首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A simple, rapid and low cost sample preparation method was developed for quantification of docetaxel in mouse plasma by high-performance liquid chromatography/tandem mass spectrometry with paclitaxel as the internal standard. A small volume of plasma (40 microl) and one-step protein precipitation using methanol and acetonitrile (1:1 (v/v)) were used for sample preparation. The calibration curve for docetaxel in mouse plasma was linear over the range 25-2500 nM. The detection limit was 8 nM. The lower limit of quantitation is 25 nM. The intra- and inter-day precisions (CV) of analysis were 9.5 and 9.7% for the low quality control (LQC), 5.5 and 4.9% for the medium quality control (MQC) and 3.9 and 6.3% for the high quality control (HQC), respectively. The accuracy was 102.5% for LQC, 97.9% for MQC and 108.8% for HQC. This assay has now been applied to evaluation of mouse pharmacogenetics and other clinical pharmacology applications.  相似文献   

2.
PM01218 is a novel marine-derived alkaloid and has shown potent growth inhibitory activity against several human cancer cell lines. A rapid and sensitive high performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) method was developed and validated to quantify PM01218 in mouse and rat plasma. The lower limit of quantitation (LLOQ) was 0.05 ng/mL. The calibration curve was linear from 0.05 to 100 ng/mL (R(2)>0.999). The assay was specifically based on the multiple reaction monitoring (MRM) transitions at m/z 278.4-->184.2, no endogenous material interfaced with the analysis of PM01218 and its internal standard from blank mouse and rat plasma. The mean intra- and inter-day assay accuracy remained below 15 and 8%, respectively, for all calibration standards and QC samples. The intra- and inter-day assay precision was less than 12.8 and 8.5% for all QC levels, respectively. The utility of the assay was demonstrated by pharmacokinetics studies of i.v. (bolus) PM01218 on SD rats.  相似文献   

3.
A HPLC method with UV detection at 262nm was developed to analyze inositol hexanicotinate in rat plasma. Plasma samples were extracted with an equal volume of acetonitrile, followed by dilution with mobile phase buffer (5mM phosphate buffer, pH 6.0) to eliminate any solvent effects. Inositol hexanicotinate and the internal standard (mebendazole) were separated isocratically using a mobile phase of acetonitrile/phosphate buffer (35:65, v/v, pH 6.0) at a flow rate of 1.0mL/min and a reverse-phase XTerra MS C(18) column (4.6mmx150mm, 3.5microm). The standard curve was linear over a concentration range of 1.5-100.0microg/mL of inositol hexanicotinate in rat plasma. The HPLC method was validated with intra- and inter-day precisions of 1.55-4.30% and 2.69-21.5%, respectively. The intra- and inter-day biases were -0.75 to 19.8% and 2.58-22.0%, respectively. At plasma concentrations of 1.5-100microg/mL, the mean recovery of inositol hexanicotinate was 99.6%. The results of a stability study indicated that inositol hexanicotinate was unstable in rat plasma samples, but was stable in acetonitrile extracts of rat plasma for up to 24h at 4 degrees C. The assay is simple, rapid, specific, sensitive, and reproducible and has been used successfully to analyze inositol hexanicotinate plasma concentrations in a pharmacokinetic study using the rat as an animal model.  相似文献   

4.
A sensitive high-performance liquid chromatography-tandem mass spectrometry assay for thiocoraline, an anti-tumor depsipeptide, in mouse plasma is described. Echinomycin, a quinoxaline peptide, was used as an internal standard. Thiocoraline was recovered from the mouse plasma using protein precipitation with acetonitrile and followed by solid-phase extraction of the supernatant. The mobile phase consisted of methanol (0.1% formic acid)-water (0.1% formic acid) (90:10, v/v). The analytical column was a YMC C(18). The standard curve was linear from 0.1 to 50 ng/ml (R(2)>0.99). The lower limit of quantitation was 0.1 ng/ml. The assay was specific based on the multiple reaction monitoring transitions at m/z 1157-->215 and m/z 1101-->243 for thiocoraline and the internal standard, echinomycin, respectively. The mean intra- and inter-day assay accuracies remained below 5 and 12%, respectively, for all calibration standards and quality control (QC) samples. The intra- and inter-day assay precisions were less than 11.4 and 9.5% for all QC levels, respectively. The utility of the assay was demonstrated by a pharmacokinetic study of i.v. (bolus) thiocoraline on CD-1 mice. Thiocoraline was stable in mouse plasma in an ice-water bath for 6 h and for three freeze-thaw cycles. The reconstituted thiocoraline after extraction and drying sample process was stable in the autosampler for over 24 h. The assay was able to quantify thiocoraline in plasma up to 48 h following dose. Pharmacokinetic analysis showed that thiocoraline has distinct pharmacokinetic profiling when dosed in different formulation solutions. The assay is currently used to measure thiocoraline plasma concentrations in support of a project to develop a suitable formulation with a desirable pharmacokinetic profile.  相似文献   

