical, chemical and electronic properties in bioanalysis. We herein report a new method to efficiently and reproducibly prepare multi-walled carbon nanotubes (MWNTs)-protein sensing layers for electrochemical immunosensors. This method employs centrifugation to prepare a conjugate of MWNTs and goat anti mouse-immunoglobulin G (IgG) (secondary antibody). The conjugates were then deposited on screen-printed electrodes to form a nanostructured layer (MWNT-I layer). CLB monoclonal antibody was assembled through its binding to the secondary antibody. The MWNT-I layer-based electrodes were used for rapid and sensitive amperometric immunosensing detection of clenbuterol (CLB) in swine urine samples. Horseradish peroxidase-coupled CLB (CLB-HRP) competed with free CLB in the samples to bind the monoclonal antibody. It has shown significantly higher sensitivity and better reproducibility than the chemical conjugation method. This MWNT-based immunosensor is highly sensitive, leading to a limit of detection of 0.1 ng/mL within a rapid assay time of 16 min. Its sensitivity is at least 1 order of magnitude higher than that of a normal immunosensor (without MWNTs). The sensing device is portable with disposable screen-printed electrode, satisfactorily meeting the requirements for field detection of food security-related species.  相似文献   

3.
Development of an electrochemical immunosensor for alanine aminotransferase   总被引:1,自引:0,他引:1  
Alanine aminotransferase (ALT) has been regarded as one of the most sensitive indicators of hepatocellular damage. While ALT is widely used in the practice of medicine, few attempts have been made to develop biosensors applicable to the on-site diagnosis of liver diseases. In the hope of developing an immunosensor for measurement of ALT activity, we have generated monoclonal antibodies to human recombinant ALT and fabricated them for use in a sensor. The ALT immunosensor was composed of the followings: (1) anti-ALT antibody-immobilized outer membrane; (2) pyruvate oxidase-absorbed inner membrane; (3) a self assembled monolayer mediator-coated gold working electrode and an Ag/AgCl reference electrode. The chronoamperometric measurement of the immunosensor was performed with 40 microl of PBS containing substrates and ALT without a washing step in less than 5 min. The dynamic range of ALT immunosensor was presented as five orders of magnitude, ranging between 10 pg/ml and 1 microg/ml. The detection limit and the sensitivity were 10 pg/ml and 26.3 nA/(ng/ml), respectively. In the meantime, the enzyme sensor fabricated without anti-ALT antibody showed much poorer analytical values. The dynamic range, the detection limit, and the sensitivity were 10 ng/ml-100 microg/ml, 10 ng/ml and 11.4 nA/(ng/ml), respectively. The presented results indicated that the immunosensor system provided much better technical performance in all of the aspects evaluated than did the enzyme sensor without the immobilized-antibody.  相似文献   

4.
An amperometric immunosensor for polycyclic aromatic hydrocarbons (PAHs) was developed. The immunosensor was based on disposable screen-printed carbon electrodes. The coating antigen used was phenanthrene-9-carboxaldehyde coupled to bovine serum albumin (BSA) via adipic acid dihydrazide. Antibodies were monoclonal mouse anti-phenanthrene. The enzyme alkaline phosphatase (AP) was used in combination with the substrate p-aminophenyl phosphate (pAPP) for detection at +300 mV (vs. Ag/AgCl). Various assay types were compared. Good results were achieved with an indirect co-exposure competition assay with a LOD of 0.8 ng/ml (800 ppt) and an IC(50) of 7.1 ng/ml (7.1 ppb) for phenanthrene. An indirect competition assay could detect phenanthrene with a LOD of 2 ng/ml (IC(50): 15 ng/ml) and an indirect displacement assay with a LOD of 2 ng/ml (IC(50): 11 ng/ml) at a 5 microl surface coating of 8.8 microg/ml phenanthrene-BSA conjugate. A coating concentration of 2.2 microg/ml allowed detection with a LOD of 0.25 ng/ml (250 ppt) with the indirect competition assay. The influence of the coating concentration on the sensor performance was investigated. Cross-reactivities were tested for 16 important PAHs. Anthracene and chrysene showed strong cross-reactivity, whereas benzo[g,h,i]perylene and dibenzo[a,h]anthracene showed no cross-reactivity.  相似文献   

