首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new method for the analysis of mebeverine hydrochloride (MEB) has been developed using a two‐chip device. The method is highly selective, sensitive, rapid and consumes minute amount of reagents. The developed method is free of interference from the degradation products of MEB and from common ingredients present in pharmaceutical formulations. The limit of detection was 0.043 µg/mL, and the limit of quantification was 0.138 µg/mL. The short analysis time per sample (20 s) allowed a large number of analyses to be performed within a very short time. Various samples were analyzed, including two different pharmaceutical formulations and a uniformity of content analysis for 20 tablets from a known batch and two biological samples at different concentrations. In addition, the method was compared with a validated high‐performance liquid chromatography (HPLC) method and the results clearly indicated the suitability of the developed method for routine analyses. A new mechanism for the tris(2,2'‐bipyridyl)ruthenium(II) (Ru(bpy)32+)‐peroxodisulfate (S2O82?) chemiluminescence (CL) system has also been proposed. The mechanism is based on photoinduced oxidation of Ru(bpy)32+ to Ru(bpy)33+ via the formation of Ru(bpy)32+* upon irradiation with visible light. S2O82? then oxidizes Ru(bpy)32+* to Ru(bpy)33+ and the analyte subsequently reduces the resultant Ru(bpy)33+ to Ru(bpy)32+*, which then produces the CL signal. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
Electrochemiluminescence (ECL) of tris(2,2’‐bipyridyl)ruthenium(II) [Ru(bpy)32+] is an active research area and includes the synthesis of ECL‐active materials, mechanistic studies and broad applications. Extensive research has been focused on this area, due to its scientific and practical importance. In this mini‐review we focus on the bio‐related applications of ECL. After a brief introduction to Ru(bpy)32+ ECL and its mechanisms, its application in constructing an effective bioassay is discussed in detail. Three types of ECL assay are covered: DNA, immunoassay and functional nucleic acid sensors. Finally, future directions for these assays are discussed. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
A simple, rapid and sensitive method has been developed for the analysis of fexofenadine (FEX) in pharmaceutical formulations, using a tris(1,10‐phenanthroline)–ruthenium(II) [Ru(phen)32+] peroxydisulphate chemiluminescence (CL) system in a multichip device. Various parameters that influence the CL signal intensity were optimized. These included pH, flow rates and concentration of reagents used. Under optimum conditions, a linear calibration curve in the range 0.05–5.0 µg/mL was obtained. The detection limit was found to be 0.001 µg/mL. The procedure was applied to the analysis of FEX in pharmaceutical products and was found to be free from interference from concomitants usually present in these preparations. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
A flow injection method with chemiluminescence detection is reported for the determination of vitamin A. The method is based on the enhancement effect of vitamin A on chemiluminescence of tris(2,2′‐bipyridyl)Ru(II)–Ce(IV) in acidic medium. The proposed procedure is used to quantitate vitamin A in the range 1.0–100 × 10?6 mol/L with a correlation coefficient of 0.9991 (n = 9) and relative standard deviation in the range 1.2–2.3% (n = 4). The limit of detection (3 × blank) was 8.0 × 10?8 mol/L with a sample throughput of 100/h. The effect of common excipients used in pharmaceutical formulations and some clinically important compounds was also studied. The method was applied to determine vitamin A in pharmaceutical formulations and the results obtained were in reasonable agreement with the amount quoted. The results were compared using spectrophotometric method and no significant difference was found between the results of the two methods at 95% confidence limit. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
It was found that meloxicam could enhance the chemiluminescence (CL) of the tris(2,2'‐bipyridine) ruthenium(II)–Ce(IV) system in the medium of sulfate acid. Based on this phenomenon a new flow‐injection system with chemiluminescent detection has been proposed for determination of meloxicam. Under optimum conditions, meloxicam had a good linear relationship with the CL intensity in the concentration range of 6.0  10?4 to 1.0 µg/mL and the detection limit was 3.7 × 10?4 µg/mL. The proposed method was applied to detect meloxicam in tablets and a satisfactory recovery was obtained. The possible mechanism for this CL system is also discussed in this paper. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
Huimin Liu  Heyou Han 《Luminescence》2009,24(5):300-305
