首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The recent discovery that metal‐free polyterthiophene (PTTh) prepared by iodine‐vapor‐assisted polymerization (IVP) can catalyze the hydrogen evolution reaction (HER) when illuminated, and this light‐enhanced electrolysis expresses a non‐Nernstian relation with pH, provides the foundation for further improvement of the photovoltage of the reaction by engineering the band structure of the light‐absorbing polymer. Deviating from an all‐thiophene backbone, using poly(1,4‐di(2‐thienyl))benzene (PDTB) lowers the highest occupied molecular orbital level by ≈0.3 eV compared with polythiophene, and PDTB simultaneously maintains the photoelectrocatalytic properties without an all‐thiophene backbone, resulting in very high conversion rate of 600 mmol(H2) h?1 g?1 at 0 V versus the reversible hydrogen electrode (RHE) at pH 11. PDTB shows the same non‐Nernstian behavior as PTTh with increasing onset potential (versus RHE) at higher pH, and the open circuit potential on PDTB under visible light reaches 1.4 V versus RHE at pH 12. The PDTB photocathode thus produces a photovoltage above the theoretical potential for the complete water‐splitting (1.229 V) and is indeed able to produce hydrogen in a one‐photon‐per‐electron light‐driven water splitting setup with MnOx as the anode at a rate of 6.4 mmol h?1 gPDTB?1.  相似文献   

2.
1,4‐Dithiothreitol (DTT) has wide applications in cell biology and biochemistry. Development of effective methods for monitoring DTT in biological systems is important for the safe handling and study of toxicity to humans. Herein, we describe a two‐photon fluorescence probe (Rh‐DTT) to detect DTT in living systems for the first time. Rh‐DTT showed high selectivity and sensitivity to DTT. Rh‐DTT can be successfully used for the two‐photon imaging of DTT in living cells, and also can detect DTT in living tissues and mice.  相似文献   

