首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The patch clamp method measures membrane currents at very high resolution when a high-resistance 'gigaseal' is established between the glass microelectrode and the cell membrane (Pflugers Arch. 391 (1981) 85; Neuron 8 (1992) 605). Here we describe the first use of the silicone elastomer, poly(dimethylsiloxane) (PDMS), for patch clamp electrodes. PDMS is an attractive material for patch clamp recordings. It has low dielectric loss and can be micromolded (Annu. Rev. Mat. Sci. 28 (1998) 153) into a shape that mimics the tip of the glass micropipette. Also, the surface chemistry of PDMS may be altered to mimic the hydrophilic nature of glass (J. Appl. Polym. Sci. 14 (1970) 2499; Annu. Rev. Mat. Sci. 28 (1998) 153), thereby allowing a high-resistance seal to a cell membrane. We present a planar electrode geometry consisting of a PDMS partition with a small aperture sealed between electrode and bath chambers. We demonstrate that a planar PDMS patch electrode, after oxidation of the elastomeric surface, permits patch clamp recording on Xenopus oocytes. Our results indicate the potential for high-throughput patch clamp recording with a planar array of PDMS electrodes.  相似文献   

2.
Biologically inert elastomers such as silicone are favorable materials for medical device fabrication, but forming and curing these elastomers using traditional liquid injection molding processes can be an expensive process due to tooling and equipment costs. As a result, it has traditionally been impractical to use liquid injection molding for low-cost, rapid prototyping applications. We have devised a method for rapid and low-cost production of liquid elastomer injection molded devices that utilizes fused deposition modeling 3D printers for mold design and a modified desiccator as an injection system. Low costs and rapid turnaround time in this technique lower the barrier to iteratively designing and prototyping complex elastomer devices. Furthermore, CAD models developed in this process can be later adapted for metal mold tooling design, enabling an easy transition to a traditional injection molding process. We have used this technique to manufacture intravaginal probes involving complex geometries, as well as overmolding over metal parts, using tools commonly available within an academic research laboratory. However, this technique can be easily adapted to create liquid injection molded devices for many other applications.  相似文献   

3.
A very attractive advantage of manufacturing prosthetic sockets using solid freeform fabrication is the freedom to introduce design solutions that would be difficult to implement using traditional manufacturing techniques. Such is the case with compliant features embedded in amputee prosthetic sockets to relieve contact pressure at the residual limb-socket interface. The purpose of this study was to present a framework for designing compliant features to be incorporated into transtibial sockets and manufacturing prototypes using selective laser sintering (SLS) and Duraform material. The design process included identifying optimal compliant features using topology optimization algorithms and integrating these features within the geometry of the socket model. Using this process, a compliant feature consisting of spiral beams and a supporting external structure was identified. To assess its effectiveness in reducing residual limb-socket interface pressure, a case study was conducted using SLS manufactured prototypes to quantify the difference in interface pressure while a patient walked at his self-selected pace with one noncompliant and two different compliant sockets. The pressure measurements were performed using thin pressure transducers located at the distal tibia and fibula head. The measurements revealed that the socket with the greatest compliance reduced the average and peak pressure by 22% and 45% at the anterior side distal tibia, respectively, and 19% and 23% at the lateral side of the fibula head, respectively. These results indicate that the integration of compliant features within the socket structure is an effective way to reduce potentially harmful contact pressure and increase patient comfort.  相似文献   

4.
Recent progress in tissue engineering has made it possible to build contractile bio-hybrid materials that undergo conformational changes by growing a layer of cardiac muscle on elastic polymeric membranes. Further development of such muscular thin films for building actuators and powering devices requires exploring several design parameters, which include the alignment of the cardiac myocytes and the thickness/Young's modulus of elastomeric film. To more efficiently explore these design parameters, we propose a 3-D phenomenological constitutive model, which accounts for both the passive deformation including pre-stretch and the active behavior of the cardiomyocytes. The proposed 3-D constitutive model is implemented within a finite element framework, and can be used to improve the current design of bio-hybrid thin films and help developing bio-hybrid constructs capable of complex conformational changes.  相似文献   

