首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
BackgroundAn autogenous arteriovenous fistula is the optimal vascular access for hemodialysis. In the case of brachiocephalic fistula, cephalic arch stenosis commonly develops leading to access failure. We have hypothesized that a contribution to fistula failure is low wall shear stress resulting from post-fistula creation hemodynamic changes that occur in the cephalic arch.MethodsTwenty-two subjects with advanced renal failure had brachiocephalic fistulae placed. The following procedures were performed at mapping (pre-operative) and at fistula maturation (8–32 weeks post-operative): venogram, Doppler to measure venous blood flow velocity, and whole blood viscosity. Geometric and computational modeling was performed to determine wall shear stress and other geometric parameters. The relationship between hemodynamic parameters and clinical findings was examined using univariate analysis and linear regression.ResultsThe percent low wall shear stress was linearly related to the increase in blood flow velocity (p < 0.01). This relationship was more significant in non-diabetic patients (p < 0.01) than diabetic patients. The change in global measures of arch curvature and asymmetry also evolve with time to maturation (p < 0.05).ConclusionsThe curvature and hemodynamic changes during fistula maturation increase the percentage of low wall shear stress regions within the cephalic arch. Low wall shear stress may contribute to subsequent neointimal hyperplasia and resultant cephalic arch stenosis. If this hypothesis remains tenable with further studies, ways of protecting the arch through control of blood flow velocity may need to be developed.  相似文献   

3.
Although atherosclerosis is a multifactorial disease, the role of hemodynamic information has become more important. Low and oscillating wall shear stress (WSS) that changes its direction is associated with the early stage of atherosclerosis. Several in vitro and in vivo models were proposed to reveal the relation between the WSS and the early atherosclerosis. However, these models possess technical limitations in mimicking real physiological conditions and monitoring the developmental course of the early atherosclerosis. In this study, a hypercholesterolaemic zebrafish model is proposed as a novel experimental model to resolve these limitations. Zebrafish larvae are optically transparent, which enables temporal observation of pathological variations under in vivo condition. WSS in blood vessels of 15 days post-fertilisation zebrafish was measured using a micro particle image velocimetry (PIV) technique, and spatial distribution of lipid deposition inside the model was quantitatively investigated after feeding high cholesterol diet for 10 days. Lipids were mainly deposited in blood vessel of low WSS. The oscillating WSS was not induced by the blood flows in zebrafish models. The present hypercholesterolaemic zebrafish would be used as a potentially useful model for in vivo study about the effects of low WSS in the early atherosclerosis.  相似文献   

4.
Flow-mediated dilation is aimed at normalization of local wall shear stress under varying blood flow conditions. Blood flow velocity and vessel diameter are continuous and opposing influences that modulate wall shear stress. We derived an index FMDv to quantify wall shear stress normalization performance by flow-mediated dilation in the brachial artery. In 22 fasting presumed healthy men, we first assessed intra- and inter-session reproducibilities of two indices pFMDv and mFMDv, which consider the relative peak and relative mean hyperemic change in flow velocity, respectively. Second, utilizing oral glucose loading, we evaluated the tracking performance of both FMDv indices, in comparison with existing indices [i.e., the relative peak diameter increase (%FMD), the peak to baseline diameter ratio (Dpeak/Dbase), and the relative peak diameter increase normalized to the full area under the curve of blood flow velocity with hyperemia (FMD/shearAUC) or with area integrated to peak hyperemia (FMD/shearAUC_peak)]. Inter-session and intra-session reproducibilities for pFMDv, mFMDv and %FMD were comparable (intra-class correlation coefficients within 0.521–0.677 range). Both pFMDv and mFMDv showed more clearly a reduction after glucose loading (reduction of ~45%, p≤0.001) than the other indices (% given are relative reductions): %FMD (~11%, p≥0.074); Dpeak/Dbase (~11%, p≥0.074); FMD/shearAUC_peak (~20%, p≥0.016) and FMD/shearAUC (~38%, p≤0.038). Further analysis indicated that wall shear stress normalization under normal (fasting) conditions is already far from ideal (FMDv << 1), which (therefore) does not materially change with glucose loading. Our approach might be useful in intervention studies to detect intrinsic changes in shear stress normalization performance in conduit arteries.  相似文献   

5.

