1.
A high-performance liquid chromatography procedure for detection and quantitation of ethylene glycol in serum is described. Ethylene glycol and internal standard are derivatized with benzoyl chloride under alkaline conditions, purified by solid-phase extraction and analyzed by HPLC with UV detection. Analytical recovery of ethylene glycol ranges between 96 and 103%. The calibration curve is linear from 20 to 2000 mg/l. The limits of detection and quantitation are 10 and 20 mg/l, respectively. Assay imprecision is 4.8% or less. The assay is free from common interferences and provides increased sensitivity, improved precision and extended linearity.  相似文献   

2.
A rapid high-performance liquid chromatography (HPLC) method was developed for determination of metformin, an oral antidiabetic agent, in plasma. Sample preparation entailed a 30-min centrifugation of plasma through a micron filter with direct injection of the protein-free ultrafiltrate into an HPLC system consisting of a cation-exchange extraction column (7.5×4.6 mm), a column switching valve, and a cation-exchange analytical column (250×4.6 mm). The eluent was monitored at 232 nm. Metformin was well resolved at a retention time of about 5 min. There was less than 2% loss of metformin during ultrafiltration and good linearity was established from 0.10 to 40 mg/l of metformin hydrochloride. The lower limit of quantitation was about 0.05 mg/l, at which concentration the signal-to-noise was above 10. The intra- and inter-assay coefficients of variation at plasma concentrations of metformin hydrochloride between 0.25 and 25 mg/l were typically 0.8–1.4% and 3.5–6.4%, respectively. This method offers a rapid sample preparation time and achieves excellent sensitivity without resorting to extraction and evaporation techniques.  相似文献   

3.
A stable isotope dilution gas chromatography-mass spectrometry (GC-MS) assay for the trace level determination of estriol in human plasma is described. Negative ion chemical ionization (NICI) MS is used for highly specific detection. The method involves derivatization of the phenolic hydroxyl to the pentafluorobenzyl ether derivative and subsequent reaction of the remaining hydroxyls with heptafluorobutyric anhydride. This derivative allows detection of the strikingly abundant phenolate ion under NICI conditions. [2,4,17beta]-2H(3)-labeled estriol was used as an internal standard. For high-level measurements (>313 ng/l) plasma was directly derivatized by extractive alkylation followed by heptafluorobutylation prior to analysis. A rapid and simple sample work up procedure was elaborated for trace level determinations (>5 ng/l plasma) using solid-phase extraction on C(18) with an absolute recovery of 92.9%. For low-level measurements, the calibration curve was linear in the range of 5 to 625 ng/l (r=0.99993). Inter-assay analytical precisions (RSDs) were 1.29, 2.30 and 2.89% at 39, 156 and 650 ng/l plasma, respectively. For high-level measurements, calibration curve linearity was observed in the range of 0.313 to 20 microg/l (r=0.99998). Inter-assay analytical precisions (RSDs) were 5.17, 1.92, 2.57 and 2.74% at 0.313, 0.625, 2.5 and 10 microg/l plasma, respectively. Postmenopausal plasma was used for spiked plasma samples. Sensitivity and specificity of the presented method allows adequate determination of estriol in human plasma samples.  相似文献   

4.
A screening procedure was developed for the identification and the quantification of eight quaternary nitrogen muscle relaxants, including d-tubocurarine, alcuronium, pancuronium, vecuronium, atracurium, mivacurium, rocuronium and mebezonium, in blood samples. The procedure involves ion-pair extraction with methylene chloride at pH 5.4, reversed-phase HPLC separation and electrospray ionization mass spectrometry detection. The procedure was validated in terms of linearity (0.9295 for all the target compounds at 0.1 mg/l). The screening test was found satisfactory and applied in two fatal deaths. In the first case, toxicological investigations on biological fluids collected during the autopsy revealed the presence of vecuronium (1.2 and 0.6 mg/l in blood and urine, respectively) and its desacetylated metabolite, 3-hydroxy-vecuronium (4.4 and 0.7 mg vecuronium equivalent/l in blood and urine, respectively). In the second forensic case, blood analysis showed high levels of mebezonium (6.5 mg/l). The developed procedure was found suitable for forensic investigations.  相似文献   

