首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
AIMS: Combinations of PCR primer sets were evaluated to establish a multiplex PCR method to specifically detect Escherichia coli O157:H7 genes in bovine faecal samples. METHODS AND RESULTS: A multiplex PCR method combining three primer sets for the E. coli O157:H7 genes rfbE, uidA and E. coli H7 fliC was developed and tested for sensitivity and specificity with pure cultures of 27 E. coli serotype O157 strains, 88 non-O157 E. coli strains, predominantly bovine in origin and five bacterial strains other than E. coli. The PCR method was very specific in the detection of E. coli O157:H7 and O157:H- strains, and the detection limit in seeded bovine faecal samples was <10 CFU g(-1) faeces, following an 18-h enrichment at 37 degrees C, and could be performed using crude DNA extracts as template. CONCLUSIONS: A new multiplex PCR method was developed to detect E. coli O157:H7 and O157:H-, and was shown to be highly specific and sensitive for these strains both in pure culture and in crude DNA extracts prepared from inoculated bovine faecal samples. SIGNIFICANCE AND IMPACT OF THE STUDY: This new multiplex PCR method is suitable for the rapid detection of E. coli O157:H7 and O157:H- genes in ruminant faecal samples.  相似文献   

2.
AIMS: The fate of Escherichia coli O157:H7 was investigated during the manufacture of Mozzarella cheese. METHODS AND RESULTS: The Mozzarella cheese was made from unpasteurized milk which was inoculated to contain ca 10(5) cfu ml(-1)E. coli O157:H7. Two different heating temperatures (70 and 80 degrees C), commonly used during curd stretching, were investigated to determine their effects on the viability of E. coli O157:H7 in Mozzarella cheese. Stretching at 80 degrees C for 5 min resulted in the loss of culturability of E. coli O157:H7 strains, whereas stretching at 70 degrees C reduced the number of culturable E. coli O157:H7 by a factor of 10. CONCLUSIONS: The results show that stretching curd at 80 degrees C for 5 min is effective in controlling E. coli O157:H7 during the production of Mozzarella cheese. Brining and storage at 4 degrees C for 12 h was less effective than the stretching. Significance and Impact of the Study: Mozzarella cheese should be free of E. coli O157:H7 only if temperatures higher than or equal to 80 degrees C are used during milk processing.  相似文献   

3.
In this study, enrichment procedures and two recovery methods, a membrane surface adhesion technique and an immunomagnetic separation (IMS), were compared for use in conjunction with a multiplex polymerase chain reaction (PCR) method with a view to describing a fast (24 h) and economical test for detection of Escherichia coli O157:H7 in meat samples. The study showed no significant difference between three different enrichment media (BHI, E. coli (E.C.) broth+novobiocin, modified tryptone soya broth (mTSB)+novobiocin) or two incubation temperatures (37 or 41.5 degrees C) for growth of E. coli O157:H7 in minced beef. Minced beef samples inoculated with E. coli O157:H7 at 40 cfu g(-1) were incubated at 37 degrees C for 16 h in E.C. broth+novobiocin reaching numbers of (log(10)7.82-8.70). E. coli O157:H7 were recovered by attachment to polycarbonate membranes immersed in the enriched cultures for 15 min or by immunomagnetic separation. Subsequent treatment of recovered membranes or IMS beads with lysis buffer and phenol/chloroform/isoamyl alcohol was used to extract the DNA from the extracted E. coli O157:H7 cells. The results show when E. coli O157:H7 was present at high levels in the enriched meat sample (log(10)9.6-7.5 cfu ml(-1); >16-h enrichment), the membrane and IMS techniques recovered similar levels of the pathogen and the microorganism was detectable by PCR using both methods. At lower levels of E. coli O157:H7 (log(10)6.4), only the IMS method could recover the pathogen but at levels below this neither method could recover sufficient numbers of the pathogens to allow detection. The conclusion of the study is that with sufficient enrichment time (16 h) the membrane surface adhesion membrane extraction method used in combination with multiplex PCR has the potential for a rapid and economical detection method.  相似文献   