Perturbation of the tris(2,2′‐bipyridine)ruthenium(II) [Ru(bpy)32+]‐catalyzed Belousov–Zhabotinsky (BZ) oscillating chemiluminescence (CL) reaction induced by l ‐cysteine was observed in the closed system. It was found that the CL intensity was decreased in the presence of l ‐cysteine. Meanwhile, oscillation period and oscillating induction period were prolonged. The sufficient reproducible induction period was used as parameter for the analytical application of oscillating CL reaction. Under the optimum conditions, the changes in the oscillating CL induction period were linearly proportional to the concentration of l ‐cysteine in the range from 8.0 × 10?7 to 5.0 × 10?5 mol L?1 (r = 0.997) with a detection limit of 4.3 × 10?7 mol L?1. The possible mechanism of l ‐cysteine perturbation on the oscillating CL reaction was also discussed. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
We developed a sensitive and robust electrogenerated chemiluminescence (ECL) flow sensor based on Ru(bpy)32+ immobilized with a Nepem‐211 perfluorinated ion exchange conductance membrane, which has robustness and stability under a wide range of chemical and physical conditions, good electrical conductivity, isotropy and a high exchange capacity for immobilization of Ru(bpy)32+. The flow sensor has been used as a post‐column detector in high‐performance liquid chromatography for determination of erythromycin and clarithromycin in honey and pork, and tricyclic antidepressant drugs in human urine. Under optimal conditions, the linear ranges were 0.03–26 ng/μL and 0.01–1 ng/μL for macrolides and tricyclic antidepressant drugs, respectively. The detection limits were 0.02, 0.01, 0.01, 0.06 and 0.003 ng/μL for erythromycin, clarithromycin, doxepin, amitriptyline and clomipramine, respectively. There is no post‐column reagent addition. In addition to the conservation expensive reagents, the experimental setup was simplified. The flow sensor was used for 2 years with high sensitivity and stability. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
A method for the determination of acetylcholine (ACh) has been developed using liquid chromatography with chemiluminescence detection. This method is based on the pre‐column alkaline cleavage of ACh to form trimethylamine (TMA) and the post‐column tris(2,2′‐bipyridyl)ruthenium(III) chemiluminescence detection of TMA. ACh was converted to TMA with high yield at 180°C in the presence of lithium hydroxide, and the produced TMA was separated on a cation‐exchange/reversed‐phase dual‐functional column using a mixture of 0.2 m potassium phosphate buffer (pH 5.9) and acetonitrile (20:1, v/v) as the mobile phase. The eluate was online mixed with acidic tris(2,2′‐bipyridyl)ruthenium(III) solution, and the generated chemiluminescence was detected. The detection limit (signal‐to‐noise ratio = 3) for ACh was 0.80 nmol/mL, which corresponded to 1.1 pmol TMA per injection volume of 5 µL. This is simple and robust method that does not need an expensive device and unstable enzymes, and was applied to the determination of ACh in pharmaceutical formulations. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
A sequential injection (SI) method was developed for the determination of chlorpheniramine (CPA), based on the reaction of this drug with tris(1,10‐phenanthroline)–ruthenium(II) [Ru(phen)32+] and peroxydisulphate (S2O82–) in the presence of light. The instrumental set‐up utilized a syringe pump and a multiposition valve to aspirate the reagents [Ru(phen)32+ and S2O82–] and a peristaltic pump to propel the sample. The experimental conditions affecting the chemiluminescence reaction were systematically optimized, using the univariate approach. Under the optimum conditions linear calibration curves of 0.1–10 µg/ml were obtained. The detection limit was 0.04 µg/ml and the relative standard deviation (RSD) was always < 5%. The procedure was applied to the analysis of CPA in pharmaceutical products and was found to be free from interferences from concomitants usually present in these preparations. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

10.
Erythromycin is determined in both urine and plasma samples using microbore reversed-phase liquid chromatography with tris(2,2′-bipyridyl)ruthenium(II) [Ru(bpy)32+] electrogenerated chemiluminescence (ECL) detection. Ru(bpy)32+ is included in the mobile phase thus eliminating band broadening caused by post-column reagent addition. Extra column band broadening is an important concern in microbore liquid chromatography due to the small peak volumes. Erythromycin was studied in both water and biological samples. The detection limit for erythromycin in standards is 0.01 μM or 50 fmol injected with a S/N of 3 and a linear working range that extends four orders of magnitude. Human urine and blood plasma were also studied. Urine samples were diluted and filtered before injection. Ultrafiltration was used to remove protein from blood plasma samples prior to injection. Erythromycin was selectively detected in the body fluid samples without any further sample preparation. The detection limits obtained for erythromycin in urine and plasma are 0.05 and 0.1 μM, respectively, for 5 μl injected on a 150×1 mm I.D. C18 column.  相似文献   

11.
