1.
The soft-tissue interface between skin-mounted markers and the underlying bones poses a major limitation to accurate, non-invasive measurement of joint kinematics. The aim of this study was twofold: first, to quantify lower limb soft-tissue artifact in young healthy subjects during functional activity; and second, to determine the effect of soft-tissue artifact on the calculation of knee joint kinematics. Subject-specific bone models generated from magnetic resonance imaging (MRI) were used in conjunction with X-ray images obtained from single-plane fluoroscopy to determine three-dimensional knee joint kinematics for four separate tasks: open-chain knee flexion, hip axial rotation, level walking, and a step-up. Knee joint kinematics was derived using the anatomical frames from the MRI-based, 3D bone models together with the data from video motion capture and X-ray fluoroscopy. Soft-tissue artifact was defined as the degree of movement of each marker in the anteroposterior, proximodistal and mediolateral directions of the corresponding anatomical frame. A number of different skin-marker clusters (total of 180) were used to calculate knee joint rotations, and the results were compared against those obtained from fluoroscopy. Although a consistent pattern of soft-tissue artifact was found for each task across all subjects, the magnitudes of soft-tissue artifact were subject-, task- and location-dependent. Soft-tissue artifact for the thigh markers was substantially greater than that for the shank markers. Markers positioned in the vicinity of the knee joint showed considerable movement, with root mean square errors as high as 29.3 mm. The maximum root mean square errors for calculating knee joint rotations occurred for the open-chain knee flexion task and were 24.3°, 17.8° and 14.5° for flexion, internal–external rotation and abduction–adduction, respectively. The present results on soft-tissue artifact, based on fluoroscopic measurements in healthy adult subjects, may be helpful in developing location- and direction-specific weighting factors for use in global optimization algorithms aimed at minimizing the effects of soft-tissue artifact on calculations of knee joint rotations.  相似文献   

2.
Two-dimensional dynamic modelling of human knee joint   总被引:1,自引:0,他引:1  
A mathematical dynamic model of the two-dimensional representation of the knee joint is presented. The profiles of the joint surfaces are determined from X-ray films and they are represented by polynomials. The joint ligaments are modelled as nonlinear elastic springs of realistic stiffness properties. Nonlinear equations of motion coupled with nonlinear constraint conditions are solved numerically. Time derivatives are approximated by Newmark difference formulae and the resulting nonlinear algebraic equations are solved employing the Newton-Raphson iteration scheme. Several dynamic loads are applied to the center of mass of the tibia and the ensuing motion is investigated. Numerical results on ligament forces, contact point locations between femur and tibia, and the orientation of tibia relative to femur are presented. The results are shown to be consistent with the anatomy of the knee joint.  相似文献   

3.
The inclusion of muscle forces into the analysis of joint contact forces has improved their accuracy. But it has not been validated if such force and activity calculations are valid during highly dynamic multidirectional movements. The purpose of this study was to validate calculated muscle activation of a lower extremity model with a spherical knee joint for running, sprinting and 90°-cutting. Kinematics, kinetics and lower limb muscle activation of ten participants were investigated in a 3D motion capture setup including EMG. A lower extremity rigid body model was used to calculate the activation of these muscles with an inverse dynamics approach and a cubic cost function. Correlation coefficients were calculated to compare measured and calculated activation. The results showed good correlation of the modelled and calculated data with a few exceptions. The highest average correlations were found during walking (r = 0.81) and the lowest during cutting (r = 0.57). Tibialis anterior had the lowest average correlation (r = 0.33) over all movements while gastrocnemius medius had the highest correlation (r = 0.9). The implementation of a spherical knee joint increased the agreement between measured and modelled activation compared to studies using a hinge joint knee. Although some stabilizing muscles showed low correlations during dynamic movements, the investigated model calculates muscle activity sufficiently.  相似文献   

4.
Biomechanics of the knee during stair-ascent has mostly been studied using skin-marker-based motion analysis techniques, but no study has reported a complete assessment of the soft tissue artifacts (STA) and their effects on the calculated joint center translation, angles and moments at the knee in normal subjects during this activity. This study aimed to bridge the gap. Twelve young adults walked up a three-step stair while data were acquired simultaneously from a three-dimensional motion capture system, a force plate and a dynamic fluoroscopy system. The "gold standards" of poses of the knee were obtained using a 3D fluoroscopy method. The STA of the markers on the thigh and shank were then calculated, together with their effects on the calculated joint center translations, angles and moments at the knee. The STA of the thigh markers were greater than those on the shank, leading to significantly underestimated flexion and extensor moments, but overestimated joint center translations during the first half of the stance phase. The results will be useful for a better understanding of the normal biomechanics of the knee during stair-ascent, as a baseline for future clinical applications and for developing a compensation method to correct for the effects of STA.  相似文献   