3.
A terbium‐sensitized spectrofluorimetric method has been developed for determination of catecholamines such as norepinephrine (NE), epinephrine (EP) and dopamine (DA), using sodium dodecyl benzene sulphonate (SDBS). Fluorescence sensitization of terbium ions (Tb3+) by complexation with catecholamines in the presence of SDBS was observed. The fluorescence intensities of the Tb3+–catecholamine complexes were highly enhanced by introducing SDBS with an emission maximum at 545 nm after excitation at 290 nm. The conditions for the complex formation of Tb3+–catecholamine were investigated systematically and optimized to determine catecholamines in a serum sample. Under the optimum conditions, the fluorescence intensities of the Tb3+–catecholamine complexes were increased linearly with the concentration of NE, EP and DA over the ranges 2.5 × 10–10–1.0 × 10–8, 2.5 × 10–10–1.0 × 10–8 and 2.5 × 10–9–1.0 × 10–7 g/mL with correlation coefficients of 0.999, 0.999 and 0.9996, respectively. The limits of detection (3δ) of NE, EP and DA were found to be 4.6 × 10–11, 7.8 × 10–11 and 8.38 × 10–10 g/mL, respectively. Precision of the method was tested at the concentration level of 1.2 × 10?7 g/mL for five replicate measurements of NE, EP and DA, giving relative standard deviations (RSDs) of 1.41%, 1.23% and 1.89%, respectively. The interaction mechanism of the Tb3+–catecholamine complexes system was investigated and presented with ultraviolet absorption spectra. The proposed method has been applied for the quantitative determination of NE, EP and DA in a spiked serum sample and a pharmaceutical preparation sample. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
A novel ligand, 1‐(naphthalen‐2‐yl)‐2‐(phenylsulthio)ethanone was synthesized using a new method and its two europium (Eu) (III) complexes were synthesized. The compounds were characterized by elemental analysis, coordination titration analysis, molar conductivity, infrared, thermo gravimetric analyzer‐differential scanning calorimetry (TGA‐DSC), 1H NMR and UV spectra. The composition was suggested as EuL5 · (ClO4)3 · 2H2O and EuL4 · phen(ClO4)3 · 2H2O (L = C10H7COCH2SOC6H5). The fluorescence spectra showed that the Eu(III) displayed strong characteristic metal‐centered fluorescence in the solid state. The ternary rare earth complex showed stronger fluorescence intensity than the binary rare earth complex in such material. The strongest characteristic fluorescence emission intensity of the ternary system was 1.49 times as strong as that of the binary system. The phosphorescence spectra were also discussed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
6.
Chemiluminescence (CL) detection for the determination of estrogen benzoate, using the reaction of tris(1,10–phenanthroline)ruthenium(II)–Na2SO3–permanganate, is described. This method is based on the CL reaction of estrogen benzoate (EB) with acidic potassium permanganate and tris(1,10–phenanthroline)ruthenium(II). The CL intensity is greatly enhanced when Na2SO3 is added. After optimization of the different experimental parameters, a calibration graph for estrogen benzoate is linear in the range 0.05–10 µg/mL. The 3 s limit of detection is 0.024 µg/mL and the relative standard deviation was 1.3% for 1.0 µg/mL estrogen benzoate (n = 11). This proposed method was successfully applied to commercial injection samples and emulsion cosmetics. The mechanism of CL reaction was also studied. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
8.
Two new homo- and hetero-dinuclear complexes, [Cu2L(im)](ClO4)34H2O (1) and [CuZnL(im)](ClO4)34H2O (2) (where Im=1H-1midazole and L = 3, 6, 9, 16, 19, 22-hexaaza-6, 19-bis(1H-imidazol-4-ylmethyl)tricycle[22, 2, 2, 211,14]triaconta-1, 11, 13, 24, 27, 29-hexaene) were synthesized and characterized as model compounds for the active site of copper(II)–zinc(II) superoxide dismutase (Cu2Zn2–SOD). X-ray crystal structure analysis revealed that the metal centers in both complexes exhibit distorted trigonal-bipyramid coordination geometry and the CuCu and CuZn distances are both 6.02 Å. Magnetic and ESR spectral measurements of 1 showed antiferromagnetic exchange interactions between the imidazolate-bridged Cu(II) ions. The ESR spectrum of 2 displays typical signals of mononuclear Cu(II) complex, demonstrating the formation of heterodinuclear complex 2 rather than a mixture of homodinuclear Cu(II)/Zn(II) complexes. pH-dependent ESR and UV–visible spectral measurements manifest that the imidazolate exists as a bridging ligand from pH 6 to 11 for both complexes. The IC50 values of 1.96 and 1.57 μM [per Cu(II) ion] for 1 and 2 suggest that they are good models for the Cu2Zn2–SOD.  相似文献   

9.
A simple, rapid chemiluminescence (CL) method was described for the determination of piroxicam, a commonly used analgesic agent drug. A strong CL signal was detected when cerium(IV) sulphate was injected into tris‐(4,7‐diphenyl‐1,10‐phenanthrolinedisulphonic acid) ruthenium(II) (RuBPS)–piroxicam solution. The CL signal was proportional to the concentration of piroxicam in the range 2.8 × 10–8–1.2 × 10–5 mol/L. The detection limit was 2 × 10–8 mol/L and the relative standard deviation (RSD) was 3.7% (c = 7.0 × 10–7 mol/L piroxicam; n = 11). The proposed method was applied to the determination of piroxicam in pharmaceutical preparations in capsules, spiked serum and urine samples with satisfactory results. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