A two‐electrode configuration powered by batteries was designed for a microchip capillary electrophoresis–electrochemiluminescence system. A home‐made working electrode for end‐column mode detection and wall‐jet configuration was made up of a platinum wire (0.3 mm diameter) and a quartz capillary (320 µm internal diameter). The platinum wire served as a pseudoreference electrode. The configuration of the detection power supply comprised two D‐size batteries (connected in series), a switch, and an adjustable resistor. The microchip consisted of two layers: the bottom layer was a glass sheet containing injection and separation channels; the upper layer was polydimethylsiloxane block. In order to reduce the loss of electrochemiluminescence signal, a coverslip (0.17 mm thickness) was used as the floor of the detection reservoir. The performance of the system was demonstrated by separation and detection of atropine, anisodamine and proline. The linear response for proline ranged from 5 µm to 100 µm (r = 0.9968), and the limit of detection was 1.0 µm (S/N = 3). The system was further applied to the measurement of atropine in atropine sulfate injection solutions with the limit of detection 2.3 µm . This new system is a potential tool in pharmaceutical analysis. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
A flow-injection chemiluminescence method for the determination of tetracycline was developed. The method is based on an enhancement by tetracycline of the chemiluminescence light emission of tris(2,2'-bipyridine)ruthenium(II). In sulphuric acid medium, the chemiluminescence is generated by the continuous oxidation of tris(2,2'-bipyridine)ruthenium(II) by cerium (IV) sulphate. The light-emission intensity is greatly enhanced in the presence of tetracycline. Under the optimum conditions, the calibration curve is linear over the range 3.75 x 10(-8) g/mL-1.5 x 10(-5) g/mL for tetracycline with the linear equation: deltaINT = 205.898 x C - 20.442 (R2 = 0.9974). The detection limit is 3.27 x 10(-8) g/mL. The proposed method was also successfully used to determine tetracycline in pharmaceutical formulation (mean recovery of tetracycline, 100.7%).  相似文献   

13.
Quantitative electrochemiluminescence (ECL) detection of a model protein, bovine serum albumin (BSA) was achieved via biotin–avidin interaction using an avidin-based sensor and a well-developed ECL system of tris(2,2′-bipyridine) ruthenium(II) derivative as label and tri-n-propylamine (TPA) as coreactant. To detect the protein, avidin was linked to the glassy carbon electrode through passive adsorptions and covalent interaction with carboxylate-terminated carbon nanotubes that was used as binder to immobilize avidin onto the electrode. Then, biotinylated BSA tagged with tris(2,2′-bipyridine) ruthenium(II) label was attached to the prepared avidin surface. After binding of BSA labeled with tris(2,2′-bipyridine) ruthenium(II) derivative to the surface-immobilized avidin through biotin, ECL response was generated when the self-assembled modified electrode was immersed in a TPA-containing electrolyte solution. Such double protein labeling protocol with a biotin label for biorecognition and ruthenium label for ECL detection facilitated the detection of protein compared to the classical double antibody sandwich format. The ECL intensity was linearly proportional to the feed concentration of BSA over two orders of magnitude in the range of 15 nM to 7.5 μM. The detection limit was estimated to be 1.5 nM. Further application to the lysozyme analysis was carried out to validate the present approach for an effective and favorable protocol for the quantitative detection of proteins. The dynamic range of lysozyme was from 0.001 g L−1 to 0.1 g L−1 and the detection limit was 0.1 mg L−1. Electrochemical impedance and cyclic voltammetric measurements along with some necessary control experiments were conducted to characterize the successful formation of self-assembled modified electrodes and to grant the whole detection process.  相似文献   

14.
A rapid, sensitive and simple electrochemiluminescence method for the determination of 5‐hydroxytryptamine (5‐HT) using capillary electrophoresis was proposed. The experimental parameters, including the detection potential, the concentration of Ru(bpy)32+, the concentration and pH of phosphate buffer for separation and detection, the injection voltage and time and the separation voltage on the determination of 5‐HT, were optimized. Under the optimized conditions, the linear concentration range for 5‐HT was 3.5 × 10‐9–5.1 × 10‐3 mol/L, with a detection limit of 5 × 10‐10 mol/L. The relative standard deviations (RSDs) of the ECL intensity and the migration times for six continuous injections of 1.0 µmol/L 5‐HT were 2.48% and 1.3%, respectively. The method was successfully applied to 5‐HT assay in samples of human serum in 5 min and the extraction recoveries with spiked serum samples were over 94.4%. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
Chemiluminescence (CL) detection for the determination of estrogen benzoate, using the reaction of tris(1,10–phenanthroline)ruthenium(II)–Na2SO3–permanganate, is described. This method is based on the CL reaction of estrogen benzoate (EB) with acidic potassium permanganate and tris(1,10–phenanthroline)ruthenium(II). The CL intensity is greatly enhanced when Na2SO3 is added. After optimization of the different experimental parameters, a calibration graph for estrogen benzoate is linear in the range 0.05–10 µg/mL. The 3 s limit of detection is 0.024 µg/mL and the relative standard deviation was 1.3% for 1.0 µg/mL estrogen benzoate (n = 11). This proposed method was successfully applied to commercial injection samples and emulsion cosmetics. The mechanism of CL reaction was also studied. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
The concentration of the ruthenium-based label is determined from the rate of hydrogen peroxide production elicited by photolysis. Electron transfer quenching of the photoexcited label by methyl viologen (1,1′-dimethyl-4,4′-bipyridinium dication, MV2+) and/or oxygen in the presence of EDTA generates hydrogen peroxide. Both flow injection and direct photolysis techniques were tested, with the latter showing better results. Direct photolysis is more sensitive, faster, requires only a 20 μl sample volume, uses only 30 mW laser power and shows a smaller background. The presence of 5% normal human serum in the sample did not interfere with the measurements. Linear calibration curves were obtained in the nanomolar concentration range for goat antimouse antibody labeled with the ruthenium complex. The determination of membrane-surface-bound labeled IgG is accomplished by direct photolysis of a membrane that covers a platinum microelectrode.  相似文献   

17.