5.
Shoulder motion is complex and significant research efforts have focused on measuring glenohumeral joint motion. Unfortunately, conventional motion measurement techniques are unable to measure glenohumeral joint kinematics during dynamic shoulder motion to clinically significant levels of accuracy. The purpose of this study was to validate the accuracy of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics. We have developed a model-based tracking technique for accurately measuring in vivo joint motion from biplane radiographic images that tracks the position of bones based on their three-dimensional shape and texture. To validate this technique, we implanted tantalum beads into the humerus and scapula of both shoulders from three cadaver specimens and then recorded biplane radiographic images of the shoulder while manually moving each specimen's arm. The position of the humerus and scapula were measured using the model-based tracking system and with a previously validated dynamic radiostereometric analysis (RSA) technique. Accuracy was reported in terms of measurement bias, measurement precision, and overall dynamic accuracy by comparing the model-based tracking results to the dynamic RSA results. The model-based tracking technique produced results that were in excellent agreement with the RSA technique. Measurement bias ranged from -0.126 to 0.199 mm for the scapula and ranged from -0.022 to 0.079 mm for the humerus. Dynamic measurement precision was better than 0.130 mm for the scapula and 0.095 mm for the humerus. Overall dynamic accuracy indicated that rms errors in any one direction were less than 0.385 mm for the scapula and less than 0.374 mm for the humerus. These errors correspond to rotational inaccuracies of approximately 0.25 deg for the scapula and 0.47 deg for the humerus. This new model-based tracking approach represents a non-invasive technique for accurately measuring dynamic glenohumeral joint motion under in vivo conditions. The model-based technique achieves accuracy levels that far surpass all previously reported non-invasive techniques for measuring in vivo glenohumeral joint motion. This technique is supported by a rigorous validation study that provides a realistic simulation of in vivo conditions and we fully expect to achieve these levels of accuracy with in vivo human testing. Future research will use this technique to analyze shoulder motion under a variety of testing conditions and to investigate the effects of conservative and surgical treatment of rotator cuff tears on dynamic joint stability.  相似文献   

6.
Despite recent attention in the literature, anterior cruciate ligament (ACL) injury mechanisms are controversial and incidence rates remain high. One explanation is limited data on in vivo ACL strain during high-risk, dynamic movements. The objective of this study was to quantify ACL strain during jump landing. Marker-based motion analysis techniques were integrated with fluoroscopic and magnetic resonance (MR) imaging techniques to measure dynamic ACL strain non-invasively. First, eight subjects' knees were imaged using MR. From these images, the cortical bone and ACL attachment sites of the tibia and femur were outlined to create 3D models. Subjects underwent motion analysis while jump landing using reflective markers placed directly on the skin around the knee. Next, biplanar fluoroscopic images were taken with the markers in place so that the relative positions of each marker to the underlying bone could be quantified. Numerical optimization allowed jumping kinematics to be superimposed on the knee model, thus reproducing the dynamic in vivo joint motion. ACL length, knee flexion, and ground reaction force were measured. During jump landing, average ACL strain peaked 55±14 ms (mean and 95% confidence interval) prior to ground impact, when knee flexion angles were lowest. The peak ACL strain, measured relative to its length during MR imaging, was 12±7%. The observed trends were consistent with previously described neuromuscular patterns. Unrestricted by field of view or low sampling rate, this novel approach provides a means to measure kinematic patterns that elevate ACL strains and that provide new insights into ACL injury mechanisms.  相似文献   

7.
This review describes the anatomy of the articular surfaces and their movement in the normal tibio-femoral joint, together with methods of measurement in volunteers. Forces and soft tissues are excluded. To measure movement, the articular surfaces and natural or inserted movement markers must be imaged by some combination of MRI, CT, RSA or fluoroscopy. With the aid of computer-imaging, the movements can then be related to an anatomy-based co-ordinate system to avoid kinematic cross-talk. Methods of depicting these movements which are understandable to engineers and clinicians are discussed. The shapes of the articular surfaces are reported. They are relevant to landmarks and co-ordinate systems and form a basis for inferring the nature of the movements which take place in the knee. The movements of the condyles are described from hyperextension to full passive flexion. Medially the condyle hardly moves antero-posteriorly from 0 degrees to 120 degrees but the contact area transfers from an anterior pair of tibio-femoral surfaces at 10 degrees to a posterior pair at about 30 degrees . Thus because of the shapes of the bones, the medial contact area moves backwards with flexion to 30 degrees but the condyle does not. Laterally the femoral condyle and the contact area move posteriorly but to a variable extent in the mid-range causing tibial internal rotation to occur with flexion around a medial axis. From 120 degrees to full flexion both condyles roll back onto the posterior horn so that the tibio-femoral joint subluxes.  相似文献   