In continuing the investigation of AAA hemodynamics, unsteady flow-induced stresses are presented for pulsatile blood flow through the double-aneurysm model described in Part I. Physiologically realistic aortic blood flow is simulated under pulsatile conditions for the range of time-average Reynolds numbers 50 h Re m h 300. Hemodynamic disturbance is evaluated for a modified set of indicator functions which include wall pressure ( p w ), wall shear stress ( w ), Wall Shear Stress Gradient (WSSG), time-average wall shear stress ( w *), and time-average Wall Shear Stress Gradient WSSG *. At peak flow, the highest shear stress and WSSG levels are obtained at the distal end of both aneurysms, in a pattern similar to that of steady flow. The maximum values of wall shear stresses and wall shear stress gradients are evaluated as a function of the time-average Reynolds number resulting in a fourth order polynomial correlation. A comparison between numerical predictions for steady and pulsatile flow is presented, illustrating the importance of considering time-dependent flow for the evaluation of hemodynamic indicators.  相似文献   

6.

Introduction

In the human placenta the maternal blood circulates in the intervillous space (IVS). The syncytiotrophoblast (STB) is in direct contact with maternal blood. The wall shear stress (WSS) exerted by the maternal blood flow on the STB has not been evaluated. Our objective was to determine the physiological WSS exerted on the surface of the STB during the third trimester of pregnancy.

Material and Methods

To gain insight into the shear stress levels that the STB is expected to experience in vivo, we have formulated three different computational models of varying levels of complexity that reflect different physical representations of the IVS. Computations of the flow fields in all models were performed using the CFD module of the finite element code COMSOL Multiphysics 4.4. The mean velocity of maternal blood in the IVS during the third trimester was measured in vivo with dynamic MRI (0.94±0.14 mm.s-1). To investigate if the in silico results are consistent with physiological observations, we studied the cytoadhesion of human parasitized (Plasmodium falciparum) erythrocytes to primary human STB cultures, in flow conditions with different WSS values.

Results

The WSS applied to the STB is highly heterogeneous in the IVS. The estimated average values are relatively low (0.5±0.2 to 2.3±1.1 dyn.cm-2). The increase of WSS from 0.15 to 5 dyn.cm-2 was associated with a significant decrease of infected erythrocyte cytoadhesion. No cytoadhesion of infected erythrocytes was observed above 5 dyn.cm-2 applied for one hour.

Conclusion

Our study provides for the first time a WSS estimation in the maternal placental circulation. In spite of high maternal blood flow rates, the average WSS applied at the surface of the chorionic villi is low (<5 dyn.cm-2). These results provide the basis for future physiologically-relevant in vitro studies of the biological effects of WSS on the STB.  相似文献   

7.
The aim of this study was to investigate how perceived stress may affect electroencephalographical (EEG) activity in a stress paradigm in a sample of 76 healthy participants. EEG activity was analyzed using multilevel modeling, allowing estimation of nested effects (EEG time segments within subjects). The stress paradigm consisted of a 3-minute pre-stimulus stress period and a 2-minute post-stimulus phase. At t=3 minutes, a single electrical stimulus was delivered. Participants were unaware of the precise moment of stimulus delivery and its intensity level. In the EEG time course of alpha activity, a stronger increase was observed during the post-stimulus period as compared to the pre-stimulus period. An opposite time course effect was apparent for gamma activity. Both effects were in line with a priori expectations and support the validity of this experimental EEG-stress paradigm. Secondly, we investigated whether interaction effects of stress and coping, as measured with the Perceived Stress Scale-10 questionnaire (PSS-10), could be demonstrated. A higher perceived stress score was accompanied by a greater increase in delta- and theta-activity during the post-stimulus phase, compared to low scores. In contrast, low coping capacity was associated with a stronger decrease in slow beta, fast beta and gamma activity during the post-stimulus phase. The results of the present article may be interpreted as proof-of-principle that EEG stress-related activity depends on the level of subjectively reported perceived stress. The inclusion of psychosocial variables measuring coping styles as well as stress-related personality aspects permits further examination of the interconnection between mind and body and may inform on the process of transformation from acute to chronic stress.  相似文献   