5.
A novel amperometric immunosensor for the detection of the p24 antigen (p24Ag) from HIV-1 was constructed using gold nanoparticles (GNP), multi-walled carbon nanotubes (MWCNTs), and an acetone-extracted propolis film (AEP). First, amino-functionalized MWCNTs (MWCNTNH?) were prepared and dispersed in an HAuCl? solution to synthesize GNPs in situ. Next, the GNP/CNT/AEP nanocomposite was prepared by mixing an AEP solution and the GNP/CNT powder. The nanocomposite was dripped onto a gold electrode (GE), and then p24 antibody (anti-p24 Ab) was immobilized on the resulting modified gold electrode to construct the immunosensor. The assembly process was characterized using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The factors that were likely to influence the performance of the proposed immunosensor were studied in detail. Under optimal conditions, the proposed immunosensor exhibited good electrochemical sensitivity to the presence of p24 in a concentration range of 0.01 to 60.00 ng/mL, with a relatively low detection limit of 0.0064 ng/mL (S/N = 3). Moreover, the proposed immunosensor showed a rapid (≤ 18 s) and highly sensitive amperometric response (0.018 and 1.940 μA/ng/mL) to p24 with acceptable stability and reproducibility.  相似文献   

6.
An amperometric immunosensor specific to the protein A of Staphylococcus aureus, was developed using the direct electrochemical detection of phenol produced by alkaline phosphatase from phenylphosphate. The immunosensor could detect protein A at 0.01 ng/ml and could reliably detect and quantify pure cultures of protein A-bearing Staph. aureus above 10(3) cfu/ml. A similar sensitivity of detection was obtained with samples of beef and milk.  相似文献   

7.
A disposable amperometric immunosensor was studied for the rapid detection of carp (Carassius auratus) Vitellogenin (Vtg). The sensor was fabricated based on screen-printed carbon arrays (SPCAs) containing eight carbon working and an integrated carbon counter electrodes. To construct the sensor, a conducting polymer (poly-terthiophene carboxylic acid) was electropolymerized on the surface of working electrodes and the polymer-coated SPCAs was characterized by SEM. Horseradish peroxidase (HRP) and a monoclonal antibody (anti-Vtg) specific to carp Vtg were covalently attached onto the polymer modified SPCAs. The immobilization of HRP and anti-Vtg onto the polymer-coated SPCAs was examined using cyclic voltammetry and quartz crystal microbalance studies. In order to detect the amount of Vtg, glucose oxidase (GOx)-labelled Vtg bound to the sensor surface under competition with the Vtg analyte was quantified amperometrically using glucose as a substrate. The performance of the eight sensors in arrays was evaluated by obtaining the calibration plots for Vtg. The sensor arrays exhibit a linear range of the Vtg concentration from 0.25 to 7.8 ng/ml and the detection limit was determined to be 0.09 ng/ml. Furthermore, the performance of the immunosensor for the determination of Vtg was evaluated by a standard addition method performed in fish serum samples.  相似文献   

8.
A novel strategy for the fabrication of sensitive immunosensor to detect alpha-fetoprotein (AFP) in human serum has been proposed. The immunosensor was prepared by immobilizing AFP antigen onto the glassy carbon electrode (GC) modified by gold nanoparticles and carbon nanotubes doped chitosan (GNP/CNT/Ch) film. GNP/CNT hybrids were produced by one-step synthesis based on the direct redox reaction. The electrochemical properties of GNP/CNT/Ch films were characterized by impedance spectroscopy and cyclic voltammetry. It was indicated that GNP/CNT nanohybrid acted as an electron promoter and accelerated the electron transfer. Sample AFP, immobilized AFP, and alkaline phosphatase (ALP)-labeled antibody were incubated together for the determination based on a competitive immunoassay format. After the immunoassay reaction, the bound ALP label on the modified GC led to an amperometric response of 1-naphthyl phosphate (1-NP), which was changed with the different antigen concentrations in solution. Under the optimized experimental conditions, the resulting immunosensor could detect AFP in a linear range from 1 to 55 ng ml(-1) with a detection limit of 0.6 ng ml(-1). The proposed immunosensor, by using GNP/CNT/Ch as the immobilization matrix of AFP, offers an excellent amperometric response of ALP-anti-AFP to 1-NP. The immunosensor provided a new alternative to the application of other antigens or other bioactive molecules.  相似文献   

