首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel amperometric immunosensor for determination of human serum chorionic gonadotrophin (HCG) was constructed by immobilization of HCG with titania sol-gel on a glassy carbon electrode and the direct electrochemistry of horseradish peroxidase (HRP) labeled to HCG antibody (HRP-anti-HCG). The morphologies of the HCG membrane were characterized to be chemically clean, porous and homogeneous. HRP-anti-HCG was functionally conjugated with the immobilized HCG after incubation in phosphate buffer (PBS) containing HRP-anti-HCG. A direct electron transfer of HRP with a rate constant of 1.35+/-0.40 s(-1) was observed at the HRP-anti-HCG-HCG/titania sol-gel membrane modified electrode in 0.1 M PBS pH 7.0. With a competitive mechanism the differential pulse voltammetric peak current of the immobilized HRP decreased linearly with an increasing HCG concentration from 2.5 to 12.5 mIU/ml in the incubation solution. The HCG immunosensor showed a detection limit of 1.4 mIU/ml, a good accuracy and acceptable precision and reproducibility with an intra-assay CV of 4.7% at 5.0 mIU/ml and an inter-assay precision of 8.1% obtained at 10 mIU/ml. The biosensor displayed a good stability in a storage period of 30 days.  相似文献   

2.
Amperometric choline biosensors were fabricated by the covalent immobilization of an enzyme of choline oxidase (ChO) and a bi-enzyme of ChO/horseradish peroxidase (ChO/HRP) onto poly-5,2′:5′,2″-terthiophene-3′-carboxylic acid (poly-TTCA) modified electrodes (CPMEs). A sensor modified with ChO utilized the oxidation process of enzymatically generated H2O2 in a choline solution at +0.6 V. The other one modified with ChO/HRP utilized the reduction process of H2O2 in a choline solution at −0.2 V. Experimental parameters affecting the sensitivity of sensors, such as pH, applied potential, and temperature were optimized. A performance comparison of two sensors showed that one based on ChO/HRP/CPME had a linear range from 1.0×10−6 to 8.0×10−5 M and the other based on ChO/CPME from 1.0×10−6 to 5.0×10−5 M. The detection limits for choline employing ChO/HRP/CPME and ChO/CPME were determined to be about 1.0×10−7 and 4.0×10−7 M, respectively. The response time of sensors was less than 5 s. Sensors showed good selectivity to interfering species. The long-term storage stability of the sensor based on ChO/HRP/CPME was longer than that based on ChO/CPME.  相似文献   

3.
This paper describes the combination of electrochemical immunosensor using gold nanoparticles (GNPs)/carbon nanotubes (CNTs) hybrids platform with horseradish peroxidase (HRP)-functionalized gold nanoparticle label for the sensitive detection of human IgG (HIgG) as a model protein. The GNPs/CNTs nanohybrids covered on the glass carbon electrode (GCE) constructed an effective antibody immobilization matrix and made the immobilized biomolecules hold high stability and bioactivity. Enhanced sensitivity was obtained by using bioconjugates featuring HRP labels and secondary antibodies (Ab2) linked to GNPs at high HRP/Ab2 molar ratio. The approach provided a linear response range between 0.125 and 80 ng/mL with a detection limit of 40 pg/mL. The immunosensor showed good precision, acceptable stability and reproducibility and could be used for the detection of HIgG in real samples, which provided a potential alternative tool for the detection of protein in clinical laboratory.  相似文献   

4.
There were discordant results regarding the effect of fetal sex on human chorionic gonadotropin (hCG) concentrations in maternal or fetal circulation and regarding whether the levels in umbilical arteries are equal to those in umbilical veins. Totally, 188 singleton pregnancies at 36 to 42 weeks of gestation without any obstetrical or medical complication were studied. The hCG levels were measured by radioimmunoassay specific for hCG using Sb3 antibody raised against beta-subunit of hCG. The maternal ages and parities between those who gave birth to a male or a female baby were not different statistically. The birth weights between male and female babies were also not different. The serum hCG levels had a wide range in maternal circulation (200-75,200 mIU/ml) and their distribution was positively skewed. The mean value (geometric mean, G.M.) in maternal circulation for those who carried a female fetus (11,500 mIU/ml) was significantly higher than that for those carrying a male fetus (6,470 mIU/ml) (P less than 0.001, Student's t-test). The hCG concentrations in umbilical veins of female fetuses were also higher than in those of male fetuses (G.M., 26.8 vs 19.5 mIU/ml, P less than 0.01, Student's t-test). Umbilical arterial hCG levels (G.M., 10.05 mIU/ml) were statistically not different from umbilical venous levels (G.M., 10.92 mIU/ml) (paired t-test).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