8.
Development of many conditions and disorders, such as atherosclerosis and stroke, are dependent upon hemodynamic forces. To accurately predict and prevent these conditions and disorders hemodynamic forces must be properly mapped. Here we compare a shear-rate dependent fluid (SDF) constitutive model, based on the works by Yasuda et al in 1981, against a Newtonian model of blood. We verify our stabilized finite element numerical method with the benchmark lid-driven cavity flow problem. Numerical simulations show that the Newtonian model gives similar velocity profiles in the 2-dimensional cavity given different height and width dimensions, given the same Reynolds number. Conversely, the SDF model gave dissimilar velocity profiles, differing from the Newtonian velocity profiles by up to 25% in velocity magnitudes. This difference can affect estimation in platelet distribution within blood vessels or magnetic nanoparticle delivery. Wall shear stress (WSS) is an important quantity involved in vascular remodeling through integrin and adhesion molecule mechanotransduction. The SDF model gave a 7.3-fold greater WSS than the Newtonian model at the top of the 3-dimensional cavity. The SDF model gave a 37.7-fold greater WSS than the Newtonian model at artery walls located immediately after bifurcations in the idealized femoral artery tree. The pressure drop across arteries reveals arterial sections highly resistive to flow which correlates with stenosis formation. Numerical simulations give the pressure drop across the idealized femoral artery tree with the SDF model which is approximately 2.3-fold higher than with the Newtonian model. In atherosclerotic lesion models, the SDF model gives over 1 Pa higher WSS than the Newtonian model, a difference correlated with over twice as many adherent monocytes to endothelial cells from the Newtonian model compared to the SDF model.  相似文献   

9.

Background

Bladder cancer is the fourth most common malignancy in men, with a recurrence rate of 33–64%. Tumor documentation during cystoscopy of the bladder is suboptimal and might play a role in these high recurrence rates.

Objective

In this project, a bladder registration and navigation system was developed to improve bladder tumor documentation and consequently increase reproducibility of the cystoscopy.

Materials/Methods

The bladder registration and navigation system consists of a stereo-tracker that tracks the location of a newly developed target, which is attached to the endoscope during cystoscopy. With this information the urology registration and navigation software is able to register the 3D position of a lesion of interest. Simultaneously, the endoscopic image is captured in order to combine it with this 3D position. To enable navigation, navigational cues are displayed on the monitor, which subsequently direct the cystoscopist to the previously registered lesion. To test the system, a rigid and a flexible bladder phantom was developed. The system''s robustness was tested by measuring the accuracy of registering and navigating the lesions. Different calibration procedures were compared. It was also tested whether system accuracy is limited by using a previously saved calibration, to avoid surgical delay due to calibration. Urological application was tested by comparing a rotational camera (fixed to the rotating endoscope) to a non-rotational camera (dangling by gravity) used in standard urologic practice. Finally, the influence of volume differences on registering and navigating was tested.

Results/Conclusion

The bladder registration and navigation system has an acceptable accuracy for bladder lesion registration and navigation. Limitations for patient determinants included changes in bladder volume and bladder deformation. In vivo studies are required to measure the effect of these limitations and functionality in urological practice as a tool to increase reproducibility of the cystoscopy.  相似文献   

10.

Introduction

Abnormal fluid mechanical environment in the pre-natal cardiovascular system is hypothesized to play a significant role in causing structural heart malformations. It is thus important to improve our understanding of the prenatal cardiovascular fluid mechanical environment at multiple developmental time-points and vascular morphologies. We present such a study on fetal great arteries on the wildtype mouse from embryonic day 14.5 (E14.5) to near-term (E18.5).