5.
A high-performance liquid chromatographic technique for ethyl alcohol determination in body fluids is proposed. Ethyl alcohol is quantitatively converted into acetaldehyde-phenylhydrazone by oxidation in the presence of alcohol dehydrogenase, nicotinamide–adenine dinucleotide and phenylhydrazine. The derivative is suitable for reversed-phase liquid chromatography and ultraviolet detection at 276 nm. The limits of linearity, detection and quantification as well as accuracy and reproducibility were investigated in water, serum and whole blood. Analytical responses were linear within the 0.008 to 5 g/l range, and the limit of quantification was 0.02 g/l both in aqueous standard and in biological matrix assays. Mean analytical recovery of ethyl alcohol in blood serum averaged 98.2±4.2%, imprecision (CV%) at 0.80 g/l was 2.2%, and the limit of quantification was 0.02 g/l. Serum concentrations of persons that avoided alcoholic beverages for a week were less than the limit of quantification. Ethyl alcohol concentrations in serum and whole blood compared well with those obtained by headspace gas chromatography. This simple and reliable procedure, which was also used for a urine assay, could be suitable for validation of the screening procedures used to monitor ethanol abuse.  相似文献   

6.
A simple, accurate and sensitive high-performance liquid chromatographic method with UV detection was carried out to measure plasma concentrations of mycophenolic acid. Following a simplified acid hydrolysis of the sample, the separation was carried out in 4 min using a Zorbax Eclipse C(8) reversed-phase column with a flow-rate of 1.5 ml/min, and monitoring the absorbance at 250 nm. Throughput was up to 100 samples in 24 h. Within the investigated concentration ranges of mycophenolic acid (0-100 mg/l), good linearity (r>0.99) was obtained. The method is sensitive (the limit of detection was about 20 microg/l) and precise (for 0.49 mg/l added to plasma, within-run C.V. was 2% and between-run was 4.2%; for 2.88 mg/l, within-run C.V. was 0.35% and between-run C.V. was 0.69%; for 24.38 mg/l, within-run C.V. was 0.77% and between-run C.V. was 3.1%). Analytical recoveries were 96% for 0.5 mg/l mycophenolic acid added to plasma, 100% for 12 mg/l and 102.5% for 24 mg/l.  相似文献   

7.
A method of analysis for the determination of alosetron in human plasma or serum has been developed. The method was fully automated using a laboratory robot in order to improve analytical precision, efficiency and safety. The assay involved solid-phase extraction with reversed-phase HPLC separation and fluorescence detection. A validation exercise over the concentration range of 0.1 to 20 ng/ml demonstrated the selectivity, linearity, sensitivity, accuracy, precision, extraction efficiency, ruggedness and stability of the method. The method has been applied in support of numerous human pharmacokinetic/biopharmaceutic studies over the last five years.  相似文献   

8.
The development of an analytical probe to monitor highly mutagenic picric acid (PA) carries enormous significance for the environment and for health. A novel, simple and rapid fluorescence analytical assay using sulfur‐doped graphene quantum dots (SGQDs) was designed for the highly sensitive and selective detection of PA. SGQDs were synthesized via simple pyrolysis of 3‐mercaptopropionic acid and citric acid and characterized using advanced analytical techniques. Fluorescence intensity (FI) of SGQDs was markedly quenched by addition of PA, attributed to the inner filter effect and dominating static quenching mechanism between the two, in addition to a significant colour change. The calibration curve of the proposed assay exhibited a favourable linearity between quenched FI and PA concentration over the 0.1–100 μΜ range with a lowest detection limit of 0.093 μΜ and a correlation coefficient of 0.9967. The analytical assay was investigated for detection of trace amounts of PA in pond and rain water samples and showed great potential for practical applications with both acceptable recovery (98.0–100.8%) and relative standard deviation (1.24–4.67%). Analytical performance of the assay in terms of its detection limit, linearity range, and recovery exhibited reasonable superiority over previously reported methods, thereby holding enormous promise as a simple, sensitive, and selective method for detection of PA.  相似文献   

