首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Rimonabant is the first therapeutically relevant cannabinoid antagonist, licensed in Europe for treatment of obesity when a risk factor is associated. The objective of this study was to develop and validate a method for measurement of rimonabant in human plasma and hair using liquid chromatography coupled to mass spectrometry (LC-MS/MS). Rimonabant and AM-251 (internal standard) were extracted from 50muL of plasma or 10mg of hair using diethylether. Chromatography was performed on a 150mmx2.1mm C18 column using a mobile phase constituted of formate buffer/acetonitrile. Rimonabant was ionized by electrospray in positive mode, followed by detection with mass spectrometry. Data were collected either in full-scan MS or in full-scan MS/MS mode, selecting the ion m/z 463.1 for rimonabant and m/z 555.1 for IS. The most intense product ion of rimonabant (m/z 380.9) and IS (m/z 472.8) were used for quantification. Calibration curves covered a range from 2.5 (lower limit of quantification) to 1000.0ng/mL (upper limit of quantification) in plasma and from 2.5 to 1000.0pg/mg in hair. Validation results demonstrated that rimonabant could be accurately and precisely quantified in both matrixes: accuracy and precision were within 85-115% and within 15% of standard deviation, respectively. Stability studies in plasma showed that rimonabant was stable during the assay procedure, but a 30% decrease was observed for one concentration after 3 weeks at -20 degrees C. This simple and robust LC-MS/MS method can be used for measuring rimonabant concentrations in human plasma and hair either in clinical or in forensic toxicology.  相似文献   

2.
Carbamazepine (CBZ) and oxcarbazepine (OXCBZ) are both antiepileptic drugs, which are prescribed as first-line drugs for the treatment of partial and generalized tonic-clonic epileptic seizures. In this paper, a specific and sensitive liquid chromatography-electrospray ionization mass spectrometry method was described for the simultaneous determination of carbamazepine (CBZ), oxcarbazepine (OXCBZ) and eight of their metabolites [CBZ-10,11-epoxide (CBZ-EP), 10,11-dihydro-10,11-trans-dihydroxy-carbamazepine (DiOH-CBZ), 10-hydroxy-10,11-dihydroCBZ (10-OH-CBZ), 2-hydroxycarbamazepine (2-OH-CBZ), 3-hydroxycarbamazepine (3-OH-CBZ), iminostilbene (IM), acridone (AO) and acridine (AI)] in human plasma. The work-up procedure involved a simple precipitation with acetone. Separation of the analytes was achieved within 50 min using a Zorbax eclipse XD8 C8 analytical column. The mobile phase consisted of a mixture of acetonitrile-formate buffer (2 mM, pH 3). Detection was performed using a quadrupole mass spectrometer fitted with an electrospray ion source. Mass spectrometric data were acquired in single ion recording mode at m/z 237 for CBZ, m/z 180 for CBZ-EP and AI, m/z 236 for OXCBZ, m/z 237 for 10-OH-CBZ, m/z 253 for 2-OH-CBZ, 3-OH-CBZ and DiOH-CBZ, m/z 196 for AO and m/z 194 for IM. For all analytes, the drug/internal standard peak height ratios were linked via a quadratic relationship to plasma concentrations. The extraction recovery averaged 90% for CBZ, 80% for OXCBZ and was 80-105% for the metabolites. The lower limit of quantitation was 0.5mg/l for CBZ, 0.4 mg/l for OXCBZ and ranged from 0.02 to 0.3 mg/l for the metabolites. Precision ranged from 2 to 13% and accuracy was between 86 and 112%. This method was found suitable for the analysis of plasma samples collected during therapeutic drug monitoring of patients treated with CBZ or OXCBZ.  相似文献   