5.
A method has been developed for confirmation of the glycopeptide human chorionic gonadotropin (hCG) in urine. A solid-phase immunoaffinity trapping technique utilizing a monoclonal antibody recognizing both intact hCG and free hCG β-subunits was developed for the extraction of hCG from urine. Recovery of hCG from a urine matrix was essentially quantitative. The hCG was quantitatively eluted with 6 M guanidine hydrochloride, reductively alkylated with vinylpyridine, and subjected to tryptic digestion. The tryptic digest was analysed by HPLC-MS. Ions from three tryptic fragments were monitored with selected ion monitoring to provide specific detection of hCG. The signal observed for a concentration of 25 mIU/ml of hCG could be clearly distinguished from background with a signal-to-noise ratio of 12:1.  相似文献   

6.
《Analytical biochemistry》1985,146(2):393-401
A one-step two-site immunoradiometric assay for the measurement of free β subunit of human chorionic gonadotrophin (β-hCG) was developed using monoclonal antibodies. The immobilized antibody was specific for free β subunit and the radiolabeled antibody recognized both intact human chorionic gonadotrophin (hCG) and free β subunit. Although the level of hCG “cross-reaction” was low when studied using conventional techniques, the apparent β-hCG content of samples was found to be inversely proportional to the hCG level. From both experimental evidence and computer simulation studies this was found to be due to the binding of hCG to the limited amount of 125I-labeled antibody present. The term covert cross reactants has been introduced to describe substances which bind to only one of the antibodies in a two-site immunoassay. When establishing such an assay the effect of covert cross reactants on the response of an analyte should be investigated.  相似文献   

7.
A facile and sensitive electrochemical immunosensor for detection of human chorionic gonadotrophin (hCG) was designed by using functionalized mesoporous nanoparticles as bionanolabels. To construct high-performance electrochemical immunosensor, Au nanoparticles (AuNPs) dotted carbon nanotubes (MWCNTs)-graphene composite was immobilized on the working electrode, which can increase the surface area to capture a large amount of primary antibodies (Ab(1)) as well as improve the electronic transmission rate. The as-prepared bionanolabels. composed of mesoporous silica nanoparticles (MCM-41) coated with AuNPs through thionine linking, showed good adsorption of horseradish peroxidase-labeled secondary anti-hCG antibody. Interlayer thionine was not only a bridging agent between MCM-41 and AuNPs but also an excellent electron mediator. The approach provided a good linear response range from 0.005 to 500 mIU mL(-1) with a low detection limit of 0.0026 mIU mL(-1). The immunosensor showed good precision, acceptable stability and reproducibility. Satisfactory results were obtained for determination of hCG in human serum samples. The proposed method provides a new promising platform of clinical immunoassay for other biomolecules.  相似文献   

8.
9.
Immobilization of catalase into chemically crosslinked chitosan beads   总被引:8,自引:0,他引:8  
Bovine liver catalase was immobilized into chitosan beads prepared in crosslinking solution. Various characteristics of immobilized catalase such as the pH–activity curve, the temperature–activity curve, thermal stability, operational stability, and storage stability were evaluated. Among them the pH optimum and temperature optimum of free and immobilized catalase were found to be pH 7.0 and 35 °C. The Km value of immobilized catalase (77.5 mM) was higher than that of free enzyme (35 mM). Immobilization decreased in Vmax value from 32,000 to 122 μmol (min mg protein)−1. It was observed that operational, thermal and storage stabilities of the enzyme were increased with immobilization.  相似文献   