Methods

Ultrasound bio-microscopy (UBM) was used to measure blood velocity of the great arteries. Subsequently, specimens were cryo-embedded and sectioned using episcopic fluorescent image capture (EFIC) to obtain high-resolution 2D serial image stacks, which were used for 3D reconstructions and quantitative measurement of great artery and aortic arch dimensions. EFIC and UBM data were input into subject-specific computational fluid dynamics (CFD) for modeling hemodynamics.

Results

In normal mouse fetuses between E14.5–18.5, ultrasound imaging showed gradual but statistically significant increase in blood velocity in the aorta, pulmonary trunk (with the ductus arteriosus), and descending aorta. Measurement by EFIC imaging displayed a similar increase in cross sectional area of these vessels. However, CFD modeling showed great artery average wall shear stress and wall shear rate remain relatively constant with age and with vessel size, indicating that hemodynamic shear had a relative constancy over gestational period considered here.

Conclusion

Our EFIC-UBM-CFD method allowed reasonably detailed characterization of fetal mouse vascular geometry and fluid mechanics. Our results suggest that a homeostatic mechanism for restoring vascular wall shear magnitudes may exist during normal embryonic development. We speculate that this mechanism regulates the growth of the great vessels.  相似文献   

11.
PURPOSE: To explore the effects of computed tomography (CT) slice thickness and reconstruction algorithm on quantification of image features to characterize tumors using a chest phantom. MATERIALS AND METHODS: Twenty-two phantom lesions of known sizes (10 and 20 mm), shapes (spherical, elliptical, lobulated, and spiculated), and densities [-630, -10, and +100 Hounsfield Unit (HU)] were inserted into an anthropomorphic thorax phantom and scanned three times with relocations. The raw data were reconstructed using six imaging settings, i.e., a combination of three slice thicknesses of 1.25, 2.5, and 5 mm and two reconstruction kernels of lung and standard. Lesions were segmented and 14 image features representing lesion size, shape, and texture were calculated. Differences in the measured image features due to slice thickness and reconstruction algorithm were compared using linear regression method by adjusting three confounding variables (size, density, and shape). RESULTS: All 14 features were significantly different between 1.25 and 5 mm slice images. The 1.25 and 2.5 mm slice thicknesses were better than 5 mm for volume, density mean, density SD gray-level co-occurrence matrix (GLCM) energy and homogeneity. As for the reconstruction algorithm, there was no significant difference in uni-dimension, volume, shape index 9, and compactness. Lung reconstruction was better for density mean, whereas standard reconstruction was better for density SD. CONCLUSIONS: CT slice thickness and reconstruction algorithm can significantly affect the quantification of image features. Thinner (1.25 and 2.5 mm) and thicker (5 mm) slice images should not be used interchangeably. Sharper and smoother reconstructions significantly affect the density-based features.  相似文献   

12.

Introduction

Non-maturation and post-maturation venous stenosis are the primary causes of failure within arteriovenous fistulae (AVFs). Although the exact mechanisms triggering failure remain unclear, abnormal hemodynamic profiles are thought to mediate vascular remodelling and can adversely impact on fistula patency.

Aim

The review aims to clarify the role of shear stress on outward remodelling during maturation and evaluate the evidence supporting theories related to the localisation and development of intimal hyperplasia within AVFs.

Methods

A systematic review of studies comparing remodelling data with hemodynamic data obtained from computational fluid dynamics of AVFs during and after maturation was conducted.

Results

Outward remodelling occurred to reduce or normalise the level of shear stress over time in fistulae with a large radius of curvature (curved) whereas shear stress was found to augment over time in fistulae with a small radius of curvature (straight) coinciding with minimal to no increases in lumen area. Although this review highlighted that there is a growing body of evidence suggesting low and oscillating shear stress may stimulate the initiation and development of intimal medial thickening within AVFs. Further lines of evidence are needed to support the disturbed flow theory and outward remodelling findings before surgical configurations and treatment strategies are optimised to conform to them. This review highlighted that variation between the time of analysis, classification of IH, resolution of simulations, data processing techniques and omission of various shear stress metrics prevented forming pooling of data amongst studies.