3.
A sensitive and reliable method was developed to quantitate phenylephrine in human plasma using liquid chromatography-electrospray tandem mass spectrometry. The assay was based on solid-phase extraction with C18 cartridges and hydrophilic interaction chromatography performed on a pentafluorophenylpropylsilica column (50 mm x 4 mm, 3 microm particles), the mobile phase consisted of methanol-10 mM ammonium acetate (90:10, v/v). Quantification was through positive-ion mode and selected reaction monitoring at m/z 168.1-->135.0 for phenylephrine and m/z 182.1-->135.0 for internal standard etilefrin, respectively. The lower limit of quantitation was 51 pg/ml using 0.25 ml of plasma and linearity was observed from 51 to 5500 pg/ml. Within-day and between-day precision expressed by relative standard deviation was less than 12% and inaccuracy did not exceed 8% at all levels. The assay was applied to the analysis of samples from a pharmacokinetic study.  相似文献   

4.
In order to study the biosynthesis of agatharesinol, a norlignan, l-phenylalanine-[ring-2,3,4,5,6-2H] and trans-cinnamic acid-[ring-13C6] were administered to fresh sapwood sticks of Cryptomeria japonica (sugi, Japanese cedar), that is, the labeled precursors were allowed to be absorbed through the tangential section of the wood sticks. The wood sticks were then maintained in high humidity desiccators for approximately 20 d after which ethyl acetate (EtOAc) extracts of the wood sticks were analyzed by gas chromatography-mass spectrometry (GC-MS). Native agatharesinol (trimethylsilylated) produces an m/z 369 ion and an m/z 484 ion that are characteristic of its structure. Agatharesinol formed in the sapwood sticks treated with the deuterium-labeled l-phenylalanine generated both of these ions together with m/z 373 and 377 ions (m/z 369+4 and +8, respectively), and also m/z 488 and 492 ions (m/z 484+4 and +8, respectively). Generation of m/z 373 and 488 ions is attributed to the substitution by deuterium of the four hydrogen atoms of either of the p-hydroxyphenyl rings of agatharesinol, and that of m/z 377 and 492 ions is attributed to the substitution by deuterium of the eight hydrogen atoms of both p-hydroxyphenyl rings. In the administration of the 13C-labeled trans-cinnamic acid, m/z 375 and 381 ions (m/z 369+6 and +12, respectively), and also m/z 490 and 496 ions (m/z 484+6 and +12, respectively) were found, indicating that either aromatic ring or both aromatic rings of agatharesinol were 13C-labeled. Consequently, assimilation of the labeled precursors into agatharesinol was clearly detected, and an experimental procedure for studies on the biosynthesis was developed.  相似文献   

5.
We report on the quantitative determination of acetaminophen (paracetamol; NAPAP-d(0)) in human plasma and urine by GC-MS and GC-MS/MS in the electron-capture negative-ion chemical ionization (ECNICI) mode after derivatization with pentafluorobenzyl (PFB) bromide (PFB-Br). Commercially available tetradeuterated acetaminophen (NAPAP-d(4)) was used as the internal standard. NAPAP-d(0) and NAPAP-d(4) were extracted from 100-μL aliquots of plasma and urine with 300 μL ethyl acetate (EA) by vortexing (60s). After centrifugation the EA phase was collected, the solvent was removed under a stream of nitrogen gas, and the residue was reconstituted in acetonitrile (MeCN, 100 μL). PFB-Br (10 μL, 30 vol% in MeCN) and N,N-diisopropylethylamine (10 μL) were added and the mixture was incubated for 60 min at 30 °C. Then, solvents and reagents were removed under nitrogen and the residue was taken up with 1000 μL of toluene, from which 1-μL aliquots were injected in the splitless mode. GC-MS quantification was performed by selected-ion monitoring ions due to [M-PFB](-) and [M-PFB-H](-), m/z 150 and m/z 149 for NAPAP-d(0) and m/z 154 and m/z 153 for NAPAP-d(4), respectively. GC-MS/MS quantification was performed by selected-reaction monitoring the transition m/z 150 → m/z 107 and m/z 149 → m/z 134 for NAPAP-d(0) and m/z 154 → m/z 111 and m/z 153 → m/z 138 for NAPAP-d(4). The method was validated for human plasma (range, 0-130 μM NAPAP-d(0)) and urine (range, 0-1300 μM NAPAP-d(0)). Accuracy (recovery, %) ranged between 89 and 119%, and imprecision (RSD, %) was below 19% in these matrices and ranges. A close correlation (r>0.999) was found between the concentrations measured by GC-MS and GC-MS/MS. By this method, acetaminophen can be reliably quantified in small plasma and urine sample volumes (e.g., 10 μL). The analytical performance of the method makes it especially useful in pediatrics.  相似文献   