A novel automated precolumn derivatization followed by separation using liquid chromatography for the determination of pseudoephedrine (PSE) by a microfluidic chemiluminescence detector has been developed. An on‐line derivatization procedure was utilized by converting PSE into a highly light emitting species in a Ru(bipy)32+‐peroxydisulphate chemiluminescence (CL) system by derivatizing it with a 1.0 M formaldehyde solution. The derivatized analyte was directly injected into a microbore high‐performance liquid chromatography (HPLC) system coupled to an on‐chip chemiluminescence detector. The newly developed highly selective, sensitive and fast HPLC‐CL method was validated and successfully applied for the analysis of PSE in pharmaceutical formulations and a human urine sample. The selectivity of the method is not only due to the HPLC separation but is also due to the highly selective detection principle of the Ru(bipy)32+‐peroxydisulphate CL system used. There was no interference observed from the common preservatives and excipients used in pharmaceutical preparations, which did not show any significant CL signal. The retention time of PSE was less than 3 min, and the detection limits and quantification limits were found to be 5.7 and 26.0 µg L–1, respectively. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
Rapid, simple and highly sensitive flow‐injection (FI) chemiluminescence (CL) and flow‐injection electrogenerated chemiluminescence (ECL) methods were developed for the determination of escitalopram oxalate (ESC), a selective serotonin reuptake inhibitor used as an antidepressant drug. The CL method was based on the CL reaction of ESC with acidic cerium(IV) and tris(2,2'‐bipyridyl)ruthenium(II) (Ru). Various experimental parameters affecting CL intensity were carefully studied and optimised. The method enabled the determination of 0.001‐50 µg/mL of ESC in bulk form with a correlation coefficient r = 0.9999. The limit of detection (LOD) was 0.01 ng/mL (S/N = 3). The ECL method was based on the ECL reaction of Ru with the drug in an acidic medium, permitting the determination of ESC in the range of 0.00001‐70 µg/mL with r = 0.9999 and LOD of 1 x 10‐4 ng/mL. The proposed methods were applied to the determination of ESC in commercial tablets. The results were compared statistically with those obtained from a published method using t‐ and F‐tests. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
In this study, electrochemiluminescence (ECL) of Ru(bpy)32+ (bpy = 2,2′‐bipyridyl) using ascorbic acid (H2A) as co‐reactant was investigated in an aqueous solution. When H2A was co‐existent in a Ru(bpy)32+‐containing buffer solution, ECL peaks were observed at a potential corresponding to the oxidation of Ru(bpy)32+, and the intensity was proportional to H2A concentration at lower concentration levels. The formation of the excited state *Ru(bpy)32+ was confirmed to result from the co‐reaction between Ru(bpy)33+and the intermediate of ascorbate anion radical (A•), which showed the maximum ECL at pH = 8.8. It is our first finding that the ECL intensity would be quenched significantly when the concentration of H2A was relatively higher, or upon ultrasonic irradiation. In most instances, quenching is observed with four‐fold excess of H2A over Ru(bpy)32+. The diffusional self‐quenching scheme as well as the possible reaction pathways involved in the Ru(bpy)32+–H2A ECL system are discussed in this study. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
A simple, rapid chemiluminescence (CL) method was described for the determination of piroxicam, a commonly used analgesic agent drug. A strong CL signal was detected when cerium(IV) sulphate was injected into tris‐(4,7‐diphenyl‐1,10‐phenanthrolinedisulphonic acid) ruthenium(II) (RuBPS)–piroxicam solution. The CL signal was proportional to the concentration of piroxicam in the range 2.8 × 10–8–1.2 × 10–5 mol/L. The detection limit was 2 × 10–8 mol/L and the relative standard deviation (RSD) was 3.7% (c = 7.0 × 10–7 mol/L piroxicam; n = 11). The proposed method was applied to the determination of piroxicam in pharmaceutical preparations in capsules, spiked serum and urine samples with satisfactory results. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号