Conclusion

Standardised measurements and data processing techniques are needed to comprehensively evaluate the relationship between shear stress and intimal medial thickening. Advances in image acquisition and flow quantifications coupled with the increasing prevalence of longitudinal studies commencing from fistula creation offer viable techniques and strategies to robustly evaluate the relationship between shear stress and remodelling during maturation and thereafter.  相似文献   

13.

Background

Anaemia is a common disorder. Most health providers in resource poor settings rely on physical signs to diagnose anaemia. We aimed to determine the diagnostic accuracy of pallor for anaemia by using haemoglobin as the reference standard.

Methodology/Principal Findings

In May 2007, we enrolled consecutive patients over 12 years of age, able to consent and willing to participate and who had a haemoglobin measurement taken within a day of assessment of clinical pallor from outpatient and medicine inpatient department of a teaching hospital. We did a blind and independent comparison of physical signs (examination of conjunctivae, tongue, palms and nailbed for pallor) and the reference standard (haemoglobin estimation by an electronic cell counter). Diagnostic accuracy was measured by calculating likelihood ratio values and 95% confidence intervals (CI) at different haemoglobin thresholds and area under the receiver operating characteristic curve. Two observers examined a subset of patients (n = 128) to determine the inter-observer agreement, calculated by kappa statistics. We studied 390 patients (mean age 40.1 [SD 17.08] years); of whom 48% were women. The haemoglobin was <7 g/dL in 8% (95% confidence interval, 5, 10) patients; <9 g/dL in 21% (17, 26) patients and <12 g/dL in 64% (60, 70) patients. Among patients with haemoglobin <7 g/dL, presence of severe tongue pallor yielded a LR of 9.87 (2.81, 34.6) and its absence yielded a LR of 0. The tongue pallor outperformed other pallor sites and was also the best discriminator of anaemia at haemoglobin thresholds of 7 g/dL and 9 g/dL (area under the receiver operating characteristic curves (ROC area  = 0.84 [0.77, 0.90] and 0.71[0.64, 0.76]) respectively. The agreement between the two observers for detection of anaemia was poor (kappa values  = 0.07 for conjunctival pallor and 0.20 for tongue pallor).

Conclusions/Significance

Clinical assessment of pallor can rule out and modestly rule in severe anaemia.  相似文献   

14.
15.

Purpose

The relationship between low endothelial shear stress (ESS) and coronary atherosclerosis is well established. ESS assessment so far depended on invasive procedures. The aim of this study was to demonstrate the relationship between ESS and coronary atherosclerosis by using non-invasive coronary computed tomography angiography (CTA) for computational fluid dynamics (CFD) simulations.

Methods

A total number of 7 consecutive patients with suspected coronary artery disease who received CTA and invasive angiography with IVUS analysis were included in this study. CTA examinations were performed using a dual-source scanner. These datasets were used to build a 3D mesh model. CFD calculations were performed using a validated CFD solver. The presence of plaque was assumed if the thickness of the intima-media complex exceeded 0.3 mm in IVUS. Plaque composition was derived by IVUS radiofrequency data analysis.

Results

Plaque was present in 32.1% of all analyzed cross-sections. Plaque prevalence was highest in areas of low ESS (49.6%) and high ESS (34.8%). In parts exposed to intermediate-low and intermediate-high ESS few plaques were found (20.0% and 24.0%) (p<0.001). Wall thickness was closely associated with local ESS. Intima-media thickness was 0.43±0.34mm in low and 0.38±0.32mm in high ESS segments. It was significantly lower when the arterial wall was exposed to intermediate ESS (0.25±0.18mm and 0.28 ± 0.20mm) (p<0.001). Fibrofatty tissue was predominately found in areas exposed to low ESS (p≤0.023).

Conclusions

In this study a close association of atherosclerotic plaque distribution and ESS pattern could be demonstrated in-vivo. Adding CFD analysis to coronary CTA offers the possibility to gather morphologic and physiologic data within one non-invasive examination.  相似文献   

16.