6.
A fast, sensitive and accurate method for the determination of gemcitabine (difluorodeoxycytidine; dFdC) and deoxycytidine (CdR) in human plasma/tissue was developed using LC-MS/MS techniques. Effectiveness of the method is illustrated with the analysis of plasma from a phase I trial of dFdC administered as a 24h infusion. The method was developed using (15)N(3) CdR as an internal standard across the concentration range of 1-500ng/ml, using a cold alcohol-protein precipitation followed by desorption with freeze drying. Sample clean-up for LC-MS/MS analysis was performed by an innovative liquid/liquid back extraction with ethyl acetate and water. Chromatography was performed using a Chrompak-spherisorb-phenyl-column (3.1mmx200mm, 5microm) with a 50mM formic acid: acetonitrile (9:1) mobile phase eluted at 1ml/min. Extracted samples were observed to be stable for a minimum of 48h after extraction when kept at 4 degrees C. Detection was performed using an atmospheric pressure chemical ionization (APCI) source and mass spectrometric positive multi-reaction-monitoring-mode (+MRM) for dFdC (264 m/z; 112 m/z), CdR (228 m/z; 112 m/z), and (15)N(3) CdR (231 m/z; 115 m/z) at an ion voltage of +3500V. The accuracy, precision and limit-of-quantitation (LOQ) were as follows: dFdC: 99.8%, +/-7.9%, 19nM; CdR: 100.0%, +/-5.3%, 22nM, linear range LOQ to 2microM. During 24h infusion dFdC levels were detected with no interference from either CdR or difluorodeoxyuridine (dFdU). CdR co-eluted with dFdC but selectivity demonstrated no "crosstalk" between the compounds. In conclusion the analytical assay was very sensitive, reliable and robust for the determination of plasma and tissue concentrations of dFdC and CdR.  相似文献   

7.
Nitric oxide (NO), the endogenous modulator of vascular tone and structure, originates from oxidation of L-arginine catalysed by NO synthase (NOS). The L-arginine derivative L-homoarginine serves as an alternative NOS substrate releasing NO, competing with L-arginine for NOS, arginase, and arginine transport. In the present article we report a liquid chromatography-tandem mass spectrometric (LC-tandem MS) method for the determination of L-homoarginine in human plasma by stable-isotope dilution. L-[(13)C(6)]-Homoarginine was used as internal standard. This method provides high sample throughput of 25-μl aliquots of plasma with an analysis time of 4 min using LC-tandem MS electrospray ionisation in the positive mode (ESI+). Specific transitions for L-homoarginine and L-[(13)C(6)]-homoarginine were m/z 245 → m/z 211 and m/z 251 → m/z 217, respectively. The mean intra- and interassay CVs were 7.4 ± 4.5% (±SD) for 0.1-50 μmol/L and 7.5 ± 2.0% for 2 and 5 μmol/L, respectively. Applying this method, a mean plasma concentration of L-homoarginine of 2.5 ± 1.0 μmol/L was determined in 136 healthy humans.  相似文献   