9.
A method for the determination of piracetam in human plasma and urine by liquid chromatography with absorbance detection at 206 nm and isocratic elution is proposed. The assay involved a liquid-liquid extraction into hexane-2-propanol at pH 9.2. The calibration graphs were linear in the range 3–40 mg/l in plasma and 100–2000 mg/l in urine. Bias was negligible and coefficients of variation were less than 10% throughout the working range except at 100 mg/l in urine. The limits of quantification were 3 mg/l in plasma and 100 mg/l in urine. The assay was reliably used for pharmacokinetic studies in humans after administration of 800 mg of piracetam per os.  相似文献   

10.
A simple, sensitive and rapid high-performance liquid chromatographic (HPLC) procedure to determine total serum acyclovir concentrations is described. The assay involves a heat inactivation step at 56°C to prevent risk of infection, ultrafiltration as a pretreatment step prior to ion-pair reversed-phase liquid chromatography using guanosine as internal standard, and ultraviolet detection at 254 nm. This method has excellent recovery (97–100%), linearity (0.5–100 mg/l) and precision (1.2–8.0% coefficient of variation). The detection limit is 50 μg/l. The assay proved to be suitable for therapeutic drug monitoring of acyclovir.  相似文献   

11.
An improved high-performance liquid chromatographic (HPLC) method utilizing solid-phase extraction (SPE) and midbore chromatography was developed for the determination of ranitidine in human plasma. A mobile phase of 20 mM K2HPO4-acetonitrile-triethylamine (87.9:12.0:0.1, v/v) pH 6.0 was used with a phenyl analytical column and ultraviolet detection (UV). The method demonstrated linearity from 25 to 1000 ng/ml in 500 μl of plasma with a detection limit of 10 ng/ml. The method was utilized in a pharmacokinetic study evaluating the effects of pancreatico-biliary secretions on ranitidine absorption.  相似文献   

12.
A sensitive capillary electrophoretic method for the determination of carvedilol enantiomers in 100 μl of human plasma has been developed and validated. Carvedilol and the internal standard carazolol are isolated from plasma samples by liquid–liquid extraction using diethylether. A sensitive and selective detection is provided by helium–cadmium laser-induced fluorescence. The total analysis time is 17.5 min, about 30 min are needed for the sample preparation. The linearity of the assay ranges from 1.56 to 50 ng/ml per carvedilol enantiomer. The limits of quantification (LOQ) for the carvedilol enantiomers in 100 μl of human plasma are 1.56 ng/ml. The inter-day accuracy for R-carvedilol is between 95.8 and 103% (104% at LOQ) and for S-carvedilol between 97.1 and 103% (107% at LOQ); the inter-day precision values are between 3.81 and 8.64% (10.9% at LOQ) and between 5.47 and 7.86% (7.91% at LOQ) for R- and S-carvedilol, respectively. The small sample volume needed is especially advantageous for the application in clinical studies in pediatric patients. As an application of the assay concentration/time profiles of the carvedilol enantiomers in a 5-year-old patient receiving a test dose of 0.09 mg/kg carvedilol are reported.  相似文献   