10.
11.
A sensitive and selective spectrofluorimetric method has been developed for the rapid determination of aluminium. This method is based on the complex formation between aluminium and 2‐hydroxy‐1‐naphthylidene‐(8‐aminoquinoline) (HNAQ). The optimum conditions for the complex formation were a metal‐to‐ligand (M : L) stoichiometric ratio of 1:1, a pH of 5.5 and a 0.20 m acetate buffer. The fluorescence of the complex was monitored at an emission wavelength of 502 nm with excitation at 438 nm. Under these conditions, linear calibration curves were obtained in the ranges 0.05–1 and 1–5 ppm. The detection limit was 3.4 ppb for the former and 13.5 ppb for the latter. The maximum relative standard deviation of the method for an aluminium standard of 200 ppb was 1.5% (n = 5). This method was successfully applied for the determination of aluminium in drinking water, pharmaceutical antacid tablets and suspension samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
Fang Zhao  Qi Fan  Huan Cai 《Luminescence》2014,29(3):219-224
A novel, rapid and sensitive chemiluminescence (CL) method combined with flow‐injection (FI) has been established for the estimation of olanzapine. This method is based on the CL signal generated between N‐chlorosuccinimide and olanzapine in an alkaline medium in the presence of calcein and Zn(II). Under optimum conditions, the CL signal was proportional to the olanzapine concentration ranging from 1.0 × 10‐10 to 3.0 × 10‐7 g/mL. The detection limit is 8.9 × 10‐11 g/mL olanzapine (3σ) and the relative standard deviation for 3.0 × 10‐9 g/mL of olanzapine is 1.9% (n = 11). The current CL method was applied to determine olanzapine in pharmaceutical formulations and biological fluids with satisfactory results. The possible CL reaction mechanism is discussed briefly. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
The fluorescence of the prulifloxacin (PUFX)–Al(III) system was investigated . Experiments indicated that the fluorescence intensity of prulifloxacin could be greatly enhanced by Al(III) and sensitized by sodium dodecylbenzene sulphonate (SDBS). Accordingly, a sensitive spectrofluorimetric method for the determination of prulifloxacin was established. While excited at 275 nm, the enhanced fluorescence intensity at 412 nm of the system (ΔF) showed a good linear relationship with the concentration of prulifloxacin within the range 4.0 × 10–8–3.0 × 10–6 mol/L. The regression equation was ΔF = 9.83 + 10.8 × 107c (mol/L); the correlation coefficient and detection limit (3σ/k) were 0.99901 and 2.0 × 10–8 mol/L, respectively. The proposed method has been successfully applied to determine prulifloxacin in real pharmaceutical samples. The luminescence mechanism of the system is also discussed in detail. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

14.
To develop conducting organic polymers (COPs) as luminescent sensors for determination of toxic heavy metals, a new benzene sulfonic acid‐doped polypyrrole (PPy‐BSA) thin film was electrochemically prepared by cyclic voltammetry (CV) on flexible indium tin oxide (ITO) electrode in aqueous solution. PPy‐BSA film was characterized by FTIR spectrometry, X‐ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). The optical properties of PPy‐BSA were investigated by ultraviolet (UV)‐visible absorption and fluorescence spectrometry in dimethylsulfoxide (DMSO) diluted solutions. PPy‐BSA fluorescence spectra were strongly quenched upon increasing copper(II) ion (Cu2+) and lead(II) ion (Pb2+) concentrations in aqueous medium, and linear Stern–Volmer relationships were obtained, which indicated the existence of a main dynamic fluorescence quenching mechanism. BSA‐PPy sensor showed a high sensitivity for detection of both metallic ions, Cu2+ and Pb2+, with very low limit of detection values of 3.1 and 18.0 nM, respectively. The proposed quenching‐fluorimetric sensor might be applied to the determination of traces of toxic heavy metallic ions in water samples.  相似文献   

15.
A new sensitive and instantaneous spectrofluorimetric method for efficient determination of lomefloxacin (LMX) in its pure, dosage form and human plasma was designed. The developed method depends on formation of a metal-chelation compound of LMX as a ligand with zinc(II) in a buffer of acetate (pH 5.5). The following parameters; type of metal, concentration of metal, pH, type of buffer and diluting solvent were optimized. After carefully investigation; 0.2 mM zinc, 2.0 ml acetate buffer (pH 5.5) and water as diluting solvent were set as optimum reaction conditions. Under these conditions, a large increase in the intensity of the fluorescence of LMX was attained at 450 after excitation at 284 nm. The limits of detection and quantification were 5.8 and 1.9 ng ml−1, respectively, with linearity range of 10.0 to 500.0 ng ml−1. The binding mode of LMX and zinc(II) ion (Zn2+) was found to be 2:1, respectively, and confirmed by Job's plot method. Furthermore, it extended to the analysis of LMX in the spiked plasma of humans with percentage recovery (98.70 ± 0.97 to 100.30 ± 1.69%, n = 3).  相似文献   