8.
A simple, rapid and specific high-performance liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS) has been developed and validated for the determination of ketoconazole in human plasma. The method used diethyl ether to extract the ketoconazole and the internal standard (I.S.) R51012 from alkalinized plasma sample. The LC separation was on a C(18) column (50 x 3 mm, 5 microm) using acetonitrile-water-formic acid (75:25:1, v/v/v) mobile phase. The retention times were approximately 1.8 min for both ketoconazole and the I.S. The MS-MS detection was by monitoring 531.2-->82.1 (m/z) for ketoconazole, and 733.5-->460.2 (m/z) for the I.S. The dynamic range was from 20.0 to 10000 ng/ml based on 0.1 ml plasma, with linear correlation coefficient of > or =0.9985. The run time was 2.5 min/injection. The recoveries of ketoconazole and the I.S. were 102 and 106%, respectively. The precision and accuracy of the control samples were with the relative standard deviations (RSDs) of < or =4.4% (n=6) and the relative errors (REs) from -0.6 to 1.4% for intra-day assay, and < or =8.6% RSD (n=18) and -1.4 to 0.9% RE for inter-day assay. The partial volume tests demonstrated good dilution integrity. Three freeze-thaw cycles, keeping plasma samples at ambient for 24 h, storing extracted samples at ambient for 24 h, and storing frozen plasma samples at approximately -20 degrees C for up to 2 months did not show substantial effects.  相似文献   

9.
A cyanobacterial bloom occurring in 1998 in lake Tres Pascualas (Concepción/Chile) was found to be dominated by Microcystis sp. The bloom contained both non-toxic (cyanopeptolin-type) and hepatotoxic (microcystin-type) peptides. Cyanopeptolin structure of the non-toxic peptides (called cyanopeptolin VW-1 and VW-2, respectively) was revealed by matrix assisted laser desorption ionization mass spectrometry (MALDI-TOF-MS) of whole cells, showing dominant molecular ions at m/z = 975 and m/z 995, respectively. On post source decay (PSD), both cyanopeptolins showed fragments deriving from Ahp-Phe-MTyr (3-amino-6-hydroxy-2-piperidone), the characteristic partial structure of cyanopeptolins. The amounts of each of the two cyanopeptolins could only roughly be estimated to be >0.1% of bloom material dry weight. In addition the blooms contained microcystins (20 microg/g bloom dry weight as determined by RP-HPLC, 13 microg/g according to ELISA determination). MALDI-TOF-MS revealed several structural variants of microcystin: MCYST-RR (microcystin with Arg and Arg, indicated by m/z 1,038 and confirmed by PSD revealing a m/z = 135 fragment deriving from the Adda side chain, MCYST-FR (microcystin with Phe and Arg, indicated by m/z = 1,015). The presence of [Asp(3)]-MCYST-LR (microcystin with Leu and Arg, Asp non-methylated, indicated by m/z 981), and [Asp(3)]-MCYST-YR (microcystin with Tyr and Arg, Asp non-methylated, indicated by m/z 1,031) were likely. The relative amounts of the peptides varied between February, April, and May. Whole cell extracts from the bloom material revealed specific enzyme inhibitory activities. The serin-proteases trypsin, plasmin, elastase were inhibited, assumable due to the cyanopeptolins found. Elastase and the cysteine-protease papain were not inhibited, inhibitions of protein kinase and glutathione S-transferase (GST) were low. Strong inhibition was observed with protein-phosphatase-1, likely due to the microcystins present in the samples.  相似文献   

10.
Among antitumor oxazaphosphorine drugs, the prodrug ifosfamide (IFO) and its analogs require metabolic activation by specific liver cytochrome P450 (CYP) enzymes to become therapeutically active. New 7,9-dimethyl-ifosfamide analogs have shown greater cytotoxic activity than IFO, whereas side-chain oxidation still occurred leading to monochloroacetone after N-dechloropropylation. A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed and validated for the simultaneous quantitation of the prodrug 7S,9S-dimethyl-ifosfamide (diMeIFO) and its two inactive metabolites, N(2)- and N(3)-deschloropropyl-dimethylifosfamide (N(2)-DCP-diMeIFO and N(3)-DCP-diMeIFO) in mouse plasma. After protein precipitation with methanol, the analytes were separated by isocratic reversed-phase chromatography with (methanol/ammonium formate pH 5.5, 60:40, v/v) and detected by tandem mass spectrometry using multiple reaction monitoring of transitions ions m/z 289→168 for diMeIFO, m/z 213→168 for N(2)-DCP-diMeIFO, m/z 213→92 for N(3)-DCP-diMeIFO and m/z 261→154 for IFO (internal standard). The calibration curves were linear over the concentration range of 20-10,000ng/mL for the three analytes. Mean extraction recoveries from mouse plasma were 99, 96, 99 and 100% for diMeIFO, N(2)-DCP-diMeIFO, N(3)-DCP-diMeIFO and IFO, respectively. The lower limit of quantitation for diMeIFO and its metabolites was 20 ng/mL in 50 μL plasma. The method was accurate with calculated bias from -5.8 to 4.0% for diMeIFO, from -1.1 to 10.6% for N(2)-DCP-diMeIFO and from -6.9 to 9.8% for N(3)-DCP-diMeIFO, and precise with coefficients of variation lower than 6.8%, 7.8% and 14.3%, respectively. The assay was successfully applied to a preliminary pharmacokinetic study of diMeIFO and of its metabolites in mice.  相似文献   

