首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The analysis of PTMs such as phosphorylation has become an important field in MS because they can directly indicate protein states and interactions. Whereas the characterization of singly and doubly phosphorylated peptides has almost become routine, identifying phosphorylation events at multiple residues within a small region of a protein is still problematic. The identification of multiple modifications can be further hampered by low sequence information due to multiple neutral losses from phosphorylated side chains. Here we present a strategy for the analysis of complex phosphopeptides that combines peptide enrichment by titanium dioxide, separation by RP separation on monolithic columns and MS using high energy HE-CAD in a MALDI TOF/TOF analyser. Using synthetic phosphopeptides our approach is compared to multistage activation (MSA) MS/MS and the recently described electron transfer dissociation (ETD) method using an ESI-LTQ mass spectrometer.  相似文献   

2.
The RuvABC resolvasome of Escherichia coli typifies nucleoprotein complexes involved in genetic transactions. This molecular assembly catalyses the resolution of Holliday junctions that arise during genetic recombination and DNA repair. This process involves two key steps: branch migration, catalysed by the RuvB protein that is targeted to the Holliday junction by the structure specific RuvA protein, and resolution, which is catalysed by the RuvC endonuclease. We have used matrix-assisted laser desorption/ionisation time of flight mass spectrometry (MALDI-TOF MS) to rapidly identify the binding of RuvA to an immobilised synthetic Holliday junction; unambiguous identification was verified using tryptic digest of the bound protein. In conjunction with a novel fluorescent-based technique incorporating ion pair reverse phase liquid chromatography, a "footprint" of the RuvA:Holliday complex was obtained. These two complementary techniques offer a generic approach to the analysis of nucleoprotein complexes.  相似文献   

3.
Previous studies in our group have shown that the analyte signal in a matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) experiment is strongly influenced by the binding interactions between the target surface and the analyte. Specifically, the analyte signal increases with decreases in surface binding affinity, which has been attributed to more unbound analyte being available for incorporation within the MALDI matrix. In this work, polyethylene glycol (PEG) was chemically grafted onto a polyurethane (PU) film to produce a MALDI target having reduced surface-protein binding affinity, and the effect of this modification on protein MALDI ion signals was investigated. The proteins myoglobin, lysozyme, and albumin were used to evaluate the PEG PU modified target as compared with a PU target and a commercial stainless steel target. It is shown that there are enhancements in the protein MALDI ion signals on the PEG PU modified target and that the limit of detection for these proteins is decreased by a factor of 2 to 6 in comparison with the unmodified PU and the commercial stainless steel targets.  相似文献   

4.

Background  

Unravelling the serum proteome is the subject of intensified research. In this regard, two-dimensional electrophoresis coupled with MALDI MS analysis is still one of the most commonly used method. Despite some improvements, there is the need for better protocols to enable comprehensive identification of serum proteins.  相似文献   

5.
The applicability of the less specific protease elastase for the identification of membrane and cytosolic proteins has already been demonstrated. MALDI as ionization technique particularly favors the detection of basic and to a lesser extent of weakly acidic peptides, whereas neutral peptides often remain undetected. Moreover, peptides below 700 Da are routinely excluded. In the following study, the advantage of additional information gained from tandem mass tag zero labeled peptides and the resultant increase in sequence coverage was evaluated. Through derivatization with tandem mass tag reagents, peptide measurement within the standard mass range of the MALDI reflector mode is achievable due to the mass increase. Compared to the unlabeled sample, peptides exhibiting relatively low molecular masses, pI values or higher hydrophobicity could be identified.  相似文献   

6.
The curved-field reflectron (CFR), when used as the second mass analyzer in a tandem time-of-flight mass spectrometer, provides a design that enables the use of very high energy collision-induced dissociation (CID). Specifically, this is because the wide energy bandwidth of the CFR obviates the need for floating the collision region to decelerate the precursor ions and subsequently reaccelerating product ions to enable reflectron focusing. Here we describe the evolution of tandem instruments based on the CFR, from its introduction in 1993 to the current commercial TOF(2) mass spectrometer from Shimadzu Corporation, and briefly review the history of TOF/TOF instruments. A number of applications are also described. One is the characterization of a C-terminal cleavage of cystatin C that appears to be associated with patients with remitting relapse multiple sclerosis (RRMS). Both surface-enhanced laser desorption/ionization (SELDI) and MALDI were used on a high performance TOF instrument operating in the MS and MS/MS modes. Tandem TOF mass spectrometry has also been used to determine the acetylation sites on histones and on the enzyme, histone acetyl transferase (HAT), responsible for the modification. Acetylation has been determined quantitatively for multiple sites on histone H3 and H4 using a deuteroacetylation method. For a number of closely spaced sites on the histone tail regions, MS/MS enables us to then determine both the order and distribution of acetylation.  相似文献   