8.
This study demonstrates the validity of using 3-D video motion analysis to measure hand motion. Several researchers have devised ingenious methods to study normal and abnormal hand movements. Although very helpful, these earlier studies are static representations of a dynamic phenomenon. Despite the many studies of hand motion using scientifically impeccable techniques, little is known about digital motion, and there are still few researchers investigating dynamic three-dimensional motion of the hand. Results from a three-camera video motion analysis system were compared to those from the "gold standard", 2-D lateral view fluoroscopy. We used these two methods to record hand motion simultaneously during unrestricted flexion and extension of the index finger of the dominant hand in 6 neurologically normal, healthy volunteers. After collection and post-processing, the waveforms of the PIP, DIP and MCP joint angles were compared using the adjusted coefficient of multiple determination (R2(a), or CMD). The mean CMD values for the MCP, PIP and DIP joint angle waveforms were 0.96, 0.98 and 0.94, respectively, suggesting a close similarity between motion of comparable joints analyzed by the 2-D and 3-D methods. This shows that the method of 3-D motion analysis is capable of accurately quantifying digital joint motion. It is anticipated that 3-D motion analysis, in addition to being used as a research tool, will also have clinical applications such as surgical planning in neuromuscular disorders and the documentation of abnormal motion in many other pathological hand conditions.  相似文献   

9.
Lateral ankle sprains are common injuries in quick, dynamic movements and are caused by rapid ankle inversion. Ankle braces are used to reduce ankle inversion, while allowing normal plantar and dorsiflexion ranges of motion. Knee injuries, such as anterior cruciate ligament injuries, are also common in dynamic movements. It is important to understand how ankle braces affect injury risk at other proximal joints. There is limited and conflicting results on how ankle braces affect knee mechanics during these types of movements. Additionally, it is unknown if sex differences exist when using an ankle brace. Therefore, the purpose of this study was to determine the effects of a hinged ankle brace and sex during a 45° cutting movement. Three-dimensional kinematics and ground reaction forces were collected using a motion capture system and force plate on ten men and eight women during cutting trials. 2 × 2 repeated measures ANOVAs were used to detect differences in ground reaction forces, as well as knee and ankle kinematics between brace conditions and sex (p < 0.05). The brace condition exhibited greater initial contact ankle dorsiflexion (p = 0.011), decreased peak ankle inversion (p < 0.01), and increased vertical loading rate (p = 0.040). Females performed the cutting movement with less initial contact (p = 0.019) and peak knee flexion (p = 0.023) compared to males. Ankle bracing had no impact on the observed sex differences. Females exhibited decreased knee flexion compared to males, which has been well documented in the literature. The use of an ankle braces reduced ankle injury risk variables while not adversely impacting knee mechanics during a 45° sidecutting movement.  相似文献   

10.
Patellofemoral osteoarthritis and its potential precursor patellofemoral pain syndrome (PFPS) are common, costly, and debilitating diseases. PFPS has been shown to be associated with altered patellofemoral joint mechanics; however, an actual variation in joint contact stresses has not been established due to challenges in accurately quantifying in vivo contact kinematics (area and location). This study developed and validated a method for tracking dynamic, in vivo cartilage contact kinematics by combining three magnetic resonance imaging (MRI) techniques, cine-phase contrast (CPC), multi-plane cine (MPC), and 3D high-resolution static imaging. CPC and MPC data were acquired from 12 healthy volunteers while they actively extended/flexed their knee within the MRI scanner. Since no gold standard exists for the quantification of in vivo dynamic cartilage contact kinematics, the accuracy of tracking a single point (patellar origin relative to the femur) represented the accuracy of tracking the kinematics of an entire surface. The accuracy was determined by the average absolute error between the PF kinematics derived through registration of MPC images to a static model and those derived through integration of the CPC velocity data. The accuracy ranged from 0.47 mm to 0.77 mm for the patella and femur and from 0.68 mm to 0.86 mm for the patellofemoral joint. For purely quantifying joint kinematics, CPC remains an analytically simpler and more accurate (accuracy <0.33 mm) technique. However, for application requiring the tracking of an entire surface, such as quantifying cartilage contact kinematics, this combined imaging approach produces accurate results with minimal operator intervention.  相似文献   