4.
AIM: To develop an improved, rapid and sensitive sample preparation method for PCR-based detection of Escherichia coli O157:H7 in ground beef. METHODS AND RESULTS: Fresh ground beef samples were experimentally inoculated with varying concentrations of E. coli O157:H7. PCR inhibitors were removed and bacterial cells were concentrated by filtration and centrifugation, and lysed using enzymatic digestion and successive freeze/thaw cycles. DNA was purified and concentrated via phenol/chloroform extraction and the Shiga toxin 1 gene (stx1) was amplified using PCR to evaluate the sample preparation method. Without prior enrichment of cells in broth media, the detection limit was 103 CFU g-1 beef. When a 6 h enrichment step was incorporated, the detection limit was 1 CFU g-1 beef. The total time required from beginning to end of the procedure was 12 h. CONCLUSIONS: The sample preparation method developed here enabled substantially improved sensitivity in the PCR-based detection of E. coli O157:H7 in ground beef, as compared to previous reports. SIGNIFICANCE AND IMPACT OF THE STUDY: Superb sensitivity, coupled with quick turn-around time, relative ease of use and cost-effectiveness, makes this a useful method for detecting E. coli O157:H7 in ground beef.  相似文献   

5.
AIMS: To apply the real-time Polymerase chain reaction (PCR) method to detect and quantify Escherichia coli O157:H7 in soil, manure, faeces and dairy waste washwater. METHODS AND RESULTS: Soil samples were spiked with E. coli O157:H7 and subjected to a single enrichment step prior to multiplex PCR. Other environmental samples suspected of harbouring E.coli O157:H7 were also analysed. The sensitivity of the primers was confirmed with DNA from E.coli O157:H7 strain 3081 spiked into soil by multiplex PCR assay. A linear relationship was measured between the fluorescence threshold cycle (C T ) value and colony counts (CFU ml(-1)) in spiked soil and other environmental samples. The detection limit for E.coli O157:H7 in the real-time PCR assay was 3.5 x 10(3) CFU ml(-1) in pure culture and 2.6 x 10(4) CFU g(-1) in the environmental samples. Use of a 16-h enrichment step for spiked samples enabled detection of <10 CFU g(-1) soil. E. coli colony counts as determined by the real-time PCR assay, were in the range of 2.0 x 10(2) to 6.0 x 10(5) CFU PCR (-1) in manure, faeces and waste washwater. CONCLUSIONS: The real-time PCR-based assay enabled sensitive and rapid quantification of E. coli O157:H7 in soil and other environmental samples. SIGNIFICANCE AND IMPACT OF THE STUDY: The ability to quantitatively determine cell counts of E.coli O157:H7 in large numbers of environmental samples, represents considerable advancement in the area of pathogen quantification for risk assessment and transport studies.  相似文献   

6.
Surface water and groundwater are continuously used as sources of drinking water in many metropolitan areas of the United States. The quality of water from these sources may be reduced due to increases in contaminants such as Escherichia coli from urban and agricultural runoffs. In this study, a multiplex fluorogenic PCR assay was used to quantify E. coli O157:H7 in soil, manure, cow and calf feces, and dairy wastewater in an artificial wetland. Primers and probes were designed to amplify and quantify the Shiga-like toxin 1 (stx1) and 2 (stx2) genes and the intimin (eae) gene of E. coli O157:H7 in a single reaction. Primer specificity was confirmed with DNA from 33 E. coli O157:H7 and related strains with and without the three genes. A direct correlation was determined between the fluorescence threshold cycle (C(T)) and the starting quantity of E. coli O157:H7 DNA. A similar correlation was observed between the C(T) and number of CFU per milliliter used in the PCR assay. A detection limit of 7.9 x 10(-5) pg of E. coli O157:H7 DNA ml(-1) equivalent to approximately 6.4 x 10(3) CFU of E. coli O157:H7 ml(-1) based on plate counts was determined. Quantification of E. coli O157:H7 in soil, manure, feces, and wastewater was possible when cell numbers were >/=3.5 x 10(4) CFU g(-1). E. coli O157:H7 levels detected in wetland samples decreased by about 2 logs between wetland influents and effluents. The detection limit of the assay in soil was improved to less than 10 CFU g(-1) with a 16-h enrichment. These results indicate that the developed PCR assay is suitable for quantitative determination of E. coli O157:H7 in environmental samples and represents a considerable advancement in pathogen quantification in different ecosystems.  相似文献   

7.
Direct PCR detection of Escherichia coli O157:H7   总被引:2,自引:0,他引:2  
AIMS: This paper reports a simple, rapid approach for the detection of Shiga toxin (Stx)-producing Escherichia coli (STEC). METHODS AND RESULTS: Direct PCR (DPCR) obviates the need for the recovery of cells from the sample or DNA extraction prior to PCR. Primers specific for Stx-encoding genes stx1 and stx2 were used in DPCR for the detection of E. coli O157:H7 added to environmental water samples and milk. CONCLUSIONS: PCR reactions containing one cell yielded a DPCR product. SIGNIFICANCE AND IMPACT OF THE STUDY: This should provide an improved method to assess contamination of environmental and other samples by STEC and other pathogens.  相似文献   