Background

Takayasu arteritis (TA) is a rare form of chronic inflammatory granulomatous arteritis of the aorta and its major branches. Late gadolinium enhancement (LGE) with magnetic resonance imaging (MRI) has demonstrated its value for the detection of vessel wall alterations in TA. The aim of this study was to assess LGE of the coronary artery wall in patients with TA compared to patients with stable CAD.

Methods

We enrolled 9 patients (8 female, average age 46±13 years) with proven TA. In the CAD group 9 patients participated (8 male, average age 65±10 years). Studies were performed on a commercial 3T whole-body MR imaging system (Achieva; Philips, Best, The Netherlands) using a 3D inversion prepared navigator gated spoiled gradient-echo sequence, which was repeated 34–45 minutes after low-dose gadolinium administration.

Results

No coronary vessel wall enhancement was observed prior to contrast in either group. Post contrast, coronary LGE on IR scans was detected in 28 of 50 segments (56%) seen on T2-Prep scans in TA and in 25 of 57 segments (44%) in CAD patients. LGE quantitative assessment of coronary artery vessel wall CNR post contrast revealed no significant differences between the two groups (CNR in TA: 6.0±2.4 and 7.3±2.5 in CAD; p = 0.474).

Conclusion

Our findings suggest that LGE of the coronary artery wall seems to be common in patients with TA and similarly pronounced as in CAD patients. The observed coronary LGE seems to be rather unspecific, and differentiation between coronary vessel wall fibrosis and inflammation still remains unclear.  相似文献   

17.
目的:探讨不同血清丙氨酸转氨酶(ALT)浓度对于Fibroscan诊断肝纤维化期和肝硬化期的肝硬度准确性的影响。方法:根据血清ALT浓度分为三组:A组ALT相似文献   

18.
Although molecular techniques have identified Helicobacter pylori in drinking water-associated biofilms, there is a lack of studies reporting what factors affect the attachment of the bacterium to plumbing materials. Therefore, the adhesion of H. pylori suspended in distilled water to stainless steel 304 (SS304) coupons placed on tissue culture plates subjected to different environmental conditions was monitored. The extent of adhesion was evaluated for different water exposure times, using epifluorescence microscopy to count total cell numbers. High shear stresses—estimated through computational fluid dynamics—negatively influenced the adhesion of H. pylori to the substrata (P < 0.001), a result that was confirmed in similar experiments with polypropylene (P < 0.05). However, the temperature and inoculation concentration appeared to have no effect on adhesion (P> 0.05). After 2 hours, H. pylori cells appeared to be isolated on the surface of SS304 and were able to form small aggregates with longer exposure times. However, the formation of a three-dimensional structure was only very rarely observed. This study suggests that the detection of the pathogen in well water described by other authors can be related to the increased ability of H. pylori to integrate into biofilms under conditions of low shear stress. It will also allow a more rational selection of locations to perform molecular or plate culture analysis for the detection of H. pylori in drinking water-associated biofilms.  相似文献   

19.
Convection-enhanced delivery (CED) is a technique to bypass the blood-brain barrier and deliver therapeutic agents into the brain. However, animal studies and preliminary clinical trials have reported reduced efficacy to transport drugs in specific regions, attributed mainly to backflow, in which an annular zone is formed outside the catheter and the fluid preferentially flows toward the surface of the brain rather than through the tissue toward the targeted area. In this study, a finite element model of backflow was updated by implementing the pre-stress generated during needle insertion, which allows considering the effect of needle insertion velocity during CED infusions in agarose gel. The nonlinear mechanical properties of the agarose solutions were obtained by fitting experimental data from stress-relaxation tests. Additional experimental measurements of backflow lengths were used to adjust the pre-stress model. The developed model was able to reproduce changes of backflow length under different insertions velocities and flow rates. These findings reveal the relevance of considering the pre-stress in the tissue located around the needle surface during CED infusions into the brain.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号