13.
A molecularly imprinted solid-phase extraction coupled with high performance liquid chromatography (MISPE-HPLC) method was developed for rapid screening of mycophenolic acid (MPA) in human plasma. MPA imprinted polymers (MPA-MIP) were synthesized and then tested for their performance both in organic and in aqueous solution. MPA was selectively trapped and preconcentrated on the MPA-MIP sorbent using different loading and washing conditions. The good selectivity of MPA-MIP enabled further clean-up of the interfering components in human plasma. For the proposed MISPE-HPLC method, the linearity between responses (peak area) and concentration was found over the range of 1-100microg/ml with a linear regression coefficient (R(2)) of 0.9989. The limit of detection (LOD) and theoretical limit of quantification (LOQ) for MPA in plasma were 0.10 and 0.32microg/ml, respectively. The precisions were 7.3, 3.5 and 4.7% RSD for intra-day assay and 9.2, 4.1 and 5.5% RSD for inter-day reproducibility, respectively, at three concentration levels of MPA in spiked plasma (1, 10 and 100microg/ml). Both recoveries for the extraction (more than 74%) and for the analytical method (more than 87%) were acceptable for screening MPA in plasma samples. Twelve-hour pharmacokinetic profile of MPA for a renal transplant recipient receiving chronic oral dosing of 500mg mycophenolate mofetil (MMF) was investigated. Results indicated that this method could be applied for therapeutic drug monitoring of mycophenolic acid in patient plasma.  相似文献   

14.
A rapid capillary electrophoresis method for the quantification of gabapentin, a new anticonvulsant drug, in serum was developed. The assay involves derivatization of gabapentin with fluorescamine to provide a chromophore for UV-fluorescence detection. The migration time is about 11 min. The assay was linear between 0 and 20 mg/l. No other therapeutic drugs or amino acids interfered with the gabapentin peak. The relative standard deviation is 2.4% at a mean 11 mg/l (n=17). The mean serum level for 52 patients on this drug was 5.2 mg/l with a range of 0–12 mg/l.  相似文献   

15.
An assay was developed for the quantification of anastrozole [2,2′-[5-(1H-1,2,4-triazol-1-ymethyl)-1,3-phenylene]bis(2-methylpropiononitrile)] in human plasma using liquid-liquid extraction. Anastrozole and an internal standard were chromatographed and detected by gas chromatography with electron capture detection, using a combination temperature-pressure program. The range of the assay is 3 to 100 ng/ml. Anastrozole was quantified by comparing its peak area to that of an internal standard. A cross-validation of this assay was also successfully performed between several laboratories.  相似文献   

16.
A new method of determining coenzyme Q10 in human plasma was developed based on column-switching high performance liquid chromatography (HPLC). CoQ10 was quantitatively extracted into 1-propanol with a fast one-step extraction procedure, after centrifugation, the supernatant was cleaned on an octadecyl-bonded silica column and then transferred to reversed-phase column by a column-switching valve. Determination of CoQ10 was performed on a reversed-phase analytical column with ultraviolet detection at 275 nm and the mobile phase containing 10% (v/v) isopropanol in methanol at a flow-rate of 1.5 ml/min. The sensitivity of this method allows the detection of 0.1 microg/ml CoQ10 in plasma (S/N=3). The linearity between the concentration and peak height is from 0.05 to 20 mg/l. The reproducibility (R.S.D.%) of the method is less than 2% (within day) and less than 3% (between day), the average recovery is 100.9 + 2.1%, it takes only 30 min to complete an analysis procedure, suitable for the determination of CoQ10 in human plasma especially for batch analysis in clinical laboratories. Finally, the method was applied to determine the plasma CoQ10 levels in healthy subjects, hyperthyroid and hypothyroid patients.  相似文献   

