首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper reviews publicaions that combine the technique of flow injection (FI) with chemiluminescence (CL) and bioluminescence (BL) detection, from the earliest papers in 1979/80 to mid-1992, and refers exclusively to reactions occurring in solution. Airsegmented systems and liquid chromatography with CL detection are not considered unless FI has been used to pre-optimize the system. The applications have been categorized in terms of the type of CL reaction; there are separate entries for luminol, peroxyoxalate, other CL reactions and BL reactions. Each of the four sections includes a table of applications that lists the analyte, the nature of the reaction, the sample matrix and the limit of detection.  相似文献   

2.
Disposable microfluidic devices: fabrication, function, and application   总被引:5,自引:0,他引:5  
Fiorini GS  Chiu DT 《BioTechniques》2005,38(3):429-446
This review article describes recent developments in microfluidics, with special emphasis on disposable plastic devices. Included is an overview of the common methods used in the fabrication of polymer microfluidic systems, including replica and injection molding, embossing, and laser ablation. Also described are the different methods by which on-chip operations--such as the pumping and valving of fluid flow, the mixing of different reagents, and the separation and detection of different chemical species--have been implemented in a microfluidic format. Finally, a few select biotechnological applications of microfluidics are presented to illustrate both the utility of this technology and its potential for development in the future.  相似文献   

3.
This paper reviews the literature on analytical applications of quantitative liquid phase chemiluminescence (CL) from 1991 to mid-1995. Other relevant reviews in this general area are also cited to provide an historical perspective. The focus is on the two major analytical techniques used in conjunction with flow-through CL detection, namely flow injection (FI) and liquid chromatography (LC). Entries have been tabulated under these two headings and are categorized in terms of the analyte, CL reaction, sample matrix and limits of detection.  相似文献   

4.
This mini‐review describes the recent developments in quantum dots‐based nanoprobes in liquid‐phase chemiluminescence (CL) analysis. In the referenced reports, multiple quantum dots (QDs) were adopted as final emission species either after direct oxidation reactions (direct CL) or after chemiluminescence resonance energy transfer (indirect CL). This review does not include papers in which QDs have been used as enhancers, catalysts, carriers or quenchers in chemiluminescence systems. A brief overview on the CL mechanisms of various QDs‐based nanoprobes and their analytical applications over the last decade is given, followed by comments on the future challenges and prospects in this field.  相似文献   

5.
A simple and rapid capillary electrophoresis (CE) with an acidic potassium permanganate chemiluminescence (CL) detection method was developed to determine three alkaloids (curine, sinomenine and magnoflorine) simultaneously. A laboratory‐built CE–CL detection interface was used. The field‐amplified sample stacking technique was applied to the online concentration of alkaloids. Experimental conditions for CE separation and CL detection were investigated in detail to acquire optimum conditions. Under optimal conditions, the three alkaloids were baseline separated within 6 min, and the detection limits (S/N = 3) ranged from 0.03 µg/mL to 0.49 µg/mL. This method was successfully applied to determine the above three alkaloids in Sinomenium acutum, and the result of the determination of sinomenine was in good agreement with those given by high‐performance liquid chromatography and CE methods. In addition, a possible CL reaction mechanism of sinomenine–KMnO4–H2SO4 was proposed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
Organ culture systems are used to elucidate the mechanisms of pattern formation in developmental biology. Various organ culture techniques have been used, but the lack of microcirculation in such cultures impedes the long‐term maintenance of larger tissues. Recent advances in microfluidic devices now enable us to utilize self‐organized perfusable capillary networks in organ cultures. In this review, we will overview past approaches to organ culture and current technical advances in microfluidic devices, and discuss possible applications of microfluidics towards the study of developmental biology.  相似文献   