7.
8.
Reversible phosphorylation is one of the most important posttranslational modifications of cellular proteins. Mass spectrometry is a widely used technique in the characterization of phosphorylated proteins and peptides. Similar to nonmodified peptides, sequence information for phosphopeptides digested from proteins can be obtained by tandem mass analysis using either electrospray ionization or matrix assisted laser desorption/ionization (MALDI) mass spectrometry. However, the facile loss of neutral phosphoric acid (H3PO4) or HPO3 from precursor ions and fragment ions hampers the precise determination of phosphorylation site, particularly if more than one potential phosphorylation site or concensus sequence is present in a given tryptic peptide. Here, we investigated the fragmentation of phosphorylated peptides under laser-induced dissociation (LID) using a MALDI-time-of-flight mass spectrometer with a curved-field reflectron. Our data demonstrated that intact fragments bearing phosphorylated residues were produced from all tested peptides that contain at least one and up to four phosphorylation sites at serine, threonine, or tyrosine residues. In addition, the LID of phosphopeptides derivatized by N-terminal sulfonation yields simplified MS/MS spectra, suggesting the combination of these two types of spectra could provide an effective approach to the characterization of proteins modified by phosphorylation.  相似文献   

9.
A high-molecular-mass polysaccharide galactan (M 2000 kDa) was isolated from flax at the stage of cell wall thickening of the bast fiber development. The polymer structure was studied by 1H NMR spectroscopy and MALDI TOF mass spectrometry. It is built up of Gal (59%), Rha (15%), GalA (23%), and Ara (3%) residues. The galactan backbone consists of successively alternating monomer disaccharide units (→ 4GalA1 → 2Rha1 →)n and is similar in its structure to the backbone of rhamnogalacturonan-1 (RG-I). Rhamnose residues bear in position 4 β-(1 → 4)-galactose side chains of various lengths with a polymerization degree of up to 28 or higher. A part of the side chains have branchings.  相似文献   

10.
Yu SY  Wu SW  Khoo KH 《Glycoconjugate journal》2006,23(5-6):355-369
Concerted MALDI-MS profiling and CID MS/MS sequencing of permethylated glycans is one of the most effective approaches for high throughput glycomics applications. In essence, the identification of larger complex type N-glycans necessitates an unambiguous definition of any modification on the trimannosyl core and the complement of non-reducing terminal sequences which constitute the respective antennary structures. Permethylation not only affords analyses of both neutral and sialylated glycans at comparable ease and sensitivity but also yields more sequence-informative fragmentation pattern. Facile glycosidic cleavages directed mostly at N-acetylglucosamine under low energy CID, as implemented on a quadrupole/time-of-flight (Q/TOF) instrument, often afford multiple losses of the attached antenna resulting in characteristic ions related to the number of antennary branches on the trimannosyl core. Non-reducing terminal epitopes can be easily deduced but information on the linkage specific substituent on the terminal units is often missing. The high energy CID MS/MS afforded by TOF/TOF instrument can fill in the gap by giving an array of additional cross-ring and satellite ions. Glycosidic cleavages occurring specifically in concert with loss of 2-linked or 3-linked substituents provide an effective way to identify the branch-specific antennary extension. These characteristics are shown here to be effective in deriving the sequences of additionally galactosylated, sialylated and fucosylated terminal N-acetyllactosamine units and their antennary location. Together, a highly reproducible fragmentation pattern can be formulated to simplify spectral assignment. This work also provides first real examples of sequencing multiply sialylated complex type N-glycans by high energy CID on a TOF/TOF instrument. Shin-Yi Yu and Sz-Wei Wu contributed equally to this work. Dedicated to the late Prof. Yasuo Inoue, without whom the body of work represented by this article would not have been initiated in Taiwan.  相似文献   

11.
An enzymatic microreactor with a volume of 470 nL has been prepared by immobilizing trypsin on a 10 cm long reactive porous polymer monolith located in a 100 microm i.d. fused silica capillary. This reactor affords suitable degrees of digestion of proteins even after very short residence times of less than 1 min. The performance is demonstrated with the digestion of eight proteins ranging in molecular mass from 2848 to 77 754. The digests were analyzed using mass spectrometry in two modes: off-line MALDI and in-line nanoelectrospray ionization. The large numbers of identified peptides enable a high degree of sequence coverage and positive identification of the proteins. The extent of sequence coverage decreases as the molecular mass of the digested protein increases.  相似文献   