17.
A specific, precise and accurate high-performance liquid chromatographic (HPLC) analytical method has been developed for the quantitative determination of different benzimidazole (BZD) anthelmintics in parasite material (Moniezia benedeni). Mebendazole (MBZ), oxibendazole (OBZ), flubendazole (FLBZ), albendazole (ABZ) ricobendazole (RBZ), albendazole sulphone (ABZSO(2)), fenbendazole (FBZ), oxfendazole (OFZ) and fenbendazole sulphone (FBZSO(2)) were measured simultaneously in M. benedeni, a sheep and cattle cestode parasite used as a model of the biological matrix. The recovery, linearity, precision, accuracy, limits of detection and quantification of the method were determined. Drug extraction from the parasite's tissue homogenate was performed using methanol (liquid phase extraction), and after solvent evaporation, the residual material was cleaned up by solid phase extraction prior to analysis by reversed-phase HPLC. The resolution of all the BZD molecules assayed was obtained on a C(18) reversed-phase (5 microm, 250 mm x 4.6 mm) column using acetonitrile and ammonium acetate as the mobile phase and ultraviolet (UV) detection at 292 nm. Regression analyses for all the BZD compounds assayed were linear at concentrations ranging from 1.61 to 64.21 nmol/100mg protein (triplicate determinations) showing correlation coefficients greater than 0.9922. The developed method is efficient for the simultaneous determination of several benzimidazole anthelmintic molecules in parasite material and useful for the ex vivo and in vivo characterisation of the kinetics of drug uptake/diffusion in target parasites, which seems to be relevant to optimise parasite control both in human and veterinary medicine.  相似文献   

18.
ortho-Cresol (o-C) and meta-cresol (m-C) are minor urinary metabolites of toluene, a widely used chemical with neurotoxicological properties. A new assay for their determination in human urine is here proposed. Urinary cresol sulphates and glucuronates are submitted to acid hydrolysis, urine is neutralized, added with o-cresols-d8, and analytes are sampled in the headspace of urine by SPME using a polydimethylsiloxane fiber. Analysis is performed by GC/MS using, for separation, either a SupelcoWax10 (for o-C) or a chiral CP Cresol (for o-C and m-C) column. The method is very specific, with a range of linearity 0-5.0 mg/l, within- and between-run precision, as coefficient of variation, <15% and <19%, limit of detection of 0.006 mg/l for o-C and 0.007 mg/l for m-C. The procedure is applied to the quantification of cresols in urine from workers exposed to toluene and from subjects belonging to the general population.  相似文献   

19.
A previously published method was used for the determination of piroxicam in plasma samples obtained from rat. The sample preparation involved liquid extraction, centrifugation and evaporation. Separation of piroxicam from internal standard occurred on a reversed-phase C18 column with a mobile phase consisting of methanol-phosphate buffer pH 2 (45:55). The detection limit of the assay was 0.02–20 μg/ml. The assay linearity was good (typically r = 0.9992). The method was applied for determination of piroxicam in rats after administration of an oral dose of 2 mg/kg piroxicam.  相似文献   

20.
We have established a robust, fully automated analytical method for the determination of indomethacin in rat plasma using a column-switching high-performance chromatographic system. The system consists of a precolumn and an analytical column connected in series via a switching valve. When a 50-microl portion of rat plasma containing a therapeutic level of indomethacin was applied directly to the system, the drug was automatically enriched in the precolumn (TSK BSA-ODS) by on-line solid-phase extraction. After elution of the plasma proteins, the analyte was automatically transferred to the analytical column (Zorbax Eclipse XDBC18) where chromatography was performed using isocratic elution and UV absorption detection at a wavelength of 254 nm. The separation mobile phase consisted of methanol-0.1% phosphoric acid (70:30, v/v) at a flow-rate of 1 ml/min. The calibration line for indomethacin showed good linearity in the range 50-10 000 ng/ml (r>0.999) with the detection quantification of 50 ng/ml (RSD=2.6%). Accuracy ranged from -0.62 to 3.22%, and the within- and between-day precision of the assay was better than 6% across the calibration range. The analytical sensitivity and accuracy of this assay is suitable for characterization of the pharmacokinetics of topical administration of imdomethacin to rats. The method has been successfully used to provide pharmacokinetic data in a large number of diverse pharmaceutical studies.  相似文献   