7.
A novel automated precolumn derivatization followed by separation using liquid chromatography for the determination of pseudoephedrine (PSE) by a microfluidic chemiluminescence detector has been developed. An on‐line derivatization procedure was utilized by converting PSE into a highly light emitting species in a Ru(bipy)32+‐peroxydisulphate chemiluminescence (CL) system by derivatizing it with a 1.0 M formaldehyde solution. The derivatized analyte was directly injected into a microbore high‐performance liquid chromatography (HPLC) system coupled to an on‐chip chemiluminescence detector. The newly developed highly selective, sensitive and fast HPLC‐CL method was validated and successfully applied for the analysis of PSE in pharmaceutical formulations and a human urine sample. The selectivity of the method is not only due to the HPLC separation but is also due to the highly selective detection principle of the Ru(bipy)32+‐peroxydisulphate CL system used. There was no interference observed from the common preservatives and excipients used in pharmaceutical preparations, which did not show any significant CL signal. The retention time of PSE was less than 3 min, and the detection limits and quantification limits were found to be 5.7 and 26.0 µg L–1, respectively. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
CdS nanoparticles (CdS NPs) of different sizes were synthesized by the citrate reduction method. It was found that CdS NPs could enhance the chemiluminescence (CL) of the luminol‐potassium ferricyanide system and baicalin could inhibit CdS NPs‐enhanced luminol‐potassium ferricyanide CL signals in alkaline solution. Based on this inhibition, a flow‐injection CL method was established for determination of baicalin in pharmaceutical preparations and human urine samples. Under optimized conditions, the linear range for determination of baicalin was 5.0 x 10?6 to 1.0 x 10?3 g/L. The detection limit at a signal‐to‐noise ratio of 3 was 1.7 x 10 ?6 g/L. CL spectra, UV‐visible spectra and transmission electron microscopy (TEM) were used to investigate the CL mechanism. The method described is simple, selective and obviates the need of extensive sample pretreatment. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
A new simple, accurate and sensitive sequential injection analysis chemiluminescence (CL) detection method for the determination of cefditoren pivoxil (CTP) has been developed. The developed method was based on the enhancement effect of silver nanoparticles on the CL signal arising from a luminol–potassium ferricyanide reaction in the presence of CTP. The optimum conditions relevant to the effect of luminol, potassium ferricyanide and silver nanoparticle concentrations were investigated. The proposed method showed linear relationships between relative CL intensity and the investigated drug concentration at the range 0.001–5000 ng/mL, (r = 0.9998, n = 12) with a detection limit of 0.5 pg/mL and quantification limit of 0.001 ng/mL. The relative standard deviation was 1.6%. The proposed method was employed for the determination of CTP in bulk drug, in its pharmaceutical dosage forms and biological fluids such as human serum and urine. The interference of some common additive compounds such as glucose, lactose, starch, talc and magnesium stearate was investigated. In addition, the interference of some related cephalosporins was tested. No interference was recorded. The obtained sequential injection analysis‐CL results were statistically compared with those from a reported method and did not show any significant differences. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
A simple and ultrasensitive flow injection chemiluminescence competitive immunoassay based on gold nanoparticle‐loaded enzyme for the detection of chloramphenicol (CAP) residues in shrimp and honey has been developed. Due to their good biocompatibility and large specific surface area, carboxylic resin beads can be used as solid phase carriers to immobilize more coating antigens (Ag). In addition, gold nanoparticles could provide an effective matrix for loading more CAP antibody and horseradish peroxidase, which would effectively catalyze the system of luminol–p‐iodophenol (PIP)–H2O2. A competitive immunoassay strategy was used for detection of CAP, in which CAP in the sample would compete with the coating Ag for the limited antibodies, leading to a chemiluminescence (CL) signal decrease with increase in CAP concentration. A wide linear range 0.001–10 ng ml?1 (R2 = 0.9961) was obtained under optimized conditions, and the detection limit (3σ) was calculated to be 0.33 pg ml?1. This method was also been successfully applied to determine CAP in shrimp and honey samples. The immunosensor proposed in this study not only has the advantages of high sensitivity, wider linear range, and satisfactory stability, but also expands the application of flow injection CL immunoassay in antibiotic detection.  相似文献   

