共查询到20条相似文献,搜索用时 31 毫秒
1.
A photomicrobial sensor consisting of immobilized Chlorella vulgaris and an oxygen electrode has been developed for selective determination of phosphate. When 40 mM phosphate was added to the sensor system, the photocurrent increased to a maximum under light irradiation with a response time of 1 min. The current increased with increasing phosphate concentration in the range 8–70 mM. Selectivity of the sensor was satisfactory. Good agreement was obtained between the phosphate concentrations in lake water determined by the photomicrobial sensor and by conventional colorimetry (correlation coefficient 0.96). 相似文献
2.
Microbial sensor for selective determination of sulphide 总被引:2,自引:0,他引:2
H. Kurosawa T. Hirano K. Nakamura Y. Amano 《Applied microbiology and biotechnology》1994,41(5):556-559
A microbial sensor consisting of immobilized Thiobacillus thiooxidans, a gas-permeable membrane, and an O2 electrode was prepared for the determination of sulphide. When a sample solution containing sulphide was passed into the flow cell, the output of the microbial sensor decreased markedly with time until a steady state was reached. The total time required for an assay was 20–30 min by the steady-state method. In the pulse method, the total time required for an assay was about 5 min. A linear relationship was obtained between the sensor output and the concentration of sodium sulphide below 0.40 mm. The minimum detectable concentration of sodium sulphide was 0.02 mm. Selectivity of the sensor was satisfactory. The microbial sensor was applied to the determination of sulphide in spring water. A good agreement was obtained between the microbial sensor and the methylene blue method. The regression coefficient was 0.97 for five experiments. The activity of the microbial membrane was stable for more than 25 days. The response was reproducible with 2.5% of the relative standard deviation when a sample solution containing 0.2 mm sodium sulphide was employed. *** DIRECT SUPPORT *** AG903053 00005 相似文献
3.
Copper(II) complexes of di-, tri- and tetra peptides with previously published protonation constants were re-investigated using pH and copper ion selective electrode (ISE) potentiometry in conjunction with a modified version of HYPERQUAD computer program. The purpose was to demonstrate the suitability of the ISE approach for the determination of apparent stability constants for copper(II) complexes with ligands for which proton stability constants were not available. The interactions of Cu2+ with oligopeptides were also analysed using surface enhanced laser desorption/ionisation time-of-flight mass spectrometry (SELDI-ToF-MS). The results provide an insight into the metal complex species formed, their apparent stabilities under selected conditions and the effect of the relative positions of certain amino acids within the peptide sequence. 相似文献
4.
Sensitivity of calcium-selective electrodes heretofore has been limited to calcium concentrations above 10(-8) M in the absence of competing ions. We describe the use of calcium buffers to stabilize the free calcium in the reference electrode. Electrode calibration is linear to 10(-8) M and is curvilinear to 10(-11) M in the presence of 0.1 M ionic strength. Selectivity with respect to competing cations, magnesium, potassium, sodium, and hydrogen is preserved. Electrode response time is less than 2 s for small changes in calcium activity. Response range is linear over 9 log units of calcium activity. Potential-time stability is less than 10 mV/h at saturation currents. Although the silver-silver chloride terminals are photosensitive throughout the visible and near-ultraviolet regions, housing the reference and indifferent in opaque barrels avoids false photovoltaic response. 相似文献
5.
L-Lysine alpha-oxidase from Trichoderma viride Y244-2 is immobilized in a gelatin support and fixed on a pO(2) sensor. The enzyme electrode obtained is used in a continuous flow system in order to measure the concentration of L-lysine in a fermentor. The sample oxygen-content dependance of the signal is minimized because of the enzyme support properties. The enzyme electrode response is set for lysine concentration from 0.2mM to 4mM. The specificity of lysine is tested with other amino acids. The enzyme membrane for lysine electrode can be used 3000 times or stored six months with good stability. 相似文献
6.
Hock-Hin Yeoh 《Biotechnology Techniques》1993,7(10):761-764
Summary An enzyme electrode was constructed using cassava leaf linamarase covalently linked via polyethyleneimine to Hybond-N nylon. The nylon-enzyme electrode response was Nerstian for linamarin range of 0.1 to 20 mM. A steady state reading could be obtained within 4 to 6 mins. The nylon-enzyme discs could be reused. Compared to the previously reported enzyme electrode prepared by entrappment of linamarase in ENT-4000 prepolymer resins, the nylon-enzyme electrode gave faster response and could save analysis time by 60%. 相似文献
7.