11.
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with electrospray ionization (ESI) was developed and validated for the simultaneous determination of pitavastatin and its lactone in human plasma and urine. Following a liquid-liquid extraction, both the analytes and internal standard racemic i-prolact were separated on a BDS Hypersil C(8) column, using methanol-0.2% acetic acid in water (70: 30, v/v) as the mobile phase. The mass spectrometer was operated in multiple reaction monitoring (MRM) mode using the transition m/z 422.4-->m/z 290.3 for pitavastatin, m/z 404.3-->m/z 290.3 for pitavastatin lactone and m/z 406.3-->m/z 318.3 for the internal standard, respectively. Linear calibration curves of pitavastatin and its lactone were obtained in the concentration range of 1-200 ng/ml, with a lower limit of quantitation of 1 ng/ml. The intra- and inter-day precision values were less than 4.2%, and accuracies were between -8.1 and 3.5% for both analytes. The proposed method was utilized to support clinical pharmacokinetic studies of pitavastatin in healthy subjects following oral administration.  相似文献   

12.
We previously reported that human blood platelets are directly stimulated by endotoxic Lipid A via the protein kinase C pathway (Grabarek, J., Timmons, S., and Hawiger, J. (1988) J. Clin. Invest. 82, 964-971). To study the relationship between the molecular structure of Lipid A and its ability to activate human platelets, we used Lipid A homologs derived from Salmonella minnesota Re595 lipopolysaccharide. Preparations of Lipid A are heterogeneous in regard to the degree of substitution of fatty acids which result in multiple homologs. These were separated by thin-layer chromatography and characterized by fast atom bombardment spectroscopy and related techniques (Johnson R. S., Her, G.-R., Grabarek, J., Hawiger, J., and Reinhold, V. N. (1990) J. Biol. Chem. 265, 8108-8116). The homologs of monophosphoryl Lipid A (MLA) present in fractions TLC-8 (heptaacyl MLA ion, m/z 1953), TLC-7 (three hexaacyl species with predominant MLA ion m/z 1715), and TLC-6 (four pentaacyl homologs with predominant MLA ion, m/z 1505) induced secretion of [14C]serotonin and aggregation of platelets. Lipid A homologs in fractions TLC-5 (three tetraacyl MLA ions, m/z 1323, 1307, and 1279), TLC-4 (one major triacyl MLA ion, m/z 1097), TLC-3 (tetraacyl MLA ion, m/z 1278), TLC-2 (a diphosphoryl hexaacyl Lipid A ion, m/z 1795, and several ions of low abundance), and TLC-1 (two ions, m/z 1097 and 666) were not active in regard to human platelet aggregation and [14C]serotonin secretion. The most active homolog was heptaacyl MLA ion, m/z 1953, present in TLC-8, while homologs present in TLC-7 and TLC-6 were 5 and 10 times less active, respectively. Rapid phosphorylation of a human platelet protein of Mr 40,000-47,000 (P47), a substrate for protein kinase C activation, preceded secretion of serotonin when platelets were triggered by the most active heptaacyl MLA ion, m/z 1953. These events were time-dependent, with half-maximal response of phosphorylation of P47 at 30 s and [14C]serotonin secretion at 45 s. A marked difference in the degree of phosphorylation of P47 was observed with heptaacyl MLA homolog present in TLC-8 inducing complete phosphorylation (97%), whereas less acylated Lipid A homologs present in TLC-1 caused marginal phosphorylation (20%). These results indicate that the degree of acylation of monophosphoryl Lipid A determines its functional properties toward human platelets in regard to secretion of [14C]serotonin, aggregation, and activation of protein kinase C.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