11.
A review of chromatographic methods for the determination of 2,3-benzodiazepines (2,3-BZs) is presented. The determinations are performed to investigate the presence of potential impurities in drug substances and to study their pharmacokinetic profile in biological samples, either in animals or in humans. Several methods dealt with a pretreatment of samples, i.e., liquid–liquid extraction by using a variety of solvents, solid-phase extraction, direct injection of specimens into the chromatographic apparatus. Different chromatographic techniques have been used. High-performance liquid chromatography allows optimal sensitivity and specificity by using ultraviolet or diode array detection methods. Gas chromatography-mass spectrometry and gas chromatography with nitrogen-phosphorous or electron-capture detectors have been also reported. Suitable methods for the separation of enantiomers of 2,3-BZs have been described. Thin-layer chromatography has been shown to be capable to isolate analytes from biological samples as urine or faeces. The reported chromatographic techniques are currently applied to define the metabolic pathways of 2,3-BZs in experimental and clinical studies.  相似文献   

12.
It was found that flavonoids could remarkably inhibit the chemiluminescence (CL) intensity of an off‐line gold nanoparticle (AuNP)‐catalyzed luminol–H2O2 CL system. By contrast, flavonoids enhanced the CL intensity of an on‐line AuNP‐catalyzed luminol–H2O2 CL system. In the off‐line system, the AuNPs were prepared beforehand, whereas in the on‐line system, AuNPs were produced by on‐line mixing of luminol prepared in a buffer solution of NaHCO3 ? Na2CO3 and HAuCl4 with no need for the preliminary preparation of AuNPs. The on‐line system had prominent advantages over the off‐line system, namely a lowering of the background noise and improvements in the stability of the CL system. The results show that differences in the signal suppression effect of flavonoids on the off‐line AuNP‐catalyzed CL system are influenced by the combined action of a free radical scavenging effect and occupy‐sites function; the latter was proved to be predominant using controlled experiments. Enhancement of the on‐line system was ascribed to the presence of flavonoids promoting the on‐line formation of AuNPs, which better catalyzed the luminol–H2O2 CL reaction, and the enhancement activity of the six flavonoids increased with the increase in reducibility. This work broadens the scope of practical applications of an AuNP‐catalyzed CL system.  相似文献   

13.
A highly sensitive, rapid and economical method for the determination of amlodipine (AM) in biological fluids was developed using a peroxyoxalate chemiluminescence (CL) system in a lab‐on‐a‐chip device. Peroxyoxalate‐CL is an indirect type of CL that allows the detection of native fluorophores or compounds derivatized with fluorescent labels. Here, fluorescamine was reacted with AM, and the derivatization product was used in a bis‐(2,4,6‐trichlorophenyl)oxalate‐CL system. Fluorescamine reacts selectively with aliphatic primary amine at neutral or basic pH. As most of the calcium channel blocker and many cardiovascular drugs do not contain primary amine, the developed method is highly selective. The parameters that influenced the CL signal intensity were studied carefully. These included the chip geometry, pH, concentration of reagents used and flow rates. Moreover, we confirmed our previous observation about the effects of imidazole, which is commonly used in the bis‐(2,4,6‐trichlorophenyl)oxalate‐CL system as a catalyst, and found that the signal was significantly improved when imidazole was absent. Under optimized conditions, a calibration curve was obtained with a linear range (10–100 µg/L). The limit of detection was 3 µg/L, while the limit of quantification was 10 µg/L. Finally the method was applied for the determination of AM in biological fluids successfully. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
Freestanding layered membrane–based devices have broad applications in highly efficient energy‐storage/conversion systems. The liquid–solid interface is considered as a unique yet versatile interface for constructing such layered membrane–based devices. In this review, the authors outline recent developments in the fabrication of soft materials to functionalize layered devices from the aspect of liquid–solid interfacial assembly and engineering arts. Seven liquid–solid interfacial assembly strategies, including flow‐directed, superlattice, solvent‐casting, evaporation‐induced, dip‐coating, spinning, and electrospinning assemblies, are comprehensively highlighted with a focus on their synthetic pathways, formation mechanisms, and interface engineering strategies. Meanwhile, recent representative works on layered membrane–based devices for electrochemical energy applications are presented. Finally, challenges and opportunities of this research area are highlighted in order to stimulate future developments. This review not only offers comprehensive and practical approaches to assemble liquid–solid interfaces with soft materials for various important layered electrochemical energy devices but also sheds lights on fundamental insights by thoughtful discussions on performance enhancement mechanisms of these electrochemical energy systems.  相似文献   