8.
Primers, specific for a unique base substitution in uidA of Escherichia coli O157:H7, were coupled with oligonucleotides for the shiga-like toxin I (SLT-I) and SLT-II genes in a multiplex PCR assay. A minimum of 10(2) CFU per PCR (10 microliters) was necessary to amplify E. coli O157:H7-specific bands by multiplex PCR. Food particles as well as various unknown metabolic by-products of bacteria inhibited the PCR, but a simple two-step filtration procedure eliminated this inhibition. To reliably generate PCR products, an E. coli inoculum of 10(3) CFU g of food slurry-1 in a nonspecific medium was required with 6 h of enrichment at 37 degrees C. However, when the food homogenate was incubated overnight, E. coli O157:H7 at an initial inoculum of even 1 CFU g-1 was detected.  相似文献   

9.
AIM: To determine the sensitivity of methods for detection of injured and uninjured Escherichia coli O157:H7 (E. coli O157) in raw and pasteurized milk. METHODS AND RESULTS: Raw milk, pasteurized milk with 1.5% fat content and pasteurized milk with 3.5% fat content were spiked with E. coli O157 at low levels. The samples were enriched in modified tryptone soya broth with novobiocin (mTSBn) at 37 degrees C. Aliquots of the enriched culture were analysed either by manual immunomagnetic separation (MIMS) and culturing on sorbitol MacConkey agar with or without cefixime and potassium tellurite (SMACct or SMAC), or by automated immunomagnetic separation and integrated ELISA (EiaFosstrade mark). Uninjured E. coli O157 organisms were detected in milk by both methods at 1 cfu 10 ml-1 sample). Injured organisms were detected at levels of about 4 cfu 10 ml-1 sample. Direct enrichment in mTSBn (22 h incubation) showed better sensitivity for injured cells than enrichment in buffered peptone water (BPW, 22 h incubation), or in a two-step enrichment consisting of BPW (6 h, 37 degrees C) and mTSBn (16 h, 37 degrees C), successively. CONCLUSIONS: The methods showed equal sensitivity in that they were both able to detect 1 cfu 10 ml-1 milk sample. Injured organisms can be detected and isolated at a level almost as low as this. A resuscitation step is not recommended for the detection and isolation of injured and non-injured E. coli O157 from milk. SIGNIFICANCE AND IMPACT OF THE STUDY: Due to the dilution of contamination in the bulk tank, analysis of milk for the presence of E. coli O157 requires a very sensitive method. Both methods described here are useful for such analysis.  相似文献   

10.
AIMS: The behaviour of Escherichia coli O157:H7 was studied during the manufacture and ripening of a smear-ripened cheese produced from raw milk. METHODS AND RESULTS: Cheese was manufactured on a laboratory scale using milk (20 l) inoculated with E. coli O157:H7, and enumeration was carried out using CT-SMAC. From an initial level of 1.52 +/- 0.03 log cfu ml-1 in the milk (34 +/- 2 cfu ml-1), the numbers increased to 3.4 +/- 0.05 log cfu g-1 in the cheese at day 1. During ripening, the numbers decreased to <1 cfu g-1 and <10 cfu g-1 in the rind and core, respectively, after 21 days, although viable cells were detected by enrichment after 90 days. The presence of E. coli O157:H7 in the cheese was confirmed by latex agglutination and by multiplex PCR. CONCLUSION: The results indicate that the manufacturing procedure encouraged substantial growth of E. coli O157:H7 to levels that permitted survival during ripening and extended storage. SIGNIFICANCE AND IMPACT OF THE STUDY: The presence of low numbers of E. coli O157:H7 in milk, destined for raw milk cheese manufacture, could constitute a threat to the consumer.  相似文献   

11.
目的:建立一种real-time PCR,快速准确检测肠出血性大肠杆菌O157:H7。方法:以肠出血性大肠杆菌0157:H7 rfbE为待检靶基因,设计一对引物和一条Taqman探针,探针5’端用FAM基团标记,3’端用TAMRA标记。通过重组质粒的构建,建立并优化了大肠杆菌0157:H7的荧光定量PCR检测方法。结果:在人工污染样本无需富集的情况下,检测的最低DNA浓度是10拷贝/反应(3CFU/mL);特异性检测实验中,0157菌株检测结果均为rfbE阳性,而非0157:H7菌株检测结果均为阴性;重复性实验中,批内、批间变异系数均小于3%。结论:实验结果显示此荧光定量PCR方法特异性、灵敏度高,重复性好,可对分离的可疑大肠杆菌0157:H7菌株进行快速鉴定。  相似文献   