9.
A novel experimental methodology for studying a mediatorless and label-free immunosensor is proposed by immobilizing antibody on gold nanoparticle/L-cysteine coated electrode (nano-Au/L-cysteine electrode). Differential pulse voltammograms (DPV) resulting from the assembled immunosensor indicate that the immunosensor shows excellent electrochemical response to dopamine so that the electrochemical response is utilized for the signal generation step of the immunosensor. Therefore, by means of unenzymatic-labeling procedure combined with the amperometric detection using dopamine as substrate, the immunological reaction can be detected. After the immunosensor is incubated with h-IgG solution, the access of electrocatalytic behavior center of the immunosensor to dopamine is partly inhibited, which leads to a linear decrease in amperometric response of the immunosensor with h-IgG concentration over a range 0.82-90 ng mL(-1) by DPV.  相似文献   

10.
A micro potentiometric immunosensor based on mixed SAMs wrapped nano-spheres array for the detection of hemoglobin-A1c level is presented in this paper. Nano-spheres array is prepared by wrapping nano-gold particle with mixed SAMs on the surface of micro immunosensor. Mixed SAMs make the nano-gold particles distribute uniformly without aggregation and render the signal less susceptible to noise. Based on this nano-spheres array, antibody is covalently immobilized on the immunosensor surface. The micro immunosensor, consisting of ISFET integrated chip and MEMS electrodes array is applied to measure hemoglobin-A1c level by detecting the concentration of hemoglobin-A1c and hemoglobin simultaneously. The responses of the immunosensor are linear over the concentration range of 166.7-570 ng/ml hemoglobin and 50-170.5 ng/ml HbA1c. Whole blood sample obtained from hospital was also examined using this immunosensor. The low relative deviation shows that this micro immunosensor may provide an alternative tool for the determination of HbA1c level.  相似文献   

11.
An amperometric enzyme-linked immunosensor was developed to detect and quantify levels of Staphylococcus aureus electrically in pure cultures and in foods. The assay was a modification of a 'sandwich' ELISA for the protein A of Staph. aureus, employing catalase-labelled anti-protein A antibody. On addition of hydrogen peroxide to the assay system the catalase released O2 which was monitored using an amperometric oxygen electrode. The rate of current increase was proportional to the antigen concentration (protein A or Staph. aureus). Protein A was detected reliably at 0.1 ng/ml representing a 20-fold increase in sensitivity over the conventional ELISA that used horseradish peroxidase. Pure cultures of Staph. aureus were detected at 10(-3)-10(-4) cfu/ml with the amperometric electrode (cf greater than 10(5)/ml for conventional ELISA). The same level of sensitivity was achieved for inoculated food samples. Low levels of contamination (1 cfu/g) of Staph. aureus were detected after incubation at 37 degrees C for 18 h, and the immunosensor could from the basis of a test for screening and identification of protein A-bearing Staph. aureus in 24 h, although natural variations in protein A content between different strains could make the system unreliable in accurate quantification of cell numbers.  相似文献   

12.
An accurate, simple and rapid immunoassay is demonstrated for the detection of methamphetamine in urine by capillary electrophoresis (CE) with laser-induced fluorescence (LIF). An aminobutyl derivative of methamphetamine was conjugated with proteins, and used as an immunogen to produce antibodies for the assay. The methamphetamine derivative was also labeled with fluorescein isothiocyanate (FITC) to compete with free methamphetamine in the sample for the antibody binding site. Levels of free and antibody-bound FITC-labeled methamphetamine were monitored by performing CE–LIF using an untreated fused-silica column. This competitive immunoassay used antiserum instead of purified antibody or antibody fragment, yet was found to have good precision with a sensitivity of lower than 20 ng/ml. Various antibodies were also screened, and cross-reactivity of anti-MA antibody with methamphetamine analogues were also investigated. The results indicate that CE–LIF-based immunoassay is a powerful tool for the screening and characterization of antibody and may have possible applications in the detection of abused drugs in urine.  相似文献   