5.
A rapid and sensitive liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of rimantadine in rat plasma. Rimantadine was extracted by protein precipitation with methanol, and the chromatographic separation was performed on a C(18) column. The total analytical run time was relatively short (4.6 min), and the limit of assay quantification (LLOQ) was 2 ng/mL using 50 microL of rat plasma. Rimantadine and the internal standard (amantadine) were monitored in selected ion monitoring (SIM) mode at m/z 180.2 and 152.1, respectively. The standard curve was linear over a concentration range from 2 to 750 ng/mL, and the correlation coefficients were greater than 0.999. The mean intra- and inter-day assay accuracy ranged from 100.1-105.0% to 100.3-104.0%, respectively, and the mean intra- and inter-day precision was between 1.3-2.3% and 1.8-3.0%, respectively. The developed assay method was successfully applied to a pharmacokinetic study in rats after oral administration of rimantadine hydrochloride at the dose of 20 mg/kg.  相似文献   

6.
Phenethyl isothiocyanate (PEITC) is a dietary compound present in cruciferous vegetables that has cancer-preventive properties. Our objective was to develop and validate a novel liquid chromatography-tandem mass spectrometry procedure to analyze PEITC concentrations in human plasma and urine. Following hexane extraction, ammonia was added to samples to derivatize PEITC to phenethylthiourea. Chromatographic separation was achieved on a C(18) column with acetonitrile/5 mM formic acid (60:40, v/v) as the mobile phase followed by tandem mass spectrometry detection in multiple reaction monitoring mode. Deuterium-labeled PEITC was used as the internal standard. The detection limit was 2 nM and calibration curves were linear from 7.8 to 2000 nM. The intra- and inter-day coefficients of variation were less than 5 and 10%, respectively. The intra- and inter-day accuracies ranged from 101.0 to 104.2% and from 102.8 to 118.6%, respectively. The recovery from spiked human plasma and urine ranged from 100.3 to 113.5% and from 98.3 to 103.9%, respectively. The assay was used to measure PEITC in plasma and urine samples obtained from subjects after consumption of 100g of watercress. This novel assay represents the first analytical method with the sensitivity and specificity to determine plasma and urine concentrations of PEITC.  相似文献   

7.
A rapid and sensitive liquid chromatography-tandem mass spectrometric method (LC-MS/MS) had been developed and validated to determine the concentrations of BPR0L075 in rat plasma. After a simple protein precipitation of plasma samples by acetonitrile, BPR0L075 was analyzed on a C(8) column at a flow rate of 0.5 mL/min. The mobile phase consisted of a mixture of 10 mM ammonium acetate containing 0.1% formic acid and acetonitrile (20:80, v/v). Both BPR0L075 (analyte) and the internal standard (BPR0L092) were determined using electro-spray ionization and the MS data acquisition was via multiple reactions monitoring (MRM) in positive scanning model. The MS/MS ion transitions monitored are m/z 342.2/195.2 and 312.5/165.2 for BPR0L075 and BPR0L092, respectively. The low limit of quantitation was 0.5 ng/mL. Each plasma sample was chromatographed within 5 min. The method was validated with respect to linearity, accuracy, precision, recovery, and stability. A good linear relationship was observed over the concentration range of 0.5-1000 ng/mL (r>0.9994). Absolute recoveries ranged from 63.45 to 68.34% in plasma at the concentrations of 2, 40, 400, and 800 ng/mL. The intra- and inter-day accuracy ranged from 92.04 to 111.80%. Intra- and inter-day relative standard deviations were 1.08-3.29% and 1.96-5.46%, respectively. This developed and validated assay method had been successfully applied to a pharmacokinetic study after intravenous injection of BPR0L075 in rats at a dose of 5mg/kg.  相似文献   