A potentiometric penicillinase electrode is reported in which the base pH transducer is a thin-film anti-mony-antimony-oxide electrode deposited by vacuum evaporation. Several enzyme immobilization procedures have been examined and a crosslinked protein film found to be the most appropriate to this type of sensor. The use of an adjacent antimony-antimony-oxide track as a pseudoreference electrode was successfully demonstrated. The overall response was shown to be independent of the stirring rate above 100 rpm, but the kinetics of the response were found to depend markedly on the stirring rate. The intrinsic linear response range was 3 x 10(-4)Mto 7 x 10(-3)M penicillin G. Linearizing transforms that extend the useful range were examined. 相似文献
8.
A biosensor consisting of physically entrapped monomethyl sulfate (methyl sulfate) degrading bacterium, Hyphomicrobium MS 219, and a combined glass electrode has been developed for the determination of methyl sulfate. The response of the bacterial electrode is linear between 2.5 x 10(-2)M and 6.3 x 10(-1)M methyl sulfate with an effective response to concentrations as low as 10(-3)M and as high as 1M methyl sulfate. The probe has an average slope of 8 mV per concentration decade over the linear range. Response times vary from 5 min in the linear range to 30 min at the detection limit. The sensor has a lifetime of at least 1 week and shows high selectivity to methyl sulfate in the absence of other growth substrates. 相似文献
9.
10.
11.
A new enzyme electrode for the determination of alcohols was developed by immobilizing alcohol oxidase in polvinylferrocenium matrix coated on a Pt electrode surface. The amperometric response due to the electrooxidation of enzymatically generated H(2)O(2) was measured at a constant potential of +0.70 V versus SCE. The effects of substrate, buffer and enzyme concentrations, pH and temperature on the response of the electrode were investigated. The optimum pH was found to be pH 8.0 at 30 degrees C. The steady-state current of this enzyme electrode was reproducible within +/-5.0% of the relative error. The sensitivity of the enzyme electrode decreased in the following order: methanol>ethanol>n-butanol>benzyl alcohol. The linear response was observed up to 3.7 mM for methanol, 3.0 mM for ethanol, 6.2 mM for n-butanol, and 5.2 mM for benzyl alcohol. The apparent Michaelis-Menten constant (K(Mapp)) value and the activation energy, E(a), of this immobilized enzyme system were found to be 5.78 mM and 38.07 kJ/mol for methanol, respectively. 相似文献
12.
Summary Laccase (p-diphenol, O2 oxido-reductase, E.C. 1.10.3.2) from Botrytis cinerea was immobilized in a gelatin support on an O2 sensing electrode. The enzyme was copolymerized with the inert protein using glutaraldehyde (1.25 % w/w) on the hydrophobic selective gas membrane of a pO2 sensor and this was covered with a Nuclepore polycarbonate microporous film (0.03 m). The enzyme electrode was used in a continuous-flow system to measure the concentration of a wide range of phenolic substrates. The measuring time of each sample was about 1.5 min including response and rinsing times. The electrode response was set for hydroquinone up to 0.8 mM with high reproducibility and less than 5 % error.The electrode response for hydroquinone concentration of 0.25 mM was stable with repeated use for at least 800 assays without significant loss of activity. 相似文献
13.
A simple selective method for determination of ascorbic acid using polymerized direct blue 71 (DB71) is described. Anodic polymerization of the azo dye DB71 on glassy carbon (GC) electrode in 0.1M H(2)SO(4) acidic medium was found to yield thin and stable polymeric films. The poly(DB71) films were electroactive in wide pH range (1-13). A pair of symmetrical redox peaks at a formal redox potential, E('0)=-0.02V vs. Ag/AgCl (pH 7.0) was observed with a Nernstian slope -0.058V, is attributed to a 1:1 proton+electron involving polymer redox reactions at the modified electrode. Scanning electron microscope (SEM), atomic force microscope (AFM) and electrochemical impedance spectroscopy (EIS) measurements were used for surface studies of polymer modified electrode. Poly(DB71) modified GC electrode showed excellent electrocatalytic activity towards ascorbic acid in neutral buffer solution. Using amperometric method, linear range (1x10(-6)-2x10(-3)M), dynamic range (1x10(-6)-0.01M) and detection limit (1x10(-6)M, S/N=3) were estimated for measurement of ascorbic acid in pH 7.0 buffer solution. Major interferences such as dopamine and uric acid are tested at this modified electrode and found that selective detection of ascorbic acid can be achieved. This new method successfully applied for determination of ascorbic acid in commercial tablets with satisfactory results. 相似文献
14.