13.
A fluorescence-based continuous-flow immunosensor for sensitive, precise, accurate and fast determination of paclitaxel was developed. The sensor utilizes anti-paclitaxel antibody immobilized through its Fc region and crosslinked by dimethylpimelimidate to protein A attached covalently onto the silanized inner walls of a glass capillary column followed by saturation of the paclitaxel-binding sites with rhodamine-labeled paclitaxel. The assay is based on the displacement and detection downstream of the rhodamine-labeled paclitaxel, by a flow-through spectrofluorometer, as a result of the competition with paclitaxel introduced as a pulse into the stream of carrier buffer flowing through the system. The peak height of the fluorescence intensity profile of the displaced rhodamine-labeled paclitaxel was directly proportional to the concentration of paclitaxel applied and was a function of the carrier buffer flow rate. The sensitivity of the immunosensor response ranged from 0.31 relative fluorescence units (RFU)/ng/ml at a flow rate 0.1 ml/min to 0.52 RFU/ng/ml at 1 ml/min, while the lower detection limit ranged from 1 ng/ml at 0.1 ml/min to 4 ng/ml at 1 ml/min. The immunosensor response was very reproducible (RSD=4.8%; n=10) and linear up to 100 ng/ml. The assay time ranged from 2 min at 1 ml/min to 8 min at 0.1 ml/min. A technique developed to resaturate the antigen binding sites of the immobilized antibody with rhodamine-labeled paclitaxel was successful in regenerating the capillary column without affecting its performance, thus enhancing the economic viability of the immunosensor. The immunosensor was successfully applied for the determination of paclitaxel in human plasma.  相似文献   

14.
A novel immunoaffinity column used as an immunosensor for flow-injection chemiluminescent (CL) immunoassay was prepared by immobilizing antibody on carboxylic resin beads. The immunosensor could fast recognize and trap the immunocomplex of horseradish peroxidase (HRP)-labeled antibody and antigen, which was firstly formed with a micro-bubble accelerated pre-incubation process, to produce a sandwich immunocomplex. The HRP introduced in the immunoaffinity column could catalyze the CL reaction to produce enzyme-enhanced emission. With alpha-fetoprotein (AFP) as a mode, a flow-injection CL immunoassay was proposed. The whole assay for one sample, including the pre-incubation and the regeneration of immunoaffinity column, could be performed within 16min. The linear range was 1.0-80ng/ml with a correlation coefficient of 0.998 and a detection limit of 0.1ng/ml at a signal/noise ratio of 3. The intra- and inter-assay coefficients of variation at 20ng/ml AFP were 1.2% and 8.5%, respectively. The storage stability of the immunoaffinity column and the accuracy for sample detection were acceptable. This flexible, sensitive, low-cost, and rapid method is valuable for clinical immunoassay.  相似文献   

15.
A novel amperometric immunosensor for determination of human serum chorionic gonadotrophin (HCG) was constructed by immobilization of HCG with titania sol-gel on a glassy carbon electrode and the direct electrochemistry of horseradish peroxidase (HRP) labeled to HCG antibody (HRP-anti-HCG). The morphologies of the HCG membrane were characterized to be chemically clean, porous and homogeneous. HRP-anti-HCG was functionally conjugated with the immobilized HCG after incubation in phosphate buffer (PBS) containing HRP-anti-HCG. A direct electron transfer of HRP with a rate constant of 1.35+/-0.40 s(-1) was observed at the HRP-anti-HCG-HCG/titania sol-gel membrane modified electrode in 0.1 M PBS pH 7.0. With a competitive mechanism the differential pulse voltammetric peak current of the immobilized HRP decreased linearly with an increasing HCG concentration from 2.5 to 12.5 mIU/ml in the incubation solution. The HCG immunosensor showed a detection limit of 1.4 mIU/ml, a good accuracy and acceptable precision and reproducibility with an intra-assay CV of 4.7% at 5.0 mIU/ml and an inter-assay precision of 8.1% obtained at 10 mIU/ml. The biosensor displayed a good stability in a storage period of 30 days.  相似文献   

16.
A novel multi-channel 2 x 5 model of piezoelectric quartz micro-array immunosensor has been developed for quantitative detection of human chorionic gonadotropin (hCG) in serum or urine samples. Every crystal unit of the fabricated piezoelectric hCG micro-array immunosensor can oscillate independently without interfering each other. A 2 x 5 model of micro-array immunosensor as compared with a one-channel immunosensor can provide eight times higher detection speeds for hCG assay. The anti-hCG antibody is deposited on the gold electrode's surface of 10 MHz quartz AT-cut crystal by self-assembled technique using sulfosuccinimidyl 6-[3'-(2-pyridyldithio) propionamido] hexanoate (Sulfo-LC-SPDP), and serves as an antibody recognizing layer. The highly ordered self-assembled monolayers (SAM) ensure well-controlled surface structure and offer many advantages to the performance of the sensor. Compared with conventional antibody immobilization methods, the amount and the reaction activity of antibody monolayer coated by the SAM binding are bigger than those by the SPA method, and less non-specific binding caused by other analytes in sample is found. Under the optimized experimental conditions, the results showed that micro-array immunosensor quantitatively detected serum or urine hCG in the range of 2.5-500 mIU/ml with high precision (CV<5%); other hormones in human serum and urine did not interfere with the determination markedly. Serum and urine samples of 60 patients were detected by the micro-array immunosensor, and the results agreed well with those given by the commercial radioimmunoassay test kit, with correlation coefficient of 0.92. After regeneration with urea solution the coated immunosensor can be reused five times without appreciable loss of activity.  相似文献   