12.
AIMS: To assess the presence of virulence genes in environmental and foodborne Escherichia coli isolates using the TaqMan PCR system. METHODS AND RESULTS: Three TaqMan pathogen detection kits called O157:H7, StxI and StxII were used to investigate the presence of virulence genes in Escherichia coli isolates. All 54 foodborne E. coli O157:H7 isolates showed expected results using these kits. Ninety (15%) of 604 environmental isolates gave positive amplification with an O157:H7-specific kit. TaqMan PCR amplification products from these 90 isolates were analysed by agarose gel electrophoresis, and 90% (81 of 90) of the environmental samples contained the expected PCR product. Sixty-six of these 90 were chosen for serotyping tests and only 35% (23 of 66) showed agglutination with both anti-O157 and anti-H7 antibodies. Further ribotyping of 16 sero-positive isolates in an automated Riboprinter did not identify these to be O157:H7. Multiplex PCR with primers for eaeA, stxI and stxII genes was used to confirm the TaqMan results in 10 selected environmental isolates. CONCLUSIONS: All three TaqMan pathogen detection kits were useful for virulence gene analysis of prescreened foodborne O157:H7 isolates, while the O157:H7-specific kit may not be suitable for virulence gene analysis of environmental E. coli isolates, because of high false positive identification. SIGNIFICANCE AND IMPACT OF THE STUDY: The ability to rapidly identify the presence of pathogenic E. coli in food or environmental samples is essential to avert outbreaks. These results are of importance to microbiologists seeking to use TaqMan PCR to rapidly identify pathogenic E. coli in environmental samples. Furthermore, serotyping may not be a reliable method for identification of O157:H7 strains.  相似文献   

13.
AIMS: To evaluate the suitability of a multiplex PCR-based assay for sensitive and rapid detection of Escherichia coli O157:H7 in soil and water. METHODS AND RESULTS: Soil and water samples were spiked with E. coli O157:H7 and subjected to two stages of enrichment prior to multiplex PCR. Detection sensitivities were as high as 1 cfu ml(-1) drinking water and 2 cfu g(-1) soil. Starvation of E. coli O157:H7 for 35 d prior to addition to soil did not affect the ability of the assay to detect initial cell numbers as low as 10 cfu g(-1) soil. Use of an 8-h primary enrichment enabled detection of as few as 6 cfu g(-1) soil, and 10(4) cfu g(-1) soil with a 6-h primary enrichment. When soil was inoculated with 10(5) cfu g(-1), the PCR assay indicated persistence of E. coli O157:H7 during a 35 d incubation. However, when soil was inoculated with lower numbers of pathogen, PCR amplification signals indicated survival to be dependent on cell concentration. CONCLUSIONS: A multiplex PCR-based assay, in combination with an enrichment strategy enabled sensitive and rapid detection of E. coli O157:H7 in soil and water. SIGNIFICANCE AND IMPACT OF THE STUDY: The ability to sensitively detect E.coli O157:H7 in environmental material within one working day represents a considerable advancement over alternative more time-consuming methods for detection of this pathogen.  相似文献   

14.
A novel assay utilizing immuno-labeling, filtration, and electrochemistry for the rapid detection of bacteria has been optimized for the detection of Escherichia coli O157:H7. Bacteria were specifically labeled with alkaline phosphatase conjugated polyclonal antibodies and captured on a polycarbonate track-etched membrane filter (0.2 microm pore size). The filter was then placed directly against a glassy carbon electrode, incubated with enzyme substrate, and the product detected by square wave voltammetry. The high speed and capture efficiency of membrane filtration and inherent sensitivity of electrochemical detection produced a 25-min assay with a detection limit of 5 x 10(3) E. coli O157:H7 per ml using a filtration volume of 100 microl (i.e. 500 cells filtered). The labeling, filtration, and electrochemical steps were optimized, and the assay performance using electrochemical and colorimetric detection methods was compared. The assay was used to detect E. coli O157:H7 that was spiked into filter-sterilized urine at clinically relevant concentrations.  相似文献   