8.
A HPLC method without solvent extraction and using ultraviolet detection at 302 nm for the determination of omeprazole in rat plasma has been validated. Plasma samples after pretreatment with acetonitrile to effect deproteinization were dried under N(2) at 40 degrees C and reconstituted with mobile phase. The standard calibration curve for omeprazole was linear (r(2)=0.9999) over the concentration range of 0.02-3 microgml(-1). The intra- and inter-day assay variability range was 4.8-9.2% and 5.2-10.3% individually. This method has been successfully applied to a pharmacokinetic study of omeprazole in rats.  相似文献   

9.
A simple high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of abacavir and zidovudine (AZT) in rat plasma, amniotic fluid, fetal, and placental tissues. Extraction of abacavir, AZT, and the internal standard, azidouridine (AZDU) in amniotic fluid was carried out by protein precipitation. Extraction from plasma, fetal and placental homogenates was achieved by using a salting out technique. Chromatographic separation was performed using a C8 column (150 mm x 4.6 mm, 5 microm). The mobile phase consisted of 12% acetonitrile in 25 mM sodium phosphate buffer (adjusted to pH 7 with sodium hydroxide) for the fetus, placenta, plasma and amniotic fluid samples at a flow rate of 0.8 mL/min. The method was validated over the range from 0.05 to 50 microg/mL for both abacavir and AZT in the four biological matrices. The absolute recovery of abacavir ranged from 79 to 94%, while AZT recoveries ranged from 79 to 90% in the different biological matrices. The internal standard recovery ranged from 90 to 92%. Acceptable intra- and inter-day assay precision (<10% R.S.D.) and accuracy (<10% error) were observed over 0.05-50 microg/mL for all four matrices.  相似文献   

10.
A HPLC method for determination of trans-resveratrol concentrations in rat plasma was developed. Plasma samples were treated with acetonitrile to deposit proteins. The analysis used a Hypersil ODS(2) C(18) column (5 microm, 4.6 mm x 250 mm) and methanol/distilled water as the mobile phase (flow-rate=1 mL/min). The UV detection wavelength was 303 nm, and chlorzoxazone was used as the internal standard. The calibration curve was linear over the range of 0.02-40 microg/mL with a correlation coefficient of 0.9997. This concentration range corresponds well with the plasma concentrations of resveratrol in pharmacokinetic studies. There was 98.7%, 91.3% and 84.4% recovery from 0.02, 0.4 and 40 microg/mL plasma samples respectively. The R.S.D. of intra- and inter-day assay variations were all less than 12%. This HPLC assay is a quick, precise and reliable method for the analysis of resveratrol in pharmacokinetic studies.  相似文献   

11.
This paper describes an assay for the determination of glyphosate (GLYP), glyphosate metabolites [(aminomethyl) phosphonic acid] (AMPA), and glufosinate (GLUF) in human serum. After protein precipitation using acetonitrile and solid-phase extraction, serum samples were derivatized and analyzed by gas chromatography-mass spectrometry (GC-MS). The assay was linear over a concentration range of 3-100.0 microg/ml for GLYP, AMPA, and GLUF. The overall recoveries for the three compounds were >73%. The intra- and inter-day variations were <15%. Precision and accuracy were 6.4-10.6% and 88.2-103.7%, respectively. The validated method was applied to quantify the GLYP and AMPA content in the serum of a GLYP-poisoned patient. In conclusion, the method was successfully applied for the determination of GLYP and its metabolite AMPA in serum obtained from patient of GLYP-poisoning.  相似文献   

12.
A sensitive, stereoselective assay using solid phase extraction and LC-MS-MS was developed and validated for the analysis of (R)- and (S)-bupropion and its major metabolite (R,R)- and (S,S)-hydroxybupropion in human plasma and urine. Plasma or glucuronidase-hydrolyzed urine was acidified, then extracted using a Waters Oasis MCX solid phase 96-well plate. HPLC separation used an alpha(1)-acid glycoprotein column, a gradient mobile phase of methanol and aqueous ammonium formate, and analytes were detected by electrospray ionization and multiple reaction monitoring with an API 4000 Qtrap. The assay was linear in plasma from 0.5 to 200 ng/ml and 2.5 to 1000 ng/ml in each bupropion and hydroxybupropion enantiomer, respectively. The assay was linear in urine from 5 to 2000 ng/ml and 25 to 10,000 ng/ml in each bupropion and hydroxybupropion enantiomer, respectively. Intra- and inter-day accuracy was >98% and intra- and inter-day coefficients of variations were less than 10% for all analytes and concentrations. The assay was applied to a subject dosed with racemic bupropion. The predominant enantiomers in both urine and plasma were (R)-bupropion and (R,R)-hydroxybupropion. This is the first LC-MS/MS assay to analyze the enantiomers of both bupropion and hydroxybupropion in plasma and urine.  相似文献   