11.
Rotator cuff tears are a common injury that affect a significant percentage of the population over age 60. Although it is widely believed that the rotator cuff's primary function is to stabilize the humerus against the glenoid during shoulder motion, accurately measuring the three-dimensional (3D) motion of the shoulder's glenohumeral joint under in-vivo conditions has been a challenging endeavor. In particular, conventional motion measurement techniques have frequently been limited to static or two-dimensional (2D) analyses, and have suffered from limited or unknown in-vivo accuracy. We have recently developed and validated a new model-based tracking technique that is capable of accurately measuring the 3D position and orientation of the scapula and humerus from biplane X-ray images. Herein we demonstrate the in-vivo application of this technique for accurately measuring glenohumeral joint translations during shoulder motion in the repaired and contralateral shoulders of patients following rotator cuff repair. Five male subjects were tested at 3-4 months following arthroscopic rotator cuff repair. Superior-inferior humeral translation was measured during elevation, and anterior-posterior humeral translation was measured during external rotation in both the repaired and contralateral shoulders. The data failed to detect statistically significant differences between the repaired and contralateral shoulders in superior-inferior translation (p=0.74) or anterior-posterior translation (p=0.77). The measurement technique overcomes the limitations of conventional motion measurement techniques by providing accurate, 3D, in-vivo measures of glenohumeral joint motion during dynamic activities. On-going research is using this technique to assess the effects of conservative and surgical treatment of rotator cuff tears.  相似文献   

12.
Model-based tracking, using CT and biplane fluoroscopy, allows highly accurate quantification of glenohumeral motion and changes in the subacromial space. Previous investigators have used custom-built biplane fluoroscopes designed specifically for kinematic applications, which are available at few institutions and require FDA approval prior to clinical use. The aim of this study was to demonstrate the utility of an off-the-shelf clinical biplane fluoroscope for kinematic applications by validating model-based tracking for measurement of glenohumeral motion using an unmodified clinical system. Biplane images of each shoulder of a cadaver torso were acquired at various joint positions and during simulated movements along anatomical planes of motion. The pose of each humerus and scapula was determined using model-based tracking and compared to a bead-based gold standard. Error due to a temporal-offset between corresponding biplane images, characteristic of clinical biplane systems, was determined by comparison of measured and known relative position of 2 bead clusters of a phantom that was imaged while moved throughout the fluoroscopy image volume. Model-based tracking had global kinematic mean absolute errors of 0.27 mm and 0.29° (static), and 0.22–0.32 mm and 0.12–0.45° (dynamic). Glenohumeral mean absolute errors were 0.39 mm and 0.45° (static), and 0.36–0.42 mm and 0.41–0.48° (dynamic). The temporal-offset was predicted to add errors of 0.06–0.85 mm and 0.05–0.28° for cadaveric trials for the speeds examined. For defined speeds, sub-millimeter and sub-degree kinematic accuracy and precision were achieved using an unmodified clinical biplane fluoroscope for quantification of glenohumeral motion.  相似文献   

13.
Estimating tibiofemoral joint contact forces is important for understanding the initiation and progression of knee osteoarthritis. However, tibiofemoral contact force predictions are influenced by many factors including muscle forces and anatomical representations of the knee joint. This study aimed to investigate the influence of subject-specific geometry and knee joint kinematics on the prediction of tibiofemoral contact forces using a calibrated EMG-driven neuromusculoskeletal model of the knee. One participant fitted with an instrumented total knee replacement walked at a self-selected speed while medial and lateral tibiofemoral contact forces, ground reaction forces, whole-body kinematics, and lower-limb muscle activity were simultaneously measured. The combination of generic and subject-specific knee joint geometry and kinematics resulted in four different OpenSim models used to estimate muscle–tendon lengths and moment arms. The subject-specific geometric model was created from CT scans and the subject-specific knee joint kinematics representing the translation of the tibia relative to the femur was obtained from fluoroscopy. The EMG-driven model was calibrated using one walking trial, but with three different cost functions that tracked the knee flexion/extension moments with and without constraint over the estimated joint contact forces. The calibrated models then predicted the medial and lateral tibiofemoral contact forces for five other different walking trials. The use of subject-specific models with minimization of the peak tibiofemoral contact forces improved the accuracy of medial contact forces by 47% and lateral contact forces by 7%, respectively compared with the use of generic musculoskeletal model.  相似文献   