12.
13.
Single nucleotide polymorphisms (SNPs) are now widely used for many DNA analysis applications such as linkage disequilibrium mapping, pharmacogenomics and traceability. Many methods for SNP genotyping exist with diverse strategies for allele-distinction. Mass spectrometers are used most commonly in conjunction with primer extension procedures with allele-specific termination. Here we present a novel concept for allele-preparation for SNP genotyping. Primer extension is carried out with an extension primer positioned immediately upstream of the SNP that is to be genotyped, a complete set of four ribonucleotides and a ribonucleotide incorporating DNA polymerase. The allele-extension products are then treated with alkali, which results in the cleavage immediately after the first added ribonucleotide. In addition, to obtain fragments easily detectable by mass spectrometry, we have included a ribonucleotide in the primer usually at the fourth nucleotide from the 3′ terminus. The method was tested on four SNPs each with a different combination of nucleotides. The advantage over other mass spectrometry-based SNP genotyping assays is that this one only requires a PCR, a primer extension reaction with a universal extension mix and an inexpensive facile cleavage reaction, which makes it overall very cost effective and easy in handling.  相似文献   

14.
Cyclotides are a very abundant class of plant peptides that display significant sequence variability around a conserved cystine-knot motif and a head-to-tail cyclized backbone conferring them with remarkable stability. Their intrinsic bioactivities combined with tools of peptide engineering make cyclotides an interesting template for the design of novel agrochemicals and pharmaceuticals. However, laborious isolation and purification prior to de novo sequencing limits their discovery and hence their use as scaffolds for peptide-based drug development. Here we extend the knowledge about their sequence diversity by analysing the cyclotide content of a violet species native to Western Asia and the Caucasus region. Using an experimental approach, which was named sequence fragment assembly by MALDI-TOF/TOF, it was possible to characterize 13 cyclotides from Viola ignobilis, whereof ten (vigno 1–10) display previously unknown sequences. Amino acid sequencing of various enzymatic digests of cyclotides allowed the accurate assembly and alignment of smaller fragments to elucidate their primary structure, even when analysing mixtures containing multiple peptides. As a model to further dissect the combinatorial nature of the cyclotide scaffold, we employed in vitro oxidative refolding of representative vigno cyclotides and confirmed the high dependency of folding yield on the inter-cysteine loop sequences. Overall this work highlights the immense structural diversity and plasticity of the unique cyclotide framework. The presented approach for the sequence analysis of peptide mixtures facilitates and accelerates the discovery of novel plant cyclotides.  相似文献   

15.
16.
The objective of this study was to develop a mass spectrometric protocol to search for proteins related to phototrophy in marine bacteria. The genes that produce proteins involved in conversion of light into energy have been detected by cloning-sequencing from some of these bacteria, but it was previously unknown if these proteins were actually expressed. Attaining this study's goal was complicated by the fact that the samples consisted of miniscule cell pellets, which yielded small amounts of very complex mixtures of proteins. Sample preparation and analysis were tailored to optimize the probability of detecting the proteins of interest. It has been reported that using both matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) to analyze a mixture of peptides leads to the identification of more peptides that either technique alone. In order to exploit this complementarity between ESI and MALDI for proteomic analysis, samples were analyzed using both ionization techniques. With correct choices in sample preparation and ionization process, biologically relevant proteins can be identified out of small samples containing whole proteomes.  相似文献   

17.
It was shown that matrix-assisted laser desorption/ionization (MALDI) mass spectrometry could be used for the diagnostic characterization of propionic acid bacteria (PABs). The spectra of proteins (whole PAB cells) with a molecular mass of 3000 to 11 000 were obtained and analyzed using three matrices: sinapinic (SA), 2,5-dihydroxibenzoic (DHB), and α-cyano-4-hydroxycinnamic acid (HCCA). The MALDI spectra of PAB revealed the protein peaks characteristic of (1) the genus Propionibacterium (3496, 5386, 5605, 10 470), (2) the groups of species sharing the common composition of their cell walls and fatty acids, and (3) a species (four species were investigated). Exemplified by the P. shermanii strains (the collection and mutant ones) producing and not producing vitamin B12, the possibility of using MALDI profiles for strain differentiation was confirmed. The MALDI profiles of the propionic acid cocci of the genus Luteococcus differ substantially from the profiles of PAB strains of the genus Propionibacterium, which is an additional proof of the validity of whole-cell MALDI spectra for generic differentiation of bacteria. Our investigation shows that the bacterial groups determined using the MALDI profiles correlate with the phylogenetic 16S rRNA gene groups, thus demonstrating the high resolution of this method for the differentiation of intraspecific differences (subspecies, strains).  相似文献   