15.
AIMS: This paper provides identification of a DNA sequence derived from Shiga toxin-producing Escherichia coli (STEC) O157:H7 and information on its utilization for detecting STEC O157 by PCR. METHODS AND RESULTS: Random Amplified Polymorphic DNA and DNA library were used to identify in STEC O157:H7 (strain EDL 933) a 2634-bp Small Inserted Locus, designated SILO157. Analysis of 211 bacterial strains showed that the PCR assays amplifying the SILO157 region could be used to detect STEC O157 with a good specificity. CONCLUSIONS: Characterization of a novel locus in STEC O157 is attractive since the serotype O157:H7 of STEC is still by far the most important serotype associated with more serious diseases. This island encodes putative proteins and especially one that is predicted to be an outer membrane protein designated IHP1. SIGNIFICANCE AND IMPACT OF THE STUDY: Further investigations could now be developed to appreciate the role of the SILO157 in pathogenicity.  相似文献   

16.
A quantitative competitive PCR (QC-PCR) assay was developed to detect and quantify Escherichia coli O157:H7 cells. From 10(3) to 10(8) CFU of E. coli O157:H7 cells/ml was quantified in broth or skim milk, and cell densities predicted by QC-PCR were highly related to viable cell counts (r(2) = 0.99 and 0.93, respectively). QC-PCR has potential for quantitative detection of pathogenic bacteria in foods.  相似文献   

17.
18.
A method for the rapid detection of verotoxin-producing Escherichia coli O157:H7 in stools was evaluated. Strains possessing Shiga toxin-2 (stx-2) genes were isolated from stool samples and amplified using oligonucleotide primers. Stools spiked with cultured E. coli O157:H7 (strain 298 or strain 1646) were detected to be polymerase chain reaction (PCR) positive at 10(2) cfu per 0.1 g of stool. Stool samples from patients and healthy carriers showed a high correlation between positive results for a PCR and the presence of verotoxin-producing E. coli O157:H7, confirmed by isolation of serotype O157:H7 on sorbitol MacConkey medium (10 of 10 stool samples). These PCR products could be detected using a BIAcore 2000 surface plasmon resonance device using peptide nucleic acid as a sensor probe. In this report we use this method for the rapid detection of DNA from significant pathogenic organisms.  相似文献   

19.
Aims:  The major objective of this study was to determine the effects of low levels of Escherichia coli O157:H7 contamination on plant by monitoring the survival of the pathogen on the rhizosphere and leaf surfaces of lettuce during the growth process.
Methods and Results:  Real-time PCR and plate counts were used to quantify the survival of E. coli O157:H7 in the rhizosphere and leaf surfaces after planting. Real-time PCR assays were designed to amplify the stx 1, stx 2 and the eae genes of E. coli O157:H7. The detection limit for E. coli O157:H7 quantification by real-time PCR was 2·4 × 103 CFU g−1 of starting DNA in rhizosphere and phyllosphere samples and about 102 CFU g−1 by plate count. The time for pathogens to reach detection limits on the leaf surface by plate counts was 7 days after planting in comparison with 21 days in the rhizosphere. However, real-time PCR continued to detect stx 1, stx 2 and the eae genes throughout the experimental period.
Conclusion:  Escherichia coli O157:H7 survived throughout the growth period as was determined by real-time PCR and by subsequent enrichment and immunomagnetic separation of edible part of plants.
Significance and impact of the Study:  The potential presence of human pathogens in vegetables grown in soils contaminated with E. coli O157:H7 is a serious problem to our national food supply as the pathogen may survive on the leaf surface as they come in contact with contaminated soil during germination.  相似文献   

20.
AIMS: To evaluate PCR primers for the detection of pathogenic Escherichia coli in a real-time PCR assay and determine their utility in produce irrigation water testing. METHODS AND RESULTS: Three previously published PCR primer sets and one set designed for this study were tested for their ability to produce amplification products for several pathogenic E. coli serotypes from whole cells as template. Two of the previously published primer sets were chosen for real-time PCR detection limit determination. The coneaeA and PEH detection limit of E. coli O157:H7 was 10(0) and 10(1) CFU rxn(-1) in sterile water respectively. To detect E. coli O157:H7 in sprout irrigation water, the water required dilution due to PCR inhibitors. The detection limit of the coneaeA and PEH was 10(1) and between 10(2) and 10(3) CFU rxn(-1) in diluted sprout irrigation water respectively. CONCLUSIONS: The primer set coneaeA was able to produce an amplification product from each E. coli serotype, except O128:H7 and most sensitive for real-time PCR detection of pathogenic E. coli in diluted sprout irrigation water. SIGNIFICANCE AND IMPACT OF THE STUDY: The necessity of a dissociation analysis to distinguish positive samples from those with fluorescence of random dsDNA generation for real-time PCR in a complex background was established.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号