14.
This study demonstrates the validity of using 3-D video motion analysis to measure hand motion. Several researchers have devised ingenious methods to study normal and abnormal hand movements. Although very helpful, these earlier studies are static representations of a dynamic phenomenon. Despite the many studies of hand motion using scientifically impeccable techniques, little is known about digital motion, and there are still few researchers investigating dynamic three-dimensional motion of the hand. Results from a three-camera video motion analysis system were compared to those from the “gold standard”, 2-D lateral view fluoroscopy. We used these two methods to record hand motion simultaneously during unrestricted flexion and extension of the index finger of the dominant hand in 6 neurologically normal, healthy volunteers. After collection and post-processing, the waveforms of the PIP, DIP and MCP joint angles were compared using the adjusted coefficient of multiple determination (R2a, or CMD). The mean CMD values for the MCP, PIP and DIP joint angle waveforms were 0.96, 0.98 and 0.94, respectively, suggesting a close similarity between motion of comparable joints analyzed by the 2-D and 3-D methods. This shows that the method of 3-D motion analysis is capable of accurately quantifying digital joint motion.

It is anticipated that 3-D motion analysis, in addition to being used as a research tool, will also have clinical applications such as surgical planning in neuromuscular disorders and the documentation of abnormal motion in many other pathological hand conditions.  相似文献   


15.
To understand the mechanical consequences of knee injury requires a detailed analysis of the effect of that injury on joint contact mechanics during activities of daily living. Three-dimensional (3D) knee joint geometric models have been combined with knee joint kinematics to dynamically estimate the location of joint contact during physiological activities—using a weighted center of proximity (WCoP) method. However, the relationship between the estimated WCoP and the actual location of contact has not been defined. The objective of this study was to assess the relationship between knee joint contact location as estimated using the image-based WCoP method, and a directly measured weighted center of contact (WCoC) method during simulated walking. To achieve this goal, we created knee specific models of six human cadaveric knees from magnetic resonance imaging. All knees were then subjected to physiological loads on a knee simulator intended to mimic gait. Knee joint motion was captured using a motion capture system. Knee joint contact stresses were synchronously recorded using a thin electronic sensor throughout gait, and used to compute WCoC for the medial and lateral plateaus of each knee. WCoP was calculated by combining knee kinematics with the MRI-based knee specific model. Both metrics were compared throughout gait using linear regression. The anteroposterior (AP) location of WCoP was significantly correlated with that of WCoC on both tibial plateaus in all specimens (p<0.01, 95% confidence interval of Pearson?s coefficient r>0), but the correlation was not significant in the mediolateral (ML) direction for 4/6 knees (p>0.05). Our study demonstrates that while the location of joint contact obtained from 3D knee joint contact model, using the WCoP method, is significantly correlated with the location of actual contact stresses in the AP direction, that relationship is less certain in the ML direction.  相似文献   

16.
Fluoroscopic image technique, using either a single image or dual images, has been widely applied to measure in vivo human knee joint kinematics. However, few studies have compared the advantages of using single and dual fluoroscopic images. Furthermore, due to the size limitation of the image intensifiers, it is possible that only a portion of the knee joint could be captured by the fluoroscopy during dynamic knee joint motion. In this paper, we presented a systematic evaluation of an automatic 2D-3D image matching method in reproducing spatial knee joint positions using either single or dual fluoroscopic image techniques. The data indicated that for the femur and tibia, their spatial positions could be determined with an accuracy and precision less than 0.2?mm in translation and less than 0.4° in orientation when dual fluoroscopic images were used. Using single fluoroscopic images, the method could produce satisfactory accuracy in joint positions in the imaging plane (in average up to 0.5?mm in translation and 1.3° in rotation), but large variations along the out-plane direction (in average up to 4.0?mm in translation and 2.2° in rotation). The precision of using single fluoroscopic images to determine the actual knee positions was worse than its accuracy obtained. The data also indicated that when using dual fluoroscopic image technique, if the knee joint outlines in one image were incomplete by 80%, the algorithm could still reproduce the joint positions with high precisions.  相似文献   