15.
A simple and sensitive flow injection chemiluminescence method has been developed for the determination of ferulic acid (FA) based on the significant enhancement effect of FA on the CL signal of the N‐bromobutanimide (NBS)–eosin–CrCl3 system in alkaline solution. Under optimum conditions, the enhanced CL intensity is linearly related to the concentration of FA in its pharmaceutical preparations and human plasma samples. The corresponding linear regression equations were established over the 4.0 × 10–10–1.0 × 10–7 g/mL for FA tablets and 2.0 × 10–10–1.0 × 10–7 g/mL for plasma samples. The limit of detection for FA tablets and limit of quantification for plasma samples were 2.8 × 10–10 g/mL (3 σ) and 3.04 × 10–10 g/mL (10 σ), respectively. A complete analysis could be performed within 40 s, including washing and sampling, giving a throughput of ≈90/h. The proposed method was successfully applied to the determination of FA in pharmaceutical preparations and human plasma samples with satisfactory results. The recoveries of pharmaceutical preparations and human plasma samples at three different concentrations were 97.8–102.6% and 96.7–104.0%, respectively. Furthermore, the possible mechanism of CL reactions was also discussed briefly. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
A variety of potentially inhibitory degradation products are produced during pretreatment of lignocellulosic biomass. Qualitative and quantitative interrogation of pretreatment hydrolysates is paramount to identifying potential correlations between pretreatment chemistries and microbial inhibition in downstream bioconversion processes. In the present study, corn stover, poplar, and pine feedstocks were pretreated under eight different chemical conditions, which are representative of leading pretreatment processes. Pretreatment processes included: 0.7% H2SO4, 0.07% H2SO4, liquid hot water, neutral buffer solution, aqueous ammonia, lime, lime with oxygen pressurization, and wet oxidation. Forty lignocellulosic degradation products resulting from pretreatment were analyzed using high performance liquid chromatography in combination with UV spectroscopy or tandem mass spectrometry detection (HPLC‐PDA‐MS/MS) and ion chromatography (IC). Of these compounds, several have been reported to be inhibitory, including furfural, hydroxymethyl furfural, ferulic acid, 3,4‐dihydroxybenzaldehyde, syringic acid among others. Formation and accumulation of monitored compounds in hydrolysates is demonstrated to be a function of both the feedstock and pretreatment conditions utilized. Biotechnol. Bioeng. 2010;107: 430–440. © 2010 Wiley Periodicals, Inc.  相似文献   

17.
Amycolatopsis sp. ATCC 39116 (formerly Streptomyces setonii) has shown promising results in converting ferulic acid (trans‐4‐hydroxy‐3‐methoxycinnamic acid; substrate), which can be derived from natural plant wastes, to vanillin (4‐hydroxy‐3‐methoxybenzaldehyde). After exploring the influence of adding vanillin at different times during the growth cycle on cell growth and transformation performance of this strain and demonstrating the inhibitory effect of vanillin, a solid–liquid two‐phase partitioning bioreactor (TPPB) system was used as an in situ product removal technique to enhance transformation productivity by this strain. The thermoplastic polymer Hytrel® G4078W was found to have superior partitioning capacity for vanillin with a partition coefficient of 12 and a low affinity for the substrate. A 3‐L working volume solid–liquid fed‐batch TPPB mode, using 300 g Hytrel G4078W as the sequestering phase, produced a final vanillin concentration of 19.5 g/L. The overall productivity of this reactor system was 450 mg/L. h, among the highest reported in literature. Vanillin was easily and quantitatively recovered from the polymers mostly by single stage extraction into methanol or other organic solvents used in food industry, simultaneously regenerating polymer beads for reuse. A polymer–liquid two phase bioreactor was again confirmed to easily outperform single phase systems that feature inhibitory or easily further degraded substrates/products. This enhancement strategy might reasonably be expected in the production of other flavor and fragrance compounds obtained by biotransformations. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 30:207–214, 2014  相似文献   