17.
Label-free detection of bisphenol A based on the impedance measurement was achieved with an impedimetric immunosensor. The immunosensor was fabricated by the covalent bond formation between a polyclonal antibody and a carboxylic acid group functionalized onto a nano-particle comprised conducting polymer. By using a commercial reagent 4,4-bis(4-hydroxyphenyl) valeric acid (BHPVA), which has an analogous structure of BPA, we have prepared the antigen through the conjugation of BHPVA with bovine serum albumin (BSA) and then produced a specific polyclonal antibody. The immobilization of antibody and the interaction between antibody and antigen were studied using quartz crystal microbalance (QCM) and electrochemical impedance spectroscopic (EIS) techniques. The impedance and mass changes due to the specific immuno-interaction at the sensor surface were utilized to detect antigen and bisphenol A (BPA). The immunosensor showed specific recognition of BPA with less interference than 4.5% from other common phenolic compounds. Under an optimized condition, the linear dynamic range of BPA detection was between 1 and 100 ng/ml. The detection limit of bisphenol A was determined to be 0.3+/-0.07 ng/ml. The proposed immunosensor was applied to a human serum sample and the BPA concentration was determined by the standard addition method.  相似文献   

18.
小麦中脱氧雪腐镰刀菌烯醇酶联免疫吸附测定方法的研究   总被引:17,自引:0,他引:17  
用B淋巴细胞杂交瘤技术制备了能稳定分泌抗脱氧雪腐镰刀菌烯醇(DON)单克隆抗体的杂交瘤细胞株,命名为3D7.3D7的亚类为lgG_1.运用该抗体,建立了检测小麦中DON的间接竞争性酶联免疫吸附测定法.该法最低检出量为5ng/ml,敏感范围为5—1000ng/ml;平均回收率为96.6—107.3%;精密度为6.2—13.3%.运用该方法,检测了10份小麦样品.均为阳性,其含量为56.4—1002.0ppb.  相似文献   

19.
An amperometric immunosensor was fabricated for the detection of osteoproteogerin (OPG) by covalently immobilizing a monoclonal OPG antibody (anti-OPG) onto the gold nanoparticles (AuNPs) deposited functionalized conducting polymer (5,2′:5′,2″-terthiophene-3′-carboxylic acid). AuNPs were electrochemically deposited onto the conducting polymer using cyclic voltammetry. The particle size of deposited AuNPs was controlled by varying the scan rate and was characterized by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The immobilization of anti-OPG was also confirmed using XPS. The principle of immunosensor was based on a competitive immunoassay between free-OPG and labeled-OPG for the active sites of anti-OPG. HRP was used as a label that electrochemically catalyzes the H2O2 reduction. The catalytic reduction was monitored amperometrically at −0.4 V vs. Ag/AgCl. The immunosensor showed a linear range between 2.5 and 25 pg/ml and the detection limit was determined to be 2 pg/ml. The proposed immunosensor was successfully applied for real human samples to detect OPG.  相似文献   

20.
An ion-sensitive field effect transistor (ISFET)-based immunosensor was developed to detect/quantitate beta-Bungarotoxin (beta-BuTx), a potent presynaptic neurotoxin from the venom of Bungarus multicinctus. A murine monoclonal antibody (mAb 15) specific to beta-BuTx was immobilized onto silicon nitride wafers after silanization and activation with glutaraldehyde. A chip based enzyme linked-immunosorbantassay (ELISA) was performed to ascertain antigen binding to the immobilized antibody. To develop an electrochemical immunosensing system for the detection/quantitation of beta-BuTx, an ISFET was used as a solid phase detector. MAb 15 was immobilized on the gate region of the ISFET. The antigen antibody reaction was monitored by the addition of urease conjugated rabbit anti-beta-BuTx antibodies. The sensor can detect toxin level as low as 15.6 ng/ml. The efficacy of the sensor for the determination of beta-BuTx from B. multicinctus venom was demonstrated in mouse model. Toxin concentration was highest at the site of injection (748.0+/-26 ng/ml) and moderate amount was found in the plasma (158.5+/-13 ng/ml).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号