5.
Capacitive energy harvesters utilizing elastic dielectrics offer a simple way to harvest energy from natural mechanical energy sources. While the technology is promising due to its simplicity and low cost combined with high efficiency and energy density, there are still material challenges that must be addressed. For effective energy conversion, the dielectric material should have low dielectric and mechanical losses, while the compliant electrodes should be able to withstand large strains over an extended lifetime without any substantial loss of conductivity. The development of soft flexible and stretchable silicone–carbon nanotube composite electrodes is presented for use in capacitive energy harvesting and strain sensing. The composite is capable of being stretched to over 150% strain with a minimal increase in the baseline resistance and excellent recovery of electrical properties upon relaxation. The electrode displays excellent strain‐rate stability and is capable of being stretched at a strain rate of 1000% s?1 with only a small increase in resistance. The electrode also displays excellent electrical stability. Applications of the composite electrode include highly stretchable soft capacitors and energy generators. The capacitance change along with stretching could be either linear for sensor purposes or superlinear for improved energy gains as an energy harvester.  相似文献   

6.
Organic thin film transistors (OTFTs) are excellent candidates for the application on disposable sensors due to their potentially low-cost fabrication process. A novel DNA sensor based on OTFTs with semiconducting polymer poly(3-hexylthiophene) has been fabricated by solution process. Both single- and double-strand DNA molecules are immobilized on the surface of the Au source/drain electrodes of different OTFT devices, producing a dramatic change in the performance of the devices, which is attributed to the increase of the contact resistances at the source/drain electrodes. Single-strand DNA and double-strand DNA are differentiated successfully in the experiments indicating that this is a promising technique for sensing DNA hybridization without labelling.  相似文献   

7.
We present an electrode based on complementary metal oxide semiconductor (CMOS) technology that can be made fully biocompatible and chemically inert using a simple, low-cost and non-specialised process. Since these devices are based on ubiquitous CMOS technology, the integrated circuits can be readily developed to include appropriate amplifiers, filters and wireless subsystems, thus reducing the complexity and cost of external systems. The unprocessed CMOS aluminium electrodes are modified using anodisation and plating techniques which do not require intricate and expensive semiconductor processing equipment and can be performed on the bench-top as a clean-room environment is not required. The resulting transducers are able to detect both the fast electrical activity of neurons and the slow changes in impedance of growing and dividing cells. By using standard semiconductor fabrication techniques and well-established technologies, the approach can form the basis of cell-based biosensors and transducers for high throughput drug discovery assays, neuroprosthetics and as a basic research tool in biosciences. The technology is equally applicable to other biosensors that require noble metal or nanoporous microelectrodes.  相似文献   

8.
There is presently significant interest in cellular responses to physical forces, and numerous devices have been developed to apply stretch to cultured cells. Many of the early devices were limited by the heterogeneity of deformation of cells in different locations and by the high degree of anisotropy at a particular location. We have therefore developed a system to impose cyclic, large-strain, homogeneous stretch on a multiwell surface-treated silicone elastomer substrate plated with pulmonary epithelial cells. The pneumatically driven mechanism consists of four plates each with a clamp to fix one edge of the cruciform elastomer substrate. Four linear bearings set at predetermined angles between the plates ensure a constant ratio of principal strains throughout the stretch cycle. We present the design of the device and membrane shape, the surface modifications of the membrane to promote cell adhesion, predicted and experimental measurements of the strain field, and new data using cultured airway epithelial cells. We present for the first time the relationship between the magnitude of cyclic mechanical strain and the extent of wound closure and cell spreading.  相似文献   

9.
We present highly transparent and conductive silver thin films in a thermally evaporated dielectric/metal/dielectric (DMD) multilayer architecture as top electrode for efficient small molecule organic solar cells. DMD electrodes are frequently used for optoelectronic devices and exhibit excellent optical and electrical properties. Here, we show that ultrathin seed layers such as calcium, aluminum, and gold of only 1 nm thickness strongly influence the morphology of the subsequently deposited silver layer used as electrode. The wetting of silver on the substrate is significantly improved with increasing surface energy of the seed material resulting in enhanced optical and electrical properties. Typically thermally evaporated silver on a dielectric material forms rough and granular layers which are not closed and not conductive below thicknesses of 10 nm. With gold acting as seed layer, the silver electrode forms a continuous, smooth, conductive layer down to a silver thickness of 3 nm. At 7 nm silver thickness such an electrode exhibits a sheet resistance of 19 Ω/□ and a peak transmittance of 83% at 580 nm wavelength, both superior compared to silver electrodes without seed layer and even to indium tin oxide (ITO). Top‐illuminated solar cells using gold/silver double layer electrodes achieve power conversion efficiencies of 4.7%, which is equal to 4.6% observed in bottom‐illuminated reference devices employing conventional ITO. The top electrodes investigated here exhibit promising properties for semitransparent solar cells or devices fabricated on opaque substrates.  相似文献   