10.
Three-dimensionally (3D) ordered macroporous active carbon has been fabricated and used as electrode substrate for the direct electrochemistry of horse heart cytochrome c (Cyt c). The Cyt c immobilized on the surface of the ordered macroporous active carbon shows a pair of well-defined and nearly reversible redox waves at the formal potential of −0.033 V in pH 6.8 phosphate buffer solution. The interaction between Cyt c and the 3D macroporous active carbon makes the formal potential shift negatively compared to that of Cyt c in solution. Spectrophotometric and electrochemical methods have been used to investigate the interaction between Cyt c and the porous active carbon. The immobilized Cyt c maintains its biological activity, and shows a surface controlled electrode process with the electron-transfer rate constant (ks) of 17.6 s−1 and the charge-transfer coefficient (a) of 0.52, and displays the features of a peroxidase in the electrocatalytic reduction of hydrogen peroxide (H2O2). A potential application of the Cyt c-immobilized porous carbon electrode as a biosensor to monitor H2O2 has been investigated. The steady-state current response increases linearly with H2O2 concentration from 2.0 × 10−5 to 2.4 × 10−4 mol l−1. The detection limit (3σ) for determination of H2O2 has been found to be 1.46 × 10−5 mol l−1.  相似文献   

11.
We examined a 32-year-old Japanese man who was clinically diagnosed with gastric cancer, type 4, and histopathologically diagnosed with mucinous and poorly differentiated adenocarcinoma (mucinous > poorly) of the stomach. We successfully established and characterized a cell line (designated as IGSK-2) derived from the ascitic fluid of the patient with recurrent and cisplatin-resistant carcinoma. The IGSK-2 cells grew in multi-layered culture in culture dishes. The cells secreted 18 pg/mL somatostatin, 9.1 mIU/mL human chorionic gonadotrophin (hCG), 8000 U/mL carbohydrate antigen 19-9 and 410 ng/mL carcinoembryonic antigen over 4 days of culture. The population doubling time was approximately 83 h. The susceptibility test of anticancer drugs revealed that IGSK-2 cells were sensitive to Taxol, but were not sensitive to cisplatin, 5-fluorouracil and irinotecan. Immunohistochemical staining revealed that the IGSK-2 cells were positive against antihCG antibody and antiserotonin antibody, and negative against antisomatostatin antibody and antigastrin antibody.  相似文献   

12.
目的:制备人绒毛膜促性腺激素(beta-HCG)单克隆抗体,建立人beta-HCG双抗体夹心CLIA 检测方法。方法:用人beta-HCG 抗原 免疫小鼠,通过细胞融合、筛选后得到杂交瘤细胞株,然后将细胞株扩大培养并纯化上清液获得抗体,测定抗体亲和力、特异性及 表位,最后建立双抗体夹心CLIA方法。结果:获得4 株抗人茁-HCG的杂交瘤细胞株(beta-1-1、beta-2-1、beta-3-1、beta-4-1)。用beta-1-1 和 beta-2-1 建立的双抗体夹心法的检测范围为0.5 mIU/mL-800 mIU/mL,灵敏度0.23 mIU/mL,检测结果的相对偏差均在± 10 %内,回 收率在90 %以上。结论:本研究最终成功制备了抗人beta-HCG mAb,建立了定量检测人beta-HCG 的双抗体夹心CLIA 方法,为 beta-HCG 检测及疾病的诊断奠定基础。  相似文献   

13.
Silica gel bead coated with macroporous chitosan layer (CTS-SiO2) was prepared, and the metal immobilized affinity chromatographic (IMAC) adsorbents could be obtained by chelating Cu2+, Zn2+, Ni2+ ions, respectively on CTS-SiO2, and trypsin could be adsorbed on the IMAC adsorbent through metal–protein interaction forces. Batch adsorption experiments show that adsorption capacity for trypsin on these IMAC adsorbent variated with change of pH. The maximal adsorption reached when the solution was in near neutral pH in all three IMAC adsorbents. Adsorption isothermal curve indicated that maximal adsorption capacity could be found in the Cu2+-CTS-SiO2 with the value of 4980 ± 125 IU g−1 of the adsorbent, while the maximal adsorption capacity for trypsin on Zn2+ and Ni2+ loaded adsorbent was 3762 ± 68 IU g−1 and 2636 ± 53 IU g−1, respectively. Trypsin immobilized on the IMAC beads could not be desorbed by water, buffer and salt solution if the pH was kept in the range of 5–10, and could be easily desorbed from the IMAC beads by acidic solution and metal chelating species such as EDTA and imidazole. The effect of chelated metal ions species on CTS-SiO2 beads on the activity and stability of immobilized trypsin was also evaluated and discussed. Trypsin adsorbed on Zn-IMAC beads retained highest amount of activity, about 78% of total activity could be retained. Although the Cu-IMAC showed highest affinity for trypsin, only 25.4% of the calculated activity was found on the beads, while the activity recovery found on Ni-IMAC beads was about 37.1%. A remarkable difference on stability of trypsin immobilized on three kinds of metal ion chelated beads during storage period was also found. Activity of trypsin on Cu-IMAC decreased to 24% of its initial activity after 1-week storage at 4 °C, while about 80% activity was retained on both Ni-IMAC and Zn-IMAC beads. Trypsin immobilized on Zn-CTS-SiO2 could effectively digest BSA revealed by HPLC peptide mapping.  相似文献   