13.
A high-performance liquid chromatographic assay has been developed and validated for the determination of the anticancer agent CI-980 in plasma samples from pediatric patients. After ether extraction from alkaline plasma, the CI-980 was chromatographed on a (R)-N-(3,5-dinitrobenzoyl)phenylglycine stationary phase using a mobile phase composed of hexane–isopropanol (70:30, v/v) modified with 1% acetonitrile. The method was linear over a 0.25 to 25.00 ng/ml range and the intra- and inter-day coefficients of variation (C.V.s) were less than 15%. The method was applied to the determination of the plasma concentration–time profile for a pediatric patient receiving 3.5 mg/m2 of CI-980 per day as a continuous 72-h infusion.  相似文献   

14.
A sensitive stereoselective bioanalytical liquid chromatographic assay with mass spectrometric detection (LC-MS) was developed and validated for the on-line extraction and quantification of R- and S-methadone and the primary metabolite R- and S-2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) from human plasma. Deproteinized plasma was injected directly onto a small C8 column, washed and then back-flushed using a column switching valve and a second pump onto an alpha1-acid glycoprotein analytical column, and enantioselective separation achieved using a mobile phase gradient of methanol and ammonium formate. Analytes were validated over a range of 0.1-25 ng/ml R- and S-EDDP and 0.1-100ng/ml R- and S-methadone, respectively. Unweighted standard curves were linear over this concentration range (regression coefficients > 0.999). Quality control samples were evaluated at 1, 5, 12.5 ng/ml R- and S-EDDP and 1, 10, 50 ng/ml R- and S-methadone. Intra- and inter-day accuracy was >95%, and intra- and inter-day coefficients of variation were less than 10% for all analytes and concentrations. This assay represents the only method currently available which combines on-line extraction and achieves chiral separation of both methadone and EDDP from plasma, and offers improvements in sensitivity over existing methods.  相似文献   

15.
A sensitive and reproducible HPLC method for quantitative determination of puerarin (PUE) in rat plasma was developed and validated using 4-hydroxybenzaldehyde as an internal standard. The separation of PUE was performed on a CAPCELL PAK C18 column by gradient elution with 0.2% aqueous phosphoric acid and acetonitrile as the mobile phase. The method was validated and found to be linear in the range of 80-12,000ng/mL. The limit of quantification was 80ng/mL based on 100μL of plasma. The variations for intra- and inter-day precision were less than 8.3%, and the accuracy values were between 98% and 105.2%. The extraction recoveries were more than 85%. The method was successfully applied in the comparative study of pharmacokinetics of PEGylated puerarin (PEG-PUE) versus PUE in rats. Compared with PUE, PEG-PUE showed a 5.2-fold increase in half-life of PUE and a 4.7-fold increase in mean residence time. In addition, this method was also successfully applied to determine the low plasma concentration of PUE regenerated from PEG-PUE in vitro.  相似文献   

16.
A selective and sensitive method has been developed and validated for simultaneous quantification of methylephedrine and noscapine in human plasma. Analytes were extracted from human plasma samples by liquid-liquid extraction, separated on a Diamonsil C18 column and detected by tandem mass spectrometer with an atmospheric pressure chemical ionization (APCI) interface. Diphenhydramine was used as the internal standard (I.S.). The method was found to be precise and accurate within the linear range 0.1-100 ng/ml for each analyte. The intra- and inter-day relative standard deviations (R.S.D.s) were below 5.2% for methylephedrine and 6.7% for noscapine. The inter-day relative error (RE) as determined from quality control samples (QCs) was less than 3.0% for each analyte. The assay was successfully employed in a pharmacokinetic study after an oral administration of a multicomponent formulation containing 20 mg DL-methylephedrine hydrochloride, 16 mg noscapine, 300 mg paracetamol and 1mg of chlorpheniramine maleate.  相似文献   