18.
Aqueous two‐phase systems (ATPS) are a liquid‐liquid extraction technology with clear process benefits; however, its lack of industrial embracement is still a challenge to overcome. Antibodies are a potential product to be recovered by ATPS in a commercial context. The objective of this work is to present a more integral approach of the different isolated strategies that have arisen in order to enable a practical, generic implementation of ATPS, using human immunoglobulin G (IgG) as experimental model. A microfluidic device is used for ATPS parameters preselection for product recovery. ATPS were continuously operated in a mixer‐settler device in one stage, multistage and multistage with recirculation configuration. Single‐stage pure IgG extraction with a polyethylene glycol (PEG) 3350‐phophates ATPS within continuous operation allowed a 65% recovery. Further implementation of a multistage platform promoted a higher particle partitioning reaching a 90% recovery. The processing of IgG from a cell supernatant culture harvest in a multistage system with top phase recirculation resulted in 78% IgG recovery in bottom phase. This work conjugates three not widely spread methodologies for ATPS: microfluidics, continuous and multistage operation.  相似文献   

19.
In recent years, more and more nanomaterials‐based chemiluminescence (CL) systems have appeared to improve the sensitivity and expand the scope of the analytical applications with the explosive growth and development of nanomaterials and technology. As a fascinating class of luminescent carbon nanomaterials, carbon dots (CDs) are now substantially studied in fabricating CL based assays due to their unique optical and mechanical properties. Herein, we summarize and highlight the current developments of CDs‐involved weak or ultraweak CL systems, as well as the corresponding mechanisms and proper applications in some fields. CDs can take part in the CL reactions as oxidants, emitting species directly involved in redox oxidation, energy acceptors of CL energy transfer, or even catalysts involving other luminophores. In fact, they always have more than one role in many cases, owing to the formation of various excited species with short life in CL systems. Therefore, in this review article, the most recent progress of the different CDs‐assisted CL systems including the mechanisms and applications are presented. Finally, the conclusions and future prospects of this field are also discussed. The significant features of the CDs‐based CL systems may open up new prospects and challenges in a wider range of fields.  相似文献   

20.
Chemiluminescence (CL) reactions are widely used for the detection and quantification of many types of analytes. Laccase has previously been proposed in CL reactions; however, its light emission behaviour has not been characterized. This study was conducted to characterize the laccase–luminol system, determine its kinetic parameters, and analyze the effects of protein and OHˉ concentration on the CL signal. Laccase from Coriolopsis gallica was combined with different concentrations of luminol (125 nM to 4 mM), and the enzyme kinetics were evaluated using diverse kinetic models. The laccase–luminol system was able to produce CL without an intermediate molecule, but it exhibited substrate-inhibition behaviour. A two-site random model was used and suggested that when the first luminol molecule was bound to the active site, laccase affinity for the second luminol molecule was increased. This inhibition effect could be avoided using a low luminol concentration. At 5 μM luminol concentration, 1 mg/ml (0.13 U) laccase is needed to achieve nearly 90% of the maximum CL signal, suggesting that the available luminol could not bind to all active sites. Furthermore, the concentration of NaOH negatively affected the CL signal. The laccase–luminol system represents an alternative to existing CL systems, with potential uses in molecular detection and quantification.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号