14.
This paper demonstrates that glucose determination in blood can be done directly (without sample pretreatment) using a reagentless reversible biosensor based on the intrinsic spectroscopic properties of peroxidase (HRP). The biosensor, prepared by HRP and glucose oxidase entrapment in a polyacrylamide gel matrix, works in continuous mode, presents a linear response range from 1.5 × 10−6 up to 5.5 × 10−5 M and can be used for at least 750 measurements; in the best conditions (0.1 M pH 6 phosphate buffer, HRP and GOx amounts in the polymersation mixture for the sensor film preparation 0.0165 and 0.0010 g, respectively) the minimum samples rate is 30 h−1. For glucose determination, blood is simply diluted in water (until haemolysis is completed) and fed into the sensor without a cleaning step between samples; the blood absorption is corrected in a simple way by working at a proper reference wavelength. The biosensor signals have been mathematically modeled in order to facilitate the design of sensors based on the same idea for other biochemical compounds.  相似文献   

15.
Bacillus macerans cyclodextrin glycosyltransferase (CGTase) fused with 10 lysine residues at its C-terminus (CGTK10ase) was immobilized onto a cation exchanger by ionic interaction and used to produce -cyclodextrin (CD) from soluble starch. Poly-lysine fused immobilization increased the Vm of the immobilized CGTase by 40% without a change in Km. The activation energies of thermal deactivation (Ea) were 41.4, 28.1, and 25.9 kcal mol−1, respectively, for soluble wild-type (WT) CGTase, soluble CGTK10ase, and immobilized CGTK10ase, suggesting destabilization of CGTase by poly-lysine fusion and immobilization onto a cation exchanger. Maximum -CD productivity of 539.4 g l−1 h−1 was obtained with 2% soluble starch solution which was constantly fed at a flow rate of 4.0 ml min−1 (D = 240 h−1) in a continuous operation mode of a packed-bed reactor. The operational half-life of the packed-bed enzyme reactor was estimated 12 days at 25 °C and pH 6.0.  相似文献   

16.
A simple and effective strategy for fabrication of hydrogen peroxide (H2O2) biosensor has been developed by entrapping horseradish peroxidase (HRP) in chitosan/silica sol–gel hybrid membranes (CSHMs) doped with potassium ferricyanide (K3Fe(CN)6) and gold nanoparticles (GNPs) on platinum electrode surface. The hybrid membranes are prepared by cross-linking chitosan (CS) with 3-aminopropyltriethoxysilane (APTES), while the presence of GNPs improved the conductivity of CSHMs, and the Fe(CN)63−/4− was used as a mediator to transfer electrons between the electrode and HRP due to its excellent electrochemistry activity. UV–Vis absorption spectroscopy was employed to characterize the different components in the CSHMs and their interaction. The parameters influencing the performance of the resulting biosensor were optimized and the characteristic of the resulting biosensor was characterized by cyclic voltammetry and chronoamperometry. Linear calibration for hydrogen peroxide was obtained in the range of 3.5 × 10− 6 to 1.4 × 10− 3 M under the optimized conditions with the detection limit (S/N = 3) of 8.0 × 10− 7 M. The apparent Michaelis–Menten constant of the enzyme electrode was 0.93 mM. The enzyme electrode retained about 78% of its response sensitivity after 30 days. The system was applied for the determination of the samples, and the results obtained were satisfactory.  相似文献   