Since a stable alcohol oxidase with a high specific activity is not commercially available, we propose to produce and purify this enzyme from a strain of the yeast Hansenula polymorpha. This alcohol oxidase was immobilized into a gelatin matrix and its activity was estimated by a pO(2) sensor. The enzyme electrode obtained was then used in a continuous flow system to measure methanol or ethanol concentrations. The sample oxygen content dependence of the signal was minimized by the support properties. Measuring time for each sample were less than two minutes including response data treatment and rinsing step. The enzyme electrode response was set for ethanol from 0.5mM to 15mM and for methanol from 10mM to 300mM. On repeated use, the electrode signal for 10mM of ethanol was stable for at least 500 assays. Analysis have been performed in different beverages such as wine and beer, and the results compared to those obtained with classical methods of analysis. 相似文献
15.
Immobilization of glucose oxidase in electropolymerized polypyrrole film on the surface of a platinum wire electrode, provides a convenient sensor for flow-injection glucose determination. An upper limit of linear response for 100 microliters injected sample volume was estimated as 20 mM, whereas a 500 microliters injected sample volume gave an estimated detection limit of 0.5 mM. A simple electrode preparation procedure allows quick electrode renewal before each series of measurements. 相似文献
16.
This paper describes an amperometric enzyme electrode for the rapid determination of theophylline in serum. The method is based on the catalysed oxidation of theophylline by the haem-containing enzyme theophylline oxidase. Results are presented for two approaches. First, ferrocene monocarboxylic acid was used as a mediator. The second-order rate constant was 1.1 x 10(3) 1 mol-1 s-1. Secondly, the organic conducting salt NMP.TCNQ was used to construct enzyme electrodes. These electrodes were employed for the rapid (60 s) measurement of theophylline in serum at a working potential of +100 mV versus Ag/AgCl. Linear calibration curves were obtained over the clinically relevant range (y = 0.13x + 0.22, n = 8). Caffeine, theobromine and 3-methylxanthine at levels up to 100 mg l-1 do not interfere and 1-methylxanthine shows cross-reactivity at concentrations greater than 50 mg l-1. 相似文献
17.
Highly sensitive and selective electrochemiluminescence determination of cholesterol utilizing a functional electrode with a core–shell nanostructure 下载免费PDF全文
A highly sensitive and selective method for the determination of cholesterol is required to evaluate trace amounts of cholesterol in test samples. In this work, selected gold nanoparticles (AuNPs) and 5‐amino‐2‐mercapto‐1,3,4‐thiadiazole (AMT) were used and a thin film of three‐dimensional gold–AMT core–shell nanoparticles (p‐AMT–AuNPs) was prepared using an electrochemical method. Cholesterol oxidase was then bonded to the film surface to give a functional electrode. Based on catalysis by the electrode functionalized for cholesterol and a luminol–H2O2 electrochemiluminescence (ECL) system, a highly sensitive and selective ECL method was developed for the determination of cholesterol. Under optimized conditions, ECL intensity showed a good linear relationship with cholesterol over the concentration range 0.05–11.0 µg/ml, with a correlation coefficient of 0.999 and a limit of detection of 0.02 µg/ml. The proposed method was used to determine cholesterol in dairy products with a relative standard deviation of < 1.8% and recovery rates of 98.1–104%. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
18.
Summary A method based on absorption of Fe(III) at 300 nm was developed and then applied to bacterial leaching of iron-containing metal sulphides. 相似文献
19.
Real-time determination of kinetics of adsorption of lead(II) onto palm shell-based activated carbon using ion selective electrode 总被引:2,自引:0,他引:2
In this study, the kinetics of adsorption of Pb(II) from aqueous solution onto palm shell-based activated carbon (PSAC) were investigated by employing ion selective electrode (ISE) for real-time Pb(II) and pH monitoring. Usage of ISE was very appropriate for real-time adsorption kinetics data collection as it facilitated recording of adsorption data at very specific and short time intervals as well as provided consistent kinetics data. Parameters studied were initial Pb(II) concentration and agitation speed. It was found that increases in initial Pb(II) concentration and agitation speed resulted in higher initial rate of adsorption. Pseudo first-order, pseudo second-order, Elovich, intraparticle diffusion and liquid film diffusion models were used to fit the adsorption kinetics data. It was suggested that chemisorption was the rate-controlling step for adsorption of Pb(II) onto PSAC since the adsorption kinetics data fitted both the pseudo second-order and Elovich models well. 相似文献
20.
G Baum 《Analytical biochemistry》1971,39(1):65-72