10.
The osmotic tissue expander is a new device made of a hydrogel expanding skin that does not require external fillings. Once implanted, it absorbs body fluids, which leads to a gradual swelling of the device. The swelling phase is completed in 6 to 8 weeks and results in skin gain. Different shapes and sizes are available, and the devices can be used in almost every area of the body. Over a 4-year period, the osmotic tissue expander was used in 58 patients in different areas of the body. A round osmotic tissue expander was mainly used in breast reconstruction, and a rectangular expander was used for defect coverage after excision (i.e., of scars and tumors). The mean age of the patients was 49.34 years (range, 4 to 76 years). During the expansion phase, the patients noted only a little discomfort and pain for the first few days. Without a silicone membrane in the first-generation expander, the rate of successful explantation and good final result was 81.5 percent. In a few cases, rapid swelling of the device led to the introduction of a silicone membrane that encloses the expander and leads to a slower, more gradual, and consistent swelling. After introduction of the silicone envelope, the success rate improved to 91 percent. The expander is now used with a silicone membrane in every case. The osmotic tissue expander has many advantages compared with the conventional expander: there is no need for painful external fillings and the risk of external infections is avoided. The expander is 10 percent of its final volume and only requires a short incision and a small pocket. An operation can easily be performed under local anesthesia, with minimal tissue mobilization in older children and compliant patients.  相似文献   

11.
Numerous physical characterizations clearly demonstrate that the polypentapeptide of elastin (Val1-Pro2-Gly3-Val4-Gly5)n in water undergoes an inverse temperature transition. Increase in order occurs both intermolecularly and intramolecularly on raising the temperature from 20 to 40 degrees C. The physical characterizations used to demonstrate the inverse temperature transition include microscopy, light scattering, circular dichroism, the nuclear Overhauser effect, temperature dependence of composition, nuclear magnetic resonance (NMR) relaxation, dielectric relaxation, and temperature dependence of elastomer length. At fixed extension of the cross-linked polypentapeptide elastomer, the development of elastomeric force is seen to correlate with increase in intramolecular order, that is, with the inverse temperature transition. Reversible thermal denaturation of the ordered polypentapeptide is observed with composition and circular dichroism studies, and thermal denaturation of the crosslinked elastomer is also observed with loss of elastomeric force and elastic modulus. Thus, elastomeric force is lost when the polypeptide chains are randomized due to heating at high temperature. Clearly, elastomeric force is due to nonrandom polypeptide structure. In spite of this, elastomeric force is demonstrated to be dominantly entropic in origin. The source of the entropic elastomeric force is demonstrated to be the result of internal chain dynamics, and the mechanism is called the librational entropy mechanism of elasticity. There is significant application to the finding that elastomeric force develops due to an inverse temperature transition. By changing the hydrophobicity of the polypeptide, the temperature range for the inverse temperature transition can be changed in a predictable way, and the temperature range for the development of elastomeric force follows. Thus, elastomers have been prepared where the development of elastomeric force is shifted over a 40 degrees C temperature range from a midpoint temperature of 30 degrees C for the polypentapeptide to 10 degrees C by increasing hydrophobicity with addition of a single CH2 moiety per pentamer and to 50 degrees C by decreasing hydrophobicity.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