17.
Hepatitis B surface antibody (HBsAb) was immobilized to the surface of a gold electrode modified with cysteamine and colloidal gold as matrices to detect hepatitis B surface antigen (HBsAg). Differential pulse voltammetry (DPV) method was used for the investigation of the specific interaction between the immobilized HBsAb and HBsAg in solution, which was followed as a change of peak current in DPV with time. With the modified gold electrode, the differences in affinity of HBsAb with HBsAg at the temperatures of 37 and 40 °C were easily distinguished and the kinetic rate constants (kass and kdiss) and kinetic affinity constant K were determined from the curves of current versus time. In addition, the thermodynamic constants, ΔG, ΔH and ΔS, of the interaction at 37 °C were calculated, which were −56.65, −64.54 and −25.45 kJ mol−1, respectively.  相似文献   

18.
An amperometric immunosensor was fabricated for the detection of osteoproteogerin (OPG) by covalently immobilizing a monoclonal OPG antibody (anti-OPG) onto the gold nanoparticles (AuNPs) deposited functionalized conducting polymer (5,2′:5′,2″-terthiophene-3′-carboxylic acid). AuNPs were electrochemically deposited onto the conducting polymer using cyclic voltammetry. The particle size of deposited AuNPs was controlled by varying the scan rate and was characterized by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The immobilization of anti-OPG was also confirmed using XPS. The principle of immunosensor was based on a competitive immunoassay between free-OPG and labeled-OPG for the active sites of anti-OPG. HRP was used as a label that electrochemically catalyzes the H2O2 reduction. The catalytic reduction was monitored amperometrically at −0.4 V vs. Ag/AgCl. The immunosensor showed a linear range between 2.5 and 25 pg/ml and the detection limit was determined to be 2 pg/ml. The proposed immunosensor was successfully applied for real human samples to detect OPG.  相似文献   

19.
Kinetics of tributyrin hydrolysis by lipase   总被引:1,自引:0,他引:1  
The kinetics for the tributyrin hydrolysis using lipase (Pseudomonas fluorscenes CCRC-17015) were investigated in the liquid–liquid and liquid–solid–liquid reaction systems in a batch reactor. The lipase was covalently immobilized onto the surface of porous polymethylacrylamide (PMAA) crosslinking with N,N-methylene biacrylamide with a spacer of ethylenediamine actived by glutaraldehyde. The conditions such as tributyrin concentration, temperature, agitation, and pH value, were evaluated to achieve the optimum reaction conditions for both free lipase and immobilized lipase. The kinetic parameters in the reaction system were also obtained for two reaction systems. The turnover numbers calculated for free lipase and immobilized lipase were 29 and 5.7 s−1, respectively. The parameters of k and km obtained using Lineweaver-Burk plot method were 26.2 mol/(mg min) and 1.35 mol/dm3 for free lipase, 5.2 mol/(mg min) and 0.2 mol/dm3 for immobilized lipase, respectively. The experimental results revealed good thermal stability, with greater stability at higher pH value for immobilized lipase in the liquid–solid–liquid reaction.  相似文献   

20.
A novel multi-channel 2 x 5 model of piezoelectric quartz micro-array immunosensor has been developed for quantitative detection of human chorionic gonadotropin (hCG) in serum or urine samples. Every crystal unit of the fabricated piezoelectric hCG micro-array immunosensor can oscillate independently without interfering each other. A 2 x 5 model of micro-array immunosensor as compared with a one-channel immunosensor can provide eight times higher detection speeds for hCG assay. The anti-hCG antibody is deposited on the gold electrode's surface of 10 MHz quartz AT-cut crystal by self-assembled technique using sulfosuccinimidyl 6-[3'-(2-pyridyldithio) propionamido] hexanoate (Sulfo-LC-SPDP), and serves as an antibody recognizing layer. The highly ordered self-assembled monolayers (SAM) ensure well-controlled surface structure and offer many advantages to the performance of the sensor. Compared with conventional antibody immobilization methods, the amount and the reaction activity of antibody monolayer coated by the SAM binding are bigger than those by the SPA method, and less non-specific binding caused by other analytes in sample is found. Under the optimized experimental conditions, the results showed that micro-array immunosensor quantitatively detected serum or urine hCG in the range of 2.5-500 mIU/ml with high precision (CV<5%); other hormones in human serum and urine did not interfere with the determination markedly. Serum and urine samples of 60 patients were detected by the micro-array immunosensor, and the results agreed well with those given by the commercial radioimmunoassay test kit, with correlation coefficient of 0.92. After regeneration with urea solution the coated immunosensor can be reused five times without appreciable loss of activity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号