18.
BACKGROUND: MALDI-TOF-MS has become an important analytical tool in the identification of proteins and evaluation of their role in biological processes. A typical protocol consists of sample purification, separation of proteins by 2D-PAGE, enzymatic digestion and identification of proteins by peptide mass fingerprint. Unfortunately, this approach is not appropriate for the identification of membrane or low or high pI proteins. An alternative technique uses 1D-PAGE, which results in a mixture of proteins in each gel band. The direct analysis of the proteolytic digestion of this mixture is often problematic because of poor peptide detection and consequent poor sequence coverage in databases. Sequence coverage can be improved through the combination of several matrices. RESULTS: The aim of this study was to trust the MALDI analysis of complex biological samples, in order to identify proteins that interact with the membrane network of keratinocytes. Peptides obtained from protein trypsin digestions may have either hydrophobic or hydrophilic sections, in which case, the direct analysis of such a mixture by MALDI does not allow desorbing of all peptides. In this work, MALDI/MS experiments were thus performed using four different matrices in concert. The data were analysed with three algorithms in order to test each of them. We observed that the use of at least two matrices in concert leads to a twofold increase of the coverage of each protein. Considering data obtained in this study, we recommend the use of HCCA in concert with the SA matrix in order to obtain a good coverage of hydrophilic proteins, and DHB in concert with the SA matrix to obtain a good coverage of hydrophobic proteins. CONCLUSION: In this work, experiments were performed directly on complex biological samples, in order to see systematic comparison between different matrices for real-life samples and to show a correlation that will be applicable to similar studies. When 1D gel is needed, each band may contain a great number of proteins, each present in small amounts. To improve the proteins coverage, we have performed experiments with some matrices in concert. These experiments enabled reliable identification of proteins, without the use of Nanospray MS/MS experiments.  相似文献   

19.
Targeted quantitative proteomics by mass spectrometry aims to selectively detect one or a panel of peptides/proteins in a complex sample and is particularly appealing for novel biomarker verification/validation because it does not require specific antibodies. Here, we demonstrated the application of targeted quantitative proteomics in searching, identifying, and quantifying selected peptides in human cerebrospinal spinal fluid (CSF) using a matrix-assisted laser desorption/ionization time-of-flight tandem mass spectrometer (MALDI TOF/TOF)-based platform. The approach involved two major components: the use of isotopic-labeled synthetic peptides as references for targeted identification and quantification and a highly selective mass spectrometric analysis based on the unique characteristics of the MALDI instrument. The platform provides high confidence for targeted peptide detection in a complex system and can potentially be developed into a high-throughput system. Using the liquid chromatography (LC) MALDI TOF/TOF platform and the complementary identification strategy, we were able to selectively identify and quantify a panel of targeted peptides in the whole proteome of CSF without prior depletion of abundant proteins. The effectiveness and robustness of the approach associated with different sample complexity, sample preparation strategies, as well as mass spectrometric quantification were evaluated. Other issues related to chromatography separation and the feasibility for high-throughput analysis were also discussed. Finally, we applied targeted quantitative proteomics to analyze a subset of previously identified candidate markers in CSF samples of patients with Parkinson's disease (PD) at different stages and Alzheimer's disease (AD) along with normal controls.  相似文献   

20.
The 2-nitrobenzenesulfenyl (NBS) method, which is useful for quantitative proteome analysis, is based on stable isotope labeling of tryptophan residues with NBS chloride ((12)C(6)-NBSCl or (13)C(6)-NBSCl). We found that 3-hydroxy-4-nitrobenzoic acid (3H4NBA) is a more suitable matrix than 2,5-dihydroxybenzoic acid (DHB) for detecting NBS-labeled peptides by MALDI-quadrupole IT (QIT)-TOF MS . Furthermore, NBS-labeled peptides were selectively ionized and detected in a mixture of NBS-labeled and unlabeled peptides. Labeled paired peaks were easily detected without enrichment, nonpaired labeled peaks were clearly distinguished from unlabeled contaminating peptides, and nitrotyrosine-containing peptides were also selectively detected on the 3H4NBA matrix, while by-product-peaks arising from nitrobenzene moieties were suppressed. The use of 3H4NBA as a comatrix with CHCA improved the sensitivity of detection while substantially retaining the selectivity of 3H4NBA. The 3H4NBA matrix offers great advantages in terms of simplicity, sensitivity, and usability when used for the NBS method and for MALDI-TOF MS analysis applied to compounds having a nitrobenzene ring.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号