12.
Details are presented for the formulation, fabrication, and mechanical characterization of mesoscopic freestanding polydimethylsiloxane (PDMS) elastomer membranes, 10.0 μm thick and 5.0 mm in diameter, used to probe the rheology of a living epithelial sheet. In what is described as a composite diaphragm inflation (CDI) experiment, freestanding PDMS membranes are utilized as substrates for the culture of a sheet of epithelial cells. Together, the cell layer and the PDMS elastomer form a composite diaphragm (CD) that is suitable for mechanical testing in an axisymmetric membrane inflation experiment. In order to distinguish the rheological behavior of the epithelial sheet from the mechanical response of the elastomer using inflation test data, freestanding PDMS membranes should exhibit a highly compliant yet mechanically invariant finite load-deformation response when subjected to multiple inflation cycles following intermittent periods of cell culture. Given these considerations, we describe a method for preparing freestanding PDMS elastomer membrane specimens that are optically transparent, tensed, and wrinkle-free. Surface modifications intended to facilitate cell culture, namely water vapor plasma and ultraviolet light treatments, were shown to dramatically stiffen the mechanical response of the membranes, rendering them unusable as CD substrates. In this study, only PDMS membranes with physiosorbed collagen demonstrated the mechanical compliance, fatigue resistance, and environmental stability necessary for reliable use in CDI experiments.  相似文献   

13.
Recent advances in the development of electronic technologies and biomedical devices offer opportunities for non-invasive, quantitative assessment of cutaneous wound healing on the skin. Existing methods, however, still rely on visual inspections through various microscopic tools and devices that normally include high-cost, sophisticated systems and require well trained personnel for operation and data analysis. Here, we describe methods and protocols to fabricate a conformal, skin-like electronics system that enables conformal lamination to the skin surface near the wound tissues, which provides recording of high fidelity electrical signals such as skin temperature and thermal conductivity. The methods of device fabrication provide details of step-by-step preparation of the microelectronic system that is completely enclosed with elastomeric silicone materials to offer electrical isolation. The experimental study presents multifunctional, biocompatible, waterproof, reusable, and flexible/stretchable characteristics of the device for clinical applications. Protocols of clinical testing provide an overview and sequential process of cleaning, testing setup, system operation, and data acquisition with the skin-like electronics, gently mounted on hypersensitive, cutaneous wound and contralateral tissues on patients.  相似文献   

14.
Driven by economic and time constraints, some medical centers and third parties are resterilizing single-use devices (SUDs) for reuse. The steam autoclave is quick, but most plastics used in SUDs cannot survive the temperature. Thus, a number of new methods of cleaning, disinfecting, and sterilizing these complex devices are being introduced on the market. The present study investigated the effects of a range of methods on the tensile strength of latex rubber, silicone elastomer, 2 different formulations of polyurethane, nylon, and high-density polyethylene (HDPE) specimens. The methods used were sodium hypochlorite bleach (Clorox), peracetic acid + hydrogen peroxide (Steris), formaldehyde gas (Chemiclave), low-temperature peracetic acid and gas plasma (Plazlyte), and low-temperature hydrogen peroxide gas plasma (Sterrad). The results showed that silicone elastomer was minimally affected, whereas the strengths of nylon, polyethylene, and latex were reduced by some of the methods. Depending on the formulation, the strength of polyurethane either increased or decreased. The data demonstrated that disinfection and sterilization can affect the tensile strength of certain materials used in medical devices.  相似文献   

15.
The annelid provides a biological solution of effective locomotion adaptable to a large variety of unstructured environmental conditions. The undulated locomotion of the segmented body in the annelid is characterized by the combination of individual motion of the muscles distributed along the body, which has been of keen interest in biomimetic investigation. In this paper, we present an annelid-like robot driven by soft actuators based on dielectric elastomer. To mimic the unique motion of the annelid, a novel actuation method employing dielectric elastomer is developed. By using the actuator, a three-degree-of-freedom actuator module is presented, which can provide up-down translational motion, and two rotational degree-of-freedom motion. The proposed actuation method provides advantageous features of reduction in size, fast response and ruggedness in operation. By serially connecting the actuator modules, a micro-robot mimicking the motion of the annelid is developed and its effectiveness is experimentally demonstrated.  相似文献   