17.
The purpose of the present study was to determine the day-to-day reliability in stride characteristics in rats during treadmill walking obtained with two-dimensional (2D) motion capture. Kinematics were recorded from 26 adult rats during walking at 8 m/min, 12 m/min and 16 m/min on two separate days. Stride length, stride time, contact time, swing time and hip, knee and ankle joint range of motion were extracted from 15 strides. The relative reliability was assessed using intra-class correlation coefficients (ICC(1,1)) and (ICC(3,1)). The absolute reliability was determined using measurement error (ME). Across walking speeds, the relative reliability ranged from fair to good (ICCs between 0.4 and 0.75). The ME was below 91 mm for strides lengths, below 55 ms for the temporal stride variables and below 6.4° for the joint angle range of motion. In general, the results indicated an acceptable day-to-day reliability of the gait pattern parameters observed in rats during treadmill walking. The results of the present study may serve as a reference material that can help future intervention studies on rat gait characteristics both with respect to the selection of outcome measures and in the interpretation of the results.  相似文献   

18.
Despite significant advances in scaffold design, manufacture, and development, it remains unclear what forces these scaffolds must withstand when implanted into the heavily loaded environment of the knee joint. The objective of this study was to fully quantify the dynamic contact mechanics across the tibial plateau of the human knee joint during gait and stair climbing. Our model consisted of a modified Stanmore knee simulator (to apply multi-directional dynamic forces), a two-camera motion capture system (to record joint kinematics), an electronic sensor (to record contact stresses on the tibial plateau), and a suite of post-processing algorithms. During gait, peak contact stresses on the medial plateau occurred in areas of cartilage–cartilage contact; while during stair climb, peak contact stresses were located in the posterior aspect of the plateau, under the meniscus. On the lateral plateau, during gait and in early stair-climb, peak contact stresses occurred under the meniscus, while in late stair-climb, peak contact stresses were experienced in the zone of cartilage–cartilage contact. At 45% of the gait cycle, and 20% and 48% of the stair-climb cycle, peak stresses were simultaneously experienced on both the medial and lateral compartment, suggesting that these phases of loading warrant particular consideration in any simulation intended to evaluate scaffold performance. Our study suggests that in order to design a scaffold capable of restoring ‘normal’ contact mechanics to the injured knees, the mechanics of the intended site of implantation should be taken into account in any pre-clinical testing regime.  相似文献   

19.
The use of magnetic resonance imaging has been proposed by many investigators for establishment of joint reference systems and kinematic tracking of musculoskeletal joints. In this study, the intraobserver and interobserver reliability of a strategy to establish anatomic reference systems using manually selected fiducial points were quantified for seven sets of MR images of the human knee joint. The standard error of the measurement of the intraobserver and interobserver errors were less than 2.6 degrees, and 1.2 mm for relative tibiofemoral orientation and displacement, respectively. An automated motion tracking algorithm was also validated with a controlled motion experiment in a cadaveric knee joint. The controlled displacements and rotations prescribed in our motion tracking validation were highly correlated to those predicted (Pearson's correlation = 0.99, RMS errors = 0.39 mm, 0.38 degree). Finally, the system for anatomic reference system definition and motion tracking was demonstrated with a set of MR images of in vivo passive flexion in the human knee.  相似文献   

20.
The accuracy of estimating the relative pose between knee replacement components, in terms of clinical motion, is important in the study of knee joint kinematics. The objective of this study was to determine the accuracy of the single-plane fluoroscopy method in calculating the relative pose between the femoral component and the tibial component, along knee motion axes, while the components were in motion relative to one another. The kinematics of total knee replacement components were determined in vitro using two simultaneous methods: single-plane fluoroscopic shape matching and an optoelectronic motion tracking system. The largest mean differences in relative pose between the two methods for any testing condition were 2.1°, 0.3°, and 1.1° in extension, abduction, and internal rotation respectively, and 1.3, 0.9, and 1.9 mm in anterior, distal, and lateral translations, respectively. For the optimized position of the components during dynamic trials, the limits of agreement, between which 95% of differences can be expected to fall, were -2.9 to 4.5° in flexion, -0.9 to 1.5° in abduction, -2.4 to 2.1° in external rotation, -2.0 to 3.9 mm in anterior-posterior translation, -2.2 to 0.4mm in distal-proximal translation and -7.2 to 8.6mm in medial-lateral translation. These mean accuracy values and limits of agreement can be used to determine whether the shape-matching approach using single-plane fluoroscopic images is sufficiently accurate for an intended motion tracking application.  相似文献   