16.
A flow injection method with chemiluminescence detection is reported for the determination of vitamin A. The method is based on the enhancement effect of vitamin A on chemiluminescence of tris(2,2′‐bipyridyl)Ru(II)–Ce(IV) in acidic medium. The proposed procedure is used to quantitate vitamin A in the range 1.0–100 × 10?6 mol/L with a correlation coefficient of 0.9991 (n = 9) and relative standard deviation in the range 1.2–2.3% (n = 4). The limit of detection (3 × blank) was 8.0 × 10?8 mol/L with a sample throughput of 100/h. The effect of common excipients used in pharmaceutical formulations and some clinically important compounds was also studied. The method was applied to determine vitamin A in pharmaceutical formulations and the results obtained were in reasonable agreement with the amount quoted. The results were compared using spectrophotometric method and no significant difference was found between the results of the two methods at 95% confidence limit. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A sequential injection (SI) method was developed for the determination of chlorpheniramine (CPA), based on the reaction of this drug with tris(1,10‐phenanthroline)–ruthenium(II) [Ru(phen)32+] and peroxydisulphate (S2O82–) in the presence of light. The instrumental set‐up utilized a syringe pump and a multiposition valve to aspirate the reagents [Ru(phen)32+ and S2O82–] and a peristaltic pump to propel the sample. The experimental conditions affecting the chemiluminescence reaction were systematically optimized, using the univariate approach. Under the optimum conditions linear calibration curves of 0.1–10 µg/ml were obtained. The detection limit was 0.04 µg/ml and the relative standard deviation (RSD) was always < 5%. The procedure was applied to the analysis of CPA in pharmaceutical products and was found to be free from interferences from concomitants usually present in these preparations. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
Lipase from Pseudomonas cepacia was made soluble in 1,4‐dioxane by lyophilization of the enzyme from aqueous solutions containing methoxypoly(ethylene glycol) (PEG). The solubility of the enzyme–PEG complex depended both on protein concentration and PEG protein ratio. Intrinsic protein fluorescence and far‐ and near‐UV circular dichroism revealed that not only did the enzyme not unfold in the organic solvent, but rather became more compact. This was seen by the slight quenching of fluorescence intensity and by the enhancement of the near‐UV circular dichroism negative signals, which are indicative of stronger interactions of tryptophanyl and/or tyrosyl residues among themselves or with other parts of the enzyme molecule. The specific activity of the lipase–PEG complex in the organic solvent was at least 2 orders of magnitude higher than that of the enzyme powder. This can be attributed both to the maintenance of native conformation and to enzyme dissolution in the reaction medium which should minimize possible limitations to enzyme–substrate interactions. © 1999 John Wiley & Sons, Inc., Biotechnol Bioeng 64: 624–629, 1999.  相似文献   

19.
A sensitive and simple spectrofluorimetric method has been developed and validated for the determination of the anti‐epileptic drug carbamazepine (CBZ) in its dosage forms. The method was based on a nucleophilic substitution reaction of CBZ with 4‐chloro‐7‐nitrobenzo‐2‐ oxa‐1,3‐diazole (NBD‐Cl) in borate buffer (pH 9) to form a highly fluorescent derivative that was measured at 530 nm after excitation at 460 nm. Factors affecting the formation of the reaction product were studied and optimized, and the reaction mechanism was postulated. The fluorescence–concentration plot is rectilinear over the range of 0.6–8 µg/mL with limit of detection of 0.06 µg/mL and limit of quantitation of 0.19 µg/mL. The method was applied to the analysis of commercial tablets and the results were in good agreement with those obtained using the reference method. Validation of the analytical procedures was evaluated according to ICH guidelines. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号