17.
A rapid and sensitive liquid chromatography-tandem mass spectrometric (LC-MS-MS) method for the determination of metformin in human plasma using phenformin as internal standard has been developed and validated. Sample preparation of plasma involved acidification with acetic acid, deproteination with acetonitrile and washing with dichloromethane. Samples were then analyzed by HPLC on a short Nucleosil C18 column (5 microm, 50 mm x 4.6 mm i.d.) using a mobile phase consisting of acetonitrile:methanol:10mM ammonium acetate pH 7.0 (20:20:60, v/v/v) delivered at 0.65 ml/min. Detection was performed using an Applied Biosystems Sciex API 4000 mass spectrometer set at unit resolution in the multiple reaction monitoring (MRM) mode. Atmospheric pressure chemical ionization (APCI) was used for ion production. The assay was linear over the range 1-2000 ng/ml with intra- and inter-day precision of <8.6% and accuracy in the range 91-110%. The limit of detection was 250 pg/ml in plasma. The method was successfully applied to a clinical pharmacokinetic study of an extended-release tablet of metformin hydrochloride (500 mg) administered as a single oral dose.  相似文献   

18.
A high-performance liquid chromatographic assay has been developed and validated for the determination of the antitumor agent depsipeptide (FR-901228) in plasma samples from patients with advanced cancer. After the plasma proteins were precipitated with acetonitrile, the supernatant was extracted with ethylacetate. Depsipeptide was chromatographed on two serial octadecylsilica stationary phases using a mobile phase consisting of acetonitrile–potassium phosphate buffer (0.03 M, pH 3) (27:73, v/v), at a flow-rate of 2.0 ml/min and at ambient temperature. The method was linear over a 50 to 2000 ng/ml range and the intra- and inter-day coefficients of variations were less than 8%. The method was applied to the determination of the plasma concentration–time profile for 14 patients with advanced cancer receiving from 1 to 7.5 mg/m2 of depsipeptide per day as a continuous 4-h infusion.  相似文献   

19.
Two LC-ESI–MS and CID-MS/MS methods were developed and validated for pharmacokinetic studies of the novel oral taxane derivatives IDN 5738 and IDN 5839, used for preclinical evaluation in mice. The analysis requires 100 μL of plasma sample, involves the addition of an internal standard and protein precipitation with 0.1% HCOOH in acetonitrile. The HPLC separation was obtained on Sunfire C18 column and Selected Reaction Monitoring technique was used to quantify the taxanes. The recoveries were more than 90%; the methods were linear over the validated concentrations range of 25–1500 ng/mL for IDN 5738 and 25–5000 ng/mL for IDN 5839 and had a limit of detection of 0.14 and 0.25 ng/mL, respectively. The inter-day coefficient of variation (CV%) of the calibration standards ranged between 1.3 and 7.2% for IDN 5738 and between 0.0 and 9.0% for IDN 5839 and the mean accuracy was in the range 85.3–112.0% for IDN 5738 and between 80.0 and 111.0% for IDN 5839. Moreover, analysing quality control plasma samples on three different days, the methods resulted precise and accurate showing intra- and inter-day CV within 12% for both analytes, and accuracy of 92.0–113.3% and 85.9–105.7% for IDN 5738 and IDN 5839, respectively. With these methods, we studied for the first time, the pharmacokinetics of the two taxanes showing for both, good oral bioavailability (>50%).  相似文献   

20.
A sensitive and specific method was developed and validated for the quantitation of quercetin in human plasma and urine. The application of liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a TurboIonspray (TIS) interface in negative mode under multiple reactions monitoring was investigated. Chromatographic separation was achieved on a C12 column using a mobile phase of acetonitrile/water with 0.2% formic acid (pH 2.4) (40/60, v/v). The detection limit was 100 pg/ml and the lower limit of quantification was 500 pg/ml for plasma samples; the detection limit was 500 pg/ml and the lower limit of quantification was 1 ng/ml for urine samples. The calibration curve was linear from 1 to 800 ng/ml for plasma samples and was linear from 1 to 200 and 50 to 2000 ng/ml for urine samples. All the intra- and inter-day coefficients of variation were less than 11% and intra- and inter-day accuracies were within +/-15% of the known concentrations. This represents a LC/MS/MS assay with the sensitivity and specificity necessary to determine quercetin in human plasma and urine. This assay was used to determine both parent quercetin and the quercetin after enzymatic hydrolysis with beta-glucuronidase/sulfatase in human plasma and urine samples following the ingestion of quercetin 500 mg capsules.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号