13.
An ammonium-adduct based liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous determination of three isomeric metabolites of tacrolimus (FK506), 13-O-demethylated (M1), 31-O-demethylated (M2) and 15-O-demethylated (M3) tacrolimus in human whole blood and plasma. These metabolites and the internal standards were extracted from biological matrix by methylbutyl ether (MTBE). Separation was achieved on a Genesis C(18) column with a gradient mobile phase elution. Ammonium-adduct ions formed by a Turbo Ionspray in positive ion mode were used to detect each analyte and internal standard. The MS/MS detection was by monitoring the fragmentation of 807.5-->772.4 (m/z) for M1, 807.5-->754.5 (m/z) for both M2 and M3, 795.5-->760.5 (m/z) for IS1 (FR298701) and 961.5-->908.5 (m/z) for IS2 (FR290198) on a triple quadrupole mass spectrometer (Sciex API 3000). The retention times were approximately 4.1 min for M1, 6.8 min for M2, 6.0 min for M3, and 3.9 min for IS1 and 6.4 min for IS2, respectively. The validated dynamic range was 0.2-20 ng/ml for all three metabolites based on a sample volume of 0.25-ml. The linearity of calibration curves for M1, M2, and M3 in both matrices had a correlation coefficient of >/=0.9984. In whole blood, validation data showed intra-batch (n=6) CVs of 相似文献   

14.
A sensitive high-performance liquid chromatography-tandem mass spectrometry assay for thiocoraline, an anti-tumor depsipeptide, in mouse plasma is described. Echinomycin, a quinoxaline peptide, was used as an internal standard. Thiocoraline was recovered from the mouse plasma using protein precipitation with acetonitrile and followed by solid-phase extraction of the supernatant. The mobile phase consisted of methanol (0.1% formic acid)-water (0.1% formic acid) (90:10, v/v). The analytical column was a YMC C(18). The standard curve was linear from 0.1 to 50 ng/ml (R(2)>0.99). The lower limit of quantitation was 0.1 ng/ml. The assay was specific based on the multiple reaction monitoring transitions at m/z 1157-->215 and m/z 1101-->243 for thiocoraline and the internal standard, echinomycin, respectively. The mean intra- and inter-day assay accuracies remained below 5 and 12%, respectively, for all calibration standards and quality control (QC) samples. The intra- and inter-day assay precisions were less than 11.4 and 9.5% for all QC levels, respectively. The utility of the assay was demonstrated by a pharmacokinetic study of i.v. (bolus) thiocoraline on CD-1 mice. Thiocoraline was stable in mouse plasma in an ice-water bath for 6 h and for three freeze-thaw cycles. The reconstituted thiocoraline after extraction and drying sample process was stable in the autosampler for over 24 h. The assay was able to quantify thiocoraline in plasma up to 48 h following dose. Pharmacokinetic analysis showed that thiocoraline has distinct pharmacokinetic profiling when dosed in different formulation solutions. The assay is currently used to measure thiocoraline plasma concentrations in support of a project to develop a suitable formulation with a desirable pharmacokinetic profile.  相似文献   