16.
Existing methods for picoinjecting reagents into microfluidic drops require metal electrodes integrated into the microfluidic chip. The integration of these electrodes adds cumbersome and error-prone steps to the device fabrication process. We have developed a technique that obviates the needs for metal electrodes during picoinjection. Instead, it uses the injection fluid itself as an electrode, since most biological reagents contain dissolved electrolytes and are conductive. By eliminating the electrodes, we reduce device fabrication time and complexity, and make the devices more robust. In addition, with our approach, the injection volume depends on the voltage applied to the picoinjection solution; this allows us to rapidly adjust the volume injected by modulating the applied voltage. We demonstrate that our technique is compatible with reagents incorporating common biological compounds, including buffers, enzymes, and nucleic acids.  相似文献   

17.
The resonance of surface plasma waves in metallic layers is a strongly polarization-dependent phenomenon by the very nature of the physical effect responsible of that resonance. This implies the necessity of polarization-controlling elements to be added to any operative surface-plasmon-resonance-based sensor. A fully symmetrical, circular-section double deposition of a metallic and a dielectric layer on a uniform-waist tapered optical fiber (SymDL-UWT) permits us to completely eliminate the dependence on polarization of the plasmon excitation, with the corresponding operative advantages and basic theoretical consequences. We depict the fabrication process of these transducers, which is based on the use of a simple and efficient rotating element developed by us, and show the characteristics of the produced devices. No such device has been depicted up to date. As our experimental results show, this kind of devices can be considered a very good option for the development of simple, compact, and efficient chemical and biological sensors.  相似文献   

18.
The use of bio‐nanotechnology for the fabrication of diverse functional nanomaterials with precisely controlled morphologies and microstructures is attracting considerable attention due to its sustainability and renewability. As one of the key energy storage devices, supercapacitor (SC) requires the active electrode material to have high specific surface area, interconnected porous structure, excellent electronic conductivity, and appropriate heteroatom doping for promoting the transfer of electrons and electrolyte ions. The combination of bio‐technology and SC will open up a new avenue for the large‐scale fabrication of high performance functional energy storage devices. In this review, the most state‐of‐the‐art research progress in bio‐nanotechnological fabrication of different nanomaterials, including carbon materials, metal oxides, conducting polymers, and their corresponding composites are reviewed with the following three bio‐nanotechnical approaches covered: (1) biomass carbonization technologies; (2) bio‐template methods; and (3) bio‐complex technologies, while also highlighting their applications as functional SC electrodes.  相似文献   

19.
Biodegradable polymers with high mechanical strength, flexibility and optical transparency, optimal degradation properties and biocompatibility are critical to the success of tissue engineered devices and drug delivery systems. Most biodegradable polymers suffer from a short half-life due to rapid degradation upon implantation, exceedingly high stiffness, and limited ability to functionalize the surface with chemical moieties. This work describes the fabrication of microfluidic networks from poly(ester amide), poly(1,3-diamino-2-hydroxypropane-co-polyol sebacate) (APS), a recently developed biodegradable elastomeric polymer. Microfluidic scaffolds constructed from APS exhibit a much lower Young''s modulus and a significantly longer degradation half-life than those of previously reported systems. The device is fabricated using a modified replica-molding technique, which is rapid, inexpensive, reproducible and scalable, making the approach ideal for both rapid prototyping and manufacturing of tissue engineering scaffolds.Key words: biodegradable, microfluidics, tissue engineering, elastomer, scaffold, polymer  相似文献   

20.
Background  There is considerable interest in developing coitally independent, sustained release formulations for long-term administration of HIV microbicides. Vaginal ring devices are at the forefront of this formulation strategy.
Methods  Non-medicated silicone elastomer vaginal rings were prepared having a range of appropriate dimensions for testing vaginal fit in pig-tailed and Chinese rhesus macaques. Cervicovaginal proinflammatory markers were evaluated. Compression testing was performed to compare the relative flexibility of various macaque and commercial human rings.
Results  All rings remained in place during the study period and no tissue irritation or significant induction of cervicovaginal proinflammatory markers or signs of physical discomfort were observed during the 8-week study period.
Conclusions  Qualitative evaluation suggests that the 25 × 5-mm ring provided optimal fit in both macaque species. Based on the results presented here, low-consistency silicone elastomers do not cause irritation in macaques and are proposed as suitable materials for the manufacture of microbicide-loaded vaginal rings.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