15.
Vinorelbine is a semi-synthetic vinca alkaloid with demonstrated high activities against various types of advanced cancer. To support a clinical pharmacokinetic study, a simple, rapid and sensitive method to determine vinorelbine in human plasma was developed using reversed phase liquid chromatography (LC) coupled with electrospray ionization mass spectrometry/mass spectrometry (ESI-MS/MS). Vinorelbine and vinblastine (the internal standard) were extracted from human plasma by one-step liquid-liquid extraction (LLE) with methyl-t-butyl ether. The chromatographic separation was achieved on a Spursil polar-modified C(18) column (50 mm×2.1 mm, 3 μm, Dikma Technologies) with an isocratic mobile phase of a 75:25 (v/v) acetonitrile-4 mmol/L ammonium formate (pH 3.0) mixture at a flow-rate of 0.4 mL/min. The MS/MS detection was performed in the positive ion multiple reaction monitoring (MRM) mode by monitoring the precursor→product ion transitions at m/z 779.4→122.0 and m/z 811.3→224.2 for vinorelbine and the internal standard, respectively. The assay was validated in the range 0.1-200 ng/mL (r>0.997), the lowest level of this range being the lower limit of quantification (LLOQ) based on 50 μL of plasma. The intra- and inter-day precisions were within 6.0%, while the accuracy was within ±4.7% of nominal values. Detection and quantification of both analytes within 2 min make this method suitable for high-throughput analyses. The method was successfully applied to evaluate the systemic pharmacokinetics of vinorelbine after a 20-min intravenous infusion of 25 mg/m(2) of vinorelbine to patients with metastatic breast cancer.  相似文献   

16.
A sensitive and rapid LC-MS/MS method was developed and validated for the determination of levamisole in human plasma. The assay was based on liquid-liquid extraction of analytes from human plasma with ethyl ether. Chromatographic separation was carried on an Agilent HC-C(8) column (150 mm × 4.6 mm, 5 μm) at 40°C, with a mobile phase consisting of acetonitrile-10 mM ammonium acetate (70:30, v/v), a flow rate of 0.5 mL/min and a total run time of 6 min. Detection and quantification were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 205.1→178.2 for levamisole, and m/z 296.1→264.1 for mebendazole (internal standard). The assay was linear over a concentration range of 0.1-30 ng/mL with a lower limit of quantification of 0.1 ng/mL. The coefficient of variation of the assay precision was less than 8.5%. The assay was successfully used to analyze human plasma samples in a pharmacokinetic study where levamisole was administered as a liniment.  相似文献   

17.
The immunosuppressant drug mycophenolic acid (MPA) and its major metabolite, mycophenolic acid glucuronide (MPAG), are highly bound to albumin. An HPLC-tandem-MS (HPLC/MS/MS) and an HPLC-UV assay were developed to measure free (unbound) concentrations of MPA and MPAG, respectively. Ultrafiltrate was prepared from plasma (500 microl) by ultrafiltration at 3000 x g for 20 min (20 degrees C). Both MPA and MPAG were isolated from ultrafiltrate (100 microl) by acidification and C18 solid-phase extraction. Free MPA was measured by electrospray tandem mass spectrometry using selected reactant monitoring (MPA: m/z 338.2--> 206.9) in positive ionisation mode. Chromatography was performed on a PFPP column (50 mm x 2 mm, 5 microm). Total analysis time was 7 min. The assay was linear over the range 1-200 microg/l with a limit of quantification of 1 microg/l. The inter-day accuracy and imprecision of quality controls (7.5, 40, 150 microg/l) were 94-99% and < 7%, respectively. Free MPAG was chromatographed on a C18 Nova-Pak column (150 mm x 3.9 mm, 5 microm) using a binary gradient over 20 min. The eluent was monitored at 254 nm. The assay was linear over the range 1-50 mg/l with the limit of quantification at 2.5 mg/l. The inter-day accuracy and imprecision of quality controls (5, 20, 45 mg/l) was 101-107% and < 8% (n = 4), respectively. For both methods no interfering substances were found in ultrafiltrate from patients not receiving MPA. The methods described have a suitable dynamic linear range to facilitate the investigation of free MPA and MPAG pharmacokinetics in transplant patients. Further, this is the first reported HPLC-UV method to determine free MPAG concentrations.  相似文献   

18.
We determined cabergoline and L-dopa in human plasma using liquid chromatography-mass spectrometry with tandem mass spectrometry (LC-MS-MS). The deproteinized plasma samples with organic solvent or acid were analyzed directly by reversed-phase liquid chromatography. Using multiple reaction monitoring (MRM, product ions m/z 381 of m/z 452 for cabergoline and m/z 152 of m/z 198 for L-dopa) on LC-MS-MS with electrospray ionization (ESI), cabergoline and L-dopa in human plasma were determined. Calibration curves of the method showed a good linearity in the range 5-250 pg/ml for cabergoline and 1-200 ng/ml for L-dopa, respectively. The limit of determination was estimated to be approximately 2 pg/ml for cabergoline and approximately 0.1 ng/ml for L-dopa, respectively. The method was applied to the analysis of cabergoline and L-dopa in plasma samples from patients treated with these drugs. The precision of analysis showed coefficients of variation ranging from 3.8% to 10.5% at cabergoline concentration of 13.8-26.2 pg/ml and from 2.9% to 8.9% at an L-dopa concentration of 302.5-522.1 ng/ml in patient plasma. As a result, the procedure proved to be very suitable for routine analysis.  相似文献   

19.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometry method is described for the simultaneous determination of nebivolol and valsartan in human plasma. Nebivolol and valsartan were extracted from plasma using acetonitrile and separated on a C18 column. The mobile phase consisting of a mixture of acetonitrile and 0.05 mM formic acid (50:50 v/v, pH 3.5) was delivered at a flow rate of 0.25 ml/min. Atmospheric pressure ionization (API) source was operated in both positive and negative ion mode for nebivolol and valsartan, respectively. Selected reaction monitoring mode (SRM) using the transitions of m/z 406.1-->m/z 150.9; m/z 434.2-->m/z 179.0 and m/z 409.4-->m/z 228.1 were used to quantify nebivolol, valsartan and internal standard (IS), respectively. The linearity was obtained over the concentration range of 0.01-50.0 ng/ml and 1.0-2000.0 ng/ml and the lower limits of quantitation were 0.01 ng/ml and 1.0 ng/ml for nebivolol and valsartan, respectively. This method was successfully applied to the pharmacokinetic study of fixed dose combination (FDC) of nebivolol and valsartan formulation product after an oral administration to healthy human subjects.  相似文献   

20.
An analytical method based upon liquid chromatography coupled to ion trap mass spectrometry (MS) detection with electrospray ionization interface has been developed for the simultaneous identification and quantification of droperidol and ondansetron in human plasma. The two drugs were isolated from 0.5 mL of plasma using a basic liquid-liquid extraction with diethyl ether/heptane (90/10, v/v) and tropisetron and haloperidol as internal standards, with satisfactory extraction recoveries. They were separated on a 5-μm C(18) Highpurity column (150 mm×2.1 mm I.D.) maintained at 30°C. The elution was achieved isocratically with a mobile phase of 2 mM HCOONH(4) pH 3.8 buffer/acetonitrile (60/40, v/v) at a flow rate of 200 μL/min. Data were collected either in full-scan MS mode at m/z 100-450 or in full-scan MS-MS mode, selecting the [M+H] (+) ion at m/z=294.0 for ondansetron, m/z=285.2 for tropisetron, m/z=380.0 for droperidol and m/z=376.0 for haloperidol. The most intense daughter ion of ondansetron (m/z=212.0) and droperidol (m/z=194.0) were used for quantification. Retention times for tropisetron, ondansetron, droperidol and haloperidol were 2.50, 2.61, 3.10 and 4.68 min, respectively. Calibration curves were linear for both compounds in the 0.50-500 ng/mL range. The limits of detection and quantification were 0.10 ng/mL and 0.50 ng/mL, respectively. The intra- and inter-assay precisions were lower than 6.4% and intra- and inter-assay recoveries were in the 97.6-101.9% range for the three 3, 30 and 300 ng/mL concentrations. This method allows simultaneous and rapid measurement of droperidol and ondansetron, which are frequently co-administrated for the prevention of postoperative nausea and vomiting.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号